All Devices and Entities

please read

Make sure you have read and understood the Disclaimer before sending ambiguous messages to your EMS bus as you could cause serious damage to your equipment.

Most Bosch branded boilers that support the Logamatic EMS bus protocols work with this design. This includes Nefit, Buderus, Worcester, Junkers and Sieger (all copyrighted).

EMS devices are being constantly added to the database on each new release.

The following device types are supported:

  • boiler
  • thermostat
  • heatpump
  • heatsource
  • solar
  • connect
  • mixer
  • controller
  • switch
  • gateway
  • alert
  • pump

All EMS Telegrams~

Download the full CSV file

telegram_type_id name is_fetched is_cmd
0x04 UBAFactory fetched cmd
0x06 RCTime cmd
0x0A EasyMonitor fetched cmd
0x10 UBAErrorMessage1 cmd
0x11 UBAErrorMessage2 cmd
0x12 RCErrorMessage cmd
0x13 RCErrorMessage2 cmd
0x14 UBATotalUptime fetched cmd
0x15 UBAMaintenanceData cmd
0x16 UBAParameters fetched cmd
0x18 UBAMonitorFast cmd
0x19 UBAMonitorSlow cmd
0x1A UBASetPoints cmd
0x1C UBAMaintenanceStatus cmd
0x1E WM10TempMessage cmd
0x23 JunkersSetMixer fetched cmd
0x26 UBASettingsWW fetched cmd
0x28 WeatherComp fetched cmd
0x2A MC110Status cmd
0x2E Meters cmd
0x33 UBAParameterWW fetched cmd
0x34 UBAMonitorWW cmd
0x35 UBAFlags cmd
0x37 WWSettings fetched cmd
0x38 WWTimer fetched cmd
0x39 WWCircTimer fetched cmd
0x3A RC30WWSettings fetched cmd
0x3B Energy cmd
0x3D RC35Set cmd
0x3E RC35Monitor cmd
0x3F RC35Timer cmd
0x40 RC30Temp cmd
0x41 RC30Monitor cmd
0x42 RC35Timer2 cmd
0x47 RC35Set cmd
0x48 RC35Monitor cmd
0x49 RC35Timer cmd
0x4C RC35Timer2 cmd
0x51 RC35Set cmd
0x52 RC35Monitor cmd
0x53 RC35Timer cmd
0x56 RC35Timer2 cmd
0x5B RC35Set cmd
0x5C RC35Monitor cmd
0x5D RC35Timer cmd
0x60 RC35Timer2 cmd
0x96 SM10Config fetched cmd
0x97 SM10Monitor cmd
0x9C WM10MonitorMessage cmd
0x9D WM10SetMessage cmd
0xA2 RCError cmd
0xA3 RCOutdoorTemp cmd
0xA5 IBASettings fetched cmd
0xA7 RC30Set cmd
0xAA MMConfigMessage fetched cmd
0xAB MMStatusMessage cmd
0xAC MMSetMessage cmd
0xAF RC20Remote cmd
0xB0 RC10Set cmd
0xB1 RC10Monitor cmd
0xBB HybridSettings fetched cmd
0xBF ErrorMessage cmd
0xC2 UBAErrorMessage3 cmd
0xD1 UBAOutdoorTemp cmd
0xE3 UBAMonitorSlowPlus2 cmd
0xE4 UBAMonitorFastPlus cmd
0xE5 UBAMonitorSlowPlus cmd
0xE6 UBAParametersPlus fetched cmd
0xE9 UBAMonitorWWPlus cmd
0xEA UBAParameterWWPlus fetched cmd
0x0101 ISM1Set fetched cmd
0x0103 ISM1StatusMessage fetched cmd
0x0104 ISM2StatusMessage cmd
0x010C IPMStatusMessage cmd
0x011E IPMTempMessage cmd
0x0165 JunkersSet cmd
0x0166 JunkersSet cmd
0x0167 JunkersSet cmd
0x0168 JunkersSet cmd
0x016F JunkersMonitor cmd
0x0170 JunkersMonitor cmd
0x0171 JunkersMonitor cmd
0x0172 JunkersMonitor cmd
0x0179 JunkersSet cmd
0x017A JunkersSet cmd
0x017B JunkersSet cmd
0x017C JunkersSet cmd
0x01D3 JunkersDhw fetched cmd
0x023A RC300OutdoorTemp fetched cmd
0x023E PVSettings fetched cmd
0x0240 RC300Settings fetched cmd
0x0267 RC300Floordry cmd
0x0291 HPMode fetched cmd
0x0292 HPMode fetched cmd
0x0293 HPMode fetched cmd
0x0294 HPMode fetched cmd
0x029B RC300Curves cmd
0x029C RC300Curves cmd
0x029D RC300Curves cmd
0x029E RC300Curves cmd
0x029F RC300Curves cmd
0x02A0 RC300Curves cmd
0x02A1 RC300Curves cmd
0x02A2 RC300Curves cmd
0x02A5 RC300Monitor cmd
0x02A6 RC300Monitor cmd
0x02A7 CRFMonitor cmd
0x02A8 RC300Monitor cmd
0x02A9 RC300Monitor cmd
0x02AA RC300Monitor cmd
0x02AB RC300Monitor cmd
0x02AC RC300Monitor cmd
0x02AF RC300Summer cmd
0x02B0 RC300Summer cmd
0x02B1 RC300Summer cmd
0x02B2 RC300Summer cmd
0x02B3 RC300Summer cmd
0x02B4 RC300Summer cmd
0x02B5 RC300Summer cmd
0x02B6 RC300Summer cmd
0x02B9 RC300Set cmd
0x02BA RC300Set cmd
0x02BB RC300Set cmd
0x02BC RC300Set cmd
0x02BD RC300Set cmd
0x02BE RC300Set cmd
0x02BF RC300Set cmd
0x02C0 RC300Set cmd
0x02CC HPPressure fetched cmd
0x02CD MMPLUSSetMessage_HC fetched cmd
0x02CE RC300Set2 cmd
0x02D0 RC300Set2 cmd
0x02D2 RC300Set2 cmd
0x02D5 MMPLUSSetMessage_HC fetched cmd
0x02D7 MMPLUSStatusMessage_HC cmd
0x02DF MMPLUSStatusMessage_HC cmd
0x02F5 RC300WWmode fetched cmd
0x02F6 RC300WW2mode fetched cmd
0x031B RC300WWtemp fetched cmd
0x031D RC300WWmode2 cmd
0x031E RC300WWmode2 cmd
0x0358 SM100SystemConfig fetched cmd
0x035A SM100CircuitConfig fetched cmd
0x035C SM100HeatAssist fetched cmd
0x035D SM100Circuit2Config fetched cmd
0x035F SM100Config1 fetched cmd
0x0361 SM100Differential fetched cmd
0x0362 SM100Monitor cmd
0x0363 SM100Monitor2 cmd
0x0364 SM100Status cmd
0x0366 SM100Config cmd
0x036A SM100Status2 cmd
0x0380 SM100CollectorConfig fetched cmd
0x038E SM100Energy fetched cmd
0x0391 SM100Time fetched cmd
0x0467 HPSet cmd
0x0468 HPSet cmd
0x0469 HPSet cmd
0x046A HPSet cmd
0x0471 RC300Summer2 cmd
0x0472 RC300Summer2 cmd
0x0473 RC300Summer2 cmd
0x0474 RC300Summer2 cmd
0x0475 RC300Summer2 cmd
0x0476 RC300Summer2 cmd
0x0477 RC300Summer2 cmd
0x0478 RC300Summer2 cmd
0x047B HP2 cmd
0x0484 HPSilentMode fetched cmd
0x0485 HpCooling fetched cmd
0x0486 HpInConfig fetched cmd
0x0488 HPValve fetched cmd
0x048A HpPool fetched cmd
0x048B HPPumps fetched cmd
0x048D HpPower fetched cmd
0x048F HpTemperatures cmd
0x0491 HPAdditionalHeater fetched cmd
0x0492 HpHeaterConfig fetched cmd
0x0494 UBAEnergySupplied cmd
0x0495 UBAInformation cmd
0x0499 HPDhwSettings fetched cmd
0x049C HPSettings2 fetched cmd
0x049D HPSettings3 fetched cmd
0x04A2 HpInput fetched cmd
0x04A5 HPFan fetched cmd
0x04AE HPEnergy fetched cmd
0x04AF HPMeters fetched cmd
0x056B VentilationMode fetched cmd
0x0583 VentilationMonitor cmd
0x0585 Blowerspeed cmd
0x0587 Bypass cmd
0x05BA HpPoolStatus fetched cmd
0x05D9 Airquality cmd
0x0772 HIUSettings cmd
0x0779 HIUMonitor cmd
0x0935 EM100SetMessage fetched cmd
0x0936 EM100OutMessage cmd
0x0937 EM100TempMessage cmd
0x0938 EM100InputMessage cmd
0x0939 EM100MonitorMessage cmd
0x093A EM100ConfigMessage cmd
0x0998 HPSettings fetched cmd
0x0999 HPFunctionTest fetched cmd
0x099B HPFlowTemp cmd
0x099C HPComp cmd
0x09A0 HPTemperature cmd

All devices and entities~

Download the full CSV file

device name device type product id shortname fullname type [options...] | (min/max) uom writeable discovery entityid v3.4 discovery entityid
CS6800i/WLW176i boiler 8 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
CS6800i/WLW176i boiler 8 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
CS6800i/WLW176i boiler 8 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
CS6800i/WLW176i boiler 8 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
CS6800i/WLW176i boiler 8 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
CS6800i/WLW176i boiler 8 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
CS6800i/WLW176i boiler 8 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
CS6800i/WLW176i boiler 8 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
CS6800i/WLW176i boiler 8 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
CS6800i/WLW176i boiler 8 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
CS6800i/WLW176i boiler 8 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
CS6800i/WLW176i boiler 8 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
CS6800i/WLW176i boiler 8 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
CS6800i/WLW176i boiler 8 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
CS6800i/WLW176i boiler 8 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
CS6800i/WLW176i boiler 8 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
CS6800i/WLW176i boiler 8 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
CS6800i/WLW176i boiler 8 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
CS6800i/WLW176i boiler 8 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
CS6800i/WLW176i boiler 8 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
CS6800i/WLW176i boiler 8 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
CS6800i/WLW176i boiler 8 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
CS6800i/WLW176i boiler 8 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
CS6800i/WLW176i boiler 8 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
CS6800i/WLW176i boiler 8 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
CS6800i/WLW176i boiler 8 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
CS6800i/WLW176i boiler 8 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
CS6800i/WLW176i boiler 8 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
CS6800i/WLW176i boiler 8 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
CS6800i/WLW176i boiler 8 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
CS6800i/WLW176i boiler 8 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
CS6800i/WLW176i boiler 8 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
CS6800i/WLW176i boiler 8 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
CS6800i/WLW176i boiler 8 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
CS6800i/WLW176i boiler 8 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
CS6800i/WLW176i boiler 8 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
CS6800i/WLW176i boiler 8 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
CS6800i/WLW176i boiler 8 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
CS6800i/WLW176i boiler 8 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
CS6800i/WLW176i boiler 8 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal
CS6800i/WLW176i boiler 8 nrgdhw energy uint24 (>=0<=167772) kWh False sensor.boiler_dhw_energy sensor.boiler_dhw_nrgdhw
CS6800i/WLW176i boiler 8 nrgheat energy heating uint24 (>=0<=167772) kWh False sensor.boiler_energy_heating sensor.boiler_nrgheat
CS6800i/WLW176i boiler 8 metertotal meter total uint24 (>=0<=167772) kWh False sensor.boiler_meter_total sensor.boiler_metertotal
CS6800i/WLW176i boiler 8 metercomp meter compressor uint24 (>=0<=167772) kWh False sensor.boiler_meter_compressor sensor.boiler_metercomp
CS6800i/WLW176i boiler 8 metereheat meter e-heater uint24 (>=0<=167772) kWh False sensor.boiler_meter_e-heater sensor.boiler_metereheat
CS6800i/WLW176i boiler 8 meterheat meter heating uint24 (>=0<=167772) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
CS6800i/WLW176i boiler 8 meterdhw meter uint24 (>=0<=167772) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
CS6800i/WLW176i boiler 8 uptimetotal heatpump total uptime time (>=0<=279620) minutes False sensor.boiler_heatpump_total_uptime sensor.boiler_uptimetotal
CS6800i/WLW176i boiler 8 uptimecontrol total operating time heat time (>=0<=279620) minutes False sensor.boiler_total_operating_time_heat sensor.boiler_uptimecontrol
CS6800i/WLW176i boiler 8 uptimecompheating operating time compressor heating time (>=0<=279620) minutes False sensor.boiler_operating_time_compressor_heating sensor.boiler_uptimecompheating
CS6800i/WLW176i boiler 8 uptimecompcooling operating time compressor cooling time (>=0<=279620) minutes False sensor.boiler_operating_time_compressor_cooling sensor.boiler_uptimecompcooling
CS6800i/WLW176i boiler 8 uptimecompdhw operating time compressor time (>=0<=279620) minutes False sensor.boiler_dhw_operating_time_compressor sensor.boiler_dhw_uptimecompdhw
CS6800i/WLW176i boiler 8 uptimecomppool operating time compressor pool time (>=0<=279620) minutes False sensor.boiler_operating_time_compressor_pool sensor.boiler_uptimecomppool
CS6800i/WLW176i boiler 8 totalcompstarts total compressor control starts uint24 (>=0<=16777213) False sensor.boiler_total_compressor_control_starts sensor.boiler_totalcompstarts
CS6800i/WLW176i boiler 8 heatingstarts heating control starts uint24 (>=0<=16777213) False sensor.boiler_heating_control_starts sensor.boiler_heatingstarts
CS6800i/WLW176i boiler 8 coolingstarts cooling control starts uint24 (>=0<=16777213) False sensor.boiler_cooling_control_starts sensor.boiler_coolingstarts
CS6800i/WLW176i boiler 8 starts2 control starts2 uint24 (>=0<=16777213) False sensor.boiler_dhw_control_starts2 sensor.boiler_dhw_starts2
CS6800i/WLW176i boiler 8 poolstarts pool control starts uint24 (>=0<=16777213) False sensor.boiler_pool_control_starts sensor.boiler_poolstarts
CS6800i/WLW176i boiler 8 nrgconstotal total energy consumption uint24 (>=0<=16777213) kWh False sensor.boiler_total_energy_consumption sensor.boiler_nrgconstotal
CS6800i/WLW176i boiler 8 nrgconscomptotal total energy consumption compressor uint24 (>=0<=16777213) kWh False sensor.boiler_total_energy_consumption_compressor sensor.boiler_nrgconscomptotal
CS6800i/WLW176i boiler 8 nrgconscompheating energy consumption compressor heating uint24 (>=0<=16777213) kWh False sensor.boiler_energy_consumption_compressor_heating sensor.boiler_nrgconscompheating
CS6800i/WLW176i boiler 8 nrgconscompdhw energy consumption compressor uint24 (>=0<=16777213) kWh False sensor.boiler_dhw_energy_consumption_compressor sensor.boiler_dhw_nrgconscompdhw
CS6800i/WLW176i boiler 8 nrgconscompcooling energy consumption compressor cooling uint24 (>=0<=16777213) kWh False sensor.boiler_energy_consumption_compressor_cooling sensor.boiler_nrgconscompcooling
CS6800i/WLW176i boiler 8 nrgconscomppool energy consumption compressor pool uint24 (>=0<=16777213) kWh False sensor.boiler_energy_consumption_compressor_pool sensor.boiler_nrgconscomppool
CS6800i/WLW176i boiler 8 auxelecheatnrgconstotal total aux elec. heater energy consumption uint24 (>=0<=16777213) kWh False sensor.boiler_total_aux_elec._heater_energy_consumption sensor.boiler_auxelecheatnrgconstotal
CS6800i/WLW176i boiler 8 auxelecheatnrgconsheating aux elec. heater energy consumption heating uint24 (>=0<=16777213) kWh False sensor.boiler_aux_elec._heater_energy_consumption_heating sensor.boiler_auxelecheatnrgconsheating
CS6800i/WLW176i boiler 8 auxelecheatnrgconsdhw aux elec. heater energy consumption uint24 (>=0<=16777213) kWh False sensor.boiler_dhw_aux_elec._heater_energy_consumption sensor.boiler_dhw_auxelecheatnrgconsdhw
CS6800i/WLW176i boiler 8 auxelecheatnrgconspool aux elec. heater energy consumption pool uint24 (>=0<=16777213) kWh False sensor.boiler_aux_elec._heater_energy_consumption_pool sensor.boiler_auxelecheatnrgconspool
CS6800i/WLW176i boiler 8 nrgsupptotal total energy supplied uint24 (>=0<=16777213) kWh False sensor.boiler_total_energy_supplied sensor.boiler_nrgsupptotal
CS6800i/WLW176i boiler 8 nrgsuppheating total energy supplied heating uint24 (>=0<=16777213) kWh False sensor.boiler_total_energy_supplied_heating sensor.boiler_nrgsuppheating
CS6800i/WLW176i boiler 8 nrgsuppdhw total energy warm supplied uint24 (>=0<=16777213) kWh False sensor.boiler_dhw_total_energy_warm_supplied sensor.boiler_dhw_nrgsuppdhw
CS6800i/WLW176i boiler 8 nrgsuppcooling total energy supplied cooling uint24 (>=0<=16777213) kWh False sensor.boiler_total_energy_supplied_cooling sensor.boiler_nrgsuppcooling
CS6800i/WLW176i boiler 8 nrgsupppool total energy supplied pool uint24 (>=0<=16777213) kWh False sensor.boiler_total_energy_supplied_pool sensor.boiler_nrgsupppool
CS6800i/WLW176i boiler 8 hppower compressor power output uint8 (>=0<=25) kW False sensor.boiler_compressor_power_output sensor.boiler_hppower
CS6800i/WLW176i boiler 8 hpmaxpower compressor max power uint8 (>=0<=100) % True number.boiler_compressor_max_power number.boiler_hpmaxpower
CS6800i/WLW176i boiler 8 hpsetdiffpress set differental pressure uint8 (>=150<=750) mbar True number.boiler_set_differental_pressure number.boiler_hpsetdiffpress
CS6800i/WLW176i boiler 8 hpcompon hp compressor boolean False binary_sensor.boiler_hp_compressor binary_sensor.boiler_hpcompon
CS6800i/WLW176i boiler 8 hpactivity compressor activity enum [none|heating|cooling|hot water|pool|unknown|defrost] False sensor.boiler_compressor_activity sensor.boiler_hpactivity
CS6800i/WLW176i boiler 8 hpbrinepumpspd brine pump speed uint8 (>=0<=100) % False sensor.boiler_brine_pump_speed sensor.boiler_hpbrinepumpspd
CS6800i/WLW176i boiler 8 hpswitchvalve switch valve boolean False binary_sensor.boiler_switch_valve binary_sensor.boiler_hpswitchvalve
CS6800i/WLW176i boiler 8 hpcompspd compressor speed uint8 (>=0<=100) % False sensor.boiler_compressor_speed sensor.boiler_hpcompspd
CS6800i/WLW176i boiler 8 hpcircspd circulation pump speed uint8 (>=0<=100) % False sensor.boiler_circulation_pump_speed sensor.boiler_hpcircspd
CS6800i/WLW176i boiler 8 hpbrinein brine in/evaporator int16 (>=-3199<=3199) C False sensor.boiler_brine_in/evaporator sensor.boiler_hpbrinein
CS6800i/WLW176i boiler 8 hpbrineout brine out/condenser int16 (>=-3199<=3199) C False sensor.boiler_brine_out/condenser sensor.boiler_hpbrineout
CS6800i/WLW176i boiler 8 hptc0 heat carrier return (TC0) int16 (>=-3199<=3199) C False sensor.boiler_heat_carrier_return_(TC0) sensor.boiler_hptc0
CS6800i/WLW176i boiler 8 hptc1 heat carrier forward (TC1) int16 (>=-3199<=3199) C False sensor.boiler_heat_carrier_forward_(TC1) sensor.boiler_hptc1
CS6800i/WLW176i boiler 8 hptc3 condenser temperature (TC3) int16 (>=-3199<=3199) C False sensor.boiler_condenser_temperature_(TC3) sensor.boiler_hptc3
CS6800i/WLW176i boiler 8 hptr1 compressor temperature (TR1) int16 (>=-3199<=3199) C False sensor.boiler_compressor_temperature_(TR1) sensor.boiler_hptr1
CS6800i/WLW176i boiler 8 hptr3 refrigerant temperature liquid side (condenser output) (TR3) int16 (>=-3199<=3199) C False sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3) sensor.boiler_hptr3
CS6800i/WLW176i boiler 8 hptr4 evaporator inlet temperature (TR4) int16 (>=-3199<=3199) C False sensor.boiler_evaporator_inlet_temperature_(TR4) sensor.boiler_hptr4
CS6800i/WLW176i boiler 8 hptr5 compressor inlet temperature (TR5) int16 (>=-3199<=3199) C False sensor.boiler_compressor_inlet_temperature_(TR5) sensor.boiler_hptr5
CS6800i/WLW176i boiler 8 hptr6 compressor outlet temperature (TR6) int16 (>=-3199<=3199) C False sensor.boiler_compressor_outlet_temperature_(TR6) sensor.boiler_hptr6
CS6800i/WLW176i boiler 8 hptr7 refrigerant temperature gas side (condenser input) (TR7) int16 (>=-3199<=3199) C False sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7) sensor.boiler_hptr7
CS6800i/WLW176i boiler 8 hptl2 air inlet temperature (TL2) int16 (>=-3199<=3199) C False sensor.boiler_air_inlet_temperature_(TL2) sensor.boiler_hptl2
CS6800i/WLW176i boiler 8 hppl1 low pressure side temperature (PL1) int16 (>=-3199<=3199) C False sensor.boiler_low_pressure_side_temperature_(PL1) sensor.boiler_hppl1
CS6800i/WLW176i boiler 8 hpph1 high pressure side temperature (PH1) int16 (>=-3199<=3199) C False sensor.boiler_high_pressure_side_temperature_(PH1) sensor.boiler_hpph1
CS6800i/WLW176i boiler 8 hpta4 drain pan temp (TA4) int16 (>=-3199<=3199) C False sensor.boiler_drain_pan_temp_(TA4) sensor.boiler_hpta4
CS6800i/WLW176i boiler 8 hptw1 reservoir temp (TW1) int16 (>=-3199<=3199) C False sensor.boiler_reservoir_temp_(TW1) sensor.boiler_hptw1
CS6800i/WLW176i boiler 8 poolsettemp pool set temperature uint8 (>=0<=127) C True number.boiler_pool_set_temperature number.boiler_poolsettemp
CS6800i/WLW176i boiler 8 hp4way 4-way valve (VR4) enum [cooling & defrost|heating & dhw] False sensor.boiler_4-way_valve_(VR4) sensor.boiler_hp4way
CS6800i/WLW176i boiler 8 hpin1opt input 1 options string True sensor.boiler_input_1_options sensor.boiler_hpin1opt
CS6800i/WLW176i boiler 8 hpin2opt input 2 options string True sensor.boiler_input_2_options sensor.boiler_hpin2opt
CS6800i/WLW176i boiler 8 hpin3opt input 3 options string True sensor.boiler_input_3_options sensor.boiler_hpin3opt
CS6800i/WLW176i boiler 8 hpin4opt input 4 options string True sensor.boiler_input_4_options sensor.boiler_hpin4opt
CS6800i/WLW176i boiler 8 maxheatcomp heat limit compressor enum [0 kW|2 kW|3 kW|4 kW|6 kW|9 kW] True select.boiler_heat_limit_compressor select.boiler_maxheatcomp
CS6800i/WLW176i boiler 8 maxheatheat heat limit heating enum [0 kW|2 kW|3 kW|4 kW|6 kW|9 kW] True select.boiler_heat_limit_heating select.boiler_maxheatheat
CS6800i/WLW176i boiler 8 maxheatdhw heat limit enum [0 kW|2 kW|3 kW|4 kW|6 kW|9 kW] True select.boiler_dhw_heat_limit select.boiler_dhw_maxheatdhw
CS6800i/WLW176i boiler 8 mandefrost manual defrost boolean True switch.boiler_manual_defrost switch.boiler_mandefrost
CS6800i/WLW176i boiler 8 pvcooling cooling only with PV boolean True switch.boiler_cooling_only_with_PV switch.boiler_pvcooling
CS6800i/WLW176i boiler 8 auxheateronly aux heater only boolean True switch.boiler_aux_heater_only switch.boiler_auxheateronly
CS6800i/WLW176i boiler 8 auxheateroff disable aux heater boolean True switch.boiler_disable_aux_heater switch.boiler_auxheateroff
CS6800i/WLW176i boiler 8 auxheaterstatus aux heater status uint8 (>=0<=100) % False sensor.boiler_aux_heater_status sensor.boiler_auxheaterstatus
CS6800i/WLW176i boiler 8 auxheaterdelay aux heater on delay uint16 (>=10<=1000) K*min True number.boiler_aux_heater_on_delay number.boiler_auxheaterdelay
CS6800i/WLW176i boiler 8 auxmaxlimit aux heater max limit uint8 (>=0<=10) K True number.boiler_aux_heater_max_limit number.boiler_auxmaxlimit
CS6800i/WLW176i boiler 8 auxlimitstart aux heater limit start uint8 (>=0<=10) K True number.boiler_aux_heater_limit_start number.boiler_auxlimitstart
CS6800i/WLW176i boiler 8 auxheatrmode aux heater mode enum [eco|comfort] True select.boiler_aux_heater_mode select.boiler_auxheatrmode
CS6800i/WLW176i boiler 8 hphystheat on/off hyst heat uint16 (>=50<=1500) K*min True number.boiler_on/off_hyst_heat number.boiler_hphystheat
CS6800i/WLW176i boiler 8 hphystcool on/off hyst cool uint16 (>=50<=1500) K*min True number.boiler_on/off_hyst_cool number.boiler_hphystcool
CS6800i/WLW176i boiler 8 hphystpool on/off hyst pool uint16 (>=50<=1500) K*min True number.boiler_on/off_hyst_pool number.boiler_hphystpool
CS6800i/WLW176i boiler 8 silentmode silent mode enum [off|auto|on] True select.boiler_silent_mode select.boiler_silentmode
CS6800i/WLW176i boiler 8 silentfrom silent mode from uint8 (>=0<=3810) minutes True number.boiler_silent_mode_from number.boiler_silentfrom
CS6800i/WLW176i boiler 8 silentto silent mode to uint8 (>=0<=3810) minutes True number.boiler_silent_mode_to number.boiler_silentto
CS6800i/WLW176i boiler 8 mintempsilent min outside temp for silent mode int8 (>=-126<=126) C True number.boiler_min_outside_temp_for_silent_mode number.boiler_mintempsilent
CS6800i/WLW176i boiler 8 tempparmode outside temp parallel mode int8 (>=-126<=126) C True number.boiler_outside_temp_parallel_mode number.boiler_tempparmode
CS6800i/WLW176i boiler 8 auxheatmix aux heater mixing valve int8 (>=-100<=100) % False sensor.boiler_aux_heater_mixing_valve sensor.boiler_auxheatmix
CS6800i/WLW176i boiler 8 tempdiffheat temp diff TC3/TC0 heat uint8 (>=2<=10) K True number.boiler_temp_diff_TC3/TC0_heat number.boiler_tempdiffheat
CS6800i/WLW176i boiler 8 tempdiffcool temp diff TC3/TC0 cool uint8 (>=2<=10) K True number.boiler_temp_diff_TC3/TC0_cool number.boiler_tempdiffcool
CS6800i/WLW176i boiler 8 vpcooling valve/pump cooling boolean True switch.boiler_valve/pump_cooling switch.boiler_vpcooling
CS6800i/WLW176i boiler 8 heatcable heating cable boolean True switch.boiler_heating_cable switch.boiler_heatcable
CS6800i/WLW176i boiler 8 vc0valve VC0 valve boolean True switch.boiler_VC0_valve switch.boiler_vc0valve
CS6800i/WLW176i boiler 8 primepump primary heatpump boolean True switch.boiler_primary_heatpump switch.boiler_primepump
CS6800i/WLW176i boiler 8 primepumpmod primary heatpump modulation uint8 (>=0<=100) % True number.boiler_primary_heatpump_modulation number.boiler_primepumpmod
CS6800i/WLW176i boiler 8 hp3way 3-way valve boolean True switch.boiler_3-way_valve switch.boiler_hp3way
CS6800i/WLW176i boiler 8 elheatstep1 el. heater step 1 boolean True switch.boiler_el._heater_step_1 switch.boiler_elheatstep1
CS6800i/WLW176i boiler 8 elheatstep2 el. heater step 2 boolean True switch.boiler_el._heater_step_2 switch.boiler_elheatstep2
CS6800i/WLW176i boiler 8 elheatstep3 el. heater step 3 boolean True switch.boiler_el._heater_step_3 switch.boiler_elheatstep3
CS6800i/WLW176i boiler 8 hpea0 condensate reservoir heating (EA0) boolean False binary_sensor.boiler_condensate_reservoir_heating_(EA0) binary_sensor.boiler_hpea0
CS6800i/WLW176i boiler 8 hppumpmode primary heatpump mode enum [auto|continuous] True select.boiler_primary_heatpump_mode select.boiler_hppumpmode
CS6800i/WLW176i boiler 8 fan fan uint8 (>=20<=100) % True number.boiler_fan number.boiler_fan
CS6800i/WLW176i boiler 8 shutdown shutdown boolean True switch.boiler_shutdown switch.boiler_shutdown
CS6800i/WLW176i boiler 8 alternatingop alternating operation boolean True switch.boiler_dhw_alternating_operation switch.boiler_dhw_alternatingop
CS6800i/WLW176i boiler 8 altopprioheat prioritise heating during dhw uint8 (>=20<=120) minutes True number.boiler_dhw_prioritise_heating_during_dhw number.boiler_dhw_altopprioheat
CS6800i/WLW176i boiler 8 altoppriodhw prioritise dhw during heating uint8 (>=30<=120) minutes True number.boiler_dhw_prioritise_dhw_during_heating number.boiler_dhw_altoppriodhw
CS6800i/WLW176i boiler 8 comfoff comfort switch off uint8 (>=15<=65) C True number.boiler_dhw_comfort_switch_off number.boiler_dhw_comfoff
CS6800i/WLW176i boiler 8 ecooff eco switch off uint8 (>=15<=65) C True number.boiler_dhw_eco_switch_off number.boiler_dhw_ecooff
CS6800i/WLW176i boiler 8 ecoplusoff eco+ switch off uint8 (>=48<=63) C True number.boiler_dhw_eco+_switch_off number.boiler_dhw_ecoplusoff
CS6800i/WLW176i boiler 8 comfdiff comfort diff uint8 (>=6<=12) K True number.boiler_dhw_comfort_diff number.boiler_dhw_comfdiff
CS6800i/WLW176i boiler 8 ecodiff eco diff uint8 (>=6<=12) K True number.boiler_dhw_eco_diff number.boiler_dhw_ecodiff
CS6800i/WLW176i boiler 8 ecoplusdiff eco+ diff uint8 (>=6<=12) K True number.boiler_dhw_eco+_diff number.boiler_dhw_ecoplusdiff
CS6800i/WLW176i boiler 8 comfstop comfort stop temp uint8 (>=0<=254) C True number.boiler_dhw_comfort_stop_temp number.boiler_dhw_comfstop
CS6800i/WLW176i boiler 8 ecostop eco stop temp uint8 (>=0<=254) C True number.boiler_dhw_eco_stop_temp number.boiler_dhw_ecostop
CS6800i/WLW176i boiler 8 ecoplusstop eco+ stop temp uint8 (>=0<=254) C True number.boiler_dhw_eco+_stop_temp number.boiler_dhw_ecoplusstop
CS6800i/WLW176i boiler 8 hpcircpumpdhw circulation pump available during dhw boolean True switch.boiler_dhw_circulation_pump_available_during_dhw switch.boiler_dhw_hpcircpumpdhw
CS6800i/WLW176i boiler 8 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
CS6800i/WLW176i boiler 8 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
CS6800i/WLW176i boiler 8 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
CS6800i/WLW176i boiler 8 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
CS6800i/WLW176i boiler 8 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
CS6800i/WLW176i boiler 8 seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff
CS6800i/WLW176i boiler 8 seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle
CS6800i/WLW176i boiler 8 solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp
CS6800i/WLW176i boiler 8 type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type
CS6800i/WLW176i boiler 8 comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort
CS6800i/WLW176i boiler 8 comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1
CS6800i/WLW176i boiler 8 flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset
CS6800i/WLW176i boiler 8 chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization
CS6800i/WLW176i boiler 8 maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower
CS6800i/WLW176i boiler 8 maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp
CS6800i/WLW176i boiler 8 circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump
CS6800i/WLW176i boiler 8 chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype
CS6800i/WLW176i boiler 8 hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston
CS6800i/WLW176i boiler 8 hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff
CS6800i/WLW176i boiler 8 disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp
CS6800i/WLW176i boiler 8 circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode
CS6800i/WLW176i boiler 8 circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ
CS6800i/WLW176i boiler 8 curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp
CS6800i/WLW176i boiler 8 curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2
CS6800i/WLW176i boiler 8 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
CS6800i/WLW176i boiler 8 storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1
CS6800i/WLW176i boiler 8 storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2
CS6800i/WLW176i boiler 8 activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated
CS6800i/WLW176i boiler 8 onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime
CS6800i/WLW176i boiler 8 disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting
CS6800i/WLW176i boiler 8 charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging
CS6800i/WLW176i boiler 8 recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging
CS6800i/WLW176i boiler 8 tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok
CS6800i/WLW176i boiler 8 active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active
CS6800i/WLW176i boiler 8 3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve
CS6800i/WLW176i boiler 8 setpumppower set pump power uint8 (>=0<=100) % False sensor.boiler_dhw_set_pump_power sensor.boiler_dhw_setpumppower
CS6800i/WLW176i boiler 8 mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp
CS6800i/WLW176i boiler 8 cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp
CS6800i/WLW176i boiler 8 starts starts uint24 (>=0<=16777213) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts
CS6800i/WLW176i boiler 8 workm active time time (>=0<=16777213) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm
C1200W boiler 12 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
C1200W boiler 12 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
C1200W boiler 12 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
C1200W boiler 12 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
C1200W boiler 12 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
C1200W boiler 12 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
C1200W boiler 12 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
C1200W boiler 12 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
C1200W boiler 12 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
C1200W boiler 12 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
C1200W boiler 12 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
C1200W boiler 12 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
C1200W boiler 12 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
C1200W boiler 12 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp
C1200W boiler 12 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas
C1200W boiler 12 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2
C1200W boiler 12 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr
C1200W boiler 12 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork
C1200W boiler 12 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork
C1200W boiler 12 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat
C1200W boiler 12 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower
C1200W boiler 12 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower
C1200W boiler 12 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod
C1200W boiler 12 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow
C1200W boiler 12 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock
C1200W boiler 12 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston
C1200W boiler 12 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff
C1200W boiler 12 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston
C1200W boiler 12 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff
C1200W boiler 12 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon
C1200W boiler 12 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase
C1200W boiler 12 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend
C1200W boiler 12 summertemp summer temperature uint8 (>=0<=30) C True number.boiler_summer_temperature number.boiler_summertemp
C1200W boiler 12 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode
C1200W boiler 12 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp
C1200W boiler 12 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
C1200W boiler 12 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
C1200W boiler 12 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
C1200W boiler 12 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
C1200W boiler 12 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
C1200W boiler 12 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
C1200W boiler 12 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
C1200W boiler 12 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
C1200W boiler 12 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
C1200W boiler 12 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
C1200W boiler 12 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
C1200W boiler 12 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
C1200W boiler 12 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
C1200W boiler 12 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
C1200W boiler 12 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
C1200W boiler 12 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
C1200W boiler 12 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
C1200W boiler 12 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
C1200W boiler 12 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
C1200W boiler 12 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
C1200W boiler 12 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
C1200W boiler 12 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
C1200W boiler 12 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
C1200W boiler 12 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
C1200W boiler 12 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
C1200W boiler 12 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
C1200W boiler 12 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
C1200W boiler 12 meterdhw meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
C1200W boiler 12 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat
C1200W boiler 12 gasmeterdhw gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeterdhw
C1200W boiler 12 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2
C1200W boiler 12 nrgdhw2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrgdhw2
C1200W boiler 12 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
C1200W boiler 12 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
C1200W boiler 12 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
C1200W boiler 12 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
C1200W boiler 12 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
C1200W boiler 12 seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff
C1200W boiler 12 seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle
C1200W boiler 12 solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp
C1200W boiler 12 type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type
C1200W boiler 12 comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort
C1200W boiler 12 comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1
C1200W boiler 12 flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset
C1200W boiler 12 chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization
C1200W boiler 12 maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower
C1200W boiler 12 maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp
C1200W boiler 12 circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump
C1200W boiler 12 chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype
C1200W boiler 12 hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston
C1200W boiler 12 hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff
C1200W boiler 12 disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp
C1200W boiler 12 circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode
C1200W boiler 12 circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ
C1200W boiler 12 curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp
C1200W boiler 12 curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2
C1200W boiler 12 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
C1200W boiler 12 storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1
C1200W boiler 12 storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2
C1200W boiler 12 activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated
C1200W boiler 12 onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime
C1200W boiler 12 disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting
C1200W boiler 12 charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging
C1200W boiler 12 recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging
C1200W boiler 12 tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok
C1200W boiler 12 active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active
C1200W boiler 12 3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve
C1200W boiler 12 setpumppower set pump power uint8 (>=0<=100) % False sensor.boiler_dhw_set_pump_power sensor.boiler_dhw_setpumppower
C1200W boiler 12 mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp
C1200W boiler 12 cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp
C1200W boiler 12 starts starts uint24 (>=0<=16777213) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts
C1200W boiler 12 workm active time time (>=0<=16777213) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm
C1200W boiler 12 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower
C1200W boiler 12 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal
C1200W boiler 12 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat
C1200W boiler 12 nrgdhw energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrgdhw
BK13/BK15/Smartline/GB1x2 boiler 64 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
BK13/BK15/Smartline/GB1x2 boiler 64 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
BK13/BK15/Smartline/GB1x2 boiler 64 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
BK13/BK15/Smartline/GB1x2 boiler 64 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
BK13/BK15/Smartline/GB1x2 boiler 64 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
BK13/BK15/Smartline/GB1x2 boiler 64 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
BK13/BK15/Smartline/GB1x2 boiler 64 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
BK13/BK15/Smartline/GB1x2 boiler 64 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
BK13/BK15/Smartline/GB1x2 boiler 64 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
BK13/BK15/Smartline/GB1x2 boiler 64 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
BK13/BK15/Smartline/GB1x2 boiler 64 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
BK13/BK15/Smartline/GB1x2 boiler 64 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
BK13/BK15/Smartline/GB1x2 boiler 64 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
BK13/BK15/Smartline/GB1x2 boiler 64 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp
BK13/BK15/Smartline/GB1x2 boiler 64 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas
BK13/BK15/Smartline/GB1x2 boiler 64 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2
BK13/BK15/Smartline/GB1x2 boiler 64 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr
BK13/BK15/Smartline/GB1x2 boiler 64 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork
BK13/BK15/Smartline/GB1x2 boiler 64 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork
BK13/BK15/Smartline/GB1x2 boiler 64 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat
BK13/BK15/Smartline/GB1x2 boiler 64 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower
BK13/BK15/Smartline/GB1x2 boiler 64 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower
BK13/BK15/Smartline/GB1x2 boiler 64 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod
BK13/BK15/Smartline/GB1x2 boiler 64 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow
BK13/BK15/Smartline/GB1x2 boiler 64 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock
BK13/BK15/Smartline/GB1x2 boiler 64 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston
BK13/BK15/Smartline/GB1x2 boiler 64 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff
BK13/BK15/Smartline/GB1x2 boiler 64 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston
BK13/BK15/Smartline/GB1x2 boiler 64 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff
BK13/BK15/Smartline/GB1x2 boiler 64 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon
BK13/BK15/Smartline/GB1x2 boiler 64 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase
BK13/BK15/Smartline/GB1x2 boiler 64 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend
BK13/BK15/Smartline/GB1x2 boiler 64 summertemp summer temperature uint8 (>=0<=30) C True number.boiler_summer_temperature number.boiler_summertemp
BK13/BK15/Smartline/GB1x2 boiler 64 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode
BK13/BK15/Smartline/GB1x2 boiler 64 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp
BK13/BK15/Smartline/GB1x2 boiler 64 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
BK13/BK15/Smartline/GB1x2 boiler 64 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
BK13/BK15/Smartline/GB1x2 boiler 64 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
BK13/BK15/Smartline/GB1x2 boiler 64 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
BK13/BK15/Smartline/GB1x2 boiler 64 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
BK13/BK15/Smartline/GB1x2 boiler 64 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
BK13/BK15/Smartline/GB1x2 boiler 64 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
BK13/BK15/Smartline/GB1x2 boiler 64 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
BK13/BK15/Smartline/GB1x2 boiler 64 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
BK13/BK15/Smartline/GB1x2 boiler 64 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
BK13/BK15/Smartline/GB1x2 boiler 64 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
BK13/BK15/Smartline/GB1x2 boiler 64 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
BK13/BK15/Smartline/GB1x2 boiler 64 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
BK13/BK15/Smartline/GB1x2 boiler 64 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
BK13/BK15/Smartline/GB1x2 boiler 64 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
BK13/BK15/Smartline/GB1x2 boiler 64 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
BK13/BK15/Smartline/GB1x2 boiler 64 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
BK13/BK15/Smartline/GB1x2 boiler 64 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
BK13/BK15/Smartline/GB1x2 boiler 64 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
BK13/BK15/Smartline/GB1x2 boiler 64 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
BK13/BK15/Smartline/GB1x2 boiler 64 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
BK13/BK15/Smartline/GB1x2 boiler 64 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
BK13/BK15/Smartline/GB1x2 boiler 64 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
BK13/BK15/Smartline/GB1x2 boiler 64 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
BK13/BK15/Smartline/GB1x2 boiler 64 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
BK13/BK15/Smartline/GB1x2 boiler 64 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
BK13/BK15/Smartline/GB1x2 boiler 64 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
BK13/BK15/Smartline/GB1x2 boiler 64 meterdhw meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
BK13/BK15/Smartline/GB1x2 boiler 64 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat
BK13/BK15/Smartline/GB1x2 boiler 64 gasmeterdhw gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeterdhw
BK13/BK15/Smartline/GB1x2 boiler 64 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2
BK13/BK15/Smartline/GB1x2 boiler 64 nrgdhw2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrgdhw2
BK13/BK15/Smartline/GB1x2 boiler 64 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
BK13/BK15/Smartline/GB1x2 boiler 64 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
BK13/BK15/Smartline/GB1x2 boiler 64 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
BK13/BK15/Smartline/GB1x2 boiler 64 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
BK13/BK15/Smartline/GB1x2 boiler 64 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
BK13/BK15/Smartline/GB1x2 boiler 64 seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff
BK13/BK15/Smartline/GB1x2 boiler 64 seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle
BK13/BK15/Smartline/GB1x2 boiler 64 solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp
BK13/BK15/Smartline/GB1x2 boiler 64 type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type
BK13/BK15/Smartline/GB1x2 boiler 64 comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort
BK13/BK15/Smartline/GB1x2 boiler 64 comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1
BK13/BK15/Smartline/GB1x2 boiler 64 flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset
BK13/BK15/Smartline/GB1x2 boiler 64 chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization
BK13/BK15/Smartline/GB1x2 boiler 64 maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower
BK13/BK15/Smartline/GB1x2 boiler 64 maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp
BK13/BK15/Smartline/GB1x2 boiler 64 circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump
BK13/BK15/Smartline/GB1x2 boiler 64 chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype
BK13/BK15/Smartline/GB1x2 boiler 64 hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston
BK13/BK15/Smartline/GB1x2 boiler 64 hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff
BK13/BK15/Smartline/GB1x2 boiler 64 disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp
BK13/BK15/Smartline/GB1x2 boiler 64 circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode
BK13/BK15/Smartline/GB1x2 boiler 64 circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ
BK13/BK15/Smartline/GB1x2 boiler 64 curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp
BK13/BK15/Smartline/GB1x2 boiler 64 curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2
BK13/BK15/Smartline/GB1x2 boiler 64 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
BK13/BK15/Smartline/GB1x2 boiler 64 storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1
BK13/BK15/Smartline/GB1x2 boiler 64 storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2
BK13/BK15/Smartline/GB1x2 boiler 64 activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated
BK13/BK15/Smartline/GB1x2 boiler 64 onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime
BK13/BK15/Smartline/GB1x2 boiler 64 disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting
BK13/BK15/Smartline/GB1x2 boiler 64 charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging
BK13/BK15/Smartline/GB1x2 boiler 64 recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging
BK13/BK15/Smartline/GB1x2 boiler 64 tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok
BK13/BK15/Smartline/GB1x2 boiler 64 active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active
BK13/BK15/Smartline/GB1x2 boiler 64 3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve
BK13/BK15/Smartline/GB1x2 boiler 64 setpumppower set pump power uint8 (>=0<=100) % False sensor.boiler_dhw_set_pump_power sensor.boiler_dhw_setpumppower
BK13/BK15/Smartline/GB1x2 boiler 64 mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp
BK13/BK15/Smartline/GB1x2 boiler 64 cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp
BK13/BK15/Smartline/GB1x2 boiler 64 starts starts uint24 (>=0<=16777213) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts
BK13/BK15/Smartline/GB1x2 boiler 64 workm active time time (>=0<=16777213) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm
BK13/BK15/Smartline/GB1x2 boiler 64 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower
BK13/BK15/Smartline/GB1x2 boiler 64 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal
BK13/BK15/Smartline/GB1x2 boiler 64 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat
BK13/BK15/Smartline/GB1x2 boiler 64 nrgdhw energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrgdhw
GB125/GB135/MC10 boiler 72 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
GB125/GB135/MC10 boiler 72 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
GB125/GB135/MC10 boiler 72 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
GB125/GB135/MC10 boiler 72 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
GB125/GB135/MC10 boiler 72 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
GB125/GB135/MC10 boiler 72 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
GB125/GB135/MC10 boiler 72 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
GB125/GB135/MC10 boiler 72 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
GB125/GB135/MC10 boiler 72 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
GB125/GB135/MC10 boiler 72 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
GB125/GB135/MC10 boiler 72 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
GB125/GB135/MC10 boiler 72 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
GB125/GB135/MC10 boiler 72 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
GB125/GB135/MC10 boiler 72 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp
GB125/GB135/MC10 boiler 72 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas
GB125/GB135/MC10 boiler 72 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2
GB125/GB135/MC10 boiler 72 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr
GB125/GB135/MC10 boiler 72 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork
GB125/GB135/MC10 boiler 72 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork
GB125/GB135/MC10 boiler 72 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat
GB125/GB135/MC10 boiler 72 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower
GB125/GB135/MC10 boiler 72 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower
GB125/GB135/MC10 boiler 72 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod
GB125/GB135/MC10 boiler 72 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow
GB125/GB135/MC10 boiler 72 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock
GB125/GB135/MC10 boiler 72 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston
GB125/GB135/MC10 boiler 72 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff
GB125/GB135/MC10 boiler 72 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston
GB125/GB135/MC10 boiler 72 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff
GB125/GB135/MC10 boiler 72 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon
GB125/GB135/MC10 boiler 72 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase
GB125/GB135/MC10 boiler 72 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend
GB125/GB135/MC10 boiler 72 summertemp summer temperature uint8 (>=0<=30) C True number.boiler_summer_temperature number.boiler_summertemp
GB125/GB135/MC10 boiler 72 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode
GB125/GB135/MC10 boiler 72 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp
GB125/GB135/MC10 boiler 72 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
GB125/GB135/MC10 boiler 72 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
GB125/GB135/MC10 boiler 72 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
GB125/GB135/MC10 boiler 72 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
GB125/GB135/MC10 boiler 72 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
GB125/GB135/MC10 boiler 72 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
GB125/GB135/MC10 boiler 72 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
GB125/GB135/MC10 boiler 72 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
GB125/GB135/MC10 boiler 72 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
GB125/GB135/MC10 boiler 72 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
GB125/GB135/MC10 boiler 72 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
GB125/GB135/MC10 boiler 72 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
GB125/GB135/MC10 boiler 72 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
GB125/GB135/MC10 boiler 72 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
GB125/GB135/MC10 boiler 72 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
GB125/GB135/MC10 boiler 72 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
GB125/GB135/MC10 boiler 72 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
GB125/GB135/MC10 boiler 72 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
GB125/GB135/MC10 boiler 72 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
GB125/GB135/MC10 boiler 72 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
GB125/GB135/MC10 boiler 72 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
GB125/GB135/MC10 boiler 72 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
GB125/GB135/MC10 boiler 72 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
GB125/GB135/MC10 boiler 72 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
GB125/GB135/MC10 boiler 72 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
GB125/GB135/MC10 boiler 72 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
GB125/GB135/MC10 boiler 72 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
GB125/GB135/MC10 boiler 72 meterdhw meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
GB125/GB135/MC10 boiler 72 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat
GB125/GB135/MC10 boiler 72 gasmeterdhw gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeterdhw
GB125/GB135/MC10 boiler 72 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2
GB125/GB135/MC10 boiler 72 nrgdhw2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrgdhw2
GB125/GB135/MC10 boiler 72 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
GB125/GB135/MC10 boiler 72 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
GB125/GB135/MC10 boiler 72 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
GB125/GB135/MC10 boiler 72 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
GB125/GB135/MC10 boiler 72 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
GB125/GB135/MC10 boiler 72 seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff
GB125/GB135/MC10 boiler 72 seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle
GB125/GB135/MC10 boiler 72 solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp
GB125/GB135/MC10 boiler 72 type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type
GB125/GB135/MC10 boiler 72 comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort
GB125/GB135/MC10 boiler 72 comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1
GB125/GB135/MC10 boiler 72 flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset
GB125/GB135/MC10 boiler 72 chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization
GB125/GB135/MC10 boiler 72 maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower
GB125/GB135/MC10 boiler 72 maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp
GB125/GB135/MC10 boiler 72 circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump
GB125/GB135/MC10 boiler 72 chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype
GB125/GB135/MC10 boiler 72 hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston
GB125/GB135/MC10 boiler 72 hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff
GB125/GB135/MC10 boiler 72 disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp
GB125/GB135/MC10 boiler 72 circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode
GB125/GB135/MC10 boiler 72 circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ
GB125/GB135/MC10 boiler 72 curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp
GB125/GB135/MC10 boiler 72 curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2
GB125/GB135/MC10 boiler 72 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
GB125/GB135/MC10 boiler 72 storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1
GB125/GB135/MC10 boiler 72 storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2
GB125/GB135/MC10 boiler 72 activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated
GB125/GB135/MC10 boiler 72 onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime
GB125/GB135/MC10 boiler 72 disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting
GB125/GB135/MC10 boiler 72 charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging
GB125/GB135/MC10 boiler 72 recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging
GB125/GB135/MC10 boiler 72 tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok
GB125/GB135/MC10 boiler 72 active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active
GB125/GB135/MC10 boiler 72 3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve
GB125/GB135/MC10 boiler 72 setpumppower set pump power uint8 (>=0<=100) % False sensor.boiler_dhw_set_pump_power sensor.boiler_dhw_setpumppower
GB125/GB135/MC10 boiler 72 mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp
GB125/GB135/MC10 boiler 72 cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp
GB125/GB135/MC10 boiler 72 starts starts uint24 (>=0<=16777213) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts
GB125/GB135/MC10 boiler 72 workm active time time (>=0<=16777213) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm
GB125/GB135/MC10 boiler 72 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower
GB125/GB135/MC10 boiler 72 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal
GB125/GB135/MC10 boiler 72 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat
GB125/GB135/MC10 boiler 72 nrgdhw energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrgdhw
Cascade CM10 boiler 81 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
Cascade CM10 boiler 81 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
Cascade CM10 boiler 81 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
Cascade CM10 boiler 81 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
Cascade CM10 boiler 81 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
Cascade CM10 boiler 81 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
Cascade CM10 boiler 81 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
Cascade CM10 boiler 81 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
Cascade CM10 boiler 81 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
Cascade CM10 boiler 81 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
Cascade CM10 boiler 81 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
Cascade CM10 boiler 81 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
Cascade CM10 boiler 81 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
Cascade CM10 boiler 81 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp
Cascade CM10 boiler 81 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas
Cascade CM10 boiler 81 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2
Cascade CM10 boiler 81 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr
Cascade CM10 boiler 81 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork
Cascade CM10 boiler 81 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork
Cascade CM10 boiler 81 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat
Cascade CM10 boiler 81 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower
Cascade CM10 boiler 81 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower
Cascade CM10 boiler 81 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod
Cascade CM10 boiler 81 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow
Cascade CM10 boiler 81 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock
Cascade CM10 boiler 81 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston
Cascade CM10 boiler 81 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff
Cascade CM10 boiler 81 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston
Cascade CM10 boiler 81 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff
Cascade CM10 boiler 81 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon
Cascade CM10 boiler 81 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase
Cascade CM10 boiler 81 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend
Cascade CM10 boiler 81 summertemp summer temperature uint8 (>=0<=30) C True number.boiler_summer_temperature number.boiler_summertemp
Cascade CM10 boiler 81 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode
Cascade CM10 boiler 81 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp
Cascade CM10 boiler 81 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
Cascade CM10 boiler 81 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
Cascade CM10 boiler 81 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
Cascade CM10 boiler 81 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
Cascade CM10 boiler 81 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
Cascade CM10 boiler 81 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
Cascade CM10 boiler 81 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
Cascade CM10 boiler 81 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
Cascade CM10 boiler 81 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
Cascade CM10 boiler 81 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
Cascade CM10 boiler 81 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
Cascade CM10 boiler 81 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
Cascade CM10 boiler 81 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
Cascade CM10 boiler 81 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
Cascade CM10 boiler 81 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
Cascade CM10 boiler 81 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
Cascade CM10 boiler 81 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
Cascade CM10 boiler 81 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
Cascade CM10 boiler 81 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
Cascade CM10 boiler 81 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
Cascade CM10 boiler 81 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
Cascade CM10 boiler 81 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
Cascade CM10 boiler 81 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
Cascade CM10 boiler 81 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
Cascade CM10 boiler 81 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
Cascade CM10 boiler 81 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
Cascade CM10 boiler 81 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
Cascade CM10 boiler 81 meterdhw meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
Cascade CM10 boiler 81 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat
Cascade CM10 boiler 81 gasmeterdhw gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeterdhw
Cascade CM10 boiler 81 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2
Cascade CM10 boiler 81 nrgdhw2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrgdhw2
Cascade CM10 boiler 81 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
Cascade CM10 boiler 81 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
Cascade CM10 boiler 81 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
Cascade CM10 boiler 81 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
Cascade CM10 boiler 81 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
Cascade CM10 boiler 81 seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff
Cascade CM10 boiler 81 seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle
Cascade CM10 boiler 81 solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp
Cascade CM10 boiler 81 type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type
Cascade CM10 boiler 81 comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort
Cascade CM10 boiler 81 comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1
Cascade CM10 boiler 81 flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset
Cascade CM10 boiler 81 chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization
Cascade CM10 boiler 81 maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower
Cascade CM10 boiler 81 maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp
Cascade CM10 boiler 81 circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump
Cascade CM10 boiler 81 chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype
Cascade CM10 boiler 81 hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston
Cascade CM10 boiler 81 hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff
Cascade CM10 boiler 81 disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp
Cascade CM10 boiler 81 circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode
Cascade CM10 boiler 81 circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ
Cascade CM10 boiler 81 curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp
Cascade CM10 boiler 81 curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2
Cascade CM10 boiler 81 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
Cascade CM10 boiler 81 storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1
Cascade CM10 boiler 81 storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2
Cascade CM10 boiler 81 activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated
Cascade CM10 boiler 81 onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime
Cascade CM10 boiler 81 disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting
Cascade CM10 boiler 81 charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging
Cascade CM10 boiler 81 recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging
Cascade CM10 boiler 81 tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok
Cascade CM10 boiler 81 active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active
Cascade CM10 boiler 81 3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve
Cascade CM10 boiler 81 setpumppower set pump power uint8 (>=0<=100) % False sensor.boiler_dhw_set_pump_power sensor.boiler_dhw_setpumppower
Cascade CM10 boiler 81 mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp
Cascade CM10 boiler 81 cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp
Cascade CM10 boiler 81 starts starts uint24 (>=0<=16777213) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts
Cascade CM10 boiler 81 workm active time time (>=0<=16777213) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm
Cascade CM10 boiler 81 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower
Cascade CM10 boiler 81 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal
Cascade CM10 boiler 81 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat
Cascade CM10 boiler 81 nrgdhw energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrgdhw
Logamax Plus GB022 boiler 84 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
Logamax Plus GB022 boiler 84 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
Logamax Plus GB022 boiler 84 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
Logamax Plus GB022 boiler 84 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
Logamax Plus GB022 boiler 84 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
Logamax Plus GB022 boiler 84 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
Logamax Plus GB022 boiler 84 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
Logamax Plus GB022 boiler 84 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
Logamax Plus GB022 boiler 84 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
Logamax Plus GB022 boiler 84 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
Logamax Plus GB022 boiler 84 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
Logamax Plus GB022 boiler 84 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
Logamax Plus GB022 boiler 84 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
Logamax Plus GB022 boiler 84 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp
Logamax Plus GB022 boiler 84 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas
Logamax Plus GB022 boiler 84 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2
Logamax Plus GB022 boiler 84 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr
Logamax Plus GB022 boiler 84 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork
Logamax Plus GB022 boiler 84 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork
Logamax Plus GB022 boiler 84 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat
Logamax Plus GB022 boiler 84 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower
Logamax Plus GB022 boiler 84 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower
Logamax Plus GB022 boiler 84 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod
Logamax Plus GB022 boiler 84 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow
Logamax Plus GB022 boiler 84 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock
Logamax Plus GB022 boiler 84 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston
Logamax Plus GB022 boiler 84 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff
Logamax Plus GB022 boiler 84 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston
Logamax Plus GB022 boiler 84 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff
Logamax Plus GB022 boiler 84 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon
Logamax Plus GB022 boiler 84 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase
Logamax Plus GB022 boiler 84 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend
Logamax Plus GB022 boiler 84 summertemp summer temperature uint8 (>=0<=30) C True number.boiler_summer_temperature number.boiler_summertemp
Logamax Plus GB022 boiler 84 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode
Logamax Plus GB022 boiler 84 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp
Logamax Plus GB022 boiler 84 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
Logamax Plus GB022 boiler 84 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
Logamax Plus GB022 boiler 84 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
Logamax Plus GB022 boiler 84 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
Logamax Plus GB022 boiler 84 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
Logamax Plus GB022 boiler 84 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
Logamax Plus GB022 boiler 84 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
Logamax Plus GB022 boiler 84 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
Logamax Plus GB022 boiler 84 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
Logamax Plus GB022 boiler 84 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
Logamax Plus GB022 boiler 84 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
Logamax Plus GB022 boiler 84 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
Logamax Plus GB022 boiler 84 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
Logamax Plus GB022 boiler 84 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
Logamax Plus GB022 boiler 84 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
Logamax Plus GB022 boiler 84 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
Logamax Plus GB022 boiler 84 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
Logamax Plus GB022 boiler 84 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
Logamax Plus GB022 boiler 84 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
Logamax Plus GB022 boiler 84 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
Logamax Plus GB022 boiler 84 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
Logamax Plus GB022 boiler 84 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
Logamax Plus GB022 boiler 84 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
Logamax Plus GB022 boiler 84 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
Logamax Plus GB022 boiler 84 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
Logamax Plus GB022 boiler 84 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
Logamax Plus GB022 boiler 84 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
Logamax Plus GB022 boiler 84 meterdhw meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
Logamax Plus GB022 boiler 84 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat
Logamax Plus GB022 boiler 84 gasmeterdhw gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeterdhw
Logamax Plus GB022 boiler 84 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2
Logamax Plus GB022 boiler 84 nrgdhw2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrgdhw2
Logamax Plus GB022 boiler 84 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
Logamax Plus GB022 boiler 84 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
Logamax Plus GB022 boiler 84 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
Logamax Plus GB022 boiler 84 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
Logamax Plus GB022 boiler 84 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
Logamax Plus GB022 boiler 84 seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff
Logamax Plus GB022 boiler 84 seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle
Logamax Plus GB022 boiler 84 solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp
Logamax Plus GB022 boiler 84 type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type
Logamax Plus GB022 boiler 84 comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort
Logamax Plus GB022 boiler 84 comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1
Logamax Plus GB022 boiler 84 flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset
Logamax Plus GB022 boiler 84 chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization
Logamax Plus GB022 boiler 84 maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower
Logamax Plus GB022 boiler 84 maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp
Logamax Plus GB022 boiler 84 circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump
Logamax Plus GB022 boiler 84 chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype
Logamax Plus GB022 boiler 84 hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston
Logamax Plus GB022 boiler 84 hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff
Logamax Plus GB022 boiler 84 disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp
Logamax Plus GB022 boiler 84 circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode
Logamax Plus GB022 boiler 84 circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ
Logamax Plus GB022 boiler 84 curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp
Logamax Plus GB022 boiler 84 curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2
Logamax Plus GB022 boiler 84 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
Logamax Plus GB022 boiler 84 storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1
Logamax Plus GB022 boiler 84 storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2
Logamax Plus GB022 boiler 84 activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated
Logamax Plus GB022 boiler 84 onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime
Logamax Plus GB022 boiler 84 disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting
Logamax Plus GB022 boiler 84 charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging
Logamax Plus GB022 boiler 84 recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging
Logamax Plus GB022 boiler 84 tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok
Logamax Plus GB022 boiler 84 active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active
Logamax Plus GB022 boiler 84 3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve
Logamax Plus GB022 boiler 84 setpumppower set pump power uint8 (>=0<=100) % False sensor.boiler_dhw_set_pump_power sensor.boiler_dhw_setpumppower
Logamax Plus GB022 boiler 84 mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp
Logamax Plus GB022 boiler 84 cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp
Logamax Plus GB022 boiler 84 starts starts uint24 (>=0<=16777213) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts
Logamax Plus GB022 boiler 84 workm active time time (>=0<=16777213) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm
Logamax Plus GB022 boiler 84 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower
Logamax Plus GB022 boiler 84 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal
Logamax Plus GB022 boiler 84 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat
Logamax Plus GB022 boiler 84 nrgdhw energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrgdhw
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 summertemp summer temperature uint8 (>=0<=30) C True number.boiler_summer_temperature number.boiler_summertemp
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 meterdhw meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 gasmeterdhw gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeterdhw
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 nrgdhw2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrgdhw2
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 setpumppower set pump power uint8 (>=0<=100) % False sensor.boiler_dhw_set_pump_power sensor.boiler_dhw_setpumppower
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 starts starts uint24 (>=0<=16777213) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 workm active time time (>=0<=16777213) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 boiler 95 nrgdhw energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrgdhw
Topline/GB162 boiler 115 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
Topline/GB162 boiler 115 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
Topline/GB162 boiler 115 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
Topline/GB162 boiler 115 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
Topline/GB162 boiler 115 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
Topline/GB162 boiler 115 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
Topline/GB162 boiler 115 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
Topline/GB162 boiler 115 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
Topline/GB162 boiler 115 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
Topline/GB162 boiler 115 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
Topline/GB162 boiler 115 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
Topline/GB162 boiler 115 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
Topline/GB162 boiler 115 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
Topline/GB162 boiler 115 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp
Topline/GB162 boiler 115 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas
Topline/GB162 boiler 115 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2
Topline/GB162 boiler 115 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr
Topline/GB162 boiler 115 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork
Topline/GB162 boiler 115 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork
Topline/GB162 boiler 115 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat
Topline/GB162 boiler 115 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower
Topline/GB162 boiler 115 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower
Topline/GB162 boiler 115 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod
Topline/GB162 boiler 115 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow
Topline/GB162 boiler 115 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock
Topline/GB162 boiler 115 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston
Topline/GB162 boiler 115 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff
Topline/GB162 boiler 115 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston
Topline/GB162 boiler 115 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff
Topline/GB162 boiler 115 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon
Topline/GB162 boiler 115 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase
Topline/GB162 boiler 115 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend
Topline/GB162 boiler 115 summertemp summer temperature uint8 (>=0<=30) C True number.boiler_summer_temperature number.boiler_summertemp
Topline/GB162 boiler 115 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode
Topline/GB162 boiler 115 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp
Topline/GB162 boiler 115 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
Topline/GB162 boiler 115 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
Topline/GB162 boiler 115 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
Topline/GB162 boiler 115 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
Topline/GB162 boiler 115 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
Topline/GB162 boiler 115 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
Topline/GB162 boiler 115 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
Topline/GB162 boiler 115 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
Topline/GB162 boiler 115 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
Topline/GB162 boiler 115 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
Topline/GB162 boiler 115 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
Topline/GB162 boiler 115 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
Topline/GB162 boiler 115 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
Topline/GB162 boiler 115 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
Topline/GB162 boiler 115 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
Topline/GB162 boiler 115 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
Topline/GB162 boiler 115 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
Topline/GB162 boiler 115 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
Topline/GB162 boiler 115 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
Topline/GB162 boiler 115 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
Topline/GB162 boiler 115 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
Topline/GB162 boiler 115 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
Topline/GB162 boiler 115 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
Topline/GB162 boiler 115 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
Topline/GB162 boiler 115 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
Topline/GB162 boiler 115 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
Topline/GB162 boiler 115 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
Topline/GB162 boiler 115 meterdhw meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
Topline/GB162 boiler 115 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat
Topline/GB162 boiler 115 gasmeterdhw gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeterdhw
Topline/GB162 boiler 115 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2
Topline/GB162 boiler 115 nrgdhw2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrgdhw2
Topline/GB162 boiler 115 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
Topline/GB162 boiler 115 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
Topline/GB162 boiler 115 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
Topline/GB162 boiler 115 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
Topline/GB162 boiler 115 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
Topline/GB162 boiler 115 seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff
Topline/GB162 boiler 115 seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle
Topline/GB162 boiler 115 solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp
Topline/GB162 boiler 115 type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type
Topline/GB162 boiler 115 comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort
Topline/GB162 boiler 115 comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1
Topline/GB162 boiler 115 flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset
Topline/GB162 boiler 115 chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization
Topline/GB162 boiler 115 maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower
Topline/GB162 boiler 115 maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp
Topline/GB162 boiler 115 circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump
Topline/GB162 boiler 115 chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype
Topline/GB162 boiler 115 hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston
Topline/GB162 boiler 115 hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff
Topline/GB162 boiler 115 disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp
Topline/GB162 boiler 115 circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode
Topline/GB162 boiler 115 circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ
Topline/GB162 boiler 115 curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp
Topline/GB162 boiler 115 curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2
Topline/GB162 boiler 115 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
Topline/GB162 boiler 115 storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1
Topline/GB162 boiler 115 storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2
Topline/GB162 boiler 115 activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated
Topline/GB162 boiler 115 onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime
Topline/GB162 boiler 115 disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting
Topline/GB162 boiler 115 charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging
Topline/GB162 boiler 115 recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging
Topline/GB162 boiler 115 tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok
Topline/GB162 boiler 115 active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active
Topline/GB162 boiler 115 3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve
Topline/GB162 boiler 115 setpumppower set pump power uint8 (>=0<=100) % False sensor.boiler_dhw_set_pump_power sensor.boiler_dhw_setpumppower
Topline/GB162 boiler 115 mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp
Topline/GB162 boiler 115 cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp
Topline/GB162 boiler 115 starts starts uint24 (>=0<=16777213) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts
Topline/GB162 boiler 115 workm active time time (>=0<=16777213) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm
Topline/GB162 boiler 115 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower
Topline/GB162 boiler 115 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal
Topline/GB162 boiler 115 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat
Topline/GB162 boiler 115 nrgdhw energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrgdhw
Cascade MCM10 boiler 121 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
Cascade MCM10 boiler 121 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
Cascade MCM10 boiler 121 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
Cascade MCM10 boiler 121 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
Cascade MCM10 boiler 121 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
Cascade MCM10 boiler 121 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
Cascade MCM10 boiler 121 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
Cascade MCM10 boiler 121 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
Cascade MCM10 boiler 121 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
Cascade MCM10 boiler 121 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
Cascade MCM10 boiler 121 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
Cascade MCM10 boiler 121 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
Cascade MCM10 boiler 121 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
Cascade MCM10 boiler 121 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp
Cascade MCM10 boiler 121 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas
Cascade MCM10 boiler 121 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2
Cascade MCM10 boiler 121 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr
Cascade MCM10 boiler 121 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork
Cascade MCM10 boiler 121 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork
Cascade MCM10 boiler 121 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat
Cascade MCM10 boiler 121 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower
Cascade MCM10 boiler 121 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower
Cascade MCM10 boiler 121 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod
Cascade MCM10 boiler 121 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow
Cascade MCM10 boiler 121 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock
Cascade MCM10 boiler 121 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston
Cascade MCM10 boiler 121 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff
Cascade MCM10 boiler 121 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston
Cascade MCM10 boiler 121 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff
Cascade MCM10 boiler 121 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon
Cascade MCM10 boiler 121 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase
Cascade MCM10 boiler 121 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend
Cascade MCM10 boiler 121 summertemp summer temperature uint8 (>=0<=30) C True number.boiler_summer_temperature number.boiler_summertemp
Cascade MCM10 boiler 121 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode
Cascade MCM10 boiler 121 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp
Cascade MCM10 boiler 121 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
Cascade MCM10 boiler 121 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
Cascade MCM10 boiler 121 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
Cascade MCM10 boiler 121 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
Cascade MCM10 boiler 121 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
Cascade MCM10 boiler 121 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
Cascade MCM10 boiler 121 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
Cascade MCM10 boiler 121 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
Cascade MCM10 boiler 121 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
Cascade MCM10 boiler 121 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
Cascade MCM10 boiler 121 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
Cascade MCM10 boiler 121 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
Cascade MCM10 boiler 121 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
Cascade MCM10 boiler 121 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
Cascade MCM10 boiler 121 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
Cascade MCM10 boiler 121 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
Cascade MCM10 boiler 121 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
Cascade MCM10 boiler 121 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
Cascade MCM10 boiler 121 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
Cascade MCM10 boiler 121 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
Cascade MCM10 boiler 121 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
Cascade MCM10 boiler 121 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
Cascade MCM10 boiler 121 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
Cascade MCM10 boiler 121 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
Cascade MCM10 boiler 121 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
Cascade MCM10 boiler 121 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
Cascade MCM10 boiler 121 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
Cascade MCM10 boiler 121 meterdhw meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
Cascade MCM10 boiler 121 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat
Cascade MCM10 boiler 121 gasmeterdhw gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeterdhw
Cascade MCM10 boiler 121 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2
Cascade MCM10 boiler 121 nrgdhw2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrgdhw2
Cascade MCM10 boiler 121 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
Cascade MCM10 boiler 121 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
Cascade MCM10 boiler 121 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
Cascade MCM10 boiler 121 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
Cascade MCM10 boiler 121 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
Cascade MCM10 boiler 121 seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff
Cascade MCM10 boiler 121 seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle
Cascade MCM10 boiler 121 solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp
Cascade MCM10 boiler 121 type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type
Cascade MCM10 boiler 121 comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort
Cascade MCM10 boiler 121 comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1
Cascade MCM10 boiler 121 flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset
Cascade MCM10 boiler 121 chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization
Cascade MCM10 boiler 121 maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower
Cascade MCM10 boiler 121 maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp
Cascade MCM10 boiler 121 circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump
Cascade MCM10 boiler 121 chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype
Cascade MCM10 boiler 121 hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston
Cascade MCM10 boiler 121 hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff
Cascade MCM10 boiler 121 disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp
Cascade MCM10 boiler 121 circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode
Cascade MCM10 boiler 121 circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ
Cascade MCM10 boiler 121 curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp
Cascade MCM10 boiler 121 curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2
Cascade MCM10 boiler 121 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
Cascade MCM10 boiler 121 storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1
Cascade MCM10 boiler 121 storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2
Cascade MCM10 boiler 121 activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated
Cascade MCM10 boiler 121 onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime
Cascade MCM10 boiler 121 disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting
Cascade MCM10 boiler 121 charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging
Cascade MCM10 boiler 121 recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging
Cascade MCM10 boiler 121 tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok
Cascade MCM10 boiler 121 active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active
Cascade MCM10 boiler 121 3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve
Cascade MCM10 boiler 121 setpumppower set pump power uint8 (>=0<=100) % False sensor.boiler_dhw_set_pump_power sensor.boiler_dhw_setpumppower
Cascade MCM10 boiler 121 mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp
Cascade MCM10 boiler 121 cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp
Cascade MCM10 boiler 121 starts starts uint24 (>=0<=16777213) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts
Cascade MCM10 boiler 121 workm active time time (>=0<=16777213) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm
Cascade MCM10 boiler 121 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower
Cascade MCM10 boiler 121 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal
Cascade MCM10 boiler 121 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat
Cascade MCM10 boiler 121 nrgdhw energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrgdhw
Proline boiler 122 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
Proline boiler 122 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
Proline boiler 122 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
Proline boiler 122 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
Proline boiler 122 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
Proline boiler 122 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
Proline boiler 122 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
Proline boiler 122 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
Proline boiler 122 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
Proline boiler 122 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
Proline boiler 122 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
Proline boiler 122 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
Proline boiler 122 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
Proline boiler 122 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp
Proline boiler 122 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas
Proline boiler 122 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2
Proline boiler 122 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr
Proline boiler 122 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork
Proline boiler 122 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork
Proline boiler 122 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat
Proline boiler 122 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower
Proline boiler 122 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower
Proline boiler 122 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod
Proline boiler 122 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow
Proline boiler 122 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock
Proline boiler 122 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston
Proline boiler 122 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff
Proline boiler 122 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston
Proline boiler 122 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff
Proline boiler 122 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon
Proline boiler 122 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase
Proline boiler 122 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend
Proline boiler 122 summertemp summer temperature uint8 (>=0<=30) C True number.boiler_summer_temperature number.boiler_summertemp
Proline boiler 122 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode
Proline boiler 122 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp
Proline boiler 122 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
Proline boiler 122 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
Proline boiler 122 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
Proline boiler 122 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
Proline boiler 122 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
Proline boiler 122 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
Proline boiler 122 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
Proline boiler 122 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
Proline boiler 122 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
Proline boiler 122 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
Proline boiler 122 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
Proline boiler 122 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
Proline boiler 122 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
Proline boiler 122 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
Proline boiler 122 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
Proline boiler 122 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
Proline boiler 122 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
Proline boiler 122 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
Proline boiler 122 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
Proline boiler 122 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
Proline boiler 122 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
Proline boiler 122 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
Proline boiler 122 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
Proline boiler 122 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
Proline boiler 122 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
Proline boiler 122 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
Proline boiler 122 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
Proline boiler 122 meterdhw meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
Proline boiler 122 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat
Proline boiler 122 gasmeterdhw gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeterdhw
Proline boiler 122 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2
Proline boiler 122 nrgdhw2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrgdhw2
Proline boiler 122 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
Proline boiler 122 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
Proline boiler 122 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
Proline boiler 122 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
Proline boiler 122 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
Proline boiler 122 seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff
Proline boiler 122 seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle
Proline boiler 122 solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp
Proline boiler 122 type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type
Proline boiler 122 comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort
Proline boiler 122 comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1
Proline boiler 122 flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset
Proline boiler 122 chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization
Proline boiler 122 maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower
Proline boiler 122 maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp
Proline boiler 122 circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump
Proline boiler 122 chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype
Proline boiler 122 hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston
Proline boiler 122 hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff
Proline boiler 122 disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp
Proline boiler 122 circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode
Proline boiler 122 circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ
Proline boiler 122 curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp
Proline boiler 122 curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2
Proline boiler 122 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
Proline boiler 122 storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1
Proline boiler 122 storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2
Proline boiler 122 activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated
Proline boiler 122 onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime
Proline boiler 122 disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting
Proline boiler 122 charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging
Proline boiler 122 recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging
Proline boiler 122 tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok
Proline boiler 122 active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active
Proline boiler 122 3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve
Proline boiler 122 setpumppower set pump power uint8 (>=0<=100) % False sensor.boiler_dhw_set_pump_power sensor.boiler_dhw_setpumppower
Proline boiler 122 mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp
Proline boiler 122 cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp
Proline boiler 122 starts starts uint24 (>=0<=16777213) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts
Proline boiler 122 workm active time time (>=0<=16777213) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm
Proline boiler 122 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower
Proline boiler 122 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal
Proline boiler 122 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat
Proline boiler 122 nrgdhw energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrgdhw
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 summertemp summer temperature uint8 (>=0<=30) C True number.boiler_summer_temperature number.boiler_summertemp
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 meterdhw meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 gasmeterdhw gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeterdhw
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 nrgdhw2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrgdhw2
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 setpumppower set pump power uint8 (>=0<=100) % False sensor.boiler_dhw_set_pump_power sensor.boiler_dhw_setpumppower
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 starts starts uint24 (>=0<=16777213) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 workm active time time (>=0<=16777213) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat
GBx72/Trendline/Cerapur/Greenstar Si boiler 123 nrgdhw energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrgdhw
GB212 boiler 131 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
GB212 boiler 131 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
GB212 boiler 131 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
GB212 boiler 131 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
GB212 boiler 131 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
GB212 boiler 131 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
GB212 boiler 131 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
GB212 boiler 131 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
GB212 boiler 131 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
GB212 boiler 131 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
GB212 boiler 131 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
GB212 boiler 131 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
GB212 boiler 131 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
GB212 boiler 131 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp
GB212 boiler 131 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas
GB212 boiler 131 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2
GB212 boiler 131 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr
GB212 boiler 131 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork
GB212 boiler 131 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork
GB212 boiler 131 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat
GB212 boiler 131 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower
GB212 boiler 131 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower
GB212 boiler 131 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod
GB212 boiler 131 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow
GB212 boiler 131 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock
GB212 boiler 131 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston
GB212 boiler 131 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff
GB212 boiler 131 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston
GB212 boiler 131 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff
GB212 boiler 131 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon
GB212 boiler 131 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase
GB212 boiler 131 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend
GB212 boiler 131 summertemp summer temperature uint8 (>=0<=30) C True number.boiler_summer_temperature number.boiler_summertemp
GB212 boiler 131 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode
GB212 boiler 131 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp
GB212 boiler 131 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
GB212 boiler 131 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
GB212 boiler 131 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
GB212 boiler 131 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
GB212 boiler 131 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
GB212 boiler 131 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
GB212 boiler 131 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
GB212 boiler 131 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
GB212 boiler 131 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
GB212 boiler 131 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
GB212 boiler 131 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
GB212 boiler 131 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
GB212 boiler 131 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
GB212 boiler 131 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
GB212 boiler 131 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
GB212 boiler 131 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
GB212 boiler 131 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
GB212 boiler 131 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
GB212 boiler 131 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
GB212 boiler 131 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
GB212 boiler 131 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
GB212 boiler 131 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
GB212 boiler 131 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
GB212 boiler 131 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
GB212 boiler 131 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
GB212 boiler 131 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
GB212 boiler 131 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
GB212 boiler 131 meterdhw meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
GB212 boiler 131 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat
GB212 boiler 131 gasmeterdhw gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeterdhw
GB212 boiler 131 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2
GB212 boiler 131 nrgdhw2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrgdhw2
GB212 boiler 131 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
GB212 boiler 131 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
GB212 boiler 131 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
GB212 boiler 131 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
GB212 boiler 131 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
GB212 boiler 131 seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff
GB212 boiler 131 seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle
GB212 boiler 131 solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp
GB212 boiler 131 type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type
GB212 boiler 131 comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort
GB212 boiler 131 comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1
GB212 boiler 131 flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset
GB212 boiler 131 chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization
GB212 boiler 131 maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower
GB212 boiler 131 maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp
GB212 boiler 131 circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump
GB212 boiler 131 chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype
GB212 boiler 131 hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston
GB212 boiler 131 hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff
GB212 boiler 131 disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp
GB212 boiler 131 circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode
GB212 boiler 131 circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ
GB212 boiler 131 curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp
GB212 boiler 131 curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2
GB212 boiler 131 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
GB212 boiler 131 storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1
GB212 boiler 131 storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2
GB212 boiler 131 activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated
GB212 boiler 131 onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime
GB212 boiler 131 disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting
GB212 boiler 131 charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging
GB212 boiler 131 recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging
GB212 boiler 131 tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok
GB212 boiler 131 active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active
GB212 boiler 131 3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve
GB212 boiler 131 setpumppower set pump power uint8 (>=0<=100) % False sensor.boiler_dhw_set_pump_power sensor.boiler_dhw_setpumppower
GB212 boiler 131 mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp
GB212 boiler 131 cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp
GB212 boiler 131 starts starts uint24 (>=0<=16777213) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts
GB212 boiler 131 workm active time time (>=0<=16777213) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm
GB212 boiler 131 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower
GB212 boiler 131 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal
GB212 boiler 131 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat
GB212 boiler 131 nrgdhw energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrgdhw
GC7000F boiler 132 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
GC7000F boiler 132 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
GC7000F boiler 132 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
GC7000F boiler 132 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
GC7000F boiler 132 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
GC7000F boiler 132 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
GC7000F boiler 132 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
GC7000F boiler 132 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
GC7000F boiler 132 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
GC7000F boiler 132 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
GC7000F boiler 132 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
GC7000F boiler 132 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
GC7000F boiler 132 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
GC7000F boiler 132 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp
GC7000F boiler 132 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas
GC7000F boiler 132 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2
GC7000F boiler 132 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr
GC7000F boiler 132 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork
GC7000F boiler 132 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork
GC7000F boiler 132 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat
GC7000F boiler 132 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower
GC7000F boiler 132 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower
GC7000F boiler 132 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod
GC7000F boiler 132 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow
GC7000F boiler 132 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock
GC7000F boiler 132 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston
GC7000F boiler 132 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff
GC7000F boiler 132 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston
GC7000F boiler 132 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff
GC7000F boiler 132 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon
GC7000F boiler 132 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase
GC7000F boiler 132 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend
GC7000F boiler 132 summertemp summer temperature uint8 (>=0<=30) C True number.boiler_summer_temperature number.boiler_summertemp
GC7000F boiler 132 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode
GC7000F boiler 132 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp
GC7000F boiler 132 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
GC7000F boiler 132 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
GC7000F boiler 132 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
GC7000F boiler 132 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
GC7000F boiler 132 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
GC7000F boiler 132 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
GC7000F boiler 132 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
GC7000F boiler 132 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
GC7000F boiler 132 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
GC7000F boiler 132 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
GC7000F boiler 132 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
GC7000F boiler 132 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
GC7000F boiler 132 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
GC7000F boiler 132 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
GC7000F boiler 132 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
GC7000F boiler 132 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
GC7000F boiler 132 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
GC7000F boiler 132 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
GC7000F boiler 132 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
GC7000F boiler 132 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
GC7000F boiler 132 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
GC7000F boiler 132 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
GC7000F boiler 132 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
GC7000F boiler 132 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
GC7000F boiler 132 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
GC7000F boiler 132 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
GC7000F boiler 132 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
GC7000F boiler 132 meterdhw meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
GC7000F boiler 132 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat
GC7000F boiler 132 gasmeterdhw gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeterdhw
GC7000F boiler 132 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2
GC7000F boiler 132 nrgdhw2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrgdhw2
GC7000F boiler 132 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
GC7000F boiler 132 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
GC7000F boiler 132 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
GC7000F boiler 132 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
GC7000F boiler 132 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
GC7000F boiler 132 seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff
GC7000F boiler 132 seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle
GC7000F boiler 132 solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp
GC7000F boiler 132 type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type
GC7000F boiler 132 comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort
GC7000F boiler 132 comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1
GC7000F boiler 132 flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset
GC7000F boiler 132 chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization
GC7000F boiler 132 maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower
GC7000F boiler 132 maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp
GC7000F boiler 132 circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump
GC7000F boiler 132 chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype
GC7000F boiler 132 hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston
GC7000F boiler 132 hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff
GC7000F boiler 132 disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp
GC7000F boiler 132 circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode
GC7000F boiler 132 circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ
GC7000F boiler 132 curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp
GC7000F boiler 132 curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2
GC7000F boiler 132 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
GC7000F boiler 132 storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1
GC7000F boiler 132 storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2
GC7000F boiler 132 activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated
GC7000F boiler 132 onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime
GC7000F boiler 132 disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting
GC7000F boiler 132 charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging
GC7000F boiler 132 recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging
GC7000F boiler 132 tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok
GC7000F boiler 132 active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active
GC7000F boiler 132 3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve
GC7000F boiler 132 setpumppower set pump power uint8 (>=0<=100) % False sensor.boiler_dhw_set_pump_power sensor.boiler_dhw_setpumppower
GC7000F boiler 132 mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp
GC7000F boiler 132 cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp
GC7000F boiler 132 starts starts uint24 (>=0<=16777213) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts
GC7000F boiler 132 workm active time time (>=0<=16777213) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm
GC7000F boiler 132 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower
GC7000F boiler 132 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal
GC7000F boiler 132 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat
GC7000F boiler 132 nrgdhw energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrgdhw
Logano GB125/KB195i/Logamatic MC110 boiler 133 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
Logano GB125/KB195i/Logamatic MC110 boiler 133 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
Logano GB125/KB195i/Logamatic MC110 boiler 133 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
Logano GB125/KB195i/Logamatic MC110 boiler 133 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
Logano GB125/KB195i/Logamatic MC110 boiler 133 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
Logano GB125/KB195i/Logamatic MC110 boiler 133 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
Logano GB125/KB195i/Logamatic MC110 boiler 133 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
Logano GB125/KB195i/Logamatic MC110 boiler 133 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
Logano GB125/KB195i/Logamatic MC110 boiler 133 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
Logano GB125/KB195i/Logamatic MC110 boiler 133 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
Logano GB125/KB195i/Logamatic MC110 boiler 133 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
Logano GB125/KB195i/Logamatic MC110 boiler 133 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
Logano GB125/KB195i/Logamatic MC110 boiler 133 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
Logano GB125/KB195i/Logamatic MC110 boiler 133 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp
Logano GB125/KB195i/Logamatic MC110 boiler 133 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas
Logano GB125/KB195i/Logamatic MC110 boiler 133 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2
Logano GB125/KB195i/Logamatic MC110 boiler 133 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr
Logano GB125/KB195i/Logamatic MC110 boiler 133 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork
Logano GB125/KB195i/Logamatic MC110 boiler 133 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork
Logano GB125/KB195i/Logamatic MC110 boiler 133 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat
Logano GB125/KB195i/Logamatic MC110 boiler 133 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower
Logano GB125/KB195i/Logamatic MC110 boiler 133 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower
Logano GB125/KB195i/Logamatic MC110 boiler 133 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod
Logano GB125/KB195i/Logamatic MC110 boiler 133 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow
Logano GB125/KB195i/Logamatic MC110 boiler 133 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock
Logano GB125/KB195i/Logamatic MC110 boiler 133 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston
Logano GB125/KB195i/Logamatic MC110 boiler 133 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff
Logano GB125/KB195i/Logamatic MC110 boiler 133 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston
Logano GB125/KB195i/Logamatic MC110 boiler 133 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff
Logano GB125/KB195i/Logamatic MC110 boiler 133 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon
Logano GB125/KB195i/Logamatic MC110 boiler 133 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase
Logano GB125/KB195i/Logamatic MC110 boiler 133 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend
Logano GB125/KB195i/Logamatic MC110 boiler 133 summertemp summer temperature uint8 (>=0<=30) C True number.boiler_summer_temperature number.boiler_summertemp
Logano GB125/KB195i/Logamatic MC110 boiler 133 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode
Logano GB125/KB195i/Logamatic MC110 boiler 133 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp
Logano GB125/KB195i/Logamatic MC110 boiler 133 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
Logano GB125/KB195i/Logamatic MC110 boiler 133 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
Logano GB125/KB195i/Logamatic MC110 boiler 133 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
Logano GB125/KB195i/Logamatic MC110 boiler 133 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
Logano GB125/KB195i/Logamatic MC110 boiler 133 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
Logano GB125/KB195i/Logamatic MC110 boiler 133 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
Logano GB125/KB195i/Logamatic MC110 boiler 133 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
Logano GB125/KB195i/Logamatic MC110 boiler 133 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
Logano GB125/KB195i/Logamatic MC110 boiler 133 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
Logano GB125/KB195i/Logamatic MC110 boiler 133 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
Logano GB125/KB195i/Logamatic MC110 boiler 133 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
Logano GB125/KB195i/Logamatic MC110 boiler 133 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
Logano GB125/KB195i/Logamatic MC110 boiler 133 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
Logano GB125/KB195i/Logamatic MC110 boiler 133 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
Logano GB125/KB195i/Logamatic MC110 boiler 133 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
Logano GB125/KB195i/Logamatic MC110 boiler 133 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
Logano GB125/KB195i/Logamatic MC110 boiler 133 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
Logano GB125/KB195i/Logamatic MC110 boiler 133 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
Logano GB125/KB195i/Logamatic MC110 boiler 133 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
Logano GB125/KB195i/Logamatic MC110 boiler 133 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
Logano GB125/KB195i/Logamatic MC110 boiler 133 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
Logano GB125/KB195i/Logamatic MC110 boiler 133 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
Logano GB125/KB195i/Logamatic MC110 boiler 133 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
Logano GB125/KB195i/Logamatic MC110 boiler 133 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
Logano GB125/KB195i/Logamatic MC110 boiler 133 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
Logano GB125/KB195i/Logamatic MC110 boiler 133 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
Logano GB125/KB195i/Logamatic MC110 boiler 133 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
Logano GB125/KB195i/Logamatic MC110 boiler 133 meterdhw meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
Logano GB125/KB195i/Logamatic MC110 boiler 133 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat
Logano GB125/KB195i/Logamatic MC110 boiler 133 gasmeterdhw gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeterdhw
Logano GB125/KB195i/Logamatic MC110 boiler 133 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2
Logano GB125/KB195i/Logamatic MC110 boiler 133 nrgdhw2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrgdhw2
Logano GB125/KB195i/Logamatic MC110 boiler 133 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
Logano GB125/KB195i/Logamatic MC110 boiler 133 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
Logano GB125/KB195i/Logamatic MC110 boiler 133 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
Logano GB125/KB195i/Logamatic MC110 boiler 133 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
Logano GB125/KB195i/Logamatic MC110 boiler 133 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
Logano GB125/KB195i/Logamatic MC110 boiler 133 seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff
Logano GB125/KB195i/Logamatic MC110 boiler 133 seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle
Logano GB125/KB195i/Logamatic MC110 boiler 133 solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp
Logano GB125/KB195i/Logamatic MC110 boiler 133 type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type
Logano GB125/KB195i/Logamatic MC110 boiler 133 comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort
Logano GB125/KB195i/Logamatic MC110 boiler 133 comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1
Logano GB125/KB195i/Logamatic MC110 boiler 133 flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset
Logano GB125/KB195i/Logamatic MC110 boiler 133 chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization
Logano GB125/KB195i/Logamatic MC110 boiler 133 maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower
Logano GB125/KB195i/Logamatic MC110 boiler 133 maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp
Logano GB125/KB195i/Logamatic MC110 boiler 133 circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump
Logano GB125/KB195i/Logamatic MC110 boiler 133 chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype
Logano GB125/KB195i/Logamatic MC110 boiler 133 hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston
Logano GB125/KB195i/Logamatic MC110 boiler 133 hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff
Logano GB125/KB195i/Logamatic MC110 boiler 133 disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp
Logano GB125/KB195i/Logamatic MC110 boiler 133 circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode
Logano GB125/KB195i/Logamatic MC110 boiler 133 circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ
Logano GB125/KB195i/Logamatic MC110 boiler 133 curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp
Logano GB125/KB195i/Logamatic MC110 boiler 133 curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2
Logano GB125/KB195i/Logamatic MC110 boiler 133 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
Logano GB125/KB195i/Logamatic MC110 boiler 133 storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1
Logano GB125/KB195i/Logamatic MC110 boiler 133 storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2
Logano GB125/KB195i/Logamatic MC110 boiler 133 activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated
Logano GB125/KB195i/Logamatic MC110 boiler 133 onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime
Logano GB125/KB195i/Logamatic MC110 boiler 133 disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting
Logano GB125/KB195i/Logamatic MC110 boiler 133 charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging
Logano GB125/KB195i/Logamatic MC110 boiler 133 recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging
Logano GB125/KB195i/Logamatic MC110 boiler 133 tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok
Logano GB125/KB195i/Logamatic MC110 boiler 133 active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active
Logano GB125/KB195i/Logamatic MC110 boiler 133 3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve
Logano GB125/KB195i/Logamatic MC110 boiler 133 setpumppower set pump power uint8 (>=0<=100) % False sensor.boiler_dhw_set_pump_power sensor.boiler_dhw_setpumppower
Logano GB125/KB195i/Logamatic MC110 boiler 133 mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp
Logano GB125/KB195i/Logamatic MC110 boiler 133 cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp
Logano GB125/KB195i/Logamatic MC110 boiler 133 starts starts uint24 (>=0<=16777213) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts
Logano GB125/KB195i/Logamatic MC110 boiler 133 workm active time time (>=0<=16777213) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm
Logano GB125/KB195i/Logamatic MC110 boiler 133 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower
Logano GB125/KB195i/Logamatic MC110 boiler 133 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal
Logano GB125/KB195i/Logamatic MC110 boiler 133 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat
Logano GB125/KB195i/Logamatic MC110 boiler 133 nrgdhw energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrgdhw
Greenstar 30Ri Compact boiler 154 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
Greenstar 30Ri Compact boiler 154 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
Greenstar 30Ri Compact boiler 154 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
Greenstar 30Ri Compact boiler 154 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
Greenstar 30Ri Compact boiler 154 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
Greenstar 30Ri Compact boiler 154 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
Greenstar 30Ri Compact boiler 154 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
Greenstar 30Ri Compact boiler 154 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
Greenstar 30Ri Compact boiler 154 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
Greenstar 30Ri Compact boiler 154 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
Greenstar 30Ri Compact boiler 154 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
Greenstar 30Ri Compact boiler 154 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
Greenstar 30Ri Compact boiler 154 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
Greenstar 30Ri Compact boiler 154 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp
Greenstar 30Ri Compact boiler 154 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas
Greenstar 30Ri Compact boiler 154 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2
Greenstar 30Ri Compact boiler 154 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr
Greenstar 30Ri Compact boiler 154 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork
Greenstar 30Ri Compact boiler 154 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork
Greenstar 30Ri Compact boiler 154 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat
Greenstar 30Ri Compact boiler 154 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower
Greenstar 30Ri Compact boiler 154 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower
Greenstar 30Ri Compact boiler 154 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod
Greenstar 30Ri Compact boiler 154 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow
Greenstar 30Ri Compact boiler 154 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock
Greenstar 30Ri Compact boiler 154 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston
Greenstar 30Ri Compact boiler 154 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff
Greenstar 30Ri Compact boiler 154 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston
Greenstar 30Ri Compact boiler 154 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff
Greenstar 30Ri Compact boiler 154 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon
Greenstar 30Ri Compact boiler 154 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase
Greenstar 30Ri Compact boiler 154 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend
Greenstar 30Ri Compact boiler 154 summertemp summer temperature uint8 (>=0<=30) C True number.boiler_summer_temperature number.boiler_summertemp
Greenstar 30Ri Compact boiler 154 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode
Greenstar 30Ri Compact boiler 154 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp
Greenstar 30Ri Compact boiler 154 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
Greenstar 30Ri Compact boiler 154 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
Greenstar 30Ri Compact boiler 154 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
Greenstar 30Ri Compact boiler 154 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
Greenstar 30Ri Compact boiler 154 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
Greenstar 30Ri Compact boiler 154 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
Greenstar 30Ri Compact boiler 154 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
Greenstar 30Ri Compact boiler 154 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
Greenstar 30Ri Compact boiler 154 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
Greenstar 30Ri Compact boiler 154 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
Greenstar 30Ri Compact boiler 154 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
Greenstar 30Ri Compact boiler 154 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
Greenstar 30Ri Compact boiler 154 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
Greenstar 30Ri Compact boiler 154 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
Greenstar 30Ri Compact boiler 154 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
Greenstar 30Ri Compact boiler 154 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
Greenstar 30Ri Compact boiler 154 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
Greenstar 30Ri Compact boiler 154 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
Greenstar 30Ri Compact boiler 154 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
Greenstar 30Ri Compact boiler 154 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
Greenstar 30Ri Compact boiler 154 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
Greenstar 30Ri Compact boiler 154 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
Greenstar 30Ri Compact boiler 154 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
Greenstar 30Ri Compact boiler 154 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
Greenstar 30Ri Compact boiler 154 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
Greenstar 30Ri Compact boiler 154 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
Greenstar 30Ri Compact boiler 154 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
Greenstar 30Ri Compact boiler 154 meterdhw meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
Greenstar 30Ri Compact boiler 154 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat
Greenstar 30Ri Compact boiler 154 gasmeterdhw gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeterdhw
Greenstar 30Ri Compact boiler 154 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2
Greenstar 30Ri Compact boiler 154 nrgdhw2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrgdhw2
Greenstar 30Ri Compact boiler 154 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
Greenstar 30Ri Compact boiler 154 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
Greenstar 30Ri Compact boiler 154 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
Greenstar 30Ri Compact boiler 154 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
Greenstar 30Ri Compact boiler 154 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
Greenstar 30Ri Compact boiler 154 seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff
Greenstar 30Ri Compact boiler 154 seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle
Greenstar 30Ri Compact boiler 154 solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp
Greenstar 30Ri Compact boiler 154 type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type
Greenstar 30Ri Compact boiler 154 comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort
Greenstar 30Ri Compact boiler 154 comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1
Greenstar 30Ri Compact boiler 154 flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset
Greenstar 30Ri Compact boiler 154 chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization
Greenstar 30Ri Compact boiler 154 maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower
Greenstar 30Ri Compact boiler 154 maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp
Greenstar 30Ri Compact boiler 154 circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump
Greenstar 30Ri Compact boiler 154 chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype
Greenstar 30Ri Compact boiler 154 hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston
Greenstar 30Ri Compact boiler 154 hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff
Greenstar 30Ri Compact boiler 154 disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp
Greenstar 30Ri Compact boiler 154 circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode
Greenstar 30Ri Compact boiler 154 circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ
Greenstar 30Ri Compact boiler 154 curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp
Greenstar 30Ri Compact boiler 154 curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2
Greenstar 30Ri Compact boiler 154 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
Greenstar 30Ri Compact boiler 154 storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1
Greenstar 30Ri Compact boiler 154 storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2
Greenstar 30Ri Compact boiler 154 activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated
Greenstar 30Ri Compact boiler 154 onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime
Greenstar 30Ri Compact boiler 154 disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting
Greenstar 30Ri Compact boiler 154 charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging
Greenstar 30Ri Compact boiler 154 recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging
Greenstar 30Ri Compact boiler 154 tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok
Greenstar 30Ri Compact boiler 154 active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active
Greenstar 30Ri Compact boiler 154 3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve
Greenstar 30Ri Compact boiler 154 setpumppower set pump power uint8 (>=0<=100) % False sensor.boiler_dhw_set_pump_power sensor.boiler_dhw_setpumppower
Greenstar 30Ri Compact boiler 154 mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp
Greenstar 30Ri Compact boiler 154 cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp
Greenstar 30Ri Compact boiler 154 starts starts uint24 (>=0<=16777213) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts
Greenstar 30Ri Compact boiler 154 workm active time time (>=0<=16777213) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm
Greenstar 30Ri Compact boiler 154 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower
Greenstar 30Ri Compact boiler 154 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal
Greenstar 30Ri Compact boiler 154 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat
Greenstar 30Ri Compact boiler 154 nrgdhw energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrgdhw
Cerapur Aero boiler 167 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
Cerapur Aero boiler 167 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
Cerapur Aero boiler 167 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
Cerapur Aero boiler 167 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
Cerapur Aero boiler 167 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
Cerapur Aero boiler 167 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
Cerapur Aero boiler 167 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
Cerapur Aero boiler 167 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
Cerapur Aero boiler 167 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
Cerapur Aero boiler 167 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
Cerapur Aero boiler 167 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
Cerapur Aero boiler 167 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
Cerapur Aero boiler 167 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
Cerapur Aero boiler 167 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp
Cerapur Aero boiler 167 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas
Cerapur Aero boiler 167 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2
Cerapur Aero boiler 167 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr
Cerapur Aero boiler 167 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork
Cerapur Aero boiler 167 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork
Cerapur Aero boiler 167 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat
Cerapur Aero boiler 167 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower
Cerapur Aero boiler 167 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower
Cerapur Aero boiler 167 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod
Cerapur Aero boiler 167 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow
Cerapur Aero boiler 167 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock
Cerapur Aero boiler 167 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston
Cerapur Aero boiler 167 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff
Cerapur Aero boiler 167 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston
Cerapur Aero boiler 167 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff
Cerapur Aero boiler 167 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon
Cerapur Aero boiler 167 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase
Cerapur Aero boiler 167 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend
Cerapur Aero boiler 167 summertemp summer temperature uint8 (>=0<=30) C True number.boiler_summer_temperature number.boiler_summertemp
Cerapur Aero boiler 167 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode
Cerapur Aero boiler 167 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp
Cerapur Aero boiler 167 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
Cerapur Aero boiler 167 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
Cerapur Aero boiler 167 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
Cerapur Aero boiler 167 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
Cerapur Aero boiler 167 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
Cerapur Aero boiler 167 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
Cerapur Aero boiler 167 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
Cerapur Aero boiler 167 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
Cerapur Aero boiler 167 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
Cerapur Aero boiler 167 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
Cerapur Aero boiler 167 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
Cerapur Aero boiler 167 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
Cerapur Aero boiler 167 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
Cerapur Aero boiler 167 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
Cerapur Aero boiler 167 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
Cerapur Aero boiler 167 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
Cerapur Aero boiler 167 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
Cerapur Aero boiler 167 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
Cerapur Aero boiler 167 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
Cerapur Aero boiler 167 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
Cerapur Aero boiler 167 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
Cerapur Aero boiler 167 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
Cerapur Aero boiler 167 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
Cerapur Aero boiler 167 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
Cerapur Aero boiler 167 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
Cerapur Aero boiler 167 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
Cerapur Aero boiler 167 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
Cerapur Aero boiler 167 meterdhw meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
Cerapur Aero boiler 167 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat
Cerapur Aero boiler 167 gasmeterdhw gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeterdhw
Cerapur Aero boiler 167 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2
Cerapur Aero boiler 167 nrgdhw2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrgdhw2
Cerapur Aero boiler 167 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
Cerapur Aero boiler 167 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
Cerapur Aero boiler 167 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
Cerapur Aero boiler 167 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
Cerapur Aero boiler 167 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
Cerapur Aero boiler 167 seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff
Cerapur Aero boiler 167 seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle
Cerapur Aero boiler 167 solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp
Cerapur Aero boiler 167 type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type
Cerapur Aero boiler 167 comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort
Cerapur Aero boiler 167 comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1
Cerapur Aero boiler 167 flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset
Cerapur Aero boiler 167 chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization
Cerapur Aero boiler 167 maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower
Cerapur Aero boiler 167 maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp
Cerapur Aero boiler 167 circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump
Cerapur Aero boiler 167 chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype
Cerapur Aero boiler 167 hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston
Cerapur Aero boiler 167 hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff
Cerapur Aero boiler 167 disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp
Cerapur Aero boiler 167 circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode
Cerapur Aero boiler 167 circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ
Cerapur Aero boiler 167 curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp
Cerapur Aero boiler 167 curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2
Cerapur Aero boiler 167 curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow
Cerapur Aero boiler 167 storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1
Cerapur Aero boiler 167 storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2
Cerapur Aero boiler 167 activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated
Cerapur Aero boiler 167 onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime
Cerapur Aero boiler 167 disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting
Cerapur Aero boiler 167 charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging
Cerapur Aero boiler 167 recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging
Cerapur Aero boiler 167 tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok
Cerapur Aero boiler 167 active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active
Cerapur Aero boiler 167 3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve
Cerapur Aero boiler 167 setpumppower set pump power uint8 (>=0<=100) % False sensor.boiler_dhw_set_pump_power sensor.boiler_dhw_setpumppower
Cerapur Aero boiler 167 mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp
Cerapur Aero boiler 167 cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp
Cerapur Aero boiler 167 starts starts uint24 (>=0<=16777213) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts
Cerapur Aero boiler 167 workm active time time (>=0<=16777213) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm
Cerapur Aero boiler 167 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower
Cerapur Aero boiler 167 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal
Cerapur Aero boiler 167 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat
Cerapur Aero boiler 167 nrgdhw energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrgdhw
Hybrid Heatpump boiler 168 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset
Hybrid Heatpump boiler 168 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff
Hybrid Heatpump boiler 168 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive
Hybrid Heatpump boiler 168 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive
Hybrid Heatpump boiler 168 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp
Hybrid Heatpump boiler 168 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod
Hybrid Heatpump boiler 168 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp
Hybrid Heatpump boiler 168 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp
Hybrid Heatpump boiler 168 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp
Hybrid Heatpump boiler 168 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp
Hybrid Heatpump boiler 168 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress
Hybrid Heatpump boiler 168 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp
Hybrid Heatpump boiler 168 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp
Hybrid Heatpump boiler 168 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp
Hybrid Heatpump boiler 168 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas
Hybrid Heatpump boiler 168 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2
Hybrid Heatpump boiler 168 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr
Hybrid Heatpump boiler 168 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork
Hybrid Heatpump boiler 168 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork
Hybrid Heatpump boiler 168 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat
Hybrid Heatpump boiler 168 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower
Hybrid Heatpump boiler 168 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower
Hybrid Heatpump boiler 168 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod
Hybrid Heatpump boiler 168 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow
Hybrid Heatpump boiler 168 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock
Hybrid Heatpump boiler 168 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston
Hybrid Heatpump boiler 168 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff
Hybrid Heatpump boiler 168 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston
Hybrid Heatpump boiler 168 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff
Hybrid Heatpump boiler 168 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon
Hybrid Heatpump boiler 168 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase
Hybrid Heatpump boiler 168 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend
Hybrid Heatpump boiler 168 summertemp summer temperature uint8 (>=0<=30) C True number.boiler_summer_temperature number.boiler_summertemp
Hybrid Heatpump boiler 168 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode
Hybrid Heatpump boiler 168 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp
Hybrid Heatpump boiler 168 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated
Hybrid Heatpump boiler 168 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp
Hybrid Heatpump boiler 168 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump
Hybrid Heatpump boiler 168 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax
Hybrid Heatpump boiler 168 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin
Hybrid Heatpump boiler 168 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode
Hybrid Heatpump boiler 168 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay
Hybrid Heatpump boiler 168 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.boiler_set_flow_temperature sensor.boiler_setflowtemp
Hybrid Heatpump boiler 168 setburnpow burner set power uint8 (>=0<=100) % False sensor.boiler_burner_set_power sensor.boiler_setburnpow
Hybrid Heatpump boiler 168 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow
Hybrid Heatpump boiler 168 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow
Hybrid Heatpump boiler 168 burnstarts burner starts uint24 (>=0<=16777213) False sensor.boiler_burner_starts sensor.boiler_burnstarts
Hybrid Heatpump boiler 168 burnworkmin total burner operating time time (>=0<=16777213) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin
Hybrid Heatpump boiler 168 burn2workmin burner stage 2 operating time time (>=0<=16777213) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin
Hybrid Heatpump boiler 168 heatworkmin total heat operating time time (>=0<=16777213) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin
Hybrid Heatpump boiler 168 heatstarts burner starts heating uint24 (>=0<=16777213) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts
Hybrid Heatpump boiler 168 ubauptime total UBA operating time time (>=0<=16777213) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime
Hybrid Heatpump boiler 168 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode
Hybrid Heatpump boiler 168 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode
Hybrid Heatpump boiler 168 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber
Hybrid Heatpump boiler 168 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage
Hybrid Heatpump boiler 168 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance
Hybrid Heatpump boiler 168 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime
Hybrid Heatpump boiler 168 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate
Hybrid Heatpump boiler 168 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops
Hybrid Heatpump boiler 168 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp
Hybrid Heatpump boiler 168 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat
Hybrid Heatpump boiler 168 meterdhw meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meterdhw
Hybrid Heatpump boiler 168 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat
Hybrid Heatpump boiler 168 gasmeterdhw gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeterdhw
Hybrid Heatpump boiler 168 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2
Hybrid Heatpump boiler 168 nrgdhw2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrgdhw2
Hybrid Heatpump boiler 168 tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated
Hybrid Heatpump boiler 168 settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp
Hybrid Heatpump boiler 168 seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp
Hybrid Heatpump boiler 168 seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow
Hybrid Heatpump boiler 168 tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus
Hybrid Heatpump boile