All Devices and Entities

please read

Make sure you have read and understood the Disclaimer before sending ambiguous messages to your EMS bus as you could cause serious damage to your equipment.

Most Bosch branded boilers that support the Logamatic EMS bus protocols work with this design. This includes Nefit, Buderus, Worcester, Junkers and Sieger (all copyrighted).

EMS devices are being constantly added to the database on each new release.

The following device types are supported:

  • boiler
  • thermostat
  • heatpump
  • heatsource
  • solar
  • connect
  • mixer
  • controller
  • switch
  • gateway
  • alert
  • pump

All EMS Telegrams~

Download the full CSV file

telegram_type_id name is_fetched is_cmd
0x04 UBAFactory fetched cmd
0x06 RCTime cmd
0x0A EasyMonitor fetched cmd
0x10 UBAErrorMessage1 cmd
0x11 UBAErrorMessage2 cmd
0x12 RCErrorMessage cmd
0x13 RCErrorMessage2 cmd
0x14 UBATotalUptime fetched cmd
0x15 UBAMaintenanceData cmd
0x16 UBAParameters fetched cmd
0x18 UBAMonitorFast cmd
0x19 UBAMonitorSlow cmd
0x1A UBASetPoints cmd
0x1C UBAMaintenanceStatus cmd
0x1E WM10TempMessage cmd
0x23 JunkersSetMixer fetched cmd
0x26 UBASettingsWW fetched cmd
0x28 WeatherComp fetched cmd
0x2A MC110Status cmd
0x2E Meters cmd
0x33 UBAParameterWW fetched cmd
0x34 UBAMonitorWW cmd
0x35 UBAFlags cmd
0x37 WWSettings fetched cmd
0x38 WWTimer fetched cmd
0x39 WWCircTimer fetched cmd
0x3A RC30WWSettings fetched cmd
0x3B Energy cmd
0x3D RC35Set cmd
0x3E RC35Monitor cmd
0x3F RC35Timer cmd
0x40 RC30Temp cmd
0x41 RC30Monitor cmd
0x42 RC35Timer2 cmd
0x47 RC35Set cmd
0x48 RC35Monitor cmd
0x49 RC35Timer cmd
0x4C RC35Timer2 cmd
0x51 RC35Set cmd
0x52 RC35Monitor cmd
0x53 RC35Timer cmd
0x56 RC35Timer2 cmd
0x5B RC35Set cmd
0x5C RC35Monitor cmd
0x5D RC35Timer cmd
0x60 RC35Timer2 cmd
0x96 SM10Config fetched cmd
0x97 SM10Monitor cmd
0x9C WM10MonitorMessage cmd
0x9D WM10SetMessage cmd
0xA2 RCError cmd
0xA3 RCOutdoorTemp cmd
0xA5 IBASettings fetched cmd
0xA7 RC30Set cmd
0xAA MMConfigMessage fetched cmd
0xAB MMStatusMessage cmd
0xAC MMSetMessage cmd
0xAF RC20Remote cmd
0xB0 RC10Set cmd
0xB1 RC10Monitor cmd
0xBB HybridSettings fetched cmd
0xBF ErrorMessage cmd
0xC2 UBAErrorMessage3 cmd
0xD1 UBAOutdoorTemp cmd
0xE3 UBAMonitorSlowPlus2 cmd
0xE4 UBAMonitorFastPlus cmd
0xE5 UBAMonitorSlowPlus cmd
0xE6 UBAParametersPlus fetched cmd
0xE9 UBAMonitorWWPlus cmd
0xEA UBAParameterWWPlus fetched cmd
0x0101 ISM1Set fetched cmd
0x0103 ISM1StatusMessage fetched cmd
0x0104 ISM2StatusMessage cmd
0x010C IPMStatusMessage cmd
0x011E IPMTempMessage cmd
0x0165 JunkersSet cmd
0x0166 JunkersSet cmd
0x0167 JunkersSet cmd
0x0168 JunkersSet cmd
0x016F JunkersMonitor cmd
0x0170 JunkersMonitor cmd
0x0171 JunkersMonitor cmd
0x0172 JunkersMonitor cmd
0x0179 JunkersSet cmd
0x017A JunkersSet cmd
0x017B JunkersSet cmd
0x017C JunkersSet cmd
0x01D3 JunkersDhw fetched cmd
0x023A RC300OutdoorTemp fetched cmd
0x023E PVSettings fetched cmd
0x0240 RC300Settings fetched cmd
0x0267 RC300Floordry cmd
0x0291 HPMode fetched cmd
0x0292 HPMode fetched cmd
0x0293 HPMode fetched cmd
0x0294 HPMode fetched cmd
0x029B RC300Curves cmd
0x029C RC300Curves cmd
0x029D RC300Curves cmd
0x029E RC300Curves cmd
0x029F RC300Curves cmd
0x02A0 RC300Curves cmd
0x02A1 RC300Curves cmd
0x02A2 RC300Curves cmd
0x02A5 RC300Monitor cmd
0x02A6 RC300Monitor cmd
0x02A7 CRFMonitor cmd
0x02A8 RC300Monitor cmd
0x02A9 RC300Monitor cmd
0x02AA RC300Monitor cmd
0x02AB RC300Monitor cmd
0x02AC RC300Monitor cmd
0x02AF RC300Summer cmd
0x02B0 RC300Summer cmd
0x02B1 RC300Summer cmd
0x02B2 RC300Summer cmd
0x02B3 RC300Summer cmd
0x02B4 RC300Summer cmd
0x02B5 RC300Summer cmd
0x02B6 RC300Summer cmd
0x02B9 RC300Set cmd
0x02BA RC300Set cmd
0x02BB RC300Set cmd
0x02BC RC300Set cmd
0x02BD RC300Set cmd
0x02BE RC300Set cmd
0x02BF RC300Set cmd
0x02C0 RC300Set cmd
0x02CC HPPressure fetched cmd
0x02CD MMPLUSSetMessage_HC fetched cmd
0x02CE RC300Set2 cmd
0x02D0 RC300Set2 cmd
0x02D2 RC300Set2 cmd
0x02D5 MMPLUSSetMessage_HC fetched cmd
0x02D7 MMPLUSStatusMessage_HC cmd
0x02DF MMPLUSStatusMessage_HC cmd
0x02F5 RC300WWmode fetched cmd
0x02F6 RC300WW2mode fetched cmd
0x031B RC300WWtemp fetched cmd
0x031D RC300WWmode2 cmd
0x031E RC300WWmode2 cmd
0x0358 SM100SystemConfig fetched cmd
0x035A SM100CircuitConfig fetched cmd
0x035C SM100HeatAssist fetched cmd
0x035D SM100Circuit2Config fetched cmd
0x035F SM100Config1 fetched cmd
0x0361 SM100Differential fetched cmd
0x0362 SM100Monitor cmd
0x0363 SM100Monitor2 cmd
0x0364 SM100Status cmd
0x0366 SM100Config cmd
0x036A SM100Status2 cmd
0x0380 SM100CollectorConfig fetched cmd
0x038E SM100Energy fetched cmd
0x0391 SM100Time fetched cmd
0x0467 HPSet cmd
0x0468 HPSet cmd
0x0469 HPSet cmd
0x046A HPSet cmd
0x0471 RC300Summer2 cmd
0x0472 RC300Summer2 cmd
0x0473 RC300Summer2 cmd
0x0474 RC300Summer2 cmd
0x0475 RC300Summer2 cmd
0x0476 RC300Summer2 cmd
0x0477 RC300Summer2 cmd
0x0478 RC300Summer2 cmd
0x047B HP2 cmd
0x0484 HPSilentMode fetched cmd
0x0485 HpCooling fetched cmd
0x0486 HpInConfig fetched cmd
0x0488 HPValve fetched cmd
0x048A HpPool fetched cmd
0x048B HPPumps fetched cmd
0x048D HpPower fetched cmd
0x048F HpTemperatures cmd
0x0491 HPAdditionalHeater fetched cmd
0x0492 HpHeaterConfig fetched cmd
0x0494 UBAEnergySupplied cmd
0x0495 UBAInformation cmd
0x0499 HPDhwSettings fetched cmd
0x049C HPSettings2 fetched cmd
0x049D HPSettings3 fetched cmd
0x04A2 HpInput fetched cmd
0x04A5 HPFan fetched cmd
0x04AE HPEnergy fetched cmd
0x04AF HPMeters fetched cmd
0x056B VentilationMode fetched cmd
0x0583 VentilationMonitor cmd
0x0585 Blowerspeed cmd
0x0587 Bypass cmd
0x05BA HpPoolStatus fetched cmd
0x05D9 Airquality cmd
0x0772 HIUSettings cmd
0x0779 HIUMonitor cmd
0x0935 EM100SetMessage fetched cmd
0x0936 EM100OutMessage cmd
0x0937 EM100TempMessage cmd
0x0938 EM100InputMessage cmd
0x0939 EM100MonitorMessage cmd
0x093A EM100ConfigMessage cmd
0x0998 HPSettings fetched cmd
0x0999 HPFunctionTest fetched cmd
0x099B HPFlowTemp cmd
0x099C HPComp cmd
0x09A0 HPTemperature cmd

All devices and entities~

Download the full CSV file

device name device type product id shortname fullname type [options...] | (min/max) uom writeable discovery entityid v3.4 discovery entityid
CS6800i/WLW176i boiler 8 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
CS6800i/WLW176i boiler 8 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
CS6800i/WLW176i boiler 8 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
CS6800i/WLW176i boiler 8 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
CS6800i/WLW176i boiler 8 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
CS6800i/WLW176i boiler 8 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
CS6800i/WLW176i boiler 8 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
CS6800i/WLW176i boiler 8 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
CS6800i/WLW176i boiler 8 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
CS6800i/WLW176i boiler 8 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
CS6800i/WLW176i boiler 8 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
CS6800i/WLW176i boiler 8 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
CS6800i/WLW176i boiler 8 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
CS6800i/WLW176i boiler 8 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
CS6800i/WLW176i boiler 8 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
CS6800i/WLW176i boiler 8 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
CS6800i/WLW176i boiler 8 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
CS6800i/WLW176i boiler 8 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
CS6800i/WLW176i boiler 8 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
CS6800i/WLW176i boiler 8 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
CS6800i/WLW176i boiler 8 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
CS6800i/WLW176i boiler 8 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
CS6800i/WLW176i boiler 8 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
CS6800i/WLW176i boiler 8 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
CS6800i/WLW176i boiler 8 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
CS6800i/WLW176i boiler 8 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
CS6800i/WLW176i boiler 8 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
CS6800i/WLW176i boiler 8 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
CS6800i/WLW176i boiler 8 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
CS6800i/WLW176i boiler 8 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
CS6800i/WLW176i boiler 8 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
CS6800i/WLW176i boiler 8 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
CS6800i/WLW176i boiler 8 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
CS6800i/WLW176i boiler 8 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
CS6800i/WLW176i boiler 8 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
CS6800i/WLW176i boiler 8 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
CS6800i/WLW176i boiler 8 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
CS6800i/WLW176i boiler 8 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
CS6800i/WLW176i boiler 8 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
CS6800i/WLW176i boiler 8 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal
CS6800i/WLW176i boiler 8 nrgdhw energy uint24 (>=0<=167772) kWh False sensor.boiler_dhw_energy sensor.boiler_dhw_nrgdhw
CS6800i/WLW176i boiler 8 nrgheat energy heating uint24 (>=0<=167772) kWh False sensor.boiler_energy_heating sensor.boiler_nrgheat
CS6800i/WLW176i boiler 8 metertotal meter total uint24 (>=0<=167772) kWh False sensor.boiler_meter_total sensor.boiler_metertotal
CS6800i/WLW176i boiler 8 metercomp meter compressor uint24 (>=0<=167772) kWh False sensor.boiler_meter_compressor sensor.boiler_metercomp
CS6800i/WLW176i boiler 8 metereheat meter e-heater uint24 (>=0<=167772) kWh False sensor.boiler_meter_e-heater sensor.boiler_metereheat
CS6800i/WLW176i boiler 8 meterheat meter heating uint24 (>=0<=167772) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
CS6800i/WLW176i boiler 8 meterdhw meter uint24 (>=0<=167772) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
CS6800i/WLW176i boiler 8 uptimetotal heatpump total uptime time (>=0<=279620) minutes False sensor.boiler_heatpump_total_uptime sensor.boiler_uptimetotal
CS6800i/WLW176i boiler 8 uptimecontrol total operating time heat time (>=0<=279620) minutes False sensor.boiler_total_operating_time_heat sensor.boiler_uptimecontrol
CS6800i/WLW176i boiler 8 uptimecompheating operating time compressor heating time (>=0<=279620) minutes False sensor.boiler_operating_time_compressor_heating sensor.boiler_uptimecompheating
CS6800i/WLW176i boiler 8 uptimecompcooling operating time compressor cooling time (>=0<=279620) minutes False sensor.boiler_operating_time_compressor_cooling sensor.boiler_uptimecompcooling
CS6800i/WLW176i boiler 8 uptimecompdhw operating time compressor time (>=0<=279620) minutes False sensor.boiler_dhw_operating_time_compressor sensor.boiler_dhw_uptimecompdhw
CS6800i/WLW176i boiler 8 uptimecomppool operating time compressor pool time (>=0<=279620) minutes False sensor.boiler_operating_time_compressor_pool sensor.boiler_uptimecomppool
CS6800i/WLW176i boiler 8 totalcompstarts total compressor control starts uint24 (>=0<=16777213) False sensor.boiler_total_compressor_control_starts sensor.boiler_totalcompstarts
CS6800i/WLW176i boiler 8 heatingstarts heating control starts uint24 (>=0<=16777213) False sensor.boiler_heating_control_starts sensor.boiler_heatingstarts
CS6800i/WLW176i boiler 8 coolingstarts cooling control starts uint24 (>=0<=16777213) False sensor.boiler_cooling_control_starts sensor.boiler_coolingstarts
CS6800i/WLW176i boiler 8 starts2 control starts2 uint24 (>=0<=16777213) False sensor.boiler_dhw_control_starts2 sensor.boiler_dhw_starts2
CS6800i/WLW176i boiler 8 poolstarts pool control starts uint24 (>=0<=16777213) False sensor.boiler_pool_control_starts sensor.boiler_poolstarts
CS6800i/WLW176i boiler 8 nrgconstotal total energy consumption uint24 (>=0<=16777213) kWh False sensor.boiler_total_energy_consumption sensor.boiler_nrgconstotal
CS6800i/WLW176i boiler 8 nrgconscomptotal total energy consumption compressor uint24 (>=0<=16777213) kWh False sensor.boiler_total_energy_consumption_compressor sensor.boiler_nrgconscomptotal
CS6800i/WLW176i boiler 8 nrgconscompheating energy consumption compressor heating uint24 (>=0<=16777213) kWh False sensor.boiler_energy_consumption_compressor_heating sensor.boiler_nrgconscompheating
CS6800i/WLW176i boiler 8 nrgconscompdhw energy consumption compressor uint24 (>=0<=16777213) kWh False sensor.boiler_dhw_energy_consumption_compressor sensor.boiler_dhw_nrgconscompdhw
CS6800i/WLW176i boiler 8 nrgconscompcooling energy consumption compressor cooling uint24 (>=0<=16777213) kWh False sensor.boiler_energy_consumption_compressor_cooling sensor.boiler_nrgconscompcooling
CS6800i/WLW176i boiler 8 nrgconscomppool energy consumption compressor pool uint24 (>=0<=16777213) kWh False sensor.boiler_energy_consumption_compressor_pool sensor.boiler_nrgconscomppool
CS6800i/WLW176i boiler 8 auxelecheatnrgconstotal total aux elec. heater energy consumption uint24 (>=0<=16777213) kWh False sensor.boiler_total_aux_elec._heater_energy_consumption sensor.boiler_auxelecheatnrgconstotal
CS6800i/WLW176i boiler 8 auxelecheatnrgconsheating aux elec. heater energy consumption heating uint24 (>=0<=16777213) kWh False sensor.boiler_aux_elec._heater_energy_consumption_heating sensor.boiler_auxelecheatnrgconsheating
CS6800i/WLW176i boiler 8 auxelecheatnrgconsdhw aux elec. heater energy consumption uint24 (>=0<=16777213) kWh False sensor.boiler_dhw_aux_elec._heater_energy_consumption sensor.boiler_dhw_auxelecheatnrgconsdhw
CS6800i/WLW176i boiler 8 auxelecheatnrgconspool aux elec. heater energy consumption pool uint24 (>=0<=16777213) kWh False sensor.boiler_aux_elec._heater_energy_consumption_pool sensor.boiler_auxelecheatnrgconspool
CS6800i/WLW176i boiler 8 nrgsupptotal total energy supplied uint24 (>=0<=16777213) kWh False sensor.boiler_total_energy_supplied sensor.boiler_nrgsupptotal
CS6800i/WLW176i boiler 8 nrgsuppheating total energy supplied heating uint24 (>=0<=16777213) kWh False sensor.boiler_total_energy_supplied_heating sensor.boiler_nrgsuppheating
CS6800i/WLW176i boiler 8 nrgsuppdhw total energy warm supplied uint24 (>=0<=16777213) kWh False sensor.boiler_dhw_total_energy_warm_supplied sensor.boiler_dhw_nrgsuppdhw
CS6800i/WLW176i boiler 8 nrgsuppcooling total energy supplied cooling uint24 (>=0<=16777213) kWh False sensor.boiler_total_energy_supplied_cooling sensor.boiler_nrgsuppcooling
CS6800i/WLW176i boiler 8 nrgsupppool total energy supplied pool uint24 (>=0<=16777213) kWh False sensor.boiler_total_energy_supplied_pool sensor.boiler_nrgsupppool
CS6800i/WLW176i boiler 8 hppower compressor power output uint8 (>=0<=25) kW False sensor.boiler_compressor_power_output sensor.boiler_hppower
CS6800i/WLW176i boiler 8 hpmaxpower compressor max power uint8 (>=0<=100) % True number.boiler_compressor_max_power number.boiler_hpmaxpower
CS6800i/WLW176i boiler 8 hpsetdiffpress set differental pressure uint8 (>=150<=750) mbar True number.boiler_set_differental_pressure number.boiler_hpsetdiffpress
CS6800i/WLW176i boiler 8 hpcompon hp compressor boolean False binary_sensor.boiler_hp_compressor binary_sensor.boiler_hpcompon
CS6800i/WLW176i boiler 8 hpactivity compressor activity enum [none|heating|cooling|hot water|pool|unknown|defrost] False sensor.boiler_compressor_activity sensor.boiler_hpactivity
CS6800i/WLW176i boiler 8 hpbrinepumpspd brine pump speed uint8 (>=0<=100) % False sensor.boiler_brine_pump_speed sensor.boiler_hpbrinepumpspd
CS6800i/WLW176i boiler 8 hpswitchvalve switch valve boolean False binary_sensor.boiler_switch_valve binary_sensor.boiler_hpswitchvalve
CS6800i/WLW176i boiler 8 hpcompspd compressor speed uint8 (>=0<=100) % False sensor.boiler_compressor_speed sensor.boiler_hpcompspd
CS6800i/WLW176i boiler 8 hpcircspd circulation pump speed uint8 (>=0<=100) % False sensor.boiler_circulation_pump_speed sensor.boiler_hpcircspd
CS6800i/WLW176i boiler 8 hpbrinein brine in/evaporator int16 (>=-3199<=3199) C False sensor.boiler_brine_in/evaporator sensor.boiler_hpbrinein
CS6800i/WLW176i boiler 8 hpbrineout brine out/condenser int16 (>=-3199<=3199) C False sensor.boiler_brine_out/condenser sensor.boiler_hpbrineout
CS6800i/WLW176i boiler 8 hptc0 heat carrier return (TC0) int16 (>=-3199<=3199) C False sensor.boiler_heat_carrier_return_(TC0) sensor.boiler_hptc0
CS6800i/WLW176i boiler 8 hptc1 heat carrier forward (TC1) int16 (>=-3199<=3199) C False sensor.boiler_heat_carrier_forward_(TC1) sensor.boiler_hptc1
CS6800i/WLW176i boiler 8 hptc3 condenser temperature (TC3) int16 (>=-3199<=3199) C False sensor.boiler_condenser_temperature_(TC3) sensor.boiler_hptc3
CS6800i/WLW176i boiler 8 hptr1 compressor temperature (TR1) int16 (>=-3199<=3199) C False sensor.boiler_compressor_temperature_(TR1) sensor.boiler_hptr1
CS6800i/WLW176i boiler 8 hptr3 refrigerant temperature liquid side (condenser output) (TR3) int16 (>=-3199<=3199) C False sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3) sensor.boiler_hptr3
CS6800i/WLW176i boiler 8 hptr4 evaporator inlet temperature (TR4) int16 (>=-3199<=3199) C False sensor.boiler_evaporator_inlet_temperature_(TR4) sensor.boiler_hptr4
CS6800i/WLW176i boiler 8 hptr5 compressor inlet temperature (TR5) int16 (>=-3199<=3199) C False sensor.boiler_compressor_inlet_temperature_(TR5) sensor.boiler_hptr5
CS6800i/WLW176i boiler 8 hptr6 compressor outlet temperature (TR6) int16 (>=-3199<=3199) C False sensor.boiler_compressor_outlet_temperature_(TR6) sensor.boiler_hptr6
CS6800i/WLW176i boiler 8 hptr7 refrigerant temperature gas side (condenser input) (TR7) int16 (>=-3199<=3199) C False sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7) sensor.boiler_hptr7
CS6800i/WLW176i boiler 8 hptl2 air inlet temperature (TL2) int16 (>=-3199<=3199) C False sensor.boiler_air_inlet_temperature_(TL2) sensor.boiler_hptl2
CS6800i/WLW176i boiler 8 hppl1 low pressure side temperature (PL1) int16 (>=-3199<=3199) C False sensor.boiler_low_pressure_side_temperature_(PL1) sensor.boiler_hppl1
CS6800i/WLW176i boiler 8 hpph1 high pressure side temperature (PH1) int16 (>=-3199<=3199) C False sensor.boiler_high_pressure_side_temperature_(PH1) sensor.boiler_hpph1
CS6800i/WLW176i boiler 8 hpta4 drain pan temp (TA4) int16 (>=-3199<=3199) C False sensor.boiler_drain_pan_temp_(TA4) sensor.boiler_hpta4
CS6800i/WLW176i boiler 8 hptw1 reservoir temp (TW1) int16 (>=-3199<=3199) C False sensor.boiler_reservoir_temp_(TW1) sensor.boiler_hptw1
CS6800i/WLW176i boiler 8 poolsettemp pool set temperature uint8 (>=0<=127) C True number.boiler_pool_set_temperature number.boiler_poolsettemp
CS6800i/WLW176i boiler 8 hp4way 4-way valve (VR4) enum [cooling & defrost|heating & dhw] False sensor.boiler_4-way_valve_(VR4) sensor.boiler_hp4way
CS6800i/WLW176i boiler 8 hpin1opt input 1 options string True sensor.boiler_input_1_options sensor.boiler_hpin1opt
CS6800i/WLW176i boiler 8 hpin2opt input 2 options string True sensor.boiler_input_2_options sensor.boiler_hpin2opt
CS6800i/WLW176i boiler 8 hpin3opt input 3 options string True sensor.boiler_input_3_options sensor.boiler_hpin3opt
CS6800i/WLW176i boiler 8 hpin4opt input 4 options string True sensor.boiler_input_4_options sensor.boiler_hpin4opt
CS6800i/WLW176i boiler 8 maxheatcomp heat limit compressor enum [0 kW|2 kW|3 kW|4 kW|6 kW|9 kW] True select.boiler_heat_limit_compressor select.boiler_maxheatcomp
CS6800i/WLW176i boiler 8 maxheatheat heat limit heating enum [0 kW|2 kW|3 kW|4 kW|6 kW|9 kW] True select.boiler_heat_limit_heating select.boiler_maxheatheat
CS6800i/WLW176i boiler 8 maxheatdhw heat limit enum [0 kW|2 kW|3 kW|4 kW|6 kW|9 kW] True select.boiler_dhw_heat_limit select.boiler_dhw_maxheatdhw
CS6800i/WLW176i boiler 8 mandefrost manual defrost boolean True switch.boiler_manual_defrost switch.boiler_mandefrost
CS6800i/WLW176i boiler 8 pvcooling cooling only with PV boolean True switch.boiler_cooling_only_with_PV switch.boiler_pvcooling
CS6800i/WLW176i boiler 8 auxheateronly aux heater only boolean True switch.boiler_aux_heater_only switch.boiler_auxheateronly
CS6800i/WLW176i boiler 8 auxheateroff disable aux heater boolean True switch.boiler_disable_aux_heater switch.boiler_auxheateroff
CS6800i/WLW176i boiler 8 auxheaterstatus aux heater status uint8 (>=0<=100) % False sensor.boiler_aux_heater_status sensor.boiler_auxheaterstatus
CS6800i/WLW176i boiler 8 auxheaterdelay aux heater on delay uint16 (>=10<=1000) K*min True number.boiler_aux_heater_on_delay number.boiler_auxheaterdelay
CS6800i/WLW176i boiler 8 auxmaxlimit aux heater max limit uint8 (>=0<=10) K True number.boiler_aux_heater_max_limit number.boiler_auxmaxlimit
CS6800i/WLW176i boiler 8 auxlimitstart aux heater limit start uint8 (>=0<=10) K True number.boiler_aux_heater_limit_start number.boiler_auxlimitstart
CS6800i/WLW176i boiler 8 auxheatrmode aux heater mode enum [eco|comfort] True select.boiler_aux_heater_mode select.boiler_auxheatrmode
CS6800i/WLW176i boiler 8 hphystheat on/off hyst heat uint16 (>=50<=1500) K*min True number.boiler_on/off_hyst_heat number.boiler_hphystheat
CS6800i/WLW176i boiler 8 hphystcool on/off hyst cool uint16 (>=50<=1500) K*min True number.boiler_on/off_hyst_cool number.boiler_hphystcool
CS6800i/WLW176i boiler 8 hphystpool on/off hyst pool uint16 (>=50<=1500) K*min True number.boiler_on/off_hyst_pool number.boiler_hphystpool
CS6800i/WLW176i boiler 8 silentmode silent mode enum [off|auto|on] True select.boiler_silent_mode select.boiler_silentmode
CS6800i/WLW176i boiler 8 silentfrom silent mode from uint8 (>=0<=3810) minutes True number.boiler_silent_mode_from number.boiler_silentfrom
CS6800i/WLW176i boiler 8 silentto silent mode to uint8 (>=0<=3810) minutes True number.boiler_silent_mode_to number.boiler_silentto
CS6800i/WLW176i boiler 8 mintempsilent min outside temp for silent mode int8 (>=-126<=126) C True number.boiler_min_outside_temp_for_silent_mode number.boiler_mintempsilent
CS6800i/WLW176i boiler 8 tempparmode outside temp parallel mode int8 (>=-126<=126) C True number.boiler_outside_temp_parallel_mode number.boiler_tempparmode
CS6800i/WLW176i boiler 8 auxheatmix aux heater mixing valve int8 (>=-100<=100) % False sensor.boiler_aux_heater_mixing_valve sensor.boiler_auxheatmix
CS6800i/WLW176i boiler 8 tempdiffheat temp diff TC3/TC0 heat uint8 (>=2<=10) K True number.boiler_temp_diff_TC3/TC0_heat number.boiler_tempdiffheat
CS6800i/WLW176i boiler 8 tempdiffcool temp diff TC3/TC0 cool uint8 (>=2<=10) K True number.boiler_temp_diff_TC3/TC0_cool number.boiler_tempdiffcool
CS6800i/WLW176i boiler 8 vpcooling valve/pump cooling boolean True switch.boiler_valve/pump_cooling switch.boiler_vpcooling
CS6800i/WLW176i boiler 8 heatcable heating cable boolean True switch.boiler_heating_cable switch.boiler_heatcable
CS6800i/WLW176i boiler 8 vc0valve VC0 valve boolean True switch.boiler_VC0_valve switch.boiler_vc0valve
CS6800i/WLW176i boiler 8 primepump primary heatpump boolean True switch.boiler_primary_heatpump switch.boiler_primepump
CS6800i/WLW176i boiler 8 primepumpmod primary heatpump modulation uint8 (>=0<=100) % True number.boiler_primary_heatpump_modulation number.boiler_primepumpmod
CS6800i/WLW176i boiler 8 hp3way 3-way valve boolean True switch.boiler_3-way_valve switch.boiler_hp3way
CS6800i/WLW176i boiler 8 elheatstep1 el. heater step 1 boolean True switch.boiler_el._heater_step_1 switch.boiler_elheatstep1
CS6800i/WLW176i boiler 8 elheatstep2 el. heater step 2 boolean True switch.boiler_el._heater_step_2 switch.boiler_elheatstep2
CS6800i/WLW176i boiler 8 elheatstep3 el. heater step 3 boolean True switch.boiler_el._heater_step_3 switch.boiler_elheatstep3
CS6800i/WLW176i boiler 8 hpea0 condensate reservoir heating (EA0) boolean False binary_sensor.boiler_condensate_reservoir_heating_(EA0) binary_sensor.boiler_hpea0
CS6800i/WLW176i boiler 8 hppumpmode primary heatpump mode enum [auto|continuous] True select.boiler_primary_heatpump_mode select.boiler_hppumpmode
CS6800i/WLW176i boiler 8 fan fan uint8 (>=20<=100) % True number.boiler_fan number.boiler_fan
CS6800i/WLW176i boiler 8 shutdown shutdown boolean True switch.boiler_shutdown switch.boiler_shutdown
CS6800i/WLW176i boiler 8 alternatingop alternating operation boolean True switch.boiler_dhw_alternating_operation switch.boiler_dhw_alternatingop
CS6800i/WLW176i boiler 8 altopprioheat prioritise heating during dhw uint8 (>=20<=120) minutes True number.boiler_dhw_prioritise_heating_during_dhw number.boiler_dhw_altopprioheat
CS6800i/WLW176i boiler 8 altoppriodhw prioritise dhw during heating uint8 (>=30<=120) minutes True number.boiler_dhw_prioritise_dhw_during_heating number.boiler_dhw_altoppriodhw
CS6800i/WLW176i boiler 8 comfoff comfort switch off uint8 (>=15<=65) C True number.boiler_dhw_comfort_switch_off number.boiler_dhw_comfoff
CS6800i/WLW176i boiler 8 ecooff eco switch off uint8 (>=15<=65) C True number.boiler_dhw_eco_switch_off number.boiler_dhw_ecooff
CS6800i/WLW176i boiler 8 ecoplusoff eco+ switch off uint8 (>=48<=63) C True number.boiler_dhw_eco+_switch_off number.boiler_dhw_ecoplusoff
CS6800i/WLW176i boiler 8 comfdiff comfort diff uint8 (>=6<=12) K True number.boiler_dhw_comfort_diff number.boiler_dhw_comfdiff
CS6800i/WLW176i boiler 8 ecodiff eco diff uint8 (>=6<=12) K True number.boiler_dhw_eco_diff number.boiler_dhw_ecodiff
CS6800i/WLW176i boiler 8 ecoplusdiff eco+ diff uint8 (>=6<=12) K True number.boiler_dhw_eco+_diff number.boiler_dhw_ecoplusdiff
CS6800i/WLW176i boiler 8 comfstop comfort stop temp uint8 (>=0<=254) C True number.boiler_dhw_comfort_stop_temp number.boiler_dhw_comfstop
CS6800i/WLW176i boiler 8 ecostop eco stop temp uint8 (>=0<=254) C True number.boiler_dhw_eco_stop_temp number.boiler_dhw_ecostop
CS6800i/WLW176i boiler 8 ecoplusstop eco+ stop temp uint8 (>=0<=254) C True number.boiler_dhw_eco+_stop_temp number.boiler_dhw_ecoplusstop
CS6800i/WLW176i boiler 8 hpcircpumpdhw circulation pump available during dhw boolean True switch.boiler_dhw_circulation_pump_available_during_dhw switch.boiler_dhw_hpcircpumpdhw
CS6800i/WLW176i boiler 8 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
CS6800i/WLW176i boiler 8 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
CS6800i/WLW176i boiler 8 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
CS6800i/WLW176i boiler 8 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
CS6800i/WLW176i boiler 8 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
CS6800i/WLW176i boiler 8 seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff
CS6800i/WLW176i boiler 8 seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle
CS6800i/WLW176i boiler 8 solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp
CS6800i/WLW176i boiler 8 type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type
CS6800i/WLW176i boiler 8 comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort
CS6800i/WLW176i boiler 8 comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1
CS6800i/WLW176i boiler 8 flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset
CS6800i/WLW176i boiler 8 chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization
CS6800i/WLW176i boiler 8 maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower
CS6800i/WLW176i boiler 8 maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp
CS6800i/WLW176i boiler 8 circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump
CS6800i/WLW176i boiler 8 chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype
CS6800i/WLW176i boiler 8 hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston
CS6800i/WLW176i boiler 8 hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff
CS6800i/WLW176i boiler 8 disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp
CS6800i/WLW176i boiler 8 circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode
CS6800i/WLW176i boiler 8 circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ
CS6800i/WLW176i boiler 8 curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp
CS6800i/WLW176i boiler 8 curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2
CS6800i/WLW176i boiler 8 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
CS6800i/WLW176i boiler 8 storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1
CS6800i/WLW176i boiler 8 storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2
CS6800i/WLW176i boiler 8 activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated
CS6800i/WLW176i boiler 8 onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime
CS6800i/WLW176i boiler 8 disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting
CS6800i/WLW176i boiler 8 charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging
CS6800i/WLW176i boiler 8 recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging
CS6800i/WLW176i boiler 8 tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok
CS6800i/WLW176i boiler 8 active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active
CS6800i/WLW176i boiler 8 3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve
CS6800i/WLW176i boiler 8 setpumppower set pump power uint8 (>=0<=100) % False sensor.boiler_dhw_set_pump_power sensor.boiler_dhw_setpumppower
CS6800i/WLW176i boiler 8 mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp
CS6800i/WLW176i boiler 8 cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp
CS6800i/WLW176i boiler 8 starts starts uint24 (>=0<=16777213) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts
CS6800i/WLW176i boiler 8 workm active time time (>=0<=16777213) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm
C1200W boiler 12 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
C1200W boiler 12 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
C1200W boiler 12 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
C1200W boiler 12 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
C1200W boiler 12 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
C1200W boiler 12 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
C1200W boiler 12 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
C1200W boiler 12 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
C1200W boiler 12 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
C1200W boiler 12 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
C1200W boiler 12 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
C1200W boiler 12 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
C1200W boiler 12 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
C1200W boiler 12 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp
C1200W boiler 12 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas
C1200W boiler 12 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2
C1200W boiler 12 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr
C1200W boiler 12 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork
C1200W boiler 12 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork
C1200W boiler 12 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat
C1200W boiler 12 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower
C1200W boiler 12 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower
C1200W boiler 12 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod
C1200W boiler 12 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow
C1200W boiler 12 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock
C1200W boiler 12 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston
C1200W boiler 12 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff
C1200W boiler 12 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston
C1200W boiler 12 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff
C1200W boiler 12 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon
C1200W boiler 12 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase
C1200W boiler 12 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend
C1200W boiler 12 summertemp summer temperature uint8 (>=0<=30) C True number.boiler_summer_temperature number.boiler_summertemp
C1200W boiler 12 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode
C1200W boiler 12 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp
C1200W boiler 12 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
C1200W boiler 12 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
C1200W boiler 12 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
C1200W boiler 12 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
C1200W boiler 12 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
C1200W boiler 12 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
C1200W boiler 12 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
C1200W boiler 12 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
C1200W boiler 12 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
C1200W boiler 12 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
C1200W boiler 12 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
C1200W boiler 12 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
C1200W boiler 12 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
C1200W boiler 12 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
C1200W boiler 12 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
C1200W boiler 12 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
C1200W boiler 12 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
C1200W boiler 12 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
C1200W boiler 12 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
C1200W boiler 12 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
C1200W boiler 12 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
C1200W boiler 12 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
C1200W boiler 12 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
C1200W boiler 12 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
C1200W boiler 12 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
C1200W boiler 12 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
C1200W boiler 12 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
C1200W boiler 12 meterdhw meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
C1200W boiler 12 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat
C1200W boiler 12 gasmeterdhw gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeterdhw
C1200W boiler 12 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2
C1200W boiler 12 nrgdhw2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrgdhw2
C1200W boiler 12 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
C1200W boiler 12 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
C1200W boiler 12 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
C1200W boiler 12 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
C1200W boiler 12 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
C1200W boiler 12 seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff
C1200W boiler 12 seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle
C1200W boiler 12 solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp
C1200W boiler 12 type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type
C1200W boiler 12 comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort
C1200W boiler 12 comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1
C1200W boiler 12 flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset
C1200W boiler 12 chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization
C1200W boiler 12 maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower
C1200W boiler 12 maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp
C1200W boiler 12 circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump
C1200W boiler 12 chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype
C1200W boiler 12 hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston
C1200W boiler 12 hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff
C1200W boiler 12 disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp
C1200W boiler 12 circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode
C1200W boiler 12 circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ
C1200W boiler 12 curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp
C1200W boiler 12 curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2
C1200W boiler 12 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
C1200W boiler 12 storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1
C1200W boiler 12 storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2
C1200W boiler 12 activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated
C1200W boiler 12 onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime
C1200W boiler 12 disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting
C1200W boiler 12 charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging
C1200W boiler 12 recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging
C1200W boiler 12 tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok
C1200W boiler 12 active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active
C1200W boiler 12 3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve
C1200W boiler 12 setpumppower set pump power uint8 (>=0<=100) % False sensor.boiler_dhw_set_pump_power sensor.boiler_dhw_setpumppower
C1200W boiler 12 mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp
C1200W boiler 12 cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp
C1200W boiler 12 starts starts uint24 (>=0<=16777213) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts
C1200W boiler 12 workm active time time (>=0<=16777213) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm
C1200W boiler 12 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower
C1200W boiler 12 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal
C1200W boiler 12 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat
C1200W boiler 12 nrgdhw energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrgdhw
BK13/BK15/Smartline/GB1x2 boiler 64 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
BK13/BK15/Smartline/GB1x2 boiler 64 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
BK13/BK15/Smartline/GB1x2 boiler 64 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
BK13/BK15/Smartline/GB1x2 boiler 64 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
BK13/BK15/Smartline/GB1x2 boiler 64 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
BK13/BK15/Smartline/GB1x2 boiler 64 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
BK13/BK15/Smartline/GB1x2 boiler 64 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
BK13/BK15/Smartline/GB1x2 boiler 64 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
BK13/BK15/Smartline/GB1x2 boiler 64 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
BK13/BK15/Smartline/GB1x2 boiler 64 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
BK13/BK15/Smartline/GB1x2 boiler 64 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
BK13/BK15/Smartline/GB1x2 boiler 64 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
BK13/BK15/Smartline/GB1x2 boiler 64 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
BK13/BK15/Smartline/GB1x2 boiler 64 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp
BK13/BK15/Smartline/GB1x2 boiler 64 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas
BK13/BK15/Smartline/GB1x2 boiler 64 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2
BK13/BK15/Smartline/GB1x2 boiler 64 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr
BK13/BK15/Smartline/GB1x2 boiler 64 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork
BK13/BK15/Smartline/GB1x2 boiler 64 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork
BK13/BK15/Smartline/GB1x2 boiler 64 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat
BK13/BK15/Smartline/GB1x2 boiler 64 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower
BK13/BK15/Smartline/GB1x2 boiler 64 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower
BK13/BK15/Smartline/GB1x2 boiler 64 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod
BK13/BK15/Smartline/GB1x2 boiler 64 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow
BK13/BK15/Smartline/GB1x2 boiler 64 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock
BK13/BK15/Smartline/GB1x2 boiler 64 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston
BK13/BK15/Smartline/GB1x2 boiler 64 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff
BK13/BK15/Smartline/GB1x2 boiler 64 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston
BK13/BK15/Smartline/GB1x2 boiler 64 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff
BK13/BK15/Smartline/GB1x2 boiler 64 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon
BK13/BK15/Smartline/GB1x2 boiler 64 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase
BK13/BK15/Smartline/GB1x2 boiler 64 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend
BK13/BK15/Smartline/GB1x2 boiler 64 summertemp summer temperature uint8 (>=0<=30) C True number.boiler_summer_temperature number.boiler_summertemp
BK13/BK15/Smartline/GB1x2 boiler 64 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode
BK13/BK15/Smartline/GB1x2 boiler 64 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp
BK13/BK15/Smartline/GB1x2 boiler 64 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
BK13/BK15/Smartline/GB1x2 boiler 64 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
BK13/BK15/Smartline/GB1x2 boiler 64 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
BK13/BK15/Smartline/GB1x2 boiler 64 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
BK13/BK15/Smartline/GB1x2 boiler 64 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
BK13/BK15/Smartline/GB1x2 boiler 64 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
BK13/BK15/Smartline/GB1x2 boiler 64 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
BK13/BK15/Smartline/GB1x2 boiler 64 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
BK13/BK15/Smartline/GB1x2 boiler 64 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
BK13/BK15/Smartline/GB1x2 boiler 64 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
BK13/BK15/Smartline/GB1x2 boiler 64 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
BK13/BK15/Smartline/GB1x2 boiler 64 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
BK13/BK15/Smartline/GB1x2 boiler 64 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
BK13/BK15/Smartline/GB1x2 boiler 64 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
BK13/BK15/Smartline/GB1x2 boiler 64 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
BK13/BK15/Smartline/GB1x2 boiler 64 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
BK13/BK15/Smartline/GB1x2 boiler 64 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
BK13/BK15/Smartline/GB1x2 boiler 64 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
BK13/BK15/Smartline/GB1x2 boiler 64 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
BK13/BK15/Smartline/GB1x2 boiler 64 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
BK13/BK15/Smartline/GB1x2 boiler 64 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
BK13/BK15/Smartline/GB1x2 boiler 64 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
BK13/BK15/Smartline/GB1x2 boiler 64 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
BK13/BK15/Smartline/GB1x2 boiler 64 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
BK13/BK15/Smartline/GB1x2 boiler 64 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
BK13/BK15/Smartline/GB1x2 boiler 64 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
BK13/BK15/Smartline/GB1x2 boiler 64 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
BK13/BK15/Smartline/GB1x2 boiler 64 meterdhw meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
BK13/BK15/Smartline/GB1x2 boiler 64 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat
BK13/BK15/Smartline/GB1x2 boiler 64 gasmeterdhw gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeterdhw
BK13/BK15/Smartline/GB1x2 boiler 64 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2
BK13/BK15/Smartline/GB1x2 boiler 64 nrgdhw2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrgdhw2
BK13/BK15/Smartline/GB1x2 boiler 64 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
BK13/BK15/Smartline/GB1x2 boiler 64 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
BK13/BK15/Smartline/GB1x2 boiler 64 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
BK13/BK15/Smartline/GB1x2 boiler 64 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
BK13/BK15/Smartline/GB1x2 boiler 64 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
BK13/BK15/Smartline/GB1x2 boiler 64 seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff
BK13/BK15/Smartline/GB1x2 boiler 64 seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle
BK13/BK15/Smartline/GB1x2 boiler 64 solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp
BK13/BK15/Smartline/GB1x2 boiler 64 type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type
BK13/BK15/Smartline/GB1x2 boiler 64 comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort
BK13/BK15/Smartline/GB1x2 boiler 64 comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1
BK13/BK15/Smartline/GB1x2 boiler 64 flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset
BK13/BK15/Smartline/GB1x2 boiler 64 chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization
BK13/BK15/Smartline/GB1x2 boiler 64 maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower
BK13/BK15/Smartline/GB1x2 boiler 64 maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp
BK13/BK15/Smartline/GB1x2 boiler 64 circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump
BK13/BK15/Smartline/GB1x2 boiler 64 chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype
BK13/BK15/Smartline/GB1x2 boiler 64 hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston
BK13/BK15/Smartline/GB1x2 boiler 64 hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff
BK13/BK15/Smartline/GB1x2 boiler 64 disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp
BK13/BK15/Smartline/GB1x2 boiler 64 circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode
BK13/BK15/Smartline/GB1x2 boiler 64 circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ
BK13/BK15/Smartline/GB1x2 boiler 64 curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp
BK13/BK15/Smartline/GB1x2 boiler 64 curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2
BK13/BK15/Smartline/GB1x2 boiler 64 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
BK13/BK15/Smartline/GB1x2 boiler 64 storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1
BK13/BK15/Smartline/GB1x2 boiler 64 storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2
BK13/BK15/Smartline/GB1x2 boiler 64 activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated
BK13/BK15/Smartline/GB1x2 boiler 64 onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime
BK13/BK15/Smartline/GB1x2 boiler 64 disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting
BK13/BK15/Smartline/GB1x2 boiler 64 charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging
BK13/BK15/Smartline/GB1x2 boiler 64 recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging
BK13/BK15/Smartline/GB1x2 boiler 64 tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok
BK13/BK15/Smartline/GB1x2 boiler 64 active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active
BK13/BK15/Smartline/GB1x2 boiler 64 3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve
BK13/BK15/Smartline/GB1x2 boiler 64 setpumppower set pump power uint8 (>=0<=100) % False sensor.boiler_dhw_set_pump_power sensor.boiler_dhw_setpumppower
BK13/BK15/Smartline/GB1x2 boiler 64 mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp
BK13/BK15/Smartline/GB1x2 boiler 64 cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp
BK13/BK15/Smartline/GB1x2 boiler 64 starts starts uint24 (>=0<=16777213) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts
BK13/BK15/Smartline/GB1x2 boiler 64 workm active time time (>=0<=16777213) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm
BK13/BK15/Smartline/GB1x2 boiler 64 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower
BK13/BK15/Smartline/GB1x2 boiler 64 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal
BK13/BK15/Smartline/GB1x2 boiler 64 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat
BK13/BK15/Smartline/GB1x2 boiler 64 nrgdhw energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrgdhw
GB125/GB135/MC10 boiler 72 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
GB125/GB135/MC10 boiler 72 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
GB125/GB135/MC10 boiler 72 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
GB125/GB135/MC10 boiler 72 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
GB125/GB135/MC10 boiler 72 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
GB125/GB135/MC10 boiler 72 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
GB125/GB135/MC10 boiler 72 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
GB125/GB135/MC10 boiler 72 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
GB125/GB135/MC10 boiler 72 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
GB125/GB135/MC10 boiler 72 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
GB125/GB135/MC10 boiler 72 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
GB125/GB135/MC10 boiler 72 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
GB125/GB135/MC10 boiler 72 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
GB125/GB135/MC10 boiler 72 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp
GB125/GB135/MC10 boiler 72 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas
GB125/GB135/MC10 boiler 72 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2
GB125/GB135/MC10 boiler 72 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr
GB125/GB135/MC10 boiler 72 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork
GB125/GB135/MC10 boiler 72 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork
GB125/GB135/MC10 boiler 72 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat
GB125/GB135/MC10 boiler 72 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower
GB125/GB135/MC10 boiler 72 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower
GB125/GB135/MC10 boiler 72 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod
GB125/GB135/MC10 boiler 72 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow
GB125/GB135/MC10 boiler 72 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock
GB125/GB135/MC10 boiler 72 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston
GB125/GB135/MC10 boiler 72 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff
GB125/GB135/MC10 boiler 72 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston
GB125/GB135/MC10 boiler 72 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff
GB125/GB135/MC10 boiler 72 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon
GB125/GB135/MC10 boiler 72 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase
GB125/GB135/MC10 boiler 72 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend
GB125/GB135/MC10 boiler 72 summertemp summer temperature uint8 (>=0<=30) C True number.boiler_summer_temperature number.boiler_summertemp
GB125/GB135/MC10 boiler 72 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode
GB125/GB135/MC10 boiler 72 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp
GB125/GB135/MC10 boiler 72 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
GB125/GB135/MC10 boiler 72 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
GB125/GB135/MC10 boiler 72 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
GB125/GB135/MC10 boiler 72 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
GB125/GB135/MC10 boiler 72 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
GB125/GB135/MC10 boiler 72 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
GB125/GB135/MC10 boiler 72 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
GB125/GB135/MC10 boiler 72 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
GB125/GB135/MC10 boiler 72 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
GB125/GB135/MC10 boiler 72 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
GB125/GB135/MC10 boiler 72 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
GB125/GB135/MC10 boiler 72 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
GB125/GB135/MC10 boiler 72 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
GB125/GB135/MC10 boiler 72 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
GB125/GB135/MC10 boiler 72 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
GB125/GB135/MC10 boiler 72 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
GB125/GB135/MC10 boiler 72 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
GB125/GB135/MC10 boiler 72 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
GB125/GB135/MC10 boiler 72 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
GB125/GB135/MC10 boiler 72 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
GB125/GB135/MC10 boiler 72 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
GB125/GB135/MC10 boiler 72 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
GB125/GB135/MC10 boiler 72 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
GB125/GB135/MC10 boiler 72 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
GB125/GB135/MC10 boiler 72 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
GB125/GB135/MC10 boiler 72 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
GB125/GB135/MC10 boiler 72 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
GB125/GB135/MC10 boiler 72 meterdhw meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
GB125/GB135/MC10 boiler 72 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat
GB125/GB135/MC10 boiler 72 gasmeterdhw gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeterdhw
GB125/GB135/MC10 boiler 72 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2
GB125/GB135/MC10 boiler 72 nrgdhw2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrgdhw2
GB125/GB135/MC10 boiler 72 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
GB125/GB135/MC10 boiler 72 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
GB125/GB135/MC10 boiler 72 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
GB125/GB135/MC10 boiler 72 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
GB125/GB135/MC10 boiler 72 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
GB125/GB135/MC10 boiler 72 seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff
GB125/GB135/MC10 boiler 72 seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle
GB125/GB135/MC10 boiler 72 solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp
GB125/GB135/MC10 boiler 72 type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type
GB125/GB135/MC10 boiler 72 comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort
GB125/GB135/MC10 boiler 72 comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1
GB125/GB135/MC10 boiler 72 flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset
GB125/GB135/MC10 boiler 72 chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization
GB125/GB135/MC10 boiler 72 maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower
GB125/GB135/MC10 boiler 72 maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp
GB125/GB135/MC10 boiler 72 circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump
GB125/GB135/MC10 boiler 72 chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype
GB125/GB135/MC10 boiler 72 hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston
GB125/GB135/MC10 boiler 72 hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff
GB125/GB135/MC10 boiler 72 disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp
GB125/GB135/MC10 boiler 72 circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode
GB125/GB135/MC10 boiler 72 circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ
GB125/GB135/MC10 boiler 72 curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp
GB125/GB135/MC10 boiler 72 curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2
GB125/GB135/MC10 boiler 72 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
GB125/GB135/MC10 boiler 72 storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1
GB125/GB135/MC10 boiler 72 storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2
GB125/GB135/MC10 boiler 72 activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated
GB125/GB135/MC10 boiler 72 onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime
GB125/GB135/MC10 boiler 72 disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting
GB125/GB135/MC10 boiler 72 charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging
GB125/GB135/MC10 boiler 72 recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging
GB125/GB135/MC10 boiler 72 tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok
GB125/GB135/MC10 boiler 72 active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active
GB125/GB135/MC10 boiler 72 3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve
GB125/GB135/MC10 boiler 72 setpumppower set pump power uint8 (>=0<=100) % False sensor.boiler_dhw_set_pump_power sensor.boiler_dhw_setpumppower
GB125/GB135/MC10 boiler 72 mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp
GB125/GB135/MC10 boiler 72 cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp
GB125/GB135/MC10 boiler 72 starts starts uint24 (>=0<=16777213) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts
GB125/GB135/MC10 boiler 72 workm active time time (>=0<=16777213) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm
GB125/GB135/MC10 boiler 72 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower
GB125/GB135/MC10 boiler 72 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal
GB125/GB135/MC10 boiler 72 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat
GB125/GB135/MC10 boiler 72 nrgdhw energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrgdhw
Cascade CM10 boiler 81 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
Cascade CM10 boiler 81 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
Cascade CM10 boiler 81 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
Cascade CM10 boiler 81 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
Cascade CM10 boiler 81 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
Cascade CM10 boiler 81 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
Cascade CM10 boiler 81 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
Cascade CM10 boiler 81 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
Cascade CM10 boiler 81 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
Cascade CM10 boiler 81 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
Cascade CM10 boiler 81 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
Cascade CM10 boiler 81 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
Cascade CM10 boiler 81 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
Cascade CM10 boiler 81 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp
Cascade CM10 boiler 81 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas
Cascade CM10 boiler 81 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2
Cascade CM10 boiler 81 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr
Cascade CM10 boiler 81 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork
Cascade CM10 boiler 81 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork
Cascade CM10 boiler 81 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat
Cascade CM10 boiler 81 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower
Cascade CM10 boiler 81 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower
Cascade CM10 boiler 81 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod
Cascade CM10 boiler 81 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow
Cascade CM10 boiler 81 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock
Cascade CM10 boiler 81 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston
Cascade CM10 boiler 81 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff
Cascade CM10 boiler 81 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston
Cascade CM10 boiler 81 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff
Cascade CM10 boiler 81 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon
Cascade CM10 boiler 81 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase
Cascade CM10 boiler 81 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend
Cascade CM10 boiler 81 summertemp summer temperature uint8 (>=0<=30) C True number.boiler_summer_temperature number.boiler_summertemp
Cascade CM10 boiler 81 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode
Cascade CM10 boiler 81 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp
Cascade CM10 boiler 81 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
Cascade CM10 boiler 81 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
Cascade CM10 boiler 81 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
Cascade CM10 boiler 81 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
Cascade CM10 boiler 81 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
Cascade CM10 boiler 81 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
Cascade CM10 boiler 81 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
Cascade CM10 boiler 81 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
Cascade CM10 boiler 81 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
Cascade CM10 boiler 81 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
Cascade CM10 boiler 81 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
Cascade CM10 boiler 81 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
Cascade CM10 boiler 81 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
Cascade CM10 boiler 81 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
Cascade CM10 boiler 81 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
Cascade CM10 boiler 81 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
Cascade CM10 boiler 81 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
Cascade CM10 boiler 81 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
Cascade CM10 boiler 81 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
Cascade CM10 boiler 81 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
Cascade CM10 boiler 81 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
Cascade CM10 boiler 81 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
Cascade CM10 boiler 81 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
Cascade CM10 boiler 81 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
Cascade CM10 boiler 81 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
Cascade CM10 boiler 81 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
Cascade CM10 boiler 81 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
Cascade CM10 boiler 81 meterdhw meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
Cascade CM10 boiler 81 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat
Cascade CM10 boiler 81 gasmeterdhw gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeterdhw
Cascade CM10 boiler 81 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2
Cascade CM10 boiler 81 nrgdhw2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrgdhw2
Cascade CM10 boiler 81 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
Cascade CM10 boiler 81 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
Cascade CM10 boiler 81 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
Cascade CM10 boiler 81 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
Cascade CM10 boiler 81 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
Cascade CM10 boiler 81 seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff
Cascade CM10 boiler 81 seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle
Cascade CM10 boiler 81 solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp
Cascade CM10 boiler 81 type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type
Cascade CM10 boiler 81 comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort
Cascade CM10 boiler 81 comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1
Cascade CM10 boiler 81 flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset
Cascade CM10 boiler 81 chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization
Cascade CM10 boiler 81 maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower
Cascade CM10 boiler 81 maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp
Cascade CM10 boiler 81 circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump
Cascade CM10 boiler 81 chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype
Cascade CM10 boiler 81 hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston
Cascade CM10 boiler 81 hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff
Cascade CM10 boiler 81 disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp
Cascade CM10 boiler 81 circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode
Cascade CM10 boiler 81 circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ
Cascade CM10 boiler 81 curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp
Cascade CM10 boiler 81 curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2
Cascade CM10 boiler 81 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
Cascade CM10 boiler 81 storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1
Cascade CM10 boiler 81 storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2
Cascade CM10 boiler 81 activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated
Cascade CM10 boiler 81 onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime
Cascade CM10 boiler 81 disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting
Cascade CM10 boiler 81 charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging
Cascade CM10 boiler 81 recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging
Cascade CM10 boiler 81 tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok
Cascade CM10 boiler 81 active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active
Cascade CM10 boiler 81 3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve
Cascade CM10 boiler 81 setpumppower set pump power uint8 (>=0<=100) % False sensor.boiler_dhw_set_pump_power sensor.boiler_dhw_setpumppower
Cascade CM10 boiler 81 mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp
Cascade CM10 boiler 81 cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp
Cascade CM10 boiler 81 starts starts uint24 (>=0<=16777213) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts
Cascade CM10 boiler 81 workm active time time (>=0<=16777213) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm
Cascade CM10 boiler 81 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower
Cascade CM10 boiler 81 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal
Cascade CM10 boiler 81 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat
Cascade CM10 boiler 81 nrgdhw energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrgdhw
Logamax Plus GB022 boiler 84 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
Logamax Plus GB022 boiler 84 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
Logamax Plus GB022 boiler 84 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
Logamax Plus GB022 boiler 84 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
Logamax Plus GB022 boiler 84 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
Logamax Plus GB022 boiler 84 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
Logamax Plus GB022 boiler 84 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
Logamax Plus GB022 boiler 84 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
Logamax Plus GB022 boiler 84 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
Logamax Plus GB022 boiler 84 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
Logamax Plus GB022 boiler 84 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
Logamax Plus GB022 boiler 84 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
Logamax Plus GB022 boiler 84 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
Logamax Plus GB022 boiler 84 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp
Logamax Plus GB022 boiler 84 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas
Logamax Plus GB022 boiler 84 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2
Logamax Plus GB022 boiler 84 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr
Logamax Plus GB022 boiler 84 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork
Logamax Plus GB022 boiler 84 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork
Logamax Plus GB022 boiler 84 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat
Logamax Plus GB022 boiler 84 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower
Logamax Plus GB022 boiler 84 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower
Logamax Plus GB022 boiler 84 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod
Logamax Plus GB022 boiler 84 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow
Logamax Plus GB022 boiler 84 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock
Logamax Plus GB022 boiler 84 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston
Logamax Plus GB022 boiler 84 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff
Logamax Plus GB022 boiler 84 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston
Logamax Plus GB022 boiler 84 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff
Logamax Plus GB022 boiler 84 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon
Logamax Plus GB022 boiler 84 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase
Logamax Plus GB022 boiler 84 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend
Logamax Plus GB022 boiler 84 summertemp summer temperature uint8 (>=0<=30) C True number.boiler_summer_temperature number.boiler_summertemp
Logamax Plus GB022 boiler 84 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode
Logamax Plus GB022 boiler 84 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp
Logamax Plus GB022 boiler 84 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
Logamax Plus GB022 boiler 84 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
Logamax Plus GB022 boiler 84 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
Logamax Plus GB022 boiler 84 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
Logamax Plus GB022 boiler 84 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
Logamax Plus GB022 boiler 84 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
Logamax Plus GB022 boiler 84 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
Logamax Plus GB022 boiler 84 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
Logamax Plus GB022 boiler 84 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
Logamax Plus GB022 boiler 84 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
Logamax Plus GB022 boiler 84 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
Logamax Plus GB022 boiler 84 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
Logamax Plus GB022 boiler 84 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
Logamax Plus GB022 boiler 84 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
Logamax Plus GB022 boiler 84 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
Logamax Plus GB022 boiler 84 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
Logamax Plus GB022 boiler 84 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
Logamax Plus GB022 boiler 84 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
Logamax Plus GB022 boiler 84 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
Logamax Plus GB022 boiler 84 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
Logamax Plus GB022 boiler 84 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
Logamax Plus GB022 boiler 84 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
Logamax Plus GB022 boiler 84 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
Logamax Plus GB022 boiler 84 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
Logamax Plus GB022 boiler 84 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
Logamax Plus GB022 boiler 84 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
Logamax Plus GB022 boiler 84 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
Logamax Plus GB022 boiler 84 meterdhw meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
Logamax Plus GB022 boiler 84 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat
Logamax Plus GB022 boiler 84 gasmeterdhw gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeterdhw
Logamax Plus GB022 boiler 84 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2
Logamax Plus GB022 boiler 84 nrgdhw2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrgdhw2
Logamax Plus GB022 boiler 84 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
Logamax Plus GB022 boiler 84 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
Logamax Plus GB022 boiler 84 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
Logamax Plus GB022 boiler 84 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
Logamax Plus GB022 boiler 84 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
Logamax Plus GB022 boiler 84 seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff
Logamax Plus GB022 boiler 84 seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle
Logamax Plus GB022 boiler 84 solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp
Logamax Plus GB022 boiler 84 type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type
Logamax Plus GB022 boiler 84 comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort
Logamax Plus GB022 boiler 84 comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1
Logamax Plus GB022 boiler 84 flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset
Logamax Plus GB022 boiler 84 chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization
Logamax Plus GB022 boiler 84 maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower
Logamax Plus GB022 boiler 84 maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp
Logamax Plus GB022 boiler 84 circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump
Logamax Plus GB022 boiler 84 chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype
Logamax Plus GB022 boiler 84 hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston
Logamax Plus GB022 boiler 84 hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff
Logamax Plus GB022 boiler 84 disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp
Logamax Plus GB022 boiler 84 circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode
Logamax Plus GB022 boiler 84 circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ
Logamax Plus GB022 boiler 84 curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp
Logamax Plus GB022 boiler 84 curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2
Logamax Plus GB022 boiler 84 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
Logamax Plus GB022 boiler 84 storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1
Logamax Plus GB022 boiler 84 storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2
Logamax Plus GB022 boiler 84 activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated
Logamax Plus GB022 boiler 84 onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime
Logamax Plus GB022 boiler 84 disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting
Logamax Plus GB022 boiler 84 charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging
Logamax Plus GB022 boiler 84 recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging
Logamax Plus GB022 boiler 84 tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok
Logamax Plus GB022 boiler 84 active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active
Logamax Plus GB022 boiler 84 3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve
Logamax Plus GB022 boiler 84 setpumppower set pump power uint8 (>=0<=100) % False sensor.boiler_dhw_set_pump_power sensor.boiler_dhw_setpumppower
Logamax Plus GB022 boiler 84 mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp
Logamax Plus GB022 boiler 84 cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp
Logamax Plus GB022 boiler 84 starts starts uint24 (>=0<=16777213) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts
Logamax Plus GB022 boiler 84 workm active time time (>=0<=16777213) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm
Logamax Plus GB022 boiler 84 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower
Logamax Plus GB022 boiler 84 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal
Logamax Plus GB022 boiler 84 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat
Logamax Plus GB022 boiler 84 nrgdhw energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrgdhw
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 summertemp summer temperature uint8 (>=0<=30) C True number.boiler_summer_temperature number.boiler_summertemp
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 meterdhw meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 gasmeterdhw gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeterdhw
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 nrgdhw2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrgdhw2
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 setpumppower set pump power uint8 (>=0<=100) % False sensor.boiler_dhw_set_pump_power sensor.boiler_dhw_setpumppower
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 starts starts uint24 (>=0<=16777213) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 workm active time time (>=0<=16777213) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 nrgdhw energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrgdhw
Topline/GB162 boiler 115 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
Topline/GB162 boiler 115 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
Topline/GB162 boiler 115 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
Topline/GB162 boiler 115 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
Topline/GB162 boiler 115 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
Topline/GB162 boiler 115 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
Topline/GB162 boiler 115 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
Topline/GB162 boiler 115 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
Topline/GB162 boiler 115 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
Topline/GB162 boiler 115 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
Topline/GB162 boiler 115 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
Topline/GB162 boiler 115 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
Topline/GB162 boiler 115 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
Topline/GB162 boiler 115 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp
Topline/GB162 boiler 115 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas
Topline/GB162 boiler 115 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2
Topline/GB162 boiler 115 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr
Topline/GB162 boiler 115 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork
Topline/GB162 boiler 115 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork
Topline/GB162 boiler 115 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat
Topline/GB162 boiler 115 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower
Topline/GB162 boiler 115 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower
Topline/GB162 boiler 115 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod
Topline/GB162 boiler 115 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow
Topline/GB162 boiler 115 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock
Topline/GB162 boiler 115 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston
Topline/GB162 boiler 115 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff
Topline/GB162 boiler 115 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston
Topline/GB162 boiler 115 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff
Topline/GB162 boiler 115 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon
Topline/GB162 boiler 115 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase
Topline/GB162 boiler 115 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend
Topline/GB162 boiler 115 summertemp summer temperature uint8 (>=0<=30) C True number.boiler_summer_temperature number.boiler_summertemp
Topline/GB162 boiler 115 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode
Topline/GB162 boiler 115 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp
Topline/GB162 boiler 115 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
Topline/GB162 boiler 115 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
Topline/GB162 boiler 115 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
Topline/GB162 boiler 115 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
Topline/GB162 boiler 115 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
Topline/GB162 boiler 115 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
Topline/GB162 boiler 115 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
Topline/GB162 boiler 115 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
Topline/GB162 boiler 115 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
Topline/GB162 boiler 115 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
Topline/GB162 boiler 115 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
Topline/GB162 boiler 115 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
Topline/GB162 boiler 115 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
Topline/GB162 boiler 115 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
Topline/GB162 boiler 115 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
Topline/GB162 boiler 115 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
Topline/GB162 boiler 115 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
Topline/GB162 boiler 115 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
Topline/GB162 boiler 115 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
Topline/GB162 boiler 115 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
Topline/GB162 boiler 115 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
Topline/GB162 boiler 115 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
Topline/GB162 boiler 115 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
Topline/GB162 boiler 115 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
Topline/GB162 boiler 115 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
Topline/GB162 boiler 115 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
Topline/GB162 boiler 115 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
Topline/GB162 boiler 115 meterdhw meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
Topline/GB162 boiler 115 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat
Topline/GB162 boiler 115 gasmeterdhw gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeterdhw
Topline/GB162 boiler 115 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2
Topline/GB162 boiler 115 nrgdhw2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrgdhw2
Topline/GB162 boiler 115 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
Topline/GB162 boiler 115 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
Topline/GB162 boiler 115 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
Topline/GB162 boiler 115 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
Topline/GB162 boiler 115 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
Topline/GB162 boiler 115 seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff
Topline/GB162 boiler 115 seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle
Topline/GB162 boiler 115 solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp
Topline/GB162 boiler 115 type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type
Topline/GB162 boiler 115 comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort
Topline/GB162 boiler 115 comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1
Topline/GB162 boiler 115 flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset
Topline/GB162 boiler 115 chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization
Topline/GB162 boiler 115 maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower
Topline/GB162 boiler 115 maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp
Topline/GB162 boiler 115 circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump
Topline/GB162 boiler 115 chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype
Topline/GB162 boiler 115 hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston
Topline/GB162 boiler 115 hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff
Topline/GB162 boiler 115 disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp
Topline/GB162 boiler 115 circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode
Topline/GB162 boiler 115 circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ
Topline/GB162 boiler 115 curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp
Topline/GB162 boiler 115 curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2
Topline/GB162 boiler 115 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
Topline/GB162 boiler 115 storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1
Topline/GB162 boiler 115 storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2
Topline/GB162 boiler 115 activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated
Topline/GB162 boiler 115 onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime
Topline/GB162 boiler 115 disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting
Topline/GB162 boiler 115 charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging
Topline/GB162 boiler 115 recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging
Topline/GB162 boiler 115 tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok
Topline/GB162 boiler 115 active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active
Topline/GB162 boiler 115 3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve
Topline/GB162 boiler 115 setpumppower set pump power uint8 (>=0<=100) % False sensor.boiler_dhw_set_pump_power sensor.boiler_dhw_setpumppower
Topline/GB162 boiler 115 mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp
Topline/GB162 boiler 115 cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp
Topline/GB162 boiler 115 starts starts uint24 (>=0<=16777213) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts
Topline/GB162 boiler 115 workm active time time (>=0<=16777213) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm
Topline/GB162 boiler 115 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower
Topline/GB162 boiler 115 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal
Topline/GB162 boiler 115 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat
Topline/GB162 boiler 115 nrgdhw energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrgdhw
Cascade MCM10 boiler 121 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
Cascade MCM10 boiler 121 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
Cascade MCM10 boiler 121 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
Cascade MCM10 boiler 121 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
Cascade MCM10 boiler 121 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
Cascade MCM10 boiler 121 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
Cascade MCM10 boiler 121 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
Cascade MCM10 boiler 121 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
Cascade MCM10 boiler 121 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
Cascade MCM10 boiler 121 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
Cascade MCM10 boiler 121 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
Cascade MCM10 boiler 121 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
Cascade MCM10 boiler 121 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
Cascade MCM10 boiler 121 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp
Cascade MCM10 boiler 121 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas
Cascade MCM10 boiler 121 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2
Cascade MCM10 boiler 121 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr
Cascade MCM10 boiler 121 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork
Cascade MCM10 boiler 121 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork
Cascade MCM10 boiler 121 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat
Cascade MCM10 boiler 121 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower
Cascade MCM10 boiler 121 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower
Cascade MCM10 boiler 121 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod
Cascade MCM10 boiler 121 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow
Cascade MCM10 boiler 121 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock
Cascade MCM10 boiler 121 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston
Cascade MCM10 boiler 121 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff
Cascade MCM10 boiler 121 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston
Cascade MCM10 boiler 121 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff
Cascade MCM10 boiler 121 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon
Cascade MCM10 boiler 121 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase
Cascade MCM10 boiler 121 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend
Cascade MCM10 boiler 121 summertemp summer temperature uint8 (>=0<=30) C True number.boiler_summer_temperature number.boiler_summertemp
Cascade MCM10 boiler 121 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode
Cascade MCM10 boiler 121 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp
Cascade MCM10 boiler 121 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
Cascade MCM10 boiler 121 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
Cascade MCM10 boiler 121 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
Cascade MCM10 boiler 121 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
Cascade MCM10 boiler 121 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
Cascade MCM10 boiler 121 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
Cascade MCM10 boiler 121 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
Cascade MCM10 boiler 121 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
Cascade MCM10 boiler 121 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
Cascade MCM10 boiler 121 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
Cascade MCM10 boiler 121 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
Cascade MCM10 boiler 121 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
Cascade MCM10 boiler 121 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
Cascade MCM10 boiler 121 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
Cascade MCM10 boiler 121 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
Cascade MCM10 boiler 121 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
Cascade MCM10 boiler 121 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
Cascade MCM10 boiler 121 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
Cascade MCM10 boiler 121 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
Cascade MCM10 boiler 121 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
Cascade MCM10 boiler 121 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
Cascade MCM10 boiler 121 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
Cascade MCM10 boiler 121 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
Cascade MCM10 boiler 121 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
Cascade MCM10 boiler 121 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
Cascade MCM10 boiler 121 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
Cascade MCM10 boiler 121 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
Cascade MCM10 boiler 121 meterdhw meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
Cascade MCM10 boiler 121 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat
Cascade MCM10 boiler 121 gasmeterdhw gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeterdhw
Cascade MCM10 boiler 121 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2
Cascade MCM10 boiler 121 nrgdhw2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrgdhw2
Cascade MCM10 boiler 121 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
Cascade MCM10 boiler 121 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
Cascade MCM10 boiler 121 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
Cascade MCM10 boiler 121 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
Cascade MCM10 boiler 121 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
Cascade MCM10 boiler 121 seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff
Cascade MCM10 boiler 121 seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle
Cascade MCM10 boiler 121 solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp
Cascade MCM10 boiler 121 type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type
Cascade MCM10 boiler 121 comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort
Cascade MCM10 boiler 121 comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1
Cascade MCM10 boiler 121 flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset
Cascade MCM10 boiler 121 chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization
Cascade MCM10 boiler 121 maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower
Cascade MCM10 boiler 121 maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp
Cascade MCM10 boiler 121 circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump
Cascade MCM10 boiler 121 chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype
Cascade MCM10 boiler 121 hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston
Cascade MCM10 boiler 121 hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff
Cascade MCM10 boiler 121 disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp
Cascade MCM10 boiler 121 circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode
Cascade MCM10 boiler 121 circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ
Cascade MCM10 boiler 121 curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp
Cascade MCM10 boiler 121 curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2
Cascade MCM10 boiler 121 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
Cascade MCM10 boiler 121 storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1
Cascade MCM10 boiler 121 storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2
Cascade MCM10 boiler 121 activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated
Cascade MCM10 boiler 121 onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime
Cascade MCM10 boiler 121 disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting
Cascade MCM10 boiler 121 charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging
Cascade MCM10 boiler 121 recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging
Cascade MCM10 boiler 121 tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok
Cascade MCM10 boiler 121 active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active
Cascade MCM10 boiler 121 3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve
Cascade MCM10 boiler 121 setpumppower set pump power uint8 (>=0<=100) % False sensor.boiler_dhw_set_pump_power sensor.boiler_dhw_setpumppower
Cascade MCM10 boiler 121 mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp
Cascade MCM10 boiler 121 cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp
Cascade MCM10 boiler 121 starts starts uint24 (>=0<=16777213) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts
Cascade MCM10 boiler 121 workm active time time (>=0<=16777213) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm
Cascade MCM10 boiler 121 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower
Cascade MCM10 boiler 121 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal
Cascade MCM10 boiler 121 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat
Cascade MCM10 boiler 121 nrgdhw energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrgdhw
Proline boiler 122 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
Proline boiler 122 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
Proline boiler 122 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
Proline boiler 122 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
Proline boiler 122 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
Proline boiler 122 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
Proline boiler 122 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
Proline boiler 122 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
Proline boiler 122 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
Proline boiler 122 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
Proline boiler 122 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
Proline boiler 122 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
Proline boiler 122 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
Proline boiler 122 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp
Proline boiler 122 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas
Proline boiler 122 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2
Proline boiler 122 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr
Proline boiler 122 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork
Proline boiler 122 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork
Proline boiler 122 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat
Proline boiler 122 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower
Proline boiler 122 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower
Proline boiler 122 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod
Proline boiler 122 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow
Proline boiler 122 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock
Proline boiler 122 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston
Proline boiler 122 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff
Proline boiler 122 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston
Proline boiler 122 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff
Proline boiler 122 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon
Proline boiler 122 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase
Proline boiler 122 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend
Proline boiler 122 summertemp summer temperature uint8 (>=0<=30) C True number.boiler_summer_temperature number.boiler_summertemp
Proline boiler 122 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode
Proline boiler 122 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp
Proline boiler 122 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
Proline boiler 122 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
Proline boiler 122 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
Proline boiler 122 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
Proline boiler 122 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
Proline boiler 122 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
Proline boiler 122 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
Proline boiler 122 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
Proline boiler 122 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
Proline boiler 122 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
Proline boiler 122 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
Proline boiler 122 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
Proline boiler 122 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
Proline boiler 122 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
Proline boiler 122 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
Proline boiler 122 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
Proline boiler 122 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
Proline boiler 122 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
Proline boiler 122 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
Proline boiler 122 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
Proline boiler 122 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
Proline boiler 122 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
Proline boiler 122 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
Proline boiler 122 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
Proline boiler 122 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
Proline boiler 122 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
Proline boiler 122 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
Proline boiler 122 meterdhw meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
Proline boiler 122 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat
Proline boiler 122 gasmeterdhw gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeterdhw
Proline boiler 122 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2
Proline boiler 122 nrgdhw2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrgdhw2
Proline boiler 122 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
Proline boiler 122 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
Proline boiler 122 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
Proline boiler 122 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
Proline boiler 122 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
Proline boiler 122 seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff
Proline boiler 122 seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle
Proline boiler 122 solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp
Proline boiler 122 type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type
Proline boiler 122 comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort
Proline boiler 122 comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1
Proline boiler 122 flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset
Proline boiler 122 chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization
Proline boiler 122 maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower
Proline boiler 122 maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp
Proline boiler 122 circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump
Proline boiler 122 chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype
Proline boiler 122 hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston
Proline boiler 122 hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff
Proline boiler 122 disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp
Proline boiler 122 circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode
Proline boiler 122 circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ
Proline boiler 122 curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp
Proline boiler 122 curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2
Proline boiler 122 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
Proline boiler 122 storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1
Proline boiler 122 storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2
Proline boiler 122 activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated
Proline boiler 122 onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime
Proline boiler 122 disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting
Proline boiler 122 charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging
Proline boiler 122 recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging
Proline boiler 122 tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok
Proline boiler 122 active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active
Proline boiler 122 3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve
Proline boiler 122 setpumppower set pump power uint8 (>=0<=100) % False sensor.boiler_dhw_set_pump_power sensor.boiler_dhw_setpumppower
Proline boiler 122 mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp
Proline boiler 122 cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp
Proline boiler 122 starts starts uint24 (>=0<=16777213) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts
Proline boiler 122 workm active time time (>=0<=16777213) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm
Proline boiler 122 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower
Proline boiler 122 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal
Proline boiler 122 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat
Proline boiler 122 nrgdhw energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrgdhw
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 summertemp summer temperature uint8 (>=0<=30) C True number.boiler_summer_temperature number.boiler_summertemp
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 meterdhw meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 gasmeterdhw gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeterdhw
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 nrgdhw2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrgdhw2
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 setpumppower set pump power uint8 (>=0<=100) % False sensor.boiler_dhw_set_pump_power sensor.boiler_dhw_setpumppower
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 starts starts uint24 (>=0<=16777213) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 workm active time time (>=0<=16777213) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 nrgdhw energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrgdhw
GB212 boiler 131 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
GB212 boiler 131 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
GB212 boiler 131 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
GB212 boiler 131 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
GB212 boiler 131 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
GB212 boiler 131 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
GB212 boiler 131 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
GB212 boiler 131 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
GB212 boiler 131 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
GB212 boiler 131 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
GB212 boiler 131 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
GB212 boiler 131 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
GB212 boiler 131 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
GB212 boiler 131 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp
GB212 boiler 131 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas
GB212 boiler 131 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2
GB212 boiler 131 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr
GB212 boiler 131 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork
GB212 boiler 131 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork
GB212 boiler 131 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat
GB212 boiler 131 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower
GB212 boiler 131 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower
GB212 boiler 131 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod
GB212 boiler 131 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow
GB212 boiler 131 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock
GB212 boiler 131 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston
GB212 boiler 131 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff
GB212 boiler 131 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston
GB212 boiler 131 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff
GB212 boiler 131 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon
GB212 boiler 131 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase
GB212 boiler 131 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend
GB212 boiler 131 summertemp summer temperature uint8 (>=0<=30) C True number.boiler_summer_temperature number.boiler_summertemp
GB212 boiler 131 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode
GB212 boiler 131 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp
GB212 boiler 131 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
GB212 boiler 131 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
GB212 boiler 131 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
GB212 boiler 131 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
GB212 boiler 131 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
GB212 boiler 131 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
GB212 boiler 131 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
GB212 boiler 131 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
GB212 boiler 131 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
GB212 boiler 131 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
GB212 boiler 131 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
GB212 boiler 131 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
GB212 boiler 131 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
GB212 boiler 131 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
GB212 boiler 131 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
GB212 boiler 131 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
GB212 boiler 131 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
GB212 boiler 131 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
GB212 boiler 131 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
GB212 boiler 131 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
GB212 boiler 131 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
GB212 boiler 131 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
GB212 boiler 131 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
GB212 boiler 131 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
GB212 boiler 131 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
GB212 boiler 131 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
GB212 boiler 131 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
GB212 boiler 131 meterdhw meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
GB212 boiler 131 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat
GB212 boiler 131 gasmeterdhw gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeterdhw
GB212 boiler 131 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2
GB212 boiler 131 nrgdhw2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrgdhw2
GB212 boiler 131 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
GB212 boiler 131 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
GB212 boiler 131 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
GB212 boiler 131 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
GB212 boiler 131 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
GB212 boiler 131 seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff
GB212 boiler 131 seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle
GB212 boiler 131 solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp
GB212 boiler 131 type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type
GB212 boiler 131 comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort
GB212 boiler 131 comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1
GB212 boiler 131 flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset
GB212 boiler 131 chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization
GB212 boiler 131 maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower
GB212 boiler 131 maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp
GB212 boiler 131 circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump
GB212 boiler 131 chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype
GB212 boiler 131 hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston
GB212 boiler 131 hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff
GB212 boiler 131 disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp
GB212 boiler 131 circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode
GB212 boiler 131 circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ
GB212 boiler 131 curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp
GB212 boiler 131 curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2
GB212 boiler 131 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
GB212 boiler 131 storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1
GB212 boiler 131 storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2
GB212 boiler 131 activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated
GB212 boiler 131 onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime
GB212 boiler 131 disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting
GB212 boiler 131 charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging
GB212 boiler 131 recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging
GB212 boiler 131 tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok
GB212 boiler 131 active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active
GB212 boiler 131 3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve
GB212 boiler 131 setpumppower set pump power uint8 (>=0<=100) % False sensor.boiler_dhw_set_pump_power sensor.boiler_dhw_setpumppower
GB212 boiler 131 mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp
GB212 boiler 131 cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp
GB212 boiler 131 starts starts uint24 (>=0<=16777213) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts
GB212 boiler 131 workm active time time (>=0<=16777213) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm
GB212 boiler 131 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower
GB212 boiler 131 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal
GB212 boiler 131 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat
GB212 boiler 131 nrgdhw energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrgdhw
GC7000F boiler 132 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
GC7000F boiler 132 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
GC7000F boiler 132 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
GC7000F boiler 132 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
GC7000F boiler 132 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
GC7000F boiler 132 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
GC7000F boiler 132 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
GC7000F boiler 132 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
GC7000F boiler 132 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
GC7000F boiler 132 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
GC7000F boiler 132 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
GC7000F boiler 132 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
GC7000F boiler 132 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
GC7000F boiler 132 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp
GC7000F boiler 132 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas
GC7000F boiler 132 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2
GC7000F boiler 132 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr
GC7000F boiler 132 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork
GC7000F boiler 132 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork
GC7000F boiler 132 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat
GC7000F boiler 132 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower
GC7000F boiler 132 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower
GC7000F boiler 132 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod
GC7000F boiler 132 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow
GC7000F boiler 132 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock
GC7000F boiler 132 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston
GC7000F boiler 132 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff
GC7000F boiler 132 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston
GC7000F boiler 132 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff
GC7000F boiler 132 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon
GC7000F boiler 132 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase
GC7000F boiler 132 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend
GC7000F boiler 132 summertemp summer temperature uint8 (>=0<=30) C True number.boiler_summer_temperature number.boiler_summertemp
GC7000F boiler 132 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode
GC7000F boiler 132 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp
GC7000F boiler 132 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
GC7000F boiler 132 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
GC7000F boiler 132 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
GC7000F boiler 132 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
GC7000F boiler 132 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
GC7000F boiler 132 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
GC7000F boiler 132 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
GC7000F boiler 132 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
GC7000F boiler 132 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
GC7000F boiler 132 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
GC7000F boiler 132 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
GC7000F boiler 132 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
GC7000F boiler 132 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
GC7000F boiler 132 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
GC7000F boiler 132 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
GC7000F boiler 132 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
GC7000F boiler 132 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
GC7000F boiler 132 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
GC7000F boiler 132 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
GC7000F boiler 132 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
GC7000F boiler 132 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
GC7000F boiler 132 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
GC7000F boiler 132 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
GC7000F boiler 132 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
GC7000F boiler 132 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
GC7000F boiler 132 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
GC7000F boiler 132 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
GC7000F boiler 132 meterdhw meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
GC7000F boiler 132 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat
GC7000F boiler 132 gasmeterdhw gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeterdhw
GC7000F boiler 132 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2
GC7000F boiler 132 nrgdhw2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrgdhw2
GC7000F boiler 132 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
GC7000F boiler 132 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
GC7000F boiler 132 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
GC7000F boiler 132 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
GC7000F boiler 132 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
GC7000F boiler 132 seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff
GC7000F boiler 132 seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle
GC7000F boiler 132 solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp
GC7000F boiler 132 type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type
GC7000F boiler 132 comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort
GC7000F boiler 132 comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1
GC7000F boiler 132 flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset
GC7000F boiler 132 chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization
GC7000F boiler 132 maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower
GC7000F boiler 132 maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp
GC7000F boiler 132 circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump
GC7000F boiler 132 chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype
GC7000F boiler 132 hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston
GC7000F boiler 132 hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff
GC7000F boiler 132 disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp
GC7000F boiler 132 circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode
GC7000F boiler 132 circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ
GC7000F boiler 132 curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp
GC7000F boiler 132 curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2
GC7000F boiler 132 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
GC7000F boiler 132 storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1
GC7000F boiler 132 storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2
GC7000F boiler 132 activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated
GC7000F boiler 132 onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime
GC7000F boiler 132 disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting
GC7000F boiler 132 charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging
GC7000F boiler 132 recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging
GC7000F boiler 132 tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok
GC7000F boiler 132 active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active
GC7000F boiler 132 3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve
GC7000F boiler 132 setpumppower set pump power uint8 (>=0<=100) % False sensor.boiler_dhw_set_pump_power sensor.boiler_dhw_setpumppower
GC7000F boiler 132 mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp
GC7000F boiler 132 cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp
GC7000F boiler 132 starts starts uint24 (>=0<=16777213) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts
GC7000F boiler 132 workm active time time (>=0<=16777213) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm
GC7000F boiler 132 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower
GC7000F boiler 132 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal
GC7000F boiler 132 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat
GC7000F boiler 132 nrgdhw energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrgdhw
Logano GB125/KB195i/Logamatic MC110 boiler 133 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
Logano GB125/KB195i/Logamatic MC110 boiler 133 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
Logano GB125/KB195i/Logamatic MC110 boiler 133 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
Logano GB125/KB195i/Logamatic MC110 boiler 133 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
Logano GB125/KB195i/Logamatic MC110 boiler 133 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
Logano GB125/KB195i/Logamatic MC110 boiler 133 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
Logano GB125/KB195i/Logamatic MC110 boiler 133 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
Logano GB125/KB195i/Logamatic MC110 boiler 133 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
Logano GB125/KB195i/Logamatic MC110 boiler 133 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
Logano GB125/KB195i/Logamatic MC110 boiler 133 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
Logano GB125/KB195i/Logamatic MC110 boiler 133 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
Logano GB125/KB195i/Logamatic MC110 boiler 133 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
Logano GB125/KB195i/Logamatic MC110 boiler 133 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
Logano GB125/KB195i/Logamatic MC110 boiler 133 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp
Logano GB125/KB195i/Logamatic MC110 boiler 133 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas
Logano GB125/KB195i/Logamatic MC110 boiler 133 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2
Logano GB125/KB195i/Logamatic MC110 boiler 133 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr
Logano GB125/KB195i/Logamatic MC110 boiler 133 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork
Logano GB125/KB195i/Logamatic MC110 boiler 133 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork
Logano GB125/KB195i/Logamatic MC110 boiler 133 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat
Logano GB125/KB195i/Logamatic MC110 boiler 133 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower
Logano GB125/KB195i/Logamatic MC110 boiler 133 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower
Logano GB125/KB195i/Logamatic MC110 boiler 133 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod
Logano GB125/KB195i/Logamatic MC110 boiler 133 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow
Logano GB125/KB195i/Logamatic MC110 boiler 133 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock
Logano GB125/KB195i/Logamatic MC110 boiler 133 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston
Logano GB125/KB195i/Logamatic MC110 boiler 133 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff
Logano GB125/KB195i/Logamatic MC110 boiler 133 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston
Logano GB125/KB195i/Logamatic MC110 boiler 133 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff
Logano GB125/KB195i/Logamatic MC110 boiler 133 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon
Logano GB125/KB195i/Logamatic MC110 boiler 133 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase
Logano GB125/KB195i/Logamatic MC110 boiler 133 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend
Logano GB125/KB195i/Logamatic MC110 boiler 133 summertemp summer temperature uint8 (>=0<=30) C True number.boiler_summer_temperature number.boiler_summertemp
Logano GB125/KB195i/Logamatic MC110 boiler 133 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode
Logano GB125/KB195i/Logamatic MC110 boiler 133 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp
Logano GB125/KB195i/Logamatic MC110 boiler 133 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
Logano GB125/KB195i/Logamatic MC110 boiler 133 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
Logano GB125/KB195i/Logamatic MC110 boiler 133 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
Logano GB125/KB195i/Logamatic MC110 boiler 133 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
Logano GB125/KB195i/Logamatic MC110 boiler 133 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
Logano GB125/KB195i/Logamatic MC110 boiler 133 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
Logano GB125/KB195i/Logamatic MC110 boiler 133 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
Logano GB125/KB195i/Logamatic MC110 boiler 133 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
Logano GB125/KB195i/Logamatic MC110 boiler 133 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
Logano GB125/KB195i/Logamatic MC110 boiler 133 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
Logano GB125/KB195i/Logamatic MC110 boiler 133 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
Logano GB125/KB195i/Logamatic MC110 boiler 133 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
Logano GB125/KB195i/Logamatic MC110 boiler 133 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
Logano GB125/KB195i/Logamatic MC110 boiler 133 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
Logano GB125/KB195i/Logamatic MC110 boiler 133 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
Logano GB125/KB195i/Logamatic MC110 boiler 133 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
Logano GB125/KB195i/Logamatic MC110 boiler 133 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
Logano GB125/KB195i/Logamatic MC110 boiler 133 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
Logano GB125/KB195i/Logamatic MC110 boiler 133 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
Logano GB125/KB195i/Logamatic MC110 boiler 133 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
Logano GB125/KB195i/Logamatic MC110 boiler 133 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
Logano GB125/KB195i/Logamatic MC110 boiler 133 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
Logano GB125/KB195i/Logamatic MC110 boiler 133 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
Logano GB125/KB195i/Logamatic MC110 boiler 133 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
Logano GB125/KB195i/Logamatic MC110 boiler 133 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
Logano GB125/KB195i/Logamatic MC110 boiler 133 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
Logano GB125/KB195i/Logamatic MC110 boiler 133 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
Logano GB125/KB195i/Logamatic MC110 boiler 133 meterdhw meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
Logano GB125/KB195i/Logamatic MC110 boiler 133 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat
Logano GB125/KB195i/Logamatic MC110 boiler 133 gasmeterdhw gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeterdhw
Logano GB125/KB195i/Logamatic MC110 boiler 133 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2
Logano GB125/KB195i/Logamatic MC110 boiler 133 nrgdhw2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrgdhw2
Logano GB125/KB195i/Logamatic MC110 boiler 133 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
Logano GB125/KB195i/Logamatic MC110 boiler 133 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
Logano GB125/KB195i/Logamatic MC110 boiler 133 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
Logano GB125/KB195i/Logamatic MC110 boiler 133 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
Logano GB125/KB195i/Logamatic MC110 boiler 133 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
Logano GB125/KB195i/Logamatic MC110 boiler 133 seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff
Logano GB125/KB195i/Logamatic MC110 boiler 133 seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle
Logano GB125/KB195i/Logamatic MC110 boiler 133 solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp
Logano GB125/KB195i/Logamatic MC110 boiler 133 type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type
Logano GB125/KB195i/Logamatic MC110 boiler 133 comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort
Logano GB125/KB195i/Logamatic MC110 boiler 133 comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1
Logano GB125/KB195i/Logamatic MC110 boiler 133 flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset
Logano GB125/KB195i/Logamatic MC110 boiler 133 chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization
Logano GB125/KB195i/Logamatic MC110 boiler 133 maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower
Logano GB125/KB195i/Logamatic MC110 boiler 133 maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp
Logano GB125/KB195i/Logamatic MC110 boiler 133 circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump
Logano GB125/KB195i/Logamatic MC110 boiler 133 chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype
Logano GB125/KB195i/Logamatic MC110 boiler 133 hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston
Logano GB125/KB195i/Logamatic MC110 boiler 133 hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff
Logano GB125/KB195i/Logamatic MC110 boiler 133 disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp
Logano GB125/KB195i/Logamatic MC110 boiler 133 circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode
Logano GB125/KB195i/Logamatic MC110 boiler 133 circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ
Logano GB125/KB195i/Logamatic MC110 boiler 133 curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp
Logano GB125/KB195i/Logamatic MC110 boiler 133 curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2
Logano GB125/KB195i/Logamatic MC110 boiler 133 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
Logano GB125/KB195i/Logamatic MC110 boiler 133 storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1
Logano GB125/KB195i/Logamatic MC110 boiler 133 storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2
Logano GB125/KB195i/Logamatic MC110 boiler 133 activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated
Logano GB125/KB195i/Logamatic MC110 boiler 133 onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime
Logano GB125/KB195i/Logamatic MC110 boiler 133 disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting
Logano GB125/KB195i/Logamatic MC110 boiler 133 charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging
Logano GB125/KB195i/Logamatic MC110 boiler 133 recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging
Logano GB125/KB195i/Logamatic MC110 boiler 133 tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok
Logano GB125/KB195i/Logamatic MC110 boiler 133 active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active
Logano GB125/KB195i/Logamatic MC110 boiler 133 3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve
Logano GB125/KB195i/Logamatic MC110 boiler 133 setpumppower set pump power uint8 (>=0<=100) % False sensor.boiler_dhw_set_pump_power sensor.boiler_dhw_setpumppower
Logano GB125/KB195i/Logamatic MC110 boiler 133 mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp
Logano GB125/KB195i/Logamatic MC110 boiler 133 cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp
Logano GB125/KB195i/Logamatic MC110 boiler 133 starts starts uint24 (>=0<=16777213) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts
Logano GB125/KB195i/Logamatic MC110 boiler 133 workm active time time (>=0<=16777213) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm
Logano GB125/KB195i/Logamatic MC110 boiler 133 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower
Logano GB125/KB195i/Logamatic MC110 boiler 133 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal
Logano GB125/KB195i/Logamatic MC110 boiler 133 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat
Logano GB125/KB195i/Logamatic MC110 boiler 133 nrgdhw energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrgdhw
Greenstar 30Ri Compact boiler 154 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
Greenstar 30Ri Compact boiler 154 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
Greenstar 30Ri Compact boiler 154 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
Greenstar 30Ri Compact boiler 154 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
Greenstar 30Ri Compact boiler 154 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
Greenstar 30Ri Compact boiler 154 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
Greenstar 30Ri Compact boiler 154 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
Greenstar 30Ri Compact boiler 154 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
Greenstar 30Ri Compact boiler 154 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
Greenstar 30Ri Compact boiler 154 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
Greenstar 30Ri Compact boiler 154 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
Greenstar 30Ri Compact boiler 154 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
Greenstar 30Ri Compact boiler 154 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
Greenstar 30Ri Compact boiler 154 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp
Greenstar 30Ri Compact boiler 154 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas
Greenstar 30Ri Compact boiler 154 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2
Greenstar 30Ri Compact boiler 154 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr
Greenstar 30Ri Compact boiler 154 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork
Greenstar 30Ri Compact boiler 154 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork
Greenstar 30Ri Compact boiler 154 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat
Greenstar 30Ri Compact boiler 154 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower
Greenstar 30Ri Compact boiler 154 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower
Greenstar 30Ri Compact boiler 154 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod
Greenstar 30Ri Compact boiler 154 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow
Greenstar 30Ri Compact boiler 154 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock
Greenstar 30Ri Compact boiler 154 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston
Greenstar 30Ri Compact boiler 154 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff
Greenstar 30Ri Compact boiler 154 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston
Greenstar 30Ri Compact boiler 154 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff
Greenstar 30Ri Compact boiler 154 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon
Greenstar 30Ri Compact boiler 154 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase
Greenstar 30Ri Compact boiler 154 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend
Greenstar 30Ri Compact boiler 154 summertemp summer temperature uint8 (>=0<=30) C True number.boiler_summer_temperature number.boiler_summertemp
Greenstar 30Ri Compact boiler 154 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode
Greenstar 30Ri Compact boiler 154 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp
Greenstar 30Ri Compact boiler 154 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
Greenstar 30Ri Compact boiler 154 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
Greenstar 30Ri Compact boiler 154 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
Greenstar 30Ri Compact boiler 154 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
Greenstar 30Ri Compact boiler 154 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
Greenstar 30Ri Compact boiler 154 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
Greenstar 30Ri Compact boiler 154 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
Greenstar 30Ri Compact boiler 154 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
Greenstar 30Ri Compact boiler 154 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
Greenstar 30Ri Compact boiler 154 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
Greenstar 30Ri Compact boiler 154 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
Greenstar 30Ri Compact boiler 154 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
Greenstar 30Ri Compact boiler 154 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
Greenstar 30Ri Compact boiler 154 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
Greenstar 30Ri Compact boiler 154 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
Greenstar 30Ri Compact boiler 154 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
Greenstar 30Ri Compact boiler 154 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
Greenstar 30Ri Compact boiler 154 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
Greenstar 30Ri Compact boiler 154 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
Greenstar 30Ri Compact boiler 154 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
Greenstar 30Ri Compact boiler 154 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
Greenstar 30Ri Compact boiler 154 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
Greenstar 30Ri Compact boiler 154 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
Greenstar 30Ri Compact boiler 154 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
Greenstar 30Ri Compact boiler 154 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
Greenstar 30Ri Compact boiler 154 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
Greenstar 30Ri Compact boiler 154 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
Greenstar 30Ri Compact boiler 154 meterdhw meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
Greenstar 30Ri Compact boiler 154 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat
Greenstar 30Ri Compact boiler 154 gasmeterdhw gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeterdhw
Greenstar 30Ri Compact boiler 154 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2
Greenstar 30Ri Compact boiler 154 nrgdhw2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrgdhw2
Greenstar 30Ri Compact boiler 154 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
Greenstar 30Ri Compact boiler 154 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
Greenstar 30Ri Compact boiler 154 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
Greenstar 30Ri Compact boiler 154 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
Greenstar 30Ri Compact boiler 154 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
Greenstar 30Ri Compact boiler 154 seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff
Greenstar 30Ri Compact boiler 154 seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle
Greenstar 30Ri Compact boiler 154 solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp
Greenstar 30Ri Compact boiler 154 type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type
Greenstar 30Ri Compact boiler 154 comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort
Greenstar 30Ri Compact boiler 154 comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1
Greenstar 30Ri Compact boiler 154 flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset
Greenstar 30Ri Compact boiler 154 chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization
Greenstar 30Ri Compact boiler 154 maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower
Greenstar 30Ri Compact boiler 154 maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp
Greenstar 30Ri Compact boiler 154 circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump
Greenstar 30Ri Compact boiler 154 chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype
Greenstar 30Ri Compact boiler 154 hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston
Greenstar 30Ri Compact boiler 154 hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff
Greenstar 30Ri Compact boiler 154 disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp
Greenstar 30Ri Compact boiler 154 circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode
Greenstar 30Ri Compact boiler 154 circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ
Greenstar 30Ri Compact boiler 154 curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp
Greenstar 30Ri Compact boiler 154 curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2
Greenstar 30Ri Compact boiler 154 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
Greenstar 30Ri Compact boiler 154 storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1
Greenstar 30Ri Compact boiler 154 storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2
Greenstar 30Ri Compact boiler 154 activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated
Greenstar 30Ri Compact boiler 154 onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime
Greenstar 30Ri Compact boiler 154 disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting
Greenstar 30Ri Compact boiler 154 charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging
Greenstar 30Ri Compact boiler 154 recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging
Greenstar 30Ri Compact boiler 154 tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok
Greenstar 30Ri Compact boiler 154 active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active
Greenstar 30Ri Compact boiler 154 3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve
Greenstar 30Ri Compact boiler 154 setpumppower set pump power uint8 (>=0<=100) % False sensor.boiler_dhw_set_pump_power sensor.boiler_dhw_setpumppower
Greenstar 30Ri Compact boiler 154 mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp
Greenstar 30Ri Compact boiler 154 cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp
Greenstar 30Ri Compact boiler 154 starts starts uint24 (>=0<=16777213) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts
Greenstar 30Ri Compact boiler 154 workm active time time (>=0<=16777213) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm
Greenstar 30Ri Compact boiler 154 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower
Greenstar 30Ri Compact boiler 154 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal
Greenstar 30Ri Compact boiler 154 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat
Greenstar 30Ri Compact boiler 154 nrgdhw energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrgdhw
Cerapur Aero boiler 167 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
Cerapur Aero boiler 167 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
Cerapur Aero boiler 167 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
Cerapur Aero boiler 167 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
Cerapur Aero boiler 167 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
Cerapur Aero boiler 167 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
Cerapur Aero boiler 167 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
Cerapur Aero boiler 167 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
Cerapur Aero boiler 167 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
Cerapur Aero boiler 167 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
Cerapur Aero boiler 167 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
Cerapur Aero boiler 167 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
Cerapur Aero boiler 167 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
Cerapur Aero boiler 167 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp
Cerapur Aero boiler 167 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas
Cerapur Aero boiler 167 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2
Cerapur Aero boiler 167 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr
Cerapur Aero boiler 167 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork
Cerapur Aero boiler 167 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork
Cerapur Aero boiler 167 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat
Cerapur Aero boiler 167 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower
Cerapur Aero boiler 167 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower
Cerapur Aero boiler 167 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod
Cerapur Aero boiler 167 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow
Cerapur Aero boiler 167 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock
Cerapur Aero boiler 167 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston
Cerapur Aero boiler 167 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff
Cerapur Aero boiler 167 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston
Cerapur Aero boiler 167 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff
Cerapur Aero boiler 167 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon
Cerapur Aero boiler 167 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase
Cerapur Aero boiler 167 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend
Cerapur Aero boiler 167 summertemp summer temperature uint8 (>=0<=30) C True number.boiler_summer_temperature number.boiler_summertemp
Cerapur Aero boiler 167 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode
Cerapur Aero boiler 167 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp
Cerapur Aero boiler 167 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
Cerapur Aero boiler 167 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
Cerapur Aero boiler 167 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
Cerapur Aero boiler 167 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
Cerapur Aero boiler 167 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
Cerapur Aero boiler 167 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
Cerapur Aero boiler 167 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
Cerapur Aero boiler 167 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
Cerapur Aero boiler 167 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
Cerapur Aero boiler 167 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
Cerapur Aero boiler 167 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
Cerapur Aero boiler 167 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
Cerapur Aero boiler 167 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
Cerapur Aero boiler 167 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
Cerapur Aero boiler 167 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
Cerapur Aero boiler 167 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
Cerapur Aero boiler 167 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
Cerapur Aero boiler 167 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
Cerapur Aero boiler 167 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
Cerapur Aero boiler 167 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
Cerapur Aero boiler 167 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
Cerapur Aero boiler 167 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
Cerapur Aero boiler 167 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
Cerapur Aero boiler 167 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
Cerapur Aero boiler 167 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
Cerapur Aero boiler 167 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
Cerapur Aero boiler 167 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
Cerapur Aero boiler 167 meterdhw meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
Cerapur Aero boiler 167 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat
Cerapur Aero boiler 167 gasmeterdhw gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeterdhw
Cerapur Aero boiler 167 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2
Cerapur Aero boiler 167 nrgdhw2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrgdhw2
Cerapur Aero boiler 167 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
Cerapur Aero boiler 167 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
Cerapur Aero boiler 167 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
Cerapur Aero boiler 167 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
Cerapur Aero boiler 167 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
Cerapur Aero boiler 167 seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff
Cerapur Aero boiler 167 seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle
Cerapur Aero boiler 167 solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp
Cerapur Aero boiler 167 type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type
Cerapur Aero boiler 167 comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort
Cerapur Aero boiler 167 comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1
Cerapur Aero boiler 167 flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset
Cerapur Aero boiler 167 chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization
Cerapur Aero boiler 167 maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower
Cerapur Aero boiler 167 maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp
Cerapur Aero boiler 167 circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump
Cerapur Aero boiler 167 chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype
Cerapur Aero boiler 167 hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston
Cerapur Aero boiler 167 hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff
Cerapur Aero boiler 167 disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp
Cerapur Aero boiler 167 circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode
Cerapur Aero boiler 167 circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ
Cerapur Aero boiler 167 curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp
Cerapur Aero boiler 167 curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2
Cerapur Aero boiler 167 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
Cerapur Aero boiler 167 storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1
Cerapur Aero boiler 167 storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2
Cerapur Aero boiler 167 activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated
Cerapur Aero boiler 167 onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime
Cerapur Aero boiler 167 disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting
Cerapur Aero boiler 167 charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging
Cerapur Aero boiler 167 recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging
Cerapur Aero boiler 167 tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok
Cerapur Aero boiler 167 active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active
Cerapur Aero boiler 167 3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve
Cerapur Aero boiler 167 setpumppower set pump power uint8 (>=0<=100) % False sensor.boiler_dhw_set_pump_power sensor.boiler_dhw_setpumppower
Cerapur Aero boiler 167 mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp
Cerapur Aero boiler 167 cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp
Cerapur Aero boiler 167 starts starts uint24 (>=0<=16777213) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts
Cerapur Aero boiler 167 workm active time time (>=0<=16777213) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm
Cerapur Aero boiler 167 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower
Cerapur Aero boiler 167 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal
Cerapur Aero boiler 167 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat
Cerapur Aero boiler 167 nrgdhw energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrgdhw
Hybrid Heatpump boiler 168 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
Hybrid Heatpump boiler 168 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
Hybrid Heatpump boiler 168 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
Hybrid Heatpump boiler 168 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
Hybrid Heatpump boiler 168 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
Hybrid Heatpump boiler 168 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
Hybrid Heatpump boiler 168 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
Hybrid Heatpump boiler 168 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
Hybrid Heatpump boiler 168 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
Hybrid Heatpump boiler 168 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
Hybrid Heatpump boiler 168 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
Hybrid Heatpump boiler 168 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
Hybrid Heatpump boiler 168 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
Hybrid Heatpump boiler 168 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp
Hybrid Heatpump boiler 168 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas
Hybrid Heatpump boiler 168 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2
Hybrid Heatpump boiler 168 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr
Hybrid Heatpump boiler 168 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork
Hybrid Heatpump boiler 168 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork
Hybrid Heatpump boiler 168 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat
Hybrid Heatpump boiler 168 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower
Hybrid Heatpump boiler 168 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower
Hybrid Heatpump boiler 168 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod
Hybrid Heatpump boiler 168 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow
Hybrid Heatpump boiler 168 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock
Hybrid Heatpump boiler 168 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston
Hybrid Heatpump boiler 168 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff
Hybrid Heatpump boiler 168 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston
Hybrid Heatpump boiler 168 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff
Hybrid Heatpump boiler 168 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon
Hybrid Heatpump boiler 168 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase
Hybrid Heatpump boiler 168 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend
Hybrid Heatpump boiler 168 summertemp summer temperature uint8 (>=0<=30) C True number.boiler_summer_temperature number.boiler_summertemp
Hybrid Heatpump boiler 168 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode
Hybrid Heatpump boiler 168 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp
Hybrid Heatpump boiler 168 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
Hybrid Heatpump boiler 168 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
Hybrid Heatpump boiler 168 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
Hybrid Heatpump boiler 168 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
Hybrid Heatpump boiler 168 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
Hybrid Heatpump boiler 168 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
Hybrid Heatpump boiler 168 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
Hybrid Heatpump boiler 168 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
Hybrid Heatpump boiler 168 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
Hybrid Heatpump boiler 168 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
Hybrid Heatpump boiler 168 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
Hybrid Heatpump boiler 168 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
Hybrid Heatpump boiler 168 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
Hybrid Heatpump boiler 168 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
Hybrid Heatpump boiler 168 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
Hybrid Heatpump boiler 168 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
Hybrid Heatpump boiler 168 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
Hybrid Heatpump boiler 168 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
Hybrid Heatpump boiler 168 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
Hybrid Heatpump boiler 168 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
Hybrid Heatpump boiler 168 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
Hybrid Heatpump boiler 168 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
Hybrid Heatpump boiler 168 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
Hybrid Heatpump boiler 168 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
Hybrid Heatpump boiler 168 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
Hybrid Heatpump boiler 168 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
Hybrid Heatpump boiler 168 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
Hybrid Heatpump boiler 168 meterdhw meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
Hybrid Heatpump boiler 168 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat
Hybrid Heatpump boiler 168 gasmeterdhw gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeterdhw
Hybrid Heatpump boiler 168 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2
Hybrid Heatpump boiler 168 nrgdhw2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrgdhw2
Hybrid Heatpump boiler 168 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
Hybrid Heatpump boiler 168 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
Hybrid Heatpump boiler 168 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
Hybrid Heatpump boiler 168 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
Hybrid Heatpump boiler 168 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
Hybrid Heatpump boiler 168 seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff
Hybrid Heatpump boiler 168 seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle
Hybrid Heatpump boiler 168 solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp
Hybrid Heatpump boiler 168 type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type
Hybrid Heatpump boiler 168 comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort
Hybrid Heatpump boiler 168 comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1
Hybrid Heatpump boiler 168 flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset
Hybrid Heatpump boiler 168 chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization
Hybrid Heatpump boiler 168 maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower
Hybrid Heatpump boiler 168 maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp
Hybrid Heatpump boiler 168 circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump
Hybrid Heatpump boiler 168 chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype
Hybrid Heatpump boiler 168 hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston
Hybrid Heatpump boiler 168 hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff
Hybrid Heatpump boiler 168 disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp
Hybrid Heatpump boiler 168 circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode
Hybrid Heatpump boiler 168 circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ
Hybrid Heatpump boiler 168 curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp
Hybrid Heatpump boiler 168 curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2
Hybrid Heatpump boiler 168 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
Hybrid Heatpump boiler 168 storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1
Hybrid Heatpump boiler 168 storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2
Hybrid Heatpump boiler 168 activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated
Hybrid Heatpump boiler 168 onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime
Hybrid Heatpump boiler 168 disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting
Hybrid Heatpump boiler 168 charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging
Hybrid Heatpump boiler 168 recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging
Hybrid Heatpump boiler 168 tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok
Hybrid Heatpump boiler 168 active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active
Hybrid Heatpump boiler 168 3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve
Hybrid Heatpump boiler 168 setpumppower set pump power uint8 (>=0<=100) % False sensor.boiler_dhw_set_pump_power sensor.boiler_dhw_setpumppower
Hybrid Heatpump boiler 168 mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp
Hybrid Heatpump boiler 168 cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp
Hybrid Heatpump boiler 168 starts starts uint24 (>=0<=16777213) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts
Hybrid Heatpump boiler 168 workm active time time (>=0<=16777213) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm
Hybrid Heatpump boiler 168 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower
Hybrid Heatpump boiler 168 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal
Hybrid Heatpump boiler 168 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat
Hybrid Heatpump boiler 168 nrgdhw energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrgdhw
Logano GB212 boiler 170 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
Logano GB212 boiler 170 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
Logano GB212 boiler 170 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
Logano GB212 boiler 170 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
Logano GB212 boiler 170 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
Logano GB212 boiler 170 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
Logano GB212 boiler 170 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
Logano GB212 boiler 170 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
Logano GB212 boiler 170 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
Logano GB212 boiler 170 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
Logano GB212 boiler 170 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
Logano GB212 boiler 170 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
Logano GB212 boiler 170 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
Logano GB212 boiler 170 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp
Logano GB212 boiler 170 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas
Logano GB212 boiler 170 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2
Logano GB212 boiler 170 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr
Logano GB212 boiler 170 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork
Logano GB212 boiler 170 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork
Logano GB212 boiler 170 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat
Logano GB212 boiler 170 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower
Logano GB212 boiler 170 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower
Logano GB212 boiler 170 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod
Logano GB212 boiler 170 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow
Logano GB212 boiler 170 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock
Logano GB212 boiler 170 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston
Logano GB212 boiler 170 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff
Logano GB212 boiler 170 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston
Logano GB212 boiler 170 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff
Logano GB212 boiler 170 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon
Logano GB212 boiler 170 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase
Logano GB212 boiler 170 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend
Logano GB212 boiler 170 summertemp summer temperature uint8 (>=0<=30) C True number.boiler_summer_temperature number.boiler_summertemp
Logano GB212 boiler 170 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode
Logano GB212 boiler 170 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp
Logano GB212 boiler 170 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
Logano GB212 boiler 170 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
Logano GB212 boiler 170 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
Logano GB212 boiler 170 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
Logano GB212 boiler 170 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
Logano GB212 boiler 170 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
Logano GB212 boiler 170 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
Logano GB212 boiler 170 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
Logano GB212 boiler 170 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
Logano GB212 boiler 170 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
Logano GB212 boiler 170 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
Logano GB212 boiler 170 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
Logano GB212 boiler 170 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
Logano GB212 boiler 170 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
Logano GB212 boiler 170 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
Logano GB212 boiler 170 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
Logano GB212 boiler 170 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
Logano GB212 boiler 170 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
Logano GB212 boiler 170 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
Logano GB212 boiler 170 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
Logano GB212 boiler 170 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
Logano GB212 boiler 170 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
Logano GB212 boiler 170 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
Logano GB212 boiler 170 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
Logano GB212 boiler 170 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
Logano GB212 boiler 170 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
Logano GB212 boiler 170 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
Logano GB212 boiler 170 meterdhw meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
Logano GB212 boiler 170 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat
Logano GB212 boiler 170 gasmeterdhw gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeterdhw
Logano GB212 boiler 170 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2
Logano GB212 boiler 170 nrgdhw2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrgdhw2
Logano GB212 boiler 170 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
Logano GB212 boiler 170 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
Logano GB212 boiler 170 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
Logano GB212 boiler 170 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
Logano GB212 boiler 170 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
Logano GB212 boiler 170 seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff
Logano GB212 boiler 170 seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle
Logano GB212 boiler 170 solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp
Logano GB212 boiler 170 type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type
Logano GB212 boiler 170 comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort
Logano GB212 boiler 170 comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1
Logano GB212 boiler 170 flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset
Logano GB212 boiler 170 chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization
Logano GB212 boiler 170 maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower
Logano GB212 boiler 170 maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp
Logano GB212 boiler 170 circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump
Logano GB212 boiler 170 chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype
Logano GB212 boiler 170 hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston
Logano GB212 boiler 170 hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff
Logano GB212 boiler 170 disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp
Logano GB212 boiler 170 circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode
Logano GB212 boiler 170 circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ
Logano GB212 boiler 170 curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp
Logano GB212 boiler 170 curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2
Logano GB212 boiler 170 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
Logano GB212 boiler 170 storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1
Logano GB212 boiler 170 storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2
Logano GB212 boiler 170 activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated
Logano GB212 boiler 170 onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime
Logano GB212 boiler 170 disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting
Logano GB212 boiler 170 charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging
Logano GB212 boiler 170 recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging
Logano GB212 boiler 170 tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok
Logano GB212 boiler 170 active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active
Logano GB212 boiler 170 3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve
Logano GB212 boiler 170 setpumppower set pump power uint8 (>=0<=100) % False sensor.boiler_dhw_set_pump_power sensor.boiler_dhw_setpumppower
Logano GB212 boiler 170 mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp
Logano GB212 boiler 170 cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp
Logano GB212 boiler 170 starts starts uint24 (>=0<=16777213) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts
Logano GB212 boiler 170 workm active time time (>=0<=16777213) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm
Logano GB212 boiler 170 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower
Logano GB212 boiler 170 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal
Logano GB212 boiler 170 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat
Logano GB212 boiler 170 nrgdhw energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrgdhw
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 nrgdhw energy uint24 (>=0<=167772) kWh False sensor.boiler_dhw_energy sensor.boiler_dhw_nrgdhw
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 nrgheat energy heating uint24 (>=0<=167772) kWh False sensor.boiler_energy_heating sensor.boiler_nrgheat
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 metertotal meter total uint24 (>=0<=167772) kWh False sensor.boiler_meter_total sensor.boiler_metertotal
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 metercomp meter compressor uint24 (>=0<=167772) kWh False sensor.boiler_meter_compressor sensor.boiler_metercomp
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 metereheat meter e-heater uint24 (>=0<=167772) kWh False sensor.boiler_meter_e-heater sensor.boiler_metereheat
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 meterheat meter heating uint24 (>=0<=167772) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 meterdhw meter uint24 (>=0<=167772) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 uptimetotal heatpump total uptime time (>=0<=279620) minutes False sensor.boiler_heatpump_total_uptime sensor.boiler_uptimetotal
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 uptimecontrol total operating time heat time (>=0<=279620) minutes False sensor.boiler_total_operating_time_heat sensor.boiler_uptimecontrol
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 uptimecompheating operating time compressor heating time (>=0<=279620) minutes False sensor.boiler_operating_time_compressor_heating sensor.boiler_uptimecompheating
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 uptimecompcooling operating time compressor cooling time (>=0<=279620) minutes False sensor.boiler_operating_time_compressor_cooling sensor.boiler_uptimecompcooling
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 uptimecompdhw operating time compressor time (>=0<=279620) minutes False sensor.boiler_dhw_operating_time_compressor sensor.boiler_dhw_uptimecompdhw
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 uptimecomppool operating time compressor pool time (>=0<=279620) minutes False sensor.boiler_operating_time_compressor_pool sensor.boiler_uptimecomppool
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 totalcompstarts total compressor control starts uint24 (>=0<=16777213) False sensor.boiler_total_compressor_control_starts sensor.boiler_totalcompstarts
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 heatingstarts heating control starts uint24 (>=0<=16777213) False sensor.boiler_heating_control_starts sensor.boiler_heatingstarts
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 coolingstarts cooling control starts uint24 (>=0<=16777213) False sensor.boiler_cooling_control_starts sensor.boiler_coolingstarts
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 starts2 control starts2 uint24 (>=0<=16777213) False sensor.boiler_dhw_control_starts2 sensor.boiler_dhw_starts2
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 poolstarts pool control starts uint24 (>=0<=16777213) False sensor.boiler_pool_control_starts sensor.boiler_poolstarts
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 nrgconstotal total energy consumption uint24 (>=0<=16777213) kWh False sensor.boiler_total_energy_consumption sensor.boiler_nrgconstotal
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 nrgconscomptotal total energy consumption compressor uint24 (>=0<=16777213) kWh False sensor.boiler_total_energy_consumption_compressor sensor.boiler_nrgconscomptotal
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 nrgconscompheating energy consumption compressor heating uint24 (>=0<=16777213) kWh False sensor.boiler_energy_consumption_compressor_heating sensor.boiler_nrgconscompheating
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 nrgconscompdhw energy consumption compressor uint24 (>=0<=16777213) kWh False sensor.boiler_dhw_energy_consumption_compressor sensor.boiler_dhw_nrgconscompdhw
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 nrgconscompcooling energy consumption compressor cooling uint24 (>=0<=16777213) kWh False sensor.boiler_energy_consumption_compressor_cooling sensor.boiler_nrgconscompcooling
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 nrgconscomppool energy consumption compressor pool uint24 (>=0<=16777213) kWh False sensor.boiler_energy_consumption_compressor_pool sensor.boiler_nrgconscomppool
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 auxelecheatnrgconstotal total aux elec. heater energy consumption uint24 (>=0<=16777213) kWh False sensor.boiler_total_aux_elec._heater_energy_consumption sensor.boiler_auxelecheatnrgconstotal
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 auxelecheatnrgconsheating aux elec. heater energy consumption heating uint24 (>=0<=16777213) kWh False sensor.boiler_aux_elec._heater_energy_consumption_heating sensor.boiler_auxelecheatnrgconsheating
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 auxelecheatnrgconsdhw aux elec. heater energy consumption uint24 (>=0<=16777213) kWh False sensor.boiler_dhw_aux_elec._heater_energy_consumption sensor.boiler_dhw_auxelecheatnrgconsdhw
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 auxelecheatnrgconspool aux elec. heater energy consumption pool uint24 (>=0<=16777213) kWh False sensor.boiler_aux_elec._heater_energy_consumption_pool sensor.boiler_auxelecheatnrgconspool
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 nrgsupptotal total energy supplied uint24 (>=0<=16777213) kWh False sensor.boiler_total_energy_supplied sensor.boiler_nrgsupptotal
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 nrgsuppheating total energy supplied heating uint24 (>=0<=16777213) kWh False sensor.boiler_total_energy_supplied_heating sensor.boiler_nrgsuppheating
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 nrgsuppdhw total energy warm supplied uint24 (>=0<=16777213) kWh False sensor.boiler_dhw_total_energy_warm_supplied sensor.boiler_dhw_nrgsuppdhw
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 nrgsuppcooling total energy supplied cooling uint24 (>=0<=16777213) kWh False sensor.boiler_total_energy_supplied_cooling sensor.boiler_nrgsuppcooling
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 nrgsupppool total energy supplied pool uint24 (>=0<=16777213) kWh False sensor.boiler_total_energy_supplied_pool sensor.boiler_nrgsupppool
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 hppower compressor power output uint8 (>=0<=25) kW False sensor.boiler_compressor_power_output sensor.boiler_hppower
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 hpmaxpower compressor max power uint8 (>=0<=100) % True number.boiler_compressor_max_power number.boiler_hpmaxpower
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 hpsetdiffpress set differental pressure uint8 (>=150<=750) mbar True number.boiler_set_differental_pressure number.boiler_hpsetdiffpress
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 hpcompon hp compressor boolean False binary_sensor.boiler_hp_compressor binary_sensor.boiler_hpcompon
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 hpactivity compressor activity enum [none|heating|cooling|hot water|pool|unknown|defrost] False sensor.boiler_compressor_activity sensor.boiler_hpactivity
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 hpbrinepumpspd brine pump speed uint8 (>=0<=100) % False sensor.boiler_brine_pump_speed sensor.boiler_hpbrinepumpspd
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 hpswitchvalve switch valve boolean False binary_sensor.boiler_switch_valve binary_sensor.boiler_hpswitchvalve
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 hpcompspd compressor speed uint8 (>=0<=100) % False sensor.boiler_compressor_speed sensor.boiler_hpcompspd
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 hpcircspd circulation pump speed uint8 (>=0<=100) % False sensor.boiler_circulation_pump_speed sensor.boiler_hpcircspd
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 hpbrinein brine in/evaporator int16 (>=-3199<=3199) C False sensor.boiler_brine_in/evaporator sensor.boiler_hpbrinein
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 hpbrineout brine out/condenser int16 (>=-3199<=3199) C False sensor.boiler_brine_out/condenser sensor.boiler_hpbrineout
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 hptc0 heat carrier return (TC0) int16 (>=-3199<=3199) C False sensor.boiler_heat_carrier_return_(TC0) sensor.boiler_hptc0
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 hptc1 heat carrier forward (TC1) int16 (>=-3199<=3199) C False sensor.boiler_heat_carrier_forward_(TC1) sensor.boiler_hptc1
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 hptc3 condenser temperature (TC3) int16 (>=-3199<=3199) C False sensor.boiler_condenser_temperature_(TC3) sensor.boiler_hptc3
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 hptr1 compressor temperature (TR1) int16 (>=-3199<=3199) C False sensor.boiler_compressor_temperature_(TR1) sensor.boiler_hptr1
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 hptr3 refrigerant temperature liquid side (condenser output) (TR3) int16 (>=-3199<=3199) C False sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3) sensor.boiler_hptr3
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 hptr4 evaporator inlet temperature (TR4) int16 (>=-3199<=3199) C False sensor.boiler_evaporator_inlet_temperature_(TR4) sensor.boiler_hptr4
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 hptr5 compressor inlet temperature (TR5) int16 (>=-3199<=3199) C False sensor.boiler_compressor_inlet_temperature_(TR5) sensor.boiler_hptr5
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 hptr6 compressor outlet temperature (TR6) int16 (>=-3199<=3199) C False sensor.boiler_compressor_outlet_temperature_(TR6) sensor.boiler_hptr6
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 hptr7 refrigerant temperature gas side (condenser input) (TR7) int16 (>=-3199<=3199) C False sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7) sensor.boiler_hptr7
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 hptl2 air inlet temperature (TL2) int16 (>=-3199<=3199) C False sensor.boiler_air_inlet_temperature_(TL2) sensor.boiler_hptl2
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 hppl1 low pressure side temperature (PL1) int16 (>=-3199<=3199) C False sensor.boiler_low_pressure_side_temperature_(PL1) sensor.boiler_hppl1
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 hpph1 high pressure side temperature (PH1) int16 (>=-3199<=3199) C False sensor.boiler_high_pressure_side_temperature_(PH1) sensor.boiler_hpph1
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 hpta4 drain pan temp (TA4) int16 (>=-3199<=3199) C False sensor.boiler_drain_pan_temp_(TA4) sensor.boiler_hpta4
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 hptw1 reservoir temp (TW1) int16 (>=-3199<=3199) C False sensor.boiler_reservoir_temp_(TW1) sensor.boiler_hptw1
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 poolsettemp pool set temperature uint8 (>=0<=127) C True number.boiler_pool_set_temperature number.boiler_poolsettemp
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 hp4way 4-way valve (VR4) enum [cooling & defrost|heating & dhw] False sensor.boiler_4-way_valve_(VR4) sensor.boiler_hp4way
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 hpin1opt input 1 options string True sensor.boiler_input_1_options sensor.boiler_hpin1opt
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 hpin2opt input 2 options string True sensor.boiler_input_2_options sensor.boiler_hpin2opt
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 hpin3opt input 3 options string True sensor.boiler_input_3_options sensor.boiler_hpin3opt
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 hpin4opt input 4 options string True sensor.boiler_input_4_options sensor.boiler_hpin4opt
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 maxheatcomp heat limit compressor enum [0 kW|2 kW|3 kW|4 kW|6 kW|9 kW] True select.boiler_heat_limit_compressor select.boiler_maxheatcomp
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 maxheatheat heat limit heating enum [0 kW|2 kW|3 kW|4 kW|6 kW|9 kW] True select.boiler_heat_limit_heating select.boiler_maxheatheat
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 maxheatdhw heat limit enum [0 kW|2 kW|3 kW|4 kW|6 kW|9 kW] True select.boiler_dhw_heat_limit select.boiler_dhw_maxheatdhw
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 mandefrost manual defrost boolean True switch.boiler_manual_defrost switch.boiler_mandefrost
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 pvcooling cooling only with PV boolean True switch.boiler_cooling_only_with_PV switch.boiler_pvcooling
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 auxheateronly aux heater only boolean True switch.boiler_aux_heater_only switch.boiler_auxheateronly
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 auxheateroff disable aux heater boolean True switch.boiler_disable_aux_heater switch.boiler_auxheateroff
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 auxheaterstatus aux heater status uint8 (>=0<=100) % False sensor.boiler_aux_heater_status sensor.boiler_auxheaterstatus
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 auxheaterdelay aux heater on delay uint16 (>=10<=1000) K*min True number.boiler_aux_heater_on_delay number.boiler_auxheaterdelay
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 auxmaxlimit aux heater max limit uint8 (>=0<=10) K True number.boiler_aux_heater_max_limit number.boiler_auxmaxlimit
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 auxlimitstart aux heater limit start uint8 (>=0<=10) K True number.boiler_aux_heater_limit_start number.boiler_auxlimitstart
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 auxheatrmode aux heater mode enum [eco|comfort] True select.boiler_aux_heater_mode select.boiler_auxheatrmode
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 hphystheat on/off hyst heat uint16 (>=50<=1500) K*min True number.boiler_on/off_hyst_heat number.boiler_hphystheat
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 hphystcool on/off hyst cool uint16 (>=50<=1500) K*min True number.boiler_on/off_hyst_cool number.boiler_hphystcool
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 hphystpool on/off hyst pool uint16 (>=50<=1500) K*min True number.boiler_on/off_hyst_pool number.boiler_hphystpool
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 silentmode silent mode enum [off|auto|on] True select.boiler_silent_mode select.boiler_silentmode
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 silentfrom silent mode from uint8 (>=0<=3810) minutes True number.boiler_silent_mode_from number.boiler_silentfrom
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 silentto silent mode to uint8 (>=0<=3810) minutes True number.boiler_silent_mode_to number.boiler_silentto
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 mintempsilent min outside temp for silent mode int8 (>=-126<=126) C True number.boiler_min_outside_temp_for_silent_mode number.boiler_mintempsilent
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 tempparmode outside temp parallel mode int8 (>=-126<=126) C True number.boiler_outside_temp_parallel_mode number.boiler_tempparmode
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 auxheatmix aux heater mixing valve int8 (>=-100<=100) % False sensor.boiler_aux_heater_mixing_valve sensor.boiler_auxheatmix
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 tempdiffheat temp diff TC3/TC0 heat uint8 (>=2<=10) K True number.boiler_temp_diff_TC3/TC0_heat number.boiler_tempdiffheat
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 tempdiffcool temp diff TC3/TC0 cool uint8 (>=2<=10) K True number.boiler_temp_diff_TC3/TC0_cool number.boiler_tempdiffcool
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 vpcooling valve/pump cooling boolean True switch.boiler_valve/pump_cooling switch.boiler_vpcooling
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 heatcable heating cable boolean True switch.boiler_heating_cable switch.boiler_heatcable
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 vc0valve VC0 valve boolean True switch.boiler_VC0_valve switch.boiler_vc0valve
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 primepump primary heatpump boolean True switch.boiler_primary_heatpump switch.boiler_primepump
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 primepumpmod primary heatpump modulation uint8 (>=0<=100) % True number.boiler_primary_heatpump_modulation number.boiler_primepumpmod
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 hp3way 3-way valve boolean True switch.boiler_3-way_valve switch.boiler_hp3way
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 elheatstep1 el. heater step 1 boolean True switch.boiler_el._heater_step_1 switch.boiler_elheatstep1
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 elheatstep2 el. heater step 2 boolean True switch.boiler_el._heater_step_2 switch.boiler_elheatstep2
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 elheatstep3 el. heater step 3 boolean True switch.boiler_el._heater_step_3 switch.boiler_elheatstep3
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 hpea0 condensate reservoir heating (EA0) boolean False binary_sensor.boiler_condensate_reservoir_heating_(EA0) binary_sensor.boiler_hpea0
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 hppumpmode primary heatpump mode enum [auto|continuous] True select.boiler_primary_heatpump_mode select.boiler_hppumpmode
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 fan fan uint8 (>=20<=100) % True number.boiler_fan number.boiler_fan
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 shutdown shutdown boolean True switch.boiler_shutdown switch.boiler_shutdown
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 alternatingop alternating operation boolean True switch.boiler_dhw_alternating_operation switch.boiler_dhw_alternatingop
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 altopprioheat prioritise heating during dhw uint8 (>=20<=120) minutes True number.boiler_dhw_prioritise_heating_during_dhw number.boiler_dhw_altopprioheat
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 altoppriodhw prioritise dhw during heating uint8 (>=30<=120) minutes True number.boiler_dhw_prioritise_dhw_during_heating number.boiler_dhw_altoppriodhw
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 comfoff comfort switch off uint8 (>=15<=65) C True number.boiler_dhw_comfort_switch_off number.boiler_dhw_comfoff
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 ecooff eco switch off uint8 (>=15<=65) C True number.boiler_dhw_eco_switch_off number.boiler_dhw_ecooff
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 ecoplusoff eco+ switch off uint8 (>=48<=63) C True number.boiler_dhw_eco+_switch_off number.boiler_dhw_ecoplusoff
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 comfdiff comfort diff uint8 (>=6<=12) K True number.boiler_dhw_comfort_diff number.boiler_dhw_comfdiff
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 ecodiff eco diff uint8 (>=6<=12) K True number.boiler_dhw_eco_diff number.boiler_dhw_ecodiff
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 ecoplusdiff eco+ diff uint8 (>=6<=12) K True number.boiler_dhw_eco+_diff number.boiler_dhw_ecoplusdiff
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 comfstop comfort stop temp uint8 (>=0<=254) C True number.boiler_dhw_comfort_stop_temp number.boiler_dhw_comfstop
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 ecostop eco stop temp uint8 (>=0<=254) C True number.boiler_dhw_eco_stop_temp number.boiler_dhw_ecostop
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 ecoplusstop eco+ stop temp uint8 (>=0<=254) C True number.boiler_dhw_eco+_stop_temp number.boiler_dhw_ecoplusstop
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 hpcircpumpdhw circulation pump available during dhw boolean True switch.boiler_dhw_circulation_pump_available_during_dhw switch.boiler_dhw_hpcircpumpdhw
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 setpumppower set pump power uint8 (>=0<=100) % False sensor.boiler_dhw_set_pump_power sensor.boiler_dhw_setpumppower
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 starts starts uint24 (>=0<=16777213) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i boiler 172 workm active time time (>=0<=16777213) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm
Geo 5xx boiler 173 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
Geo 5xx boiler 173 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
Geo 5xx boiler 173 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
Geo 5xx boiler 173 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
Geo 5xx boiler 173 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
Geo 5xx boiler 173 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
Geo 5xx boiler 173 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
Geo 5xx boiler 173 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
Geo 5xx boiler 173 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
Geo 5xx boiler 173 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
Geo 5xx boiler 173 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
Geo 5xx boiler 173 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
Geo 5xx boiler 173 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
Geo 5xx boiler 173 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
Geo 5xx boiler 173 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
Geo 5xx boiler 173 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
Geo 5xx boiler 173 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
Geo 5xx boiler 173 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
Geo 5xx boiler 173 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
Geo 5xx boiler 173 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
Geo 5xx boiler 173 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
Geo 5xx boiler 173 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
Geo 5xx boiler 173 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
Geo 5xx boiler 173 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
Geo 5xx boiler 173 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
Geo 5xx boiler 173 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
Geo 5xx boiler 173 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
Geo 5xx boiler 173 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
Geo 5xx boiler 173 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
Geo 5xx boiler 173 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
Geo 5xx boiler 173 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
Geo 5xx boiler 173 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
Geo 5xx boiler 173 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
Geo 5xx boiler 173 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
Geo 5xx boiler 173 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
Geo 5xx boiler 173 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
Geo 5xx boiler 173 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
Geo 5xx boiler 173 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
Geo 5xx boiler 173 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
Geo 5xx boiler 173 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal
Geo 5xx boiler 173 nrgdhw energy uint24 (>=0<=167772) kWh False sensor.boiler_dhw_energy sensor.boiler_dhw_nrgdhw
Geo 5xx boiler 173 nrgheat energy heating uint24 (>=0<=167772) kWh False sensor.boiler_energy_heating sensor.boiler_nrgheat
Geo 5xx boiler 173 metertotal meter total uint24 (>=0<=167772) kWh False sensor.boiler_meter_total sensor.boiler_metertotal
Geo 5xx boiler 173 metercomp meter compressor uint24 (>=0<=167772) kWh False sensor.boiler_meter_compressor sensor.boiler_metercomp
Geo 5xx boiler 173 metereheat meter e-heater uint24 (>=0<=167772) kWh False sensor.boiler_meter_e-heater sensor.boiler_metereheat
Geo 5xx boiler 173 meterheat meter heating uint24 (>=0<=167772) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
Geo 5xx boiler 173 meterdhw meter uint24 (>=0<=167772) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
Geo 5xx boiler 173 uptimetotal heatpump total uptime time (>=0<=279620) minutes False sensor.boiler_heatpump_total_uptime sensor.boiler_uptimetotal
Geo 5xx boiler 173 uptimecontrol total operating time heat time (>=0<=279620) minutes False sensor.boiler_total_operating_time_heat sensor.boiler_uptimecontrol
Geo 5xx boiler 173 uptimecompheating operating time compressor heating time (>=0<=279620) minutes False sensor.boiler_operating_time_compressor_heating sensor.boiler_uptimecompheating
Geo 5xx boiler 173 uptimecompcooling operating time compressor cooling time (>=0<=279620) minutes False sensor.boiler_operating_time_compressor_cooling sensor.boiler_uptimecompcooling
Geo 5xx boiler 173 uptimecompdhw operating time compressor time (>=0<=279620) minutes False sensor.boiler_dhw_operating_time_compressor sensor.boiler_dhw_uptimecompdhw
Geo 5xx boiler 173 uptimecomppool operating time compressor pool time (>=0<=279620) minutes False sensor.boiler_operating_time_compressor_pool sensor.boiler_uptimecomppool
Geo 5xx boiler 173 totalcompstarts total compressor control starts uint24 (>=0<=16777213) False sensor.boiler_total_compressor_control_starts sensor.boiler_totalcompstarts
Geo 5xx boiler 173 heatingstarts heating control starts uint24 (>=0<=16777213) False sensor.boiler_heating_control_starts sensor.boiler_heatingstarts
Geo 5xx boiler 173 coolingstarts cooling control starts uint24 (>=0<=16777213) False sensor.boiler_cooling_control_starts sensor.boiler_coolingstarts
Geo 5xx boiler 173 starts2 control starts2 uint24 (>=0<=16777213) False sensor.boiler_dhw_control_starts2 sensor.boiler_dhw_starts2
Geo 5xx boiler 173 poolstarts pool control starts uint24 (>=0<=16777213) False sensor.boiler_pool_control_starts sensor.boiler_poolstarts
Geo 5xx boiler 173 nrgconstotal total energy consumption uint24 (>=0<=16777213) kWh False sensor.boiler_total_energy_consumption sensor.boiler_nrgconstotal
Geo 5xx boiler 173 nrgconscomptotal total energy consumption compressor uint24 (>=0<=16777213) kWh False sensor.boiler_total_energy_consumption_compressor sensor.boiler_nrgconscomptotal
Geo 5xx boiler 173 nrgconscompheating energy consumption compressor heating uint24 (>=0<=16777213) kWh False sensor.boiler_energy_consumption_compressor_heating sensor.boiler_nrgconscompheating
Geo 5xx boiler 173 nrgconscompdhw energy consumption compressor uint24 (>=0<=16777213) kWh False sensor.boiler_dhw_energy_consumption_compressor sensor.boiler_dhw_nrgconscompdhw
Geo 5xx boiler 173 nrgconscompcooling energy consumption compressor cooling uint24 (>=0<=16777213) kWh False sensor.boiler_energy_consumption_compressor_cooling sensor.boiler_nrgconscompcooling
Geo 5xx boiler 173 nrgconscomppool energy consumption compressor pool uint24 (>=0<=16777213) kWh False sensor.boiler_energy_consumption_compressor_pool sensor.boiler_nrgconscomppool
Geo 5xx boiler 173 auxelecheatnrgconstotal total aux elec. heater energy consumption uint24 (>=0<=16777213) kWh False sensor.boiler_total_aux_elec._heater_energy_consumption sensor.boiler_auxelecheatnrgconstotal
Geo 5xx boiler 173 auxelecheatnrgconsheating aux elec. heater energy consumption heating uint24 (>=0<=16777213) kWh False sensor.boiler_aux_elec._heater_energy_consumption_heating sensor.boiler_auxelecheatnrgconsheating
Geo 5xx boiler 173 auxelecheatnrgconsdhw aux elec. heater energy consumption uint24 (>=0<=16777213) kWh False sensor.boiler_dhw_aux_elec._heater_energy_consumption sensor.boiler_dhw_auxelecheatnrgconsdhw
Geo 5xx boiler 173 auxelecheatnrgconspool aux elec. heater energy consumption pool uint24 (>=0<=16777213) kWh False sensor.boiler_aux_elec._heater_energy_consumption_pool sensor.boiler_auxelecheatnrgconspool
Geo 5xx boiler 173 nrgsupptotal total energy supplied uint24 (>=0<=16777213) kWh False sensor.boiler_total_energy_supplied sensor.boiler_nrgsupptotal
Geo 5xx boiler 173 nrgsuppheating total energy supplied heating uint24 (>=0<=16777213) kWh False sensor.boiler_total_energy_supplied_heating sensor.boiler_nrgsuppheating
Geo 5xx boiler 173 nrgsuppdhw total energy warm supplied uint24 (>=0<=16777213) kWh False sensor.boiler_dhw_total_energy_warm_supplied sensor.boiler_dhw_nrgsuppdhw
Geo 5xx boiler 173 nrgsuppcooling total energy supplied cooling uint24 (>=0<=16777213) kWh False sensor.boiler_total_energy_supplied_cooling sensor.boiler_nrgsuppcooling
Geo 5xx boiler 173 nrgsupppool total energy supplied pool uint24 (>=0<=16777213) kWh False sensor.boiler_total_energy_supplied_pool sensor.boiler_nrgsupppool
Geo 5xx boiler 173 hppower compressor power output uint8 (>=0<=25) kW False sensor.boiler_compressor_power_output sensor.boiler_hppower
Geo 5xx boiler 173 hpmaxpower compressor max power uint8 (>=0<=100) % True number.boiler_compressor_max_power number.boiler_hpmaxpower
Geo 5xx boiler 173 hpsetdiffpress set differental pressure uint8 (>=150<=750) mbar True number.boiler_set_differental_pressure number.boiler_hpsetdiffpress
Geo 5xx boiler 173 hpcompon hp compressor boolean False binary_sensor.boiler_hp_compressor binary_sensor.boiler_hpcompon
Geo 5xx boiler 173 hpactivity compressor activity enum [none|heating|cooling|hot water|pool|unknown|defrost] False sensor.boiler_compressor_activity sensor.boiler_hpactivity
Geo 5xx boiler 173 hpbrinepumpspd brine pump speed uint8 (>=0<=100) % False sensor.boiler_brine_pump_speed sensor.boiler_hpbrinepumpspd
Geo 5xx boiler 173 hpswitchvalve switch valve boolean False binary_sensor.boiler_switch_valve binary_sensor.boiler_hpswitchvalve
Geo 5xx boiler 173 hpcompspd compressor speed uint8 (>=0<=100) % False sensor.boiler_compressor_speed sensor.boiler_hpcompspd
Geo 5xx boiler 173 hpcircspd circulation pump speed uint8 (>=0<=100) % False sensor.boiler_circulation_pump_speed sensor.boiler_hpcircspd
Geo 5xx boiler 173 hpbrinein brine in/evaporator int16 (>=-3199<=3199) C False sensor.boiler_brine_in/evaporator sensor.boiler_hpbrinein
Geo 5xx boiler 173 hpbrineout brine out/condenser int16 (>=-3199<=3199) C False sensor.boiler_brine_out/condenser sensor.boiler_hpbrineout
Geo 5xx boiler 173 hptc0 heat carrier return (TC0) int16 (>=-3199<=3199) C False sensor.boiler_heat_carrier_return_(TC0) sensor.boiler_hptc0
Geo 5xx boiler 173 hptc1 heat carrier forward (TC1) int16 (>=-3199<=3199) C False sensor.boiler_heat_carrier_forward_(TC1) sensor.boiler_hptc1
Geo 5xx boiler 173 hptc3 condenser temperature (TC3) int16 (>=-3199<=3199) C False sensor.boiler_condenser_temperature_(TC3) sensor.boiler_hptc3
Geo 5xx boiler 173 hptr1 compressor temperature (TR1) int16 (>=-3199<=3199) C False sensor.boiler_compressor_temperature_(TR1) sensor.boiler_hptr1
Geo 5xx boiler 173 hptr3 refrigerant temperature liquid side (condenser output) (TR3) int16 (>=-3199<=3199) C False sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3) sensor.boiler_hptr3
Geo 5xx boiler 173 hptr4 evaporator inlet temperature (TR4) int16 (>=-3199<=3199) C False sensor.boiler_evaporator_inlet_temperature_(TR4) sensor.boiler_hptr4
Geo 5xx boiler 173 hptr5 compressor inlet temperature (TR5) int16 (>=-3199<=3199) C False sensor.boiler_compressor_inlet_temperature_(TR5) sensor.boiler_hptr5
Geo 5xx boiler 173 hptr6 compressor outlet temperature (TR6) int16 (>=-3199<=3199) C False sensor.boiler_compressor_outlet_temperature_(TR6) sensor.boiler_hptr6
Geo 5xx boiler 173 hptr7 refrigerant temperature gas side (condenser input) (TR7) int16 (>=-3199<=3199) C False sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7) sensor.boiler_hptr7
Geo 5xx boiler 173 hptl2 air inlet temperature (TL2) int16 (>=-3199<=3199) C False sensor.boiler_air_inlet_temperature_(TL2) sensor.boiler_hptl2
Geo 5xx boiler 173 hppl1 low pressure side temperature (PL1) int16 (>=-3199<=3199) C False sensor.boiler_low_pressure_side_temperature_(PL1) sensor.boiler_hppl1
Geo 5xx boiler 173 hpph1 high pressure side temperature (PH1) int16 (>=-3199<=3199) C False sensor.boiler_high_pressure_side_temperature_(PH1) sensor.boiler_hpph1
Geo 5xx boiler 173 hpta4 drain pan temp (TA4) int16 (>=-3199<=3199) C False sensor.boiler_drain_pan_temp_(TA4) sensor.boiler_hpta4
Geo 5xx boiler 173 hptw1 reservoir temp (TW1) int16 (>=-3199<=3199) C False sensor.boiler_reservoir_temp_(TW1) sensor.boiler_hptw1
Geo 5xx boiler 173 poolsettemp pool set temperature uint8 (>=0<=127) C True number.boiler_pool_set_temperature number.boiler_poolsettemp
Geo 5xx boiler 173 hp4way 4-way valve (VR4) enum [cooling & defrost|heating & dhw] False sensor.boiler_4-way_valve_(VR4) sensor.boiler_hp4way
Geo 5xx boiler 173 hpin1opt input 1 options string True sensor.boiler_input_1_options sensor.boiler_hpin1opt
Geo 5xx boiler 173 hpin2opt input 2 options string True sensor.boiler_input_2_options sensor.boiler_hpin2opt
Geo 5xx boiler 173 hpin3opt input 3 options string True sensor.boiler_input_3_options sensor.boiler_hpin3opt
Geo 5xx boiler 173 hpin4opt input 4 options string True sensor.boiler_input_4_options sensor.boiler_hpin4opt
Geo 5xx boiler 173 maxheatcomp heat limit compressor enum [0 kW|2 kW|3 kW|4 kW|6 kW|9 kW] True select.boiler_heat_limit_compressor select.boiler_maxheatcomp
Geo 5xx boiler 173 maxheatheat heat limit heating enum [0 kW|2 kW|3 kW|4 kW|6 kW|9 kW] True select.boiler_heat_limit_heating select.boiler_maxheatheat
Geo 5xx boiler 173 maxheatdhw heat limit enum [0 kW|2 kW|3 kW|4 kW|6 kW|9 kW] True select.boiler_dhw_heat_limit select.boiler_dhw_maxheatdhw
Geo 5xx boiler 173 mandefrost manual defrost boolean True switch.boiler_manual_defrost switch.boiler_mandefrost
Geo 5xx boiler 173 pvcooling cooling only with PV boolean True switch.boiler_cooling_only_with_PV switch.boiler_pvcooling
Geo 5xx boiler 173 auxheateronly aux heater only boolean True switch.boiler_aux_heater_only switch.boiler_auxheateronly
Geo 5xx boiler 173 auxheateroff disable aux heater boolean True switch.boiler_disable_aux_heater switch.boiler_auxheateroff
Geo 5xx boiler 173 auxheaterstatus aux heater status uint8 (>=0<=100) % False sensor.boiler_aux_heater_status sensor.boiler_auxheaterstatus
Geo 5xx boiler 173 auxheaterdelay aux heater on delay uint16 (>=10<=1000) K*min True number.boiler_aux_heater_on_delay number.boiler_auxheaterdelay
Geo 5xx boiler 173 auxmaxlimit aux heater max limit uint8 (>=0<=10) K True number.boiler_aux_heater_max_limit number.boiler_auxmaxlimit
Geo 5xx boiler 173 auxlimitstart aux heater limit start uint8 (>=0<=10) K True number.boiler_aux_heater_limit_start number.boiler_auxlimitstart
Geo 5xx boiler 173 auxheatrmode aux heater mode enum [eco|comfort] True select.boiler_aux_heater_mode select.boiler_auxheatrmode
Geo 5xx boiler 173 hphystheat on/off hyst heat uint16 (>=50<=1500) K*min True number.boiler_on/off_hyst_heat number.boiler_hphystheat
Geo 5xx boiler 173 hphystcool on/off hyst cool uint16 (>=50<=1500) K*min True number.boiler_on/off_hyst_cool number.boiler_hphystcool
Geo 5xx boiler 173 hphystpool on/off hyst pool uint16 (>=50<=1500) K*min True number.boiler_on/off_hyst_pool number.boiler_hphystpool
Geo 5xx boiler 173 silentmode silent mode enum [off|auto|on] True select.boiler_silent_mode select.boiler_silentmode
Geo 5xx boiler 173 silentfrom silent mode from uint8 (>=0<=3810) minutes True number.boiler_silent_mode_from number.boiler_silentfrom
Geo 5xx boiler 173 silentto silent mode to uint8 (>=0<=3810) minutes True number.boiler_silent_mode_to number.boiler_silentto
Geo 5xx boiler 173 mintempsilent min outside temp for silent mode int8 (>=-126<=126) C True number.boiler_min_outside_temp_for_silent_mode number.boiler_mintempsilent
Geo 5xx boiler 173 tempparmode outside temp parallel mode int8 (>=-126<=126) C True number.boiler_outside_temp_parallel_mode number.boiler_tempparmode
Geo 5xx boiler 173 auxheatmix aux heater mixing valve int8 (>=-100<=100) % False sensor.boiler_aux_heater_mixing_valve sensor.boiler_auxheatmix
Geo 5xx boiler 173 tempdiffheat temp diff TC3/TC0 heat uint8 (>=2<=10) K True number.boiler_temp_diff_TC3/TC0_heat number.boiler_tempdiffheat
Geo 5xx boiler 173 tempdiffcool temp diff TC3/TC0 cool uint8 (>=2<=10) K True number.boiler_temp_diff_TC3/TC0_cool number.boiler_tempdiffcool
Geo 5xx boiler 173 vpcooling valve/pump cooling boolean True switch.boiler_valve/pump_cooling switch.boiler_vpcooling
Geo 5xx boiler 173 heatcable heating cable boolean True switch.boiler_heating_cable switch.boiler_heatcable
Geo 5xx boiler 173 vc0valve VC0 valve boolean True switch.boiler_VC0_valve switch.boiler_vc0valve
Geo 5xx boiler 173 primepump primary heatpump boolean True switch.boiler_primary_heatpump switch.boiler_primepump
Geo 5xx boiler 173 primepumpmod primary heatpump modulation uint8 (>=0<=100) % True number.boiler_primary_heatpump_modulation number.boiler_primepumpmod
Geo 5xx boiler 173 hp3way 3-way valve boolean True switch.boiler_3-way_valve switch.boiler_hp3way
Geo 5xx boiler 173 elheatstep1 el. heater step 1 boolean True switch.boiler_el._heater_step_1 switch.boiler_elheatstep1
Geo 5xx boiler 173 elheatstep2 el. heater step 2 boolean True switch.boiler_el._heater_step_2 switch.boiler_elheatstep2
Geo 5xx boiler 173 elheatstep3 el. heater step 3 boolean True switch.boiler_el._heater_step_3 switch.boiler_elheatstep3
Geo 5xx boiler 173 hpea0 condensate reservoir heating (EA0) boolean False binary_sensor.boiler_condensate_reservoir_heating_(EA0) binary_sensor.boiler_hpea0
Geo 5xx boiler 173 hppumpmode primary heatpump mode enum [auto|continuous] True select.boiler_primary_heatpump_mode select.boiler_hppumpmode
Geo 5xx boiler 173 fan fan uint8 (>=20<=100) % True number.boiler_fan number.boiler_fan
Geo 5xx boiler 173 shutdown shutdown boolean True switch.boiler_shutdown switch.boiler_shutdown
Geo 5xx boiler 173 alternatingop alternating operation boolean True switch.boiler_dhw_alternating_operation switch.boiler_dhw_alternatingop
Geo 5xx boiler 173 altopprioheat prioritise heating during dhw uint8 (>=20<=120) minutes True number.boiler_dhw_prioritise_heating_during_dhw number.boiler_dhw_altopprioheat
Geo 5xx boiler 173 altoppriodhw prioritise dhw during heating uint8 (>=30<=120) minutes True number.boiler_dhw_prioritise_dhw_during_heating number.boiler_dhw_altoppriodhw
Geo 5xx boiler 173 comfoff comfort switch off uint8 (>=15<=65) C True number.boiler_dhw_comfort_switch_off number.boiler_dhw_comfoff
Geo 5xx boiler 173 ecooff eco switch off uint8 (>=15<=65) C True number.boiler_dhw_eco_switch_off number.boiler_dhw_ecooff
Geo 5xx boiler 173 ecoplusoff eco+ switch off uint8 (>=48<=63) C True number.boiler_dhw_eco+_switch_off number.boiler_dhw_ecoplusoff
Geo 5xx boiler 173 comfdiff comfort diff uint8 (>=6<=12) K True number.boiler_dhw_comfort_diff number.boiler_dhw_comfdiff
Geo 5xx boiler 173 ecodiff eco diff uint8 (>=6<=12) K True number.boiler_dhw_eco_diff number.boiler_dhw_ecodiff
Geo 5xx boiler 173 ecoplusdiff eco+ diff uint8 (>=6<=12) K True number.boiler_dhw_eco+_diff number.boiler_dhw_ecoplusdiff
Geo 5xx boiler 173 comfstop comfort stop temp uint8 (>=0<=254) C True number.boiler_dhw_comfort_stop_temp number.boiler_dhw_comfstop
Geo 5xx boiler 173 ecostop eco stop temp uint8 (>=0<=254) C True number.boiler_dhw_eco_stop_temp number.boiler_dhw_ecostop
Geo 5xx boiler 173 ecoplusstop eco+ stop temp uint8 (>=0<=254) C True number.boiler_dhw_eco+_stop_temp number.boiler_dhw_ecoplusstop
Geo 5xx boiler 173 hpcircpumpdhw circulation pump available during dhw boolean True switch.boiler_dhw_circulation_pump_available_during_dhw switch.boiler_dhw_hpcircpumpdhw
Geo 5xx boiler 173 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
Geo 5xx boiler 173 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
Geo 5xx boiler 173 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
Geo 5xx boiler 173 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
Geo 5xx boiler 173 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
Geo 5xx boiler 173 seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff
Geo 5xx boiler 173 seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle
Geo 5xx boiler 173 solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp
Geo 5xx boiler 173 type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type
Geo 5xx boiler 173 comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort
Geo 5xx boiler 173 comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1
Geo 5xx boiler 173 flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset
Geo 5xx boiler 173 chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization
Geo 5xx boiler 173 maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower
Geo 5xx boiler 173 maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp
Geo 5xx boiler 173 circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump
Geo 5xx boiler 173 chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype
Geo 5xx boiler 173 hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston
Geo 5xx boiler 173 hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff
Geo 5xx boiler 173 disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp
Geo 5xx boiler 173 circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode
Geo 5xx boiler 173 circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ
Geo 5xx boiler 173 curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp
Geo 5xx boiler 173 curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2
Geo 5xx boiler 173 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
Geo 5xx boiler 173 storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1
Geo 5xx boiler 173 storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2
Geo 5xx boiler 173 activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated
Geo 5xx boiler 173 onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime
Geo 5xx boiler 173 disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting
Geo 5xx boiler 173 charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging
Geo 5xx boiler 173 recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging
Geo 5xx boiler 173 tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok
Geo 5xx boiler 173 active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active
Geo 5xx boiler 173 3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve
Geo 5xx boiler 173 setpumppower set pump power uint8 (>=0<=100) % False sensor.boiler_dhw_set_pump_power sensor.boiler_dhw_setpumppower
Geo 5xx boiler 173 mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp
Geo 5xx boiler 173 cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp
Geo 5xx boiler 173 starts starts uint24 (>=0<=16777213) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts
Geo 5xx boiler 173 workm active time time (>=0<=16777213) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 summertemp summer temperature uint8 (>=0<=30) C True number.boiler_summer_temperature number.boiler_summertemp
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 meterdhw meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 gasmeterdhw gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeterdhw
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 nrgdhw2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrgdhw2
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 setpumppower set pump power uint8 (>=0<=100) % False sensor.boiler_dhw_set_pump_power sensor.boiler_dhw_setpumppower
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 starts starts uint24 (>=0<=16777213) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 workm active time time (>=0<=16777213) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 boiler 195 nrgdhw energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrgdhw
Logamax U122/Cerapur boiler 203 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
Logamax U122/Cerapur boiler 203 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
Logamax U122/Cerapur boiler 203 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
Logamax U122/Cerapur boiler 203 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
Logamax U122/Cerapur boiler 203 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
Logamax U122/Cerapur boiler 203 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
Logamax U122/Cerapur boiler 203 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
Logamax U122/Cerapur boiler 203 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
Logamax U122/Cerapur boiler 203 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
Logamax U122/Cerapur boiler 203 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
Logamax U122/Cerapur boiler 203 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
Logamax U122/Cerapur boiler 203 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
Logamax U122/Cerapur boiler 203 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
Logamax U122/Cerapur boiler 203 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp
Logamax U122/Cerapur boiler 203 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas
Logamax U122/Cerapur boiler 203 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2
Logamax U122/Cerapur boiler 203 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr
Logamax U122/Cerapur boiler 203 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork
Logamax U122/Cerapur boiler 203 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork
Logamax U122/Cerapur boiler 203 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat
Logamax U122/Cerapur boiler 203 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower
Logamax U122/Cerapur boiler 203 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower
Logamax U122/Cerapur boiler 203 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod
Logamax U122/Cerapur boiler 203 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow
Logamax U122/Cerapur boiler 203 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock
Logamax U122/Cerapur boiler 203 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston
Logamax U122/Cerapur boiler 203 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff
Logamax U122/Cerapur boiler 203 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston
Logamax U122/Cerapur boiler 203 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff
Logamax U122/Cerapur boiler 203 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon
Logamax U122/Cerapur boiler 203 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase
Logamax U122/Cerapur boiler 203 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend
Logamax U122/Cerapur boiler 203 summertemp summer temperature uint8 (>=0<=30) C True number.boiler_summer_temperature number.boiler_summertemp
Logamax U122/Cerapur boiler 203 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode
Logamax U122/Cerapur boiler 203 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp
Logamax U122/Cerapur boiler 203 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
Logamax U122/Cerapur boiler 203 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
Logamax U122/Cerapur boiler 203 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
Logamax U122/Cerapur boiler 203 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
Logamax U122/Cerapur boiler 203 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
Logamax U122/Cerapur boiler 203 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
Logamax U122/Cerapur boiler 203 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
Logamax U122/Cerapur boiler 203 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
Logamax U122/Cerapur boiler 203 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
Logamax U122/Cerapur boiler 203 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
Logamax U122/Cerapur boiler 203 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
Logamax U122/Cerapur boiler 203 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
Logamax U122/Cerapur boiler 203 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
Logamax U122/Cerapur boiler 203 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
Logamax U122/Cerapur boiler 203 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
Logamax U122/Cerapur boiler 203 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
Logamax U122/Cerapur boiler 203 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
Logamax U122/Cerapur boiler 203 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
Logamax U122/Cerapur boiler 203 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
Logamax U122/Cerapur boiler 203 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
Logamax U122/Cerapur boiler 203 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
Logamax U122/Cerapur boiler 203 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
Logamax U122/Cerapur boiler 203 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
Logamax U122/Cerapur boiler 203 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
Logamax U122/Cerapur boiler 203 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
Logamax U122/Cerapur boiler 203 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
Logamax U122/Cerapur boiler 203 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
Logamax U122/Cerapur boiler 203 meterdhw meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
Logamax U122/Cerapur boiler 203 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat
Logamax U122/Cerapur boiler 203 gasmeterdhw gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeterdhw
Logamax U122/Cerapur boiler 203 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2
Logamax U122/Cerapur boiler 203 nrgdhw2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrgdhw2
Logamax U122/Cerapur boiler 203 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
Logamax U122/Cerapur boiler 203 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
Logamax U122/Cerapur boiler 203 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
Logamax U122/Cerapur boiler 203 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
Logamax U122/Cerapur boiler 203 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
Logamax U122/Cerapur boiler 203 seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff
Logamax U122/Cerapur boiler 203 seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle
Logamax U122/Cerapur boiler 203 solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp
Logamax U122/Cerapur boiler 203 type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type
Logamax U122/Cerapur boiler 203 comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort
Logamax U122/Cerapur boiler 203 comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1
Logamax U122/Cerapur boiler 203 flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset
Logamax U122/Cerapur boiler 203 chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization
Logamax U122/Cerapur boiler 203 maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower
Logamax U122/Cerapur boiler 203 maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp
Logamax U122/Cerapur boiler 203 circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump
Logamax U122/Cerapur boiler 203 chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype
Logamax U122/Cerapur boiler 203 hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston
Logamax U122/Cerapur boiler 203 hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff
Logamax U122/Cerapur boiler 203 disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp
Logamax U122/Cerapur boiler 203 circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode
Logamax U122/Cerapur boiler 203 circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ
Logamax U122/Cerapur boiler 203 curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp
Logamax U122/Cerapur boiler 203 curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2
Logamax U122/Cerapur boiler 203 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
Logamax U122/Cerapur boiler 203 storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1
Logamax U122/Cerapur boiler 203 storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2
Logamax U122/Cerapur boiler 203 activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated
Logamax U122/Cerapur boiler 203 onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime
Logamax U122/Cerapur boiler 203 disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting
Logamax U122/Cerapur boiler 203 charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging
Logamax U122/Cerapur boiler 203 recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging
Logamax U122/Cerapur boiler 203 tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok
Logamax U122/Cerapur boiler 203 active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active
Logamax U122/Cerapur boiler 203 3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve
Logamax U122/Cerapur boiler 203 setpumppower set pump power uint8 (>=0<=100) % False sensor.boiler_dhw_set_pump_power sensor.boiler_dhw_setpumppower
Logamax U122/Cerapur boiler 203 mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp
Logamax U122/Cerapur boiler 203 cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp
Logamax U122/Cerapur boiler 203 starts starts uint24 (>=0<=16777213) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts
Logamax U122/Cerapur boiler 203 workm active time time (>=0<=16777213) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm
Logamax U122/Cerapur boiler 203 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower
Logamax U122/Cerapur boiler 203 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal
Logamax U122/Cerapur boiler 203 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat
Logamax U122/Cerapur boiler 203 nrgdhw energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrgdhw
Ecomline Excellent boiler 206 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
Ecomline Excellent boiler 206 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
Ecomline Excellent boiler 206 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
Ecomline Excellent boiler 206 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
Ecomline Excellent boiler 206 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
Ecomline Excellent boiler 206 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
Ecomline Excellent boiler 206 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
Ecomline Excellent boiler 206 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
Ecomline Excellent boiler 206 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
Ecomline Excellent boiler 206 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
Ecomline Excellent boiler 206 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
Ecomline Excellent boiler 206 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
Ecomline Excellent boiler 206 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
Ecomline Excellent boiler 206 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp
Ecomline Excellent boiler 206 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas
Ecomline Excellent boiler 206 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2
Ecomline Excellent boiler 206 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr
Ecomline Excellent boiler 206 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork
Ecomline Excellent boiler 206 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork
Ecomline Excellent boiler 206 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat
Ecomline Excellent boiler 206 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower
Ecomline Excellent boiler 206 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower
Ecomline Excellent boiler 206 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod
Ecomline Excellent boiler 206 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow
Ecomline Excellent boiler 206 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock
Ecomline Excellent boiler 206 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston
Ecomline Excellent boiler 206 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff
Ecomline Excellent boiler 206 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston
Ecomline Excellent boiler 206 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff
Ecomline Excellent boiler 206 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon
Ecomline Excellent boiler 206 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase
Ecomline Excellent boiler 206 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend
Ecomline Excellent boiler 206 summertemp summer temperature uint8 (>=0<=30) C True number.boiler_summer_temperature number.boiler_summertemp
Ecomline Excellent boiler 206 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode
Ecomline Excellent boiler 206 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp
Ecomline Excellent boiler 206 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
Ecomline Excellent boiler 206 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
Ecomline Excellent boiler 206 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
Ecomline Excellent boiler 206 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
Ecomline Excellent boiler 206 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
Ecomline Excellent boiler 206 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
Ecomline Excellent boiler 206 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
Ecomline Excellent boiler 206 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
Ecomline Excellent boiler 206 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
Ecomline Excellent boiler 206 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
Ecomline Excellent boiler 206 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
Ecomline Excellent boiler 206 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
Ecomline Excellent boiler 206 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
Ecomline Excellent boiler 206 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
Ecomline Excellent boiler 206 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
Ecomline Excellent boiler 206 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
Ecomline Excellent boiler 206 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
Ecomline Excellent boiler 206 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
Ecomline Excellent boiler 206 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
Ecomline Excellent boiler 206 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
Ecomline Excellent boiler 206 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
Ecomline Excellent boiler 206 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
Ecomline Excellent boiler 206 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
Ecomline Excellent boiler 206 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
Ecomline Excellent boiler 206 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
Ecomline Excellent boiler 206 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
Ecomline Excellent boiler 206 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
Ecomline Excellent boiler 206 meterdhw meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
Ecomline Excellent boiler 206 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat
Ecomline Excellent boiler 206 gasmeterdhw gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeterdhw
Ecomline Excellent boiler 206 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2
Ecomline Excellent boiler 206 nrgdhw2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrgdhw2
Ecomline Excellent boiler 206 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
Ecomline Excellent boiler 206 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
Ecomline Excellent boiler 206 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
Ecomline Excellent boiler 206 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
Ecomline Excellent boiler 206 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
Ecomline Excellent boiler 206 seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff
Ecomline Excellent boiler 206 seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle
Ecomline Excellent boiler 206 solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp
Ecomline Excellent boiler 206 type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type
Ecomline Excellent boiler 206 comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort
Ecomline Excellent boiler 206 comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1
Ecomline Excellent boiler 206 flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset
Ecomline Excellent boiler 206 chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization
Ecomline Excellent boiler 206 maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower
Ecomline Excellent boiler 206 maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp
Ecomline Excellent boiler 206 circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump
Ecomline Excellent boiler 206 chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype
Ecomline Excellent boiler 206 hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston
Ecomline Excellent boiler 206 hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff
Ecomline Excellent boiler 206 disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp
Ecomline Excellent boiler 206 circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode
Ecomline Excellent boiler 206 circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ
Ecomline Excellent boiler 206 curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp
Ecomline Excellent boiler 206 curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2
Ecomline Excellent boiler 206 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
Ecomline Excellent boiler 206 storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1
Ecomline Excellent boiler 206 storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2
Ecomline Excellent boiler 206 activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated
Ecomline Excellent boiler 206 onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime
Ecomline Excellent boiler 206 disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting
Ecomline Excellent boiler 206 charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging
Ecomline Excellent boiler 206 recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging
Ecomline Excellent boiler 206 tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok
Ecomline Excellent boiler 206 active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active
Ecomline Excellent boiler 206 3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve
Ecomline Excellent boiler 206 setpumppower set pump power uint8 (>=0<=100) % False sensor.boiler_dhw_set_pump_power sensor.boiler_dhw_setpumppower
Ecomline Excellent boiler 206 mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp
Ecomline Excellent boiler 206 cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp
Ecomline Excellent boiler 206 starts starts uint24 (>=0<=16777213) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts
Ecomline Excellent boiler 206 workm active time time (>=0<=16777213) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm
Ecomline Excellent boiler 206 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower
Ecomline Excellent boiler 206 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal
Ecomline Excellent boiler 206 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat
Ecomline Excellent boiler 206 nrgdhw energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrgdhw
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 summertemp summer temperature uint8 (>=0<=30) C True number.boiler_summer_temperature number.boiler_summertemp
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 meterdhw meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 gasmeterdhw gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeterdhw
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 nrgdhw2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrgdhw2
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 setpumppower set pump power uint8 (>=0<=100) % False sensor.boiler_dhw_set_pump_power sensor.boiler_dhw_setpumppower
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 starts starts uint24 (>=0<=16777213) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 workm active time time (>=0<=16777213) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat
Logamax Plus/GB192/Condens GC9000/Greenstar ErP boiler 208 nrgdhw energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrgdhw
Cascade MC400 boiler 210 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
Cascade MC400 boiler 210 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
Cascade MC400 boiler 210 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
Cascade MC400 boiler 210 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
Cascade MC400 boiler 210 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
Cascade MC400 boiler 210 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
Cascade MC400 boiler 210 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
Cascade MC400 boiler 210 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
Cascade MC400 boiler 210 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
Cascade MC400 boiler 210 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
Cascade MC400 boiler 210 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
Cascade MC400 boiler 210 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
Cascade MC400 boiler 210 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
Cascade MC400 boiler 210 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp
Cascade MC400 boiler 210 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas
Cascade MC400 boiler 210 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2
Cascade MC400 boiler 210 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr
Cascade MC400 boiler 210 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork
Cascade MC400 boiler 210 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork
Cascade MC400 boiler 210 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat
Cascade MC400 boiler 210 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower
Cascade MC400 boiler 210 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower
Cascade MC400 boiler 210 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod
Cascade MC400 boiler 210 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow
Cascade MC400 boiler 210 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock
Cascade MC400 boiler 210 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston
Cascade MC400 boiler 210 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff
Cascade MC400 boiler 210 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston
Cascade MC400 boiler 210 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff
Cascade MC400 boiler 210 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon
Cascade MC400 boiler 210 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase
Cascade MC400 boiler 210 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend
Cascade MC400 boiler 210 summertemp summer temperature uint8 (>=0<=30) C True number.boiler_summer_temperature number.boiler_summertemp
Cascade MC400 boiler 210 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode
Cascade MC400 boiler 210 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp
Cascade MC400 boiler 210 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
Cascade MC400 boiler 210 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
Cascade MC400 boiler 210 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
Cascade MC400 boiler 210 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
Cascade MC400 boiler 210 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
Cascade MC400 boiler 210 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
Cascade MC400 boiler 210 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
Cascade MC400 boiler 210 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
Cascade MC400 boiler 210 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
Cascade MC400 boiler 210 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
Cascade MC400 boiler 210 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
Cascade MC400 boiler 210 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
Cascade MC400 boiler 210 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
Cascade MC400 boiler 210 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
Cascade MC400 boiler 210 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
Cascade MC400 boiler 210 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
Cascade MC400 boiler 210 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
Cascade MC400 boiler 210 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
Cascade MC400 boiler 210 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
Cascade MC400 boiler 210 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
Cascade MC400 boiler 210 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
Cascade MC400 boiler 210 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
Cascade MC400 boiler 210 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
Cascade MC400 boiler 210 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
Cascade MC400 boiler 210 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
Cascade MC400 boiler 210 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
Cascade MC400 boiler 210 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
Cascade MC400 boiler 210 meterdhw meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
Cascade MC400 boiler 210 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat
Cascade MC400 boiler 210 gasmeterdhw gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeterdhw
Cascade MC400 boiler 210 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2
Cascade MC400 boiler 210 nrgdhw2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrgdhw2
Cascade MC400 boiler 210 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
Cascade MC400 boiler 210 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
Cascade MC400 boiler 210 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
Cascade MC400 boiler 210 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
Cascade MC400 boiler 210 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
Cascade MC400 boiler 210 seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff
Cascade MC400 boiler 210 seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle
Cascade MC400 boiler 210 solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp
Cascade MC400 boiler 210 type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type
Cascade MC400 boiler 210 comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort
Cascade MC400 boiler 210 comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1
Cascade MC400 boiler 210 flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset
Cascade MC400 boiler 210 chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization
Cascade MC400 boiler 210 maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower
Cascade MC400 boiler 210 maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp
Cascade MC400 boiler 210 circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump
Cascade MC400 boiler 210 chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype
Cascade MC400 boiler 210 hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston
Cascade MC400 boiler 210 hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff
Cascade MC400 boiler 210 disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp
Cascade MC400 boiler 210 circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode
Cascade MC400 boiler 210 circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ
Cascade MC400 boiler 210 curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp
Cascade MC400 boiler 210 curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2
Cascade MC400 boiler 210 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
Cascade MC400 boiler 210 storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1
Cascade MC400 boiler 210 storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2
Cascade MC400 boiler 210 activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated
Cascade MC400 boiler 210 onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime
Cascade MC400 boiler 210 disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting
Cascade MC400 boiler 210 charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging
Cascade MC400 boiler 210 recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging
Cascade MC400 boiler 210 tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok
Cascade MC400 boiler 210 active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active
Cascade MC400 boiler 210 3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve
Cascade MC400 boiler 210 setpumppower set pump power uint8 (>=0<=100) % False sensor.boiler_dhw_set_pump_power sensor.boiler_dhw_setpumppower
Cascade MC400 boiler 210 mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp
Cascade MC400 boiler 210 cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp
Cascade MC400 boiler 210 starts starts uint24 (>=0<=16777213) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts
Cascade MC400 boiler 210 workm active time time (>=0<=16777213) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm
Cascade MC400 boiler 210 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower
Cascade MC400 boiler 210 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal
Cascade MC400 boiler 210 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat
Cascade MC400 boiler 210 nrgdhw energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrgdhw
EasyControl Adapter boiler 211 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
EasyControl Adapter boiler 211 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
EasyControl Adapter boiler 211 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
EasyControl Adapter boiler 211 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
EasyControl Adapter boiler 211 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
EasyControl Adapter boiler 211 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
EasyControl Adapter boiler 211 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
EasyControl Adapter boiler 211 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
EasyControl Adapter boiler 211 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
EasyControl Adapter boiler 211 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
EasyControl Adapter boiler 211 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
EasyControl Adapter boiler 211 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
EasyControl Adapter boiler 211 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
EasyControl Adapter boiler 211 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp
EasyControl Adapter boiler 211 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas
EasyControl Adapter boiler 211 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2
EasyControl Adapter boiler 211 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr
EasyControl Adapter boiler 211 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork
EasyControl Adapter boiler 211 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork
EasyControl Adapter boiler 211 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat
EasyControl Adapter boiler 211 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower
EasyControl Adapter boiler 211 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower
EasyControl Adapter boiler 211 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod
EasyControl Adapter boiler 211 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow
EasyControl Adapter boiler 211 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock
EasyControl Adapter boiler 211 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston
EasyControl Adapter boiler 211 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff
EasyControl Adapter boiler 211 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston
EasyControl Adapter boiler 211 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff
EasyControl Adapter boiler 211 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon
EasyControl Adapter boiler 211 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase
EasyControl Adapter boiler 211 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend
EasyControl Adapter boiler 211 summertemp summer temperature uint8 (>=0<=30) C True number.boiler_summer_temperature number.boiler_summertemp
EasyControl Adapter boiler 211 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode
EasyControl Adapter boiler 211 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp
EasyControl Adapter boiler 211 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
EasyControl Adapter boiler 211 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
EasyControl Adapter boiler 211 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
EasyControl Adapter boiler 211 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
EasyControl Adapter boiler 211 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
EasyControl Adapter boiler 211 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
EasyControl Adapter boiler 211 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
EasyControl Adapter boiler 211 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
EasyControl Adapter boiler 211 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
EasyControl Adapter boiler 211 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
EasyControl Adapter boiler 211 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
EasyControl Adapter boiler 211 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
EasyControl Adapter boiler 211 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
EasyControl Adapter boiler 211 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
EasyControl Adapter boiler 211 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
EasyControl Adapter boiler 211 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
EasyControl Adapter boiler 211 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
EasyControl Adapter boiler 211 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
EasyControl Adapter boiler 211 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
EasyControl Adapter boiler 211 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
EasyControl Adapter boiler 211 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
EasyControl Adapter boiler 211 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
EasyControl Adapter boiler 211 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
EasyControl Adapter boiler 211 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
EasyControl Adapter boiler 211 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
EasyControl Adapter boiler 211 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
EasyControl Adapter boiler 211 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
EasyControl Adapter boiler 211 meterdhw meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
EasyControl Adapter boiler 211 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat
EasyControl Adapter boiler 211 gasmeterdhw gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeterdhw
EasyControl Adapter boiler 211 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2
EasyControl Adapter boiler 211 nrgdhw2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrgdhw2
EasyControl Adapter boiler 211 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
EasyControl Adapter boiler 211 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
EasyControl Adapter boiler 211 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
EasyControl Adapter boiler 211 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
EasyControl Adapter boiler 211 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
EasyControl Adapter boiler 211 seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff
EasyControl Adapter boiler 211 seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle
EasyControl Adapter boiler 211 solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp
EasyControl Adapter boiler 211 type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type
EasyControl Adapter boiler 211 comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort
EasyControl Adapter boiler 211 comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1
EasyControl Adapter boiler 211 flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset
EasyControl Adapter boiler 211 chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization
EasyControl Adapter boiler 211 maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower
EasyControl Adapter boiler 211 maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp
EasyControl Adapter boiler 211 circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump
EasyControl Adapter boiler 211 chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype
EasyControl Adapter boiler 211 hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston
EasyControl Adapter boiler 211 hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff
EasyControl Adapter boiler 211 disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp
EasyControl Adapter boiler 211 circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode
EasyControl Adapter boiler 211 circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ
EasyControl Adapter boiler 211 curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp
EasyControl Adapter boiler 211 curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2
EasyControl Adapter boiler 211 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
EasyControl Adapter boiler 211 storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1
EasyControl Adapter boiler 211 storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2
EasyControl Adapter boiler 211 activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated
EasyControl Adapter boiler 211 onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime
EasyControl Adapter boiler 211 disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting
EasyControl Adapter boiler 211 charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging
EasyControl Adapter boiler 211 recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging
EasyControl Adapter boiler 211 tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok
EasyControl Adapter boiler 211 active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active
EasyControl Adapter boiler 211 3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve
EasyControl Adapter boiler 211 setpumppower set pump power uint8 (>=0<=100) % False sensor.boiler_dhw_set_pump_power sensor.boiler_dhw_setpumppower
EasyControl Adapter boiler 211 mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp
EasyControl Adapter boiler 211 cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp
EasyControl Adapter boiler 211 starts starts uint24 (>=0<=16777213) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts
EasyControl Adapter boiler 211 workm active time time (>=0<=16777213) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm
EasyControl Adapter boiler 211 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower
EasyControl Adapter boiler 211 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal
EasyControl Adapter boiler 211 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat
EasyControl Adapter boiler 211 nrgdhw energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrgdhw
Greenstar HIU/Logamax kompakt WS170 boiler 219 netflowtemp heat network flow temp uint16 (>=0<=3199) C False sensor.boiler_heat_network_flow_temp sensor.boiler_netflowtemp
Greenstar HIU/Logamax kompakt WS170 boiler 219 heatvalve heating valve uint8 (>=0<=100) % False sensor.boiler_heating_valve sensor.boiler_heatvalve
Greenstar HIU/Logamax kompakt WS170 boiler 219 dhwvalve valve uint8 (>=0<=100) % False sensor.boiler_dhw_valve sensor.boiler_dhw_dhwvalve
Greenstar HIU/Logamax kompakt WS170 boiler 219 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
Greenstar HIU/Logamax kompakt WS170 boiler 219 keepwarmtemp keep warm temperature uint8 (>=0<=254) C True number.boiler_keep_warm_temperature number.boiler_keepwarmtemp
Greenstar HIU/Logamax kompakt WS170 boiler 219 setreturntemp set temp return uint8 (>=0<=254) C True number.boiler_set_temp_return number.boiler_setreturntemp
Greenstar HIU/Logamax kompakt WS170 boiler 219 heating heating boolean False binary_sensor.boiler_heating binary_sensor.boiler_heating
Greenstar HIU/Logamax kompakt WS170 boiler 219 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
Greenstar HIU/Logamax kompakt WS170 boiler 219 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
Greenstar HIU/Logamax kompakt WS170 boiler 219 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
Greenstar HIU/Logamax kompakt WS170 boiler 219 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
Greenstar HIU/Logamax kompakt WS170 boiler 219 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
Greenstar HIU/Logamax kompakt WS170 boiler 219 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
Greenstar HIU/Logamax kompakt WS170 boiler 219 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
Greenstar HIU/Logamax kompakt WS170 boiler 219 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
Greenstar HIU/Logamax kompakt WS170 boiler 219 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
Greenstar HIU/Logamax kompakt WS170 boiler 219 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
Greenstar HIU/Logamax kompakt WS170 boiler 219 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
Greenstar HIU/Logamax kompakt WS170 boiler 219 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
Greenstar HIU/Logamax kompakt WS170 boiler 219 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
Greenstar HIU/Logamax kompakt WS170 boiler 219 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
Greenstar HIU/Logamax kompakt WS170 boiler 219 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
Greenstar HIU/Logamax kompakt WS170 boiler 219 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
Greenstar HIU/Logamax kompakt WS170 boiler 219 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
Greenstar HIU/Logamax kompakt WS170 boiler 219 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
Greenstar HIU/Logamax kompakt WS170 boiler 219 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
Greenstar HIU/Logamax kompakt WS170 boiler 219 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
Greenstar HIU/Logamax kompakt WS170 boiler 219 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
Greenstar HIU/Logamax kompakt WS170 boiler 219 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
Greenstar HIU/Logamax kompakt WS170 boiler 219 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
Greenstar HIU/Logamax kompakt WS170 boiler 219 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
Greenstar HIU/Logamax kompakt WS170 boiler 219 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
Greenstar HIU/Logamax kompakt WS170 boiler 219 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
Greenstar HIU/Logamax kompakt WS170 boiler 219 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
Greenstar HIU/Logamax kompakt WS170 boiler 219 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
Greenstar HIU/Logamax kompakt WS170 boiler 219 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
Greenstar HIU/Logamax kompakt WS170 boiler 219 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
Greenstar HIU/Logamax kompakt WS170 boiler 219 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
Greenstar HIU/Logamax kompakt WS170 boiler 219 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
Greenstar HIU/Logamax kompakt WS170 boiler 219 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
Greenstar HIU/Logamax kompakt WS170 boiler 219 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
Greenstar HIU/Logamax kompakt WS170 boiler 219 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
Greenstar HIU/Logamax kompakt WS170 boiler 219 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
Greenstar HIU/Logamax kompakt WS170 boiler 219 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
Greenstar HIU/Logamax kompakt WS170 boiler 219 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
Greenstar HIU/Logamax kompakt WS170 boiler 219 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
Greenstar HIU/Logamax kompakt WS170 boiler 219 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
Greenstar HIU/Logamax kompakt WS170 boiler 219 meterdhw meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
Greenstar HIU/Logamax kompakt WS170 boiler 219 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat
Greenstar HIU/Logamax kompakt WS170 boiler 219 gasmeterdhw gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeterdhw
Greenstar HIU/Logamax kompakt WS170 boiler 219 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2
Greenstar HIU/Logamax kompakt WS170 boiler 219 nrgdhw2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrgdhw2
Greenstar HIU/Logamax kompakt WS170 boiler 219 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
Greenstar HIU/Logamax kompakt WS170 boiler 219 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
Greenstar HIU/Logamax kompakt WS170 boiler 219 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
Greenstar HIU/Logamax kompakt WS170 boiler 219 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
Greenstar HIU/Logamax kompakt WS170 boiler 219 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
Greenstar HIU/Logamax kompakt WS170 boiler 219 seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff
Greenstar HIU/Logamax kompakt WS170 boiler 219 seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle
Greenstar HIU/Logamax kompakt WS170 boiler 219 solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp
Greenstar HIU/Logamax kompakt WS170 boiler 219 type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type
Greenstar HIU/Logamax kompakt WS170 boiler 219 comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort
Greenstar HIU/Logamax kompakt WS170 boiler 219 comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1
Greenstar HIU/Logamax kompakt WS170 boiler 219 flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset
Greenstar HIU/Logamax kompakt WS170 boiler 219 chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization
Greenstar HIU/Logamax kompakt WS170 boiler 219 maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower
Greenstar HIU/Logamax kompakt WS170 boiler 219 maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp
Greenstar HIU/Logamax kompakt WS170 boiler 219 circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump
Greenstar HIU/Logamax kompakt WS170 boiler 219 chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype
Greenstar HIU/Logamax kompakt WS170 boiler 219 hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston
Greenstar HIU/Logamax kompakt WS170 boiler 219 hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff
Greenstar HIU/Logamax kompakt WS170 boiler 219 disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp
Greenstar HIU/Logamax kompakt WS170 boiler 219 circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode
Greenstar HIU/Logamax kompakt WS170 boiler 219 circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ
Greenstar HIU/Logamax kompakt WS170 boiler 219 curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp
Greenstar HIU/Logamax kompakt WS170 boiler 219 curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2
Greenstar HIU/Logamax kompakt WS170 boiler 219 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
Greenstar HIU/Logamax kompakt WS170 boiler 219 storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1
Greenstar HIU/Logamax kompakt WS170 boiler 219 storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2
Greenstar HIU/Logamax kompakt WS170 boiler 219 activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated
Greenstar HIU/Logamax kompakt WS170 boiler 219 onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime
Greenstar HIU/Logamax kompakt WS170 boiler 219 disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting
Greenstar HIU/Logamax kompakt WS170 boiler 219 charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging
Greenstar HIU/Logamax kompakt WS170 boiler 219 recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging
Greenstar HIU/Logamax kompakt WS170 boiler 219 tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok
Greenstar HIU/Logamax kompakt WS170 boiler 219 active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active
Greenstar HIU/Logamax kompakt WS170 boiler 219 3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve
Greenstar HIU/Logamax kompakt WS170 boiler 219 setpumppower set pump power uint8 (>=0<=100) % False sensor.boiler_dhw_set_pump_power sensor.boiler_dhw_setpumppower
Greenstar HIU/Logamax kompakt WS170 boiler 219 mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp
Greenstar HIU/Logamax kompakt WS170 boiler 219 cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp
Greenstar HIU/Logamax kompakt WS170 boiler 219 starts starts uint24 (>=0<=16777213) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts
Greenstar HIU/Logamax kompakt WS170 boiler 219 workm active time time (>=0<=16777213) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm
Logamax Plus GB122/Condense 2300 boiler 234 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
Logamax Plus GB122/Condense 2300 boiler 234 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
Logamax Plus GB122/Condense 2300 boiler 234 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
Logamax Plus GB122/Condense 2300 boiler 234 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
Logamax Plus GB122/Condense 2300 boiler 234 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
Logamax Plus GB122/Condense 2300 boiler 234 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
Logamax Plus GB122/Condense 2300 boiler 234 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
Logamax Plus GB122/Condense 2300 boiler 234 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
Logamax Plus GB122/Condense 2300 boiler 234 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
Logamax Plus GB122/Condense 2300 boiler 234 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
Logamax Plus GB122/Condense 2300 boiler 234 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
Logamax Plus GB122/Condense 2300 boiler 234 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
Logamax Plus GB122/Condense 2300 boiler 234 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
Logamax Plus GB122/Condense 2300 boiler 234 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp
Logamax Plus GB122/Condense 2300 boiler 234 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas
Logamax Plus GB122/Condense 2300 boiler 234 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2
Logamax Plus GB122/Condense 2300 boiler 234 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr
Logamax Plus GB122/Condense 2300 boiler 234 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork
Logamax Plus GB122/Condense 2300 boiler 234 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork
Logamax Plus GB122/Condense 2300 boiler 234 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat
Logamax Plus GB122/Condense 2300 boiler 234 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower
Logamax Plus GB122/Condense 2300 boiler 234 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower
Logamax Plus GB122/Condense 2300 boiler 234 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod
Logamax Plus GB122/Condense 2300 boiler 234 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow
Logamax Plus GB122/Condense 2300 boiler 234 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock
Logamax Plus GB122/Condense 2300 boiler 234 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston
Logamax Plus GB122/Condense 2300 boiler 234 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff
Logamax Plus GB122/Condense 2300 boiler 234 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston
Logamax Plus GB122/Condense 2300 boiler 234 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff
Logamax Plus GB122/Condense 2300 boiler 234 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon
Logamax Plus GB122/Condense 2300 boiler 234 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase
Logamax Plus GB122/Condense 2300 boiler 234 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend
Logamax Plus GB122/Condense 2300 boiler 234 summertemp summer temperature uint8 (>=0<=30) C True number.boiler_summer_temperature number.boiler_summertemp
Logamax Plus GB122/Condense 2300 boiler 234 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode
Logamax Plus GB122/Condense 2300 boiler 234 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp
Logamax Plus GB122/Condense 2300 boiler 234 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
Logamax Plus GB122/Condense 2300 boiler 234 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
Logamax Plus GB122/Condense 2300 boiler 234 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
Logamax Plus GB122/Condense 2300 boiler 234 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
Logamax Plus GB122/Condense 2300 boiler 234 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
Logamax Plus GB122/Condense 2300 boiler 234 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
Logamax Plus GB122/Condense 2300 boiler 234 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
Logamax Plus GB122/Condense 2300 boiler 234 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
Logamax Plus GB122/Condense 2300 boiler 234 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
Logamax Plus GB122/Condense 2300 boiler 234 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
Logamax Plus GB122/Condense 2300 boiler 234 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
Logamax Plus GB122/Condense 2300 boiler 234 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
Logamax Plus GB122/Condense 2300 boiler 234 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
Logamax Plus GB122/Condense 2300 boiler 234 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
Logamax Plus GB122/Condense 2300 boiler 234 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
Logamax Plus GB122/Condense 2300 boiler 234 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
Logamax Plus GB122/Condense 2300 boiler 234 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
Logamax Plus GB122/Condense 2300 boiler 234 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
Logamax Plus GB122/Condense 2300 boiler 234 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
Logamax Plus GB122/Condense 2300 boiler 234 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
Logamax Plus GB122/Condense 2300 boiler 234 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
Logamax Plus GB122/Condense 2300 boiler 234 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
Logamax Plus GB122/Condense 2300 boiler 234 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
Logamax Plus GB122/Condense 2300 boiler 234 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
Logamax Plus GB122/Condense 2300 boiler 234 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
Logamax Plus GB122/Condense 2300 boiler 234 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
Logamax Plus GB122/Condense 2300 boiler 234 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
Logamax Plus GB122/Condense 2300 boiler 234 meterdhw meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
Logamax Plus GB122/Condense 2300 boiler 234 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat
Logamax Plus GB122/Condense 2300 boiler 234 gasmeterdhw gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeterdhw
Logamax Plus GB122/Condense 2300 boiler 234 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2
Logamax Plus GB122/Condense 2300 boiler 234 nrgdhw2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrgdhw2
Logamax Plus GB122/Condense 2300 boiler 234 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
Logamax Plus GB122/Condense 2300 boiler 234 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
Logamax Plus GB122/Condense 2300 boiler 234 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
Logamax Plus GB122/Condense 2300 boiler 234 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
Logamax Plus GB122/Condense 2300 boiler 234 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
Logamax Plus GB122/Condense 2300 boiler 234 seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff
Logamax Plus GB122/Condense 2300 boiler 234 seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle
Logamax Plus GB122/Condense 2300 boiler 234 solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp
Logamax Plus GB122/Condense 2300 boiler 234 type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type
Logamax Plus GB122/Condense 2300 boiler 234 comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort
Logamax Plus GB122/Condense 2300 boiler 234 comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1
Logamax Plus GB122/Condense 2300 boiler 234 flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset
Logamax Plus GB122/Condense 2300 boiler 234 chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization
Logamax Plus GB122/Condense 2300 boiler 234 maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower
Logamax Plus GB122/Condense 2300 boiler 234 maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp
Logamax Plus GB122/Condense 2300 boiler 234 circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump
Logamax Plus GB122/Condense 2300 boiler 234 chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype
Logamax Plus GB122/Condense 2300 boiler 234 hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston
Logamax Plus GB122/Condense 2300 boiler 234 hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff
Logamax Plus GB122/Condense 2300 boiler 234 disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp
Logamax Plus GB122/Condense 2300 boiler 234 circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode
Logamax Plus GB122/Condense 2300 boiler 234 circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ
Logamax Plus GB122/Condense 2300 boiler 234 curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp
Logamax Plus GB122/Condense 2300 boiler 234 curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2
Logamax Plus GB122/Condense 2300 boiler 234 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
Logamax Plus GB122/Condense 2300 boiler 234 storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1
Logamax Plus GB122/Condense 2300 boiler 234 storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2
Logamax Plus GB122/Condense 2300 boiler 234 activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated
Logamax Plus GB122/Condense 2300 boiler 234 onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime
Logamax Plus GB122/Condense 2300 boiler 234 disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting
Logamax Plus GB122/Condense 2300 boiler 234 charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging
Logamax Plus GB122/Condense 2300 boiler 234 recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging
Logamax Plus GB122/Condense 2300 boiler 234 tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok
Logamax Plus GB122/Condense 2300 boiler 234 active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active
Logamax Plus GB122/Condense 2300 boiler 234 3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve
Logamax Plus GB122/Condense 2300 boiler 234 setpumppower set pump power uint8 (>=0<=100) % False sensor.boiler_dhw_set_pump_power sensor.boiler_dhw_setpumppower
Logamax Plus GB122/Condense 2300 boiler 234 mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp
Logamax Plus GB122/Condense 2300 boiler 234 cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp
Logamax Plus GB122/Condense 2300 boiler 234 starts starts uint24 (>=0<=16777213) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts
Logamax Plus GB122/Condense 2300 boiler 234 workm active time time (>=0<=16777213) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm
Logamax Plus GB122/Condense 2300 boiler 234 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower
Logamax Plus GB122/Condense 2300 boiler 234 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal
Logamax Plus GB122/Condense 2300 boiler 234 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat
Logamax Plus GB122/Condense 2300 boiler 234 nrgdhw energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrgdhw
Logamatic TC100/Moduline Easy thermostat 202 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode
Logamatic TC100/Moduline Easy thermostat 202 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode
Logamatic TC100/Moduline Easy thermostat 202 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime
Logamatic TC100/Moduline Easy thermostat 202 seltemp selected room temperature int16 (>=-319<=319) C False sensor.thermostat_hc1_selected_room_temperature sensor.thermostat_hc1_seltemp
Logamatic TC100/Moduline Easy thermostat 202 currtemp current room temperature int16 (>=-319<=319) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp
Logamatic TC100/Moduline Easy thermostat 202 haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate
EasyControl/CT200 thermostat 203 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode
EasyControl/CT200 thermostat 203 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode
EasyControl/CT200 thermostat 203 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime
EasyControl/CT200 thermostat 203 seltemp selected room temperature int16 (>=-319<=319) C False sensor.thermostat_hc1_selected_room_temperature sensor.thermostat_hc1_seltemp
EasyControl/CT200 thermostat 203 currtemp current room temperature int16 (>=-319<=319) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp
EasyControl/CT200 thermostat 203 haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate
UI800/BC400 thermostat 4 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode
UI800/BC400 thermostat 4 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode
UI800/BC400 thermostat 4 datetime date/time string True sensor.thermostat_date/time sensor.thermostat_datetime
UI800/BC400 thermostat 4 intoffset internal temperature offset int8 (>=-12<=12) C True number.thermostat_internal_temperature_offset number.thermostat_intoffset
UI800/BC400 thermostat 4 floordry floor drying enum [off|start|heat|hold|cool|end] False sensor.thermostat_floor_drying sensor.thermostat_floordry
UI800/BC400 thermostat 4 dampedoutdoortemp damped outdoor temperature int16 (>=-3199<=3199) C False sensor.thermostat_damped_outdoor_temperature sensor.thermostat_dampedoutdoortemp
UI800/BC400 thermostat 4 floordrytemp floor drying temperature uint8 (>=0<=254) C False sensor.thermostat_floor_drying_temperature sensor.thermostat_floordrytemp
UI800/BC400 thermostat 4 building building type enum [light|medium|heavy] True select.thermostat_building_type select.thermostat_building
UI800/BC400 thermostat 4 minexttemp minimal external temperature int8 (>=-126<=126) C True number.thermostat_minimal_external_temperature number.thermostat_minexttemp
UI800/BC400 thermostat 4 damping damping outdoor temperature boolean True switch.thermostat_damping_outdoor_temperature switch.thermostat_damping
UI800/BC400 thermostat 4 hybridstrategy hybrid control strategy enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] True select.thermostat_hybrid_control_strategy select.thermostat_hybridstrategy
UI800/BC400 thermostat 4 switchovertemp outside switchover temperature int8 (>=-20<=20) C True number.thermostat_outside_switchover_temperature number.thermostat_switchovertemp
UI800/BC400 thermostat 4 energycostratio energy cost ratio uint8 (>=0<=20) True number.thermostat_energy_cost_ratio number.thermostat_energycostratio
UI800/BC400 thermostat 4 fossilefactor fossile energy factor uint8 (>=0<=5) True number.thermostat_fossile_energy_factor number.thermostat_fossilefactor
UI800/BC400 thermostat 4 electricfactor electric energy factor uint8 (>=0<=5) True number.thermostat_electric_energy_factor number.thermostat_electricfactor
UI800/BC400 thermostat 4 delayboiler delay boiler support uint8 (>=5<=120) minutes True number.thermostat_delay_boiler_support number.thermostat_delayboiler
UI800/BC400 thermostat 4 tempdiffboiler temp diff boiler support uint8 (>=1<=99) C True number.thermostat_temp_diff_boiler_support number.thermostat_tempdiffboiler
UI800/BC400 thermostat 4 pvenabledhw enable raise dhw boolean True switch.thermostat_enable_raise_dhw switch.thermostat_pvenabledhw
UI800/BC400 thermostat 4 pvraiseheat raise heating with PV int8 (>=0<=5) K True number.thermostat_raise_heating_with_PV number.thermostat_pvraiseheat
UI800/BC400 thermostat 4 pvlowercool lower cooling with PV int8 (>=-5<=0) K True number.thermostat_lower_cooling_with_PV number.thermostat_pvlowercool
UI800/BC400 thermostat 4 seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp
UI800/BC400 thermostat 4 currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp
UI800/BC400 thermostat 4 haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate
UI800/BC400 thermostat 4 mode mode enum [off|manual|auto] True select.thermostat_hc1_mode select.thermostat_hc1_mode
UI800/BC400 thermostat 4 modetype mode type enum [eco|comfort] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype
UI800/BC400 thermostat 4 ecotemp eco temperature uint8 (>=0<=127) C True number.thermostat_hc1_eco_temperature number.thermostat_hc1_ecotemp
UI800/BC400 thermostat 4 manualtemp manual temperature uint8 (>=0<=127) C True number.thermostat_hc1_manual_temperature number.thermostat_hc1_manualtemp
UI800/BC400 thermostat 4 comforttemp comfort temperature uint8 (>=0<=127) C True number.thermostat_hc1_comfort_temperature number.thermostat_hc1_comforttemp
UI800/BC400 thermostat 4 summertemp summer temperature uint8 (>=10<=30) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp
UI800/BC400 thermostat 4 designtemp design temperature uint8 (>=0<=254) C True number.thermostat_hc1_design_temperature number.thermostat_hc1_designtemp
UI800/BC400 thermostat 4 offsettemp offset temperature int8 (>=-126<=126) C True number.thermostat_hc1_offset_temperature number.thermostat_hc1_offsettemp
UI800/BC400 thermostat 4 minflowtemp min flow temperature uint8 (>=0<=254) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp
UI800/BC400 thermostat 4 maxflowtemp max flow temperature uint8 (>=0<=254) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp
UI800/BC400 thermostat 4 roominfluence room influence uint8 (>=0<=254) C True number.thermostat_hc1_room_influence number.thermostat_hc1_roominfluence
UI800/BC400 thermostat 4 roominflfactor room influence factor uint8 (>=0<=25) True number.thermostat_hc1_room_influence_factor number.thermostat_hc1_roominflfactor
UI800/BC400 thermostat 4 curroominfl current room influence int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_influence sensor.thermostat_hc1_curroominfl
UI800/BC400 thermostat 4 nofrostmode nofrost mode enum [room|outdoor|room outdoor] True select.thermostat_hc1_nofrost_mode select.thermostat_hc1_nofrostmode
UI800/BC400 thermostat 4 nofrosttemp nofrost temperature int8 (>=-126<=126) C True number.thermostat_hc1_nofrost_temperature number.thermostat_hc1_nofrosttemp
UI800/BC400 thermostat 4 targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp
UI800/BC400 thermostat 4 heatingtype heating type enum [off|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype
UI800/BC400 thermostat 4 summersetmode set summer mode enum [summer|auto|winter] True select.thermostat_hc1_set_summer_mode select.thermostat_hc1_summersetmode
UI800/BC400 thermostat 4 hpoperatingmode heatpump operating mode enum [off|auto|heating|cooling] True select.thermostat_hc1_heatpump_operating_mode select.thermostat_hc1_hpoperatingmode
UI800/BC400 thermostat 4 summermode summer mode enum [winter|summer] False sensor.thermostat_hc1_summer_mode sensor.thermostat_hc1_summermode
UI800/BC400 thermostat 4 hpoperatingstate heatpump operating state enum [heating|off|cooling] False sensor.thermostat_hc1_heatpump_operating_state sensor.thermostat_hc1_hpoperatingstate
UI800/BC400 thermostat 4 controlmode control mode enum [weather compensated|outside basepoint|n/a|room|power|constant] True select.thermostat_hc1_control_mode select.thermostat_hc1_controlmode
UI800/BC400 thermostat 4 program program enum [prog 1|prog 2] True select.thermostat_hc1_program select.thermostat_hc1_program
UI800/BC400 thermostat 4 tempautotemp temporary set temperature automode int8 (>=-1<=30) C True number.thermostat_hc1_temporary_set_temperature_automode number.thermostat_hc1_tempautotemp
UI800/BC400 thermostat 4 remoteseltemp temporary set temperature from remote int8 (>=-63<=63) C False sensor.thermostat_hc1_temporary_set_temperature_from_remote sensor.thermostat_hc1_remoteseltemp
UI800/BC400 thermostat 4 fastheatup fast heatup uint8 (>=0<=100) % True number.thermostat_hc1_fast_heatup number.thermostat_hc1_fastheatup
UI800/BC400 thermostat 4 switchonoptimization switch-on optimization boolean True switch.thermostat_hc1_switch-on_optimization switch.thermostat_hc1_switchonoptimization
UI800/BC400 thermostat 4 reducemode reduce mode enum [outdoor|room|reduce] True select.thermostat_hc1_reduce_mode select.thermostat_hc1_reducemode
UI800/BC400 thermostat 4 noreducetemp no reduce below temperature int8 (>=-126<=126) C True number.thermostat_hc1_no_reduce_below_temperature number.thermostat_hc1_noreducetemp
UI800/BC400 thermostat 4 reducetemp off/reduce switch temperature int8 (>=-126<=126) C True number.thermostat_hc1_off/reduce_switch_temperature number.thermostat_hc1_reducetemp
UI800/BC400 thermostat 4 dhwprio dhw priority boolean True switch.thermostat_hc1_dhw_priority switch.thermostat_hc1_dhwprio
UI800/BC400 thermostat 4 cooling cooling boolean True switch.thermostat_hc1_cooling switch.thermostat_hc1_cooling
UI800/BC400 thermostat 4 coolingon cooling boolean False binary_sensor.thermostat_hc1_cooling binary_sensor.thermostat_hc1_coolingon
UI800/BC400 thermostat 4 hpmode HP Mode enum [heating|cooling|heating&cooling] True select.thermostat_hc1_HP_Mode select.thermostat_hc1_hpmode
UI800/BC400 thermostat 4 dewoffset dew point offset uint8 (>=2<=10) K True number.thermostat_hc1_dew_point_offset number.thermostat_hc1_dewoffset
UI800/BC400 thermostat 4 roomtempdiff room temp difference uint8 (>=0<=254) K True number.thermostat_hc1_room_temp_difference number.thermostat_hc1_roomtempdiff
UI800/BC400 thermostat 4 hpminflowtemp HP min. flow temp. uint8 (>=0<=254) C True number.thermostat_hc1_HP_min._flow_temp. number.thermostat_hc1_hpminflowtemp
UI800/BC400 thermostat 4 control control device enum [RC310|RC200|RC100|RC100H|TC100] True select.thermostat_hc1_control_device select.thermostat_hc1_control
UI800/BC400 thermostat 4 remotetemp room temperature from remote int16 (>=-1<=101) C True number.thermostat_hc1_room_temperature_from_remote number.thermostat_hc1_remotetemp
UI800/BC400 thermostat 4 remotehum room humidity from remote uint8 (>=-1<=101) % True number.thermostat_hc1_room_humidity_from_remote number.thermostat_hc1_remotehum
UI800/BC400 thermostat 4 heatondelay heat-on delay uint8 (>=1<=48) hours True number.thermostat_hc1_heat-on_delay number.thermostat_hc1_heatondelay
UI800/BC400 thermostat 4 heatoffdelay heat-off delay uint8 (>=1<=48) hours True number.thermostat_hc1_heat-off_delay number.thermostat_hc1_heatoffdelay
UI800/BC400 thermostat 4 instantstart instant start uint8 (>=1<=10) K True number.thermostat_hc1_instant_start number.thermostat_hc1_instantstart
UI800/BC400 thermostat 4 boost boost mode boolean True switch.thermostat_hc1_boost_mode switch.thermostat_hc1_boost
UI800/BC400 thermostat 4 boosttime boost time uint8 (>=0<=254) hours True number.thermostat_hc1_boost_time number.thermostat_hc1_boosttime
UI800/BC400 thermostat 4 mode mode enum [off|eco+|eco|comfort|auto] True select.thermostat_dhw_mode select.thermostat_dhw_mode
UI800/BC400 thermostat 4 settemp set temperature uint8 (>=0<=254) C True number.thermostat_dhw_set_temperature number.thermostat_dhw_settemp
UI800/BC400 thermostat 4 settemplow set low temperature uint8 (>=0<=254) C True number.thermostat_dhw_set_low_temperature number.thermostat_dhw_settemplow
UI800/BC400 thermostat 4 circmode circulation pump mode enum [off|on|auto|own prog] True select.thermostat_dhw_circulation_pump_mode select.thermostat_dhw_circmode
UI800/BC400 thermostat 4 chargeduration charge duration uint8 (>=0<=3810) minutes True number.thermostat_dhw_charge_duration number.thermostat_dhw_chargeduration
UI800/BC400 thermostat 4 charge charge boolean True switch.thermostat_dhw_charge switch.thermostat_dhw_charge
UI800/BC400 thermostat 4 extra extra uint8 (>=0<=254) C False sensor.thermostat_dhw_extra sensor.thermostat_dhw_extra
UI800/BC400 thermostat 4 disinfecting disinfecting boolean True switch.thermostat_dhw_disinfecting switch.thermostat_dhw_disinfecting
UI800/BC400 thermostat 4 disinfectday disinfection day enum [mo|tu|we|th|fr|sa|su|all] True select.thermostat_dhw_disinfection_day select.thermostat_dhw_disinfectday
UI800/BC400 thermostat 4 disinfecttime disinfection time uint8 (>=0<=1431) minutes True number.thermostat_dhw_disinfection_time number.thermostat_dhw_disinfecttime
UI800/BC400 thermostat 4 dailyheating daily heating boolean True switch.thermostat_dhw_daily_heating switch.thermostat_dhw_dailyheating
UI800/BC400 thermostat 4 dailyheattime daily heating time uint8 (>=0<=1431) minutes True number.thermostat_dhw_daily_heating_time number.thermostat_dhw_dailyheattime
RC10 thermostat 65 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode
RC10 thermostat 65 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode
RC10 thermostat 65 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime
RC10 thermostat 65 minexttemp minimal external temperature int8 (>=-126<=126) C True number.thermostat_minimal_external_temperature number.thermostat_minexttemp
RC10 thermostat 65 seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp
RC10 thermostat 65 currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp
RC10 thermostat 65 haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate
RC10 thermostat 65 mode mode enum [night|day|auto] True select.thermostat_hc1_mode select.thermostat_hc1_mode
RC10 thermostat 65 modetype mode type enum [night|day] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype
RC10 thermostat 65 daytemp day temperature uint8 (>=0<=127) C True number.thermostat_hc1_day_temperature number.thermostat_hc1_daytemp
RC10 thermostat 65 nighttemp night temperature uint8 (>=0<=127) C True number.thermostat_hc1_night_temperature number.thermostat_hc1_nighttemp
RC10 thermostat 65 program program enum [family|morning|evening|am|pm|midday|singles|seniors] True select.thermostat_hc1_program select.thermostat_hc1_program
RC10 thermostat 65 minflowtemp min flow temperature uint8 (>=0<=254) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp
RC10 thermostat 65 maxflowtemp max flow temperature uint8 (>=0<=254) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp
RC10 thermostat 65 tempautotemp temporary set temperature automode uint8 (>=0<=127) C True number.thermostat_hc1_temporary_set_temperature_automode number.thermostat_hc1_tempautotemp
RC10 thermostat 65 heatingtype heating type enum [off|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype
RC10 thermostat 65 summertemp summer temperature uint8 (>=10<=30) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp
RC10 thermostat 65 summermode summer mode enum [winter|summer] False sensor.thermostat_hc1_summer_mode sensor.thermostat_hc1_summermode
RC10 thermostat 65 remotetemp room temperature from remote int16 (>=-3199<=3199) C False sensor.thermostat_hc1_room_temperature_from_remote sensor.thermostat_hc1_remotetemp
RC30 thermostat 67 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode
RC30 thermostat 67 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode
RC30 thermostat 67 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime
RC30 thermostat 67 display display enum [internal temperature|internal setpoint|external temperature|burner temperature|dhw temperature|functioning mode|time|date|smoke temperature] True select.thermostat_display select.thermostat_display
RC30 thermostat 67 language language enum [german|dutch|french|italian] False sensor.thermostat_language sensor.thermostat_language
RC30 thermostat 67 clockoffset clock offset int8 (>=-126<=126) seconds True number.thermostat_clock_offset number.thermostat_clockoffset
RC30 thermostat 67 intoffset internal temperature offset int8 (>=-12<=12) C True number.thermostat_internal_temperature_offset number.thermostat_intoffset
RC30 thermostat 67 minexttemp minimal external temperature int8 (>=-126<=126) C True number.thermostat_minimal_external_temperature number.thermostat_minexttemp
RC30 thermostat 67 inttemp1 temperature sensor 1 int16 (>=-3199<=3199) C False sensor.thermostat_temperature_sensor_1 sensor.thermostat_inttemp1
RC30 thermostat 67 inttemp2 temperature sensor 2 int16 (>=-3199<=3199) C False sensor.thermostat_temperature_sensor_2 sensor.thermostat_inttemp2
RC30 thermostat 67 damping damping outdoor temperature boolean True switch.thermostat_damping_outdoor_temperature switch.thermostat_damping
RC30 thermostat 67 dampedoutdoortemp damped outdoor temperature int8 (>=-126<=126) C False sensor.thermostat_damped_outdoor_temperature sensor.thermostat_dampedoutdoortemp
RC30 thermostat 67 building building type enum [light|medium|heavy] True select.thermostat_building_type select.thermostat_building
RC30 thermostat 67 seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp
RC30 thermostat 67 currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp
RC30 thermostat 67 haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate
RC30 thermostat 67 mode mode enum [night|day|auto] True select.thermostat_hc1_mode select.thermostat_hc1_mode
RC30 thermostat 67 modetype mode type enum [night|day] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype
RC30 thermostat 67 daytemp day temperature uint8 (>=10<=30) C True number.thermostat_hc1_day_temperature number.thermostat_hc1_daytemp
RC30 thermostat 67 nighttemp night temperature uint8 (>=10<=30) C True number.thermostat_hc1_night_temperature number.thermostat_hc1_nighttemp
RC30 thermostat 67 designtemp design temperature uint8 (>=30<=90) C True number.thermostat_hc1_design_temperature number.thermostat_hc1_designtemp
RC30 thermostat 67 offsettemp offset temperature int8 (>=-5<=5) C True number.thermostat_hc1_offset_temperature number.thermostat_hc1_offsettemp
RC30 thermostat 67 holidaytemp holiday temperature uint8 (>=5<=30) C True number.thermostat_hc1_holiday_temperature number.thermostat_hc1_holidaytemp
RC30 thermostat 67 targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp
RC30 thermostat 67 summertemp summer temperature uint8 (>=9<=25) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp
RC30 thermostat 67 summermode summer mode enum [winter|summer] False sensor.thermostat_hc1_summer_mode sensor.thermostat_hc1_summermode
RC30 thermostat 67 holidaymode holiday mode boolean False binary_sensor.thermostat_hc1_holiday_mode binary_sensor.thermostat_hc1_holidaymode
RC30 thermostat 67 nofrosttemp nofrost temperature int8 (>=-20<=10) C True number.thermostat_hc1_nofrost_temperature number.thermostat_hc1_nofrosttemp
RC30 thermostat 67 nofrostmode nofrost mode enum [off|outdoor|room] True select.thermostat_hc1_nofrost_mode select.thermostat_hc1_nofrostmode
RC30 thermostat 67 roominfluence room influence uint8 (>=0<=10) C True number.thermostat_hc1_room_influence number.thermostat_hc1_roominfluence
RC30 thermostat 67 minflowtemp min flow temperature uint8 (>=5<=70) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp
RC30 thermostat 67 maxflowtemp max flow temperature uint8 (>=30<=90) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp
RC30 thermostat 67 flowtempoffset flow temperature offset for mixer uint8 (>=0<=20) C True number.thermostat_hc1_flow_temperature_offset_for_mixer number.thermostat_hc1_flowtempoffset
RC30 thermostat 67 heatingtype heating type enum [off|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype
RC30 thermostat 67 reducemode reduce mode enum [nofrost|reduce|room|outdoor] True select.thermostat_hc1_reduce_mode select.thermostat_hc1_reducemode
RC30 thermostat 67 controlmode control mode enum [outdoor|room] True select.thermostat_hc1_control_mode select.thermostat_hc1_controlmode
RC30 thermostat 67 control control device enum [off|RC20|RC3x] True select.thermostat_hc1_control_device select.thermostat_hc1_control
RC30 thermostat 67 holidays holiday dates string True sensor.thermostat_hc1_holiday_dates sensor.thermostat_hc1_holidays
RC30 thermostat 67 vacations vacation dates string True sensor.thermostat_hc1_vacation_dates sensor.thermostat_hc1_vacations
RC30 thermostat 67 program program enum [own 1|family|morning|evening|am|pm|midday|singles|seniors|new|own 2] True select.thermostat_hc1_program select.thermostat_hc1_program
RC30 thermostat 67 pause pause time uint8 (>=0<=99) hours True number.thermostat_hc1_pause_time number.thermostat_hc1_pause
RC30 thermostat 67 party party time uint8 (>=0<=99) hours True number.thermostat_hc1_party_time number.thermostat_hc1_party
RC30 thermostat 67 tempautotemp temporary set temperature automode uint8 (>=0<=30) C True number.thermostat_hc1_temporary_set_temperature_automode number.thermostat_hc1_tempautotemp
RC30 thermostat 67 noreducetemp no reduce below temperature int8 (>=-31<=10) C True number.thermostat_hc1_no_reduce_below_temperature number.thermostat_hc1_noreducetemp
RC30 thermostat 67 reducetemp off/reduce switch temperature int8 (>=-20<=10) C True number.thermostat_hc1_off/reduce_switch_temperature number.thermostat_hc1_reducetemp
RC30 thermostat 67 vacreducetemp vacations off/reduce switch temperature int8 (>=-20<=10) C True number.thermostat_hc1_vacations_off/reduce_switch_temperature number.thermostat_hc1_vacreducetemp
RC30 thermostat 67 vacreducemode vacations reduce mode enum [nofrost|reduce|room|outdoor] True select.thermostat_hc1_vacations_reduce_mode select.thermostat_hc1_vacreducemode
RC30 thermostat 67 remotetemp room temperature from remote int16 (>=-1<=101) C True number.thermostat_hc1_room_temperature_from_remote number.thermostat_hc1_remotetemp
RC30 thermostat 67 dhwprio dhw priority boolean True switch.thermostat_hc1_dhw_priority switch.thermostat_hc1_dhwprio
RC30 thermostat 67 switchonoptimization switch-on optimization boolean True switch.thermostat_hc1_switch-on_optimization switch.thermostat_hc1_switchonoptimization
RC30 thermostat 67 switchtime1 own1 program switchtime string True sensor.thermostat_hc1_own1_program_switchtime sensor.thermostat_hc1_switchtime1
RC30 thermostat 67 switchtime2 own2 program switchtime string True sensor.thermostat_hc1_own2_program_switchtime sensor.thermostat_hc1_switchtime2
RC30 thermostat 67 mode mode enum [off|on|auto] True select.thermostat_dhw_mode select.thermostat_dhw_mode
RC30 thermostat 67 circmode circulation pump mode enum [off|on|auto] True select.thermostat_dhw_circulation_pump_mode select.thermostat_dhw_circmode
RC30 thermostat 67 progmode program enum [std prog|own prog] True select.thermostat_dhw_program select.thermostat_dhw_progmode
RC30 thermostat 67 circprog circulation program enum [std prog|own prog] True select.thermostat_dhw_circulation_program select.thermostat_dhw_circprog
RC30 thermostat 67 disinfecting disinfecting boolean True switch.thermostat_dhw_disinfecting switch.thermostat_dhw_disinfecting
RC30 thermostat 67 disinfectday disinfection day enum [mo|tu|we|th|fr|sa|su|all] True select.thermostat_dhw_disinfection_day select.thermostat_dhw_disinfectday
RC30 thermostat 67 disinfecthour disinfection hour uint8 (>=0<=23) True number.thermostat_dhw_disinfection_hour number.thermostat_dhw_disinfecthour
RC30 thermostat 67 maxtemp maximum temperature uint8 (>=0<=254) C True number.thermostat_dhw_maximum_temperature number.thermostat_dhw_maxtemp
RC30 thermostat 67 onetimekey one time key function boolean True switch.thermostat_dhw_one_time_key_function switch.thermostat_dhw_onetimekey
RC30 thermostat 67 switchtime program switchtime string True sensor.thermostat_dhw_program_switchtime sensor.thermostat_dhw_switchtime
RC30 thermostat 67 circswitchtime circulation program switchtime string True sensor.thermostat_dhw_circulation_program_switchtime sensor.thermostat_dhw_circswitchtime
RC30 thermostat 67 holidays holiday dates string True sensor.thermostat_dhw_holiday_dates sensor.thermostat_dhw_holidays
RC30 thermostat 67 vacations vacation dates string True sensor.thermostat_dhw_vacation_dates sensor.thermostat_dhw_vacations
RC20/Moduline 300 thermostat 77 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode
RC20/Moduline 300 thermostat 77 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode
RC20/Moduline 300 thermostat 77 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime
RC20/Moduline 300 thermostat 77 seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp
RC20/Moduline 300 thermostat 77 currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp
RC20/Moduline 300 thermostat 77 haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate
RC20/Moduline 300 thermostat 77 mode mode enum [off|manual|auto] True select.thermostat_hc1_mode select.thermostat_hc1_mode
RC20/Moduline 300 thermostat 77 manualtemp manual temperature uint8 (>=0<=127) C True number.thermostat_hc1_manual_temperature number.thermostat_hc1_manualtemp
RC20/Moduline 300 thermostat 77 offtemp temperature when mode is off uint8 (>=0<=127) C True number.thermostat_hc1_temperature_when_mode_is_off number.thermostat_hc1_offtemp
RC20/Moduline 300 thermostat 77 daytemp2 day temperature T2 uint8 (>=0<=127) C True number.thermostat_hc1_day_temperature_T2 number.thermostat_hc1_daytemp2
RC20/Moduline 300 thermostat 77 daytemp3 day temperature T3 uint8 (>=0<=127) C True number.thermostat_hc1_day_temperature_T3 number.thermostat_hc1_daytemp3
RC20/Moduline 300 thermostat 77 daytemp4 day temperature T4 uint8 (>=0<=127) C True number.thermostat_hc1_day_temperature_T4 number.thermostat_hc1_daytemp4
RC20/Moduline 300 thermostat 77 nighttemp night temperature T1 uint8 (>=0<=127) C True number.thermostat_hc1_night_temperature_T1 number.thermostat_hc1_nighttemp
RC20/Moduline 300 thermostat 77 switchtime program switchtime string True sensor.thermostat_hc1_program_switchtime sensor.thermostat_hc1_switchtime
Moduline 400 thermostat 78 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode
Moduline 400 thermostat 78 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode
Moduline 400 thermostat 78 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime
Moduline 400 thermostat 78 clockoffset clock offset int8 (>=-126<=126) seconds True number.thermostat_clock_offset number.thermostat_clockoffset
Moduline 400 thermostat 78 autodst automatic change daylight saving time boolean True switch.thermostat_automatic_change_daylight_saving_time switch.thermostat_autodst
Moduline 400 thermostat 78 language language enum [german|dutch] True select.thermostat_language select.thermostat_language
Moduline 400 thermostat 78 backlight key backlight boolean True switch.thermostat_key_backlight switch.thermostat_backlight
Moduline 400 thermostat 78 brightness screen brightness int8 (>=-15<=15) True number.thermostat_screen_brightness number.thermostat_brightness
Moduline 400 thermostat 78 mixingvalves mixing valves uint8 (>=0<=2) True number.thermostat_mixing_valves number.thermostat_mixingvalves
Moduline 400 thermostat 78 building building type enum [light|medium|heavy] True select.thermostat_building_type select.thermostat_building
Moduline 400 thermostat 78 heatingpid heating PID enum [fast|medium|slow] True select.thermostat_heating_PID select.thermostat_heatingpid
Moduline 400 thermostat 78 preheating preheating in the clock program boolean True switch.thermostat_preheating_in_the_clock_program switch.thermostat_preheating
Moduline 400 thermostat 78 intoffset internal temperature offset int8 (>=-12<=12) C True number.thermostat_internal_temperature_offset number.thermostat_intoffset
Moduline 400 thermostat 78 seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp
Moduline 400 thermostat 78 currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp
Moduline 400 thermostat 78 haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate
Moduline 400 thermostat 78 mode mode enum [off|manual|auto] True select.thermostat_hc1_mode select.thermostat_hc1_mode
Moduline 400 thermostat 78 holidays holiday dates string True sensor.thermostat_hc1_holiday_dates sensor.thermostat_hc1_holidays
Moduline 400 thermostat 78 vacations vacation dates string True sensor.thermostat_hc1_vacation_dates sensor.thermostat_hc1_vacations
Moduline 400 thermostat 78 program program enum [own 1|family|morning|evening|am|pm|midday|singles|seniors|new|own 2] True select.thermostat_hc1_program select.thermostat_hc1_program
Moduline 400 thermostat 78 pause pause time uint8 (>=0<=254) hours True number.thermostat_hc1_pause_time number.thermostat_hc1_pause
Moduline 400 thermostat 78 party party time uint8 (>=0<=254) hours True number.thermostat_hc1_party_time number.thermostat_hc1_party
Moduline 400 thermostat 78 switchtime1 own1 program switchtime string True sensor.thermostat_hc1_own1_program_switchtime sensor.thermostat_hc1_switchtime1
Moduline 400 thermostat 78 heatingtype heating type enum [off|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype
Moduline 400 thermostat 78 controlmode control mode enum [outdoor|room] True select.thermostat_hc1_control_mode select.thermostat_hc1_controlmode
Moduline 400 thermostat 78 holidaytemp holiday temperature uint8 (>=0<=127) C True number.thermostat_hc1_holiday_temperature number.thermostat_hc1_holidaytemp
Moduline 400 thermostat 78 nighttemp night temperature T1 uint8 (>=0<=127) C True number.thermostat_hc1_night_temperature_T1 number.thermostat_hc1_nighttemp
Moduline 400 thermostat 78 daytemp2 day temperature T2 uint8 (>=0<=127) C True number.thermostat_hc1_day_temperature_T2 number.thermostat_hc1_daytemp2
Moduline 400 thermostat 78 daytemp3 day temperature T3 uint8 (>=0<=127) C True number.thermostat_hc1_day_temperature_T3 number.thermostat_hc1_daytemp3
Moduline 400 thermostat 78 daytemp4 day temperature T4 uint8 (>=0<=127) C True number.thermostat_hc1_day_temperature_T4 number.thermostat_hc1_daytemp4
Moduline 400 thermostat 78 manualtemp manual temperature uint8 (>=0<=127) C True number.thermostat_hc1_manual_temperature number.thermostat_hc1_manualtemp
Moduline 400 thermostat 78 offtemp temperature when mode is off uint8 (>=0<=127) C True number.thermostat_hc1_temperature_when_mode_is_off number.thermostat_hc1_offtemp
Moduline 400 thermostat 78 mode mode enum [on|off|auto] True select.thermostat_dhw_mode select.thermostat_dhw_mode
Moduline 400 thermostat 78 whenmodeoff when thermostat mode off boolean True switch.thermostat_dhw_when_thermostat_mode_off switch.thermostat_dhw_whenmodeoff
Moduline 400 thermostat 78 disinfecting disinfecting boolean True switch.thermostat_dhw_disinfecting switch.thermostat_dhw_disinfecting
Moduline 400 thermostat 78 disinfectday disinfection day enum [mo|tu|we|th|fr|sa|su|all] True select.thermostat_dhw_disinfection_day select.thermostat_dhw_disinfectday
Moduline 400 thermostat 78 disinfecthour disinfection hour uint8 (>=0<=23) True number.thermostat_dhw_disinfection_hour number.thermostat_dhw_disinfecthour
Moduline 400 thermostat 78 holidays holiday dates string True sensor.thermostat_dhw_holiday_dates sensor.thermostat_dhw_holidays
Moduline 400 thermostat 78 vacations vacation dates string True sensor.thermostat_dhw_vacation_dates sensor.thermostat_dhw_vacations
RC10/Moduline 100 thermostat 79 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode
RC10/Moduline 100 thermostat 79 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode
RC10/Moduline 100 thermostat 79 intoffset internal temperature offset int8 (>=-12<=12) C True number.thermostat_internal_temperature_offset number.thermostat_intoffset
RC10/Moduline 100 thermostat 79 heatingpid heating PID enum [fast|medium|slow] True select.thermostat_heating_PID select.thermostat_heatingpid
RC10/Moduline 100 thermostat 79 backlight key backlight boolean True switch.thermostat_key_backlight switch.thermostat_backlight
RC10/Moduline 100 thermostat 79 seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp
RC10/Moduline 100 thermostat 79 currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp
RC10/Moduline 100 thermostat 79 haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate
RC10/Moduline 100 thermostat 79 mode mode enum [nofrost|night|day] True select.thermostat_hc1_mode select.thermostat_hc1_mode
RC10/Moduline 100 thermostat 79 daytemp day temperature uint8 (>=0<=127) C True number.thermostat_hc1_day_temperature number.thermostat_hc1_daytemp
RC10/Moduline 100 thermostat 79 nighttemp night temperature uint8 (>=0<=127) C True number.thermostat_hc1_night_temperature number.thermostat_hc1_nighttemp
RC10/Moduline 100 thermostat 79 reducehours duration for nighttemp uint8 (>=0<=254) hours True number.thermostat_hc1_duration_for_nighttemp number.thermostat_hc1_reducehours
RC10/Moduline 100 thermostat 79 reduceminutes remaining time for nightmode uint16 (>=0<=31999) minutes False sensor.thermostat_hc1_remaining_time_for_nightmode sensor.thermostat_hc1_reduceminutes
RC10/Moduline 100 thermostat 79 mode mode enum [on|off|auto] True select.thermostat_dhw_mode select.thermostat_dhw_mode
Moduline 200 thermostat 80 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode
Moduline 200 thermostat 80 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode
Moduline 200 thermostat 80 intoffset internal temperature offset int8 (>=-12<=12) C True number.thermostat_internal_temperature_offset number.thermostat_intoffset
Moduline 200 thermostat 80 heatingpid heating PID enum [fast|medium|slow] True select.thermostat_heating_PID select.thermostat_heatingpid
Moduline 200 thermostat 80 backlight key backlight boolean True switch.thermostat_key_backlight switch.thermostat_backlight
Moduline 200 thermostat 80 seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp
Moduline 200 thermostat 80 currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp
Moduline 200 thermostat 80 haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate
Moduline 200 thermostat 80 mode mode enum [nofrost|night|day] True select.thermostat_hc1_mode select.thermostat_hc1_mode
Moduline 200 thermostat 80 daytemp day temperature uint8 (>=0<=127) C True number.thermostat_hc1_day_temperature number.thermostat_hc1_daytemp
Moduline 200 thermostat 80 nighttemp night temperature uint8 (>=0<=127) C True number.thermostat_hc1_night_temperature number.thermostat_hc1_nighttemp
Moduline 200 thermostat 80 reducehours duration for nighttemp uint8 (>=0<=254) hours True number.thermostat_hc1_duration_for_nighttemp number.thermostat_hc1_reducehours
Moduline 200 thermostat 80 reduceminutes remaining time for nightmode uint16 (>=0<=31999) minutes False sensor.thermostat_hc1_remaining_time_for_nightmode sensor.thermostat_hc1_reduceminutes
Moduline 200 thermostat 80 mode mode enum [on|off|auto] True select.thermostat_dhw_mode select.thermostat_dhw_mode
RC35 thermostat 86 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode
RC35 thermostat 86 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode
RC35 thermostat 86 datetime date/time string True sensor.thermostat_date/time sensor.thermostat_datetime
RC35 thermostat 86 intoffset internal temperature offset int8 (>=-5<=5) C True number.thermostat_internal_temperature_offset number.thermostat_intoffset
RC35 thermostat 86 minexttemp minimal external temperature int8 (>=-30<=0) C True number.thermostat_minimal_external_temperature number.thermostat_minexttemp
RC35 thermostat 86 inttemp1 temperature sensor 1 int16 (>=-3199<=3199) C False sensor.thermostat_temperature_sensor_1 sensor.thermostat_inttemp1
RC35 thermostat 86 inttemp2 temperature sensor 2 int16 (>=-3199<=3199) C False sensor.thermostat_temperature_sensor_2 sensor.thermostat_inttemp2
RC35 thermostat 86 damping damping outdoor temperature boolean True switch.thermostat_damping_outdoor_temperature switch.thermostat_damping
RC35 thermostat 86 dampedoutdoortemp damped outdoor temperature int8 (>=-126<=126) C False sensor.thermostat_damped_outdoor_temperature sensor.thermostat_dampedoutdoortemp
RC35 thermostat 86 building building type enum [light|medium|heavy] True select.thermostat_building_type select.thermostat_building
RC35 thermostat 86 seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp
RC35 thermostat 86 currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp
RC35 thermostat 86 haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate
RC35 thermostat 86 mode mode enum [night|day|auto] True select.thermostat_hc1_mode select.thermostat_hc1_mode
RC35 thermostat 86 modetype mode type enum [night|day] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype
RC35 thermostat 86 daytemp day temperature uint8 (>=10<=30) C True number.thermostat_hc1_day_temperature number.thermostat_hc1_daytemp
RC35 thermostat 86 nighttemp night temperature uint8 (>=10<=30) C True number.thermostat_hc1_night_temperature number.thermostat_hc1_nighttemp
RC35 thermostat 86 designtemp design temperature uint8 (>=30<=90) C True number.thermostat_hc1_design_temperature number.thermostat_hc1_designtemp
RC35 thermostat 86 offsettemp offset temperature int8 (>=-5<=5) C True number.thermostat_hc1_offset_temperature number.thermostat_hc1_offsettemp
RC35 thermostat 86 holidaytemp holiday temperature uint8 (>=5<=30) C True number.thermostat_hc1_holiday_temperature number.thermostat_hc1_holidaytemp
RC35 thermostat 86 targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp
RC35 thermostat 86 summertemp summer temperature uint8 (>=9<=25) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp
RC35 thermostat 86 summermode summer mode enum [winter|summer] False sensor.thermostat_hc1_summer_mode sensor.thermostat_hc1_summermode
RC35 thermostat 86 holidaymode holiday mode boolean False binary_sensor.thermostat_hc1_holiday_mode binary_sensor.thermostat_hc1_holidaymode
RC35 thermostat 86 nofrosttemp nofrost temperature int8 (>=-20<=10) C True number.thermostat_hc1_nofrost_temperature number.thermostat_hc1_nofrosttemp
RC35 thermostat 86 nofrostmode nofrost mode enum [off|outdoor|room] True select.thermostat_hc1_nofrost_mode select.thermostat_hc1_nofrostmode
RC35 thermostat 86 roominfluence room influence uint8 (>=0<=10) C True number.thermostat_hc1_room_influence number.thermostat_hc1_roominfluence
RC35 thermostat 86 minflowtemp min flow temperature uint8 (>=5<=70) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp
RC35 thermostat 86 maxflowtemp max flow temperature uint8 (>=30<=90) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp
RC35 thermostat 86 flowtempoffset flow temperature offset for mixer uint8 (>=0<=20) C True number.thermostat_hc1_flow_temperature_offset_for_mixer number.thermostat_hc1_flowtempoffset
RC35 thermostat 86 heatingtype heating type enum [off|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype
RC35 thermostat 86 reducemode reduce mode enum [nofrost|reduce|room|outdoor] True select.thermostat_hc1_reduce_mode select.thermostat_hc1_reducemode
RC35 thermostat 86 controlmode control mode enum [outdoor|room] True select.thermostat_hc1_control_mode select.thermostat_hc1_controlmode
RC35 thermostat 86 control control device enum [off|RC20|RC3x] True select.thermostat_hc1_control_device select.thermostat_hc1_control
RC35 thermostat 86 holidays holiday dates string True sensor.thermostat_hc1_holiday_dates sensor.thermostat_hc1_holidays
RC35 thermostat 86 vacations vacation dates string True sensor.thermostat_hc1_vacation_dates sensor.thermostat_hc1_vacations
RC35 thermostat 86 program program enum [own 1|family|morning|evening|am|pm|midday|singles|seniors|new|own 2] True select.thermostat_hc1_program select.thermostat_hc1_program
RC35 thermostat 86 pause pause time uint8 (>=0<=99) hours True number.thermostat_hc1_pause_time number.thermostat_hc1_pause
RC35 thermostat 86 party party time uint8 (>=0<=99) hours True number.thermostat_hc1_party_time number.thermostat_hc1_party
RC35 thermostat 86 tempautotemp temporary set temperature automode uint8 (>=0<=30) C True number.thermostat_hc1_temporary_set_temperature_automode number.thermostat_hc1_tempautotemp
RC35 thermostat 86 noreducetemp no reduce below temperature int8 (>=-31<=10) C True number.thermostat_hc1_no_reduce_below_temperature number.thermostat_hc1_noreducetemp
RC35 thermostat 86 reducetemp off/reduce switch temperature int8 (>=-20<=10) C True number.thermostat_hc1_off/reduce_switch_temperature number.thermostat_hc1_reducetemp
RC35 thermostat 86 vacreducetemp vacations off/reduce switch temperature int8 (>=-20<=10) C True number.thermostat_hc1_vacations_off/reduce_switch_temperature number.thermostat_hc1_vacreducetemp
RC35 thermostat 86 vacreducemode vacations reduce mode enum [nofrost|reduce|room|outdoor] True select.thermostat_hc1_vacations_reduce_mode select.thermostat_hc1_vacreducemode
RC35 thermostat 86 remotetemp room temperature from remote int16 (>=-1<=101) C True number.thermostat_hc1_room_temperature_from_remote number.thermostat_hc1_remotetemp
RC35 thermostat 86 dhwprio dhw priority boolean True switch.thermostat_hc1_dhw_priority switch.thermostat_hc1_dhwprio
RC35 thermostat 86 switchonoptimization switch-on optimization boolean True switch.thermostat_hc1_switch-on_optimization switch.thermostat_hc1_switchonoptimization
RC35 thermostat 86 switchtime1 own1 program switchtime string True sensor.thermostat_hc1_own1_program_switchtime sensor.thermostat_hc1_switchtime1
RC35 thermostat 86 switchtime2 own2 program switchtime string True sensor.thermostat_hc1_own2_program_switchtime sensor.thermostat_hc1_switchtime2
RC35 thermostat 86 mode mode enum [off|on|auto] True select.thermostat_dhw_mode select.thermostat_dhw_mode
RC35 thermostat 86 circmode circulation pump mode enum [off|on|auto] True select.thermostat_dhw_circulation_pump_mode select.thermostat_dhw_circmode
RC35 thermostat 86 progmode program enum [std prog|own prog] True select.thermostat_dhw_program select.thermostat_dhw_progmode
RC35 thermostat 86 circprog circulation program enum [std prog|own prog] True select.thermostat_dhw_circulation_program select.thermostat_dhw_circprog
RC35 thermostat 86 disinfecting disinfecting boolean True switch.thermostat_dhw_disinfecting switch.thermostat_dhw_disinfecting
RC35 thermostat 86 disinfectday disinfection day enum [mo|tu|we|th|fr|sa|su|all] True select.thermostat_dhw_disinfection_day select.thermostat_dhw_disinfectday
RC35 thermostat 86 disinfecthour disinfection hour uint8 (>=0<=23) True number.thermostat_dhw_disinfection_hour number.thermostat_dhw_disinfecthour
RC35 thermostat 86 maxtemp maximum temperature uint8 (>=60<=80) C True number.thermostat_dhw_maximum_temperature number.thermostat_dhw_maxtemp
RC35 thermostat 86 onetimekey one time key function boolean True switch.thermostat_dhw_one_time_key_function switch.thermostat_dhw_onetimekey
RC35 thermostat 86 switchtime program switchtime string True sensor.thermostat_dhw_program_switchtime sensor.thermostat_dhw_switchtime
RC35 thermostat 86 circswitchtime circulation program switchtime string True sensor.thermostat_dhw_circulation_program_switchtime sensor.thermostat_dhw_circswitchtime
RC35 thermostat 86 holidays holiday dates string True sensor.thermostat_dhw_holiday_dates sensor.thermostat_dhw_holidays
RC35 thermostat 86 vacations vacation dates string True sensor.thermostat_dhw_vacation_dates sensor.thermostat_dhw_vacations
RC10/Moduline 100 thermostat 90 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode
RC10/Moduline 100 thermostat 90 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode
RC10/Moduline 100 thermostat 90 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime
RC10/Moduline 100 thermostat 90 minexttemp minimal external temperature int8 (>=-126<=126) C True number.thermostat_minimal_external_temperature number.thermostat_minexttemp
RC10/Moduline 100 thermostat 90 seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp
RC10/Moduline 100 thermostat 90 currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp
RC10/Moduline 100 thermostat 90 haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate
RC10/Moduline 100 thermostat 90 mode mode enum [night|day|auto] True select.thermostat_hc1_mode select.thermostat_hc1_mode
RC10/Moduline 100 thermostat 90 modetype mode type enum [night|day] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype
RC10/Moduline 100 thermostat 90 daytemp day temperature uint8 (>=0<=127) C True number.thermostat_hc1_day_temperature number.thermostat_hc1_daytemp
RC10/Moduline 100 thermostat 90 nighttemp night temperature uint8 (>=0<=127) C True number.thermostat_hc1_night_temperature number.thermostat_hc1_nighttemp
RC10/Moduline 100 thermostat 90 program program enum [family|morning|evening|am|pm|midday|singles|seniors] True select.thermostat_hc1_program select.thermostat_hc1_program
RC10/Moduline 100 thermostat 90 minflowtemp min flow temperature uint8 (>=0<=254) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp
RC10/Moduline 100 thermostat 90 maxflowtemp max flow temperature uint8 (>=0<=254) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp
RC10/Moduline 100 thermostat 90 tempautotemp temporary set temperature automode uint8 (>=0<=127) C True number.thermostat_hc1_temporary_set_temperature_automode number.thermostat_hc1_tempautotemp
RC10/Moduline 100 thermostat 90 heatingtype heating type enum [off|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype
RC10/Moduline 100 thermostat 90 summertemp summer temperature uint8 (>=10<=30) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp
RC10/Moduline 100 thermostat 90 summermode summer mode enum [winter|summer] False sensor.thermostat_hc1_summer_mode sensor.thermostat_hc1_summermode
RC10/Moduline 100 thermostat 90 remotetemp room temperature from remote int16 (>=-3199<=3199) C False sensor.thermostat_hc1_room_temperature_from_remote sensor.thermostat_hc1_remotetemp
RC20RF thermostat 93 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode
RC20RF thermostat 93 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode
RC20RF thermostat 93 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime
RC20RF thermostat 93 seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp
RC20RF thermostat 93 currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp
RC20RF thermostat 93 haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate
RC20RF thermostat 93 mode mode enum [off|manual|auto] True select.thermostat_hc1_mode select.thermostat_hc1_mode
RC20RF thermostat 93 manualtemp manual temperature uint8 (>=0<=127) C True number.thermostat_hc1_manual_temperature number.thermostat_hc1_manualtemp
RC20RF thermostat 93 offtemp temperature when mode is off uint8 (>=0<=127) C True number.thermostat_hc1_temperature_when_mode_is_off number.thermostat_hc1_offtemp
RC20RF thermostat 93 daytemp2 day temperature T2 uint8 (>=0<=127) C True number.thermostat_hc1_day_temperature_T2 number.thermostat_hc1_daytemp2
RC20RF thermostat 93 daytemp3 day temperature T3 uint8 (>=0<=127) C True number.thermostat_hc1_day_temperature_T3 number.thermostat_hc1_daytemp3
RC20RF thermostat 93 daytemp4 day temperature T4 uint8 (>=0<=127) C True number.thermostat_hc1_day_temperature_T4 number.thermostat_hc1_daytemp4
RC20RF thermostat 93 nighttemp night temperature T1 uint8 (>=0<=127) C True number.thermostat_hc1_night_temperature_T1 number.thermostat_hc1_nighttemp
RC20RF thermostat 93 switchtime program switchtime string True sensor.thermostat_hc1_program_switchtime sensor.thermostat_hc1_switchtime
RFM20 Remote thermostat 94 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode
RFM20 Remote thermostat 94 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode
RFM20 Remote thermostat 94 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime
RFM20 Remote thermostat 94 seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp
RFM20 Remote thermostat 94 currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp
RFM20 Remote thermostat 94 haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate
RC25 thermostat 151 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode
RC25 thermostat 151 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode
RC25 thermostat 151 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime
RC25 thermostat 151 minexttemp minimal external temperature int8 (>=-126<=126) C True number.thermostat_minimal_external_temperature number.thermostat_minexttemp
RC25 thermostat 151 seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp
RC25 thermostat 151 currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp
RC25 thermostat 151 haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate
RC25 thermostat 151 mode mode enum [night|day|auto] True select.thermostat_hc1_mode select.thermostat_hc1_mode
RC25 thermostat 151 modetype mode type enum [night|day] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype
RC25 thermostat 151 daytemp day temperature uint8 (>=0<=127) C True number.thermostat_hc1_day_temperature number.thermostat_hc1_daytemp
RC25 thermostat 151 nighttemp night temperature uint8 (>=0<=127) C True number.thermostat_hc1_night_temperature number.thermostat_hc1_nighttemp
RC25 thermostat 151 program program enum [family|morning|evening|am|pm|midday|singles|seniors] True select.thermostat_hc1_program select.thermostat_hc1_program
RC25 thermostat 151 minflowtemp min flow temperature uint8 (>=0<=254) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp
RC25 thermostat 151 maxflowtemp max flow temperature uint8 (>=0<=254) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp
RC25 thermostat 151 tempautotemp temporary set temperature automode uint8 (>=0<=127) C True number.thermostat_hc1_temporary_set_temperature_automode number.thermostat_hc1_tempautotemp
RC25 thermostat 151 heatingtype heating type enum [off|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype
RC25 thermostat 151 summertemp summer temperature uint8 (>=9<=25) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp
RC25 thermostat 151 summermode summer mode enum [winter|summer] False sensor.thermostat_hc1_summer_mode sensor.thermostat_hc1_summermode
RC200/CW100 thermostat 157 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode
RC200/CW100 thermostat 157 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode
RC200/CW100 thermostat 157 datetime date/time string True sensor.thermostat_date/time sensor.thermostat_datetime
RC200/CW100 thermostat 157 intoffset internal temperature offset int8 (>=-12<=12) C True number.thermostat_internal_temperature_offset number.thermostat_intoffset
RC200/CW100 thermostat 157 floordry floor drying enum [off|start|heat|hold|cool|end] False sensor.thermostat_floor_drying sensor.thermostat_floordry
RC200/CW100 thermostat 157 dampedoutdoortemp damped outdoor temperature int16 (>=-3199<=3199) C False sensor.thermostat_damped_outdoor_temperature sensor.thermostat_dampedoutdoortemp
RC200/CW100 thermostat 157 floordrytemp floor drying temperature uint8 (>=0<=254) C False sensor.thermostat_floor_drying_temperature sensor.thermostat_floordrytemp
RC200/CW100 thermostat 157 building building type enum [light|medium|heavy] True select.thermostat_building_type select.thermostat_building
RC200/CW100 thermostat 157 minexttemp minimal external temperature int8 (>=-126<=126) C True number.thermostat_minimal_external_temperature number.thermostat_minexttemp
RC200/CW100 thermostat 157 damping damping outdoor temperature boolean True switch.thermostat_damping_outdoor_temperature switch.thermostat_damping
RC200/CW100 thermostat 157 hybridstrategy hybrid control strategy enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] True select.thermostat_hybrid_control_strategy select.thermostat_hybridstrategy
RC200/CW100 thermostat 157 switchovertemp outside switchover temperature int8 (>=-20<=20) C True number.thermostat_outside_switchover_temperature number.thermostat_switchovertemp
RC200/CW100 thermostat 157 energycostratio energy cost ratio uint8 (>=0<=20) True number.thermostat_energy_cost_ratio number.thermostat_energycostratio
RC200/CW100 thermostat 157 fossilefactor fossile energy factor uint8 (>=0<=5) True number.thermostat_fossile_energy_factor number.thermostat_fossilefactor
RC200/CW100 thermostat 157 electricfactor electric energy factor uint8 (>=0<=5) True number.thermostat_electric_energy_factor number.thermostat_electricfactor
RC200/CW100 thermostat 157 delayboiler delay boiler support uint8 (>=5<=120) minutes True number.thermostat_delay_boiler_support number.thermostat_delayboiler
RC200/CW100 thermostat 157 tempdiffboiler temp diff boiler support uint8 (>=1<=99) C True number.thermostat_temp_diff_boiler_support number.thermostat_tempdiffboiler
RC200/CW100 thermostat 157 pvenabledhw enable raise dhw boolean True switch.thermostat_enable_raise_dhw switch.thermostat_pvenabledhw
RC200/CW100 thermostat 157 pvraiseheat raise heating with PV int8 (>=0<=5) K True number.thermostat_raise_heating_with_PV number.thermostat_pvraiseheat
RC200/CW100 thermostat 157 pvlowercool lower cooling with PV int8 (>=-5<=0) K True number.thermostat_lower_cooling_with_PV number.thermostat_pvlowercool
RC200/CW100 thermostat 157 seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp
RC200/CW100 thermostat 157 currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp
RC200/CW100 thermostat 157 haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate
RC200/CW100 thermostat 157 mode mode enum [manual|auto] True select.thermostat_hc1_mode select.thermostat_hc1_mode
RC200/CW100 thermostat 157 modetype mode type enum [eco|comfort] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype
RC200/CW100 thermostat 157 ecotemp eco temperature uint8 (>=0<=127) C True number.thermostat_hc1_eco_temperature number.thermostat_hc1_ecotemp
RC200/CW100 thermostat 157 manualtemp manual temperature uint8 (>=0<=127) C True number.thermostat_hc1_manual_temperature number.thermostat_hc1_manualtemp
RC200/CW100 thermostat 157 comforttemp comfort temperature uint8 (>=0<=127) C True number.thermostat_hc1_comfort_temperature number.thermostat_hc1_comforttemp
RC200/CW100 thermostat 157 summertemp summer temperature uint8 (>=10<=30) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp
RC200/CW100 thermostat 157 designtemp design temperature uint8 (>=0<=254) C True number.thermostat_hc1_design_temperature number.thermostat_hc1_designtemp
RC200/CW100 thermostat 157 offsettemp offset temperature int8 (>=-126<=126) C True number.thermostat_hc1_offset_temperature number.thermostat_hc1_offsettemp
RC200/CW100 thermostat 157 minflowtemp min flow temperature uint8 (>=0<=254) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp
RC200/CW100 thermostat 157 maxflowtemp max flow temperature uint8 (>=0<=254) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp
RC200/CW100 thermostat 157 roominfluence room influence uint8 (>=0<=254) C True number.thermostat_hc1_room_influence number.thermostat_hc1_roominfluence
RC200/CW100 thermostat 157 roominflfactor room influence factor uint8 (>=0<=25) True number.thermostat_hc1_room_influence_factor number.thermostat_hc1_roominflfactor
RC200/CW100 thermostat 157 curroominfl current room influence int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_influence sensor.thermostat_hc1_curroominfl
RC200/CW100 thermostat 157 nofrostmode nofrost mode enum [room|outdoor|room outdoor] True select.thermostat_hc1_nofrost_mode select.thermostat_hc1_nofrostmode
RC200/CW100 thermostat 157 nofrosttemp nofrost temperature int8 (>=-126<=126) C True number.thermostat_hc1_nofrost_temperature number.thermostat_hc1_nofrosttemp
RC200/CW100 thermostat 157 targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp
RC200/CW100 thermostat 157 heatingtype heating type enum [off|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype
RC200/CW100 thermostat 157 summersetmode set summer mode enum [summer|auto|winter] True select.thermostat_hc1_set_summer_mode select.thermostat_hc1_summersetmode
RC200/CW100 thermostat 157 hpoperatingmode heatpump operating mode enum [off|auto|heating|cooling] True select.thermostat_hc1_heatpump_operating_mode select.thermostat_hc1_hpoperatingmode
RC200/CW100 thermostat 157 summermode summer mode enum [winter|summer] False sensor.thermostat_hc1_summer_mode sensor.thermostat_hc1_summermode
RC200/CW100 thermostat 157 hpoperatingstate heatpump operating state enum [heating|off|cooling] False sensor.thermostat_hc1_heatpump_operating_state sensor.thermostat_hc1_hpoperatingstate
RC200/CW100 thermostat 157 controlmode control mode enum [optimized|simple|n/a|room|power] True select.thermostat_hc1_control_mode select.thermostat_hc1_controlmode
RC200/CW100 thermostat 157 program program enum [prog 1|prog 2] True select.thermostat_hc1_program select.thermostat_hc1_program
RC200/CW100 thermostat 157 tempautotemp temporary set temperature automode int8 (>=-1<=30) C True number.thermostat_hc1_temporary_set_temperature_automode number.thermostat_hc1_tempautotemp
RC200/CW100 thermostat 157 remoteseltemp temporary set temperature from remote int8 (>=-63<=63) C False sensor.thermostat_hc1_temporary_set_temperature_from_remote sensor.thermostat_hc1_remoteseltemp
RC200/CW100 thermostat 157 fastheatup fast heatup uint8 (>=0<=100) % True number.thermostat_hc1_fast_heatup number.thermostat_hc1_fastheatup
RC200/CW100 thermostat 157 switchonoptimization switch-on optimization boolean True switch.thermostat_hc1_switch-on_optimization switch.thermostat_hc1_switchonoptimization
RC200/CW100 thermostat 157 reducemode reduce mode enum [outdoor|room|reduce] True select.thermostat_hc1_reduce_mode select.thermostat_hc1_reducemode
RC200/CW100 thermostat 157 noreducetemp no reduce below temperature int8 (>=-126<=126) C True number.thermostat_hc1_no_reduce_below_temperature number.thermostat_hc1_noreducetemp
RC200/CW100 thermostat 157 reducetemp off/reduce switch temperature int8 (>=-126<=126) C True number.thermostat_hc1_off/reduce_switch_temperature number.thermostat_hc1_reducetemp
RC200/CW100 thermostat 157 dhwprio dhw priority boolean True switch.thermostat_hc1_dhw_priority switch.thermostat_hc1_dhwprio
RC200/CW100 thermostat 157 cooling cooling boolean True switch.thermostat_hc1_cooling switch.thermostat_hc1_cooling
RC200/CW100 thermostat 157 coolingon cooling boolean False binary_sensor.thermostat_hc1_cooling binary_sensor.thermostat_hc1_coolingon
RC200/CW100 thermostat 157 hpmode HP Mode enum [heating|cooling|heating&cooling] True select.thermostat_hc1_HP_Mode select.thermostat_hc1_hpmode
RC200/CW100 thermostat 157 dewoffset dew point offset uint8 (>=2<=10) K True number.thermostat_hc1_dew_point_offset number.thermostat_hc1_dewoffset
RC200/CW100 thermostat 157 roomtempdiff room temp difference uint8 (>=0<=254) K True number.thermostat_hc1_room_temp_difference number.thermostat_hc1_roomtempdiff
RC200/CW100 thermostat 157 hpminflowtemp HP min. flow temp. uint8 (>=0<=254) C True number.thermostat_hc1_HP_min._flow_temp. number.thermostat_hc1_hpminflowtemp
RC200/CW100 thermostat 157 control control device enum [RC310|RC200|RC100|RC100H|TC100] True select.thermostat_hc1_control_device select.thermostat_hc1_control
RC200/CW100 thermostat 157 remotetemp room temperature from remote int16 (>=-1<=101) C True number.thermostat_hc1_room_temperature_from_remote number.thermostat_hc1_remotetemp
RC200/CW100 thermostat 157 remotehum room humidity from remote uint8 (>=-1<=101) % True number.thermostat_hc1_room_humidity_from_remote number.thermostat_hc1_remotehum
RC200/CW100 thermostat 157 heatondelay heat-on delay uint8 (>=1<=48) hours True number.thermostat_hc1_heat-on_delay number.thermostat_hc1_heatondelay
RC200/CW100 thermostat 157 heatoffdelay heat-off delay uint8 (>=1<=48) hours True number.thermostat_hc1_heat-off_delay number.thermostat_hc1_heatoffdelay
RC200/CW100 thermostat 157 instantstart instant start uint8 (>=1<=10) K True number.thermostat_hc1_instant_start number.thermostat_hc1_instantstart
RC200/CW100 thermostat 157 boost boost mode boolean True switch.thermostat_hc1_boost_mode switch.thermostat_hc1_boost
RC200/CW100 thermostat 157 boosttime boost time uint8 (>=0<=254) hours True number.thermostat_hc1_boost_time number.thermostat_hc1_boosttime
RC200/CW100 thermostat 157 mode mode enum [off|normal|comfort|auto|own prog] True select.thermostat_dhw_mode select.thermostat_dhw_mode
RC200/CW100 thermostat 157 settemp set temperature uint8 (>=0<=254) C True number.thermostat_dhw_set_temperature number.thermostat_dhw_settemp
RC200/CW100 thermostat 157 settemplow set low temperature uint8 (>=0<=254) C True number.thermostat_dhw_set_low_temperature number.thermostat_dhw_settemplow
RC200/CW100 thermostat 157 circmode circulation pump mode enum [off|on|auto|own prog] True select.thermostat_dhw_circulation_pump_mode select.thermostat_dhw_circmode
RC200/CW100 thermostat 157 chargeduration charge duration uint8 (>=0<=3810) minutes True number.thermostat_dhw_charge_duration number.thermostat_dhw_chargeduration
RC200/CW100 thermostat 157 charge charge boolean True switch.thermostat_dhw_charge switch.thermostat_dhw_charge
RC200/CW100 thermostat 157 extra extra uint8 (>=0<=254) C False sensor.thermostat_dhw_extra sensor.thermostat_dhw_extra
RC200/CW100 thermostat 157 disinfecting disinfecting boolean True switch.thermostat_dhw_disinfecting switch.thermostat_dhw_disinfecting
RC200/CW100 thermostat 157 disinfectday disinfection day enum [mo|tu|we|th|fr|sa|su|all] True select.thermostat_dhw_disinfection_day select.thermostat_dhw_disinfectday
RC200/CW100 thermostat 157 disinfecttime disinfection time uint8 (>=0<=1431) minutes True number.thermostat_dhw_disinfection_time number.thermostat_dhw_disinfecttime
RC200/CW100 thermostat 157 dailyheating daily heating boolean True switch.thermostat_dhw_daily_heating switch.thermostat_dhw_dailyheating
RC200/CW100 thermostat 157 dailyheattime daily heating time uint8 (>=0<=1431) minutes True number.thermostat_dhw_daily_heating_time number.thermostat_dhw_dailyheattime
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 datetime date/time string True sensor.thermostat_date/time sensor.thermostat_datetime
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 intoffset internal temperature offset int8 (>=-12<=12) C True number.thermostat_internal_temperature_offset number.thermostat_intoffset
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 floordry floor drying enum [off|start|heat|hold|cool|end] False sensor.thermostat_floor_drying sensor.thermostat_floordry
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 dampedoutdoortemp damped outdoor temperature int16 (>=-3199<=3199) C False sensor.thermostat_damped_outdoor_temperature sensor.thermostat_dampedoutdoortemp
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 floordrytemp floor drying temperature uint8 (>=0<=254) C False sensor.thermostat_floor_drying_temperature sensor.thermostat_floordrytemp
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 building building type enum [light|medium|heavy] True select.thermostat_building_type select.thermostat_building
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 minexttemp minimal external temperature int8 (>=-126<=126) C True number.thermostat_minimal_external_temperature number.thermostat_minexttemp
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 damping damping outdoor temperature boolean True switch.thermostat_damping_outdoor_temperature switch.thermostat_damping
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 hybridstrategy hybrid control strategy enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] True select.thermostat_hybrid_control_strategy select.thermostat_hybridstrategy
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 switchovertemp outside switchover temperature int8 (>=-20<=20) C True number.thermostat_outside_switchover_temperature number.thermostat_switchovertemp
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 energycostratio energy cost ratio uint8 (>=0<=20) True number.thermostat_energy_cost_ratio number.thermostat_energycostratio
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 fossilefactor fossile energy factor uint8 (>=0<=5) True number.thermostat_fossile_energy_factor number.thermostat_fossilefactor
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 electricfactor electric energy factor uint8 (>=0<=5) True number.thermostat_electric_energy_factor number.thermostat_electricfactor
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 delayboiler delay boiler support uint8 (>=5<=120) minutes True number.thermostat_delay_boiler_support number.thermostat_delayboiler
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 tempdiffboiler temp diff boiler support uint8 (>=1<=99) C True number.thermostat_temp_diff_boiler_support number.thermostat_tempdiffboiler
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 pvenabledhw enable raise dhw boolean True switch.thermostat_enable_raise_dhw switch.thermostat_pvenabledhw
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 pvraiseheat raise heating with PV int8 (>=0<=5) K True number.thermostat_raise_heating_with_PV number.thermostat_pvraiseheat
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 pvlowercool lower cooling with PV int8 (>=-5<=0) K True number.thermostat_lower_cooling_with_PV number.thermostat_pvlowercool
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 mode mode enum [manual|auto] True select.thermostat_hc1_mode select.thermostat_hc1_mode
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 modetype mode type enum [eco|comfort] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 ecotemp eco temperature uint8 (>=0<=127) C True number.thermostat_hc1_eco_temperature number.thermostat_hc1_ecotemp
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 manualtemp manual temperature uint8 (>=0<=127) C True number.thermostat_hc1_manual_temperature number.thermostat_hc1_manualtemp
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 comforttemp comfort temperature uint8 (>=0<=127) C True number.thermostat_hc1_comfort_temperature number.thermostat_hc1_comforttemp
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 summertemp summer temperature uint8 (>=10<=30) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 designtemp design temperature uint8 (>=0<=254) C True number.thermostat_hc1_design_temperature number.thermostat_hc1_designtemp
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 offsettemp offset temperature int8 (>=-126<=126) C True number.thermostat_hc1_offset_temperature number.thermostat_hc1_offsettemp
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 minflowtemp min flow temperature uint8 (>=0<=254) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 maxflowtemp max flow temperature uint8 (>=0<=254) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 roominfluence room influence uint8 (>=0<=254) C True number.thermostat_hc1_room_influence number.thermostat_hc1_roominfluence
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 roominflfactor room influence factor uint8 (>=0<=25) True number.thermostat_hc1_room_influence_factor number.thermostat_hc1_roominflfactor
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 curroominfl current room influence int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_influence sensor.thermostat_hc1_curroominfl
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 nofrostmode nofrost mode enum [room|outdoor|room outdoor] True select.thermostat_hc1_nofrost_mode select.thermostat_hc1_nofrostmode
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 nofrosttemp nofrost temperature int8 (>=-126<=126) C True number.thermostat_hc1_nofrost_temperature number.thermostat_hc1_nofrosttemp
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 heatingtype heating type enum [off|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 summersetmode set summer mode enum [summer|auto|winter] True select.thermostat_hc1_set_summer_mode select.thermostat_hc1_summersetmode
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 hpoperatingmode heatpump operating mode enum [off|auto|heating|cooling] True select.thermostat_hc1_heatpump_operating_mode select.thermostat_hc1_hpoperatingmode
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 summermode summer mode enum [winter|summer] False sensor.thermostat_hc1_summer_mode sensor.thermostat_hc1_summermode
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 hpoperatingstate heatpump operating state enum [heating|off|cooling] False sensor.thermostat_hc1_heatpump_operating_state sensor.thermostat_hc1_hpoperatingstate
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 controlmode control mode enum [weather compensated|outside basepoint|n/a|room|power|constant] True select.thermostat_hc1_control_mode select.thermostat_hc1_controlmode
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 program program enum [prog 1|prog 2] True select.thermostat_hc1_program select.thermostat_hc1_program
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 tempautotemp temporary set temperature automode int8 (>=-1<=30) C True number.thermostat_hc1_temporary_set_temperature_automode number.thermostat_hc1_tempautotemp
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 remoteseltemp temporary set temperature from remote int8 (>=-63<=63) C False sensor.thermostat_hc1_temporary_set_temperature_from_remote sensor.thermostat_hc1_remoteseltemp
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 fastheatup fast heatup uint8 (>=0<=100) % True number.thermostat_hc1_fast_heatup number.thermostat_hc1_fastheatup
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 switchonoptimization switch-on optimization boolean True switch.thermostat_hc1_switch-on_optimization switch.thermostat_hc1_switchonoptimization
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 reducemode reduce mode enum [outdoor|room|reduce] True select.thermostat_hc1_reduce_mode select.thermostat_hc1_reducemode
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 noreducetemp no reduce below temperature int8 (>=-126<=126) C True number.thermostat_hc1_no_reduce_below_temperature number.thermostat_hc1_noreducetemp
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 reducetemp off/reduce switch temperature int8 (>=-126<=126) C True number.thermostat_hc1_off/reduce_switch_temperature number.thermostat_hc1_reducetemp
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 dhwprio dhw priority boolean True switch.thermostat_hc1_dhw_priority switch.thermostat_hc1_dhwprio
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 cooling cooling boolean True switch.thermostat_hc1_cooling switch.thermostat_hc1_cooling
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 coolingon cooling boolean False binary_sensor.thermostat_hc1_cooling binary_sensor.thermostat_hc1_coolingon
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 hpmode HP Mode enum [heating|cooling|heating&cooling] True select.thermostat_hc1_HP_Mode select.thermostat_hc1_hpmode
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 dewoffset dew point offset uint8 (>=2<=10) K True number.thermostat_hc1_dew_point_offset number.thermostat_hc1_dewoffset
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 roomtempdiff room temp difference uint8 (>=0<=254) K True number.thermostat_hc1_room_temp_difference number.thermostat_hc1_roomtempdiff
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 hpminflowtemp HP min. flow temp. uint8 (>=0<=254) C True number.thermostat_hc1_HP_min._flow_temp. number.thermostat_hc1_hpminflowtemp
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 control control device enum [RC310|RC200|RC100|RC100H|TC100] True select.thermostat_hc1_control_device select.thermostat_hc1_control
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 remotetemp room temperature from remote int16 (>=-1<=101) C True number.thermostat_hc1_room_temperature_from_remote number.thermostat_hc1_remotetemp
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 remotehum room humidity from remote uint8 (>=-1<=101) % True number.thermostat_hc1_room_humidity_from_remote number.thermostat_hc1_remotehum
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 heatondelay heat-on delay uint8 (>=1<=48) hours True number.thermostat_hc1_heat-on_delay number.thermostat_hc1_heatondelay
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 heatoffdelay heat-off delay uint8 (>=1<=48) hours True number.thermostat_hc1_heat-off_delay number.thermostat_hc1_heatoffdelay
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 instantstart instant start uint8 (>=1<=10) K True number.thermostat_hc1_instant_start number.thermostat_hc1_instantstart
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 boost boost mode boolean True switch.thermostat_hc1_boost_mode switch.thermostat_hc1_boost
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 boosttime boost time uint8 (>=0<=254) hours True number.thermostat_hc1_boost_time number.thermostat_hc1_boosttime
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 mode mode enum [off|normal|comfort|auto|own prog] True select.thermostat_dhw_mode select.thermostat_dhw_mode
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 settemp set temperature uint8 (>=0<=254) C True number.thermostat_dhw_set_temperature number.thermostat_dhw_settemp
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 settemplow set low temperature uint8 (>=0<=254) C True number.thermostat_dhw_set_low_temperature number.thermostat_dhw_settemplow
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 circmode circulation pump mode enum [off|on|auto|own prog] True select.thermostat_dhw_circulation_pump_mode select.thermostat_dhw_circmode
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 chargeduration charge duration uint8 (>=0<=3810) minutes True number.thermostat_dhw_charge_duration number.thermostat_dhw_chargeduration
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 charge charge boolean True switch.thermostat_dhw_charge switch.thermostat_dhw_charge
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 extra extra uint8 (>=0<=254) C False sensor.thermostat_dhw_extra sensor.thermostat_dhw_extra
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 disinfecting disinfecting boolean True switch.thermostat_dhw_disinfecting switch.thermostat_dhw_disinfecting
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 disinfectday disinfection day enum [mo|tu|we|th|fr|sa|su|all] True select.thermostat_dhw_disinfection_day select.thermostat_dhw_disinfectday
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 disinfecttime disinfection time uint8 (>=0<=1431) minutes True number.thermostat_dhw_disinfection_time number.thermostat_dhw_disinfecttime
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 dailyheating daily heating boolean True switch.thermostat_dhw_daily_heating switch.thermostat_dhw_dailyheating
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 thermostat 158 dailyheattime daily heating time uint8 (>=0<=1431) minutes True number.thermostat_dhw_daily_heating_time number.thermostat_dhw_dailyheattime
RC100/Moduline 1000/1010 thermostat 165 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode
RC100/Moduline 1000/1010 thermostat 165 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode
RC100/Moduline 1000/1010 thermostat 165 datetime date/time string True sensor.thermostat_date/time sensor.thermostat_datetime
RC100/Moduline 1000/1010 thermostat 165 intoffset internal temperature offset int8 (>=-12<=12) C True number.thermostat_internal_temperature_offset number.thermostat_intoffset
RC100/Moduline 1000/1010 thermostat 165 floordry floor drying enum [off|start|heat|hold|cool|end] False sensor.thermostat_floor_drying sensor.thermostat_floordry
RC100/Moduline 1000/1010 thermostat 165 dampedoutdoortemp damped outdoor temperature int16 (>=-3199<=3199) C False sensor.thermostat_damped_outdoor_temperature sensor.thermostat_dampedoutdoortemp
RC100/Moduline 1000/1010 thermostat 165 floordrytemp floor drying temperature uint8 (>=0<=254) C False sensor.thermostat_floor_drying_temperature sensor.thermostat_floordrytemp
RC100/Moduline 1000/1010 thermostat 165 building building type enum [light|medium|heavy] True select.thermostat_building_type select.thermostat_building
RC100/Moduline 1000/1010 thermostat 165 minexttemp minimal external temperature int8 (>=-126<=126) C True number.thermostat_minimal_external_temperature number.thermostat_minexttemp
RC100/Moduline 1000/1010 thermostat 165 damping damping outdoor temperature boolean True switch.thermostat_damping_outdoor_temperature switch.thermostat_damping
RC100/Moduline 1000/1010 thermostat 165 hybridstrategy hybrid control strategy enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] True select.thermostat_hybrid_control_strategy select.thermostat_hybridstrategy
RC100/Moduline 1000/1010 thermostat 165 switchovertemp outside switchover temperature int8 (>=-20<=20) C True number.thermostat_outside_switchover_temperature number.thermostat_switchovertemp
RC100/Moduline 1000/1010 thermostat 165 energycostratio energy cost ratio uint8 (>=0<=20) True number.thermostat_energy_cost_ratio number.thermostat_energycostratio
RC100/Moduline 1000/1010 thermostat 165 fossilefactor fossile energy factor uint8 (>=0<=5) True number.thermostat_fossile_energy_factor number.thermostat_fossilefactor
RC100/Moduline 1000/1010 thermostat 165 electricfactor electric energy factor uint8 (>=0<=5) True number.thermostat_electric_energy_factor number.thermostat_electricfactor
RC100/Moduline 1000/1010 thermostat 165 delayboiler delay boiler support uint8 (>=5<=120) minutes True number.thermostat_delay_boiler_support number.thermostat_delayboiler
RC100/Moduline 1000/1010 thermostat 165 tempdiffboiler temp diff boiler support uint8 (>=1<=99) C True number.thermostat_temp_diff_boiler_support number.thermostat_tempdiffboiler
RC100/Moduline 1000/1010 thermostat 165 pvenabledhw enable raise dhw boolean True switch.thermostat_enable_raise_dhw switch.thermostat_pvenabledhw
RC100/Moduline 1000/1010 thermostat 165 pvraiseheat raise heating with PV int8 (>=0<=5) K True number.thermostat_raise_heating_with_PV number.thermostat_pvraiseheat
RC100/Moduline 1000/1010 thermostat 165 pvlowercool lower cooling with PV int8 (>=-5<=0) K True number.thermostat_lower_cooling_with_PV number.thermostat_pvlowercool
RC100/Moduline 1000/1010 thermostat 165 seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp
RC100/Moduline 1000/1010 thermostat 165 currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp
RC100/Moduline 1000/1010 thermostat 165 haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate
RC100/Moduline 1000/1010 thermostat 165 mode mode enum [manual|auto] True select.thermostat_hc1_mode select.thermostat_hc1_mode
RC100/Moduline 1000/1010 thermostat 165 modetype mode type enum [eco|comfort] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype
RC100/Moduline 1000/1010 thermostat 165 ecotemp eco temperature uint8 (>=0<=127) C True number.thermostat_hc1_eco_temperature number.thermostat_hc1_ecotemp
RC100/Moduline 1000/1010 thermostat 165 manualtemp manual temperature uint8 (>=0<=127) C True number.thermostat_hc1_manual_temperature number.thermostat_hc1_manualtemp
RC100/Moduline 1000/1010 thermostat 165 comforttemp comfort temperature uint8 (>=0<=127) C True number.thermostat_hc1_comfort_temperature number.thermostat_hc1_comforttemp
RC100/Moduline 1000/1010 thermostat 165 summertemp summer temperature uint8 (>=10<=30) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp
RC100/Moduline 1000/1010 thermostat 165 designtemp design temperature uint8 (>=0<=254) C True number.thermostat_hc1_design_temperature number.thermostat_hc1_designtemp
RC100/Moduline 1000/1010 thermostat 165 offsettemp offset temperature int8 (>=-126<=126) C True number.thermostat_hc1_offset_temperature number.thermostat_hc1_offsettemp
RC100/Moduline 1000/1010 thermostat 165 minflowtemp min flow temperature uint8 (>=0<=254) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp
RC100/Moduline 1000/1010 thermostat 165 maxflowtemp max flow temperature uint8 (>=0<=254) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp
RC100/Moduline 1000/1010 thermostat 165 roominfluence room influence uint8 (>=0<=254) C True number.thermostat_hc1_room_influence number.thermostat_hc1_roominfluence
RC100/Moduline 1000/1010 thermostat 165 roominflfactor room influence factor uint8 (>=0<=25) True number.thermostat_hc1_room_influence_factor number.thermostat_hc1_roominflfactor
RC100/Moduline 1000/1010 thermostat 165 curroominfl current room influence int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_influence sensor.thermostat_hc1_curroominfl
RC100/Moduline 1000/1010 thermostat 165 nofrostmode nofrost mode enum [room|outdoor|room outdoor] True select.thermostat_hc1_nofrost_mode select.thermostat_hc1_nofrostmode
RC100/Moduline 1000/1010 thermostat 165 nofrosttemp nofrost temperature int8 (>=-126<=126) C True number.thermostat_hc1_nofrost_temperature number.thermostat_hc1_nofrosttemp
RC100/Moduline 1000/1010 thermostat 165 targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp
RC100/Moduline 1000/1010 thermostat 165 heatingtype heating type enum [off|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype
RC100/Moduline 1000/1010 thermostat 165 summersetmode set summer mode enum [summer|auto|winter] True select.thermostat_hc1_set_summer_mode select.thermostat_hc1_summersetmode
RC100/Moduline 1000/1010 thermostat 165 hpoperatingmode heatpump operating mode enum [off|auto|heating|cooling] True select.thermostat_hc1_heatpump_operating_mode select.thermostat_hc1_hpoperatingmode
RC100/Moduline 1000/1010 thermostat 165 summermode summer mode enum [winter|summer] False sensor.thermostat_hc1_summer_mode sensor.thermostat_hc1_summermode
RC100/Moduline 1000/1010 thermostat 165 hpoperatingstate heatpump operating state enum [heating|off|cooling] False sensor.thermostat_hc1_heatpump_operating_state sensor.thermostat_hc1_hpoperatingstate
RC100/Moduline 1000/1010 thermostat 165 controlmode control mode enum [optimized|simple|n/a|room|power] True select.thermostat_hc1_control_mode select.thermostat_hc1_controlmode
RC100/Moduline 1000/1010 thermostat 165 program program enum [prog 1|prog 2] True select.thermostat_hc1_program select.thermostat_hc1_program
RC100/Moduline 1000/1010 thermostat 165 tempautotemp temporary set temperature automode int8 (>=-1<=30) C True number.thermostat_hc1_temporary_set_temperature_automode number.thermostat_hc1_tempautotemp
RC100/Moduline 1000/1010 thermostat 165 remoteseltemp temporary set temperature from remote int8 (>=-63<=63) C False sensor.thermostat_hc1_temporary_set_temperature_from_remote sensor.thermostat_hc1_remoteseltemp
RC100/Moduline 1000/1010 thermostat 165 fastheatup fast heatup uint8 (>=0<=100) % True number.thermostat_hc1_fast_heatup number.thermostat_hc1_fastheatup
RC100/Moduline 1000/1010 thermostat 165 switchonoptimization switch-on optimization boolean True switch.thermostat_hc1_switch-on_optimization switch.thermostat_hc1_switchonoptimization
RC100/Moduline 1000/1010 thermostat 165 reducemode reduce mode enum [outdoor|room|reduce] True select.thermostat_hc1_reduce_mode select.thermostat_hc1_reducemode
RC100/Moduline 1000/1010 thermostat 165 noreducetemp no reduce below temperature int8 (>=-126<=126) C True number.thermostat_hc1_no_reduce_below_temperature number.thermostat_hc1_noreducetemp
RC100/Moduline 1000/1010 thermostat 165 reducetemp off/reduce switch temperature int8 (>=-126<=126) C True number.thermostat_hc1_off/reduce_switch_temperature number.thermostat_hc1_reducetemp
RC100/Moduline 1000/1010 thermostat 165 dhwprio dhw priority boolean True switch.thermostat_hc1_dhw_priority switch.thermostat_hc1_dhwprio
RC100/Moduline 1000/1010 thermostat 165 cooling cooling boolean True switch.thermostat_hc1_cooling switch.thermostat_hc1_cooling
RC100/Moduline 1000/1010 thermostat 165 coolingon cooling boolean False binary_sensor.thermostat_hc1_cooling binary_sensor.thermostat_hc1_coolingon
RC100/Moduline 1000/1010 thermostat 165 hpmode HP Mode enum [heating|cooling|heating&cooling] True select.thermostat_hc1_HP_Mode select.thermostat_hc1_hpmode
RC100/Moduline 1000/1010 thermostat 165 dewoffset dew point offset uint8 (>=2<=10) K True number.thermostat_hc1_dew_point_offset number.thermostat_hc1_dewoffset
RC100/Moduline 1000/1010 thermostat 165 roomtempdiff room temp difference uint8 (>=0<=254) K True number.thermostat_hc1_room_temp_difference number.thermostat_hc1_roomtempdiff
RC100/Moduline 1000/1010 thermostat 165 hpminflowtemp HP min. flow temp. uint8 (>=0<=254) C True number.thermostat_hc1_HP_min._flow_temp. number.thermostat_hc1_hpminflowtemp
RC100/Moduline 1000/1010 thermostat 165 control control device enum [RC310|RC200|RC100|RC100H|TC100] True select.thermostat_hc1_control_device select.thermostat_hc1_control
RC100/Moduline 1000/1010 thermostat 165 remotetemp room temperature from remote int16 (>=-1<=101) C True number.thermostat_hc1_room_temperature_from_remote number.thermostat_hc1_remotetemp
RC100/Moduline 1000/1010 thermostat 165 remotehum room humidity from remote uint8 (>=-1<=101) % True number.thermostat_hc1_room_humidity_from_remote number.thermostat_hc1_remotehum
RC100/Moduline 1000/1010 thermostat 165 heatondelay heat-on delay uint8 (>=1<=48) hours True number.thermostat_hc1_heat-on_delay number.thermostat_hc1_heatondelay
RC100/Moduline 1000/1010 thermostat 165 heatoffdelay heat-off delay uint8 (>=1<=48) hours True number.thermostat_hc1_heat-off_delay number.thermostat_hc1_heatoffdelay
RC100/Moduline 1000/1010 thermostat 165 instantstart instant start uint8 (>=1<=10) K True number.thermostat_hc1_instant_start number.thermostat_hc1_instantstart
RC100/Moduline 1000/1010 thermostat 165 boost boost mode boolean True switch.thermostat_hc1_boost_mode switch.thermostat_hc1_boost
RC100/Moduline 1000/1010 thermostat 165 boosttime boost time uint8 (>=0<=254) hours True number.thermostat_hc1_boost_time number.thermostat_hc1_boosttime
RC100/Moduline 1000/1010 thermostat 165 mode mode enum [off|normal|comfort|auto|own prog] True select.thermostat_dhw_mode select.thermostat_dhw_mode
RC100/Moduline 1000/1010 thermostat 165 settemp set temperature uint8 (>=0<=254) C True number.thermostat_dhw_set_temperature number.thermostat_dhw_settemp
RC100/Moduline 1000/1010 thermostat 165 settemplow set low temperature uint8 (>=0<=254) C True number.thermostat_dhw_set_low_temperature number.thermostat_dhw_settemplow
RC100/Moduline 1000/1010 thermostat 165 circmode circulation pump mode enum [off|on|auto|own prog] True select.thermostat_dhw_circulation_pump_mode select.thermostat_dhw_circmode
RC100/Moduline 1000/1010 thermostat 165 chargeduration charge duration uint8 (>=0<=3810) minutes True number.thermostat_dhw_charge_duration number.thermostat_dhw_chargeduration
RC100/Moduline 1000/1010 thermostat 165 charge charge boolean True switch.thermostat_dhw_charge switch.thermostat_dhw_charge
RC100/Moduline 1000/1010 thermostat 165 extra extra uint8 (>=0<=254) C False sensor.thermostat_dhw_extra sensor.thermostat_dhw_extra
RC100/Moduline 1000/1010 thermostat 165 disinfecting disinfecting boolean True switch.thermostat_dhw_disinfecting switch.thermostat_dhw_disinfecting
RC100/Moduline 1000/1010 thermostat 165 disinfectday disinfection day enum [mo|tu|we|th|fr|sa|su|all] True select.thermostat_dhw_disinfection_day select.thermostat_dhw_disinfectday
RC100/Moduline 1000/1010 thermostat 165 disinfecttime disinfection time uint8 (>=0<=1431) minutes True number.thermostat_dhw_disinfection_time number.thermostat_dhw_disinfecttime
RC100/Moduline 1000/1010 thermostat 165 dailyheating daily heating boolean True switch.thermostat_dhw_daily_heating switch.thermostat_dhw_dailyheating
RC100/Moduline 1000/1010 thermostat 165 dailyheattime daily heating time uint8 (>=0<=1431) minutes True number.thermostat_dhw_daily_heating_time number.thermostat_dhw_dailyheattime
Rego 2000/3000 thermostat 172 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode
Rego 2000/3000 thermostat 172 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode
Rego 2000/3000 thermostat 172 datetime date/time string True sensor.thermostat_date/time sensor.thermostat_datetime
Rego 2000/3000 thermostat 172 intoffset internal temperature offset int8 (>=-12<=12) C True number.thermostat_internal_temperature_offset number.thermostat_intoffset
Rego 2000/3000 thermostat 172 floordry floor drying enum [off|start|heat|hold|cool|end] False sensor.thermostat_floor_drying sensor.thermostat_floordry
Rego 2000/3000 thermostat 172 dampedoutdoortemp damped outdoor temperature int16 (>=-3199<=3199) C False sensor.thermostat_damped_outdoor_temperature sensor.thermostat_dampedoutdoortemp
Rego 2000/3000 thermostat 172 floordrytemp floor drying temperature uint8 (>=0<=254) C False sensor.thermostat_floor_drying_temperature sensor.thermostat_floordrytemp
Rego 2000/3000 thermostat 172 building building type enum [light|medium|heavy] True select.thermostat_building_type select.thermostat_building
Rego 2000/3000 thermostat 172 minexttemp minimal external temperature int8 (>=-126<=126) C True number.thermostat_minimal_external_temperature number.thermostat_minexttemp
Rego 2000/3000 thermostat 172 damping damping outdoor temperature boolean True switch.thermostat_damping_outdoor_temperature switch.thermostat_damping
Rego 2000/3000 thermostat 172 hybridstrategy hybrid control strategy enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] True select.thermostat_hybrid_control_strategy select.thermostat_hybridstrategy
Rego 2000/3000 thermostat 172 switchovertemp outside switchover temperature int8 (>=-20<=20) C True number.thermostat_outside_switchover_temperature number.thermostat_switchovertemp
Rego 2000/3000 thermostat 172 energycostratio energy cost ratio uint8 (>=0<=20) True number.thermostat_energy_cost_ratio number.thermostat_energycostratio
Rego 2000/3000 thermostat 172 fossilefactor fossile energy factor uint8 (>=0<=5) True number.thermostat_fossile_energy_factor number.thermostat_fossilefactor
Rego 2000/3000 thermostat 172 electricfactor electric energy factor uint8 (>=0<=5) True number.thermostat_electric_energy_factor number.thermostat_electricfactor
Rego 2000/3000 thermostat 172 delayboiler delay boiler support uint8 (>=5<=120) minutes True number.thermostat_delay_boiler_support number.thermostat_delayboiler
Rego 2000/3000 thermostat 172 tempdiffboiler temp diff boiler support uint8 (>=1<=99) C True number.thermostat_temp_diff_boiler_support number.thermostat_tempdiffboiler
Rego 2000/3000 thermostat 172 pvenabledhw enable raise dhw boolean True switch.thermostat_enable_raise_dhw switch.thermostat_pvenabledhw
Rego 2000/3000 thermostat 172 pvraiseheat raise heating with PV int8 (>=0<=5) K True number.thermostat_raise_heating_with_PV number.thermostat_pvraiseheat
Rego 2000/3000 thermostat 172 pvlowercool lower cooling with PV int8 (>=-5<=0) K True number.thermostat_lower_cooling_with_PV number.thermostat_pvlowercool
Rego 2000/3000 thermostat 172 seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp
Rego 2000/3000 thermostat 172 currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp
Rego 2000/3000 thermostat 172 haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate
Rego 2000/3000 thermostat 172 mode mode enum [manual|auto] True select.thermostat_hc1_mode select.thermostat_hc1_mode
Rego 2000/3000 thermostat 172 modetype mode type enum [eco|comfort] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype
Rego 2000/3000 thermostat 172 ecotemp eco temperature uint8 (>=0<=127) C True number.thermostat_hc1_eco_temperature number.thermostat_hc1_ecotemp
Rego 2000/3000 thermostat 172 manualtemp manual temperature uint8 (>=0<=127) C True number.thermostat_hc1_manual_temperature number.thermostat_hc1_manualtemp
Rego 2000/3000 thermostat 172 comforttemp comfort temperature uint8 (>=0<=127) C True number.thermostat_hc1_comfort_temperature number.thermostat_hc1_comforttemp
Rego 2000/3000 thermostat 172 summertemp summer temperature uint8 (>=10<=30) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp
Rego 2000/3000 thermostat 172 designtemp design temperature uint8 (>=0<=254) C True number.thermostat_hc1_design_temperature number.thermostat_hc1_designtemp
Rego 2000/3000 thermostat 172 offsettemp offset temperature int8 (>=-126<=126) C True number.thermostat_hc1_offset_temperature number.thermostat_hc1_offsettemp
Rego 2000/3000 thermostat 172 minflowtemp min flow temperature uint8 (>=0<=254) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp
Rego 2000/3000 thermostat 172 maxflowtemp max flow temperature uint8 (>=0<=254) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp
Rego 2000/3000 thermostat 172 roominfluence room influence uint8 (>=0<=254) C True number.thermostat_hc1_room_influence number.thermostat_hc1_roominfluence
Rego 2000/3000 thermostat 172 roominflfactor room influence factor uint8 (>=0<=25) True number.thermostat_hc1_room_influence_factor number.thermostat_hc1_roominflfactor
Rego 2000/3000 thermostat 172 curroominfl current room influence int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_influence sensor.thermostat_hc1_curroominfl
Rego 2000/3000 thermostat 172 nofrostmode nofrost mode enum [room|outdoor|room outdoor] True select.thermostat_hc1_nofrost_mode select.thermostat_hc1_nofrostmode
Rego 2000/3000 thermostat 172 nofrosttemp nofrost temperature int8 (>=-126<=126) C True number.thermostat_hc1_nofrost_temperature number.thermostat_hc1_nofrosttemp
Rego 2000/3000 thermostat 172 targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp
Rego 2000/3000 thermostat 172 heatingtype heating type enum [off|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype
Rego 2000/3000 thermostat 172 summersetmode set summer mode enum [summer|auto|winter] True select.thermostat_hc1_set_summer_mode select.thermostat_hc1_summersetmode
Rego 2000/3000 thermostat 172 hpoperatingmode heatpump operating mode enum [off|auto|heating|cooling] True select.thermostat_hc1_heatpump_operating_mode select.thermostat_hc1_hpoperatingmode
Rego 2000/3000 thermostat 172 summermode summer mode enum [winter|summer] False sensor.thermostat_hc1_summer_mode sensor.thermostat_hc1_summermode
Rego 2000/3000 thermostat 172 hpoperatingstate heatpump operating state enum [heating|off|cooling] False sensor.thermostat_hc1_heatpump_operating_state sensor.thermostat_hc1_hpoperatingstate
Rego 2000/3000 thermostat 172 controlmode control mode enum [weather compensated|outside basepoint|n/a|room|power|constant] True select.thermostat_hc1_control_mode select.thermostat_hc1_controlmode
Rego 2000/3000 thermostat 172 program program enum [prog 1|prog 2] True select.thermostat_hc1_program select.thermostat_hc1_program
Rego 2000/3000 thermostat 172 tempautotemp temporary set temperature automode int8 (>=-1<=30) C True number.thermostat_hc1_temporary_set_temperature_automode number.thermostat_hc1_tempautotemp
Rego 2000/3000 thermostat 172 remoteseltemp temporary set temperature from remote int8 (>=-63<=63) C False sensor.thermostat_hc1_temporary_set_temperature_from_remote sensor.thermostat_hc1_remoteseltemp
Rego 2000/3000 thermostat 172 fastheatup fast heatup uint8 (>=0<=100) % True number.thermostat_hc1_fast_heatup number.thermostat_hc1_fastheatup
Rego 2000/3000 thermostat 172 switchonoptimization switch-on optimization boolean True switch.thermostat_hc1_switch-on_optimization switch.thermostat_hc1_switchonoptimization
Rego 2000/3000 thermostat 172 reducemode reduce mode enum [outdoor|room|reduce] True select.thermostat_hc1_reduce_mode select.thermostat_hc1_reducemode
Rego 2000/3000 thermostat 172 noreducetemp no reduce below temperature int8 (>=-126<=126) C True number.thermostat_hc1_no_reduce_below_temperature number.thermostat_hc1_noreducetemp
Rego 2000/3000 thermostat 172 reducetemp off/reduce switch temperature int8 (>=-126<=126) C True number.thermostat_hc1_off/reduce_switch_temperature number.thermostat_hc1_reducetemp
Rego 2000/3000 thermostat 172 dhwprio dhw priority boolean True switch.thermostat_hc1_dhw_priority switch.thermostat_hc1_dhwprio
Rego 2000/3000 thermostat 172 cooling cooling boolean True switch.thermostat_hc1_cooling switch.thermostat_hc1_cooling
Rego 2000/3000 thermostat 172 coolingon cooling boolean False binary_sensor.thermostat_hc1_cooling binary_sensor.thermostat_hc1_coolingon
Rego 2000/3000 thermostat 172 hpmode HP Mode enum [heating|cooling|heating&cooling] True select.thermostat_hc1_HP_Mode select.thermostat_hc1_hpmode
Rego 2000/3000 thermostat 172 dewoffset dew point offset uint8 (>=2<=10) K True number.thermostat_hc1_dew_point_offset number.thermostat_hc1_dewoffset
Rego 2000/3000 thermostat 172 roomtempdiff room temp difference uint8 (>=0<=254) K True number.thermostat_hc1_room_temp_difference number.thermostat_hc1_roomtempdiff
Rego 2000/3000 thermostat 172 hpminflowtemp HP min. flow temp. uint8 (>=0<=254) C True number.thermostat_hc1_HP_min._flow_temp. number.thermostat_hc1_hpminflowtemp
Rego 2000/3000 thermostat 172 control control device enum [RC310|RC200|RC100|RC100H|TC100] True select.thermostat_hc1_control_device select.thermostat_hc1_control
Rego 2000/3000 thermostat 172 remotetemp room temperature from remote int16 (>=-1<=101) C True number.thermostat_hc1_room_temperature_from_remote number.thermostat_hc1_remotetemp
Rego 2000/3000 thermostat 172 remotehum room humidity from remote uint8 (>=-1<=101) % True number.thermostat_hc1_room_humidity_from_remote number.thermostat_hc1_remotehum
Rego 2000/3000 thermostat 172 heatondelay heat-on delay uint8 (>=1<=48) hours True number.thermostat_hc1_heat-on_delay number.thermostat_hc1_heatondelay
Rego 2000/3000 thermostat 172 heatoffdelay heat-off delay uint8 (>=1<=48) hours True number.thermostat_hc1_heat-off_delay number.thermostat_hc1_heatoffdelay
Rego 2000/3000 thermostat 172 instantstart instant start uint8 (>=1<=10) K True number.thermostat_hc1_instant_start number.thermostat_hc1_instantstart
Rego 2000/3000 thermostat 172 boost boost mode boolean True switch.thermostat_hc1_boost_mode switch.thermostat_hc1_boost
Rego 2000/3000 thermostat 172 boosttime boost time uint8 (>=0<=254) hours True number.thermostat_hc1_boost_time number.thermostat_hc1_boosttime
Rego 2000/3000 thermostat 172 mode mode enum [normal|comfort|eco+] True select.thermostat_dhw_mode select.thermostat_dhw_mode
Rego 2000/3000 thermostat 172 settemp set temperature uint8 (>=0<=254) C True number.thermostat_dhw_set_temperature number.thermostat_dhw_settemp
Rego 2000/3000 thermostat 172 settemplow set low temperature uint8 (>=0<=254) C True number.thermostat_dhw_set_low_temperature number.thermostat_dhw_settemplow
Rego 2000/3000 thermostat 172 circmode circulation pump mode enum [off|on|auto|own prog] True select.thermostat_dhw_circulation_pump_mode select.thermostat_dhw_circmode
Rego 2000/3000 thermostat 172 chargeduration charge duration uint8 (>=0<=3810) minutes True number.thermostat_dhw_charge_duration number.thermostat_dhw_chargeduration
Rego 2000/3000 thermostat 172 charge charge boolean True switch.thermostat_dhw_charge switch.thermostat_dhw_charge
Rego 2000/3000 thermostat 172 extra extra uint8 (>=0<=254) C False sensor.thermostat_dhw_extra sensor.thermostat_dhw_extra
Rego 2000/3000 thermostat 172 disinfecting disinfecting boolean True switch.thermostat_dhw_disinfecting switch.thermostat_dhw_disinfecting
Rego 2000/3000 thermostat 172 disinfectday disinfection day enum [mo|tu|we|th|fr|sa|su|all] True select.thermostat_dhw_disinfection_day select.thermostat_dhw_disinfectday
Rego 2000/3000 thermostat 172 disinfecttime disinfection time uint8 (>=0<=1431) minutes True number.thermostat_dhw_disinfection_time number.thermostat_dhw_disinfecttime
Rego 2000/3000 thermostat 172 dailyheating daily heating boolean True switch.thermostat_dhw_daily_heating switch.thermostat_dhw_dailyheating
Rego 2000/3000 thermostat 172 dailyheattime daily heating time uint8 (>=0<=1431) minutes True number.thermostat_dhw_daily_heating_time number.thermostat_dhw_dailyheattime
Comfort RF thermostat 215 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode
Comfort RF thermostat 215 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode
Comfort RF thermostat 215 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime
Comfort RF thermostat 215 seltemp selected room temperature int16 (>=-15999<=15999) C False sensor.thermostat_hc1_selected_room_temperature sensor.thermostat_hc1_seltemp
Comfort RF thermostat 215 currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp
Comfort RF thermostat 215 haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate
Comfort RF thermostat 215 mode mode enum [auto|off] False sensor.thermostat_hc1_mode sensor.thermostat_hc1_mode
Comfort RF thermostat 215 modetype mode type enum [off|on] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype
Comfort RF thermostat 215 targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp
CRF200S thermostat 216 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode
CRF200S thermostat 216 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode
CRF200S thermostat 216 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime
CRF200S thermostat 216 seltemp selected room temperature int16 (>=-15999<=15999) C False sensor.thermostat_hc1_selected_room_temperature sensor.thermostat_hc1_seltemp
CRF200S thermostat 216 currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp
CRF200S thermostat 216 haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate
CRF200S thermostat 216 mode mode enum [auto|off] False sensor.thermostat_hc1_mode sensor.thermostat_hc1_mode
CRF200S thermostat 216 modetype mode type enum [off|on] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype
CRF200S thermostat 216 targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp
Comfort+2RF thermostat 246 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode
Comfort+2RF thermostat 246 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode
Comfort+2RF thermostat 246 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime
Comfort+2RF thermostat 246 seltemp selected room temperature int16 (>=-15999<=15999) C False sensor.thermostat_hc1_selected_room_temperature sensor.thermostat_hc1_seltemp
Comfort+2RF thermostat 246 currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp
Comfort+2RF thermostat 246 haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate
Comfort+2RF thermostat 246 mode mode enum [auto|off] False sensor.thermostat_hc1_mode sensor.thermostat_hc1_mode
Comfort+2RF thermostat 246 modetype mode type enum [off|on] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype
Comfort+2RF thermostat 246 targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp
Rego 3000/UI800/WSW196i/BC400 thermostat 253 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode
Rego 3000/UI800/WSW196i/BC400 thermostat 253 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode
Rego 3000/UI800/WSW196i/BC400 thermostat 253 datetime date/time string True sensor.thermostat_date/time sensor.thermostat_datetime
Rego 3000/UI800/WSW196i/BC400 thermostat 253 intoffset internal temperature offset int8 (>=-12<=12) C True number.thermostat_internal_temperature_offset number.thermostat_intoffset
Rego 3000/UI800/WSW196i/BC400 thermostat 253 floordry floor drying enum [off|start|heat|hold|cool|end] False sensor.thermostat_floor_drying sensor.thermostat_floordry
Rego 3000/UI800/WSW196i/BC400 thermostat 253 dampedoutdoortemp damped outdoor temperature int16 (>=-3199<=3199) C False sensor.thermostat_damped_outdoor_temperature sensor.thermostat_dampedoutdoortemp
Rego 3000/UI800/WSW196i/BC400 thermostat 253 floordrytemp floor drying temperature uint8 (>=0<=254) C False sensor.thermostat_floor_drying_temperature sensor.thermostat_floordrytemp
Rego 3000/UI800/WSW196i/BC400 thermostat 253 building building type enum [light|medium|heavy] True select.thermostat_building_type select.thermostat_building
Rego 3000/UI800/WSW196i/BC400 thermostat 253 minexttemp minimal external temperature int8 (>=-126<=126) C True number.thermostat_minimal_external_temperature number.thermostat_minexttemp
Rego 3000/UI800/WSW196i/BC400 thermostat 253 damping damping outdoor temperature boolean True switch.thermostat_damping_outdoor_temperature switch.thermostat_damping
Rego 3000/UI800/WSW196i/BC400 thermostat 253 hybridstrategy hybrid control strategy enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] True select.thermostat_hybrid_control_strategy select.thermostat_hybridstrategy
Rego 3000/UI800/WSW196i/BC400 thermostat 253 switchovertemp outside switchover temperature int8 (>=-20<=20) C True number.thermostat_outside_switchover_temperature number.thermostat_switchovertemp
Rego 3000/UI800/WSW196i/BC400 thermostat 253 energycostratio energy cost ratio uint8 (>=0<=20) True number.thermostat_energy_cost_ratio number.thermostat_energycostratio
Rego 3000/UI800/WSW196i/BC400 thermostat 253 fossilefactor fossile energy factor uint8 (>=0<=5) True number.thermostat_fossile_energy_factor number.thermostat_fossilefactor
Rego 3000/UI800/WSW196i/BC400 thermostat 253 electricfactor electric energy factor uint8 (>=0<=5) True number.thermostat_electric_energy_factor number.thermostat_electricfactor
Rego 3000/UI800/WSW196i/BC400 thermostat 253 delayboiler delay boiler support uint8 (>=5<=120) minutes True number.thermostat_delay_boiler_support number.thermostat_delayboiler
Rego 3000/UI800/WSW196i/BC400 thermostat 253 tempdiffboiler temp diff boiler support uint8 (>=1<=99) C True number.thermostat_temp_diff_boiler_support number.thermostat_tempdiffboiler
Rego 3000/UI800/WSW196i/BC400 thermostat 253 pvenabledhw enable raise dhw boolean True switch.thermostat_enable_raise_dhw switch.thermostat_pvenabledhw
Rego 3000/UI800/WSW196i/BC400 thermostat 253 pvraiseheat raise heating with PV int8 (>=0<=5) K True number.thermostat_raise_heating_with_PV number.thermostat_pvraiseheat
Rego 3000/UI800/WSW196i/BC400 thermostat 253 pvlowercool lower cooling with PV int8 (>=-5<=0) K True number.thermostat_lower_cooling_with_PV number.thermostat_pvlowercool
Rego 3000/UI800/WSW196i/BC400 thermostat 253 seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp
Rego 3000/UI800/WSW196i/BC400 thermostat 253 currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp
Rego 3000/UI800/WSW196i/BC400 thermostat 253 haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate
Rego 3000/UI800/WSW196i/BC400 thermostat 253 mode mode enum [off|manual|auto] True select.thermostat_hc1_mode select.thermostat_hc1_mode
Rego 3000/UI800/WSW196i/BC400 thermostat 253 modetype mode type enum [eco|comfort] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype
Rego 3000/UI800/WSW196i/BC400 thermostat 253 ecotemp eco temperature uint8 (>=0<=127) C True number.thermostat_hc1_eco_temperature number.thermostat_hc1_ecotemp
Rego 3000/UI800/WSW196i/BC400 thermostat 253 manualtemp manual temperature uint8 (>=0<=127) C True number.thermostat_hc1_manual_temperature number.thermostat_hc1_manualtemp
Rego 3000/UI800/WSW196i/BC400 thermostat 253 comforttemp comfort temperature uint8 (>=0<=127) C True number.thermostat_hc1_comfort_temperature number.thermostat_hc1_comforttemp
Rego 3000/UI800/WSW196i/BC400 thermostat 253 summertemp summer temperature uint8 (>=10<=30) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp
Rego 3000/UI800/WSW196i/BC400 thermostat 253 designtemp design temperature uint8 (>=0<=254) C True number.thermostat_hc1_design_temperature number.thermostat_hc1_designtemp
Rego 3000/UI800/WSW196i/BC400 thermostat 253 offsettemp offset temperature int8 (>=-126<=126) C True number.thermostat_hc1_offset_temperature number.thermostat_hc1_offsettemp
Rego 3000/UI800/WSW196i/BC400 thermostat 253 minflowtemp min flow temperature uint8 (>=0<=254) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp
Rego 3000/UI800/WSW196i/BC400 thermostat 253 maxflowtemp max flow temperature uint8 (>=0<=254) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp
Rego 3000/UI800/WSW196i/BC400 thermostat 253 roominfluence room influence uint8 (>=0<=254) C True number.thermostat_hc1_room_influence number.thermostat_hc1_roominfluence
Rego 3000/UI800/WSW196i/BC400 thermostat 253 roominflfactor room influence factor uint8 (>=0<=25) True number.thermostat_hc1_room_influence_factor number.thermostat_hc1_roominflfactor
Rego 3000/UI800/WSW196i/BC400 thermostat 253 curroominfl current room influence int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_influence sensor.thermostat_hc1_curroominfl
Rego 3000/UI800/WSW196i/BC400 thermostat 253 nofrostmode nofrost mode enum [room|outdoor|room outdoor] True select.thermostat_hc1_nofrost_mode select.thermostat_hc1_nofrostmode
Rego 3000/UI800/WSW196i/BC400 thermostat 253 nofrosttemp nofrost temperature int8 (>=-126<=126) C True number.thermostat_hc1_nofrost_temperature number.thermostat_hc1_nofrosttemp
Rego 3000/UI800/WSW196i/BC400 thermostat 253 targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp
Rego 3000/UI800/WSW196i/BC400 thermostat 253 heatingtype heating type enum [off|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype
Rego 3000/UI800/WSW196i/BC400 thermostat 253 summersetmode set summer mode enum [summer|auto|winter] True select.thermostat_hc1_set_summer_mode select.thermostat_hc1_summersetmode
Rego 3000/UI800/WSW196i/BC400 thermostat 253 hpoperatingmode heatpump operating mode enum [off|auto|heating|cooling] True select.thermostat_hc1_heatpump_operating_mode select.thermostat_hc1_hpoperatingmode
Rego 3000/UI800/WSW196i/BC400 thermostat 253 summermode summer mode enum [winter|summer] False sensor.thermostat_hc1_summer_mode sensor.thermostat_hc1_summermode
Rego 3000/UI800/WSW196i/BC400 thermostat 253 hpoperatingstate heatpump operating state enum [heating|off|cooling] False sensor.thermostat_hc1_heatpump_operating_state sensor.thermostat_hc1_hpoperatingstate
Rego 3000/UI800/WSW196i/BC400 thermostat 253 controlmode control mode enum [weather compensated|outside basepoint|n/a|room|power|constant] True select.thermostat_hc1_control_mode select.thermostat_hc1_controlmode
Rego 3000/UI800/WSW196i/BC400 thermostat 253 program program enum [prog 1|prog 2] True select.thermostat_hc1_program select.thermostat_hc1_program
Rego 3000/UI800/WSW196i/BC400 thermostat 253 tempautotemp temporary set temperature automode int8 (>=-1<=30) C True number.thermostat_hc1_temporary_set_temperature_automode number.thermostat_hc1_tempautotemp
Rego 3000/UI800/WSW196i/BC400 thermostat 253 remoteseltemp temporary set temperature from remote int8 (>=-63<=63) C False sensor.thermostat_hc1_temporary_set_temperature_from_remote sensor.thermostat_hc1_remoteseltemp
Rego 3000/UI800/WSW196i/BC400 thermostat 253 fastheatup fast heatup uint8 (>=0<=100) % True number.thermostat_hc1_fast_heatup number.thermostat_hc1_fastheatup
Rego 3000/UI800/WSW196i/BC400 thermostat 253 switchonoptimization switch-on optimization boolean True switch.thermostat_hc1_switch-on_optimization switch.thermostat_hc1_switchonoptimization
Rego 3000/UI800/WSW196i/BC400 thermostat 253 reducemode reduce mode enum [outdoor|room|reduce] True select.thermostat_hc1_reduce_mode select.thermostat_hc1_reducemode
Rego 3000/UI800/WSW196i/BC400 thermostat 253 noreducetemp no reduce below temperature int8 (>=-126<=126) C True number.thermostat_hc1_no_reduce_below_temperature number.thermostat_hc1_noreducetemp
Rego 3000/UI800/WSW196i/BC400 thermostat 253 reducetemp off/reduce switch temperature int8 (>=-126<=126) C True number.thermostat_hc1_off/reduce_switch_temperature number.thermostat_hc1_reducetemp
Rego 3000/UI800/WSW196i/BC400 thermostat 253 dhwprio dhw priority boolean True switch.thermostat_hc1_dhw_priority switch.thermostat_hc1_dhwprio
Rego 3000/UI800/WSW196i/BC400 thermostat 253 cooling cooling boolean True switch.thermostat_hc1_cooling switch.thermostat_hc1_cooling
Rego 3000/UI800/WSW196i/BC400 thermostat 253 coolingon cooling boolean False binary_sensor.thermostat_hc1_cooling binary_sensor.thermostat_hc1_coolingon
Rego 3000/UI800/WSW196i/BC400 thermostat 253 hpmode HP Mode enum [heating|cooling|heating&cooling] True select.thermostat_hc1_HP_Mode select.thermostat_hc1_hpmode
Rego 3000/UI800/WSW196i/BC400 thermostat 253 dewoffset dew point offset uint8 (>=2<=10) K True number.thermostat_hc1_dew_point_offset number.thermostat_hc1_dewoffset
Rego 3000/UI800/WSW196i/BC400 thermostat 253 roomtempdiff room temp difference uint8 (>=0<=254) K True number.thermostat_hc1_room_temp_difference number.thermostat_hc1_roomtempdiff
Rego 3000/UI800/WSW196i/BC400 thermostat 253 hpminflowtemp HP min. flow temp. uint8 (>=0<=254) C True number.thermostat_hc1_HP_min._flow_temp. number.thermostat_hc1_hpminflowtemp
Rego 3000/UI800/WSW196i/BC400 thermostat 253 control control device enum [RC310|RC200|RC100|RC100H|TC100] True select.thermostat_hc1_control_device select.thermostat_hc1_control
Rego 3000/UI800/WSW196i/BC400 thermostat 253 remotetemp room temperature from remote int16 (>=-1<=101) C True number.thermostat_hc1_room_temperature_from_remote number.thermostat_hc1_remotetemp
Rego 3000/UI800/WSW196i/BC400 thermostat 253 remotehum room humidity from remote uint8 (>=-1<=101) % True number.thermostat_hc1_room_humidity_from_remote number.thermostat_hc1_remotehum
Rego 3000/UI800/WSW196i/BC400 thermostat 253 heatondelay heat-on delay uint8 (>=1<=48) hours True number.thermostat_hc1_heat-on_delay number.thermostat_hc1_heatondelay
Rego 3000/UI800/WSW196i/BC400 thermostat 253 heatoffdelay heat-off delay uint8 (>=1<=48) hours True number.thermostat_hc1_heat-off_delay number.thermostat_hc1_heatoffdelay
Rego 3000/UI800/WSW196i/BC400 thermostat 253 instantstart instant start uint8 (>=1<=10) K True number.thermostat_hc1_instant_start number.thermostat_hc1_instantstart
Rego 3000/UI800/WSW196i/BC400 thermostat 253 boost boost mode boolean True switch.thermostat_hc1_boost_mode switch.thermostat_hc1_boost
Rego 3000/UI800/WSW196i/BC400 thermostat 253 boosttime boost time uint8 (>=0<=254) hours True number.thermostat_hc1_boost_time number.thermostat_hc1_boosttime
Rego 3000/UI800/WSW196i/BC400 thermostat 253 mode mode enum [off|eco+|eco|comfort|auto] True select.thermostat_dhw_mode select.thermostat_dhw_mode
Rego 3000/UI800/WSW196i/BC400 thermostat 253 settemp set temperature uint8 (>=0<=254) C True number.thermostat_dhw_set_temperature number.thermostat_dhw_settemp
Rego 3000/UI800/WSW196i/BC400 thermostat 253 settemplow set low temperature uint8 (>=0<=254) C True number.thermostat_dhw_set_low_temperature number.thermostat_dhw_settemplow
Rego 3000/UI800/WSW196i/BC400 thermostat 253 circmode circulation pump mode enum [off|on|auto|own prog] True select.thermostat_dhw_circulation_pump_mode select.thermostat_dhw_circmode
Rego 3000/UI800/WSW196i/BC400 thermostat 253 chargeduration charge duration uint8 (>=0<=3810) minutes True number.thermostat_dhw_charge_duration number.thermostat_dhw_chargeduration
Rego 3000/UI800/WSW196i/BC400 thermostat 253 charge charge boolean True switch.thermostat_dhw_charge switch.thermostat_dhw_charge
Rego 3000/UI800/WSW196i/BC400 thermostat 253 extra extra uint8 (>=0<=254) C False sensor.thermostat_dhw_extra sensor.thermostat_dhw_extra
Rego 3000/UI800/WSW196i/BC400 thermostat 253 disinfecting disinfecting boolean True switch.thermostat_dhw_disinfecting switch.thermostat_dhw_disinfecting
Rego 3000/UI800/WSW196i/BC400 thermostat 253 disinfectday disinfection day enum [mo|tu|we|th|fr|sa|su|all] True select.thermostat_dhw_disinfection_day select.thermostat_dhw_disinfectday
Rego 3000/UI800/WSW196i/BC400 thermostat 253 disinfecttime disinfection time uint8 (>=0<=1431) minutes True number.thermostat_dhw_disinfection_time number.thermostat_dhw_disinfecttime
Rego 3000/UI800/WSW196i/BC400 thermostat 253 dailyheating daily heating boolean True switch.thermostat_dhw_daily_heating switch.thermostat_dhw_dailyheating
Rego 3000/UI800/WSW196i/BC400 thermostat 253 dailyheattime daily heating time uint8 (>=0<=1431) minutes True number.thermostat_dhw_daily_heating_time number.thermostat_dhw_dailyheattime
ES72/RC20 thermostat 66 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode
ES72/RC20 thermostat 66 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode
ES72/RC20 thermostat 66 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime
ES72/RC20 thermostat 66 minexttemp minimal external temperature int8 (>=-126<=126) C True number.thermostat_minimal_external_temperature number.thermostat_minexttemp
ES72/RC20 thermostat 66 seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp
ES72/RC20 thermostat 66 currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp
ES72/RC20 thermostat 66 haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate
ES72/RC20 thermostat 66 mode mode enum [night|day|auto] True select.thermostat_hc1_mode select.thermostat_hc1_mode
ES72/RC20 thermostat 66 modetype mode type enum [night|day] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype
ES72/RC20 thermostat 66 daytemp day temperature uint8 (>=0<=127) C True number.thermostat_hc1_day_temperature number.thermostat_hc1_daytemp
ES72/RC20 thermostat 66 nighttemp night temperature uint8 (>=0<=127) C True number.thermostat_hc1_night_temperature number.thermostat_hc1_nighttemp
ES72/RC20 thermostat 66 program program enum [family|morning|evening|am|pm|midday|singles|seniors] True select.thermostat_hc1_program select.thermostat_hc1_program
ES72/RC20 thermostat 66 minflowtemp min flow temperature uint8 (>=0<=254) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp
ES72/RC20 thermostat 66 maxflowtemp max flow temperature uint8 (>=0<=254) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp
ES72/RC20 thermostat 66 tempautotemp temporary set temperature automode uint8 (>=0<=127) C True number.thermostat_hc1_temporary_set_temperature_automode number.thermostat_hc1_tempautotemp
ES72/RC20 thermostat 66 heatingtype heating type enum [off|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype
ES72/RC20 thermostat 66 summertemp summer temperature uint8 (>=10<=30) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp
ES72/RC20 thermostat 66 summermode summer mode enum [winter|summer] False sensor.thermostat_hc1_summer_mode sensor.thermostat_hc1_summermode
ES72/RC20 thermostat 66 remotetemp room temperature from remote int16 (>=-3199<=3199) C False sensor.thermostat_hc1_room_temperature_from_remote sensor.thermostat_hc1_remotetemp
ES73 thermostat 76 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode
ES73 thermostat 76 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode
ES73 thermostat 76 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime
ES73 thermostat 76 display display enum [internal temperature|internal setpoint|external temperature|burner temperature|dhw temperature|functioning mode|time|date|smoke temperature] True select.thermostat_display select.thermostat_display
ES73 thermostat 76 language language enum [german|dutch|french|italian] False sensor.thermostat_language sensor.thermostat_language
ES73 thermostat 76 clockoffset clock offset int8 (>=-126<=126) seconds True number.thermostat_clock_offset number.thermostat_clockoffset
ES73 thermostat 76 intoffset internal temperature offset int8 (>=-12<=12) C True number.thermostat_internal_temperature_offset number.thermostat_intoffset
ES73 thermostat 76 minexttemp minimal external temperature int8 (>=-126<=126) C True number.thermostat_minimal_external_temperature number.thermostat_minexttemp
ES73 thermostat 76 inttemp1 temperature sensor 1 int16 (>=-3199<=3199) C False sensor.thermostat_temperature_sensor_1 sensor.thermostat_inttemp1
ES73 thermostat 76 inttemp2 temperature sensor 2 int16 (>=-3199<=3199) C False sensor.thermostat_temperature_sensor_2 sensor.thermostat_inttemp2
ES73 thermostat 76 damping damping outdoor temperature boolean True switch.thermostat_damping_outdoor_temperature switch.thermostat_damping
ES73 thermostat 76 dampedoutdoortemp damped outdoor temperature int8 (>=-126<=126) C False sensor.thermostat_damped_outdoor_temperature sensor.thermostat_dampedoutdoortemp
ES73 thermostat 76 building building type enum [light|medium|heavy] True select.thermostat_building_type select.thermostat_building
ES73 thermostat 76 seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp
ES73 thermostat 76 currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp
ES73 thermostat 76 haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate
ES73 thermostat 76 mode mode enum [night|day|auto] True select.thermostat_hc1_mode select.thermostat_hc1_mode
ES73 thermostat 76 modetype mode type enum [night|day] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype
ES73 thermostat 76 daytemp day temperature uint8 (>=10<=30) C True number.thermostat_hc1_day_temperature number.thermostat_hc1_daytemp
ES73 thermostat 76 nighttemp night temperature uint8 (>=10<=30) C True number.thermostat_hc1_night_temperature number.thermostat_hc1_nighttemp
ES73 thermostat 76 designtemp design temperature uint8 (>=30<=90) C True number.thermostat_hc1_design_temperature number.thermostat_hc1_designtemp
ES73 thermostat 76 offsettemp offset temperature int8 (>=-5<=5) C True number.thermostat_hc1_offset_temperature number.thermostat_hc1_offsettemp
ES73 thermostat 76 holidaytemp holiday temperature uint8 (>=5<=30) C True number.thermostat_hc1_holiday_temperature number.thermostat_hc1_holidaytemp
ES73 thermostat 76 targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp
ES73 thermostat 76 summertemp summer temperature uint8 (>=9<=25) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp
ES73 thermostat 76 summermode summer mode enum [winter|summer] False sensor.thermostat_hc1_summer_mode sensor.thermostat_hc1_summermode
ES73 thermostat 76 holidaymode holiday mode boolean False binary_sensor.thermostat_hc1_holiday_mode binary_sensor.thermostat_hc1_holidaymode
ES73 thermostat 76 nofrosttemp nofrost temperature int8 (>=-20<=10) C True number.thermostat_hc1_nofrost_temperature number.thermostat_hc1_nofrosttemp
ES73 thermostat 76 nofrostmode nofrost mode enum [off|outdoor|room] True select.thermostat_hc1_nofrost_mode select.thermostat_hc1_nofrostmode
ES73 thermostat 76 roominfluence room influence uint8 (>=0<=10) C True number.thermostat_hc1_room_influence number.thermostat_hc1_roominfluence
ES73 thermostat 76 minflowtemp min flow temperature uint8 (>=5<=70) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp
ES73 thermostat 76 maxflowtemp max flow temperature uint8 (>=30<=90) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp
ES73 thermostat 76 flowtempoffset flow temperature offset for mixer uint8 (>=0<=20) C True number.thermostat_hc1_flow_temperature_offset_for_mixer number.thermostat_hc1_flowtempoffset
ES73 thermostat 76 heatingtype heating type enum [off|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype
ES73 thermostat 76 reducemode reduce mode enum [nofrost|reduce|room|outdoor] True select.thermostat_hc1_reduce_mode select.thermostat_hc1_reducemode
ES73 thermostat 76 controlmode control mode enum [outdoor|room] True select.thermostat_hc1_control_mode select.thermostat_hc1_controlmode
ES73 thermostat 76 control control device enum [off|RC20|RC3x] True select.thermostat_hc1_control_device select.thermostat_hc1_control
ES73 thermostat 76 holidays holiday dates string True sensor.thermostat_hc1_holiday_dates sensor.thermostat_hc1_holidays
ES73 thermostat 76 vacations vacation dates string True sensor.thermostat_hc1_vacation_dates sensor.thermostat_hc1_vacations
ES73 thermostat 76 program program enum [own 1|family|morning|evening|am|pm|midday|singles|seniors|new|own 2] True select.thermostat_hc1_program select.thermostat_hc1_program
ES73 thermostat 76 pause pause time uint8 (>=0<=99) hours True number.thermostat_hc1_pause_time number.thermostat_hc1_pause
ES73 thermostat 76 party party time uint8 (>=0<=99) hours True number.thermostat_hc1_party_time number.thermostat_hc1_party
ES73 thermostat 76 tempautotemp temporary set temperature automode uint8 (>=0<=30) C True number.thermostat_hc1_temporary_set_temperature_automode number.thermostat_hc1_tempautotemp
ES73 thermostat 76 noreducetemp no reduce below temperature int8 (>=-31<=10) C True number.thermostat_hc1_no_reduce_below_temperature number.thermostat_hc1_noreducetemp
ES73 thermostat 76 reducetemp off/reduce switch temperature int8 (>=-20<=10) C True number.thermostat_hc1_off/reduce_switch_temperature number.thermostat_hc1_reducetemp
ES73 thermostat 76 vacreducetemp vacations off/reduce switch temperature int8 (>=-20<=10) C True number.thermostat_hc1_vacations_off/reduce_switch_temperature number.thermostat_hc1_vacreducetemp
ES73 thermostat 76 vacreducemode vacations reduce mode enum [nofrost|reduce|room|outdoor] True select.thermostat_hc1_vacations_reduce_mode select.thermostat_hc1_vacreducemode
ES73 thermostat 76 remotetemp room temperature from remote int16 (>=-1<=101) C True number.thermostat_hc1_room_temperature_from_remote number.thermostat_hc1_remotetemp
ES73 thermostat 76 dhwprio dhw priority boolean True switch.thermostat_hc1_dhw_priority switch.thermostat_hc1_dhwprio
ES73 thermostat 76 switchonoptimization switch-on optimization boolean True switch.thermostat_hc1_switch-on_optimization switch.thermostat_hc1_switchonoptimization
ES73 thermostat 76 switchtime1 own1 program switchtime string True sensor.thermostat_hc1_own1_program_switchtime sensor.thermostat_hc1_switchtime1
ES73 thermostat 76 switchtime2 own2 program switchtime string True sensor.thermostat_hc1_own2_program_switchtime sensor.thermostat_hc1_switchtime2
ES73 thermostat 76 mode mode enum [off|on|auto] True select.thermostat_dhw_mode select.thermostat_dhw_mode
ES73 thermostat 76 circmode circulation pump mode enum [off|on|auto] True select.thermostat_dhw_circulation_pump_mode select.thermostat_dhw_circmode
ES73 thermostat 76 progmode program enum [std prog|own prog] True select.thermostat_dhw_program select.thermostat_dhw_progmode
ES73 thermostat 76 circprog circulation program enum [std prog|own prog] True select.thermostat_dhw_circulation_program select.thermostat_dhw_circprog
ES73 thermostat 76 disinfecting disinfecting boolean True switch.thermostat_dhw_disinfecting switch.thermostat_dhw_disinfecting
ES73 thermostat 76 disinfectday disinfection day enum [mo|tu|we|th|fr|sa|su|all] True select.thermostat_dhw_disinfection_day select.thermostat_dhw_disinfectday
ES73 thermostat 76 disinfecthour disinfection hour uint8 (>=0<=23) True number.thermostat_dhw_disinfection_hour number.thermostat_dhw_disinfecthour
ES73 thermostat 76 maxtemp maximum temperature uint8 (>=0<=254) C True number.thermostat_dhw_maximum_temperature number.thermostat_dhw_maxtemp
ES73 thermostat 76 onetimekey one time key function boolean True switch.thermostat_dhw_one_time_key_function switch.thermostat_dhw_onetimekey
ES73 thermostat 76 switchtime program switchtime string True sensor.thermostat_dhw_program_switchtime sensor.thermostat_dhw_switchtime
ES73 thermostat 76 circswitchtime circulation program switchtime string True sensor.thermostat_dhw_circulation_program_switchtime sensor.thermostat_dhw_circswitchtime
ES73 thermostat 76 holidays holiday dates string True sensor.thermostat_dhw_holiday_dates sensor.thermostat_dhw_holidays
ES73 thermostat 76 vacations vacation dates string True sensor.thermostat_dhw_vacation_dates sensor.thermostat_dhw_vacations
ES72/RC20 thermostat 113 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode
ES72/RC20 thermostat 113 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode
ES72/RC20 thermostat 113 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime
ES72/RC20 thermostat 113 minexttemp minimal external temperature int8 (>=-126<=126) C True number.thermostat_minimal_external_temperature number.thermostat_minexttemp
ES72/RC20 thermostat 113 seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp
ES72/RC20 thermostat 113 currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp
ES72/RC20 thermostat 113 haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate
ES72/RC20 thermostat 113 mode mode enum [night|day|auto] True select.thermostat_hc1_mode select.thermostat_hc1_mode
ES72/RC20 thermostat 113 modetype mode type enum [night|day] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype
ES72/RC20 thermostat 113 daytemp day temperature uint8 (>=0<=127) C True number.thermostat_hc1_day_temperature number.thermostat_hc1_daytemp
ES72/RC20 thermostat 113 nighttemp night temperature uint8 (>=0<=127) C True number.thermostat_hc1_night_temperature number.thermostat_hc1_nighttemp
ES72/RC20 thermostat 113 program program enum [family|morning|evening|am|pm|midday|singles|seniors] True select.thermostat_hc1_program select.thermostat_hc1_program
ES72/RC20 thermostat 113 minflowtemp min flow temperature uint8 (>=0<=254) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp
ES72/RC20 thermostat 113 maxflowtemp max flow temperature uint8 (>=0<=254) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp
ES72/RC20 thermostat 113 tempautotemp temporary set temperature automode uint8 (>=0<=127) C True number.thermostat_hc1_temporary_set_temperature_automode number.thermostat_hc1_tempautotemp
ES72/RC20 thermostat 113 heatingtype heating type enum [off|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype
ES72/RC20 thermostat 113 summertemp summer temperature uint8 (>=10<=30) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp
ES72/RC20 thermostat 113 summermode summer mode enum [winter|summer] False sensor.thermostat_hc1_summer_mode sensor.thermostat_hc1_summermode
ES72/RC20 thermostat 113 remotetemp room temperature from remote int16 (>=-3199<=3199) C False sensor.thermostat_hc1_room_temperature_from_remote sensor.thermostat_hc1_remotetemp
ES79 thermostat 156 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode
ES79 thermostat 156 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode
ES79 thermostat 156 datetime date/time string True sensor.thermostat_date/time sensor.thermostat_datetime
ES79 thermostat 156 intoffset internal temperature offset int8 (>=-5<=5) C True number.thermostat_internal_temperature_offset number.thermostat_intoffset
ES79 thermostat 156 minexttemp minimal external temperature int8 (>=-30<=0) C True number.thermostat_minimal_external_temperature number.thermostat_minexttemp
ES79 thermostat 156 inttemp1 temperature sensor 1 int16 (>=-3199<=3199) C False sensor.thermostat_temperature_sensor_1 sensor.thermostat_inttemp1
ES79 thermostat 156 inttemp2 temperature sensor 2 int16 (>=-3199<=3199) C False sensor.thermostat_temperature_sensor_2 sensor.thermostat_inttemp2
ES79 thermostat 156 damping damping outdoor temperature boolean True switch.thermostat_damping_outdoor_temperature switch.thermostat_damping
ES79 thermostat 156 dampedoutdoortemp damped outdoor temperature int8 (>=-126<=126) C False sensor.thermostat_damped_outdoor_temperature sensor.thermostat_dampedoutdoortemp
ES79 thermostat 156 building building type enum [light|medium|heavy] True select.thermostat_building_type select.thermostat_building
ES79 thermostat 156 seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp
ES79 thermostat 156 currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp
ES79 thermostat 156 haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate
ES79 thermostat 156 mode mode enum [night|day|auto] True select.thermostat_hc1_mode select.thermostat_hc1_mode
ES79 thermostat 156 modetype mode type enum [night|day] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype
ES79 thermostat 156 daytemp day temperature uint8 (>=10<=30) C True number.thermostat_hc1_day_temperature number.thermostat_hc1_daytemp
ES79 thermostat 156 nighttemp night temperature uint8 (>=10<=30) C True number.thermostat_hc1_night_temperature number.thermostat_hc1_nighttemp
ES79 thermostat 156 designtemp design temperature uint8 (>=30<=90) C True number.thermostat_hc1_design_temperature number.thermostat_hc1_designtemp
ES79 thermostat 156 offsettemp offset temperature int8 (>=-5<=5) C True number.thermostat_hc1_offset_temperature number.thermostat_hc1_offsettemp
ES79 thermostat 156 holidaytemp holiday temperature uint8 (>=5<=30) C True number.thermostat_hc1_holiday_temperature number.thermostat_hc1_holidaytemp
ES79 thermostat 156 targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp
ES79 thermostat 156 summertemp summer temperature uint8 (>=9<=25) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp
ES79 thermostat 156 summermode summer mode enum [winter|summer] False sensor.thermostat_hc1_summer_mode sensor.thermostat_hc1_summermode
ES79 thermostat 156 holidaymode holiday mode boolean False binary_sensor.thermostat_hc1_holiday_mode binary_sensor.thermostat_hc1_holidaymode
ES79 thermostat 156 nofrosttemp nofrost temperature int8 (>=-20<=10) C True number.thermostat_hc1_nofrost_temperature number.thermostat_hc1_nofrosttemp
ES79 thermostat 156 nofrostmode nofrost mode enum [off|outdoor|room] True select.thermostat_hc1_nofrost_mode select.thermostat_hc1_nofrostmode
ES79 thermostat 156 roominfluence room influence uint8 (>=0<=10) C True number.thermostat_hc1_room_influence number.thermostat_hc1_roominfluence
ES79 thermostat 156 minflowtemp min flow temperature uint8 (>=5<=70) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp
ES79 thermostat 156 maxflowtemp max flow temperature uint8 (>=30<=90) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp
ES79 thermostat 156 flowtempoffset flow temperature offset for mixer uint8 (>=0<=20) C True number.thermostat_hc1_flow_temperature_offset_for_mixer number.thermostat_hc1_flowtempoffset
ES79 thermostat 156 heatingtype heating type enum [off|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype
ES79 thermostat 156 reducemode reduce mode enum [nofrost|reduce|room|outdoor] True select.thermostat_hc1_reduce_mode select.thermostat_hc1_reducemode
ES79 thermostat 156 controlmode control mode enum [outdoor|room] True select.thermostat_hc1_control_mode select.thermostat_hc1_controlmode
ES79 thermostat 156 control control device enum [off|RC20|RC3x] True select.thermostat_hc1_control_device select.thermostat_hc1_control
ES79 thermostat 156 holidays holiday dates string True sensor.thermostat_hc1_holiday_dates sensor.thermostat_hc1_holidays
ES79 thermostat 156 vacations vacation dates string True sensor.thermostat_hc1_vacation_dates sensor.thermostat_hc1_vacations
ES79 thermostat 156 program program enum [own 1|family|morning|evening|am|pm|midday|singles|seniors|new|own 2] True select.thermostat_hc1_program select.thermostat_hc1_program
ES79 thermostat 156 pause pause time uint8 (>=0<=99) hours True number.thermostat_hc1_pause_time number.thermostat_hc1_pause
ES79 thermostat 156 party party time uint8 (>=0<=99) hours True number.thermostat_hc1_party_time number.thermostat_hc1_party
ES79 thermostat 156 tempautotemp temporary set temperature automode uint8 (>=0<=30) C True number.thermostat_hc1_temporary_set_temperature_automode number.thermostat_hc1_tempautotemp
ES79 thermostat 156 noreducetemp no reduce below temperature int8 (>=-31<=10) C True number.thermostat_hc1_no_reduce_below_temperature number.thermostat_hc1_noreducetemp
ES79 thermostat 156 reducetemp off/reduce switch temperature int8 (>=-20<=10) C True number.thermostat_hc1_off/reduce_switch_temperature number.thermostat_hc1_reducetemp
ES79 thermostat 156 vacreducetemp vacations off/reduce switch temperature int8 (>=-20<=10) C True number.thermostat_hc1_vacations_off/reduce_switch_temperature number.thermostat_hc1_vacreducetemp
ES79 thermostat 156 vacreducemode vacations reduce mode enum [nofrost|reduce|room|outdoor] True select.thermostat_hc1_vacations_reduce_mode select.thermostat_hc1_vacreducemode
ES79 thermostat 156 remotetemp room temperature from remote int16 (>=-1<=101) C True number.thermostat_hc1_room_temperature_from_remote number.thermostat_hc1_remotetemp
ES79 thermostat 156 dhwprio dhw priority boolean True switch.thermostat_hc1_dhw_priority switch.thermostat_hc1_dhwprio
ES79 thermostat 156 switchonoptimization switch-on optimization boolean True switch.thermostat_hc1_switch-on_optimization switch.thermostat_hc1_switchonoptimization
ES79 thermostat 156 switchtime1 own1 program switchtime string True sensor.thermostat_hc1_own1_program_switchtime sensor.thermostat_hc1_switchtime1
ES79 thermostat 156 switchtime2 own2 program switchtime string True sensor.thermostat_hc1_own2_program_switchtime sensor.thermostat_hc1_switchtime2
ES79 thermostat 156 mode mode enum [off|on|auto] True select.thermostat_dhw_mode select.thermostat_dhw_mode
ES79 thermostat 156 circmode circulation pump mode enum [off|on|auto] True select.thermostat_dhw_circulation_pump_mode select.thermostat_dhw_circmode
ES79 thermostat 156 progmode program enum [std prog|own prog] True select.thermostat_dhw_program select.thermostat_dhw_progmode
ES79 thermostat 156 circprog circulation program enum [std prog|own prog] True select.thermostat_dhw_circulation_program select.thermostat_dhw_circprog
ES79 thermostat 156 disinfecting disinfecting boolean True switch.thermostat_dhw_disinfecting switch.thermostat_dhw_disinfecting
ES79 thermostat 156 disinfectday disinfection day enum [mo|tu|we|th|fr|sa|su|all] True select.thermostat_dhw_disinfection_day select.thermostat_dhw_disinfectday
ES79 thermostat 156 disinfecthour disinfection hour uint8 (>=0<=23) True number.thermostat_dhw_disinfection_hour number.thermostat_dhw_disinfecthour
ES79 thermostat 156 maxtemp maximum temperature uint8 (>=60<=80) C True number.thermostat_dhw_maximum_temperature number.thermostat_dhw_maxtemp
ES79 thermostat 156 onetimekey one time key function boolean True switch.thermostat_dhw_one_time_key_function switch.thermostat_dhw_onetimekey
ES79 thermostat 156 switchtime program switchtime string True sensor.thermostat_dhw_program_switchtime sensor.thermostat_dhw_switchtime
ES79 thermostat 156 circswitchtime circulation program switchtime string True sensor.thermostat_dhw_circulation_program_switchtime sensor.thermostat_dhw_circswitchtime
ES79 thermostat 156 holidays holiday dates string True sensor.thermostat_dhw_holiday_dates sensor.thermostat_dhw_holidays
ES79 thermostat 156 vacations vacation dates string True sensor.thermostat_dhw_vacation_dates sensor.thermostat_dhw_vacations
FW100 thermostat 105 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode
FW100 thermostat 105 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode
FW100 thermostat 105 datetime date/time string True sensor.thermostat_date/time sensor.thermostat_datetime
FW100 thermostat 105 hybridstrategy hybrid control strategy enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] True select.thermostat_hybrid_control_strategy select.thermostat_hybridstrategy
FW100 thermostat 105 switchovertemp outside switchover temperature int8 (>=-20<=20) C True number.thermostat_outside_switchover_temperature number.thermostat_switchovertemp
FW100 thermostat 105 energycostratio energy cost ratio uint8 (>=0<=20) True number.thermostat_energy_cost_ratio number.thermostat_energycostratio
FW100 thermostat 105 fossilefactor fossile energy factor uint8 (>=0<=5) True number.thermostat_fossile_energy_factor number.thermostat_fossilefactor
FW100 thermostat 105 electricfactor electric energy factor uint8 (>=0<=5) True number.thermostat_electric_energy_factor number.thermostat_electricfactor
FW100 thermostat 105 delayboiler delay boiler support uint8 (>=5<=120) minutes True number.thermostat_delay_boiler_support number.thermostat_delayboiler
FW100 thermostat 105 tempdiffboiler temp diff boiler support uint8 (>=1<=99) C True number.thermostat_temp_diff_boiler_support number.thermostat_tempdiffboiler
FW100 thermostat 105 seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp
FW100 thermostat 105 currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp
FW100 thermostat 105 haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate
FW100 thermostat 105 mode mode enum [nofrost|eco|heat|auto] True select.thermostat_hc1_mode select.thermostat_hc1_mode
FW100 thermostat 105 modetype mode type enum [nofrost|eco|heat] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype
FW100 thermostat 105 heattemp heat temperature uint8 (>=0<=127) C True number.thermostat_hc1_heat_temperature number.thermostat_hc1_heattemp
FW100 thermostat 105 ecotemp eco temperature uint8 (>=0<=127) C True number.thermostat_hc1_eco_temperature number.thermostat_hc1_ecotemp
FW100 thermostat 105 nofrosttemp nofrost temperature int8 (>=-63<=63) C True number.thermostat_hc1_nofrost_temperature number.thermostat_hc1_nofrosttemp
FW100 thermostat 105 control control device enum [off|FB10|FB100] True select.thermostat_hc1_control_device select.thermostat_hc1_control
FW100 thermostat 105 program program enum [prog a|prog b|prog c|prog d|prog e|prog f] True select.thermostat_hc1_program select.thermostat_hc1_program
FW100 thermostat 105 remotetemp room temperature from remote int16 (>=-1<=101) C True number.thermostat_hc1_room_temperature_from_remote number.thermostat_hc1_remotetemp
FW100 thermostat 105 targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp
FW100 thermostat 105 summertemp summer temperature uint8 (>=9<=25) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp
FW100 thermostat 105 roomsensor room sensor enum [extern|intern|auto] True select.thermostat_hc1_room_sensor select.thermostat_hc1_roomsensor
FW100 thermostat 105 holidaymode holiday mode enum [nofrost|eco|heat|auto] True select.thermostat_hc1_holiday_mode select.thermostat_hc1_holidaymode
FW100 thermostat 105 switchonoptimization switch-on optimization boolean True switch.thermostat_hc1_switch-on_optimization switch.thermostat_hc1_switchonoptimization
FW100 thermostat 105 heatup heatup enum [slow|medium|fast] True select.thermostat_hc1_heatup select.thermostat_hc1_heatup
FW100 thermostat 105 minflowtemp min flow temperature uint8 (>=5<=70) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp
FW100 thermostat 105 maxflowtemp max flow temperature uint8 (>=30<=90) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp
FW100 thermostat 105 designtemp design temperature uint8 (>=30<=90) C True number.thermostat_hc1_design_temperature number.thermostat_hc1_designtemp
FW100 thermostat 105 roominfluence room influence enum [off|intern|extern|auto] True select.thermostat_hc1_room_influence select.thermostat_hc1_roominfluence
FW100 thermostat 105 roominflfactor room influence factor uint8 (>=0<=100) % True number.thermostat_hc1_room_influence_factor number.thermostat_hc1_roominflfactor
FW100 thermostat 105 heatingtype heating type enum [off|heatingcurve|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype
FW100 thermostat 105 controlmode control mode enum [off|unmixed|unmixed IPM|mixed IPM] True select.thermostat_hc1_control_mode select.thermostat_hc1_controlmode
FW100 thermostat 105 charge charge boolean True switch.thermostat_dhw_charge switch.thermostat_dhw_charge
FW200 thermostat 106 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode
FW200 thermostat 106 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode
FW200 thermostat 106 datetime date/time string True sensor.thermostat_date/time sensor.thermostat_datetime
FW200 thermostat 106 hybridstrategy hybrid control strategy enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] True select.thermostat_hybrid_control_strategy select.thermostat_hybridstrategy
FW200 thermostat 106 switchovertemp outside switchover temperature int8 (>=-20<=20) C True number.thermostat_outside_switchover_temperature number.thermostat_switchovertemp
FW200 thermostat 106 energycostratio energy cost ratio uint8 (>=0<=20) True number.thermostat_energy_cost_ratio number.thermostat_energycostratio
FW200 thermostat 106 fossilefactor fossile energy factor uint8 (>=0<=5) True number.thermostat_fossile_energy_factor number.thermostat_fossilefactor
FW200 thermostat 106 electricfactor electric energy factor uint8 (>=0<=5) True number.thermostat_electric_energy_factor number.thermostat_electricfactor
FW200 thermostat 106 delayboiler delay boiler support uint8 (>=5<=120) minutes True number.thermostat_delay_boiler_support number.thermostat_delayboiler
FW200 thermostat 106 tempdiffboiler temp diff boiler support uint8 (>=1<=99) C True number.thermostat_temp_diff_boiler_support number.thermostat_tempdiffboiler
FW200 thermostat 106 seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp
FW200 thermostat 106 currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp
FW200 thermostat 106 haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate
FW200 thermostat 106 mode mode enum [nofrost|eco|heat|auto] True select.thermostat_hc1_mode select.thermostat_hc1_mode
FW200 thermostat 106 modetype mode type enum [nofrost|eco|heat] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype
FW200 thermostat 106 heattemp heat temperature uint8 (>=0<=127) C True number.thermostat_hc1_heat_temperature number.thermostat_hc1_heattemp
FW200 thermostat 106 ecotemp eco temperature uint8 (>=0<=127) C True number.thermostat_hc1_eco_temperature number.thermostat_hc1_ecotemp
FW200 thermostat 106 nofrosttemp nofrost temperature int8 (>=-63<=63) C True number.thermostat_hc1_nofrost_temperature number.thermostat_hc1_nofrosttemp
FW200 thermostat 106 control control device enum [off|FB10|FB100] True select.thermostat_hc1_control_device select.thermostat_hc1_control
FW200 thermostat 106 program program enum [prog a|prog b|prog c|prog d|prog e|prog f] True select.thermostat_hc1_program select.thermostat_hc1_program
FW200 thermostat 106 remotetemp room temperature from remote int16 (>=-1<=101) C True number.thermostat_hc1_room_temperature_from_remote number.thermostat_hc1_remotetemp
FW200 thermostat 106 targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp
FW200 thermostat 106 summertemp summer temperature uint8 (>=9<=25) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp
FW200 thermostat 106 roomsensor room sensor enum [extern|intern|auto] True select.thermostat_hc1_room_sensor select.thermostat_hc1_roomsensor
FW200 thermostat 106 holidaymode holiday mode enum [nofrost|eco|heat|auto] True select.thermostat_hc1_holiday_mode select.thermostat_hc1_holidaymode
FW200 thermostat 106 switchonoptimization switch-on optimization boolean True switch.thermostat_hc1_switch-on_optimization switch.thermostat_hc1_switchonoptimization
FW200 thermostat 106 heatup heatup enum [slow|medium|fast] True select.thermostat_hc1_heatup select.thermostat_hc1_heatup
FW200 thermostat 106 minflowtemp min flow temperature uint8 (>=5<=70) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp
FW200 thermostat 106 maxflowtemp max flow temperature uint8 (>=30<=90) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp
FW200 thermostat 106 designtemp design temperature uint8 (>=30<=90) C True number.thermostat_hc1_design_temperature number.thermostat_hc1_designtemp
FW200 thermostat 106 roominfluence room influence enum [off|intern|extern|auto] True select.thermostat_hc1_room_influence select.thermostat_hc1_roominfluence
FW200 thermostat 106 roominflfactor room influence factor uint8 (>=0<=100) % True number.thermostat_hc1_room_influence_factor number.thermostat_hc1_roominflfactor
FW200 thermostat 106 heatingtype heating type enum [off|heatingcurve|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype
FW200 thermostat 106 controlmode control mode enum [off|unmixed|unmixed IPM|mixed IPM] True select.thermostat_hc1_control_mode select.thermostat_hc1_controlmode
FW200 thermostat 106 charge charge boolean True switch.thermostat_dhw_charge switch.thermostat_dhw_charge
FR100 thermostat 107 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode
FR100 thermostat 107 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode
FR100 thermostat 107 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime
FR100 thermostat 107 hybridstrategy hybrid control strategy enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] True select.thermostat_hybrid_control_strategy select.thermostat_hybridstrategy
FR100 thermostat 107 switchovertemp outside switchover temperature int8 (>=-20<=20) C True number.thermostat_outside_switchover_temperature number.thermostat_switchovertemp
FR100 thermostat 107 energycostratio energy cost ratio uint8 (>=0<=20) True number.thermostat_energy_cost_ratio number.thermostat_energycostratio
FR100 thermostat 107 fossilefactor fossile energy factor uint8 (>=0<=5) True number.thermostat_fossile_energy_factor number.thermostat_fossilefactor
FR100 thermostat 107 electricfactor electric energy factor uint8 (>=0<=5) True number.thermostat_electric_energy_factor number.thermostat_electricfactor
FR100 thermostat 107 delayboiler delay boiler support uint8 (>=5<=120) minutes True number.thermostat_delay_boiler_support number.thermostat_delayboiler
FR100 thermostat 107 tempdiffboiler temp diff boiler support uint8 (>=1<=99) C True number.thermostat_temp_diff_boiler_support number.thermostat_tempdiffboiler
FR100 thermostat 107 seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp
FR100 thermostat 107 currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp
FR100 thermostat 107 haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate
FR100 thermostat 107 mode mode enum [nofrost|eco|heat|auto] True select.thermostat_hc1_mode select.thermostat_hc1_mode
FR100 thermostat 107 modetype mode type enum [nofrost|eco|heat] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype
FR100 thermostat 107 heattemp heat temperature uint8 (>=0<=127) C True number.thermostat_hc1_heat_temperature number.thermostat_hc1_heattemp
FR100 thermostat 107 ecotemp eco temperature uint8 (>=0<=127) C True number.thermostat_hc1_eco_temperature number.thermostat_hc1_ecotemp
FR100 thermostat 107 nofrosttemp nofrost temperature int8 (>=-63<=63) C True number.thermostat_hc1_nofrost_temperature number.thermostat_hc1_nofrosttemp
FR100 thermostat 107 control control device enum [off|FB10|FB100] True select.thermostat_hc1_control_device select.thermostat_hc1_control
FR100 thermostat 107 program program enum [prog a|prog b|prog c|prog d|prog e|prog f] True select.thermostat_hc1_program select.thermostat_hc1_program
FR100 thermostat 107 remotetemp room temperature from remote int16 (>=-1<=101) C True number.thermostat_hc1_room_temperature_from_remote number.thermostat_hc1_remotetemp
FR100 thermostat 107 targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp
FR100 thermostat 107 summertemp summer temperature uint8 (>=9<=25) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp
FR100 thermostat 107 roomsensor room sensor enum [extern|intern|auto] True select.thermostat_hc1_room_sensor select.thermostat_hc1_roomsensor
FR100 thermostat 107 holidaymode holiday mode enum [nofrost|eco|heat|auto] True select.thermostat_hc1_holiday_mode select.thermostat_hc1_holidaymode
FR100 thermostat 107 switchonoptimization switch-on optimization boolean True switch.thermostat_hc1_switch-on_optimization switch.thermostat_hc1_switchonoptimization
FR100 thermostat 107 heatup heatup enum [slow|medium|fast] True select.thermostat_hc1_heatup select.thermostat_hc1_heatup
FR100 thermostat 107 minflowtemp min flow temperature uint8 (>=5<=70) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp
FR100 thermostat 107 maxflowtemp max flow temperature uint8 (>=30<=90) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp
FR100 thermostat 107 designtemp design temperature uint8 (>=30<=90) C True number.thermostat_hc1_design_temperature number.thermostat_hc1_designtemp
FR100 thermostat 107 roominfluence room influence enum [off|intern|extern|auto] True select.thermostat_hc1_room_influence select.thermostat_hc1_roominfluence
FR100 thermostat 107 roominflfactor room influence factor uint8 (>=0<=100) % True number.thermostat_hc1_room_influence_factor number.thermostat_hc1_roominflfactor
FR100 thermostat 107 heatingtype heating type enum [off|heatingcurve|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype
FR100 thermostat 107 controlmode control mode enum [off|unmixed|unmixed IPM|mixed IPM] True select.thermostat_hc1_control_mode select.thermostat_hc1_controlmode
FR100 thermostat 107 charge charge boolean True switch.thermostat_dhw_charge switch.thermostat_dhw_charge
FR110 thermostat 108 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode
FR110 thermostat 108 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode
FR110 thermostat 108 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime
FR110 thermostat 108 hybridstrategy hybrid control strategy enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] True select.thermostat_hybrid_control_strategy select.thermostat_hybridstrategy
FR110 thermostat 108 switchovertemp outside switchover temperature int8 (>=-20<=20) C True number.thermostat_outside_switchover_temperature number.thermostat_switchovertemp
FR110 thermostat 108 energycostratio energy cost ratio uint8 (>=0<=20) True number.thermostat_energy_cost_ratio number.thermostat_energycostratio
FR110 thermostat 108 fossilefactor fossile energy factor uint8 (>=0<=5) True number.thermostat_fossile_energy_factor number.thermostat_fossilefactor
FR110 thermostat 108 electricfactor electric energy factor uint8 (>=0<=5) True number.thermostat_electric_energy_factor number.thermostat_electricfactor
FR110 thermostat 108 delayboiler delay boiler support uint8 (>=5<=120) minutes True number.thermostat_delay_boiler_support number.thermostat_delayboiler
FR110 thermostat 108 tempdiffboiler temp diff boiler support uint8 (>=1<=99) C True number.thermostat_temp_diff_boiler_support number.thermostat_tempdiffboiler
FR110 thermostat 108 seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp
FR110 thermostat 108 currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp
FR110 thermostat 108 haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate
FR110 thermostat 108 mode mode enum [nofrost|eco|heat|auto] True select.thermostat_hc1_mode select.thermostat_hc1_mode
FR110 thermostat 108 modetype mode type enum [nofrost|eco|heat] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype
FR110 thermostat 108 heattemp heat temperature uint8 (>=0<=127) C True number.thermostat_hc1_heat_temperature number.thermostat_hc1_heattemp
FR110 thermostat 108 ecotemp eco temperature uint8 (>=0<=127) C True number.thermostat_hc1_eco_temperature number.thermostat_hc1_ecotemp
FR110 thermostat 108 nofrosttemp nofrost temperature int8 (>=-63<=63) C True number.thermostat_hc1_nofrost_temperature number.thermostat_hc1_nofrosttemp
FR110 thermostat 108 control control device enum [off|FB10|FB100] True select.thermostat_hc1_control_device select.thermostat_hc1_control
FR110 thermostat 108 program program enum [prog a|prog b|prog c|prog d|prog e|prog f] True select.thermostat_hc1_program select.thermostat_hc1_program
FR110 thermostat 108 remotetemp room temperature from remote int16 (>=-1<=101) C True number.thermostat_hc1_room_temperature_from_remote number.thermostat_hc1_remotetemp
FR110 thermostat 108 targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp
FR110 thermostat 108 summertemp summer temperature uint8 (>=9<=25) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp
FR110 thermostat 108 roomsensor room sensor enum [extern|intern|auto] True select.thermostat_hc1_room_sensor select.thermostat_hc1_roomsensor
FR110 thermostat 108 holidaymode holiday mode enum [nofrost|eco|heat|auto] True select.thermostat_hc1_holiday_mode select.thermostat_hc1_holidaymode
FR110 thermostat 108 switchonoptimization switch-on optimization boolean True switch.thermostat_hc1_switch-on_optimization switch.thermostat_hc1_switchonoptimization
FR110 thermostat 108 heatup heatup enum [slow|medium|fast] True select.thermostat_hc1_heatup select.thermostat_hc1_heatup
FR110 thermostat 108 minflowtemp min flow temperature uint8 (>=5<=70) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp
FR110 thermostat 108 maxflowtemp max flow temperature uint8 (>=30<=90) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp
FR110 thermostat 108 designtemp design temperature uint8 (>=30<=90) C True number.thermostat_hc1_design_temperature number.thermostat_hc1_designtemp
FR110 thermostat 108 roominfluence room influence enum [off|intern|extern|auto] True select.thermostat_hc1_room_influence select.thermostat_hc1_roominfluence
FR110 thermostat 108 roominflfactor room influence factor uint8 (>=0<=100) % True number.thermostat_hc1_room_influence_factor number.thermostat_hc1_roominflfactor
FR110 thermostat 108 heatingtype heating type enum [off|heatingcurve|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype
FR110 thermostat 108 controlmode control mode enum [off|unmixed|unmixed IPM|mixed IPM] True select.thermostat_hc1_control_mode select.thermostat_hc1_controlmode
FR110 thermostat 108 charge charge boolean True switch.thermostat_dhw_charge switch.thermostat_dhw_charge
FB10 thermostat 109 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode
FB10 thermostat 109 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode
FB10 thermostat 109 datetime date/time string True sensor.thermostat_date/time sensor.thermostat_datetime
FB10 thermostat 109 hybridstrategy hybrid control strategy enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] True select.thermostat_hybrid_control_strategy select.thermostat_hybridstrategy
FB10 thermostat 109 switchovertemp outside switchover temperature int8 (>=-20<=20) C True number.thermostat_outside_switchover_temperature number.thermostat_switchovertemp
FB10 thermostat 109 energycostratio energy cost ratio uint8 (>=0<=20) True number.thermostat_energy_cost_ratio number.thermostat_energycostratio
FB10 thermostat 109 fossilefactor fossile energy factor uint8 (>=0<=5) True number.thermostat_fossile_energy_factor number.thermostat_fossilefactor
FB10 thermostat 109 electricfactor electric energy factor uint8 (>=0<=5) True number.thermostat_electric_energy_factor number.thermostat_electricfactor
FB10 thermostat 109 delayboiler delay boiler support uint8 (>=5<=120) minutes True number.thermostat_delay_boiler_support number.thermostat_delayboiler
FB10 thermostat 109 tempdiffboiler temp diff boiler support uint8 (>=1<=99) C True number.thermostat_temp_diff_boiler_support number.thermostat_tempdiffboiler
FB10 thermostat 109 seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp
FB10 thermostat 109 currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp
FB10 thermostat 109 haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate
FB10 thermostat 109 mode mode enum [nofrost|eco|heat|auto] True select.thermostat_hc1_mode select.thermostat_hc1_mode
FB10 thermostat 109 modetype mode type enum [nofrost|eco|heat] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype
FB10 thermostat 109 heattemp heat temperature uint8 (>=0<=127) C True number.thermostat_hc1_heat_temperature number.thermostat_hc1_heattemp
FB10 thermostat 109 ecotemp eco temperature uint8 (>=0<=127) C True number.thermostat_hc1_eco_temperature number.thermostat_hc1_ecotemp
FB10 thermostat 109 nofrosttemp nofrost temperature int8 (>=-63<=63) C True number.thermostat_hc1_nofrost_temperature number.thermostat_hc1_nofrosttemp
FB10 thermostat 109 control control device enum [off|FB10|FB100] True select.thermostat_hc1_control_device select.thermostat_hc1_control
FB10 thermostat 109 program program enum [prog a|prog b|prog c|prog d|prog e|prog f] True select.thermostat_hc1_program select.thermostat_hc1_program
FB10 thermostat 109 remotetemp room temperature from remote int16 (>=-1<=101) C True number.thermostat_hc1_room_temperature_from_remote number.thermostat_hc1_remotetemp
FB10 thermostat 109 targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp
FB10 thermostat 109 summertemp summer temperature uint8 (>=9<=25) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp
FB10 thermostat 109 roomsensor room sensor enum [extern|intern|auto] True select.thermostat_hc1_room_sensor select.thermostat_hc1_roomsensor
FB10 thermostat 109 holidaymode holiday mode enum [nofrost|eco|heat|auto] True select.thermostat_hc1_holiday_mode select.thermostat_hc1_holidaymode
FB10 thermostat 109 switchonoptimization switch-on optimization boolean True switch.thermostat_hc1_switch-on_optimization switch.thermostat_hc1_switchonoptimization
FB10 thermostat 109 heatup heatup enum [slow|medium|fast] True select.thermostat_hc1_heatup select.thermostat_hc1_heatup
FB10 thermostat 109 minflowtemp min flow temperature uint8 (>=5<=70) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp
FB10 thermostat 109 maxflowtemp max flow temperature uint8 (>=30<=90) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp
FB10 thermostat 109 designtemp design temperature uint8 (>=30<=90) C True number.thermostat_hc1_design_temperature number.thermostat_hc1_designtemp
FB10 thermostat 109 roominfluence room influence enum [off|intern|extern|auto] True select.thermostat_hc1_room_influence select.thermostat_hc1_roominfluence
FB10 thermostat 109 roominflfactor room influence factor uint8 (>=0<=100) % True number.thermostat_hc1_room_influence_factor number.thermostat_hc1_roominflfactor
FB10 thermostat 109 heatingtype heating type enum [off|heatingcurve|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype
FB10 thermostat 109 controlmode control mode enum [off|unmixed|unmixed IPM|mixed IPM] True select.thermostat_hc1_control_mode select.thermostat_hc1_controlmode
FB10 thermostat 109 charge charge boolean True switch.thermostat_dhw_charge switch.thermostat_dhw_charge
FB100 thermostat 110 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode
FB100 thermostat 110 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode
FB100 thermostat 110 datetime date/time string True sensor.thermostat_date/time sensor.thermostat_datetime
FB100 thermostat 110 hybridstrategy hybrid control strategy enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] True select.thermostat_hybrid_control_strategy select.thermostat_hybridstrategy
FB100 thermostat 110 switchovertemp outside switchover temperature int8 (>=-20<=20) C True number.thermostat_outside_switchover_temperature number.thermostat_switchovertemp
FB100 thermostat 110 energycostratio energy cost ratio uint8 (>=0<=20) True number.thermostat_energy_cost_ratio number.thermostat_energycostratio
FB100 thermostat 110 fossilefactor fossile energy factor uint8 (>=0<=5) True number.thermostat_fossile_energy_factor number.thermostat_fossilefactor
FB100 thermostat 110 electricfactor electric energy factor uint8 (>=0<=5) True number.thermostat_electric_energy_factor number.thermostat_electricfactor
FB100 thermostat 110 delayboiler delay boiler support uint8 (>=5<=120) minutes True number.thermostat_delay_boiler_support number.thermostat_delayboiler
FB100 thermostat 110 tempdiffboiler temp diff boiler support uint8 (>=1<=99) C True number.thermostat_temp_diff_boiler_support number.thermostat_tempdiffboiler
FB100 thermostat 110 seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp
FB100 thermostat 110 currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp
FB100 thermostat 110 haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate
FB100 thermostat 110 mode mode enum [nofrost|eco|heat|auto] True select.thermostat_hc1_mode select.thermostat_hc1_mode
FB100 thermostat 110 modetype mode type enum [nofrost|eco|heat] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype
FB100 thermostat 110 heattemp heat temperature uint8 (>=0<=127) C True number.thermostat_hc1_heat_temperature number.thermostat_hc1_heattemp
FB100 thermostat 110 ecotemp eco temperature uint8 (>=0<=127) C True number.thermostat_hc1_eco_temperature number.thermostat_hc1_ecotemp
FB100 thermostat 110 nofrosttemp nofrost temperature int8 (>=-63<=63) C True number.thermostat_hc1_nofrost_temperature number.thermostat_hc1_nofrosttemp
FB100 thermostat 110 control control device enum [off|FB10|FB100] True select.thermostat_hc1_control_device select.thermostat_hc1_control
FB100 thermostat 110 program program enum [prog a|prog b|prog c|prog d|prog e|prog f] True select.thermostat_hc1_program select.thermostat_hc1_program
FB100 thermostat 110 remotetemp room temperature from remote int16 (>=-1<=101) C True number.thermostat_hc1_room_temperature_from_remote number.thermostat_hc1_remotetemp
FB100 thermostat 110 targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp
FB100 thermostat 110 summertemp summer temperature uint8 (>=9<=25) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp
FB100 thermostat 110 roomsensor room sensor enum [extern|intern|auto] True select.thermostat_hc1_room_sensor select.thermostat_hc1_roomsensor
FB100 thermostat 110 holidaymode holiday mode enum [nofrost|eco|heat|auto] True select.thermostat_hc1_holiday_mode select.thermostat_hc1_holidaymode
FB100 thermostat 110 switchonoptimization switch-on optimization boolean True switch.thermostat_hc1_switch-on_optimization switch.thermostat_hc1_switchonoptimization
FB100 thermostat 110 heatup heatup enum [slow|medium|fast] True select.thermostat_hc1_heatup select.thermostat_hc1_heatup
FB100 thermostat 110 minflowtemp min flow temperature uint8 (>=5<=70) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp
FB100 thermostat 110 maxflowtemp max flow temperature uint8 (>=30<=90) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp
FB100 thermostat 110 designtemp design temperature uint8 (>=30<=90) C True number.thermostat_hc1_design_temperature number.thermostat_hc1_designtemp
FB100 thermostat 110 roominfluence room influence enum [off|intern|extern|auto] True select.thermostat_hc1_room_influence select.thermostat_hc1_roominfluence
FB100 thermostat 110 roominflfactor room influence factor uint8 (>=0<=100) % True number.thermostat_hc1_room_influence_factor number.thermostat_hc1_roominflfactor
FB100 thermostat 110 heatingtype heating type enum [off|heatingcurve|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype
FB100 thermostat 110 controlmode control mode enum [off|unmixed|unmixed IPM|mixed IPM] True select.thermostat_hc1_control_mode select.thermostat_hc1_controlmode
FB100 thermostat 110 charge charge boolean True switch.thermostat_dhw_charge switch.thermostat_dhw_charge
FR10 thermostat 111 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode
FR10 thermostat 111 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode
FR10 thermostat 111 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime
FR10 thermostat 111 hybridstrategy hybrid control strategy enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] True select.thermostat_hybrid_control_strategy select.thermostat_hybridstrategy
FR10 thermostat 111 switchovertemp outside switchover temperature int8 (>=-20<=20) C True number.thermostat_outside_switchover_temperature number.thermostat_switchovertemp
FR10 thermostat 111 energycostratio energy cost ratio uint8 (>=0<=20) True number.thermostat_energy_cost_ratio number.thermostat_energycostratio
FR10 thermostat 111 fossilefactor fossile energy factor uint8 (>=0<=5) True number.thermostat_fossile_energy_factor number.thermostat_fossilefactor
FR10 thermostat 111 electricfactor electric energy factor uint8 (>=0<=5) True number.thermostat_electric_energy_factor number.thermostat_electricfactor
FR10 thermostat 111 delayboiler delay boiler support uint8 (>=5<=120) minutes True number.thermostat_delay_boiler_support number.thermostat_delayboiler
FR10 thermostat 111 tempdiffboiler temp diff boiler support uint8 (>=1<=99) C True number.thermostat_temp_diff_boiler_support number.thermostat_tempdiffboiler
FR10 thermostat 111 seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp
FR10 thermostat 111 currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp
FR10 thermostat 111 haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate
FR10 thermostat 111 mode mode enum [nofrost|eco|heat|auto] True select.thermostat_hc1_mode select.thermostat_hc1_mode
FR10 thermostat 111 modetype mode type enum [nofrost|eco|heat] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype
FR10 thermostat 111 heattemp heat temperature uint8 (>=0<=127) C True number.thermostat_hc1_heat_temperature number.thermostat_hc1_heattemp
FR10 thermostat 111 ecotemp eco temperature uint8 (>=0<=127) C True number.thermostat_hc1_eco_temperature number.thermostat_hc1_ecotemp
FR10 thermostat 111 nofrosttemp nofrost temperature int8 (>=-63<=63) C True number.thermostat_hc1_nofrost_temperature number.thermostat_hc1_nofrosttemp
FR10 thermostat 111 control control device enum [off|FB10|FB100] True select.thermostat_hc1_control_device select.thermostat_hc1_control
FR10 thermostat 111 program program enum [prog a|prog b|prog c|prog d|prog e|prog f] True select.thermostat_hc1_program select.thermostat_hc1_program
FR10 thermostat 111 remotetemp room temperature from remote int16 (>=-1<=101) C True number.thermostat_hc1_room_temperature_from_remote number.thermostat_hc1_remotetemp
FR10 thermostat 111 targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp
FR10 thermostat 111 summertemp summer temperature uint8 (>=9<=25) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp
FR10 thermostat 111 roomsensor room sensor enum [extern|intern|auto] True select.thermostat_hc1_room_sensor select.thermostat_hc1_roomsensor
FR10 thermostat 111 holidaymode holiday mode enum [nofrost|eco|heat|auto] True select.thermostat_hc1_holiday_mode select.thermostat_hc1_holidaymode
FR10 thermostat 111 switchonoptimization switch-on optimization boolean True switch.thermostat_hc1_switch-on_optimization switch.thermostat_hc1_switchonoptimization
FR10 thermostat 111 heatup heatup enum [slow|medium|fast] True select.thermostat_hc1_heatup select.thermostat_hc1_heatup
FR10 thermostat 111 minflowtemp min flow temperature uint8 (>=5<=70) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp
FR10 thermostat 111 maxflowtemp max flow temperature uint8 (>=30<=90) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp
FR10 thermostat 111 designtemp design temperature uint8 (>=30<=90) C True number.thermostat_hc1_design_temperature number.thermostat_hc1_designtemp
FR10 thermostat 111 roominfluence room influence enum [off|intern|extern|auto] True select.thermostat_hc1_room_influence select.thermostat_hc1_roominfluence
FR10 thermostat 111 roominflfactor room influence factor uint8 (>=0<=100) % True number.thermostat_hc1_room_influence_factor number.thermostat_hc1_roominflfactor
FR10 thermostat 111 heatingtype heating type enum [off|heatingcurve|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype
FR10 thermostat 111 controlmode control mode enum [off|unmixed|unmixed IPM|mixed IPM] True select.thermostat_hc1_control_mode select.thermostat_hc1_controlmode
FR10 thermostat 111 charge charge boolean True switch.thermostat_dhw_charge switch.thermostat_dhw_charge
FW500 thermostat 116 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode
FW500 thermostat 116 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode
FW500 thermostat 116 datetime date/time string True sensor.thermostat_date/time sensor.thermostat_datetime
FW500 thermostat 116 hybridstrategy hybrid control strategy enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] True select.thermostat_hybrid_control_strategy select.thermostat_hybridstrategy
FW500 thermostat 116 switchovertemp outside switchover temperature int8 (>=-20<=20) C True number.thermostat_outside_switchover_temperature number.thermostat_switchovertemp
FW500 thermostat 116 energycostratio energy cost ratio uint8 (>=0<=20) True number.thermostat_energy_cost_ratio number.thermostat_energycostratio
FW500 thermostat 116 fossilefactor fossile energy factor uint8 (>=0<=5) True number.thermostat_fossile_energy_factor number.thermostat_fossilefactor
FW500 thermostat 116 electricfactor electric energy factor uint8 (>=0<=5) True number.thermostat_electric_energy_factor number.thermostat_electricfactor
FW500 thermostat 116 delayboiler delay boiler support uint8 (>=5<=120) minutes True number.thermostat_delay_boiler_support number.thermostat_delayboiler
FW500 thermostat 116 tempdiffboiler temp diff boiler support uint8 (>=1<=99) C True number.thermostat_temp_diff_boiler_support number.thermostat_tempdiffboiler
FW500 thermostat 116 seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp
FW500 thermostat 116 currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp
FW500 thermostat 116 haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate
FW500 thermostat 116 mode mode enum [nofrost|eco|heat|auto] True select.thermostat_hc1_mode select.thermostat_hc1_mode
FW500 thermostat 116 modetype mode type enum [nofrost|eco|heat] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype
FW500 thermostat 116 heattemp heat temperature uint8 (>=0<=127) C True number.thermostat_hc1_heat_temperature number.thermostat_hc1_heattemp
FW500 thermostat 116 ecotemp eco temperature uint8 (>=0<=127) C True number.thermostat_hc1_eco_temperature number.thermostat_hc1_ecotemp
FW500 thermostat 116 nofrosttemp nofrost temperature int8 (>=-63<=63) C True number.thermostat_hc1_nofrost_temperature number.thermostat_hc1_nofrosttemp
FW500 thermostat 116 control control device enum [off|FB10|FB100] True select.thermostat_hc1_control_device select.thermostat_hc1_control
FW500 thermostat 116 program program enum [prog a|prog b|prog c|prog d|prog e|prog f] True select.thermostat_hc1_program select.thermostat_hc1_program
FW500 thermostat 116 remotetemp room temperature from remote int16 (>=-1<=101) C True number.thermostat_hc1_room_temperature_from_remote number.thermostat_hc1_remotetemp
FW500 thermostat 116 targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp
FW500 thermostat 116 summertemp summer temperature uint8 (>=9<=25) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp
FW500 thermostat 116 roomsensor room sensor enum [extern|intern|auto] True select.thermostat_hc1_room_sensor select.thermostat_hc1_roomsensor
FW500 thermostat 116 holidaymode holiday mode enum [nofrost|eco|heat|auto] True select.thermostat_hc1_holiday_mode select.thermostat_hc1_holidaymode
FW500 thermostat 116 switchonoptimization switch-on optimization boolean True switch.thermostat_hc1_switch-on_optimization switch.thermostat_hc1_switchonoptimization
FW500 thermostat 116 heatup heatup enum [slow|medium|fast] True select.thermostat_hc1_heatup select.thermostat_hc1_heatup
FW500 thermostat 116 minflowtemp min flow temperature uint8 (>=5<=70) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp
FW500 thermostat 116 maxflowtemp max flow temperature uint8 (>=30<=90) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp
FW500 thermostat 116 designtemp design temperature uint8 (>=30<=90) C True number.thermostat_hc1_design_temperature number.thermostat_hc1_designtemp
FW500 thermostat 116 roominfluence room influence enum [off|intern|extern|auto] True select.thermostat_hc1_room_influence select.thermostat_hc1_roominfluence
FW500 thermostat 116 roominflfactor room influence factor uint8 (>=0<=100) % True number.thermostat_hc1_room_influence_factor number.thermostat_hc1_roominflfactor
FW500 thermostat 116 heatingtype heating type enum [off|heatingcurve|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype
FW500 thermostat 116 controlmode control mode enum [off|unmixed|unmixed IPM|mixed IPM] True select.thermostat_hc1_control_mode select.thermostat_hc1_controlmode
FW500 thermostat 116 charge charge boolean True switch.thermostat_dhw_charge switch.thermostat_dhw_charge
FR50 thermostat 147 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode
FR50 thermostat 147 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode
FR50 thermostat 147 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime
FR50 thermostat 147 hybridstrategy hybrid control strategy enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] True select.thermostat_hybrid_control_strategy select.thermostat_hybridstrategy
FR50 thermostat 147 switchovertemp outside switchover temperature int8 (>=-20<=20) C True number.thermostat_outside_switchover_temperature number.thermostat_switchovertemp
FR50 thermostat 147 energycostratio energy cost ratio uint8 (>=0<=20) True number.thermostat_energy_cost_ratio number.thermostat_energycostratio
FR50 thermostat 147 fossilefactor fossile energy factor uint8 (>=0<=5) True number.thermostat_fossile_energy_factor number.thermostat_fossilefactor
FR50 thermostat 147 electricfactor electric energy factor uint8 (>=0<=5) True number.thermostat_electric_energy_factor number.thermostat_electricfactor
FR50 thermostat 147 delayboiler delay boiler support uint8 (>=5<=120) minutes True number.thermostat_delay_boiler_support number.thermostat_delayboiler
FR50 thermostat 147 tempdiffboiler temp diff boiler support uint8 (>=1<=99) C True number.thermostat_temp_diff_boiler_support number.thermostat_tempdiffboiler
FR50 thermostat 147 seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp
FR50 thermostat 147 currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp
FR50 thermostat 147 haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate
FR50 thermostat 147 mode mode enum [nofrost|eco|heat|auto] True select.thermostat_hc1_mode select.thermostat_hc1_mode
FR50 thermostat 147 modetype mode type enum [nofrost|eco|heat] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype
FR50 thermostat 147 heattemp heat temperature uint8 (>=0<=127) C True number.thermostat_hc1_heat_temperature number.thermostat_hc1_heattemp
FR50 thermostat 147 ecotemp eco temperature uint8 (>=0<=127) C True number.thermostat_hc1_eco_temperature number.thermostat_hc1_ecotemp
FR50 thermostat 147 nofrosttemp nofrost temperature int8 (>=-63<=63) C True number.thermostat_hc1_nofrost_temperature number.thermostat_hc1_nofrosttemp
FR50 thermostat 147 control control device enum [off|FB10|FB100] True select.thermostat_hc1_control_device select.thermostat_hc1_control
FR50 thermostat 147 program program enum [prog a|prog b|prog c|prog d|prog e|prog f] True select.thermostat_hc1_program select.thermostat_hc1_program
FR50 thermostat 147 remotetemp room temperature from remote int16 (>=-1<=101) C True number.thermostat_hc1_room_temperature_from_remote number.thermostat_hc1_remotetemp
FR50 thermostat 147 targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp
FR50 thermostat 147 summertemp summer temperature uint8 (>=9<=25) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp
FR50 thermostat 147 roomsensor room sensor enum [extern|intern|auto] True select.thermostat_hc1_room_sensor select.thermostat_hc1_roomsensor
FR50 thermostat 147 holidaymode holiday mode enum [nofrost|eco|heat|auto] True select.thermostat_hc1_holiday_mode select.thermostat_hc1_holidaymode
FR50 thermostat 147 switchonoptimization switch-on optimization boolean True switch.thermostat_hc1_switch-on_optimization switch.thermostat_hc1_switchonoptimization
FR50 thermostat 147 heatup heatup enum [slow|medium|fast] True select.thermostat_hc1_heatup select.thermostat_hc1_heatup
FR50 thermostat 147 minflowtemp min flow temperature uint8 (>=5<=70) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp
FR50 thermostat 147 maxflowtemp max flow temperature uint8 (>=30<=90) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp
FR50 thermostat 147 designtemp design temperature uint8 (>=30<=90) C True number.thermostat_hc1_design_temperature number.thermostat_hc1_designtemp
FR50 thermostat 147 roominfluence room influence enum [off|intern|extern|auto] True select.thermostat_hc1_room_influence select.thermostat_hc1_roominfluence
FR50 thermostat 147 roominflfactor room influence factor uint8 (>=0<=100) % True number.thermostat_hc1_room_influence_factor number.thermostat_hc1_roominflfactor
FR50 thermostat 147 heatingtype heating type enum [off|heatingcurve|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype
FR50 thermostat 147 controlmode control mode enum [off|unmixed|unmixed IPM|mixed IPM] True select.thermostat_hc1_control_mode select.thermostat_hc1_controlmode
FR50 thermostat 147 charge charge boolean True switch.thermostat_dhw_charge switch.thermostat_dhw_charge
FR120 thermostat 191 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode
FR120 thermostat 191 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode
FR120 thermostat 191 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime
FR120 thermostat 191 hybridstrategy hybrid control strategy enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] True select.thermostat_hybrid_control_strategy select.thermostat_hybridstrategy
FR120 thermostat 191 switchovertemp outside switchover temperature int8 (>=-20<=20) C True number.thermostat_outside_switchover_temperature number.thermostat_switchovertemp
FR120 thermostat 191 energycostratio energy cost ratio uint8 (>=0<=20) True number.thermostat_energy_cost_ratio number.thermostat_energycostratio
FR120 thermostat 191 fossilefactor fossile energy factor uint8 (>=0<=5) True number.thermostat_fossile_energy_factor number.thermostat_fossilefactor
FR120 thermostat 191 electricfactor electric energy factor uint8 (>=0<=5) True number.thermostat_electric_energy_factor number.thermostat_electricfactor
FR120 thermostat 191 delayboiler delay boiler support uint8 (>=5<=120) minutes True number.thermostat_delay_boiler_support number.thermostat_delayboiler
FR120 thermostat 191 tempdiffboiler temp diff boiler support uint8 (>=1<=99) C True number.thermostat_temp_diff_boiler_support number.thermostat_tempdiffboiler
FR120 thermostat 191 seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp
FR120 thermostat 191 currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp
FR120 thermostat 191 haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate
FR120 thermostat 191 mode mode enum [nofrost|eco|heat|auto] True select.thermostat_hc1_mode select.thermostat_hc1_mode
FR120 thermostat 191 modetype mode type enum [nofrost|eco|heat] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype
FR120 thermostat 191 heattemp heat temperature uint8 (>=0<=127) C True number.thermostat_hc1_heat_temperature number.thermostat_hc1_heattemp
FR120 thermostat 191 ecotemp eco temperature uint8 (>=0<=127) C True number.thermostat_hc1_eco_temperature number.thermostat_hc1_ecotemp
FR120 thermostat 191 nofrosttemp nofrost temperature int8 (>=-63<=63) C True number.thermostat_hc1_nofrost_temperature number.thermostat_hc1_nofrosttemp
FR120 thermostat 191 control control device enum [off|FB10|FB100] True select.thermostat_hc1_control_device select.thermostat_hc1_control
FR120 thermostat 191 program program enum [prog a|prog b|prog c|prog d|prog e|prog f] True select.thermostat_hc1_program select.thermostat_hc1_program
FR120 thermostat 191 remotetemp room temperature from remote int16 (>=-1<=101) C True number.thermostat_hc1_room_temperature_from_remote number.thermostat_hc1_remotetemp
FR120 thermostat 191 targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp
FR120 thermostat 191 summertemp summer temperature uint8 (>=9<=25) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp
FR120 thermostat 191 roomsensor room sensor enum [extern|intern|auto] True select.thermostat_hc1_room_sensor select.thermostat_hc1_roomsensor
FR120 thermostat 191 holidaymode holiday mode enum [nofrost|eco|heat|auto] True select.thermostat_hc1_holiday_mode select.thermostat_hc1_holidaymode
FR120 thermostat 191 switchonoptimization switch-on optimization boolean True switch.thermostat_hc1_switch-on_optimization switch.thermostat_hc1_switchonoptimization
FR120 thermostat 191 heatup heatup enum [slow|medium|fast] True select.thermostat_hc1_heatup select.thermostat_hc1_heatup
FR120 thermostat 191 minflowtemp min flow temperature uint8 (>=5<=70) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp
FR120 thermostat 191 maxflowtemp max flow temperature uint8 (>=30<=90) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp
FR120 thermostat 191 designtemp design temperature uint8 (>=30<=90) C True number.thermostat_hc1_design_temperature number.thermostat_hc1_designtemp
FR120 thermostat 191 roominfluence room influence enum [off|intern|extern|auto] True select.thermostat_hc1_room_influence select.thermostat_hc1_roominfluence
FR120 thermostat 191 roominflfactor room influence factor uint8 (>=0<=100) % True number.thermostat_hc1_room_influence_factor number.thermostat_hc1_roominflfactor
FR120 thermostat 191 heatingtype heating type enum [off|heatingcurve|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype
FR120 thermostat 191 controlmode control mode enum [off|unmixed|unmixed IPM|mixed IPM] True select.thermostat_hc1_control_mode select.thermostat_hc1_controlmode
FR120 thermostat 191 charge charge boolean True switch.thermostat_dhw_charge switch.thermostat_dhw_charge
FW120 thermostat 192 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode
FW120 thermostat 192 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode
FW120 thermostat 192 datetime date/time string True sensor.thermostat_date/time sensor.thermostat_datetime
FW120 thermostat 192 hybridstrategy hybrid control strategy enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] True select.thermostat_hybrid_control_strategy select.thermostat_hybridstrategy
FW120 thermostat 192 switchovertemp outside switchover temperature int8 (>=-20<=20) C True number.thermostat_outside_switchover_temperature number.thermostat_switchovertemp
FW120 thermostat 192 energycostratio energy cost ratio uint8 (>=0<=20) True number.thermostat_energy_cost_ratio number.thermostat_energycostratio
FW120 thermostat 192 fossilefactor fossile energy factor uint8 (>=0<=5) True number.thermostat_fossile_energy_factor number.thermostat_fossilefactor
FW120 thermostat 192 electricfactor electric energy factor uint8 (>=0<=5) True number.thermostat_electric_energy_factor number.thermostat_electricfactor
FW120 thermostat 192 delayboiler delay boiler support uint8 (>=5<=120) minutes True number.thermostat_delay_boiler_support number.thermostat_delayboiler
FW120 thermostat 192 tempdiffboiler temp diff boiler support uint8 (>=1<=99) C True number.thermostat_temp_diff_boiler_support number.thermostat_tempdiffboiler
FW120 thermostat 192 seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp
FW120 thermostat 192 currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp
FW120 thermostat 192 haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate
FW120 thermostat 192 mode mode enum [nofrost|eco|heat|auto] True select.thermostat_hc1_mode select.thermostat_hc1_mode
FW120 thermostat 192 modetype mode type enum [nofrost|eco|heat] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype
FW120 thermostat 192 heattemp heat temperature uint8 (>=0<=127) C True number.thermostat_hc1_heat_temperature number.thermostat_hc1_heattemp
FW120 thermostat 192 ecotemp eco temperature uint8 (>=0<=127) C True number.thermostat_hc1_eco_temperature number.thermostat_hc1_ecotemp
FW120 thermostat 192 nofrosttemp nofrost temperature int8 (>=-63<=63) C True number.thermostat_hc1_nofrost_temperature number.thermostat_hc1_nofrosttemp
FW120 thermostat 192 control control device enum [off|FB10|FB100] True select.thermostat_hc1_control_device select.thermostat_hc1_control
FW120 thermostat 192 program program enum [prog a|prog b|prog c|prog d|prog e|prog f] True select.thermostat_hc1_program select.thermostat_hc1_program
FW120 thermostat 192 remotetemp room temperature from remote int16 (>=-1<=101) C True number.thermostat_hc1_room_temperature_from_remote number.thermostat_hc1_remotetemp
FW120 thermostat 192 targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp
FW120 thermostat 192 summertemp summer temperature uint8 (>=9<=25) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp
FW120 thermostat 192 roomsensor room sensor enum [extern|intern|auto] True select.thermostat_hc1_room_sensor select.thermostat_hc1_roomsensor
FW120 thermostat 192 holidaymode holiday mode enum [nofrost|eco|heat|auto] True select.thermostat_hc1_holiday_mode select.thermostat_hc1_holidaymode
FW120 thermostat 192 switchonoptimization switch-on optimization boolean True switch.thermostat_hc1_switch-on_optimization switch.thermostat_hc1_switchonoptimization
FW120 thermostat 192 heatup heatup enum [slow|medium|fast] True select.thermostat_hc1_heatup select.thermostat_hc1_heatup
FW120 thermostat 192 minflowtemp min flow temperature uint8 (>=5<=70) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp
FW120 thermostat 192 maxflowtemp max flow temperature uint8 (>=30<=90) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp
FW120 thermostat 192 designtemp design temperature uint8 (>=30<=90) C True number.thermostat_hc1_design_temperature number.thermostat_hc1_designtemp
FW120 thermostat 192 roominfluence room influence enum [off|intern|extern|auto] True select.thermostat_hc1_room_influence select.thermostat_hc1_roominfluence
FW120 thermostat 192 roominflfactor room influence factor uint8 (>=0<=100) % True number.thermostat_hc1_room_influence_factor number.thermostat_hc1_roominflfactor
FW120 thermostat 192 heatingtype heating type enum [off|heatingcurve|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype
FW120 thermostat 192 controlmode control mode enum [off|unmixed|unmixed IPM|mixed IPM] True select.thermostat_hc1_control_mode select.thermostat_hc1_controlmode
FW120 thermostat 192 charge charge boolean True switch.thermostat_dhw_charge switch.thermostat_dhw_charge
RT800 thermostat 3 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode
RT800 thermostat 3 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode
RT800 thermostat 3 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime
RT800 thermostat 3 seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp
RT800 thermostat 3 currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp
RT800 thermostat 3 haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate
RC100H thermostat 200 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode
RC100H thermostat 200 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode
RC100H thermostat 200 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime
RC100H thermostat 200 seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp
RC100H thermostat 200 currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp
RC100H thermostat 200 haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate
TR120RF/CR20RF thermostat 249 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode
TR120RF/CR20RF thermostat 249 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode
TR120RF/CR20RF thermostat 249 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime
TR120RF/CR20RF thermostat 249 seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp
TR120RF/CR20RF thermostat 249 currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp
TR120RF/CR20RF thermostat 249 haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate
MM10 mixer 69 flowtemphc flow temperature (TC1) uint16 (>=0<=3199) C False sensor.mixer_hc1_flow_temperature_(TC1) sensor.mixer_hc1_flowtemphc
MM10 mixer 69 valvestatus mixing valve actuator (VC1) int8 (>=-100<=100) % False sensor.mixer_hc1_mixing_valve_actuator_(VC1) sensor.mixer_hc1_valvestatus
MM10 mixer 69 flowsettemp setpoint flow temperature uint8 (>=0<=254) C True number.mixer_hc1_setpoint_flow_temperature number.mixer_hc1_flowsettemp
MM10 mixer 69 pumpstatus pump status (PC1) boolean True switch.mixer_hc1_pump_status_(PC1) switch.mixer_hc1_pumpstatus
MM10 mixer 69 activated activated boolean True switch.mixer_hc1_activated switch.mixer_hc1_activated
MM10 mixer 69 valvesettime time to set valve uint8 (>=10<=120) seconds True number.mixer_hc1_time_to_set_valve number.mixer_hc1_valvesettime
IPM mixer 100 flowtemphc flow temperature (TC1) uint16 (>=0<=3199) C False sensor.mixer_hc1_flow_temperature_(TC1) sensor.mixer_hc1_flowtemphc
IPM mixer 100 valvestatus mixing valve actuator (VC1) uint8 (>=0<=100) % False sensor.mixer_hc1_mixing_valve_actuator_(VC1) sensor.mixer_hc1_valvestatus
IPM mixer 100 flowsettemp setpoint flow temperature uint8 (>=0<=254) C True number.mixer_hc1_setpoint_flow_temperature number.mixer_hc1_flowsettemp
IPM mixer 100 pumpstatus pump status (PC1) boolean True switch.mixer_hc1_pump_status_(PC1) switch.mixer_hc1_pumpstatus
IPM mixer 100 flowtempvf flow temperature in header (T0/Vf) uint16 (>=0<=3199) C False sensor.mixer_hc1_flow_temperature_in_header_(T0/Vf) sensor.mixer_hc1_flowtempvf
IPM mixer 102 flowtemphc flow temperature (TC1) uint16 (>=0<=3199) C False sensor.mixer_hc1_flow_temperature_(TC1) sensor.mixer_hc1_flowtemphc
IPM mixer 102 valvestatus mixing valve actuator (VC1) uint8 (>=0<=100) % False sensor.mixer_hc1_mixing_valve_actuator_(VC1) sensor.mixer_hc1_valvestatus
IPM mixer 102 flowsettemp setpoint flow temperature uint8 (>=0<=254) C True number.mixer_hc1_setpoint_flow_temperature number.mixer_hc1_flowsettemp
IPM mixer 102 pumpstatus pump status (PC1) boolean True switch.mixer_hc1_pump_status_(PC1) switch.mixer_hc1_pumpstatus
IPM mixer 102 flowtempvf flow temperature in header (T0/Vf) uint16 (>=0<=3199) C False sensor.mixer_hc1_flow_temperature_in_header_(T0/Vf) sensor.mixer_hc1_flowtempvf
MM50 mixer 159 flowtemphc flow temperature (TC1) uint16 (>=0<=3199) C False sensor.mixer_hc1_flow_temperature_(TC1) sensor.mixer_hc1_flowtemphc
MM50 mixer 159 valvestatus mixing valve actuator (VC1) uint8 (>=0<=100) % False sensor.mixer_hc1_mixing_valve_actuator_(VC1) sensor.mixer_hc1_valvestatus
MM50 mixer 159 flowsettemp setpoint flow temperature uint8 (>=0<=254) C True number.mixer_hc1_setpoint_flow_temperature number.mixer_hc1_flowsettemp
MM50 mixer 159 pumpstatus pump status (PC1) boolean True switch.mixer_hc1_pump_status_(PC1) switch.mixer_hc1_pumpstatus
MM50 mixer 159 activated activated boolean True switch.mixer_hc1_activated switch.mixer_hc1_activated
MM50 mixer 159 valvesettime time to set valve uint8 (>=10<=600) seconds True number.mixer_hc1_time_to_set_valve number.mixer_hc1_valvesettime
MM50 mixer 159 flowtempoffset flow temperature offset for mixer uint8 (>=0<=20) K True number.mixer_hc1_flow_temperature_offset_for_mixer number.mixer_hc1_flowtempoffset
MM100 mixer 160 flowtemphc flow temperature (TC1) uint16 (>=0<=3199) C False sensor.mixer_dhw_flow_temperature_(TC1) sensor.mixer_dhw_flowtemphc
MM100 mixer 160 valvestatus mixing valve actuator (VC1) uint8 (>=0<=100) % False sensor.mixer_dhw_mixing_valve_actuator_(VC1) sensor.mixer_dhw_valvestatus
MM100 mixer 160 flowsettemp setpoint flow temperature uint8 (>=0<=254) C True number.mixer_dhw_setpoint_flow_temperature number.mixer_dhw_flowsettemp
MM100 mixer 160 pumpstatus pump status (PC1) boolean True switch.mixer_dhw_pump_status_(PC1) switch.mixer_dhw_pumpstatus
MM100 mixer 160 activated activated boolean True switch.mixer_dhw_activated switch.mixer_dhw_activated
MM100 mixer 160 valvesettime time to set valve uint8 (>=10<=600) seconds True number.mixer_dhw_time_to_set_valve number.mixer_dhw_valvesettime
MM100 mixer 160 flowtempoffset flow temperature offset for mixer uint8 (>=0<=20) K True number.mixer_dhw_flow_temperature_offset_for_mixer number.mixer_dhw_flowtempoffset
MM200 mixer 161 flowtemphc flow temperature (TC1) uint16 (>=0<=3199) C False sensor.mixer_hc1_flow_temperature_(TC1) sensor.mixer_hc1_flowtemphc
MM200 mixer 161 valvestatus mixing valve actuator (VC1) uint8 (>=0<=100) % False sensor.mixer_hc1_mixing_valve_actuator_(VC1) sensor.mixer_hc1_valvestatus
MM200 mixer 161 flowsettemp setpoint flow temperature uint8 (>=0<=254) C True number.mixer_hc1_setpoint_flow_temperature number.mixer_hc1_flowsettemp
MM200 mixer 161 pumpstatus pump status (PC1) boolean True switch.mixer_hc1_pump_status_(PC1) switch.mixer_hc1_pumpstatus
MM200 mixer 161 activated activated boolean True switch.mixer_hc1_activated switch.mixer_hc1_activated
MM200 mixer 161 valvesettime time to set valve uint8 (>=10<=600) seconds True number.mixer_hc1_time_to_set_valve number.mixer_hc1_valvesettime
MM200 mixer 161 flowtempoffset flow temperature offset for mixer uint8 (>=0<=20) K True number.mixer_hc1_flow_temperature_offset_for_mixer number.mixer_hc1_flowtempoffset
MZ100 mixer 193 flowtemphc flow temperature (TC1) uint16 (>=0<=3199) C False sensor.mixer_hc1_flow_temperature_(TC1) sensor.mixer_hc1_flowtemphc
MZ100 mixer 193 valvestatus mixing valve actuator (VC1) uint8 (>=0<=100) % False sensor.mixer_hc1_mixing_valve_actuator_(VC1) sensor.mixer_hc1_valvestatus
MZ100 mixer 193 flowsettemp setpoint flow temperature uint8 (>=0<=254) C True number.mixer_hc1_setpoint_flow_temperature number.mixer_hc1_flowsettemp
MZ100 mixer 193 pumpstatus pump status (PC1) boolean True switch.mixer_hc1_pump_status_(PC1) switch.mixer_hc1_pumpstatus
MZ100 mixer 193 activated activated boolean True switch.mixer_hc1_activated switch.mixer_hc1_activated
MZ100 mixer 193 valvesettime time to set valve uint8 (>=10<=600) seconds True number.mixer_hc1_time_to_set_valve number.mixer_hc1_valvesettime
MZ100 mixer 193 flowtempoffset flow temperature offset for mixer uint8 (>=0<=20) K True number.mixer_hc1_flow_temperature_offset_for_mixer number.mixer_hc1_flowtempoffset
SM10 solar 73 collectortemp collector temperature (TS1) int16 (>=-3199<=3199) C False sensor.solar_collector_temperature_(TS1) sensor.solar_collectortemp
SM10 solar 73 cylbottomtemp cylinder bottom temperature (TS2) int16 (>=-3199<=3199) C False sensor.solar_cylinder_bottom_temperature_(TS2) sensor.solar_cylbottomtemp
SM10 solar 73 solarpump pump (PS1) boolean False binary_sensor.solar_pump_(PS1) binary_sensor.solar_solarpump
SM10 solar 73 pumpworktime pump working time time (>=0<=16777213) minutes False sensor.solar_pump_working_time sensor.solar_pumpworktime
SM10 solar 73 cylmaxtemp maximum cylinder temperature uint8 (>=0<=254) C True number.solar_maximum_cylinder_temperature number.solar_cylmaxtemp
SM10 solar 73 collectorshutdown collector shutdown boolean False binary_sensor.solar_collector_shutdown binary_sensor.solar_collectorshutdown
SM10 solar 73 cylheated cyl heated boolean False binary_sensor.solar_cyl_heated binary_sensor.solar_cylheated
SM10 solar 73 solarpumpmod pump modulation (PS1) uint8 (>=0<=100) % False sensor.solar_pump_modulation_(PS1) sensor.solar_solarpumpmod
SM10 solar 73 pumpminmod minimum pump modulation uint8 (>=0<=100) % True number.solar_minimum_pump_modulation number.solar_pumpminmod
SM10 solar 73 turnondiff pump turn on difference uint8 (>=0<=254) C True number.solar_pump_turn_on_difference number.solar_turnondiff
SM10 solar 73 turnoffdiff pump turn off difference uint8 (>=0<=254) C True number.solar_pump_turn_off_difference number.solar_turnoffdiff
SM10 solar 73 solarpower actual solar power int16 (>=-31999<=31999) W False sensor.solar_actual_solar_power sensor.solar_solarpower
SM10 solar 73 energylasthour energy last hour uint24 (>=0<=1677721) Wh False sensor.solar_energy_last_hour sensor.solar_energylasthour
SM10 solar 73 maxflow maximum solar flow uint8 (>=0<=25) l/min True number.solar_maximum_solar_flow number.solar_maxflow
SM10 solar 73 mintemp minimum temperature uint8 (>=0<=254) C True number.solar_dhw_minimum_temperature number.solar_dhw_mintemp
SM10 solar 73 solarenabled solarmodule enabled boolean True switch.solar_solarmodule_enabled switch.solar_solarenabled
ISM1 solar 101 collectortemp collector temperature (TS1) int16 (>=-3199<=3199) C False sensor.solar_collector_temperature_(TS1) sensor.solar_collectortemp
ISM1 solar 101 cylbottomtemp cylinder bottom temperature (TS2) int16 (>=-3199<=3199) C False sensor.solar_cylinder_bottom_temperature_(TS2) sensor.solar_cylbottomtemp
ISM1 solar 101 solarpump pump (PS1) boolean False binary_sensor.solar_pump_(PS1) binary_sensor.solar_solarpump
ISM1 solar 101 pumpworktime pump working time time (>=0<=16777213) minutes False sensor.solar_pump_working_time sensor.solar_pumpworktime
ISM1 solar 101 cylmaxtemp maximum cylinder temperature uint8 (>=0<=254) C True number.solar_maximum_cylinder_temperature number.solar_cylmaxtemp
ISM1 solar 101 collectorshutdown collector shutdown boolean False binary_sensor.solar_collector_shutdown binary_sensor.solar_collectorshutdown
ISM1 solar 101 cylheated cyl heated boolean False binary_sensor.solar_cyl_heated binary_sensor.solar_cylheated
ISM1 solar 101 cylmiddletemp cylinder middle temperature (TS3) int16 (>=-3199<=3199) C False sensor.solar_cylinder_middle_temperature_(TS3) sensor.solar_cylmiddletemp
ISM1 solar 101 retheatassist return temperature heat assistance (TS4) int16 (>=-3199<=3199) C False sensor.solar_return_temperature_heat_assistance_(TS4) sensor.solar_retheatassist
ISM1 solar 101 heatassistvalve heat assistance valve (M1) boolean False binary_sensor.solar_heat_assistance_valve_(M1) binary_sensor.solar_heatassistvalve
ISM1 solar 101 energylasthour energy last hour uint24 (>=0<=1677721) Wh False sensor.solar_energy_last_hour sensor.solar_energylasthour
ISM2 solar 103 collectortemp collector temperature (TS1) int16 (>=-3199<=3199) C False sensor.solar_collector_temperature_(TS1) sensor.solar_collectortemp
ISM2 solar 103 cylbottomtemp cylinder bottom temperature (TS2) int16 (>=-3199<=3199) C False sensor.solar_cylinder_bottom_temperature_(TS2) sensor.solar_cylbottomtemp
ISM2 solar 103 solarpump pump (PS1) boolean False binary_sensor.solar_pump_(PS1) binary_sensor.solar_solarpump
ISM2 solar 103 pumpworktime pump working time time (>=0<=16777213) minutes False sensor.solar_pump_working_time sensor.solar_pumpworktime
ISM2 solar 103 cylmaxtemp maximum cylinder temperature uint8 (>=0<=254) C True number.solar_maximum_cylinder_temperature number.solar_cylmaxtemp
ISM2 solar 103 collectorshutdown collector shutdown boolean False binary_sensor.solar_collector_shutdown binary_sensor.solar_collectorshutdown
ISM2 solar 103 cylheated cyl heated boolean False binary_sensor.solar_cyl_heated binary_sensor.solar_cylheated
ISM2 solar 103 cylmiddletemp cylinder middle temperature (TS3) int16 (>=-3199<=3199) C False sensor.solar_cylinder_middle_temperature_(TS3) sensor.solar_cylmiddletemp
ISM2 solar 103 retheatassist return temperature heat assistance (TS4) int16 (>=-3199<=3199) C False sensor.solar_return_temperature_heat_assistance_(TS4) sensor.solar_retheatassist
ISM2 solar 103 heatassistvalve heat assistance valve (M1) boolean False binary_sensor.solar_heat_assistance_valve_(M1) binary_sensor.solar_heatassistvalve
ISM2 solar 103 energylasthour energy last hour uint24 (>=0<=1677721) Wh False sensor.solar_energy_last_hour sensor.solar_energylasthour
SM50 solar 162 collectortemp collector temperature (TS1) int16 (>=-3199<=3199) C False sensor.solar_collector_temperature_(TS1) sensor.solar_collectortemp
SM50 solar 162 cylbottomtemp cylinder bottom temperature (TS2) int16 (>=-3199<=3199) C False sensor.solar_cylinder_bottom_temperature_(TS2) sensor.solar_cylbottomtemp
SM50 solar 162 solarpump pump (PS1) boolean False binary_sensor.solar_pump_(PS1) binary_sensor.solar_solarpump
SM50 solar 162 pumpworktime pump working time time (>=0<=16777213) minutes False sensor.solar_pump_working_time sensor.solar_pumpworktime
SM50 solar 162 cylmaxtemp maximum cylinder temperature uint8 (>=0<=254) C True number.solar_maximum_cylinder_temperature number.solar_cylmaxtemp
SM50 solar 162 collectorshutdown collector shutdown boolean False binary_sensor.solar_collector_shutdown binary_sensor.solar_collectorshutdown
SM50 solar 162 cylheated cyl heated boolean False binary_sensor.solar_cyl_heated binary_sensor.solar_cylheated
SM50 solar 162 solarpumpmod pump modulation (PS1) uint8 (>=0<=100) % False sensor.solar_pump_modulation_(PS1) sensor.solar_solarpumpmod
SM50 solar 162 pumpminmod minimum pump modulation uint8 (>=0<=100) % True number.solar_minimum_pump_modulation number.solar_pumpminmod
SM50 solar 162 turnondiff pump turn on difference uint8 (>=0<=25) C True number.solar_pump_turn_on_difference number.solar_turnondiff
SM50 solar 162 turnoffdiff pump turn off difference uint8 (>=0<=25) C True number.solar_pump_turn_off_difference number.solar_turnoffdiff
SM50 solar 162 collector2temp collector 2 temperature (TS7) int16 (>=-3199<=3199) C False sensor.solar_collector_2_temperature_(TS7) sensor.solar_collector2temp
SM50 solar 162 cylmiddletemp cylinder middle temperature (TS3) int16 (>=-3199<=3199) C False sensor.solar_cylinder_middle_temperature_(TS3) sensor.solar_cylmiddletemp
SM50 solar 162 retheatassist return temperature heat assistance (TS4) int16 (>=-3199<=3199) C False sensor.solar_return_temperature_heat_assistance_(TS4) sensor.solar_retheatassist
SM50 solar 162 heatassistvalve heat assistance valve (M1) boolean False binary_sensor.solar_heat_assistance_valve_(M1) binary_sensor.solar_heatassistvalve
SM50 solar 162 heatassistpower heat assistance valve power (M1) uint8 (>=0<=100) % False sensor.solar_heat_assistance_valve_power_(M1) sensor.solar_heatassistpower
SM50 solar 162 solarpump2 pump 2 (PS4) boolean False binary_sensor.solar_pump_2_(PS4) binary_sensor.solar_solarpump2
SM50 solar 162 solarpump2mod pump 2 modulation (PS4) uint8 (>=0<=100) % False sensor.solar_pump_2_modulation_(PS4) sensor.solar_solarpump2mod
SM50 solar 162 cyl2bottomtemp second cylinder bottom temperature (TS5) int16 (>=-3199<=3199) C False sensor.solar_second_cylinder_bottom_temperature_(TS5) sensor.solar_cyl2bottomtemp
SM50 solar 162 heatexchangertemp heat exchanger temperature (TS6) int16 (>=-3199<=3199) C False sensor.solar_heat_exchanger_temperature_(TS6) sensor.solar_heatexchangertemp
SM50 solar 162 cylpumpmod cylinder pump modulation (PS5) uint8 (>=0<=100) % False sensor.solar_cylinder_pump_modulation_(PS5) sensor.solar_cylpumpmod
SM50 solar 162 valvestatus valve status boolean False binary_sensor.solar_valve_status binary_sensor.solar_valvestatus
SM50 solar 162 vs1status valve status VS1 boolean False binary_sensor.solar_valve_status_VS1 binary_sensor.solar_vs1status
SM50 solar 162 collectormaxtemp maximum collector temperature uint8 (>=0<=254) C True number.solar_maximum_collector_temperature number.solar_collectormaxtemp
SM50 solar 162 collectormintemp minimum collector temperature uint8 (>=0<=254) C True number.solar_minimum_collector_temperature number.solar_collectormintemp
SM50 solar 162 energylasthour energy last hour uint24 (>=0<=1677721) Wh False sensor.solar_energy_last_hour sensor.solar_energylasthour
SM50 solar 162 energytoday total energy today uint24 (>=0<=16777213) Wh False sensor.solar_total_energy_today sensor.solar_energytoday
SM50 solar 162 energytotal total energy uint24 (>=0<=1677721) kWh False sensor.solar_total_energy sensor.solar_energytotal
SM50 solar 162 pump2worktime pump 2 working time time (>=0<=16777213) minutes False sensor.solar_pump_2_working_time sensor.solar_pump2worktime
SM50 solar 162 m1worktime differential control working time time (>=0<=16777213) minutes False sensor.solar_differential_control_working_time sensor.solar_m1worktime
SM50 solar 162 heattransfersystem heattransfer system boolean True switch.solar_heattransfer_system switch.solar_heattransfersystem
SM50 solar 162 externalcyl external cylinder boolean True switch.solar_external_cylinder switch.solar_externalcyl
SM50 solar 162 thermaldisinfect thermal disinfection boolean True switch.solar_thermal_disinfection switch.solar_thermaldisinfect
SM50 solar 162 heatmetering heatmetering boolean True switch.solar_heatmetering switch.solar_heatmetering
SM50 solar 162 activated activated boolean True switch.solar_activated switch.solar_activated
SM50 solar 162 solarpumpmode pump mode enum [constant|pwm|analog] True select.solar_pump_mode select.solar_solarpumpmode
SM50 solar 162 pumpkick pump kick boolean True switch.solar_pump_kick switch.solar_pumpkick
SM50 solar 162 plainwatermode plain water mode boolean True switch.solar_plain_water_mode switch.solar_plainwatermode
SM50 solar 162 doublematchflow doublematchflow boolean True switch.solar_doublematchflow switch.solar_doublematchflow
SM50 solar 162 pump2minmod minimum pump 2 modulation uint8 (>=0<=100) % True number.solar_minimum_pump_2_modulation number.solar_pump2minmod
SM50 solar 162 turnondiff2 pump 2 turn on difference uint8 (>=0<=25) C True number.solar_pump_2_turn_on_difference number.solar_turnondiff2
SM50 solar 162 turnoffdiff2 pump 2 turn off difference uint8 (>=0<=25) C True number.solar_pump_2_turn_off_difference number.solar_turnoffdiff2
SM50 solar 162 pump2kick pump kick 2 boolean True switch.solar_pump_kick_2 switch.solar_pump2kick
SM50 solar 162 climatezone climate zone uint8 (>=0<=254) True number.solar_climate_zone number.solar_climatezone
SM50 solar 162 collector1area collector 1 area uint16 (>=0<=3199) m² True number.solar_collector_1_area number.solar_collector1area
SM50 solar 162 collector1type collector 1 type enum [flat|vacuum] True select.solar_collector_1_type select.solar_collector1type
SM50 solar 162 collector2area collector 2 area uint16 (>=0<=3199) m² True number.solar_collector_2_area number.solar_collector2area
SM50 solar 162 collector2type collector 2 type enum [flat|vacuum] True select.solar_collector_2_type select.solar_collector2type
SM50 solar 162 cylpriority cylinder priority enum [cyl 1|cyl 2] True select.solar_cylinder_priority select.solar_cylpriority
SM50 solar 162 heatcntflowtemp heat counter flow temperature uint16 (>=0<=3199) C False sensor.solar_heat_counter_flow_temperature sensor.solar_heatcntflowtemp
SM50 solar 162 heatcntrettemp heat counter return temperature uint16 (>=0<=3199) C False sensor.solar_heat_counter_return_temperature sensor.solar_heatcntrettemp
SM50 solar 162 heatcnt heat counter impulses uint8 (>=0<=254) False sensor.solar_heat_counter_impulses sensor.solar_heatcnt
SM50 solar 162 swapflowtemp swap flow temperature (TS14) uint16 (>=0<=3199) C False sensor.solar_swap_flow_temperature_(TS14) sensor.solar_swapflowtemp
SM50 solar 162 swaprettemp swap return temperature (TS15) uint16 (>=0<=3199) C False sensor.solar_swap_return_temperature_(TS15) sensor.solar_swaprettemp
SM100/MS100 solar 163 collectortemp collector temperature (TS1) int16 (>=-3199<=3199) C False sensor.solar_collector_temperature_(TS1) sensor.solar_collectortemp
SM100/MS100 solar 163 cylbottomtemp cylinder bottom temperature (TS2) int16 (>=-3199<=3199) C False sensor.solar_cylinder_bottom_temperature_(TS2) sensor.solar_cylbottomtemp
SM100/MS100 solar 163 solarpump pump (PS1) boolean False binary_sensor.solar_pump_(PS1) binary_sensor.solar_solarpump
SM100/MS100 solar 163 pumpworktime pump working time time (>=0<=16777213) minutes False sensor.solar_pump_working_time sensor.solar_pumpworktime
SM100/MS100 solar 163 cylmaxtemp maximum cylinder temperature uint8 (>=0<=254) C True number.solar_maximum_cylinder_temperature number.solar_cylmaxtemp
SM100/MS100 solar 163 collectorshutdown collector shutdown boolean False binary_sensor.solar_collector_shutdown binary_sensor.solar_collectorshutdown
SM100/MS100 solar 163 cylheated cyl heated boolean False binary_sensor.solar_cyl_heated binary_sensor.solar_cylheated
SM100/MS100 solar 163 solarpumpmod pump modulation (PS1) uint8 (>=0<=100) % False sensor.solar_pump_modulation_(PS1) sensor.solar_solarpumpmod
SM100/MS100 solar 163 pumpminmod minimum pump modulation uint8 (>=0<=100) % True number.solar_minimum_pump_modulation number.solar_pumpminmod
SM100/MS100 solar 163 turnondiff pump turn on difference uint8 (>=0<=25) C True number.solar_pump_turn_on_difference number.solar_turnondiff
SM100/MS100 solar 163 turnoffdiff pump turn off difference uint8 (>=0<=25) C True number.solar_pump_turn_off_difference number.solar_turnoffdiff
SM100/MS100 solar 163 collector2temp collector 2 temperature (TS7) int16 (>=-3199<=3199) C False sensor.solar_collector_2_temperature_(TS7) sensor.solar_collector2temp
SM100/MS100 solar 163 cylmiddletemp cylinder middle temperature (TS3) int16 (>=-3199<=3199) C False sensor.solar_cylinder_middle_temperature_(TS3) sensor.solar_cylmiddletemp
SM100/MS100 solar 163 retheatassist return temperature heat assistance (TS4) int16 (>=-3199<=3199) C False sensor.solar_return_temperature_heat_assistance_(TS4) sensor.solar_retheatassist
SM100/MS100 solar 163 heatassistvalve heat assistance valve (M1) boolean False binary_sensor.solar_heat_assistance_valve_(M1) binary_sensor.solar_heatassistvalve
SM100/MS100 solar 163 heatassistpower heat assistance valve power (M1) uint8 (>=0<=100) % False sensor.solar_heat_assistance_valve_power_(M1) sensor.solar_heatassistpower
SM100/MS100 solar 163 solarpump2 pump 2 (PS4) boolean False binary_sensor.solar_pump_2_(PS4) binary_sensor.solar_solarpump2
SM100/MS100 solar 163 solarpump2mod pump 2 modulation (PS4) uint8 (>=0<=100) % False sensor.solar_pump_2_modulation_(PS4) sensor.solar_solarpump2mod
SM100/MS100 solar 163 cyl2bottomtemp second cylinder bottom temperature (TS5) int16 (>=-3199<=3199) C False sensor.solar_second_cylinder_bottom_temperature_(TS5) sensor.solar_cyl2bottomtemp
SM100/MS100 solar 163 heatexchangertemp heat exchanger temperature (TS6) int16 (>=-3199<=3199) C False sensor.solar_heat_exchanger_temperature_(TS6) sensor.solar_heatexchangertemp
SM100/MS100 solar 163 cylpumpmod cylinder pump modulation (PS5) uint8 (>=0<=100) % False sensor.solar_cylinder_pump_modulation_(PS5) sensor.solar_cylpumpmod
SM100/MS100 solar 163 valvestatus valve status boolean False binary_sensor.solar_valve_status binary_sensor.solar_valvestatus
SM100/MS100 solar 163 vs1status valve status VS1 boolean False binary_sensor.solar_valve_status_VS1 binary_sensor.solar_vs1status
SM100/MS100 solar 163 collectormaxtemp maximum collector temperature uint8 (>=0<=254) C True number.solar_maximum_collector_temperature number.solar_collectormaxtemp
SM100/MS100 solar 163 collectormintemp minimum collector temperature uint8 (>=0<=254) C True number.solar_minimum_collector_temperature number.solar_collectormintemp
SM100/MS100 solar 163 energylasthour energy last hour uint24 (>=0<=1677721) Wh False sensor.solar_energy_last_hour sensor.solar_energylasthour
SM100/MS100 solar 163 energytoday total energy today uint24 (>=0<=16777213) Wh False sensor.solar_total_energy_today sensor.solar_energytoday
SM100/MS100 solar 163 energytotal total energy uint24 (>=0<=1677721) kWh False sensor.solar_total_energy sensor.solar_energytotal
SM100/MS100 solar 163 pump2worktime pump 2 working time time (>=0<=16777213) minutes False sensor.solar_pump_2_working_time sensor.solar_pump2worktime
SM100/MS100 solar 163 m1worktime differential control working time time (>=0<=16777213) minutes False sensor.solar_differential_control_working_time sensor.solar_m1worktime
SM100/MS100 solar 163 heattransfersystem heattransfer system boolean True switch.solar_heattransfer_system switch.solar_heattransfersystem
SM100/MS100 solar 163 externalcyl external cylinder boolean True switch.solar_external_cylinder switch.solar_externalcyl
SM100/MS100 solar 163 thermaldisinfect thermal disinfection boolean True switch.solar_thermal_disinfection switch.solar_thermaldisinfect
SM100/MS100 solar 163 heatmetering heatmetering boolean True switch.solar_heatmetering switch.solar_heatmetering
SM100/MS100 solar 163 activated activated boolean True switch.solar_activated switch.solar_activated
SM100/MS100 solar 163 solarpumpmode pump mode enum [constant|pwm|analog] True select.solar_pump_mode select.solar_solarpumpmode
SM100/MS100 solar 163 pumpkick pump kick boolean True switch.solar_pump_kick switch.solar_pumpkick
SM100/MS100 solar 163 plainwatermode plain water mode boolean True switch.solar_plain_water_mode switch.solar_plainwatermode
SM100/MS100 solar 163 doublematchflow doublematchflow boolean True switch.solar_doublematchflow switch.solar_doublematchflow
SM100/MS100 solar 163 pump2minmod minimum pump 2 modulation uint8 (>=0<=100) % True number.solar_minimum_pump_2_modulation number.solar_pump2minmod
SM100/MS100 solar 163 turnondiff2 pump 2 turn on difference uint8 (>=0<=25) C True number.solar_pump_2_turn_on_difference number.solar_turnondiff2
SM100/MS100 solar 163 turnoffdiff2 pump 2 turn off difference uint8 (>=0<=25) C True number.solar_pump_2_turn_off_difference number.solar_turnoffdiff2
SM100/MS100 solar 163 pump2kick pump kick 2 boolean True switch.solar_pump_kick_2 switch.solar_pump2kick
SM100/MS100 solar 163 climatezone climate zone uint8 (>=0<=254) True number.solar_climate_zone number.solar_climatezone
SM100/MS100 solar 163 collector1area collector 1 area uint16 (>=0<=3199) m² True number.solar_collector_1_area number.solar_collector1area
SM100/MS100 solar 163 collector1type collector 1 type enum [flat|vacuum] True select.solar_collector_1_type select.solar_collector1type
SM100/MS100 solar 163 collector2area collector 2 area uint16 (>=0<=3199) m² True number.solar_collector_2_area number.solar_collector2area
SM100/MS100 solar 163 collector2type collector 2 type enum [flat|vacuum] True select.solar_collector_2_type select.solar_collector2type
SM100/MS100 solar 163 cylpriority cylinder priority enum [cyl 1|cyl 2] True select.solar_cylinder_priority select.solar_cylpriority
SM100/MS100 solar 163 heatcntflowtemp heat counter flow temperature uint16 (>=0<=3199) C False sensor.solar_heat_counter_flow_temperature sensor.solar_heatcntflowtemp
SM100/MS100 solar 163 heatcntrettemp heat counter return temperature uint16 (>=0<=3199) C False sensor.solar_heat_counter_return_temperature sensor.solar_heatcntrettemp
SM100/MS100 solar 163 heatcnt heat counter impulses uint8 (>=0<=254) False sensor.solar_heat_counter_impulses sensor.solar_heatcnt
SM100/MS100 solar 163 swapflowtemp swap flow temperature (TS14) uint16 (>=0<=3199) C False sensor.solar_swap_flow_temperature_(TS14) sensor.solar_swapflowtemp
SM100/MS100 solar 163 swaprettemp swap return temperature (TS15) uint16 (>=0<=3199) C False sensor.solar_swap_return_temperature_(TS15) sensor.solar_swaprettemp
SM200/MS200 solar 164 collectortemp collector temperature (TS1) int16 (>=-3199<=3199) C False sensor.solar_collector_temperature_(TS1) sensor.solar_collectortemp
SM200/MS200 solar 164 cylbottomtemp cylinder bottom temperature (TS2) int16 (>=-3199<=3199) C False sensor.solar_cylinder_bottom_temperature_(TS2) sensor.solar_cylbottomtemp
SM200/MS200 solar 164 solarpump pump (PS1) boolean False binary_sensor.solar_pump_(PS1) binary_sensor.solar_solarpump
SM200/MS200 solar 164 pumpworktime pump working time time (>=0<=16777213) minutes False sensor.solar_pump_working_time sensor.solar_pumpworktime
SM200/MS200 solar 164 cylmaxtemp maximum cylinder temperature uint8 (>=0<=254) C True number.solar_maximum_cylinder_temperature number.solar_cylmaxtemp
SM200/MS200 solar 164 collectorshutdown collector shutdown boolean False binary_sensor.solar_collector_shutdown binary_sensor.solar_collectorshutdown
SM200/MS200 solar 164 cylheated cyl heated boolean False binary_sensor.solar_cyl_heated binary_sensor.solar_cylheated
SM200/MS200 solar 164 solarpumpmod pump modulation (PS1) uint8 (>=0<=100) % False sensor.solar_pump_modulation_(PS1) sensor.solar_solarpumpmod
SM200/MS200 solar 164 pumpminmod minimum pump modulation uint8 (>=0<=100) % True number.solar_minimum_pump_modulation number.solar_pumpminmod
SM200/MS200 solar 164 turnondiff pump turn on difference uint8 (>=0<=25) C True number.solar_pump_turn_on_difference number.solar_turnondiff
SM200/MS200 solar 164 turnoffdiff pump turn off difference uint8 (>=0<=25) C True number.solar_pump_turn_off_difference number.solar_turnoffdiff
SM200/MS200 solar 164 collector2temp collector 2 temperature (TS7) int16 (>=-3199<=3199) C False sensor.solar_collector_2_temperature_(TS7) sensor.solar_collector2temp
SM200/MS200 solar 164 cylmiddletemp cylinder middle temperature (TS3) int16 (>=-3199<=3199) C False sensor.solar_cylinder_middle_temperature_(TS3) sensor.solar_cylmiddletemp
SM200/MS200 solar 164 retheatassist return temperature heat assistance (TS4) int16 (>=-3199<=3199) C False sensor.solar_return_temperature_heat_assistance_(TS4) sensor.solar_retheatassist
SM200/MS200 solar 164 heatassistvalve heat assistance valve (M1) boolean False binary_sensor.solar_heat_assistance_valve_(M1) binary_sensor.solar_heatassistvalve
SM200/MS200 solar 164 heatassistpower heat assistance valve power (M1) uint8 (>=0<=100) % False sensor.solar_heat_assistance_valve_power_(M1) sensor.solar_heatassistpower
SM200/MS200 solar 164 solarpump2 pump 2 (PS4) boolean False binary_sensor.solar_pump_2_(PS4) binary_sensor.solar_solarpump2
SM200/MS200 solar 164 solarpump2mod pump 2 modulation (PS4) uint8 (>=0<=100) % False sensor.solar_pump_2_modulation_(PS4) sensor.solar_solarpump2mod
SM200/MS200 solar 164 cyl2bottomtemp second cylinder bottom temperature (TS5) int16 (>=-3199<=3199) C False sensor.solar_second_cylinder_bottom_temperature_(TS5) sensor.solar_cyl2bottomtemp
SM200/MS200 solar 164 heatexchangertemp heat exchanger temperature (TS6) int16 (>=-3199<=3199) C False sensor.solar_heat_exchanger_temperature_(TS6) sensor.solar_heatexchangertemp
SM200/MS200 solar 164 cylpumpmod cylinder pump modulation (PS5) uint8 (>=0<=100) % False sensor.solar_cylinder_pump_modulation_(PS5) sensor.solar_cylpumpmod
SM200/MS200 solar 164 valvestatus valve status boolean False binary_sensor.solar_valve_status binary_sensor.solar_valvestatus
SM200/MS200 solar 164 vs1status valve status VS1 boolean False binary_sensor.solar_valve_status_VS1 binary_sensor.solar_vs1status
SM200/MS200 solar 164 collectormaxtemp maximum collector temperature uint8 (>=0<=254) C True number.solar_maximum_collector_temperature number.solar_collectormaxtemp
SM200/MS200 solar 164 collectormintemp minimum collector temperature uint8 (>=0<=254) C True number.solar_minimum_collector_temperature number.solar_collectormintemp
SM200/MS200 solar 164 energylasthour energy last hour uint24 (>=0<=1677721) Wh False sensor.solar_energy_last_hour sensor.solar_energylasthour
SM200/MS200 solar 164 energytoday total energy today uint24 (>=0<=16777213) Wh False sensor.solar_total_energy_today sensor.solar_energytoday
SM200/MS200 solar 164 energytotal total energy uint24 (>=0<=1677721) kWh False sensor.solar_total_energy sensor.solar_energytotal
SM200/MS200 solar 164 pump2worktime pump 2 working time time (>=0<=16777213) minutes False sensor.solar_pump_2_working_time sensor.solar_pump2worktime
SM200/MS200 solar 164 m1worktime differential control working time time (>=0<=16777213) minutes False sensor.solar_differential_control_working_time sensor.solar_m1worktime
SM200/MS200 solar 164 heattransfersystem heattransfer system boolean True switch.solar_heattransfer_system switch.solar_heattransfersystem
SM200/MS200 solar 164 externalcyl external cylinder boolean True switch.solar_external_cylinder switch.solar_externalcyl
SM200/MS200 solar 164 thermaldisinfect thermal disinfection boolean True switch.solar_thermal_disinfection switch.solar_thermaldisinfect
SM200/MS200 solar 164 heatmetering heatmetering boolean True switch.solar_heatmetering switch.solar_heatmetering
SM200/MS200 solar 164 activated activated boolean True switch.solar_activated switch.solar_activated
SM200/MS200 solar 164 solarpumpmode pump mode enum [constant|pwm|analog] True select.solar_pump_mode select.solar_solarpumpmode
SM200/MS200 solar 164 pumpkick pump kick boolean True switch.solar_pump_kick switch.solar_pumpkick
SM200/MS200 solar 164 plainwatermode plain water mode boolean True switch.solar_plain_water_mode switch.solar_plainwatermode
SM200/MS200 solar 164 doublematchflow doublematchflow boolean True switch.solar_doublematchflow switch.solar_doublematchflow
SM200/MS200 solar 164 pump2minmod minimum pump 2 modulation uint8 (>=0<=100) % True number.solar_minimum_pump_2_modulation number.solar_pump2minmod
SM200/MS200 solar 164 turnondiff2 pump 2 turn on difference uint8 (>=0<=25) C True number.solar_pump_2_turn_on_difference number.solar_turnondiff2
SM200/MS200 solar 164 turnoffdiff2 pump 2 turn off difference uint8 (>=0<=25) C True number.solar_pump_2_turn_off_difference number.solar_turnoffdiff2
SM200/MS200 solar 164 pump2kick pump kick 2 boolean True switch.solar_pump_kick_2 switch.solar_pump2kick
SM200/MS200 solar 164 climatezone climate zone uint8 (>=0<=254) True number.solar_climate_zone number.solar_climatezone
SM200/MS200 solar 164 collector1area collector 1 area uint16 (>=0<=3199) m² True number.solar_collector_1_area number.solar_collector1area
SM200/MS200 solar 164 collector1type collector 1 type enum [flat|vacuum] True select.solar_collector_1_type select.solar_collector1type
SM200/MS200 solar 164 collector2area collector 2 area uint16 (>=0<=3199) m² True number.solar_collector_2_area number.solar_collector2area
SM200/MS200 solar 164 collector2type collector 2 type enum [flat|vacuum] True select.solar_collector_2_type select.solar_collector2type
SM200/MS200 solar 164 cylpriority cylinder priority enum [cyl 1|cyl 2] True select.solar_cylinder_priority select.solar_cylpriority
SM200/MS200 solar 164 heatcntflowtemp heat counter flow temperature uint16 (>=0<=3199) C False sensor.solar_heat_counter_flow_temperature sensor.solar_heatcntflowtemp
SM200/MS200 solar 164 heatcntrettemp heat counter return temperature uint16 (>=0<=3199) C False sensor.solar_heat_counter_return_temperature sensor.solar_heatcntrettemp
SM200/MS200 solar 164 heatcnt heat counter impulses uint8 (>=0<=254) False sensor.solar_heat_counter_impulses sensor.solar_heatcnt
SM200/MS200 solar 164 swapflowtemp swap flow temperature (TS14) uint16 (>=0<=3199) C False sensor.solar_swap_flow_temperature_(TS14) sensor.solar_swapflowtemp
SM200/MS200 solar 164 swaprettemp swap return temperature (TS15) uint16 (>=0<=3199) C False sensor.solar_swap_return_temperature_(TS15) sensor.solar_swaprettemp
HP Module heatpump 252 airhumidity relative air humidity uint8 (>=0<=100) % False sensor.heatpump_relative_air_humidity sensor.heatpump_airhumidity
HP Module heatpump 252 dewtemperature dew point temperature uint8 (>=0<=254) C False sensor.heatpump_dew_point_temperature sensor.heatpump_dewtemperature
HP Module heatpump 252 curflowtemp current flow temperature int16 (>=-3199<=3199) C False sensor.heatpump_current_flow_temperature sensor.heatpump_curflowtemp
HP Module heatpump 252 rettemp return temperature int16 (>=-3199<=3199) C False sensor.heatpump_return_temperature sensor.heatpump_rettemp
HP Module heatpump 252 sysrettemp system return temperature int16 (>=-3199<=3199) C False sensor.heatpump_system_return_temperature sensor.heatpump_sysrettemp
HP Module heatpump 252 hpta4 drain pan temp (TA4) int16 (>=-3199<=3199) C False sensor.heatpump_drain_pan_temp_(TA4) sensor.heatpump_hpta4
HP Module heatpump 252 hptr1 compressor temperature (TR1) int16 (>=-3199<=3199) C False sensor.heatpump_compressor_temperature_(TR1) sensor.heatpump_hptr1
HP Module heatpump 252 hptr3 refrigerant temperature liquid side (condenser output) (TR3) int16 (>=-3199<=3199) C False sensor.heatpump_refrigerant_temperature_liquid_side_(condenser_output)_(TR3) sensor.heatpump_hptr3
HP Module heatpump 252 hptr4 evaporator inlet temperature (TR4) int16 (>=-3199<=3199) C False sensor.heatpump_evaporator_inlet_temperature_(TR4) sensor.heatpump_hptr4
HP Module heatpump 252 hptr5 compressor inlet temperature (TR5) int16 (>=-3199<=3199) C False sensor.heatpump_compressor_inlet_temperature_(TR5) sensor.heatpump_hptr5
HP Module heatpump 252 hptr6 compressor outlet temperature (TR6) int16 (>=-3199<=3199) C False sensor.heatpump_compressor_outlet_temperature_(TR6) sensor.heatpump_hptr6
HP Module heatpump 252 hptl2 air inlet temperature (TL2) int16 (>=-3199<=3199) C False sensor.heatpump_air_inlet_temperature_(TL2) sensor.heatpump_hptl2
HP Module heatpump 252 hppl1 low pressure side temperature (PL1) int16 (>=-3199<=3199) C False sensor.heatpump_low_pressure_side_temperature_(PL1) sensor.heatpump_hppl1
HP Module heatpump 252 hpph1 high pressure side temperature (PH1) int16 (>=-3199<=3199) C False sensor.heatpump_high_pressure_side_temperature_(PH1) sensor.heatpump_hpph1
HP Module heatpump 252 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.heatpump_heating_pump_modulation sensor.heatpump_heatingpumpmod
HP Module heatpump 252 hpcompspd compressor speed uint8 (>=0<=100) % False sensor.heatpump_compressor_speed sensor.heatpump_hpcompspd
HP Module heatpump 252 hybridstrategy hybrid control strategy enum [cost optimized|co2 optimized|outside temperature alt.|outside temperature parallel|heatpump prefered|boiler only] True select.heatpump_hybrid_control_strategy select.heatpump_hybridstrategy
HP Module heatpump 252 lownoisemode low noise mode enum [off|reduced output|switch off hp|perm. reduced] True select.heatpump_low_noise_mode select.heatpump_lownoisemode
HP Module heatpump 252 lownoisestart low noise starttime uint8 (>=0<=23) True number.heatpump_low_noise_starttime number.heatpump_lownoisestart
HP Module heatpump 252 lownoisestop low noise stoptime uint8 (>=0<=23) True number.heatpump_low_noise_stoptime number.heatpump_lownoisestop
HP Module heatpump 252 hybriddhw hybrid DHW enum [eco|high comfort] True select.heatpump_hybrid_DHW select.heatpump_hybriddhw
HP Module heatpump 252 energypricegas energy price gas uint8 (>=0<=254) True number.heatpump_energy_price_gas number.heatpump_energypricegas
HP Module heatpump 252 energypriceel energy price electric uint8 (>=0<=254) True number.heatpump_energy_price_electric number.heatpump_energypriceel
HP Module heatpump 252 energyfeedpv feed in PV uint8 (>=0<=254) True number.heatpump_feed_in_PV number.heatpump_energyfeedpv
HP Module heatpump 252 switchovertemp outside switchover temperature int8 (>=-126<=126) True number.heatpump_outside_switchover_temperature number.heatpump_switchovertemp
HP Module heatpump 252 airpurgemode air purge mode boolean True switch.heatpump_air_purge_mode switch.heatpump_airpurgemode
HP Module heatpump 252 heatpumpoutput heatpump output uint8 (>=0<=100) % True number.heatpump_heatpump_output number.heatpump_heatpumpoutput
HP Module heatpump 252 coolingcircuit cooling circuit boolean True switch.heatpump_cooling_circuit switch.heatpump_coolingcircuit
HP Module heatpump 252 compstartmod compressor start modulation uint8 (>=0<=100) % True number.heatpump_compressor_start_modulation number.heatpump_compstartmod
HP Module heatpump 252 heatdrainpan heat drain pan boolean True switch.heatpump_heat_drain_pan switch.heatpump_heatdrainpan
HP Module heatpump 252 heatcable heating cable boolean True switch.heatpump_heating_cable switch.heatpump_heatcable
HP Module heatpump 252 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.heatpump_total_energy sensor.heatpump_nrgtotal
HP Module heatpump 252 nrgdhw energy uint24 (>=0<=167772) kWh False sensor.heatpump_dhw_energy sensor.heatpump_dhw_nrgdhw
HP Module heatpump 252 nrgheat energy heating uint24 (>=0<=167772) kWh False sensor.heatpump_energy_heating sensor.heatpump_nrgheat
HP Module heatpump 252 metertotal meter total uint24 (>=0<=167772) kWh False sensor.heatpump_meter_total sensor.heatpump_metertotal
HP Module heatpump 252 metercomp meter compressor uint24 (>=0<=167772) kWh False sensor.heatpump_meter_compressor sensor.heatpump_metercomp
HP Module heatpump 252 metereheat meter e-heater uint24 (>=0<=167772) kWh False sensor.heatpump_meter_e-heater sensor.heatpump_metereheat
HP Module heatpump 252 meterheat meter heating uint24 (>=0<=167772) kWh False sensor.heatpump_meter_heating sensor.heatpump_meterheat
HP Module heatpump 252 meterdhw meter uint24 (>=0<=167772) kWh False sensor.heatpump_dhw_meter sensor.heatpump_dhw_meterdhw
Hybrid Manager HM200 heatpump 248 airhumidity relative air humidity uint8 (>=0<=100) % False sensor.heatpump_relative_air_humidity sensor.heatpump_airhumidity
Hybrid Manager HM200 heatpump 248 dewtemperature dew point temperature uint8 (>=0<=254) C False sensor.heatpump_dew_point_temperature sensor.heatpump_dewtemperature
Hybrid Manager HM200 heatpump 248 curflowtemp current flow temperature int16 (>=-3199<=3199) C False sensor.heatpump_current_flow_temperature sensor.heatpump_curflowtemp
Hybrid Manager HM200 heatpump 248 rettemp return temperature int16 (>=-3199<=3199) C False sensor.heatpump_return_temperature sensor.heatpump_rettemp
Hybrid Manager HM200 heatpump 248 sysrettemp system return temperature int16 (>=-3199<=3199) C False sensor.heatpump_system_return_temperature sensor.heatpump_sysrettemp
Hybrid Manager HM200 heatpump 248 hpta4 drain pan temp (TA4) int16 (>=-3199<=3199) C False sensor.heatpump_drain_pan_temp_(TA4) sensor.heatpump_hpta4
Hybrid Manager HM200 heatpump 248 hptr1 compressor temperature (TR1) int16 (>=-3199<=3199) C False sensor.heatpump_compressor_temperature_(TR1) sensor.heatpump_hptr1
Hybrid Manager HM200 heatpump 248 hptr3 refrigerant temperature liquid side (condenser output) (TR3) int16 (>=-3199<=3199) C False sensor.heatpump_refrigerant_temperature_liquid_side_(condenser_output)_(TR3) sensor.heatpump_hptr3
Hybrid Manager HM200 heatpump 248 hptr4 evaporator inlet temperature (TR4) int16 (>=-3199<=3199) C False sensor.heatpump_evaporator_inlet_temperature_(TR4) sensor.heatpump_hptr4
Hybrid Manager HM200 heatpump 248 hptr5 compressor inlet temperature (TR5) int16 (>=-3199<=3199) C False sensor.heatpump_compressor_inlet_temperature_(TR5) sensor.heatpump_hptr5
Hybrid Manager HM200 heatpump 248 hptr6 compressor outlet temperature (TR6) int16 (>=-3199<=3199) C False sensor.heatpump_compressor_outlet_temperature_(TR6) sensor.heatpump_hptr6
Hybrid Manager HM200 heatpump 248 hptl2 air inlet temperature (TL2) int16 (>=-3199<=3199) C False sensor.heatpump_air_inlet_temperature_(TL2) sensor.heatpump_hptl2
Hybrid Manager HM200 heatpump 248 hppl1 low pressure side temperature (PL1) int16 (>=-3199<=3199) C False sensor.heatpump_low_pressure_side_temperature_(PL1) sensor.heatpump_hppl1
Hybrid Manager HM200 heatpump 248 hpph1 high pressure side temperature (PH1) int16 (>=-3199<=3199) C False sensor.heatpump_high_pressure_side_temperature_(PH1) sensor.heatpump_hpph1
Hybrid Manager HM200 heatpump 248 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.heatpump_heating_pump_modulation sensor.heatpump_heatingpumpmod
Hybrid Manager HM200 heatpump 248 hpcompspd compressor speed uint8 (>=0<=100) % False sensor.heatpump_compressor_speed sensor.heatpump_hpcompspd
Hybrid Manager HM200 heatpump 248 hybridstrategy hybrid control strategy enum [cost optimized|co2 optimized|outside temperature alt.|outside temperature parallel|heatpump prefered|boiler only] True select.heatpump_hybrid_control_strategy select.heatpump_hybridstrategy
Hybrid Manager HM200 heatpump 248 lownoisemode low noise mode enum [off|reduced output|switch off hp|perm. reduced] True select.heatpump_low_noise_mode select.heatpump_lownoisemode
Hybrid Manager HM200 heatpump 248 lownoisestart low noise starttime uint8 (>=0<=23) True number.heatpump_low_noise_starttime number.heatpump_lownoisestart
Hybrid Manager HM200 heatpump 248 lownoisestop low noise stoptime uint8 (>=0<=23) True number.heatpump_low_noise_stoptime number.heatpump_lownoisestop
Hybrid Manager HM200 heatpump 248 hybriddhw hybrid DHW enum [eco|high comfort] True select.heatpump_hybrid_DHW select.heatpump_hybriddhw
Hybrid Manager HM200 heatpump 248 energypricegas energy price gas uint8 (>=0<=254) True number.heatpump_energy_price_gas number.heatpump_energypricegas
Hybrid Manager HM200 heatpump 248 energypriceel energy price electric uint8 (>=0<=254) True number.heatpump_energy_price_electric number.heatpump_energypriceel
Hybrid Manager HM200 heatpump 248 energyfeedpv feed in PV uint8 (>=0<=254) True number.heatpump_feed_in_PV number.heatpump_energyfeedpv
Hybrid Manager HM200 heatpump 248 switchovertemp outside switchover temperature int8 (>=-126<=126) True number.heatpump_outside_switchover_temperature number.heatpump_switchovertemp
Hybrid Manager HM200 heatpump 248 airpurgemode air purge mode boolean True switch.heatpump_air_purge_mode switch.heatpump_airpurgemode
Hybrid Manager HM200 heatpump 248 heatpumpoutput heatpump output uint8 (>=0<=100) % True number.heatpump_heatpump_output number.heatpump_heatpumpoutput
Hybrid Manager HM200 heatpump 248 coolingcircuit cooling circuit boolean True switch.heatpump_cooling_circuit switch.heatpump_coolingcircuit
Hybrid Manager HM200 heatpump 248 compstartmod compressor start modulation uint8 (>=0<=100) % True number.heatpump_compressor_start_modulation number.heatpump_compstartmod
Hybrid Manager HM200 heatpump 248 heatdrainpan heat drain pan boolean True switch.heatpump_heat_drain_pan switch.heatpump_heatdrainpan
Hybrid Manager HM200 heatpump 248 heatcable heating cable boolean True switch.heatpump_heating_cable switch.heatpump_heatcable
Hybrid Manager HM200 heatpump 248 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.heatpump_total_energy sensor.heatpump_nrgtotal
Hybrid Manager HM200 heatpump 248 nrgdhw energy uint24 (>=0<=167772) kWh False sensor.heatpump_dhw_energy sensor.heatpump_dhw_nrgdhw
Hybrid Manager HM200 heatpump 248 nrgheat energy heating uint24 (>=0<=167772) kWh False sensor.heatpump_energy_heating sensor.heatpump_nrgheat
Hybrid Manager HM200 heatpump 248 metertotal meter total uint24 (>=0<=167772) kWh False sensor.heatpump_meter_total sensor.heatpump_metertotal
Hybrid Manager HM200 heatpump 248 metercomp meter compressor uint24 (>=0<=167772) kWh False sensor.heatpump_meter_compressor sensor.heatpump_metercomp
Hybrid Manager HM200 heatpump 248 metereheat meter e-heater uint24 (>=0<=167772) kWh False sensor.heatpump_meter_e-heater sensor.heatpump_metereheat
Hybrid Manager HM200 heatpump 248 meterheat meter heating uint24 (>=0<=167772) kWh False sensor.heatpump_meter_heating sensor.heatpump_meterheat
Hybrid Manager HM200 heatpump 248 meterdhw meter uint24 (>=0<=167772) kWh False sensor.heatpump_dhw_meter sensor.heatpump_dhw_meterdhw
WM10 switch 71 activated activated boolean False binary_sensor.switch_activated binary_sensor.switch_activated
WM10 switch 71 flowtemphc flow temperature (TC1) uint16 (>=0<=3199) C False sensor.switch_flow_temperature_(TC1) sensor.switch_flowtemphc
WM10 switch 71 status status int8 (>=-126<=126) False sensor.switch_status sensor.switch_status
Rego 3000 controller 240 datetime date/time string False sensor.controller_date/time sensor.controller_datetime
EM10 alert 74 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.alert_set_flow_temperature sensor.alert_setflowtemp
EM10 alert 74 setburnpow burner set power uint8 (>=0<=100) % False sensor.alert_burner_set_power sensor.alert_setburnpow
EM10/EM100 extension 243 flowtempvf flow temperature in header (T0/Vf) int16 (>=-3199<=3199) C False sensor.extension_flow_temperature_in_header_(T0/Vf) sensor.extension_flowtempvf
EM10/EM100 extension 243 input input uint8 (>=0<=25) V False sensor.extension_input sensor.extension_input
EM10/EM100 extension 243 outpow output IO1 uint8 (>=0<=100) % False sensor.extension_output_IO1 sensor.extension_outpow
EM10/EM100 extension 243 setpower request power uint8 (>=0<=100) % False sensor.extension_request_power sensor.extension_setpower
EM10/EM100 extension 243 setpoint set temp. uint8 (>=0<=254) C False sensor.extension_set_temp. sensor.extension_setpoint
EM10/EM100 extension 243 minv min volt. uint8 (>=0<=25) V True number.extension_min_volt. number.extension_minv
EM10/EM100 extension 243 maxv max volt. uint8 (>=0<=25) V True number.extension_max_volt. number.extension_maxv
EM10/EM100 extension 243 mint min temp. uint8 (>=0<=254) C True number.extension_min_temp. number.extension_mint
EM10/EM100 extension 243 maxt max temp. uint8 (>=0<=254) C True number.extension_max_temp. number.extension_maxt
EM10/EM100 extension 243 mode mode uint8 (>=0<=254) False sensor.extension_mode sensor.extension_mode
T1RF extension 220 flowtempvf flow temperature in header (T0/Vf) int16 (>=-3199<=3199) C False sensor.extension_flow_temperature_in_header_(T0/Vf) sensor.extension_flowtempvf
T1RF extension 220 input input uint8 (>=0<=25) V False sensor.extension_input sensor.extension_input
T1RF extension 220 outpow output IO1 uint8 (>=0<=100) % False sensor.extension_output_IO1 sensor.extension_outpow
T1RF extension 220 setpower request power uint8 (>=0<=100) % False sensor.extension_request_power sensor.extension_setpower
T1RF extension 220 setpoint set temp. uint8 (>=0<=254) C False sensor.extension_set_temp. sensor.extension_setpoint
T1RF extension 220 minv min volt. uint8 (>=0<=25) V True number.extension_min_volt. number.extension_minv
T1RF extension 220 maxv max volt. uint8 (>=0<=25) V True number.extension_max_volt. number.extension_maxv
T1RF extension 220 mint min temp. uint8 (>=0<=254) C True number.extension_min_temp. number.extension_mint
T1RF extension 220 maxt max temp. uint8 (>=0<=254) C True number.extension_max_temp. number.extension_maxt
T1RF extension 220 mode mode uint8 (>=0<=254) False sensor.extension_mode sensor.extension_mode
Logavent HRV176 ventilation 231 outfresh outdoor fresh air int16 (>=-3199<=3199) C False sensor.ventilation_outdoor_fresh_air sensor.ventilation_outfresh
Logavent HRV176 ventilation 231 infresh indoor fresh air int16 (>=-3199<=3199) C False sensor.ventilation_indoor_fresh_air sensor.ventilation_infresh
Logavent HRV176 ventilation 231 outexhaust outdoor exhaust air int16 (>=-3199<=3199) C False sensor.ventilation_outdoor_exhaust_air sensor.ventilation_outexhaust
Logavent HRV176 ventilation 231 inexhaust indoor exhaust air int16 (>=-3199<=3199) C False sensor.ventilation_indoor_exhaust_air sensor.ventilation_inexhaust
Logavent HRV176 ventilation 231 ventinspeed in blower speed uint8 (>=0<=100) % False sensor.ventilation_in_blower_speed sensor.ventilation_ventinspeed
Logavent HRV176 ventilation 231 ventoutspeed out blower speed uint8 (>=0<=100) % False sensor.ventilation_out_blower_speed sensor.ventilation_ventoutspeed
Logavent HRV176 ventilation 231 ventmode ventilation mode enum [auto|off|L1|L2|L3|L4|demand|sleep|intense|bypass|party|fireplace] True select.ventilation_ventilation_mode select.ventilation_ventmode
Logavent HRV176 ventilation 231 airquality air quality (voc) uint16 (>=0<=31999) False sensor.ventilation_air_quality_(voc) sensor.ventilation_airquality
Logavent HRV176 ventilation 231 airhumidity relative air humidity uint8 (>=0<=100) % False sensor.ventilation_relative_air_humidity sensor.ventilation_airhumidity
MP100 pool 204 pooltemp pool temperature int16 (>=-3199<=3199) C False sensor.pool_pool_temperature sensor.pool_pooltemp
MP100 pool 204 poolshuntstatus pool shunt status opening/closing enum [stopped|opening|closing|open|close] False sensor.pool_pool_shunt_status_opening/closing sensor.pool_poolshuntstatus
MP100 pool 204 poolshunt pool shunt open/close (0% = pool / 100% = heat) uint8 (>=0<=100) % False sensor.pool_pool_shunt_open/close_(0%=_pool/100%=_heat) sensor.pool_poolshunt