All Devices and Entities
please read
Make sure you have read and understood the Disclaimer before sending ambiguous messages to your EMS bus as you could cause serious damage to your equipment.
Most Bosch branded boilers that support the Logamatic EMS bus protocols work with this design. This includes Nefit, Buderus, Worcester, Junkers and Sieger (all copyrighted).
EMS devices are being constantly added to the database on each new release.
The following device types are supported:
- boiler
- thermostat
- heatpump
- heatsource
- solar
- connect
- mixer
- controller
- switch
- gateway
- alert
- pump
All EMS Telegrams~
telegram_type_id | name | is_fetched | is_cmd |
---|---|---|---|
0x04 | UBAFactory | fetched | cmd |
0x06 | RCTime | cmd | |
0x0A | EasyMonitor | fetched | cmd |
0x10 | UBAErrorMessage1 | cmd | |
0x11 | UBAErrorMessage2 | cmd | |
0x12 | RCErrorMessage | cmd | |
0x13 | RCErrorMessage2 | cmd | |
0x14 | UBATotalUptime | fetched | cmd |
0x15 | UBAMaintenanceData | cmd | |
0x16 | UBAParameters | fetched | cmd |
0x18 | UBAMonitorFast | cmd | |
0x19 | UBAMonitorSlow | cmd | |
0x1A | UBASetPoints | cmd | |
0x1C | UBAMaintenanceStatus | cmd | |
0x1E | WM10TempMessage | cmd | |
0x23 | JunkersSetMixer | fetched | cmd |
0x26 | UBASettingsWW | fetched | cmd |
0x28 | WeatherComp | fetched | cmd |
0x2A | MC110Status | cmd | |
0x2E | Meters | cmd | |
0x33 | UBAParameterWW | fetched | cmd |
0x34 | UBAMonitorWW | cmd | |
0x35 | UBAFlags | cmd | |
0x37 | WWSettings | fetched | cmd |
0x38 | WWTimer | fetched | cmd |
0x39 | WWCircTimer | fetched | cmd |
0x3A | RC30WWSettings | fetched | cmd |
0x3B | Energy | cmd | |
0x3D | RC35Set | cmd | |
0x3E | RC35Monitor | cmd | |
0x3F | RC35Timer | cmd | |
0x40 | RC30Temp | cmd | |
0x41 | RC30Monitor | cmd | |
0x42 | RC35Timer2 | cmd | |
0x47 | RC35Set | cmd | |
0x48 | RC35Monitor | cmd | |
0x49 | RC35Timer | cmd | |
0x4C | RC35Timer2 | cmd | |
0x51 | RC35Set | cmd | |
0x52 | RC35Monitor | cmd | |
0x53 | RC35Timer | cmd | |
0x56 | RC35Timer2 | cmd | |
0x5B | RC35Set | cmd | |
0x5C | RC35Monitor | cmd | |
0x5D | RC35Timer | cmd | |
0x60 | RC35Timer2 | cmd | |
0x96 | SM10Config | fetched | cmd |
0x97 | SM10Monitor | cmd | |
0x9C | WM10MonitorMessage | cmd | |
0x9D | WM10SetMessage | cmd | |
0xA2 | RCError | cmd | |
0xA3 | RCOutdoorTemp | cmd | |
0xA5 | IBASettings | fetched | cmd |
0xA7 | RC30Set | cmd | |
0xAA | MMConfigMessage | fetched | cmd |
0xAB | MMStatusMessage | cmd | |
0xAC | MMSetMessage | cmd | |
0xAF | RC20Remote | cmd | |
0xB0 | RC10Set | cmd | |
0xB1 | RC10Monitor | cmd | |
0xBB | HybridSettings | fetched | cmd |
0xBF | ErrorMessage | cmd | |
0xC2 | UBAErrorMessage3 | cmd | |
0xD1 | UBAOutdoorTemp | cmd | |
0xE3 | UBAMonitorSlowPlus2 | cmd | |
0xE4 | UBAMonitorFastPlus | cmd | |
0xE5 | UBAMonitorSlowPlus | cmd | |
0xE6 | UBAParametersPlus | fetched | cmd |
0xE9 | UBAMonitorWWPlus | cmd | |
0xEA | UBAParameterWWPlus | fetched | cmd |
0x0101 | ISM1Set | fetched | cmd |
0x0103 | ISM1StatusMessage | fetched | cmd |
0x0104 | ISM2StatusMessage | cmd | |
0x010C | IPMStatusMessage | cmd | |
0x011E | IPMTempMessage | cmd | |
0x0165 | JunkersSet | cmd | |
0x0166 | JunkersSet | cmd | |
0x0167 | JunkersSet | cmd | |
0x0168 | JunkersSet | cmd | |
0x016F | JunkersMonitor | cmd | |
0x0170 | JunkersMonitor | cmd | |
0x0171 | JunkersMonitor | cmd | |
0x0172 | JunkersMonitor | cmd | |
0x0179 | JunkersSet | cmd | |
0x017A | JunkersSet | cmd | |
0x017B | JunkersSet | cmd | |
0x017C | JunkersSet | cmd | |
0x01D3 | JunkersDhw | fetched | cmd |
0x023A | RC300OutdoorTemp | fetched | cmd |
0x023E | PVSettings | fetched | cmd |
0x0240 | RC300Settings | fetched | cmd |
0x0267 | RC300Floordry | cmd | |
0x0291 | HPMode | fetched | cmd |
0x0292 | HPMode | fetched | cmd |
0x0293 | HPMode | fetched | cmd |
0x0294 | HPMode | fetched | cmd |
0x029B | RC300Curves | cmd | |
0x029C | RC300Curves | cmd | |
0x029D | RC300Curves | cmd | |
0x029E | RC300Curves | cmd | |
0x029F | RC300Curves | cmd | |
0x02A0 | RC300Curves | cmd | |
0x02A1 | RC300Curves | cmd | |
0x02A2 | RC300Curves | cmd | |
0x02A5 | RC300Monitor | cmd | |
0x02A6 | RC300Monitor | cmd | |
0x02A7 | CRFMonitor | cmd | |
0x02A8 | RC300Monitor | cmd | |
0x02A9 | RC300Monitor | cmd | |
0x02AA | RC300Monitor | cmd | |
0x02AB | RC300Monitor | cmd | |
0x02AC | RC300Monitor | cmd | |
0x02AF | RC300Summer | cmd | |
0x02B0 | RC300Summer | cmd | |
0x02B1 | RC300Summer | cmd | |
0x02B2 | RC300Summer | cmd | |
0x02B3 | RC300Summer | cmd | |
0x02B4 | RC300Summer | cmd | |
0x02B5 | RC300Summer | cmd | |
0x02B6 | RC300Summer | cmd | |
0x02B9 | RC300Set | cmd | |
0x02BA | RC300Set | cmd | |
0x02BB | RC300Set | cmd | |
0x02BC | RC300Set | cmd | |
0x02BD | RC300Set | cmd | |
0x02BE | RC300Set | cmd | |
0x02BF | RC300Set | cmd | |
0x02C0 | RC300Set | cmd | |
0x02CC | HPPressure | fetched | cmd |
0x02CD | MMPLUSSetMessage_HC | fetched | cmd |
0x02CE | RC300Set2 | cmd | |
0x02D0 | RC300Set2 | cmd | |
0x02D2 | RC300Set2 | cmd | |
0x02D5 | MMPLUSSetMessage_HC | fetched | cmd |
0x02D7 | MMPLUSStatusMessage_HC | cmd | |
0x02DF | MMPLUSStatusMessage_HC | cmd | |
0x02F5 | RC300WWmode | fetched | cmd |
0x02F6 | RC300WW2mode | fetched | cmd |
0x031B | RC300WWtemp | fetched | cmd |
0x031D | RC300WWmode2 | cmd | |
0x031E | RC300WWmode2 | cmd | |
0x0358 | SM100SystemConfig | fetched | cmd |
0x035A | SM100CircuitConfig | fetched | cmd |
0x035C | SM100HeatAssist | fetched | cmd |
0x035D | SM100Circuit2Config | fetched | cmd |
0x035F | SM100Config1 | fetched | cmd |
0x0361 | SM100Differential | fetched | cmd |
0x0362 | SM100Monitor | cmd | |
0x0363 | SM100Monitor2 | cmd | |
0x0364 | SM100Status | cmd | |
0x0366 | SM100Config | cmd | |
0x036A | SM100Status2 | cmd | |
0x0380 | SM100CollectorConfig | fetched | cmd |
0x038E | SM100Energy | fetched | cmd |
0x0391 | SM100Time | fetched | cmd |
0x0467 | HPSet | cmd | |
0x0468 | HPSet | cmd | |
0x0469 | HPSet | cmd | |
0x046A | HPSet | cmd | |
0x0471 | RC300Summer2 | cmd | |
0x0472 | RC300Summer2 | cmd | |
0x0473 | RC300Summer2 | cmd | |
0x0474 | RC300Summer2 | cmd | |
0x0475 | RC300Summer2 | cmd | |
0x0476 | RC300Summer2 | cmd | |
0x0477 | RC300Summer2 | cmd | |
0x0478 | RC300Summer2 | cmd | |
0x047B | HP2 | cmd | |
0x0484 | HPSilentMode | fetched | cmd |
0x0485 | HpCooling | fetched | cmd |
0x0486 | HpInConfig | fetched | cmd |
0x0488 | HPValve | fetched | cmd |
0x048A | HpPool | fetched | cmd |
0x048B | HPPumps | fetched | cmd |
0x048D | HpPower | fetched | cmd |
0x048F | HpTemperatures | cmd | |
0x0491 | HPAdditionalHeater | fetched | cmd |
0x0492 | HpHeaterConfig | fetched | cmd |
0x0494 | UBAEnergySupplied | cmd | |
0x0495 | UBAInformation | cmd | |
0x0499 | HPDhwSettings | fetched | cmd |
0x049C | HPSettings2 | fetched | cmd |
0x049D | HPSettings3 | fetched | cmd |
0x04A2 | HpInput | fetched | cmd |
0x04A5 | HPFan | fetched | cmd |
0x04AE | HPEnergy | fetched | cmd |
0x04AF | HPMeters | fetched | cmd |
0x056B | VentilationMode | fetched | cmd |
0x0583 | VentilationMonitor | cmd | |
0x0585 | Blowerspeed | cmd | |
0x0587 | Bypass | cmd | |
0x05BA | HpPoolStatus | fetched | cmd |
0x05D9 | Airquality | cmd | |
0x0772 | HIUSettings | cmd | |
0x0779 | HIUMonitor | cmd | |
0x0935 | EM100SetMessage | fetched | cmd |
0x0936 | EM100OutMessage | cmd | |
0x0937 | EM100TempMessage | cmd | |
0x0938 | EM100InputMessage | cmd | |
0x0939 | EM100MonitorMessage | cmd | |
0x093A | EM100ConfigMessage | cmd | |
0x0998 | HPSettings | fetched | cmd |
0x0999 | HPFunctionTest | fetched | cmd |
0x099B | HPFlowTemp | cmd | |
0x099C | HPComp | cmd | |
0x09A0 | HPTemperature | cmd |
All devices and entities~
device name | device type | product id | shortname | fullname | type [options...] | (min/max) | uom | writeable | discovery entityid v3.4 | discovery entityid |
---|---|---|---|---|---|---|---|---|---|
CS6800i/WLW176i | boiler | 8 | reset | reset | cmd [-|maintenance|error|history|message] | True | sensor.boiler_reset | sensor.boiler_reset | |
CS6800i/WLW176i | boiler | 8 | heatingoff | force heating off | boolean | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
CS6800i/WLW176i | boiler | 8 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
CS6800i/WLW176i | boiler | 8 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
CS6800i/WLW176i | boiler | 8 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
CS6800i/WLW176i | boiler | 8 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
CS6800i/WLW176i | boiler | 8 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
CS6800i/WLW176i | boiler | 8 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
CS6800i/WLW176i | boiler | 8 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
CS6800i/WLW176i | boiler | 8 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
CS6800i/WLW176i | boiler | 8 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
CS6800i/WLW176i | boiler | 8 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
CS6800i/WLW176i | boiler | 8 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
CS6800i/WLW176i | boiler | 8 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
CS6800i/WLW176i | boiler | 8 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
CS6800i/WLW176i | boiler | 8 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
CS6800i/WLW176i | boiler | 8 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
CS6800i/WLW176i | boiler | 8 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
CS6800i/WLW176i | boiler | 8 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
CS6800i/WLW176i | boiler | 8 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
CS6800i/WLW176i | boiler | 8 | setflowtemp | set flow temperature | uint8 (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
CS6800i/WLW176i | boiler | 8 | setburnpow | burner set power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
CS6800i/WLW176i | boiler | 8 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
CS6800i/WLW176i | boiler | 8 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
CS6800i/WLW176i | boiler | 8 | burnstarts | burner starts | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
CS6800i/WLW176i | boiler | 8 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
CS6800i/WLW176i | boiler | 8 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
CS6800i/WLW176i | boiler | 8 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
CS6800i/WLW176i | boiler | 8 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
CS6800i/WLW176i | boiler | 8 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
CS6800i/WLW176i | boiler | 8 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
CS6800i/WLW176i | boiler | 8 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
CS6800i/WLW176i | boiler | 8 | servicecodenumber | service code number | uint16 (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
CS6800i/WLW176i | boiler | 8 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
CS6800i/WLW176i | boiler | 8 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
CS6800i/WLW176i | boiler | 8 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
CS6800i/WLW176i | boiler | 8 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
CS6800i/WLW176i | boiler | 8 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
CS6800i/WLW176i | boiler | 8 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
CS6800i/WLW176i | boiler | 8 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
CS6800i/WLW176i | boiler | 8 | nrgdhw | energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_dhw_energy | sensor.boiler_dhw_nrgdhw |
CS6800i/WLW176i | boiler | 8 | nrgheat | energy heating | uint24 (>=0<=167772) | kWh | False | sensor.boiler_energy_heating | sensor.boiler_nrgheat |
CS6800i/WLW176i | boiler | 8 | metertotal | meter total | uint24 (>=0<=167772) | kWh | False | sensor.boiler_meter_total | sensor.boiler_metertotal |
CS6800i/WLW176i | boiler | 8 | metercomp | meter compressor | uint24 (>=0<=167772) | kWh | False | sensor.boiler_meter_compressor | sensor.boiler_metercomp |
CS6800i/WLW176i | boiler | 8 | metereheat | meter e-heater | uint24 (>=0<=167772) | kWh | False | sensor.boiler_meter_e-heater | sensor.boiler_metereheat |
CS6800i/WLW176i | boiler | 8 | meterheat | meter heating | uint24 (>=0<=167772) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat |
CS6800i/WLW176i | boiler | 8 | meterdhw | meter | uint24 (>=0<=167772) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meterdhw |
CS6800i/WLW176i | boiler | 8 | uptimetotal | heatpump total uptime | time (>=0<=279620) | minutes | False | sensor.boiler_heatpump_total_uptime | sensor.boiler_uptimetotal |
CS6800i/WLW176i | boiler | 8 | uptimecontrol | total operating time heat | time (>=0<=279620) | minutes | False | sensor.boiler_total_operating_time_heat | sensor.boiler_uptimecontrol |
CS6800i/WLW176i | boiler | 8 | uptimecompheating | operating time compressor heating | time (>=0<=279620) | minutes | False | sensor.boiler_operating_time_compressor_heating | sensor.boiler_uptimecompheating |
CS6800i/WLW176i | boiler | 8 | uptimecompcooling | operating time compressor cooling | time (>=0<=279620) | minutes | False | sensor.boiler_operating_time_compressor_cooling | sensor.boiler_uptimecompcooling |
CS6800i/WLW176i | boiler | 8 | uptimecompdhw | operating time compressor | time (>=0<=279620) | minutes | False | sensor.boiler_dhw_operating_time_compressor | sensor.boiler_dhw_uptimecompdhw |
CS6800i/WLW176i | boiler | 8 | uptimecomppool | operating time compressor pool | time (>=0<=279620) | minutes | False | sensor.boiler_operating_time_compressor_pool | sensor.boiler_uptimecomppool |
CS6800i/WLW176i | boiler | 8 | totalcompstarts | total compressor control starts | uint24 (>=0<=16777213) | False | sensor.boiler_total_compressor_control_starts | sensor.boiler_totalcompstarts | |
CS6800i/WLW176i | boiler | 8 | heatingstarts | heating control starts | uint24 (>=0<=16777213) | False | sensor.boiler_heating_control_starts | sensor.boiler_heatingstarts | |
CS6800i/WLW176i | boiler | 8 | coolingstarts | cooling control starts | uint24 (>=0<=16777213) | False | sensor.boiler_cooling_control_starts | sensor.boiler_coolingstarts | |
CS6800i/WLW176i | boiler | 8 | starts2 | control starts2 | uint24 (>=0<=16777213) | False | sensor.boiler_dhw_control_starts2 | sensor.boiler_dhw_starts2 | |
CS6800i/WLW176i | boiler | 8 | poolstarts | pool control starts | uint24 (>=0<=16777213) | False | sensor.boiler_pool_control_starts | sensor.boiler_poolstarts | |
CS6800i/WLW176i | boiler | 8 | nrgconstotal | total energy consumption | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_total_energy_consumption | sensor.boiler_nrgconstotal |
CS6800i/WLW176i | boiler | 8 | nrgconscomptotal | total energy consumption compressor | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_total_energy_consumption_compressor | sensor.boiler_nrgconscomptotal |
CS6800i/WLW176i | boiler | 8 | nrgconscompheating | energy consumption compressor heating | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_energy_consumption_compressor_heating | sensor.boiler_nrgconscompheating |
CS6800i/WLW176i | boiler | 8 | nrgconscompdhw | energy consumption compressor | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_dhw_energy_consumption_compressor | sensor.boiler_dhw_nrgconscompdhw |
CS6800i/WLW176i | boiler | 8 | nrgconscompcooling | energy consumption compressor cooling | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_energy_consumption_compressor_cooling | sensor.boiler_nrgconscompcooling |
CS6800i/WLW176i | boiler | 8 | nrgconscomppool | energy consumption compressor pool | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_energy_consumption_compressor_pool | sensor.boiler_nrgconscomppool |
CS6800i/WLW176i | boiler | 8 | auxelecheatnrgconstotal | total aux elec. heater energy consumption | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_total_aux_elec._heater_energy_consumption | sensor.boiler_auxelecheatnrgconstotal |
CS6800i/WLW176i | boiler | 8 | auxelecheatnrgconsheating | aux elec. heater energy consumption heating | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_aux_elec._heater_energy_consumption_heating | sensor.boiler_auxelecheatnrgconsheating |
CS6800i/WLW176i | boiler | 8 | auxelecheatnrgconsdhw | aux elec. heater energy consumption | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_dhw_aux_elec._heater_energy_consumption | sensor.boiler_dhw_auxelecheatnrgconsdhw |
CS6800i/WLW176i | boiler | 8 | auxelecheatnrgconspool | aux elec. heater energy consumption pool | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_aux_elec._heater_energy_consumption_pool | sensor.boiler_auxelecheatnrgconspool |
CS6800i/WLW176i | boiler | 8 | nrgsupptotal | total energy supplied | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_total_energy_supplied | sensor.boiler_nrgsupptotal |
CS6800i/WLW176i | boiler | 8 | nrgsuppheating | total energy supplied heating | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_total_energy_supplied_heating | sensor.boiler_nrgsuppheating |
CS6800i/WLW176i | boiler | 8 | nrgsuppdhw | total energy warm supplied | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_dhw_total_energy_warm_supplied | sensor.boiler_dhw_nrgsuppdhw |
CS6800i/WLW176i | boiler | 8 | nrgsuppcooling | total energy supplied cooling | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_total_energy_supplied_cooling | sensor.boiler_nrgsuppcooling |
CS6800i/WLW176i | boiler | 8 | nrgsupppool | total energy supplied pool | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_total_energy_supplied_pool | sensor.boiler_nrgsupppool |
CS6800i/WLW176i | boiler | 8 | hppower | compressor power output | uint8 (>=0<=25) | kW | False | sensor.boiler_compressor_power_output | sensor.boiler_hppower |
CS6800i/WLW176i | boiler | 8 | hpmaxpower | compressor max power | uint8 (>=0<=100) | % | True | number.boiler_compressor_max_power | number.boiler_hpmaxpower |
CS6800i/WLW176i | boiler | 8 | hpsetdiffpress | set differental pressure | uint8 (>=150<=750) | mbar | True | number.boiler_set_differental_pressure | number.boiler_hpsetdiffpress |
CS6800i/WLW176i | boiler | 8 | hpcompon | hp compressor | boolean | False | binary_sensor.boiler_hp_compressor | binary_sensor.boiler_hpcompon | |
CS6800i/WLW176i | boiler | 8 | hpactivity | compressor activity | enum [none|heating|cooling|hot water|pool|unknown|defrost] | False | sensor.boiler_compressor_activity | sensor.boiler_hpactivity | |
CS6800i/WLW176i | boiler | 8 | hpbrinepumpspd | brine pump speed | uint8 (>=0<=100) | % | False | sensor.boiler_brine_pump_speed | sensor.boiler_hpbrinepumpspd |
CS6800i/WLW176i | boiler | 8 | hpswitchvalve | switch valve | boolean | False | binary_sensor.boiler_switch_valve | binary_sensor.boiler_hpswitchvalve | |
CS6800i/WLW176i | boiler | 8 | hpcompspd | compressor speed | uint8 (>=0<=100) | % | False | sensor.boiler_compressor_speed | sensor.boiler_hpcompspd |
CS6800i/WLW176i | boiler | 8 | hpcircspd | circulation pump speed | uint8 (>=0<=100) | % | False | sensor.boiler_circulation_pump_speed | sensor.boiler_hpcircspd |
CS6800i/WLW176i | boiler | 8 | hpbrinein | brine in/evaporator | int16 (>=-3199<=3199) | C | False | sensor.boiler_brine_in/evaporator | sensor.boiler_hpbrinein |
CS6800i/WLW176i | boiler | 8 | hpbrineout | brine out/condenser | int16 (>=-3199<=3199) | C | False | sensor.boiler_brine_out/condenser | sensor.boiler_hpbrineout |
CS6800i/WLW176i | boiler | 8 | hptc0 | heat carrier return (TC0) | int16 (>=-3199<=3199) | C | False | sensor.boiler_heat_carrier_return_(TC0) | sensor.boiler_hptc0 |
CS6800i/WLW176i | boiler | 8 | hptc1 | heat carrier forward (TC1) | int16 (>=-3199<=3199) | C | False | sensor.boiler_heat_carrier_forward_(TC1) | sensor.boiler_hptc1 |
CS6800i/WLW176i | boiler | 8 | hptc3 | condenser temperature (TC3) | int16 (>=-3199<=3199) | C | False | sensor.boiler_condenser_temperature_(TC3) | sensor.boiler_hptc3 |
CS6800i/WLW176i | boiler | 8 | hptr1 | compressor temperature (TR1) | int16 (>=-3199<=3199) | C | False | sensor.boiler_compressor_temperature_(TR1) | sensor.boiler_hptr1 |
CS6800i/WLW176i | boiler | 8 | hptr3 | refrigerant temperature liquid side (condenser output) (TR3) | int16 (>=-3199<=3199) | C | False | sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3) | sensor.boiler_hptr3 |
CS6800i/WLW176i | boiler | 8 | hptr4 | evaporator inlet temperature (TR4) | int16 (>=-3199<=3199) | C | False | sensor.boiler_evaporator_inlet_temperature_(TR4) | sensor.boiler_hptr4 |
CS6800i/WLW176i | boiler | 8 | hptr5 | compressor inlet temperature (TR5) | int16 (>=-3199<=3199) | C | False | sensor.boiler_compressor_inlet_temperature_(TR5) | sensor.boiler_hptr5 |
CS6800i/WLW176i | boiler | 8 | hptr6 | compressor outlet temperature (TR6) | int16 (>=-3199<=3199) | C | False | sensor.boiler_compressor_outlet_temperature_(TR6) | sensor.boiler_hptr6 |
CS6800i/WLW176i | boiler | 8 | hptr7 | refrigerant temperature gas side (condenser input) (TR7) | int16 (>=-3199<=3199) | C | False | sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7) | sensor.boiler_hptr7 |
CS6800i/WLW176i | boiler | 8 | hptl2 | air inlet temperature (TL2) | int16 (>=-3199<=3199) | C | False | sensor.boiler_air_inlet_temperature_(TL2) | sensor.boiler_hptl2 |
CS6800i/WLW176i | boiler | 8 | hppl1 | low pressure side temperature (PL1) | int16 (>=-3199<=3199) | C | False | sensor.boiler_low_pressure_side_temperature_(PL1) | sensor.boiler_hppl1 |
CS6800i/WLW176i | boiler | 8 | hpph1 | high pressure side temperature (PH1) | int16 (>=-3199<=3199) | C | False | sensor.boiler_high_pressure_side_temperature_(PH1) | sensor.boiler_hpph1 |
CS6800i/WLW176i | boiler | 8 | hpta4 | drain pan temp (TA4) | int16 (>=-3199<=3199) | C | False | sensor.boiler_drain_pan_temp_(TA4) | sensor.boiler_hpta4 |
CS6800i/WLW176i | boiler | 8 | hptw1 | reservoir temp (TW1) | int16 (>=-3199<=3199) | C | False | sensor.boiler_reservoir_temp_(TW1) | sensor.boiler_hptw1 |
CS6800i/WLW176i | boiler | 8 | poolsettemp | pool set temperature | uint8 (>=0<=127) | C | True | number.boiler_pool_set_temperature | number.boiler_poolsettemp |
CS6800i/WLW176i | boiler | 8 | hp4way | 4-way valve (VR4) | enum [cooling & defrost|heating & dhw] | False | sensor.boiler_4-way_valve_(VR4) | sensor.boiler_hp4way | |
CS6800i/WLW176i | boiler | 8 | hpin1opt | input 1 options | string | True | sensor.boiler_input_1_options | sensor.boiler_hpin1opt | |
CS6800i/WLW176i | boiler | 8 | hpin2opt | input 2 options | string | True | sensor.boiler_input_2_options | sensor.boiler_hpin2opt | |
CS6800i/WLW176i | boiler | 8 | hpin3opt | input 3 options | string | True | sensor.boiler_input_3_options | sensor.boiler_hpin3opt | |
CS6800i/WLW176i | boiler | 8 | hpin4opt | input 4 options | string | True | sensor.boiler_input_4_options | sensor.boiler_hpin4opt | |
CS6800i/WLW176i | boiler | 8 | maxheatcomp | heat limit compressor | enum [0 kW|2 kW|3 kW|4 kW|6 kW|9 kW] | True | select.boiler_heat_limit_compressor | select.boiler_maxheatcomp | |
CS6800i/WLW176i | boiler | 8 | maxheatheat | heat limit heating | enum [0 kW|2 kW|3 kW|4 kW|6 kW|9 kW] | True | select.boiler_heat_limit_heating | select.boiler_maxheatheat | |
CS6800i/WLW176i | boiler | 8 | maxheatdhw | heat limit | enum [0 kW|2 kW|3 kW|4 kW|6 kW|9 kW] | True | select.boiler_dhw_heat_limit | select.boiler_dhw_maxheatdhw | |
CS6800i/WLW176i | boiler | 8 | mandefrost | manual defrost | boolean | True | switch.boiler_manual_defrost | switch.boiler_mandefrost | |
CS6800i/WLW176i | boiler | 8 | pvcooling | cooling only with PV | boolean | True | switch.boiler_cooling_only_with_PV | switch.boiler_pvcooling | |
CS6800i/WLW176i | boiler | 8 | auxheateronly | aux heater only | boolean | True | switch.boiler_aux_heater_only | switch.boiler_auxheateronly | |
CS6800i/WLW176i | boiler | 8 | auxheateroff | disable aux heater | boolean | True | switch.boiler_disable_aux_heater | switch.boiler_auxheateroff | |
CS6800i/WLW176i | boiler | 8 | auxheaterstatus | aux heater status | uint8 (>=0<=100) | % | False | sensor.boiler_aux_heater_status | sensor.boiler_auxheaterstatus |
CS6800i/WLW176i | boiler | 8 | auxheaterdelay | aux heater on delay | uint16 (>=10<=1000) | K*min | True | number.boiler_aux_heater_on_delay | number.boiler_auxheaterdelay |
CS6800i/WLW176i | boiler | 8 | auxmaxlimit | aux heater max limit | uint8 (>=0<=10) | K | True | number.boiler_aux_heater_max_limit | number.boiler_auxmaxlimit |
CS6800i/WLW176i | boiler | 8 | auxlimitstart | aux heater limit start | uint8 (>=0<=10) | K | True | number.boiler_aux_heater_limit_start | number.boiler_auxlimitstart |
CS6800i/WLW176i | boiler | 8 | auxheatrmode | aux heater mode | enum [eco|comfort] | True | select.boiler_aux_heater_mode | select.boiler_auxheatrmode | |
CS6800i/WLW176i | boiler | 8 | hphystheat | on/off hyst heat | uint16 (>=50<=1500) | K*min | True | number.boiler_on/off_hyst_heat | number.boiler_hphystheat |
CS6800i/WLW176i | boiler | 8 | hphystcool | on/off hyst cool | uint16 (>=50<=1500) | K*min | True | number.boiler_on/off_hyst_cool | number.boiler_hphystcool |
CS6800i/WLW176i | boiler | 8 | hphystpool | on/off hyst pool | uint16 (>=50<=1500) | K*min | True | number.boiler_on/off_hyst_pool | number.boiler_hphystpool |
CS6800i/WLW176i | boiler | 8 | silentmode | silent mode | enum [off|auto|on] | True | select.boiler_silent_mode | select.boiler_silentmode | |
CS6800i/WLW176i | boiler | 8 | silentfrom | silent mode from | uint8 (>=0<=3810) | minutes | True | number.boiler_silent_mode_from | number.boiler_silentfrom |
CS6800i/WLW176i | boiler | 8 | silentto | silent mode to | uint8 (>=0<=3810) | minutes | True | number.boiler_silent_mode_to | number.boiler_silentto |
CS6800i/WLW176i | boiler | 8 | mintempsilent | min outside temp for silent mode | int8 (>=-126<=126) | C | True | number.boiler_min_outside_temp_for_silent_mode | number.boiler_mintempsilent |
CS6800i/WLW176i | boiler | 8 | tempparmode | outside temp parallel mode | int8 (>=-126<=126) | C | True | number.boiler_outside_temp_parallel_mode | number.boiler_tempparmode |
CS6800i/WLW176i | boiler | 8 | auxheatmix | aux heater mixing valve | int8 (>=-100<=100) | % | False | sensor.boiler_aux_heater_mixing_valve | sensor.boiler_auxheatmix |
CS6800i/WLW176i | boiler | 8 | tempdiffheat | temp diff TC3/TC0 heat | uint8 (>=2<=10) | K | True | number.boiler_temp_diff_TC3/TC0_heat | number.boiler_tempdiffheat |
CS6800i/WLW176i | boiler | 8 | tempdiffcool | temp diff TC3/TC0 cool | uint8 (>=2<=10) | K | True | number.boiler_temp_diff_TC3/TC0_cool | number.boiler_tempdiffcool |
CS6800i/WLW176i | boiler | 8 | vpcooling | valve/pump cooling | boolean | True | switch.boiler_valve/pump_cooling | switch.boiler_vpcooling | |
CS6800i/WLW176i | boiler | 8 | heatcable | heating cable | boolean | True | switch.boiler_heating_cable | switch.boiler_heatcable | |
CS6800i/WLW176i | boiler | 8 | vc0valve | VC0 valve | boolean | True | switch.boiler_VC0_valve | switch.boiler_vc0valve | |
CS6800i/WLW176i | boiler | 8 | primepump | primary heatpump | boolean | True | switch.boiler_primary_heatpump | switch.boiler_primepump | |
CS6800i/WLW176i | boiler | 8 | primepumpmod | primary heatpump modulation | uint8 (>=0<=100) | % | True | number.boiler_primary_heatpump_modulation | number.boiler_primepumpmod |
CS6800i/WLW176i | boiler | 8 | hp3way | 3-way valve | boolean | True | switch.boiler_3-way_valve | switch.boiler_hp3way | |
CS6800i/WLW176i | boiler | 8 | elheatstep1 | el. heater step 1 | boolean | True | switch.boiler_el._heater_step_1 | switch.boiler_elheatstep1 | |
CS6800i/WLW176i | boiler | 8 | elheatstep2 | el. heater step 2 | boolean | True | switch.boiler_el._heater_step_2 | switch.boiler_elheatstep2 | |
CS6800i/WLW176i | boiler | 8 | elheatstep3 | el. heater step 3 | boolean | True | switch.boiler_el._heater_step_3 | switch.boiler_elheatstep3 | |
CS6800i/WLW176i | boiler | 8 | hpea0 | condensate reservoir heating (EA0) | boolean | False | binary_sensor.boiler_condensate_reservoir_heating_(EA0) | binary_sensor.boiler_hpea0 | |
CS6800i/WLW176i | boiler | 8 | hppumpmode | primary heatpump mode | enum [auto|continuous] | True | select.boiler_primary_heatpump_mode | select.boiler_hppumpmode | |
CS6800i/WLW176i | boiler | 8 | fan | fan | uint8 (>=20<=100) | % | True | number.boiler_fan | number.boiler_fan |
CS6800i/WLW176i | boiler | 8 | shutdown | shutdown | boolean | True | switch.boiler_shutdown | switch.boiler_shutdown | |
CS6800i/WLW176i | boiler | 8 | alternatingop | alternating operation | boolean | True | switch.boiler_dhw_alternating_operation | switch.boiler_dhw_alternatingop | |
CS6800i/WLW176i | boiler | 8 | altopprioheat | prioritise heating during dhw | uint8 (>=20<=120) | minutes | True | number.boiler_dhw_prioritise_heating_during_dhw | number.boiler_dhw_altopprioheat |
CS6800i/WLW176i | boiler | 8 | altoppriodhw | prioritise dhw during heating | uint8 (>=30<=120) | minutes | True | number.boiler_dhw_prioritise_dhw_during_heating | number.boiler_dhw_altoppriodhw |
CS6800i/WLW176i | boiler | 8 | comfoff | comfort switch off | uint8 (>=15<=65) | C | True | number.boiler_dhw_comfort_switch_off | number.boiler_dhw_comfoff |
CS6800i/WLW176i | boiler | 8 | ecooff | eco switch off | uint8 (>=15<=65) | C | True | number.boiler_dhw_eco_switch_off | number.boiler_dhw_ecooff |
CS6800i/WLW176i | boiler | 8 | ecoplusoff | eco+ switch off | uint8 (>=48<=63) | C | True | number.boiler_dhw_eco+_switch_off | number.boiler_dhw_ecoplusoff |
CS6800i/WLW176i | boiler | 8 | comfdiff | comfort diff | uint8 (>=6<=12) | K | True | number.boiler_dhw_comfort_diff | number.boiler_dhw_comfdiff |
CS6800i/WLW176i | boiler | 8 | ecodiff | eco diff | uint8 (>=6<=12) | K | True | number.boiler_dhw_eco_diff | number.boiler_dhw_ecodiff |
CS6800i/WLW176i | boiler | 8 | ecoplusdiff | eco+ diff | uint8 (>=6<=12) | K | True | number.boiler_dhw_eco+_diff | number.boiler_dhw_ecoplusdiff |
CS6800i/WLW176i | boiler | 8 | comfstop | comfort stop temp | uint8 (>=0<=254) | C | True | number.boiler_dhw_comfort_stop_temp | number.boiler_dhw_comfstop |
CS6800i/WLW176i | boiler | 8 | ecostop | eco stop temp | uint8 (>=0<=254) | C | True | number.boiler_dhw_eco_stop_temp | number.boiler_dhw_ecostop |
CS6800i/WLW176i | boiler | 8 | ecoplusstop | eco+ stop temp | uint8 (>=0<=254) | C | True | number.boiler_dhw_eco+_stop_temp | number.boiler_dhw_ecoplusstop |
CS6800i/WLW176i | boiler | 8 | hpcircpumpdhw | circulation pump available during dhw | boolean | True | switch.boiler_dhw_circulation_pump_available_during_dhw | switch.boiler_dhw_hpcircpumpdhw | |
CS6800i/WLW176i | boiler | 8 | tapactivated | turn on/off | boolean | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | |
CS6800i/WLW176i | boiler | 8 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp |
CS6800i/WLW176i | boiler | 8 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp |
CS6800i/WLW176i | boiler | 8 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow |
CS6800i/WLW176i | boiler | 8 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus |
CS6800i/WLW176i | boiler | 8 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff |
CS6800i/WLW176i | boiler | 8 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle |
CS6800i/WLW176i | boiler | 8 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp |
CS6800i/WLW176i | boiler | 8 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | |
CS6800i/WLW176i | boiler | 8 | comfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | |
CS6800i/WLW176i | boiler | 8 | comfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | |
CS6800i/WLW176i | boiler | 8 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset |
CS6800i/WLW176i | boiler | 8 | chargeoptimization | charge optimization | boolean | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | |
CS6800i/WLW176i | boiler | 8 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower |
CS6800i/WLW176i | boiler | 8 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp |
CS6800i/WLW176i | boiler | 8 | circpump | circulation pump available | boolean | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | |
CS6800i/WLW176i | boiler | 8 | chargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | |
CS6800i/WLW176i | boiler | 8 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston |
CS6800i/WLW176i | boiler | 8 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff |
CS6800i/WLW176i | boiler | 8 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp |
CS6800i/WLW176i | boiler | 8 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | |
CS6800i/WLW176i | boiler | 8 | circ | circulation active | boolean | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | |
CS6800i/WLW176i | boiler | 8 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp |
CS6800i/WLW176i | boiler | 8 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 |
CS6800i/WLW176i | boiler | 8 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow |
CS6800i/WLW176i | boiler | 8 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 |
CS6800i/WLW176i | boiler | 8 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 |
CS6800i/WLW176i | boiler | 8 | activated | activated | boolean | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | |
CS6800i/WLW176i | boiler | 8 | onetime | one time charging | boolean | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | |
CS6800i/WLW176i | boiler | 8 | disinfecting | disinfecting | boolean | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | |
CS6800i/WLW176i | boiler | 8 | charging | charging | boolean | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | |
CS6800i/WLW176i | boiler | 8 | recharging | recharging | boolean | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | |
CS6800i/WLW176i | boiler | 8 | tempok | temperature ok | boolean | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | |
CS6800i/WLW176i | boiler | 8 | active | active | boolean | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | |
CS6800i/WLW176i | boiler | 8 | 3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | |
CS6800i/WLW176i | boiler | 8 | setpumppower | set pump power | uint8 (>=0<=100) | % | False | sensor.boiler_dhw_set_pump_power | sensor.boiler_dhw_setpumppower |
CS6800i/WLW176i | boiler | 8 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp |
CS6800i/WLW176i | boiler | 8 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp |
CS6800i/WLW176i | boiler | 8 | starts | starts | uint24 (>=0<=16777213) | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | |
CS6800i/WLW176i | boiler | 8 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm |
C1200W | boiler | 12 | reset | reset | cmd [-|maintenance|error|history|message] | True | sensor.boiler_reset | sensor.boiler_reset | |
C1200W | boiler | 12 | heatingoff | force heating off | boolean | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
C1200W | boiler | 12 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
C1200W | boiler | 12 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
C1200W | boiler | 12 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
C1200W | boiler | 12 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
C1200W | boiler | 12 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
C1200W | boiler | 12 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
C1200W | boiler | 12 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
C1200W | boiler | 12 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
C1200W | boiler | 12 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
C1200W | boiler | 12 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
C1200W | boiler | 12 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
C1200W | boiler | 12 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
C1200W | boiler | 12 | burngas | gas | boolean | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
C1200W | boiler | 12 | burngas2 | gas stage 2 | boolean | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
C1200W | boiler | 12 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr |
C1200W | boiler | 12 | fanwork | fan | boolean | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
C1200W | boiler | 12 | ignwork | ignition | boolean | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
C1200W | boiler | 12 | oilpreheat | oil preheating | boolean | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
C1200W | boiler | 12 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower |
C1200W | boiler | 12 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower |
C1200W | boiler | 12 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod |
C1200W | boiler | 12 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
C1200W | boiler | 12 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock |
C1200W | boiler | 12 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
C1200W | boiler | 12 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
C1200W | boiler | 12 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
C1200W | boiler | 12 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
C1200W | boiler | 12 | curveon | heatingcurve on | boolean | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | |
C1200W | boiler | 12 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase |
C1200W | boiler | 12 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend |
C1200W | boiler | 12 | summertemp | summer temperature | uint8 (>=0<=30) | C | True | number.boiler_summer_temperature | number.boiler_summertemp |
C1200W | boiler | 12 | nofrostmode | nofrost mode | boolean | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | |
C1200W | boiler | 12 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp |
C1200W | boiler | 12 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
C1200W | boiler | 12 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
C1200W | boiler | 12 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
C1200W | boiler | 12 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
C1200W | boiler | 12 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
C1200W | boiler | 12 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
C1200W | boiler | 12 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
C1200W | boiler | 12 | setflowtemp | set flow temperature | uint8 (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
C1200W | boiler | 12 | setburnpow | burner set power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
C1200W | boiler | 12 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
C1200W | boiler | 12 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
C1200W | boiler | 12 | burnstarts | burner starts | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
C1200W | boiler | 12 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
C1200W | boiler | 12 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
C1200W | boiler | 12 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
C1200W | boiler | 12 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
C1200W | boiler | 12 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
C1200W | boiler | 12 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
C1200W | boiler | 12 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
C1200W | boiler | 12 | servicecodenumber | service code number | uint16 (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
C1200W | boiler | 12 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
C1200W | boiler | 12 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
C1200W | boiler | 12 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
C1200W | boiler | 12 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
C1200W | boiler | 12 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
C1200W | boiler | 12 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
C1200W | boiler | 12 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat |
C1200W | boiler | 12 | meterdhw | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meterdhw |
C1200W | boiler | 12 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat |
C1200W | boiler | 12 | gasmeterdhw | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeterdhw |
C1200W | boiler | 12 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 |
C1200W | boiler | 12 | nrgdhw2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrgdhw2 |
C1200W | boiler | 12 | tapactivated | turn on/off | boolean | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | |
C1200W | boiler | 12 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp |
C1200W | boiler | 12 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp |
C1200W | boiler | 12 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow |
C1200W | boiler | 12 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus |
C1200W | boiler | 12 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff |
C1200W | boiler | 12 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle |
C1200W | boiler | 12 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp |
C1200W | boiler | 12 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | |
C1200W | boiler | 12 | comfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | |
C1200W | boiler | 12 | comfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | |
C1200W | boiler | 12 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset |
C1200W | boiler | 12 | chargeoptimization | charge optimization | boolean | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | |
C1200W | boiler | 12 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower |
C1200W | boiler | 12 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp |
C1200W | boiler | 12 | circpump | circulation pump available | boolean | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | |
C1200W | boiler | 12 | chargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | |
C1200W | boiler | 12 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston |
C1200W | boiler | 12 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff |
C1200W | boiler | 12 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp |
C1200W | boiler | 12 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | |
C1200W | boiler | 12 | circ | circulation active | boolean | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | |
C1200W | boiler | 12 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp |
C1200W | boiler | 12 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 |
C1200W | boiler | 12 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow |
C1200W | boiler | 12 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 |
C1200W | boiler | 12 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 |
C1200W | boiler | 12 | activated | activated | boolean | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | |
C1200W | boiler | 12 | onetime | one time charging | boolean | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | |
C1200W | boiler | 12 | disinfecting | disinfecting | boolean | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | |
C1200W | boiler | 12 | charging | charging | boolean | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | |
C1200W | boiler | 12 | recharging | recharging | boolean | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | |
C1200W | boiler | 12 | tempok | temperature ok | boolean | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | |
C1200W | boiler | 12 | active | active | boolean | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | |
C1200W | boiler | 12 | 3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | |
C1200W | boiler | 12 | setpumppower | set pump power | uint8 (>=0<=100) | % | False | sensor.boiler_dhw_set_pump_power | sensor.boiler_dhw_setpumppower |
C1200W | boiler | 12 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp |
C1200W | boiler | 12 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp |
C1200W | boiler | 12 | starts | starts | uint24 (>=0<=16777213) | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | |
C1200W | boiler | 12 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm |
C1200W | boiler | 12 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower |
C1200W | boiler | 12 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
C1200W | boiler | 12 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat |
C1200W | boiler | 12 | nrgdhw | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrgdhw |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | reset | reset | cmd [-|maintenance|error|history|message] | True | sensor.boiler_reset | sensor.boiler_reset | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | heatingoff | force heating off | boolean | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | burngas | gas | boolean | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | burngas2 | gas stage 2 | boolean | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | fanwork | fan | boolean | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | ignwork | ignition | boolean | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | oilpreheat | oil preheating | boolean | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | curveon | heatingcurve on | boolean | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | summertemp | summer temperature | uint8 (>=0<=30) | C | True | number.boiler_summer_temperature | number.boiler_summertemp |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | nofrostmode | nofrost mode | boolean | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | setflowtemp | set flow temperature | uint8 (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | setburnpow | burner set power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | burnstarts | burner starts | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | servicecodenumber | service code number | uint16 (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | meterdhw | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meterdhw |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | gasmeterdhw | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeterdhw |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | nrgdhw2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrgdhw2 |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | tapactivated | turn on/off | boolean | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | comfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | comfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | chargeoptimization | charge optimization | boolean | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | circpump | circulation pump available | boolean | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | chargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | circ | circulation active | boolean | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | activated | activated | boolean | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | onetime | one time charging | boolean | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | disinfecting | disinfecting | boolean | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | charging | charging | boolean | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | recharging | recharging | boolean | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | tempok | temperature ok | boolean | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | active | active | boolean | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | 3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | setpumppower | set pump power | uint8 (>=0<=100) | % | False | sensor.boiler_dhw_set_pump_power | sensor.boiler_dhw_setpumppower |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | starts | starts | uint24 (>=0<=16777213) | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | nrgdhw | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrgdhw |
GB125/GB135/MC10 | boiler | 72 | reset | reset | cmd [-|maintenance|error|history|message] | True | sensor.boiler_reset | sensor.boiler_reset | |
GB125/GB135/MC10 | boiler | 72 | heatingoff | force heating off | boolean | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
GB125/GB135/MC10 | boiler | 72 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
GB125/GB135/MC10 | boiler | 72 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
GB125/GB135/MC10 | boiler | 72 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
GB125/GB135/MC10 | boiler | 72 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
GB125/GB135/MC10 | boiler | 72 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
GB125/GB135/MC10 | boiler | 72 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
GB125/GB135/MC10 | boiler | 72 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
GB125/GB135/MC10 | boiler | 72 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
GB125/GB135/MC10 | boiler | 72 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
GB125/GB135/MC10 | boiler | 72 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
GB125/GB135/MC10 | boiler | 72 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
GB125/GB135/MC10 | boiler | 72 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
GB125/GB135/MC10 | boiler | 72 | burngas | gas | boolean | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
GB125/GB135/MC10 | boiler | 72 | burngas2 | gas stage 2 | boolean | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
GB125/GB135/MC10 | boiler | 72 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr |
GB125/GB135/MC10 | boiler | 72 | fanwork | fan | boolean | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
GB125/GB135/MC10 | boiler | 72 | ignwork | ignition | boolean | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
GB125/GB135/MC10 | boiler | 72 | oilpreheat | oil preheating | boolean | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
GB125/GB135/MC10 | boiler | 72 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower |
GB125/GB135/MC10 | boiler | 72 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower |
GB125/GB135/MC10 | boiler | 72 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod |
GB125/GB135/MC10 | boiler | 72 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
GB125/GB135/MC10 | boiler | 72 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock |
GB125/GB135/MC10 | boiler | 72 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
GB125/GB135/MC10 | boiler | 72 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
GB125/GB135/MC10 | boiler | 72 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
GB125/GB135/MC10 | boiler | 72 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
GB125/GB135/MC10 | boiler | 72 | curveon | heatingcurve on | boolean | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | |
GB125/GB135/MC10 | boiler | 72 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase |
GB125/GB135/MC10 | boiler | 72 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend |
GB125/GB135/MC10 | boiler | 72 | summertemp | summer temperature | uint8 (>=0<=30) | C | True | number.boiler_summer_temperature | number.boiler_summertemp |
GB125/GB135/MC10 | boiler | 72 | nofrostmode | nofrost mode | boolean | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | |
GB125/GB135/MC10 | boiler | 72 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp |
GB125/GB135/MC10 | boiler | 72 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
GB125/GB135/MC10 | boiler | 72 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
GB125/GB135/MC10 | boiler | 72 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
GB125/GB135/MC10 | boiler | 72 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
GB125/GB135/MC10 | boiler | 72 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
GB125/GB135/MC10 | boiler | 72 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
GB125/GB135/MC10 | boiler | 72 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
GB125/GB135/MC10 | boiler | 72 | setflowtemp | set flow temperature | uint8 (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
GB125/GB135/MC10 | boiler | 72 | setburnpow | burner set power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
GB125/GB135/MC10 | boiler | 72 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
GB125/GB135/MC10 | boiler | 72 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
GB125/GB135/MC10 | boiler | 72 | burnstarts | burner starts | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
GB125/GB135/MC10 | boiler | 72 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
GB125/GB135/MC10 | boiler | 72 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
GB125/GB135/MC10 | boiler | 72 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
GB125/GB135/MC10 | boiler | 72 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
GB125/GB135/MC10 | boiler | 72 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
GB125/GB135/MC10 | boiler | 72 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
GB125/GB135/MC10 | boiler | 72 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
GB125/GB135/MC10 | boiler | 72 | servicecodenumber | service code number | uint16 (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
GB125/GB135/MC10 | boiler | 72 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
GB125/GB135/MC10 | boiler | 72 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
GB125/GB135/MC10 | boiler | 72 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
GB125/GB135/MC10 | boiler | 72 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
GB125/GB135/MC10 | boiler | 72 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
GB125/GB135/MC10 | boiler | 72 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
GB125/GB135/MC10 | boiler | 72 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat |
GB125/GB135/MC10 | boiler | 72 | meterdhw | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meterdhw |
GB125/GB135/MC10 | boiler | 72 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat |
GB125/GB135/MC10 | boiler | 72 | gasmeterdhw | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeterdhw |
GB125/GB135/MC10 | boiler | 72 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 |
GB125/GB135/MC10 | boiler | 72 | nrgdhw2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrgdhw2 |
GB125/GB135/MC10 | boiler | 72 | tapactivated | turn on/off | boolean | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | |
GB125/GB135/MC10 | boiler | 72 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp |
GB125/GB135/MC10 | boiler | 72 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp |
GB125/GB135/MC10 | boiler | 72 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow |
GB125/GB135/MC10 | boiler | 72 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus |
GB125/GB135/MC10 | boiler | 72 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff |
GB125/GB135/MC10 | boiler | 72 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle |
GB125/GB135/MC10 | boiler | 72 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp |
GB125/GB135/MC10 | boiler | 72 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | |
GB125/GB135/MC10 | boiler | 72 | comfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | |
GB125/GB135/MC10 | boiler | 72 | comfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | |
GB125/GB135/MC10 | boiler | 72 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset |
GB125/GB135/MC10 | boiler | 72 | chargeoptimization | charge optimization | boolean | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | |
GB125/GB135/MC10 | boiler | 72 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower |
GB125/GB135/MC10 | boiler | 72 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp |
GB125/GB135/MC10 | boiler | 72 | circpump | circulation pump available | boolean | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | |
GB125/GB135/MC10 | boiler | 72 | chargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | |
GB125/GB135/MC10 | boiler | 72 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston |
GB125/GB135/MC10 | boiler | 72 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff |
GB125/GB135/MC10 | boiler | 72 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp |
GB125/GB135/MC10 | boiler | 72 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | |
GB125/GB135/MC10 | boiler | 72 | circ | circulation active | boolean | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | |
GB125/GB135/MC10 | boiler | 72 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp |
GB125/GB135/MC10 | boiler | 72 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 |
GB125/GB135/MC10 | boiler | 72 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow |
GB125/GB135/MC10 | boiler | 72 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 |
GB125/GB135/MC10 | boiler | 72 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 |
GB125/GB135/MC10 | boiler | 72 | activated | activated | boolean | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | |
GB125/GB135/MC10 | boiler | 72 | onetime | one time charging | boolean | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | |
GB125/GB135/MC10 | boiler | 72 | disinfecting | disinfecting | boolean | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | |
GB125/GB135/MC10 | boiler | 72 | charging | charging | boolean | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | |
GB125/GB135/MC10 | boiler | 72 | recharging | recharging | boolean | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | |
GB125/GB135/MC10 | boiler | 72 | tempok | temperature ok | boolean | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | |
GB125/GB135/MC10 | boiler | 72 | active | active | boolean | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | |
GB125/GB135/MC10 | boiler | 72 | 3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | |
GB125/GB135/MC10 | boiler | 72 | setpumppower | set pump power | uint8 (>=0<=100) | % | False | sensor.boiler_dhw_set_pump_power | sensor.boiler_dhw_setpumppower |
GB125/GB135/MC10 | boiler | 72 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp |
GB125/GB135/MC10 | boiler | 72 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp |
GB125/GB135/MC10 | boiler | 72 | starts | starts | uint24 (>=0<=16777213) | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | |
GB125/GB135/MC10 | boiler | 72 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm |
GB125/GB135/MC10 | boiler | 72 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower |
GB125/GB135/MC10 | boiler | 72 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
GB125/GB135/MC10 | boiler | 72 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat |
GB125/GB135/MC10 | boiler | 72 | nrgdhw | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrgdhw |
Cascade CM10 | boiler | 81 | reset | reset | cmd [-|maintenance|error|history|message] | True | sensor.boiler_reset | sensor.boiler_reset | |
Cascade CM10 | boiler | 81 | heatingoff | force heating off | boolean | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
Cascade CM10 | boiler | 81 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
Cascade CM10 | boiler | 81 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
Cascade CM10 | boiler | 81 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
Cascade CM10 | boiler | 81 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
Cascade CM10 | boiler | 81 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
Cascade CM10 | boiler | 81 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
Cascade CM10 | boiler | 81 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
Cascade CM10 | boiler | 81 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
Cascade CM10 | boiler | 81 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
Cascade CM10 | boiler | 81 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
Cascade CM10 | boiler | 81 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
Cascade CM10 | boiler | 81 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
Cascade CM10 | boiler | 81 | burngas | gas | boolean | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
Cascade CM10 | boiler | 81 | burngas2 | gas stage 2 | boolean | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
Cascade CM10 | boiler | 81 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr |
Cascade CM10 | boiler | 81 | fanwork | fan | boolean | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
Cascade CM10 | boiler | 81 | ignwork | ignition | boolean | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
Cascade CM10 | boiler | 81 | oilpreheat | oil preheating | boolean | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
Cascade CM10 | boiler | 81 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower |
Cascade CM10 | boiler | 81 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower |
Cascade CM10 | boiler | 81 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod |
Cascade CM10 | boiler | 81 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
Cascade CM10 | boiler | 81 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock |
Cascade CM10 | boiler | 81 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
Cascade CM10 | boiler | 81 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
Cascade CM10 | boiler | 81 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
Cascade CM10 | boiler | 81 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
Cascade CM10 | boiler | 81 | curveon | heatingcurve on | boolean | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | |
Cascade CM10 | boiler | 81 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase |
Cascade CM10 | boiler | 81 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend |
Cascade CM10 | boiler | 81 | summertemp | summer temperature | uint8 (>=0<=30) | C | True | number.boiler_summer_temperature | number.boiler_summertemp |
Cascade CM10 | boiler | 81 | nofrostmode | nofrost mode | boolean | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | |
Cascade CM10 | boiler | 81 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp |
Cascade CM10 | boiler | 81 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
Cascade CM10 | boiler | 81 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
Cascade CM10 | boiler | 81 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
Cascade CM10 | boiler | 81 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
Cascade CM10 | boiler | 81 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
Cascade CM10 | boiler | 81 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
Cascade CM10 | boiler | 81 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
Cascade CM10 | boiler | 81 | setflowtemp | set flow temperature | uint8 (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
Cascade CM10 | boiler | 81 | setburnpow | burner set power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
Cascade CM10 | boiler | 81 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
Cascade CM10 | boiler | 81 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
Cascade CM10 | boiler | 81 | burnstarts | burner starts | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
Cascade CM10 | boiler | 81 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
Cascade CM10 | boiler | 81 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
Cascade CM10 | boiler | 81 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
Cascade CM10 | boiler | 81 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
Cascade CM10 | boiler | 81 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
Cascade CM10 | boiler | 81 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
Cascade CM10 | boiler | 81 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
Cascade CM10 | boiler | 81 | servicecodenumber | service code number | uint16 (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
Cascade CM10 | boiler | 81 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
Cascade CM10 | boiler | 81 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
Cascade CM10 | boiler | 81 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
Cascade CM10 | boiler | 81 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
Cascade CM10 | boiler | 81 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
Cascade CM10 | boiler | 81 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
Cascade CM10 | boiler | 81 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat |
Cascade CM10 | boiler | 81 | meterdhw | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meterdhw |
Cascade CM10 | boiler | 81 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat |
Cascade CM10 | boiler | 81 | gasmeterdhw | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeterdhw |
Cascade CM10 | boiler | 81 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 |
Cascade CM10 | boiler | 81 | nrgdhw2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrgdhw2 |
Cascade CM10 | boiler | 81 | tapactivated | turn on/off | boolean | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | |
Cascade CM10 | boiler | 81 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp |
Cascade CM10 | boiler | 81 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp |
Cascade CM10 | boiler | 81 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow |
Cascade CM10 | boiler | 81 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus |
Cascade CM10 | boiler | 81 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff |
Cascade CM10 | boiler | 81 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle |
Cascade CM10 | boiler | 81 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp |
Cascade CM10 | boiler | 81 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | |
Cascade CM10 | boiler | 81 | comfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | |
Cascade CM10 | boiler | 81 | comfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | |
Cascade CM10 | boiler | 81 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset |
Cascade CM10 | boiler | 81 | chargeoptimization | charge optimization | boolean | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | |
Cascade CM10 | boiler | 81 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower |
Cascade CM10 | boiler | 81 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp |
Cascade CM10 | boiler | 81 | circpump | circulation pump available | boolean | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | |
Cascade CM10 | boiler | 81 | chargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | |
Cascade CM10 | boiler | 81 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston |
Cascade CM10 | boiler | 81 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff |
Cascade CM10 | boiler | 81 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp |
Cascade CM10 | boiler | 81 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | |
Cascade CM10 | boiler | 81 | circ | circulation active | boolean | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | |
Cascade CM10 | boiler | 81 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp |
Cascade CM10 | boiler | 81 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 |
Cascade CM10 | boiler | 81 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow |
Cascade CM10 | boiler | 81 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 |
Cascade CM10 | boiler | 81 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 |
Cascade CM10 | boiler | 81 | activated | activated | boolean | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | |
Cascade CM10 | boiler | 81 | onetime | one time charging | boolean | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | |
Cascade CM10 | boiler | 81 | disinfecting | disinfecting | boolean | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | |
Cascade CM10 | boiler | 81 | charging | charging | boolean | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | |
Cascade CM10 | boiler | 81 | recharging | recharging | boolean | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | |
Cascade CM10 | boiler | 81 | tempok | temperature ok | boolean | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | |
Cascade CM10 | boiler | 81 | active | active | boolean | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | |
Cascade CM10 | boiler | 81 | 3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | |
Cascade CM10 | boiler | 81 | setpumppower | set pump power | uint8 (>=0<=100) | % | False | sensor.boiler_dhw_set_pump_power | sensor.boiler_dhw_setpumppower |
Cascade CM10 | boiler | 81 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp |
Cascade CM10 | boiler | 81 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp |
Cascade CM10 | boiler | 81 | starts | starts | uint24 (>=0<=16777213) | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | |
Cascade CM10 | boiler | 81 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm |
Cascade CM10 | boiler | 81 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower |
Cascade CM10 | boiler | 81 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
Cascade CM10 | boiler | 81 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat |
Cascade CM10 | boiler | 81 | nrgdhw | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrgdhw |
Logamax Plus GB022 | boiler | 84 | reset | reset | cmd [-|maintenance|error|history|message] | True | sensor.boiler_reset | sensor.boiler_reset | |
Logamax Plus GB022 | boiler | 84 | heatingoff | force heating off | boolean | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
Logamax Plus GB022 | boiler | 84 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
Logamax Plus GB022 | boiler | 84 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
Logamax Plus GB022 | boiler | 84 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
Logamax Plus GB022 | boiler | 84 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
Logamax Plus GB022 | boiler | 84 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
Logamax Plus GB022 | boiler | 84 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
Logamax Plus GB022 | boiler | 84 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
Logamax Plus GB022 | boiler | 84 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
Logamax Plus GB022 | boiler | 84 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
Logamax Plus GB022 | boiler | 84 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
Logamax Plus GB022 | boiler | 84 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
Logamax Plus GB022 | boiler | 84 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
Logamax Plus GB022 | boiler | 84 | burngas | gas | boolean | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
Logamax Plus GB022 | boiler | 84 | burngas2 | gas stage 2 | boolean | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
Logamax Plus GB022 | boiler | 84 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr |
Logamax Plus GB022 | boiler | 84 | fanwork | fan | boolean | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
Logamax Plus GB022 | boiler | 84 | ignwork | ignition | boolean | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
Logamax Plus GB022 | boiler | 84 | oilpreheat | oil preheating | boolean | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
Logamax Plus GB022 | boiler | 84 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower |
Logamax Plus GB022 | boiler | 84 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower |
Logamax Plus GB022 | boiler | 84 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod |
Logamax Plus GB022 | boiler | 84 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
Logamax Plus GB022 | boiler | 84 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock |
Logamax Plus GB022 | boiler | 84 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
Logamax Plus GB022 | boiler | 84 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
Logamax Plus GB022 | boiler | 84 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
Logamax Plus GB022 | boiler | 84 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
Logamax Plus GB022 | boiler | 84 | curveon | heatingcurve on | boolean | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | |
Logamax Plus GB022 | boiler | 84 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase |
Logamax Plus GB022 | boiler | 84 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend |
Logamax Plus GB022 | boiler | 84 | summertemp | summer temperature | uint8 (>=0<=30) | C | True | number.boiler_summer_temperature | number.boiler_summertemp |
Logamax Plus GB022 | boiler | 84 | nofrostmode | nofrost mode | boolean | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | |
Logamax Plus GB022 | boiler | 84 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp |
Logamax Plus GB022 | boiler | 84 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
Logamax Plus GB022 | boiler | 84 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
Logamax Plus GB022 | boiler | 84 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
Logamax Plus GB022 | boiler | 84 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
Logamax Plus GB022 | boiler | 84 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
Logamax Plus GB022 | boiler | 84 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
Logamax Plus GB022 | boiler | 84 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
Logamax Plus GB022 | boiler | 84 | setflowtemp | set flow temperature | uint8 (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
Logamax Plus GB022 | boiler | 84 | setburnpow | burner set power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
Logamax Plus GB022 | boiler | 84 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
Logamax Plus GB022 | boiler | 84 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
Logamax Plus GB022 | boiler | 84 | burnstarts | burner starts | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
Logamax Plus GB022 | boiler | 84 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
Logamax Plus GB022 | boiler | 84 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
Logamax Plus GB022 | boiler | 84 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
Logamax Plus GB022 | boiler | 84 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
Logamax Plus GB022 | boiler | 84 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
Logamax Plus GB022 | boiler | 84 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
Logamax Plus GB022 | boiler | 84 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
Logamax Plus GB022 | boiler | 84 | servicecodenumber | service code number | uint16 (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
Logamax Plus GB022 | boiler | 84 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
Logamax Plus GB022 | boiler | 84 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
Logamax Plus GB022 | boiler | 84 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
Logamax Plus GB022 | boiler | 84 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
Logamax Plus GB022 | boiler | 84 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
Logamax Plus GB022 | boiler | 84 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
Logamax Plus GB022 | boiler | 84 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat |
Logamax Plus GB022 | boiler | 84 | meterdhw | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meterdhw |
Logamax Plus GB022 | boiler | 84 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat |
Logamax Plus GB022 | boiler | 84 | gasmeterdhw | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeterdhw |
Logamax Plus GB022 | boiler | 84 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 |
Logamax Plus GB022 | boiler | 84 | nrgdhw2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrgdhw2 |
Logamax Plus GB022 | boiler | 84 | tapactivated | turn on/off | boolean | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | |
Logamax Plus GB022 | boiler | 84 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp |
Logamax Plus GB022 | boiler | 84 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp |
Logamax Plus GB022 | boiler | 84 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow |
Logamax Plus GB022 | boiler | 84 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus |
Logamax Plus GB022 | boiler | 84 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff |
Logamax Plus GB022 | boiler | 84 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle |
Logamax Plus GB022 | boiler | 84 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp |
Logamax Plus GB022 | boiler | 84 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | |
Logamax Plus GB022 | boiler | 84 | comfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | |
Logamax Plus GB022 | boiler | 84 | comfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | |
Logamax Plus GB022 | boiler | 84 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset |
Logamax Plus GB022 | boiler | 84 | chargeoptimization | charge optimization | boolean | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | |
Logamax Plus GB022 | boiler | 84 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower |
Logamax Plus GB022 | boiler | 84 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp |
Logamax Plus GB022 | boiler | 84 | circpump | circulation pump available | boolean | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | |
Logamax Plus GB022 | boiler | 84 | chargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | |
Logamax Plus GB022 | boiler | 84 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston |
Logamax Plus GB022 | boiler | 84 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff |
Logamax Plus GB022 | boiler | 84 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp |
Logamax Plus GB022 | boiler | 84 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | |
Logamax Plus GB022 | boiler | 84 | circ | circulation active | boolean | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | |
Logamax Plus GB022 | boiler | 84 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp |
Logamax Plus GB022 | boiler | 84 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 |
Logamax Plus GB022 | boiler | 84 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow |
Logamax Plus GB022 | boiler | 84 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 |
Logamax Plus GB022 | boiler | 84 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 |
Logamax Plus GB022 | boiler | 84 | activated | activated | boolean | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | |
Logamax Plus GB022 | boiler | 84 | onetime | one time charging | boolean | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | |
Logamax Plus GB022 | boiler | 84 | disinfecting | disinfecting | boolean | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | |
Logamax Plus GB022 | boiler | 84 | charging | charging | boolean | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | |
Logamax Plus GB022 | boiler | 84 | recharging | recharging | boolean | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | |
Logamax Plus GB022 | boiler | 84 | tempok | temperature ok | boolean | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | |
Logamax Plus GB022 | boiler | 84 | active | active | boolean | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | |
Logamax Plus GB022 | boiler | 84 | 3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | |
Logamax Plus GB022 | boiler | 84 | setpumppower | set pump power | uint8 (>=0<=100) | % | False | sensor.boiler_dhw_set_pump_power | sensor.boiler_dhw_setpumppower |
Logamax Plus GB022 | boiler | 84 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp |
Logamax Plus GB022 | boiler | 84 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp |
Logamax Plus GB022 | boiler | 84 | starts | starts | uint24 (>=0<=16777213) | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | |
Logamax Plus GB022 | boiler | 84 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm |
Logamax Plus GB022 | boiler | 84 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower |
Logamax Plus GB022 | boiler | 84 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
Logamax Plus GB022 | boiler | 84 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat |
Logamax Plus GB022 | boiler | 84 | nrgdhw | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrgdhw |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | reset | reset | cmd [-|maintenance|error|history|message] | True | sensor.boiler_reset | sensor.boiler_reset | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | heatingoff | force heating off | boolean | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | burngas | gas | boolean | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | burngas2 | gas stage 2 | boolean | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | fanwork | fan | boolean | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | ignwork | ignition | boolean | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | oilpreheat | oil preheating | boolean | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | curveon | heatingcurve on | boolean | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | summertemp | summer temperature | uint8 (>=0<=30) | C | True | number.boiler_summer_temperature | number.boiler_summertemp |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | nofrostmode | nofrost mode | boolean | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | setflowtemp | set flow temperature | uint8 (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | setburnpow | burner set power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | burnstarts | burner starts | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | servicecodenumber | service code number | uint16 (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | meterdhw | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meterdhw |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | gasmeterdhw | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeterdhw |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | nrgdhw2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrgdhw2 |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | tapactivated | turn on/off | boolean | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | comfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | comfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | chargeoptimization | charge optimization | boolean | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | circpump | circulation pump available | boolean | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | chargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | circ | circulation active | boolean | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | activated | activated | boolean | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | onetime | one time charging | boolean | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | disinfecting | disinfecting | boolean | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | charging | charging | boolean | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | recharging | recharging | boolean | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | tempok | temperature ok | boolean | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | active | active | boolean | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | 3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | setpumppower | set pump power | uint8 (>=0<=100) | % | False | sensor.boiler_dhw_set_pump_power | sensor.boiler_dhw_setpumppower |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | starts | starts | uint24 (>=0<=16777213) | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | nrgdhw | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrgdhw |
Topline/GB162 | boiler | 115 | reset | reset | cmd [-|maintenance|error|history|message] | True | sensor.boiler_reset | sensor.boiler_reset | |
Topline/GB162 | boiler | 115 | heatingoff | force heating off | boolean | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
Topline/GB162 | boiler | 115 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
Topline/GB162 | boiler | 115 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
Topline/GB162 | boiler | 115 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
Topline/GB162 | boiler | 115 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
Topline/GB162 | boiler | 115 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
Topline/GB162 | boiler | 115 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
Topline/GB162 | boiler | 115 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
Topline/GB162 | boiler | 115 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
Topline/GB162 | boiler | 115 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
Topline/GB162 | boiler | 115 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
Topline/GB162 | boiler | 115 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
Topline/GB162 | boiler | 115 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
Topline/GB162 | boiler | 115 | burngas | gas | boolean | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
Topline/GB162 | boiler | 115 | burngas2 | gas stage 2 | boolean | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
Topline/GB162 | boiler | 115 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr |
Topline/GB162 | boiler | 115 | fanwork | fan | boolean | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
Topline/GB162 | boiler | 115 | ignwork | ignition | boolean | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
Topline/GB162 | boiler | 115 | oilpreheat | oil preheating | boolean | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
Topline/GB162 | boiler | 115 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower |
Topline/GB162 | boiler | 115 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower |
Topline/GB162 | boiler | 115 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod |
Topline/GB162 | boiler | 115 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
Topline/GB162 | boiler | 115 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock |
Topline/GB162 | boiler | 115 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
Topline/GB162 | boiler | 115 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
Topline/GB162 | boiler | 115 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
Topline/GB162 | boiler | 115 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
Topline/GB162 | boiler | 115 | curveon | heatingcurve on | boolean | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | |
Topline/GB162 | boiler | 115 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase |
Topline/GB162 | boiler | 115 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend |
Topline/GB162 | boiler | 115 | summertemp | summer temperature | uint8 (>=0<=30) | C | True | number.boiler_summer_temperature | number.boiler_summertemp |
Topline/GB162 | boiler | 115 | nofrostmode | nofrost mode | boolean | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | |
Topline/GB162 | boiler | 115 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp |
Topline/GB162 | boiler | 115 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
Topline/GB162 | boiler | 115 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
Topline/GB162 | boiler | 115 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
Topline/GB162 | boiler | 115 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
Topline/GB162 | boiler | 115 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
Topline/GB162 | boiler | 115 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
Topline/GB162 | boiler | 115 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
Topline/GB162 | boiler | 115 | setflowtemp | set flow temperature | uint8 (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
Topline/GB162 | boiler | 115 | setburnpow | burner set power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
Topline/GB162 | boiler | 115 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
Topline/GB162 | boiler | 115 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
Topline/GB162 | boiler | 115 | burnstarts | burner starts | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
Topline/GB162 | boiler | 115 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
Topline/GB162 | boiler | 115 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
Topline/GB162 | boiler | 115 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
Topline/GB162 | boiler | 115 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
Topline/GB162 | boiler | 115 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
Topline/GB162 | boiler | 115 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
Topline/GB162 | boiler | 115 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
Topline/GB162 | boiler | 115 | servicecodenumber | service code number | uint16 (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
Topline/GB162 | boiler | 115 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
Topline/GB162 | boiler | 115 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
Topline/GB162 | boiler | 115 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
Topline/GB162 | boiler | 115 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
Topline/GB162 | boiler | 115 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
Topline/GB162 | boiler | 115 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
Topline/GB162 | boiler | 115 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat |
Topline/GB162 | boiler | 115 | meterdhw | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meterdhw |
Topline/GB162 | boiler | 115 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat |
Topline/GB162 | boiler | 115 | gasmeterdhw | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeterdhw |
Topline/GB162 | boiler | 115 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 |
Topline/GB162 | boiler | 115 | nrgdhw2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrgdhw2 |
Topline/GB162 | boiler | 115 | tapactivated | turn on/off | boolean | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | |
Topline/GB162 | boiler | 115 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp |
Topline/GB162 | boiler | 115 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp |
Topline/GB162 | boiler | 115 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow |
Topline/GB162 | boiler | 115 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus |
Topline/GB162 | boiler | 115 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff |
Topline/GB162 | boiler | 115 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle |
Topline/GB162 | boiler | 115 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp |
Topline/GB162 | boiler | 115 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | |
Topline/GB162 | boiler | 115 | comfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | |
Topline/GB162 | boiler | 115 | comfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | |
Topline/GB162 | boiler | 115 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset |
Topline/GB162 | boiler | 115 | chargeoptimization | charge optimization | boolean | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | |
Topline/GB162 | boiler | 115 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower |
Topline/GB162 | boiler | 115 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp |
Topline/GB162 | boiler | 115 | circpump | circulation pump available | boolean | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | |
Topline/GB162 | boiler | 115 | chargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | |
Topline/GB162 | boiler | 115 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston |
Topline/GB162 | boiler | 115 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff |
Topline/GB162 | boiler | 115 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp |
Topline/GB162 | boiler | 115 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | |
Topline/GB162 | boiler | 115 | circ | circulation active | boolean | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | |
Topline/GB162 | boiler | 115 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp |
Topline/GB162 | boiler | 115 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 |
Topline/GB162 | boiler | 115 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow |
Topline/GB162 | boiler | 115 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 |
Topline/GB162 | boiler | 115 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 |
Topline/GB162 | boiler | 115 | activated | activated | boolean | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | |
Topline/GB162 | boiler | 115 | onetime | one time charging | boolean | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | |
Topline/GB162 | boiler | 115 | disinfecting | disinfecting | boolean | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | |
Topline/GB162 | boiler | 115 | charging | charging | boolean | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | |
Topline/GB162 | boiler | 115 | recharging | recharging | boolean | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | |
Topline/GB162 | boiler | 115 | tempok | temperature ok | boolean | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | |
Topline/GB162 | boiler | 115 | active | active | boolean | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | |
Topline/GB162 | boiler | 115 | 3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | |
Topline/GB162 | boiler | 115 | setpumppower | set pump power | uint8 (>=0<=100) | % | False | sensor.boiler_dhw_set_pump_power | sensor.boiler_dhw_setpumppower |
Topline/GB162 | boiler | 115 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp |
Topline/GB162 | boiler | 115 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp |
Topline/GB162 | boiler | 115 | starts | starts | uint24 (>=0<=16777213) | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | |
Topline/GB162 | boiler | 115 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm |
Topline/GB162 | boiler | 115 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower |
Topline/GB162 | boiler | 115 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
Topline/GB162 | boiler | 115 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat |
Topline/GB162 | boiler | 115 | nrgdhw | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrgdhw |
Cascade MCM10 | boiler | 121 | reset | reset | cmd [-|maintenance|error|history|message] | True | sensor.boiler_reset | sensor.boiler_reset | |
Cascade MCM10 | boiler | 121 | heatingoff | force heating off | boolean | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
Cascade MCM10 | boiler | 121 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
Cascade MCM10 | boiler | 121 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
Cascade MCM10 | boiler | 121 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
Cascade MCM10 | boiler | 121 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
Cascade MCM10 | boiler | 121 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
Cascade MCM10 | boiler | 121 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
Cascade MCM10 | boiler | 121 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
Cascade MCM10 | boiler | 121 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
Cascade MCM10 | boiler | 121 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
Cascade MCM10 | boiler | 121 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
Cascade MCM10 | boiler | 121 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
Cascade MCM10 | boiler | 121 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
Cascade MCM10 | boiler | 121 | burngas | gas | boolean | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
Cascade MCM10 | boiler | 121 | burngas2 | gas stage 2 | boolean | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
Cascade MCM10 | boiler | 121 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr |
Cascade MCM10 | boiler | 121 | fanwork | fan | boolean | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
Cascade MCM10 | boiler | 121 | ignwork | ignition | boolean | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
Cascade MCM10 | boiler | 121 | oilpreheat | oil preheating | boolean | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
Cascade MCM10 | boiler | 121 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower |
Cascade MCM10 | boiler | 121 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower |
Cascade MCM10 | boiler | 121 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod |
Cascade MCM10 | boiler | 121 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
Cascade MCM10 | boiler | 121 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock |
Cascade MCM10 | boiler | 121 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
Cascade MCM10 | boiler | 121 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
Cascade MCM10 | boiler | 121 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
Cascade MCM10 | boiler | 121 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
Cascade MCM10 | boiler | 121 | curveon | heatingcurve on | boolean | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | |
Cascade MCM10 | boiler | 121 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase |
Cascade MCM10 | boiler | 121 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend |
Cascade MCM10 | boiler | 121 | summertemp | summer temperature | uint8 (>=0<=30) | C | True | number.boiler_summer_temperature | number.boiler_summertemp |
Cascade MCM10 | boiler | 121 | nofrostmode | nofrost mode | boolean | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | |
Cascade MCM10 | boiler | 121 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp |
Cascade MCM10 | boiler | 121 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
Cascade MCM10 | boiler | 121 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
Cascade MCM10 | boiler | 121 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
Cascade MCM10 | boiler | 121 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
Cascade MCM10 | boiler | 121 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
Cascade MCM10 | boiler | 121 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
Cascade MCM10 | boiler | 121 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
Cascade MCM10 | boiler | 121 | setflowtemp | set flow temperature | uint8 (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
Cascade MCM10 | boiler | 121 | setburnpow | burner set power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
Cascade MCM10 | boiler | 121 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
Cascade MCM10 | boiler | 121 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
Cascade MCM10 | boiler | 121 | burnstarts | burner starts | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
Cascade MCM10 | boiler | 121 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
Cascade MCM10 | boiler | 121 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
Cascade MCM10 | boiler | 121 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
Cascade MCM10 | boiler | 121 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
Cascade MCM10 | boiler | 121 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
Cascade MCM10 | boiler | 121 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
Cascade MCM10 | boiler | 121 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
Cascade MCM10 | boiler | 121 | servicecodenumber | service code number | uint16 (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
Cascade MCM10 | boiler | 121 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
Cascade MCM10 | boiler | 121 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
Cascade MCM10 | boiler | 121 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
Cascade MCM10 | boiler | 121 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
Cascade MCM10 | boiler | 121 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
Cascade MCM10 | boiler | 121 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
Cascade MCM10 | boiler | 121 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat |
Cascade MCM10 | boiler | 121 | meterdhw | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meterdhw |
Cascade MCM10 | boiler | 121 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat |
Cascade MCM10 | boiler | 121 | gasmeterdhw | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeterdhw |
Cascade MCM10 | boiler | 121 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 |
Cascade MCM10 | boiler | 121 | nrgdhw2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrgdhw2 |
Cascade MCM10 | boiler | 121 | tapactivated | turn on/off | boolean | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | |
Cascade MCM10 | boiler | 121 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp |
Cascade MCM10 | boiler | 121 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp |
Cascade MCM10 | boiler | 121 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow |
Cascade MCM10 | boiler | 121 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus |
Cascade MCM10 | boiler | 121 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff |
Cascade MCM10 | boiler | 121 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle |
Cascade MCM10 | boiler | 121 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp |
Cascade MCM10 | boiler | 121 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | |
Cascade MCM10 | boiler | 121 | comfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | |
Cascade MCM10 | boiler | 121 | comfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | |
Cascade MCM10 | boiler | 121 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset |
Cascade MCM10 | boiler | 121 | chargeoptimization | charge optimization | boolean | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | |
Cascade MCM10 | boiler | 121 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower |
Cascade MCM10 | boiler | 121 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp |
Cascade MCM10 | boiler | 121 | circpump | circulation pump available | boolean | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | |
Cascade MCM10 | boiler | 121 | chargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | |
Cascade MCM10 | boiler | 121 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston |
Cascade MCM10 | boiler | 121 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff |
Cascade MCM10 | boiler | 121 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp |
Cascade MCM10 | boiler | 121 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | |
Cascade MCM10 | boiler | 121 | circ | circulation active | boolean | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | |
Cascade MCM10 | boiler | 121 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp |
Cascade MCM10 | boiler | 121 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 |
Cascade MCM10 | boiler | 121 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow |
Cascade MCM10 | boiler | 121 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 |
Cascade MCM10 | boiler | 121 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 |
Cascade MCM10 | boiler | 121 | activated | activated | boolean | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | |
Cascade MCM10 | boiler | 121 | onetime | one time charging | boolean | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | |
Cascade MCM10 | boiler | 121 | disinfecting | disinfecting | boolean | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | |
Cascade MCM10 | boiler | 121 | charging | charging | boolean | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | |
Cascade MCM10 | boiler | 121 | recharging | recharging | boolean | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | |
Cascade MCM10 | boiler | 121 | tempok | temperature ok | boolean | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | |
Cascade MCM10 | boiler | 121 | active | active | boolean | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | |
Cascade MCM10 | boiler | 121 | 3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | |
Cascade MCM10 | boiler | 121 | setpumppower | set pump power | uint8 (>=0<=100) | % | False | sensor.boiler_dhw_set_pump_power | sensor.boiler_dhw_setpumppower |
Cascade MCM10 | boiler | 121 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp |
Cascade MCM10 | boiler | 121 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp |
Cascade MCM10 | boiler | 121 | starts | starts | uint24 (>=0<=16777213) | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | |
Cascade MCM10 | boiler | 121 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm |
Cascade MCM10 | boiler | 121 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower |
Cascade MCM10 | boiler | 121 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
Cascade MCM10 | boiler | 121 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat |
Cascade MCM10 | boiler | 121 | nrgdhw | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrgdhw |
Proline | boiler | 122 | reset | reset | cmd [-|maintenance|error|history|message] | True | sensor.boiler_reset | sensor.boiler_reset | |
Proline | boiler | 122 | heatingoff | force heating off | boolean | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
Proline | boiler | 122 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
Proline | boiler | 122 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
Proline | boiler | 122 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
Proline | boiler | 122 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
Proline | boiler | 122 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
Proline | boiler | 122 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
Proline | boiler | 122 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
Proline | boiler | 122 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
Proline | boiler | 122 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
Proline | boiler | 122 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
Proline | boiler | 122 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
Proline | boiler | 122 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
Proline | boiler | 122 | burngas | gas | boolean | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
Proline | boiler | 122 | burngas2 | gas stage 2 | boolean | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
Proline | boiler | 122 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr |
Proline | boiler | 122 | fanwork | fan | boolean | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
Proline | boiler | 122 | ignwork | ignition | boolean | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
Proline | boiler | 122 | oilpreheat | oil preheating | boolean | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
Proline | boiler | 122 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower |
Proline | boiler | 122 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower |
Proline | boiler | 122 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod |
Proline | boiler | 122 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
Proline | boiler | 122 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock |
Proline | boiler | 122 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
Proline | boiler | 122 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
Proline | boiler | 122 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
Proline | boiler | 122 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
Proline | boiler | 122 | curveon | heatingcurve on | boolean | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | |
Proline | boiler | 122 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase |
Proline | boiler | 122 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend |
Proline | boiler | 122 | summertemp | summer temperature | uint8 (>=0<=30) | C | True | number.boiler_summer_temperature | number.boiler_summertemp |
Proline | boiler | 122 | nofrostmode | nofrost mode | boolean | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | |
Proline | boiler | 122 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp |
Proline | boiler | 122 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
Proline | boiler | 122 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
Proline | boiler | 122 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
Proline | boiler | 122 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
Proline | boiler | 122 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
Proline | boiler | 122 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
Proline | boiler | 122 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
Proline | boiler | 122 | setflowtemp | set flow temperature | uint8 (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
Proline | boiler | 122 | setburnpow | burner set power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
Proline | boiler | 122 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
Proline | boiler | 122 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
Proline | boiler | 122 | burnstarts | burner starts | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
Proline | boiler | 122 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
Proline | boiler | 122 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
Proline | boiler | 122 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
Proline | boiler | 122 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
Proline | boiler | 122 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
Proline | boiler | 122 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
Proline | boiler | 122 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
Proline | boiler | 122 | servicecodenumber | service code number | uint16 (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
Proline | boiler | 122 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
Proline | boiler | 122 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
Proline | boiler | 122 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
Proline | boiler | 122 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
Proline | boiler | 122 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
Proline | boiler | 122 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
Proline | boiler | 122 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat |
Proline | boiler | 122 | meterdhw | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meterdhw |
Proline | boiler | 122 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat |
Proline | boiler | 122 | gasmeterdhw | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeterdhw |
Proline | boiler | 122 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 |
Proline | boiler | 122 | nrgdhw2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrgdhw2 |
Proline | boiler | 122 | tapactivated | turn on/off | boolean | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | |
Proline | boiler | 122 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp |
Proline | boiler | 122 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp |
Proline | boiler | 122 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow |
Proline | boiler | 122 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus |
Proline | boiler | 122 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff |
Proline | boiler | 122 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle |
Proline | boiler | 122 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp |
Proline | boiler | 122 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | |
Proline | boiler | 122 | comfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | |
Proline | boiler | 122 | comfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | |
Proline | boiler | 122 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset |
Proline | boiler | 122 | chargeoptimization | charge optimization | boolean | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | |
Proline | boiler | 122 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower |
Proline | boiler | 122 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp |
Proline | boiler | 122 | circpump | circulation pump available | boolean | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | |
Proline | boiler | 122 | chargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | |
Proline | boiler | 122 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston |
Proline | boiler | 122 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff |
Proline | boiler | 122 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp |
Proline | boiler | 122 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | |
Proline | boiler | 122 | circ | circulation active | boolean | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | |
Proline | boiler | 122 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp |
Proline | boiler | 122 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 |
Proline | boiler | 122 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow |
Proline | boiler | 122 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 |
Proline | boiler | 122 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 |
Proline | boiler | 122 | activated | activated | boolean | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | |
Proline | boiler | 122 | onetime | one time charging | boolean | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | |
Proline | boiler | 122 | disinfecting | disinfecting | boolean | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | |
Proline | boiler | 122 | charging | charging | boolean | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | |
Proline | boiler | 122 | recharging | recharging | boolean | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | |
Proline | boiler | 122 | tempok | temperature ok | boolean | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | |
Proline | boiler | 122 | active | active | boolean | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | |
Proline | boiler | 122 | 3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | |
Proline | boiler | 122 | setpumppower | set pump power | uint8 (>=0<=100) | % | False | sensor.boiler_dhw_set_pump_power | sensor.boiler_dhw_setpumppower |
Proline | boiler | 122 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp |
Proline | boiler | 122 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp |
Proline | boiler | 122 | starts | starts | uint24 (>=0<=16777213) | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | |
Proline | boiler | 122 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm |
Proline | boiler | 122 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower |
Proline | boiler | 122 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
Proline | boiler | 122 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat |
Proline | boiler | 122 | nrgdhw | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrgdhw |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | reset | reset | cmd [-|maintenance|error|history|message] | True | sensor.boiler_reset | sensor.boiler_reset | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | heatingoff | force heating off | boolean | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | burngas | gas | boolean | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | burngas2 | gas stage 2 | boolean | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | fanwork | fan | boolean | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | ignwork | ignition | boolean | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | oilpreheat | oil preheating | boolean | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | curveon | heatingcurve on | boolean | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | summertemp | summer temperature | uint8 (>=0<=30) | C | True | number.boiler_summer_temperature | number.boiler_summertemp |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | nofrostmode | nofrost mode | boolean | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | setflowtemp | set flow temperature | uint8 (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | setburnpow | burner set power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | burnstarts | burner starts | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | servicecodenumber | service code number | uint16 (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | meterdhw | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meterdhw |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | gasmeterdhw | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeterdhw |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | nrgdhw2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrgdhw2 |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | tapactivated | turn on/off | boolean | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | comfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | comfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | chargeoptimization | charge optimization | boolean | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | circpump | circulation pump available | boolean | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | chargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | circ | circulation active | boolean | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | activated | activated | boolean | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | onetime | one time charging | boolean | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | disinfecting | disinfecting | boolean | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | charging | charging | boolean | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | recharging | recharging | boolean | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | tempok | temperature ok | boolean | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | active | active | boolean | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | 3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | setpumppower | set pump power | uint8 (>=0<=100) | % | False | sensor.boiler_dhw_set_pump_power | sensor.boiler_dhw_setpumppower |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | starts | starts | uint24 (>=0<=16777213) | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | nrgdhw | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrgdhw |
GB212 | boiler | 131 | reset | reset | cmd [-|maintenance|error|history|message] | True | sensor.boiler_reset | sensor.boiler_reset | |
GB212 | boiler | 131 | heatingoff | force heating off | boolean | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
GB212 | boiler | 131 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
GB212 | boiler | 131 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
GB212 | boiler | 131 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
GB212 | boiler | 131 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
GB212 | boiler | 131 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
GB212 | boiler | 131 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
GB212 | boiler | 131 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
GB212 | boiler | 131 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
GB212 | boiler | 131 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
GB212 | boiler | 131 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
GB212 | boiler | 131 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
GB212 | boiler | 131 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
GB212 | boiler | 131 | burngas | gas | boolean | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
GB212 | boiler | 131 | burngas2 | gas stage 2 | boolean | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
GB212 | boiler | 131 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr |
GB212 | boiler | 131 | fanwork | fan | boolean | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
GB212 | boiler | 131 | ignwork | ignition | boolean | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
GB212 | boiler | 131 | oilpreheat | oil preheating | boolean | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
GB212 | boiler | 131 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower |
GB212 | boiler | 131 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower |
GB212 | boiler | 131 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod |
GB212 | boiler | 131 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
GB212 | boiler | 131 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock |
GB212 | boiler | 131 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
GB212 | boiler | 131 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
GB212 | boiler | 131 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
GB212 | boiler | 131 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
GB212 | boiler | 131 | curveon | heatingcurve on | boolean | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | |
GB212 | boiler | 131 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase |
GB212 | boiler | 131 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend |
GB212 | boiler | 131 | summertemp | summer temperature | uint8 (>=0<=30) | C | True | number.boiler_summer_temperature | number.boiler_summertemp |
GB212 | boiler | 131 | nofrostmode | nofrost mode | boolean | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | |
GB212 | boiler | 131 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp |
GB212 | boiler | 131 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
GB212 | boiler | 131 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
GB212 | boiler | 131 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
GB212 | boiler | 131 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
GB212 | boiler | 131 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
GB212 | boiler | 131 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
GB212 | boiler | 131 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
GB212 | boiler | 131 | setflowtemp | set flow temperature | uint8 (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
GB212 | boiler | 131 | setburnpow | burner set power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
GB212 | boiler | 131 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
GB212 | boiler | 131 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
GB212 | boiler | 131 | burnstarts | burner starts | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
GB212 | boiler | 131 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
GB212 | boiler | 131 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
GB212 | boiler | 131 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
GB212 | boiler | 131 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
GB212 | boiler | 131 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
GB212 | boiler | 131 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
GB212 | boiler | 131 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
GB212 | boiler | 131 | servicecodenumber | service code number | uint16 (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
GB212 | boiler | 131 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
GB212 | boiler | 131 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
GB212 | boiler | 131 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
GB212 | boiler | 131 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
GB212 | boiler | 131 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
GB212 | boiler | 131 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
GB212 | boiler | 131 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat |
GB212 | boiler | 131 | meterdhw | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meterdhw |
GB212 | boiler | 131 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat |
GB212 | boiler | 131 | gasmeterdhw | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeterdhw |
GB212 | boiler | 131 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 |
GB212 | boiler | 131 | nrgdhw2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrgdhw2 |
GB212 | boiler | 131 | tapactivated | turn on/off | boolean | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | |
GB212 | boiler | 131 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp |
GB212 | boiler | 131 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp |
GB212 | boiler | 131 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow |
GB212 | boiler | 131 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus |
GB212 | boiler | 131 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff |
GB212 | boiler | 131 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle |
GB212 | boiler | 131 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp |
GB212 | boiler | 131 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | |
GB212 | boiler | 131 | comfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | |
GB212 | boiler | 131 | comfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | |
GB212 | boiler | 131 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset |
GB212 | boiler | 131 | chargeoptimization | charge optimization | boolean | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | |
GB212 | boiler | 131 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower |
GB212 | boiler | 131 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp |
GB212 | boiler | 131 | circpump | circulation pump available | boolean | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | |
GB212 | boiler | 131 | chargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | |
GB212 | boiler | 131 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston |
GB212 | boiler | 131 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff |
GB212 | boiler | 131 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp |
GB212 | boiler | 131 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | |
GB212 | boiler | 131 | circ | circulation active | boolean | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | |
GB212 | boiler | 131 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp |
GB212 | boiler | 131 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 |
GB212 | boiler | 131 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow |
GB212 | boiler | 131 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 |
GB212 | boiler | 131 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 |
GB212 | boiler | 131 | activated | activated | boolean | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | |
GB212 | boiler | 131 | onetime | one time charging | boolean | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | |
GB212 | boiler | 131 | disinfecting | disinfecting | boolean | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | |
GB212 | boiler | 131 | charging | charging | boolean | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | |
GB212 | boiler | 131 | recharging | recharging | boolean | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | |
GB212 | boiler | 131 | tempok | temperature ok | boolean | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | |
GB212 | boiler | 131 | active | active | boolean | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | |
GB212 | boiler | 131 | 3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | |
GB212 | boiler | 131 | setpumppower | set pump power | uint8 (>=0<=100) | % | False | sensor.boiler_dhw_set_pump_power | sensor.boiler_dhw_setpumppower |
GB212 | boiler | 131 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp |
GB212 | boiler | 131 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp |
GB212 | boiler | 131 | starts | starts | uint24 (>=0<=16777213) | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | |
GB212 | boiler | 131 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm |
GB212 | boiler | 131 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower |
GB212 | boiler | 131 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
GB212 | boiler | 131 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat |
GB212 | boiler | 131 | nrgdhw | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrgdhw |
GC7000F | boiler | 132 | reset | reset | cmd [-|maintenance|error|history|message] | True | sensor.boiler_reset | sensor.boiler_reset | |
GC7000F | boiler | 132 | heatingoff | force heating off | boolean | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
GC7000F | boiler | 132 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
GC7000F | boiler | 132 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
GC7000F | boiler | 132 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
GC7000F | boiler | 132 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
GC7000F | boiler | 132 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
GC7000F | boiler | 132 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
GC7000F | boiler | 132 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
GC7000F | boiler | 132 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
GC7000F | boiler | 132 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
GC7000F | boiler | 132 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
GC7000F | boiler | 132 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
GC7000F | boiler | 132 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
GC7000F | boiler | 132 | burngas | gas | boolean | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
GC7000F | boiler | 132 | burngas2 | gas stage 2 | boolean | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
GC7000F | boiler | 132 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr |
GC7000F | boiler | 132 | fanwork | fan | boolean | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
GC7000F | boiler | 132 | ignwork | ignition | boolean | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
GC7000F | boiler | 132 | oilpreheat | oil preheating | boolean | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
GC7000F | boiler | 132 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower |
GC7000F | boiler | 132 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower |
GC7000F | boiler | 132 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod |
GC7000F | boiler | 132 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
GC7000F | boiler | 132 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock |
GC7000F | boiler | 132 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
GC7000F | boiler | 132 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
GC7000F | boiler | 132 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
GC7000F | boiler | 132 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
GC7000F | boiler | 132 | curveon | heatingcurve on | boolean | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | |
GC7000F | boiler | 132 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase |
GC7000F | boiler | 132 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend |
GC7000F | boiler | 132 | summertemp | summer temperature | uint8 (>=0<=30) | C | True | number.boiler_summer_temperature | number.boiler_summertemp |
GC7000F | boiler | 132 | nofrostmode | nofrost mode | boolean | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | |
GC7000F | boiler | 132 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp |
GC7000F | boiler | 132 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
GC7000F | boiler | 132 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
GC7000F | boiler | 132 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
GC7000F | boiler | 132 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
GC7000F | boiler | 132 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
GC7000F | boiler | 132 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
GC7000F | boiler | 132 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
GC7000F | boiler | 132 | setflowtemp | set flow temperature | uint8 (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
GC7000F | boiler | 132 | setburnpow | burner set power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
GC7000F | boiler | 132 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
GC7000F | boiler | 132 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
GC7000F | boiler | 132 | burnstarts | burner starts | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
GC7000F | boiler | 132 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
GC7000F | boiler | 132 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
GC7000F | boiler | 132 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
GC7000F | boiler | 132 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
GC7000F | boiler | 132 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
GC7000F | boiler | 132 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
GC7000F | boiler | 132 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
GC7000F | boiler | 132 | servicecodenumber | service code number | uint16 (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
GC7000F | boiler | 132 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
GC7000F | boiler | 132 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
GC7000F | boiler | 132 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
GC7000F | boiler | 132 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
GC7000F | boiler | 132 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
GC7000F | boiler | 132 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
GC7000F | boiler | 132 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat |
GC7000F | boiler | 132 | meterdhw | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meterdhw |
GC7000F | boiler | 132 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat |
GC7000F | boiler | 132 | gasmeterdhw | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeterdhw |
GC7000F | boiler | 132 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 |
GC7000F | boiler | 132 | nrgdhw2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrgdhw2 |
GC7000F | boiler | 132 | tapactivated | turn on/off | boolean | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | |
GC7000F | boiler | 132 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp |
GC7000F | boiler | 132 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp |
GC7000F | boiler | 132 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow |
GC7000F | boiler | 132 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus |
GC7000F | boiler | 132 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff |
GC7000F | boiler | 132 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle |
GC7000F | boiler | 132 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp |
GC7000F | boiler | 132 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | |
GC7000F | boiler | 132 | comfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | |
GC7000F | boiler | 132 | comfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | |
GC7000F | boiler | 132 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset |
GC7000F | boiler | 132 | chargeoptimization | charge optimization | boolean | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | |
GC7000F | boiler | 132 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower |
GC7000F | boiler | 132 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp |
GC7000F | boiler | 132 | circpump | circulation pump available | boolean | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | |
GC7000F | boiler | 132 | chargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | |
GC7000F | boiler | 132 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston |
GC7000F | boiler | 132 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff |
GC7000F | boiler | 132 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp |
GC7000F | boiler | 132 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | |
GC7000F | boiler | 132 | circ | circulation active | boolean | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | |
GC7000F | boiler | 132 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp |
GC7000F | boiler | 132 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 |
GC7000F | boiler | 132 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow |
GC7000F | boiler | 132 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 |
GC7000F | boiler | 132 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 |
GC7000F | boiler | 132 | activated | activated | boolean | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | |
GC7000F | boiler | 132 | onetime | one time charging | boolean | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | |
GC7000F | boiler | 132 | disinfecting | disinfecting | boolean | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | |
GC7000F | boiler | 132 | charging | charging | boolean | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | |
GC7000F | boiler | 132 | recharging | recharging | boolean | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | |
GC7000F | boiler | 132 | tempok | temperature ok | boolean | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | |
GC7000F | boiler | 132 | active | active | boolean | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | |
GC7000F | boiler | 132 | 3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | |
GC7000F | boiler | 132 | setpumppower | set pump power | uint8 (>=0<=100) | % | False | sensor.boiler_dhw_set_pump_power | sensor.boiler_dhw_setpumppower |
GC7000F | boiler | 132 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp |
GC7000F | boiler | 132 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp |
GC7000F | boiler | 132 | starts | starts | uint24 (>=0<=16777213) | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | |
GC7000F | boiler | 132 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm |
GC7000F | boiler | 132 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower |
GC7000F | boiler | 132 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
GC7000F | boiler | 132 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat |
GC7000F | boiler | 132 | nrgdhw | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrgdhw |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | reset | reset | cmd [-|maintenance|error|history|message] | True | sensor.boiler_reset | sensor.boiler_reset | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | heatingoff | force heating off | boolean | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | burngas | gas | boolean | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | burngas2 | gas stage 2 | boolean | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | fanwork | fan | boolean | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | ignwork | ignition | boolean | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | oilpreheat | oil preheating | boolean | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | curveon | heatingcurve on | boolean | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | summertemp | summer temperature | uint8 (>=0<=30) | C | True | number.boiler_summer_temperature | number.boiler_summertemp |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | nofrostmode | nofrost mode | boolean | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | setflowtemp | set flow temperature | uint8 (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | setburnpow | burner set power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | burnstarts | burner starts | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | servicecodenumber | service code number | uint16 (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | meterdhw | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meterdhw |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | gasmeterdhw | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeterdhw |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | nrgdhw2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrgdhw2 |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | tapactivated | turn on/off | boolean | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | comfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | comfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | chargeoptimization | charge optimization | boolean | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | circpump | circulation pump available | boolean | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | chargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | circ | circulation active | boolean | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | activated | activated | boolean | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | onetime | one time charging | boolean | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | disinfecting | disinfecting | boolean | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | charging | charging | boolean | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | recharging | recharging | boolean | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | tempok | temperature ok | boolean | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | active | active | boolean | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | 3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | setpumppower | set pump power | uint8 (>=0<=100) | % | False | sensor.boiler_dhw_set_pump_power | sensor.boiler_dhw_setpumppower |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | starts | starts | uint24 (>=0<=16777213) | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | nrgdhw | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrgdhw |
Greenstar 30Ri Compact | boiler | 154 | reset | reset | cmd [-|maintenance|error|history|message] | True | sensor.boiler_reset | sensor.boiler_reset | |
Greenstar 30Ri Compact | boiler | 154 | heatingoff | force heating off | boolean | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
Greenstar 30Ri Compact | boiler | 154 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
Greenstar 30Ri Compact | boiler | 154 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
Greenstar 30Ri Compact | boiler | 154 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
Greenstar 30Ri Compact | boiler | 154 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
Greenstar 30Ri Compact | boiler | 154 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
Greenstar 30Ri Compact | boiler | 154 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
Greenstar 30Ri Compact | boiler | 154 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
Greenstar 30Ri Compact | boiler | 154 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
Greenstar 30Ri Compact | boiler | 154 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
Greenstar 30Ri Compact | boiler | 154 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
Greenstar 30Ri Compact | boiler | 154 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
Greenstar 30Ri Compact | boiler | 154 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
Greenstar 30Ri Compact | boiler | 154 | burngas | gas | boolean | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
Greenstar 30Ri Compact | boiler | 154 | burngas2 | gas stage 2 | boolean | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
Greenstar 30Ri Compact | boiler | 154 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr |
Greenstar 30Ri Compact | boiler | 154 | fanwork | fan | boolean | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
Greenstar 30Ri Compact | boiler | 154 | ignwork | ignition | boolean | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
Greenstar 30Ri Compact | boiler | 154 | oilpreheat | oil preheating | boolean | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
Greenstar 30Ri Compact | boiler | 154 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower |
Greenstar 30Ri Compact | boiler | 154 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower |
Greenstar 30Ri Compact | boiler | 154 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod |
Greenstar 30Ri Compact | boiler | 154 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
Greenstar 30Ri Compact | boiler | 154 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock |
Greenstar 30Ri Compact | boiler | 154 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
Greenstar 30Ri Compact | boiler | 154 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
Greenstar 30Ri Compact | boiler | 154 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
Greenstar 30Ri Compact | boiler | 154 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
Greenstar 30Ri Compact | boiler | 154 | curveon | heatingcurve on | boolean | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | |
Greenstar 30Ri Compact | boiler | 154 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase |
Greenstar 30Ri Compact | boiler | 154 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend |
Greenstar 30Ri Compact | boiler | 154 | summertemp | summer temperature | uint8 (>=0<=30) | C | True | number.boiler_summer_temperature | number.boiler_summertemp |
Greenstar 30Ri Compact | boiler | 154 | nofrostmode | nofrost mode | boolean | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | |
Greenstar 30Ri Compact | boiler | 154 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp |
Greenstar 30Ri Compact | boiler | 154 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
Greenstar 30Ri Compact | boiler | 154 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
Greenstar 30Ri Compact | boiler | 154 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
Greenstar 30Ri Compact | boiler | 154 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
Greenstar 30Ri Compact | boiler | 154 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
Greenstar 30Ri Compact | boiler | 154 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
Greenstar 30Ri Compact | boiler | 154 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
Greenstar 30Ri Compact | boiler | 154 | setflowtemp | set flow temperature | uint8 (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
Greenstar 30Ri Compact | boiler | 154 | setburnpow | burner set power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
Greenstar 30Ri Compact | boiler | 154 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
Greenstar 30Ri Compact | boiler | 154 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
Greenstar 30Ri Compact | boiler | 154 | burnstarts | burner starts | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
Greenstar 30Ri Compact | boiler | 154 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
Greenstar 30Ri Compact | boiler | 154 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
Greenstar 30Ri Compact | boiler | 154 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
Greenstar 30Ri Compact | boiler | 154 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
Greenstar 30Ri Compact | boiler | 154 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
Greenstar 30Ri Compact | boiler | 154 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
Greenstar 30Ri Compact | boiler | 154 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
Greenstar 30Ri Compact | boiler | 154 | servicecodenumber | service code number | uint16 (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
Greenstar 30Ri Compact | boiler | 154 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
Greenstar 30Ri Compact | boiler | 154 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
Greenstar 30Ri Compact | boiler | 154 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
Greenstar 30Ri Compact | boiler | 154 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
Greenstar 30Ri Compact | boiler | 154 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
Greenstar 30Ri Compact | boiler | 154 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
Greenstar 30Ri Compact | boiler | 154 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat |
Greenstar 30Ri Compact | boiler | 154 | meterdhw | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meterdhw |
Greenstar 30Ri Compact | boiler | 154 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat |
Greenstar 30Ri Compact | boiler | 154 | gasmeterdhw | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeterdhw |
Greenstar 30Ri Compact | boiler | 154 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 |
Greenstar 30Ri Compact | boiler | 154 | nrgdhw2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrgdhw2 |
Greenstar 30Ri Compact | boiler | 154 | tapactivated | turn on/off | boolean | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | |
Greenstar 30Ri Compact | boiler | 154 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp |
Greenstar 30Ri Compact | boiler | 154 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp |
Greenstar 30Ri Compact | boiler | 154 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow |
Greenstar 30Ri Compact | boiler | 154 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus |
Greenstar 30Ri Compact | boiler | 154 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff |
Greenstar 30Ri Compact | boiler | 154 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle |
Greenstar 30Ri Compact | boiler | 154 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp |
Greenstar 30Ri Compact | boiler | 154 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | |
Greenstar 30Ri Compact | boiler | 154 | comfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | |
Greenstar 30Ri Compact | boiler | 154 | comfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | |
Greenstar 30Ri Compact | boiler | 154 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset |
Greenstar 30Ri Compact | boiler | 154 | chargeoptimization | charge optimization | boolean | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | |
Greenstar 30Ri Compact | boiler | 154 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower |
Greenstar 30Ri Compact | boiler | 154 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp |
Greenstar 30Ri Compact | boiler | 154 | circpump | circulation pump available | boolean | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | |
Greenstar 30Ri Compact | boiler | 154 | chargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | |
Greenstar 30Ri Compact | boiler | 154 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston |
Greenstar 30Ri Compact | boiler | 154 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff |
Greenstar 30Ri Compact | boiler | 154 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp |
Greenstar 30Ri Compact | boiler | 154 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | |
Greenstar 30Ri Compact | boiler | 154 | circ | circulation active | boolean | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | |
Greenstar 30Ri Compact | boiler | 154 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp |
Greenstar 30Ri Compact | boiler | 154 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 |
Greenstar 30Ri Compact | boiler | 154 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow |
Greenstar 30Ri Compact | boiler | 154 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 |
Greenstar 30Ri Compact | boiler | 154 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 |
Greenstar 30Ri Compact | boiler | 154 | activated | activated | boolean | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | |
Greenstar 30Ri Compact | boiler | 154 | onetime | one time charging | boolean | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | |
Greenstar 30Ri Compact | boiler | 154 | disinfecting | disinfecting | boolean | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | |
Greenstar 30Ri Compact | boiler | 154 | charging | charging | boolean | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | |
Greenstar 30Ri Compact | boiler | 154 | recharging | recharging | boolean | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | |
Greenstar 30Ri Compact | boiler | 154 | tempok | temperature ok | boolean | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | |
Greenstar 30Ri Compact | boiler | 154 | active | active | boolean | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | |
Greenstar 30Ri Compact | boiler | 154 | 3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | |
Greenstar 30Ri Compact | boiler | 154 | setpumppower | set pump power | uint8 (>=0<=100) | % | False | sensor.boiler_dhw_set_pump_power | sensor.boiler_dhw_setpumppower |
Greenstar 30Ri Compact | boiler | 154 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp |
Greenstar 30Ri Compact | boiler | 154 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp |
Greenstar 30Ri Compact | boiler | 154 | starts | starts | uint24 (>=0<=16777213) | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | |
Greenstar 30Ri Compact | boiler | 154 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm |
Greenstar 30Ri Compact | boiler | 154 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower |
Greenstar 30Ri Compact | boiler | 154 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
Greenstar 30Ri Compact | boiler | 154 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat |
Greenstar 30Ri Compact | boiler | 154 | nrgdhw | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrgdhw |
Cerapur Aero | boiler | 167 | reset | reset | cmd [-|maintenance|error|history|message] | True | sensor.boiler_reset | sensor.boiler_reset | |
Cerapur Aero | boiler | 167 | heatingoff | force heating off | boolean | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
Cerapur Aero | boiler | 167 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
Cerapur Aero | boiler | 167 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
Cerapur Aero | boiler | 167 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
Cerapur Aero | boiler | 167 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
Cerapur Aero | boiler | 167 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
Cerapur Aero | boiler | 167 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
Cerapur Aero | boiler | 167 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
Cerapur Aero | boiler | 167 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
Cerapur Aero | boiler | 167 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
Cerapur Aero | boiler | 167 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
Cerapur Aero | boiler | 167 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
Cerapur Aero | boiler | 167 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
Cerapur Aero | boiler | 167 | burngas | gas | boolean | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
Cerapur Aero | boiler | 167 | burngas2 | gas stage 2 | boolean | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
Cerapur Aero | boiler | 167 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr |
Cerapur Aero | boiler | 167 | fanwork | fan | boolean | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
Cerapur Aero | boiler | 167 | ignwork | ignition | boolean | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
Cerapur Aero | boiler | 167 | oilpreheat | oil preheating | boolean | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
Cerapur Aero | boiler | 167 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower |
Cerapur Aero | boiler | 167 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower |
Cerapur Aero | boiler | 167 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod |
Cerapur Aero | boiler | 167 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
Cerapur Aero | boiler | 167 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock |
Cerapur Aero | boiler | 167 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
Cerapur Aero | boiler | 167 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
Cerapur Aero | boiler | 167 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
Cerapur Aero | boiler | 167 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
Cerapur Aero | boiler | 167 | curveon | heatingcurve on | boolean | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | |
Cerapur Aero | boiler | 167 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase |
Cerapur Aero | boiler | 167 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend |
Cerapur Aero | boiler | 167 | summertemp | summer temperature | uint8 (>=0<=30) | C | True | number.boiler_summer_temperature | number.boiler_summertemp |
Cerapur Aero | boiler | 167 | nofrostmode | nofrost mode | boolean | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | |
Cerapur Aero | boiler | 167 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp |
Cerapur Aero | boiler | 167 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
Cerapur Aero | boiler | 167 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
Cerapur Aero | boiler | 167 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
Cerapur Aero | boiler | 167 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
Cerapur Aero | boiler | 167 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
Cerapur Aero | boiler | 167 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
Cerapur Aero | boiler | 167 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
Cerapur Aero | boiler | 167 | setflowtemp | set flow temperature | uint8 (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
Cerapur Aero | boiler | 167 | setburnpow | burner set power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
Cerapur Aero | boiler | 167 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
Cerapur Aero | boiler | 167 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
Cerapur Aero | boiler | 167 | burnstarts | burner starts | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
Cerapur Aero | boiler | 167 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
Cerapur Aero | boiler | 167 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
Cerapur Aero | boiler | 167 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
Cerapur Aero | boiler | 167 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
Cerapur Aero | boiler | 167 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
Cerapur Aero | boiler | 167 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
Cerapur Aero | boiler | 167 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
Cerapur Aero | boiler | 167 | servicecodenumber | service code number | uint16 (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
Cerapur Aero | boiler | 167 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
Cerapur Aero | boiler | 167 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
Cerapur Aero | boiler | 167 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
Cerapur Aero | boiler | 167 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
Cerapur Aero | boiler | 167 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
Cerapur Aero | boiler | 167 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
Cerapur Aero | boiler | 167 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat |
Cerapur Aero | boiler | 167 | meterdhw | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meterdhw |
Cerapur Aero | boiler | 167 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat |
Cerapur Aero | boiler | 167 | gasmeterdhw | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeterdhw |
Cerapur Aero | boiler | 167 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 |
Cerapur Aero | boiler | 167 | nrgdhw2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrgdhw2 |
Cerapur Aero | boiler | 167 | tapactivated | turn on/off | boolean | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | |
Cerapur Aero | boiler | 167 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp |
Cerapur Aero | boiler | 167 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp |
Cerapur Aero | boiler | 167 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow |
Cerapur Aero | boiler | 167 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus |
Cerapur Aero | boiler | 167 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff |
Cerapur Aero | boiler | 167 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle |
Cerapur Aero | boiler | 167 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp |
Cerapur Aero | boiler | 167 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | |
Cerapur Aero | boiler | 167 | comfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | |
Cerapur Aero | boiler | 167 | comfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | |
Cerapur Aero | boiler | 167 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset |
Cerapur Aero | boiler | 167 | chargeoptimization | charge optimization | boolean | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | |
Cerapur Aero | boiler | 167 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower |
Cerapur Aero | boiler | 167 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp |
Cerapur Aero | boiler | 167 | circpump | circulation pump available | boolean | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | |
Cerapur Aero | boiler | 167 | chargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | |
Cerapur Aero | boiler | 167 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston |
Cerapur Aero | boiler | 167 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff |
Cerapur Aero | boiler | 167 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp |
Cerapur Aero | boiler | 167 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | |
Cerapur Aero | boiler | 167 | circ | circulation active | boolean | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | |
Cerapur Aero | boiler | 167 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp |
Cerapur Aero | boiler | 167 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 |
Cerapur Aero | boiler | 167 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow |
Cerapur Aero | boiler | 167 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 |
Cerapur Aero | boiler | 167 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 |
Cerapur Aero | boiler | 167 | activated | activated | boolean | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | |
Cerapur Aero | boiler | 167 | onetime | one time charging | boolean | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | |
Cerapur Aero | boiler | 167 | disinfecting | disinfecting | boolean | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | |
Cerapur Aero | boiler | 167 | charging | charging | boolean | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | |
Cerapur Aero | boiler | 167 | recharging | recharging | boolean | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | |
Cerapur Aero | boiler | 167 | tempok | temperature ok | boolean | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | |
Cerapur Aero | boiler | 167 | active | active | boolean | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | |
Cerapur Aero | boiler | 167 | 3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | |
Cerapur Aero | boiler | 167 | setpumppower | set pump power | uint8 (>=0<=100) | % | False | sensor.boiler_dhw_set_pump_power | sensor.boiler_dhw_setpumppower |
Cerapur Aero | boiler | 167 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp |
Cerapur Aero | boiler | 167 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp |
Cerapur Aero | boiler | 167 | starts | starts | uint24 (>=0<=16777213) | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | |
Cerapur Aero | boiler | 167 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm |
Cerapur Aero | boiler | 167 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower |
Cerapur Aero | boiler | 167 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
Cerapur Aero | boiler | 167 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat |
Cerapur Aero | boiler | 167 | nrgdhw | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrgdhw |
Hybrid Heatpump | boiler | 168 | reset | reset | cmd [-|maintenance|error|history|message] | True | sensor.boiler_reset | sensor.boiler_reset | |
Hybrid Heatpump | boiler | 168 | heatingoff | force heating off | boolean | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
Hybrid Heatpump | boiler | 168 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
Hybrid Heatpump | boiler | 168 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
Hybrid Heatpump | boiler | 168 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
Hybrid Heatpump | boiler | 168 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
Hybrid Heatpump | boiler | 168 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
Hybrid Heatpump | boiler | 168 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
Hybrid Heatpump | boiler | 168 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
Hybrid Heatpump | boiler | 168 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
Hybrid Heatpump | boiler | 168 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
Hybrid Heatpump | boiler | 168 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
Hybrid Heatpump | boiler | 168 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
Hybrid Heatpump | boiler | 168 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
Hybrid Heatpump | boiler | 168 | burngas | gas | boolean | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
Hybrid Heatpump | boiler | 168 | burngas2 | gas stage 2 | boolean | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
Hybrid Heatpump | boiler | 168 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr |
Hybrid Heatpump | boiler | 168 | fanwork | fan | boolean | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
Hybrid Heatpump | boiler | 168 | ignwork | ignition | boolean | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
Hybrid Heatpump | boiler | 168 | oilpreheat | oil preheating | boolean | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
Hybrid Heatpump | boiler | 168 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower |
Hybrid Heatpump | boiler | 168 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower |
Hybrid Heatpump | boiler | 168 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod |
Hybrid Heatpump | boiler | 168 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
Hybrid Heatpump | boiler | 168 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock |
Hybrid Heatpump | boiler | 168 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
Hybrid Heatpump | boiler | 168 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
Hybrid Heatpump | boiler | 168 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
Hybrid Heatpump | boiler | 168 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
Hybrid Heatpump | boiler | 168 | curveon | heatingcurve on | boolean | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | |
Hybrid Heatpump | boiler | 168 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase |
Hybrid Heatpump | boiler | 168 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend |
Hybrid Heatpump | boiler | 168 | summertemp | summer temperature | uint8 (>=0<=30) | C | True | number.boiler_summer_temperature | number.boiler_summertemp |
Hybrid Heatpump | boiler | 168 | nofrostmode | nofrost mode | boolean | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | |
Hybrid Heatpump | boiler | 168 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp |
Hybrid Heatpump | boiler | 168 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
Hybrid Heatpump | boiler | 168 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
Hybrid Heatpump | boiler | 168 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
Hybrid Heatpump | boiler | 168 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
Hybrid Heatpump | boiler | 168 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
Hybrid Heatpump | boiler | 168 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
Hybrid Heatpump | boiler | 168 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
Hybrid Heatpump | boiler | 168 | setflowtemp | set flow temperature | uint8 (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
Hybrid Heatpump | boiler | 168 | setburnpow | burner set power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
Hybrid Heatpump | boiler | 168 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
Hybrid Heatpump | boiler | 168 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
Hybrid Heatpump | boiler | 168 | burnstarts | burner starts | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
Hybrid Heatpump | boiler | 168 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
Hybrid Heatpump | boiler | 168 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
Hybrid Heatpump | boiler | 168 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
Hybrid Heatpump | boiler | 168 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
Hybrid Heatpump | boiler | 168 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
Hybrid Heatpump | boiler | 168 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
Hybrid Heatpump | boiler | 168 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
Hybrid Heatpump | boiler | 168 | servicecodenumber | service code number | uint16 (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
Hybrid Heatpump | boiler | 168 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
Hybrid Heatpump | boiler | 168 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
Hybrid Heatpump | boiler | 168 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
Hybrid Heatpump | boiler | 168 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
Hybrid Heatpump | boiler | 168 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
Hybrid Heatpump | boiler | 168 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
Hybrid Heatpump | boiler | 168 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat |
Hybrid Heatpump | boiler | 168 | meterdhw | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meterdhw |
Hybrid Heatpump | boiler | 168 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat |
Hybrid Heatpump | boiler | 168 | gasmeterdhw | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeterdhw |
Hybrid Heatpump | boiler | 168 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 |
Hybrid Heatpump | boiler | 168 | nrgdhw2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrgdhw2 |
Hybrid Heatpump | boiler | 168 | tapactivated | turn on/off | boolean | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | |
Hybrid Heatpump | boiler | 168 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp |
Hybrid Heatpump | boiler | 168 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp |
Hybrid Heatpump | boiler | 168 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow |
Hybrid Heatpump | boiler | 168 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus |
Hybrid Heatpump | boiler | 168 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff |
Hybrid Heatpump | boiler | 168 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle |
Hybrid Heatpump | boiler | 168 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp |
Hybrid Heatpump | boiler | 168 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | |
Hybrid Heatpump | boiler | 168 | comfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | |
Hybrid Heatpump | boiler | 168 | comfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | |
Hybrid Heatpump | boiler | 168 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset |
Hybrid Heatpump | boiler | 168 | chargeoptimization | charge optimization | boolean | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | |
Hybrid Heatpump | boiler | 168 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower |
Hybrid Heatpump | boiler | 168 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp |
Hybrid Heatpump | boiler | 168 | circpump | circulation pump available | boolean | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | |
Hybrid Heatpump | boiler | 168 | chargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | |
Hybrid Heatpump | boiler | 168 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston |
Hybrid Heatpump | boiler | 168 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff |
Hybrid Heatpump | boiler | 168 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp |
Hybrid Heatpump | boiler | 168 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | |
Hybrid Heatpump | boiler | 168 | circ | circulation active | boolean | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | |
Hybrid Heatpump | boiler | 168 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp |
Hybrid Heatpump | boiler | 168 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 |
Hybrid Heatpump | boiler | 168 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow |
Hybrid Heatpump | boiler | 168 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 |
Hybrid Heatpump | boiler | 168 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 |
Hybrid Heatpump | boiler | 168 | activated | activated | boolean | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | |
Hybrid Heatpump | boiler | 168 | onetime | one time charging | boolean | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | |
Hybrid Heatpump | boiler | 168 | disinfecting | disinfecting | boolean | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | |
Hybrid Heatpump | boiler | 168 | charging | charging | boolean | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | |
Hybrid Heatpump | boiler | 168 | recharging | recharging | boolean | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | |
Hybrid Heatpump | boiler | 168 | tempok | temperature ok | boolean | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | |
Hybrid Heatpump | boiler | 168 | active | active | boolean | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | |
Hybrid Heatpump | boiler | 168 | 3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | |
Hybrid Heatpump | boiler | 168 | setpumppower | set pump power | uint8 (>=0<=100) | % | False | sensor.boiler_dhw_set_pump_power | sensor.boiler_dhw_setpumppower |
Hybrid Heatpump | boiler | 168 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp |
Hybrid Heatpump | boiler | 168 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp |
Hybrid Heatpump | boiler | 168 | starts | starts | uint24 (>=0<=16777213) | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | |
Hybrid Heatpump | boiler | 168 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm |
Hybrid Heatpump | boiler | 168 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower |
Hybrid Heatpump | boiler | 168 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
Hybrid Heatpump | boiler | 168 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat |
Hybrid Heatpump | boiler | 168 | nrgdhw | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrgdhw |
Logano GB212 | boiler | 170 | reset | reset | cmd [-|maintenance|error|history|message] | True | sensor.boiler_reset | sensor.boiler_reset | |
Logano GB212 | boiler | 170 | heatingoff | force heating off | boolean | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
Logano GB212 | boiler | 170 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
Logano GB212 | boiler | 170 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
Logano GB212 | boiler | 170 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
Logano GB212 | boiler | 170 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
Logano GB212 | boiler | 170 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
Logano GB212 | boiler | 170 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
Logano GB212 | boiler | 170 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
Logano GB212 | boiler | 170 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
Logano GB212 | boiler | 170 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
Logano GB212 | boiler | 170 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
Logano GB212 | boiler | 170 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
Logano GB212 | boiler | 170 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
Logano GB212 | boiler | 170 | burngas | gas | boolean | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
Logano GB212 | boiler | 170 | burngas2 | gas stage 2 | boolean | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
Logano GB212 | boiler | 170 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr |
Logano GB212 | boiler | 170 | fanwork | fan | boolean | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
Logano GB212 | boiler | 170 | ignwork | ignition | boolean | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
Logano GB212 | boiler | 170 | oilpreheat | oil preheating | boolean | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
Logano GB212 | boiler | 170 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower |
Logano GB212 | boiler | 170 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower |
Logano GB212 | boiler | 170 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod |
Logano GB212 | boiler | 170 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
Logano GB212 | boiler | 170 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock |
Logano GB212 | boiler | 170 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
Logano GB212 | boiler | 170 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
Logano GB212 | boiler | 170 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
Logano GB212 | boiler | 170 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
Logano GB212 | boiler | 170 | curveon | heatingcurve on | boolean | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | |
Logano GB212 | boiler | 170 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase |
Logano GB212 | boiler | 170 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend |
Logano GB212 | boiler | 170 | summertemp | summer temperature | uint8 (>=0<=30) | C | True | number.boiler_summer_temperature | number.boiler_summertemp |
Logano GB212 | boiler | 170 | nofrostmode | nofrost mode | boolean | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | |
Logano GB212 | boiler | 170 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp |
Logano GB212 | boiler | 170 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
Logano GB212 | boiler | 170 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
Logano GB212 | boiler | 170 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
Logano GB212 | boiler | 170 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
Logano GB212 | boiler | 170 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
Logano GB212 | boiler | 170 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
Logano GB212 | boiler | 170 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
Logano GB212 | boiler | 170 | setflowtemp | set flow temperature | uint8 (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
Logano GB212 | boiler | 170 | setburnpow | burner set power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
Logano GB212 | boiler | 170 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
Logano GB212 | boiler | 170 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
Logano GB212 | boiler | 170 | burnstarts | burner starts | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
Logano GB212 | boiler | 170 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
Logano GB212 | boiler | 170 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
Logano GB212 | boiler | 170 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
Logano GB212 | boiler | 170 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
Logano GB212 | boiler | 170 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
Logano GB212 | boiler | 170 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
Logano GB212 | boiler | 170 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
Logano GB212 | boiler | 170 | servicecodenumber | service code number | uint16 (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
Logano GB212 | boiler | 170 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
Logano GB212 | boiler | 170 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
Logano GB212 | boiler | 170 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
Logano GB212 | boiler | 170 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
Logano GB212 | boiler | 170 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
Logano GB212 | boiler | 170 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
Logano GB212 | boiler | 170 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat |
Logano GB212 | boiler | 170 | meterdhw | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meterdhw |
Logano GB212 | boiler | 170 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat |
Logano GB212 | boiler | 170 | gasmeterdhw | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeterdhw |
Logano GB212 | boiler | 170 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 |
Logano GB212 | boiler | 170 | nrgdhw2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrgdhw2 |
Logano GB212 | boiler | 170 | tapactivated | turn on/off | boolean | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | |
Logano GB212 | boiler | 170 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp |
Logano GB212 | boiler | 170 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp |
Logano GB212 | boiler | 170 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow |
Logano GB212 | boiler | 170 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus |
Logano GB212 | boiler | 170 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff |
Logano GB212 | boiler | 170 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle |
Logano GB212 | boiler | 170 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp |
Logano GB212 | boiler | 170 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | |
Logano GB212 | boiler | 170 | comfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | |
Logano GB212 | boiler | 170 | comfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | |
Logano GB212 | boiler | 170 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset |
Logano GB212 | boiler | 170 | chargeoptimization | charge optimization | boolean | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | |
Logano GB212 | boiler | 170 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower |
Logano GB212 | boiler | 170 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp |
Logano GB212 | boiler | 170 | circpump | circulation pump available | boolean | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | |
Logano GB212 | boiler | 170 | chargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | |
Logano GB212 | boiler | 170 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston |
Logano GB212 | boiler | 170 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff |
Logano GB212 | boiler | 170 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp |
Logano GB212 | boiler | 170 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | |
Logano GB212 | boiler | 170 | circ | circulation active | boolean | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | |
Logano GB212 | boiler | 170 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp |
Logano GB212 | boiler | 170 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 |
Logano GB212 | boiler | 170 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow |
Logano GB212 | boiler | 170 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 |
Logano GB212 | boiler | 170 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 |
Logano GB212 | boiler | 170 | activated | activated | boolean | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | |
Logano GB212 | boiler | 170 | onetime | one time charging | boolean | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | |
Logano GB212 | boiler | 170 | disinfecting | disinfecting | boolean | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | |
Logano GB212 | boiler | 170 | charging | charging | boolean | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | |
Logano GB212 | boiler | 170 | recharging | recharging | boolean | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | |
Logano GB212 | boiler | 170 | tempok | temperature ok | boolean | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | |
Logano GB212 | boiler | 170 | active | active | boolean | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | |
Logano GB212 | boiler | 170 | 3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | |
Logano GB212 | boiler | 170 | setpumppower | set pump power | uint8 (>=0<=100) | % | False | sensor.boiler_dhw_set_pump_power | sensor.boiler_dhw_setpumppower |
Logano GB212 | boiler | 170 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp |
Logano GB212 | boiler | 170 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp |
Logano GB212 | boiler | 170 | starts | starts | uint24 (>=0<=16777213) | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | |
Logano GB212 | boiler | 170 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm |
Logano GB212 | boiler | 170 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower |
Logano GB212 | boiler | 170 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
Logano GB212 | boiler | 170 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat |
Logano GB212 | boiler | 170 | nrgdhw | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrgdhw |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | reset | reset | cmd [-|maintenance|error|history|message] | True | sensor.boiler_reset | sensor.boiler_reset | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | heatingoff | force heating off | boolean | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | setflowtemp | set flow temperature | uint8 (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | setburnpow | burner set power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | burnstarts | burner starts | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | servicecodenumber | service code number | uint16 (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgdhw | energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_dhw_energy | sensor.boiler_dhw_nrgdhw |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgheat | energy heating | uint24 (>=0<=167772) | kWh | False | sensor.boiler_energy_heating | sensor.boiler_nrgheat |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | metertotal | meter total | uint24 (>=0<=167772) | kWh | False | sensor.boiler_meter_total | sensor.boiler_metertotal |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | metercomp | meter compressor | uint24 (>=0<=167772) | kWh | False | sensor.boiler_meter_compressor | sensor.boiler_metercomp |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | metereheat | meter e-heater | uint24 (>=0<=167772) | kWh | False | sensor.boiler_meter_e-heater | sensor.boiler_metereheat |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | meterheat | meter heating | uint24 (>=0<=167772) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | meterdhw | meter | uint24 (>=0<=167772) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meterdhw |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | uptimetotal | heatpump total uptime | time (>=0<=279620) | minutes | False | sensor.boiler_heatpump_total_uptime | sensor.boiler_uptimetotal |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | uptimecontrol | total operating time heat | time (>=0<=279620) | minutes | False | sensor.boiler_total_operating_time_heat | sensor.boiler_uptimecontrol |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | uptimecompheating | operating time compressor heating | time (>=0<=279620) | minutes | False | sensor.boiler_operating_time_compressor_heating | sensor.boiler_uptimecompheating |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | uptimecompcooling | operating time compressor cooling | time (>=0<=279620) | minutes | False | sensor.boiler_operating_time_compressor_cooling | sensor.boiler_uptimecompcooling |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | uptimecompdhw | operating time compressor | time (>=0<=279620) | minutes | False | sensor.boiler_dhw_operating_time_compressor | sensor.boiler_dhw_uptimecompdhw |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | uptimecomppool | operating time compressor pool | time (>=0<=279620) | minutes | False | sensor.boiler_operating_time_compressor_pool | sensor.boiler_uptimecomppool |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | totalcompstarts | total compressor control starts | uint24 (>=0<=16777213) | False | sensor.boiler_total_compressor_control_starts | sensor.boiler_totalcompstarts | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | heatingstarts | heating control starts | uint24 (>=0<=16777213) | False | sensor.boiler_heating_control_starts | sensor.boiler_heatingstarts | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | coolingstarts | cooling control starts | uint24 (>=0<=16777213) | False | sensor.boiler_cooling_control_starts | sensor.boiler_coolingstarts | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | starts2 | control starts2 | uint24 (>=0<=16777213) | False | sensor.boiler_dhw_control_starts2 | sensor.boiler_dhw_starts2 | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | poolstarts | pool control starts | uint24 (>=0<=16777213) | False | sensor.boiler_pool_control_starts | sensor.boiler_poolstarts | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgconstotal | total energy consumption | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_total_energy_consumption | sensor.boiler_nrgconstotal |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgconscomptotal | total energy consumption compressor | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_total_energy_consumption_compressor | sensor.boiler_nrgconscomptotal |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgconscompheating | energy consumption compressor heating | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_energy_consumption_compressor_heating | sensor.boiler_nrgconscompheating |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgconscompdhw | energy consumption compressor | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_dhw_energy_consumption_compressor | sensor.boiler_dhw_nrgconscompdhw |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgconscompcooling | energy consumption compressor cooling | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_energy_consumption_compressor_cooling | sensor.boiler_nrgconscompcooling |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgconscomppool | energy consumption compressor pool | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_energy_consumption_compressor_pool | sensor.boiler_nrgconscomppool |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxelecheatnrgconstotal | total aux elec. heater energy consumption | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_total_aux_elec._heater_energy_consumption | sensor.boiler_auxelecheatnrgconstotal |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxelecheatnrgconsheating | aux elec. heater energy consumption heating | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_aux_elec._heater_energy_consumption_heating | sensor.boiler_auxelecheatnrgconsheating |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxelecheatnrgconsdhw | aux elec. heater energy consumption | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_dhw_aux_elec._heater_energy_consumption | sensor.boiler_dhw_auxelecheatnrgconsdhw |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxelecheatnrgconspool | aux elec. heater energy consumption pool | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_aux_elec._heater_energy_consumption_pool | sensor.boiler_auxelecheatnrgconspool |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgsupptotal | total energy supplied | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_total_energy_supplied | sensor.boiler_nrgsupptotal |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgsuppheating | total energy supplied heating | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_total_energy_supplied_heating | sensor.boiler_nrgsuppheating |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgsuppdhw | total energy warm supplied | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_dhw_total_energy_warm_supplied | sensor.boiler_dhw_nrgsuppdhw |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgsuppcooling | total energy supplied cooling | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_total_energy_supplied_cooling | sensor.boiler_nrgsuppcooling |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgsupppool | total energy supplied pool | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_total_energy_supplied_pool | sensor.boiler_nrgsupppool |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hppower | compressor power output | uint8 (>=0<=25) | kW | False | sensor.boiler_compressor_power_output | sensor.boiler_hppower |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpmaxpower | compressor max power | uint8 (>=0<=100) | % | True | number.boiler_compressor_max_power | number.boiler_hpmaxpower |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpsetdiffpress | set differental pressure | uint8 (>=150<=750) | mbar | True | number.boiler_set_differental_pressure | number.boiler_hpsetdiffpress |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpcompon | hp compressor | boolean | False | binary_sensor.boiler_hp_compressor | binary_sensor.boiler_hpcompon | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpactivity | compressor activity | enum [none|heating|cooling|hot water|pool|unknown|defrost] | False | sensor.boiler_compressor_activity | sensor.boiler_hpactivity | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpbrinepumpspd | brine pump speed | uint8 (>=0<=100) | % | False | sensor.boiler_brine_pump_speed | sensor.boiler_hpbrinepumpspd |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpswitchvalve | switch valve | boolean | False | binary_sensor.boiler_switch_valve | binary_sensor.boiler_hpswitchvalve | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpcompspd | compressor speed | uint8 (>=0<=100) | % | False | sensor.boiler_compressor_speed | sensor.boiler_hpcompspd |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpcircspd | circulation pump speed | uint8 (>=0<=100) | % | False | sensor.boiler_circulation_pump_speed | sensor.boiler_hpcircspd |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpbrinein | brine in/evaporator | int16 (>=-3199<=3199) | C | False | sensor.boiler_brine_in/evaporator | sensor.boiler_hpbrinein |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpbrineout | brine out/condenser | int16 (>=-3199<=3199) | C | False | sensor.boiler_brine_out/condenser | sensor.boiler_hpbrineout |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hptc0 | heat carrier return (TC0) | int16 (>=-3199<=3199) | C | False | sensor.boiler_heat_carrier_return_(TC0) | sensor.boiler_hptc0 |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hptc1 | heat carrier forward (TC1) | int16 (>=-3199<=3199) | C | False | sensor.boiler_heat_carrier_forward_(TC1) | sensor.boiler_hptc1 |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hptc3 | condenser temperature (TC3) | int16 (>=-3199<=3199) | C | False | sensor.boiler_condenser_temperature_(TC3) | sensor.boiler_hptc3 |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hptr1 | compressor temperature (TR1) | int16 (>=-3199<=3199) | C | False | sensor.boiler_compressor_temperature_(TR1) | sensor.boiler_hptr1 |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hptr3 | refrigerant temperature liquid side (condenser output) (TR3) | int16 (>=-3199<=3199) | C | False | sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3) | sensor.boiler_hptr3 |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hptr4 | evaporator inlet temperature (TR4) | int16 (>=-3199<=3199) | C | False | sensor.boiler_evaporator_inlet_temperature_(TR4) | sensor.boiler_hptr4 |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hptr5 | compressor inlet temperature (TR5) | int16 (>=-3199<=3199) | C | False | sensor.boiler_compressor_inlet_temperature_(TR5) | sensor.boiler_hptr5 |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hptr6 | compressor outlet temperature (TR6) | int16 (>=-3199<=3199) | C | False | sensor.boiler_compressor_outlet_temperature_(TR6) | sensor.boiler_hptr6 |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hptr7 | refrigerant temperature gas side (condenser input) (TR7) | int16 (>=-3199<=3199) | C | False | sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7) | sensor.boiler_hptr7 |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hptl2 | air inlet temperature (TL2) | int16 (>=-3199<=3199) | C | False | sensor.boiler_air_inlet_temperature_(TL2) | sensor.boiler_hptl2 |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hppl1 | low pressure side temperature (PL1) | int16 (>=-3199<=3199) | C | False | sensor.boiler_low_pressure_side_temperature_(PL1) | sensor.boiler_hppl1 |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpph1 | high pressure side temperature (PH1) | int16 (>=-3199<=3199) | C | False | sensor.boiler_high_pressure_side_temperature_(PH1) | sensor.boiler_hpph1 |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpta4 | drain pan temp (TA4) | int16 (>=-3199<=3199) | C | False | sensor.boiler_drain_pan_temp_(TA4) | sensor.boiler_hpta4 |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hptw1 | reservoir temp (TW1) | int16 (>=-3199<=3199) | C | False | sensor.boiler_reservoir_temp_(TW1) | sensor.boiler_hptw1 |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | poolsettemp | pool set temperature | uint8 (>=0<=127) | C | True | number.boiler_pool_set_temperature | number.boiler_poolsettemp |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hp4way | 4-way valve (VR4) | enum [cooling & defrost|heating & dhw] | False | sensor.boiler_4-way_valve_(VR4) | sensor.boiler_hp4way | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpin1opt | input 1 options | string | True | sensor.boiler_input_1_options | sensor.boiler_hpin1opt | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpin2opt | input 2 options | string | True | sensor.boiler_input_2_options | sensor.boiler_hpin2opt | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpin3opt | input 3 options | string | True | sensor.boiler_input_3_options | sensor.boiler_hpin3opt | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpin4opt | input 4 options | string | True | sensor.boiler_input_4_options | sensor.boiler_hpin4opt | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | maxheatcomp | heat limit compressor | enum [0 kW|2 kW|3 kW|4 kW|6 kW|9 kW] | True | select.boiler_heat_limit_compressor | select.boiler_maxheatcomp | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | maxheatheat | heat limit heating | enum [0 kW|2 kW|3 kW|4 kW|6 kW|9 kW] | True | select.boiler_heat_limit_heating | select.boiler_maxheatheat | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | maxheatdhw | heat limit | enum [0 kW|2 kW|3 kW|4 kW|6 kW|9 kW] | True | select.boiler_dhw_heat_limit | select.boiler_dhw_maxheatdhw | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | mandefrost | manual defrost | boolean | True | switch.boiler_manual_defrost | switch.boiler_mandefrost | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | pvcooling | cooling only with PV | boolean | True | switch.boiler_cooling_only_with_PV | switch.boiler_pvcooling | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxheateronly | aux heater only | boolean | True | switch.boiler_aux_heater_only | switch.boiler_auxheateronly | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxheateroff | disable aux heater | boolean | True | switch.boiler_disable_aux_heater | switch.boiler_auxheateroff | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxheaterstatus | aux heater status | uint8 (>=0<=100) | % | False | sensor.boiler_aux_heater_status | sensor.boiler_auxheaterstatus |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxheaterdelay | aux heater on delay | uint16 (>=10<=1000) | K*min | True | number.boiler_aux_heater_on_delay | number.boiler_auxheaterdelay |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxmaxlimit | aux heater max limit | uint8 (>=0<=10) | K | True | number.boiler_aux_heater_max_limit | number.boiler_auxmaxlimit |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxlimitstart | aux heater limit start | uint8 (>=0<=10) | K | True | number.boiler_aux_heater_limit_start | number.boiler_auxlimitstart |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxheatrmode | aux heater mode | enum [eco|comfort] | True | select.boiler_aux_heater_mode | select.boiler_auxheatrmode | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hphystheat | on/off hyst heat | uint16 (>=50<=1500) | K*min | True | number.boiler_on/off_hyst_heat | number.boiler_hphystheat |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hphystcool | on/off hyst cool | uint16 (>=50<=1500) | K*min | True | number.boiler_on/off_hyst_cool | number.boiler_hphystcool |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hphystpool | on/off hyst pool | uint16 (>=50<=1500) | K*min | True | number.boiler_on/off_hyst_pool | number.boiler_hphystpool |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | silentmode | silent mode | enum [off|auto|on] | True | select.boiler_silent_mode | select.boiler_silentmode | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | silentfrom | silent mode from | uint8 (>=0<=3810) | minutes | True | number.boiler_silent_mode_from | number.boiler_silentfrom |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | silentto | silent mode to | uint8 (>=0<=3810) | minutes | True | number.boiler_silent_mode_to | number.boiler_silentto |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | mintempsilent | min outside temp for silent mode | int8 (>=-126<=126) | C | True | number.boiler_min_outside_temp_for_silent_mode | number.boiler_mintempsilent |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | tempparmode | outside temp parallel mode | int8 (>=-126<=126) | C | True | number.boiler_outside_temp_parallel_mode | number.boiler_tempparmode |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxheatmix | aux heater mixing valve | int8 (>=-100<=100) | % | False | sensor.boiler_aux_heater_mixing_valve | sensor.boiler_auxheatmix |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | tempdiffheat | temp diff TC3/TC0 heat | uint8 (>=2<=10) | K | True | number.boiler_temp_diff_TC3/TC0_heat | number.boiler_tempdiffheat |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | tempdiffcool | temp diff TC3/TC0 cool | uint8 (>=2<=10) | K | True | number.boiler_temp_diff_TC3/TC0_cool | number.boiler_tempdiffcool |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | vpcooling | valve/pump cooling | boolean | True | switch.boiler_valve/pump_cooling | switch.boiler_vpcooling | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | heatcable | heating cable | boolean | True | switch.boiler_heating_cable | switch.boiler_heatcable | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | vc0valve | VC0 valve | boolean | True | switch.boiler_VC0_valve | switch.boiler_vc0valve | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | primepump | primary heatpump | boolean | True | switch.boiler_primary_heatpump | switch.boiler_primepump | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | primepumpmod | primary heatpump modulation | uint8 (>=0<=100) | % | True | number.boiler_primary_heatpump_modulation | number.boiler_primepumpmod |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hp3way | 3-way valve | boolean | True | switch.boiler_3-way_valve | switch.boiler_hp3way | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | elheatstep1 | el. heater step 1 | boolean | True | switch.boiler_el._heater_step_1 | switch.boiler_elheatstep1 | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | elheatstep2 | el. heater step 2 | boolean | True | switch.boiler_el._heater_step_2 | switch.boiler_elheatstep2 | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | elheatstep3 | el. heater step 3 | boolean | True | switch.boiler_el._heater_step_3 | switch.boiler_elheatstep3 | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpea0 | condensate reservoir heating (EA0) | boolean | False | binary_sensor.boiler_condensate_reservoir_heating_(EA0) | binary_sensor.boiler_hpea0 | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hppumpmode | primary heatpump mode | enum [auto|continuous] | True | select.boiler_primary_heatpump_mode | select.boiler_hppumpmode | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | fan | fan | uint8 (>=20<=100) | % | True | number.boiler_fan | number.boiler_fan |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | shutdown | shutdown | boolean | True | switch.boiler_shutdown | switch.boiler_shutdown | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | alternatingop | alternating operation | boolean | True | switch.boiler_dhw_alternating_operation | switch.boiler_dhw_alternatingop | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | altopprioheat | prioritise heating during dhw | uint8 (>=20<=120) | minutes | True | number.boiler_dhw_prioritise_heating_during_dhw | number.boiler_dhw_altopprioheat |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | altoppriodhw | prioritise dhw during heating | uint8 (>=30<=120) | minutes | True | number.boiler_dhw_prioritise_dhw_during_heating | number.boiler_dhw_altoppriodhw |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | comfoff | comfort switch off | uint8 (>=15<=65) | C | True | number.boiler_dhw_comfort_switch_off | number.boiler_dhw_comfoff |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | ecooff | eco switch off | uint8 (>=15<=65) | C | True | number.boiler_dhw_eco_switch_off | number.boiler_dhw_ecooff |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | ecoplusoff | eco+ switch off | uint8 (>=48<=63) | C | True | number.boiler_dhw_eco+_switch_off | number.boiler_dhw_ecoplusoff |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | comfdiff | comfort diff | uint8 (>=6<=12) | K | True | number.boiler_dhw_comfort_diff | number.boiler_dhw_comfdiff |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | ecodiff | eco diff | uint8 (>=6<=12) | K | True | number.boiler_dhw_eco_diff | number.boiler_dhw_ecodiff |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | ecoplusdiff | eco+ diff | uint8 (>=6<=12) | K | True | number.boiler_dhw_eco+_diff | number.boiler_dhw_ecoplusdiff |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | comfstop | comfort stop temp | uint8 (>=0<=254) | C | True | number.boiler_dhw_comfort_stop_temp | number.boiler_dhw_comfstop |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | ecostop | eco stop temp | uint8 (>=0<=254) | C | True | number.boiler_dhw_eco_stop_temp | number.boiler_dhw_ecostop |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | ecoplusstop | eco+ stop temp | uint8 (>=0<=254) | C | True | number.boiler_dhw_eco+_stop_temp | number.boiler_dhw_ecoplusstop |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpcircpumpdhw | circulation pump available during dhw | boolean | True | switch.boiler_dhw_circulation_pump_available_during_dhw | switch.boiler_dhw_hpcircpumpdhw | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | tapactivated | turn on/off | boolean | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | comfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | comfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | chargeoptimization | charge optimization | boolean | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | circpump | circulation pump available | boolean | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | chargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | circ | circulation active | boolean | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | activated | activated | boolean | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | onetime | one time charging | boolean | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | disinfecting | disinfecting | boolean | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | charging | charging | boolean | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | recharging | recharging | boolean | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | tempok | temperature ok | boolean | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | active | active | boolean | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | 3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | setpumppower | set pump power | uint8 (>=0<=100) | % | False | sensor.boiler_dhw_set_pump_power | sensor.boiler_dhw_setpumppower |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | starts | starts | uint24 (>=0<=16777213) | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm |
Geo 5xx | boiler | 173 | reset | reset | cmd [-|maintenance|error|history|message] | True | sensor.boiler_reset | sensor.boiler_reset | |
Geo 5xx | boiler | 173 | heatingoff | force heating off | boolean | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
Geo 5xx | boiler | 173 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
Geo 5xx | boiler | 173 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
Geo 5xx | boiler | 173 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
Geo 5xx | boiler | 173 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
Geo 5xx | boiler | 173 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
Geo 5xx | boiler | 173 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
Geo 5xx | boiler | 173 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
Geo 5xx | boiler | 173 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
Geo 5xx | boiler | 173 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
Geo 5xx | boiler | 173 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
Geo 5xx | boiler | 173 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
Geo 5xx | boiler | 173 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
Geo 5xx | boiler | 173 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
Geo 5xx | boiler | 173 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
Geo 5xx | boiler | 173 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
Geo 5xx | boiler | 173 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
Geo 5xx | boiler | 173 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
Geo 5xx | boiler | 173 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
Geo 5xx | boiler | 173 | setflowtemp | set flow temperature | uint8 (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
Geo 5xx | boiler | 173 | setburnpow | burner set power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
Geo 5xx | boiler | 173 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
Geo 5xx | boiler | 173 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
Geo 5xx | boiler | 173 | burnstarts | burner starts | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
Geo 5xx | boiler | 173 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
Geo 5xx | boiler | 173 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
Geo 5xx | boiler | 173 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
Geo 5xx | boiler | 173 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
Geo 5xx | boiler | 173 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
Geo 5xx | boiler | 173 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
Geo 5xx | boiler | 173 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
Geo 5xx | boiler | 173 | servicecodenumber | service code number | uint16 (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
Geo 5xx | boiler | 173 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
Geo 5xx | boiler | 173 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
Geo 5xx | boiler | 173 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
Geo 5xx | boiler | 173 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
Geo 5xx | boiler | 173 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
Geo 5xx | boiler | 173 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
Geo 5xx | boiler | 173 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
Geo 5xx | boiler | 173 | nrgdhw | energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_dhw_energy | sensor.boiler_dhw_nrgdhw |
Geo 5xx | boiler | 173 | nrgheat | energy heating | uint24 (>=0<=167772) | kWh | False | sensor.boiler_energy_heating | sensor.boiler_nrgheat |
Geo 5xx | boiler | 173 | metertotal | meter total | uint24 (>=0<=167772) | kWh | False | sensor.boiler_meter_total | sensor.boiler_metertotal |
Geo 5xx | boiler | 173 | metercomp | meter compressor | uint24 (>=0<=167772) | kWh | False | sensor.boiler_meter_compressor | sensor.boiler_metercomp |
Geo 5xx | boiler | 173 | metereheat | meter e-heater | uint24 (>=0<=167772) | kWh | False | sensor.boiler_meter_e-heater | sensor.boiler_metereheat |
Geo 5xx | boiler | 173 | meterheat | meter heating | uint24 (>=0<=167772) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat |
Geo 5xx | boiler | 173 | meterdhw | meter | uint24 (>=0<=167772) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meterdhw |
Geo 5xx | boiler | 173 | uptimetotal | heatpump total uptime | time (>=0<=279620) | minutes | False | sensor.boiler_heatpump_total_uptime | sensor.boiler_uptimetotal |
Geo 5xx | boiler | 173 | uptimecontrol | total operating time heat | time (>=0<=279620) | minutes | False | sensor.boiler_total_operating_time_heat | sensor.boiler_uptimecontrol |
Geo 5xx | boiler | 173 | uptimecompheating | operating time compressor heating | time (>=0<=279620) | minutes | False | sensor.boiler_operating_time_compressor_heating | sensor.boiler_uptimecompheating |
Geo 5xx | boiler | 173 | uptimecompcooling | operating time compressor cooling | time (>=0<=279620) | minutes | False | sensor.boiler_operating_time_compressor_cooling | sensor.boiler_uptimecompcooling |
Geo 5xx | boiler | 173 | uptimecompdhw | operating time compressor | time (>=0<=279620) | minutes | False | sensor.boiler_dhw_operating_time_compressor | sensor.boiler_dhw_uptimecompdhw |
Geo 5xx | boiler | 173 | uptimecomppool | operating time compressor pool | time (>=0<=279620) | minutes | False | sensor.boiler_operating_time_compressor_pool | sensor.boiler_uptimecomppool |
Geo 5xx | boiler | 173 | totalcompstarts | total compressor control starts | uint24 (>=0<=16777213) | False | sensor.boiler_total_compressor_control_starts | sensor.boiler_totalcompstarts | |
Geo 5xx | boiler | 173 | heatingstarts | heating control starts | uint24 (>=0<=16777213) | False | sensor.boiler_heating_control_starts | sensor.boiler_heatingstarts | |
Geo 5xx | boiler | 173 | coolingstarts | cooling control starts | uint24 (>=0<=16777213) | False | sensor.boiler_cooling_control_starts | sensor.boiler_coolingstarts | |
Geo 5xx | boiler | 173 | starts2 | control starts2 | uint24 (>=0<=16777213) | False | sensor.boiler_dhw_control_starts2 | sensor.boiler_dhw_starts2 | |
Geo 5xx | boiler | 173 | poolstarts | pool control starts | uint24 (>=0<=16777213) | False | sensor.boiler_pool_control_starts | sensor.boiler_poolstarts | |
Geo 5xx | boiler | 173 | nrgconstotal | total energy consumption | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_total_energy_consumption | sensor.boiler_nrgconstotal |
Geo 5xx | boiler | 173 | nrgconscomptotal | total energy consumption compressor | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_total_energy_consumption_compressor | sensor.boiler_nrgconscomptotal |
Geo 5xx | boiler | 173 | nrgconscompheating | energy consumption compressor heating | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_energy_consumption_compressor_heating | sensor.boiler_nrgconscompheating |
Geo 5xx | boiler | 173 | nrgconscompdhw | energy consumption compressor | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_dhw_energy_consumption_compressor | sensor.boiler_dhw_nrgconscompdhw |
Geo 5xx | boiler | 173 | nrgconscompcooling | energy consumption compressor cooling | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_energy_consumption_compressor_cooling | sensor.boiler_nrgconscompcooling |
Geo 5xx | boiler | 173 | nrgconscomppool | energy consumption compressor pool | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_energy_consumption_compressor_pool | sensor.boiler_nrgconscomppool |
Geo 5xx | boiler | 173 | auxelecheatnrgconstotal | total aux elec. heater energy consumption | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_total_aux_elec._heater_energy_consumption | sensor.boiler_auxelecheatnrgconstotal |
Geo 5xx | boiler | 173 | auxelecheatnrgconsheating | aux elec. heater energy consumption heating | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_aux_elec._heater_energy_consumption_heating | sensor.boiler_auxelecheatnrgconsheating |
Geo 5xx | boiler | 173 | auxelecheatnrgconsdhw | aux elec. heater energy consumption | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_dhw_aux_elec._heater_energy_consumption | sensor.boiler_dhw_auxelecheatnrgconsdhw |
Geo 5xx | boiler | 173 | auxelecheatnrgconspool | aux elec. heater energy consumption pool | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_aux_elec._heater_energy_consumption_pool | sensor.boiler_auxelecheatnrgconspool |
Geo 5xx | boiler | 173 | nrgsupptotal | total energy supplied | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_total_energy_supplied | sensor.boiler_nrgsupptotal |
Geo 5xx | boiler | 173 | nrgsuppheating | total energy supplied heating | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_total_energy_supplied_heating | sensor.boiler_nrgsuppheating |
Geo 5xx | boiler | 173 | nrgsuppdhw | total energy warm supplied | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_dhw_total_energy_warm_supplied | sensor.boiler_dhw_nrgsuppdhw |
Geo 5xx | boiler | 173 | nrgsuppcooling | total energy supplied cooling | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_total_energy_supplied_cooling | sensor.boiler_nrgsuppcooling |
Geo 5xx | boiler | 173 | nrgsupppool | total energy supplied pool | uint24 (>=0<=16777213) | kWh | False | sensor.boiler_total_energy_supplied_pool | sensor.boiler_nrgsupppool |
Geo 5xx | boiler | 173 | hppower | compressor power output | uint8 (>=0<=25) | kW | False | sensor.boiler_compressor_power_output | sensor.boiler_hppower |
Geo 5xx | boiler | 173 | hpmaxpower | compressor max power | uint8 (>=0<=100) | % | True | number.boiler_compressor_max_power | number.boiler_hpmaxpower |
Geo 5xx | boiler | 173 | hpsetdiffpress | set differental pressure | uint8 (>=150<=750) | mbar | True | number.boiler_set_differental_pressure | number.boiler_hpsetdiffpress |
Geo 5xx | boiler | 173 | hpcompon | hp compressor | boolean | False | binary_sensor.boiler_hp_compressor | binary_sensor.boiler_hpcompon | |
Geo 5xx | boiler | 173 | hpactivity | compressor activity | enum [none|heating|cooling|hot water|pool|unknown|defrost] | False | sensor.boiler_compressor_activity | sensor.boiler_hpactivity | |
Geo 5xx | boiler | 173 | hpbrinepumpspd | brine pump speed | uint8 (>=0<=100) | % | False | sensor.boiler_brine_pump_speed | sensor.boiler_hpbrinepumpspd |
Geo 5xx | boiler | 173 | hpswitchvalve | switch valve | boolean | False | binary_sensor.boiler_switch_valve | binary_sensor.boiler_hpswitchvalve | |
Geo 5xx | boiler | 173 | hpcompspd | compressor speed | uint8 (>=0<=100) | % | False | sensor.boiler_compressor_speed | sensor.boiler_hpcompspd |
Geo 5xx | boiler | 173 | hpcircspd | circulation pump speed | uint8 (>=0<=100) | % | False | sensor.boiler_circulation_pump_speed | sensor.boiler_hpcircspd |
Geo 5xx | boiler | 173 | hpbrinein | brine in/evaporator | int16 (>=-3199<=3199) | C | False | sensor.boiler_brine_in/evaporator | sensor.boiler_hpbrinein |
Geo 5xx | boiler | 173 | hpbrineout | brine out/condenser | int16 (>=-3199<=3199) | C | False | sensor.boiler_brine_out/condenser | sensor.boiler_hpbrineout |
Geo 5xx | boiler | 173 | hptc0 | heat carrier return (TC0) | int16 (>=-3199<=3199) | C | False | sensor.boiler_heat_carrier_return_(TC0) | sensor.boiler_hptc0 |
Geo 5xx | boiler | 173 | hptc1 | heat carrier forward (TC1) | int16 (>=-3199<=3199) | C | False | sensor.boiler_heat_carrier_forward_(TC1) | sensor.boiler_hptc1 |
Geo 5xx | boiler | 173 | hptc3 | condenser temperature (TC3) | int16 (>=-3199<=3199) | C | False | sensor.boiler_condenser_temperature_(TC3) | sensor.boiler_hptc3 |
Geo 5xx | boiler | 173 | hptr1 | compressor temperature (TR1) | int16 (>=-3199<=3199) | C | False | sensor.boiler_compressor_temperature_(TR1) | sensor.boiler_hptr1 |
Geo 5xx | boiler | 173 | hptr3 | refrigerant temperature liquid side (condenser output) (TR3) | int16 (>=-3199<=3199) | C | False | sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3) | sensor.boiler_hptr3 |
Geo 5xx | boiler | 173 | hptr4 | evaporator inlet temperature (TR4) | int16 (>=-3199<=3199) | C | False | sensor.boiler_evaporator_inlet_temperature_(TR4) | sensor.boiler_hptr4 |
Geo 5xx | boiler | 173 | hptr5 | compressor inlet temperature (TR5) | int16 (>=-3199<=3199) | C | False | sensor.boiler_compressor_inlet_temperature_(TR5) | sensor.boiler_hptr5 |
Geo 5xx | boiler | 173 | hptr6 | compressor outlet temperature (TR6) | int16 (>=-3199<=3199) | C | False | sensor.boiler_compressor_outlet_temperature_(TR6) | sensor.boiler_hptr6 |
Geo 5xx | boiler | 173 | hptr7 | refrigerant temperature gas side (condenser input) (TR7) | int16 (>=-3199<=3199) | C | False | sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7) | sensor.boiler_hptr7 |
Geo 5xx | boiler | 173 | hptl2 | air inlet temperature (TL2) | int16 (>=-3199<=3199) | C | False | sensor.boiler_air_inlet_temperature_(TL2) | sensor.boiler_hptl2 |
Geo 5xx | boiler | 173 | hppl1 | low pressure side temperature (PL1) | int16 (>=-3199<=3199) | C | False | sensor.boiler_low_pressure_side_temperature_(PL1) | sensor.boiler_hppl1 |
Geo 5xx | boiler | 173 | hpph1 | high pressure side temperature (PH1) | int16 (>=-3199<=3199) | C | False | sensor.boiler_high_pressure_side_temperature_(PH1) | sensor.boiler_hpph1 |
Geo 5xx | boiler | 173 | hpta4 | drain pan temp (TA4) | int16 (>=-3199<=3199) | C | False | sensor.boiler_drain_pan_temp_(TA4) | sensor.boiler_hpta4 |
Geo 5xx | boiler | 173 | hptw1 | reservoir temp (TW1) | int16 (>=-3199<=3199) | C | False | sensor.boiler_reservoir_temp_(TW1) | sensor.boiler_hptw1 |
Geo 5xx | boiler | 173 | poolsettemp | pool set temperature | uint8 (>=0<=127) | C | True | number.boiler_pool_set_temperature | number.boiler_poolsettemp |
Geo 5xx | boiler | 173 | hp4way | 4-way valve (VR4) | enum [cooling & defrost|heating & dhw] | False | sensor.boiler_4-way_valve_(VR4) | sensor.boiler_hp4way | |
Geo 5xx | boiler | 173 | hpin1opt | input 1 options | string | True | sensor.boiler_input_1_options | sensor.boiler_hpin1opt | |
Geo 5xx | boiler | 173 | hpin2opt | input 2 options | string | True | sensor.boiler_input_2_options | sensor.boiler_hpin2opt | |
Geo 5xx | boiler | 173 | hpin3opt | input 3 options | string | True | sensor.boiler_input_3_options | sensor.boiler_hpin3opt | |
Geo 5xx | boiler | 173 | hpin4opt | input 4 options | string | True | sensor.boiler_input_4_options | sensor.boiler_hpin4opt | |
Geo 5xx | boiler | 173 | maxheatcomp | heat limit compressor | enum [0 kW|2 kW|3 kW|4 kW|6 kW|9 kW] | True | select.boiler_heat_limit_compressor | select.boiler_maxheatcomp | |
Geo 5xx | boiler | 173 | maxheatheat | heat limit heating | enum [0 kW|2 kW|3 kW|4 kW|6 kW|9 kW] | True | select.boiler_heat_limit_heating | select.boiler_maxheatheat | |
Geo 5xx | boiler | 173 | maxheatdhw | heat limit | enum [0 kW|2 kW|3 kW|4 kW|6 kW|9 kW] | True | select.boiler_dhw_heat_limit | select.boiler_dhw_maxheatdhw | |
Geo 5xx | boiler | 173 | mandefrost | manual defrost | boolean | True | switch.boiler_manual_defrost | switch.boiler_mandefrost | |
Geo 5xx | boiler | 173 | pvcooling | cooling only with PV | boolean | True | switch.boiler_cooling_only_with_PV | switch.boiler_pvcooling | |
Geo 5xx | boiler | 173 | auxheateronly | aux heater only | boolean | True | switch.boiler_aux_heater_only | switch.boiler_auxheateronly | |
Geo 5xx | boiler | 173 | auxheateroff | disable aux heater | boolean | True | switch.boiler_disable_aux_heater | switch.boiler_auxheateroff | |
Geo 5xx | boiler | 173 | auxheaterstatus | aux heater status | uint8 (>=0<=100) | % | False | sensor.boiler_aux_heater_status | sensor.boiler_auxheaterstatus |
Geo 5xx | boiler | 173 | auxheaterdelay | aux heater on delay | uint16 (>=10<=1000) | K*min | True | number.boiler_aux_heater_on_delay | number.boiler_auxheaterdelay |
Geo 5xx | boiler | 173 | auxmaxlimit | aux heater max limit | uint8 (>=0<=10) | K | True | number.boiler_aux_heater_max_limit | number.boiler_auxmaxlimit |
Geo 5xx | boiler | 173 | auxlimitstart | aux heater limit start | uint8 (>=0<=10) | K | True | number.boiler_aux_heater_limit_start | number.boiler_auxlimitstart |
Geo 5xx | boiler | 173 | auxheatrmode | aux heater mode | enum [eco|comfort] | True | select.boiler_aux_heater_mode | select.boiler_auxheatrmode | |
Geo 5xx | boiler | 173 | hphystheat | on/off hyst heat | uint16 (>=50<=1500) | K*min | True | number.boiler_on/off_hyst_heat | number.boiler_hphystheat |
Geo 5xx | boiler | 173 | hphystcool | on/off hyst cool | uint16 (>=50<=1500) | K*min | True | number.boiler_on/off_hyst_cool | number.boiler_hphystcool |
Geo 5xx | boiler | 173 | hphystpool | on/off hyst pool | uint16 (>=50<=1500) | K*min | True | number.boiler_on/off_hyst_pool | number.boiler_hphystpool |
Geo 5xx | boiler | 173 | silentmode | silent mode | enum [off|auto|on] | True | select.boiler_silent_mode | select.boiler_silentmode | |
Geo 5xx | boiler | 173 | silentfrom | silent mode from | uint8 (>=0<=3810) | minutes | True | number.boiler_silent_mode_from | number.boiler_silentfrom |
Geo 5xx | boiler | 173 | silentto | silent mode to | uint8 (>=0<=3810) | minutes | True | number.boiler_silent_mode_to | number.boiler_silentto |
Geo 5xx | boiler | 173 | mintempsilent | min outside temp for silent mode | int8 (>=-126<=126) | C | True | number.boiler_min_outside_temp_for_silent_mode | number.boiler_mintempsilent |
Geo 5xx | boiler | 173 | tempparmode | outside temp parallel mode | int8 (>=-126<=126) | C | True | number.boiler_outside_temp_parallel_mode | number.boiler_tempparmode |
Geo 5xx | boiler | 173 | auxheatmix | aux heater mixing valve | int8 (>=-100<=100) | % | False | sensor.boiler_aux_heater_mixing_valve | sensor.boiler_auxheatmix |
Geo 5xx | boiler | 173 | tempdiffheat | temp diff TC3/TC0 heat | uint8 (>=2<=10) | K | True | number.boiler_temp_diff_TC3/TC0_heat | number.boiler_tempdiffheat |
Geo 5xx | boiler | 173 | tempdiffcool | temp diff TC3/TC0 cool | uint8 (>=2<=10) | K | True | number.boiler_temp_diff_TC3/TC0_cool | number.boiler_tempdiffcool |
Geo 5xx | boiler | 173 | vpcooling | valve/pump cooling | boolean | True | switch.boiler_valve/pump_cooling | switch.boiler_vpcooling | |
Geo 5xx | boiler | 173 | heatcable | heating cable | boolean | True | switch.boiler_heating_cable | switch.boiler_heatcable | |
Geo 5xx | boiler | 173 | vc0valve | VC0 valve | boolean | True | switch.boiler_VC0_valve | switch.boiler_vc0valve | |
Geo 5xx | boiler | 173 | primepump | primary heatpump | boolean | True | switch.boiler_primary_heatpump | switch.boiler_primepump | |
Geo 5xx | boiler | 173 | primepumpmod | primary heatpump modulation | uint8 (>=0<=100) | % | True | number.boiler_primary_heatpump_modulation | number.boiler_primepumpmod |
Geo 5xx | boiler | 173 | hp3way | 3-way valve | boolean | True | switch.boiler_3-way_valve | switch.boiler_hp3way | |
Geo 5xx | boiler | 173 | elheatstep1 | el. heater step 1 | boolean | True | switch.boiler_el._heater_step_1 | switch.boiler_elheatstep1 | |
Geo 5xx | boiler | 173 | elheatstep2 | el. heater step 2 | boolean | True | switch.boiler_el._heater_step_2 | switch.boiler_elheatstep2 | |
Geo 5xx | boiler | 173 | elheatstep3 | el. heater step 3 | boolean | True | switch.boiler_el._heater_step_3 | switch.boiler_elheatstep3 | |
Geo 5xx | boiler | 173 | hpea0 | condensate reservoir heating (EA0) | boolean | False | binary_sensor.boiler_condensate_reservoir_heating_(EA0) | binary_sensor.boiler_hpea0 | |
Geo 5xx | boiler | 173 | hppumpmode | primary heatpump mode | enum [auto|continuous] | True | select.boiler_primary_heatpump_mode | select.boiler_hppumpmode | |
Geo 5xx | boiler | 173 | fan | fan | uint8 (>=20<=100) | % | True | number.boiler_fan | number.boiler_fan |
Geo 5xx | boiler | 173 | shutdown | shutdown | boolean | True | switch.boiler_shutdown | switch.boiler_shutdown | |
Geo 5xx | boiler | 173 | alternatingop | alternating operation | boolean | True | switch.boiler_dhw_alternating_operation | switch.boiler_dhw_alternatingop | |
Geo 5xx | boiler | 173 | altopprioheat | prioritise heating during dhw | uint8 (>=20<=120) | minutes | True | number.boiler_dhw_prioritise_heating_during_dhw | number.boiler_dhw_altopprioheat |
Geo 5xx | boiler | 173 | altoppriodhw | prioritise dhw during heating | uint8 (>=30<=120) | minutes | True | number.boiler_dhw_prioritise_dhw_during_heating | number.boiler_dhw_altoppriodhw |
Geo 5xx | boiler | 173 | comfoff | comfort switch off | uint8 (>=15<=65) | C | True | number.boiler_dhw_comfort_switch_off | number.boiler_dhw_comfoff |
Geo 5xx | boiler | 173 | ecooff | eco switch off | uint8 (>=15<=65) | C | True | number.boiler_dhw_eco_switch_off | number.boiler_dhw_ecooff |
Geo 5xx | boiler | 173 | ecoplusoff | eco+ switch off | uint8 (>=48<=63) | C | True | number.boiler_dhw_eco+_switch_off | number.boiler_dhw_ecoplusoff |
Geo 5xx | boiler | 173 | comfdiff | comfort diff | uint8 (>=6<=12) | K | True | number.boiler_dhw_comfort_diff | number.boiler_dhw_comfdiff |
Geo 5xx | boiler | 173 | ecodiff | eco diff | uint8 (>=6<=12) | K | True | number.boiler_dhw_eco_diff | number.boiler_dhw_ecodiff |
Geo 5xx | boiler | 173 | ecoplusdiff | eco+ diff | uint8 (>=6<=12) | K | True | number.boiler_dhw_eco+_diff | number.boiler_dhw_ecoplusdiff |
Geo 5xx | boiler | 173 | comfstop | comfort stop temp | uint8 (>=0<=254) | C | True | number.boiler_dhw_comfort_stop_temp | number.boiler_dhw_comfstop |
Geo 5xx | boiler | 173 | ecostop | eco stop temp | uint8 (>=0<=254) | C | True | number.boiler_dhw_eco_stop_temp | number.boiler_dhw_ecostop |
Geo 5xx | boiler | 173 | ecoplusstop | eco+ stop temp | uint8 (>=0<=254) | C | True | number.boiler_dhw_eco+_stop_temp | number.boiler_dhw_ecoplusstop |
Geo 5xx | boiler | 173 | hpcircpumpdhw | circulation pump available during dhw | boolean | True | switch.boiler_dhw_circulation_pump_available_during_dhw | switch.boiler_dhw_hpcircpumpdhw | |
Geo 5xx | boiler | 173 | tapactivated | turn on/off | boolean | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | |
Geo 5xx | boiler | 173 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp |
Geo 5xx | boiler | 173 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp |
Geo 5xx | boiler | 173 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow |
Geo 5xx | boiler | 173 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus |
Geo 5xx | boiler | 173 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff |
Geo 5xx | boiler | 173 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle |
Geo 5xx | boiler | 173 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp |
Geo 5xx | boiler | 173 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | |
Geo 5xx | boiler | 173 | comfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | |
Geo 5xx | boiler | 173 | comfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | |
Geo 5xx | boiler | 173 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset |
Geo 5xx | boiler | 173 | chargeoptimization | charge optimization | boolean | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | |
Geo 5xx | boiler | 173 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower |
Geo 5xx | boiler | 173 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp |
Geo 5xx | boiler | 173 | circpump | circulation pump available | boolean | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | |
Geo 5xx | boiler | 173 | chargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | |
Geo 5xx | boiler | 173 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston |
Geo 5xx | boiler | 173 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff |
Geo 5xx | boiler | 173 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp |
Geo 5xx | boiler | 173 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | |
Geo 5xx | boiler | 173 | circ | circulation active | boolean | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | |
Geo 5xx | boiler | 173 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp |
Geo 5xx | boiler | 173 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 |
Geo 5xx | boiler | 173 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow |
Geo 5xx | boiler | 173 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 |
Geo 5xx | boiler | 173 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 |
Geo 5xx | boiler | 173 | activated | activated | boolean | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | |
Geo 5xx | boiler | 173 | onetime | one time charging | boolean | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | |
Geo 5xx | boiler | 173 | disinfecting | disinfecting | boolean | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | |
Geo 5xx | boiler | 173 | charging | charging | boolean | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | |
Geo 5xx | boiler | 173 | recharging | recharging | boolean | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | |
Geo 5xx | boiler | 173 | tempok | temperature ok | boolean | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | |
Geo 5xx | boiler | 173 | active | active | boolean | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | |
Geo 5xx | boiler | 173 | 3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | |
Geo 5xx | boiler | 173 | setpumppower | set pump power | uint8 (>=0<=100) | % | False | sensor.boiler_dhw_set_pump_power | sensor.boiler_dhw_setpumppower |
Geo 5xx | boiler | 173 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp |
Geo 5xx | boiler | 173 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp |
Geo 5xx | boiler | 173 | starts | starts | uint24 (>=0<=16777213) | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | |
Geo 5xx | boiler | 173 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | reset | reset | cmd [-|maintenance|error|history|message] | True | sensor.boiler_reset | sensor.boiler_reset | |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | heatingoff | force heating off | boolean | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | burngas | gas | boolean | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | burngas2 | gas stage 2 | boolean | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | fanwork | fan | boolean | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | ignwork | ignition | boolean | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | oilpreheat | oil preheating | boolean | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | curveon | heatingcurve on | boolean | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | summertemp | summer temperature | uint8 (>=0<=30) | C | True | number.boiler_summer_temperature | number.boiler_summertemp |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | nofrostmode | nofrost mode | boolean | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | setflowtemp | set flow temperature | uint8 (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | setburnpow | burner set power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | burnstarts | burner starts | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | servicecodenumber | service code number | uint16 (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | meterdhw | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meterdhw |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | gasmeterdhw | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeterdhw |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | nrgdhw2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrgdhw2 |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | tapactivated | turn on/off | boolean | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | comfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | comfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | chargeoptimization | charge optimization | boolean | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | circpump | circulation pump available | boolean | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | chargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | circ | circulation active | boolean | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | activated | activated | boolean | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | onetime | one time charging | boolean | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | disinfecting | disinfecting | boolean | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | charging | charging | boolean | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | recharging | recharging | boolean | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | tempok | temperature ok | boolean | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | active | active | boolean | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | 3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | setpumppower | set pump power | uint8 (>=0<=100) | % | False | sensor.boiler_dhw_set_pump_power | sensor.boiler_dhw_setpumppower |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | starts | starts | uint24 (>=0<=16777213) | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat |
Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | nrgdhw | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrgdhw |
Logamax U122/Cerapur | boiler | 203 | reset | reset | cmd [-|maintenance|error|history|message] | True | sensor.boiler_reset | sensor.boiler_reset | |
Logamax U122/Cerapur | boiler | 203 | heatingoff | force heating off | boolean | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
Logamax U122/Cerapur | boiler | 203 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
Logamax U122/Cerapur | boiler | 203 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
Logamax U122/Cerapur | boiler | 203 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
Logamax U122/Cerapur | boiler | 203 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
Logamax U122/Cerapur | boiler | 203 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
Logamax U122/Cerapur | boiler | 203 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
Logamax U122/Cerapur | boiler | 203 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
Logamax U122/Cerapur | boiler | 203 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
Logamax U122/Cerapur | boiler | 203 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
Logamax U122/Cerapur | boiler | 203 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
Logamax U122/Cerapur | boiler | 203 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
Logamax U122/Cerapur | boiler | 203 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
Logamax U122/Cerapur | boiler | 203 | burngas | gas | boolean | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
Logamax U122/Cerapur | boiler | 203 | burngas2 | gas stage 2 | boolean | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
Logamax U122/Cerapur | boiler | 203 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr |
Logamax U122/Cerapur | boiler | 203 | fanwork | fan | boolean | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
Logamax U122/Cerapur | boiler | 203 | ignwork | ignition | boolean | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
Logamax U122/Cerapur | boiler | 203 | oilpreheat | oil preheating | boolean | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
Logamax U122/Cerapur | boiler | 203 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower |
Logamax U122/Cerapur | boiler | 203 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower |
Logamax U122/Cerapur | boiler | 203 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod |
Logamax U122/Cerapur | boiler | 203 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
Logamax U122/Cerapur | boiler | 203 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock |
Logamax U122/Cerapur | boiler | 203 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
Logamax U122/Cerapur | boiler | 203 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
Logamax U122/Cerapur | boiler | 203 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
Logamax U122/Cerapur | boiler | 203 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
Logamax U122/Cerapur | boiler | 203 | curveon | heatingcurve on | boolean | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | |
Logamax U122/Cerapur | boiler | 203 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase |
Logamax U122/Cerapur | boiler | 203 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend |
Logamax U122/Cerapur | boiler | 203 | summertemp | summer temperature | uint8 (>=0<=30) | C | True | number.boiler_summer_temperature | number.boiler_summertemp |
Logamax U122/Cerapur | boiler | 203 | nofrostmode | nofrost mode | boolean | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | |
Logamax U122/Cerapur | boiler | 203 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp |
Logamax U122/Cerapur | boiler | 203 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
Logamax U122/Cerapur | boiler | 203 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
Logamax U122/Cerapur | boiler | 203 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
Logamax U122/Cerapur | boiler | 203 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
Logamax U122/Cerapur | boiler | 203 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
Logamax U122/Cerapur | boiler | 203 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
Logamax U122/Cerapur | boiler | 203 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
Logamax U122/Cerapur | boiler | 203 | setflowtemp | set flow temperature | uint8 (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
Logamax U122/Cerapur | boiler | 203 | setburnpow | burner set power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
Logamax U122/Cerapur | boiler | 203 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
Logamax U122/Cerapur | boiler | 203 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
Logamax U122/Cerapur | boiler | 203 | burnstarts | burner starts | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
Logamax U122/Cerapur | boiler | 203 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
Logamax U122/Cerapur | boiler | 203 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
Logamax U122/Cerapur | boiler | 203 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
Logamax U122/Cerapur | boiler | 203 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
Logamax U122/Cerapur | boiler | 203 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
Logamax U122/Cerapur | boiler | 203 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
Logamax U122/Cerapur | boiler | 203 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
Logamax U122/Cerapur | boiler | 203 | servicecodenumber | service code number | uint16 (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
Logamax U122/Cerapur | boiler | 203 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
Logamax U122/Cerapur | boiler | 203 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
Logamax U122/Cerapur | boiler | 203 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
Logamax U122/Cerapur | boiler | 203 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
Logamax U122/Cerapur | boiler | 203 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
Logamax U122/Cerapur | boiler | 203 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
Logamax U122/Cerapur | boiler | 203 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat |
Logamax U122/Cerapur | boiler | 203 | meterdhw | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meterdhw |
Logamax U122/Cerapur | boiler | 203 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat |
Logamax U122/Cerapur | boiler | 203 | gasmeterdhw | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeterdhw |
Logamax U122/Cerapur | boiler | 203 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 |
Logamax U122/Cerapur | boiler | 203 | nrgdhw2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrgdhw2 |
Logamax U122/Cerapur | boiler | 203 | tapactivated | turn on/off | boolean | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | |
Logamax U122/Cerapur | boiler | 203 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp |
Logamax U122/Cerapur | boiler | 203 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp |
Logamax U122/Cerapur | boiler | 203 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow |
Logamax U122/Cerapur | boiler | 203 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus |
Logamax U122/Cerapur | boiler | 203 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff |
Logamax U122/Cerapur | boiler | 203 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle |
Logamax U122/Cerapur | boiler | 203 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp |
Logamax U122/Cerapur | boiler | 203 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | |
Logamax U122/Cerapur | boiler | 203 | comfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | |
Logamax U122/Cerapur | boiler | 203 | comfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | |
Logamax U122/Cerapur | boiler | 203 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset |
Logamax U122/Cerapur | boiler | 203 | chargeoptimization | charge optimization | boolean | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | |
Logamax U122/Cerapur | boiler | 203 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower |
Logamax U122/Cerapur | boiler | 203 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp |
Logamax U122/Cerapur | boiler | 203 | circpump | circulation pump available | boolean | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | |
Logamax U122/Cerapur | boiler | 203 | chargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | |
Logamax U122/Cerapur | boiler | 203 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston |
Logamax U122/Cerapur | boiler | 203 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff |
Logamax U122/Cerapur | boiler | 203 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp |
Logamax U122/Cerapur | boiler | 203 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | |
Logamax U122/Cerapur | boiler | 203 | circ | circulation active | boolean | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | |
Logamax U122/Cerapur | boiler | 203 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp |
Logamax U122/Cerapur | boiler | 203 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 |
Logamax U122/Cerapur | boiler | 203 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow |
Logamax U122/Cerapur | boiler | 203 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 |
Logamax U122/Cerapur | boiler | 203 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 |
Logamax U122/Cerapur | boiler | 203 | activated | activated | boolean | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | |
Logamax U122/Cerapur | boiler | 203 | onetime | one time charging | boolean | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | |
Logamax U122/Cerapur | boiler | 203 | disinfecting | disinfecting | boolean | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | |
Logamax U122/Cerapur | boiler | 203 | charging | charging | boolean | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | |
Logamax U122/Cerapur | boiler | 203 | recharging | recharging | boolean | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | |
Logamax U122/Cerapur | boiler | 203 | tempok | temperature ok | boolean | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | |
Logamax U122/Cerapur | boiler | 203 | active | active | boolean | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | |
Logamax U122/Cerapur | boiler | 203 | 3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | |
Logamax U122/Cerapur | boiler | 203 | setpumppower | set pump power | uint8 (>=0<=100) | % | False | sensor.boiler_dhw_set_pump_power | sensor.boiler_dhw_setpumppower |
Logamax U122/Cerapur | boiler | 203 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp |
Logamax U122/Cerapur | boiler | 203 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp |
Logamax U122/Cerapur | boiler | 203 | starts | starts | uint24 (>=0<=16777213) | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | |
Logamax U122/Cerapur | boiler | 203 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm |
Logamax U122/Cerapur | boiler | 203 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower |
Logamax U122/Cerapur | boiler | 203 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
Logamax U122/Cerapur | boiler | 203 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat |
Logamax U122/Cerapur | boiler | 203 | nrgdhw | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrgdhw |
Ecomline Excellent | boiler | 206 | reset | reset | cmd [-|maintenance|error|history|message] | True | sensor.boiler_reset | sensor.boiler_reset | |
Ecomline Excellent | boiler | 206 | heatingoff | force heating off | boolean | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
Ecomline Excellent | boiler | 206 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
Ecomline Excellent | boiler | 206 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
Ecomline Excellent | boiler | 206 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
Ecomline Excellent | boiler | 206 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
Ecomline Excellent | boiler | 206 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
Ecomline Excellent | boiler | 206 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
Ecomline Excellent | boiler | 206 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
Ecomline Excellent | boiler | 206 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
Ecomline Excellent | boiler | 206 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
Ecomline Excellent | boiler | 206 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
Ecomline Excellent | boiler | 206 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
Ecomline Excellent | boiler | 206 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
Ecomline Excellent | boiler | 206 | burngas | gas | boolean | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
Ecomline Excellent | boiler | 206 | burngas2 | gas stage 2 | boolean | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
Ecomline Excellent | boiler | 206 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr |
Ecomline Excellent | boiler | 206 | fanwork | fan | boolean | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
Ecomline Excellent | boiler | 206 | ignwork | ignition | boolean | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
Ecomline Excellent | boiler | 206 | oilpreheat | oil preheating | boolean | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
Ecomline Excellent | boiler | 206 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower |
Ecomline Excellent | boiler | 206 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower |
Ecomline Excellent | boiler | 206 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod |
Ecomline Excellent | boiler | 206 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
Ecomline Excellent | boiler | 206 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock |
Ecomline Excellent | boiler | 206 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
Ecomline Excellent | boiler | 206 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
Ecomline Excellent | boiler | 206 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
Ecomline Excellent | boiler | 206 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
Ecomline Excellent | boiler | 206 | curveon | heatingcurve on | boolean | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | |
Ecomline Excellent | boiler | 206 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase |
Ecomline Excellent | boiler | 206 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend |
Ecomline Excellent | boiler | 206 | summertemp | summer temperature | uint8 (>=0<=30) | C | True | number.boiler_summer_temperature | number.boiler_summertemp |
Ecomline Excellent | boiler | 206 | nofrostmode | nofrost mode | boolean | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | |
Ecomline Excellent | boiler | 206 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp |
Ecomline Excellent | boiler | 206 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
Ecomline Excellent | boiler | 206 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
Ecomline Excellent | boiler | 206 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
Ecomline Excellent | boiler | 206 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
Ecomline Excellent | boiler | 206 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
Ecomline Excellent | boiler | 206 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
Ecomline Excellent | boiler | 206 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
Ecomline Excellent | boiler | 206 | setflowtemp | set flow temperature | uint8 (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
Ecomline Excellent | boiler | 206 | setburnpow | burner set power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
Ecomline Excellent | boiler | 206 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
Ecomline Excellent | boiler | 206 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
Ecomline Excellent | boiler | 206 | burnstarts | burner starts | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
Ecomline Excellent | boiler | 206 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
Ecomline Excellent | boiler | 206 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
Ecomline Excellent | boiler | 206 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
Ecomline Excellent | boiler | 206 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
Ecomline Excellent | boiler | 206 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
Ecomline Excellent | boiler | 206 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
Ecomline Excellent | boiler | 206 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
Ecomline Excellent | boiler | 206 | servicecodenumber | service code number | uint16 (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
Ecomline Excellent | boiler | 206 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
Ecomline Excellent | boiler | 206 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
Ecomline Excellent | boiler | 206 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
Ecomline Excellent | boiler | 206 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
Ecomline Excellent | boiler | 206 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
Ecomline Excellent | boiler | 206 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
Ecomline Excellent | boiler | 206 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat |
Ecomline Excellent | boiler | 206 | meterdhw | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meterdhw |
Ecomline Excellent | boiler | 206 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat |
Ecomline Excellent | boiler | 206 | gasmeterdhw | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeterdhw |
Ecomline Excellent | boiler | 206 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 |
Ecomline Excellent | boiler | 206 | nrgdhw2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrgdhw2 |
Ecomline Excellent | boiler | 206 | tapactivated | turn on/off | boolean | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | |
Ecomline Excellent | boiler | 206 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp |
Ecomline Excellent | boiler | 206 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp |
Ecomline Excellent | boiler | 206 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow |
Ecomline Excellent | boiler | 206 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus |
Ecomline Excellent | boiler | 206 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff |
Ecomline Excellent | boiler | 206 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle |
Ecomline Excellent | boiler | 206 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp |
Ecomline Excellent | boiler | 206 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | |
Ecomline Excellent | boiler | 206 | comfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | |
Ecomline Excellent | boiler | 206 | comfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | |
Ecomline Excellent | boiler | 206 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset |
Ecomline Excellent | boiler | 206 | chargeoptimization | charge optimization | boolean | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | |
Ecomline Excellent | boiler | 206 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower |
Ecomline Excellent | boiler | 206 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp |
Ecomline Excellent | boiler | 206 | circpump | circulation pump available | boolean | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | |
Ecomline Excellent | boiler | 206 | chargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | |
Ecomline Excellent | boiler | 206 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston |
Ecomline Excellent | boiler | 206 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff |
Ecomline Excellent | boiler | 206 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp |
Ecomline Excellent | boiler | 206 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | |
Ecomline Excellent | boiler | 206 | circ | circulation active | boolean | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | |
Ecomline Excellent | boiler | 206 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp |
Ecomline Excellent | boiler | 206 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 |
Ecomline Excellent | boiler | 206 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow |
Ecomline Excellent | boiler | 206 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 |
Ecomline Excellent | boiler | 206 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 |
Ecomline Excellent | boiler | 206 | activated | activated | boolean | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | |
Ecomline Excellent | boiler | 206 | onetime | one time charging | boolean | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | |
Ecomline Excellent | boiler | 206 | disinfecting | disinfecting | boolean | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | |
Ecomline Excellent | boiler | 206 | charging | charging | boolean | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | |
Ecomline Excellent | boiler | 206 | recharging | recharging | boolean | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | |
Ecomline Excellent | boiler | 206 | tempok | temperature ok | boolean | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | |
Ecomline Excellent | boiler | 206 | active | active | boolean | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | |
Ecomline Excellent | boiler | 206 | 3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | |
Ecomline Excellent | boiler | 206 | setpumppower | set pump power | uint8 (>=0<=100) | % | False | sensor.boiler_dhw_set_pump_power | sensor.boiler_dhw_setpumppower |
Ecomline Excellent | boiler | 206 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp |
Ecomline Excellent | boiler | 206 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp |
Ecomline Excellent | boiler | 206 | starts | starts | uint24 (>=0<=16777213) | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | |
Ecomline Excellent | boiler | 206 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm |
Ecomline Excellent | boiler | 206 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower |
Ecomline Excellent | boiler | 206 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
Ecomline Excellent | boiler | 206 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat |
Ecomline Excellent | boiler | 206 | nrgdhw | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrgdhw |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | reset | reset | cmd [-|maintenance|error|history|message] | True | sensor.boiler_reset | sensor.boiler_reset | |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | heatingoff | force heating off | boolean | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | burngas | gas | boolean | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | burngas2 | gas stage 2 | boolean | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | fanwork | fan | boolean | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | ignwork | ignition | boolean | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | oilpreheat | oil preheating | boolean | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | curveon | heatingcurve on | boolean | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | summertemp | summer temperature | uint8 (>=0<=30) | C | True | number.boiler_summer_temperature | number.boiler_summertemp |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | nofrostmode | nofrost mode | boolean | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | setflowtemp | set flow temperature | uint8 (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | setburnpow | burner set power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | burnstarts | burner starts | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | servicecodenumber | service code number | uint16 (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | meterdhw | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meterdhw |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | gasmeterdhw | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeterdhw |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | nrgdhw2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrgdhw2 |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | tapactivated | turn on/off | boolean | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | comfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | comfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | chargeoptimization | charge optimization | boolean | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | circpump | circulation pump available | boolean | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | chargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | circ | circulation active | boolean | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | activated | activated | boolean | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | onetime | one time charging | boolean | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | disinfecting | disinfecting | boolean | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | charging | charging | boolean | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | recharging | recharging | boolean | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | tempok | temperature ok | boolean | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | active | active | boolean | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | 3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | setpumppower | set pump power | uint8 (>=0<=100) | % | False | sensor.boiler_dhw_set_pump_power | sensor.boiler_dhw_setpumppower |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | starts | starts | uint24 (>=0<=16777213) | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat |
Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | nrgdhw | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrgdhw |
Cascade MC400 | boiler | 210 | reset | reset | cmd [-|maintenance|error|history|message] | True | sensor.boiler_reset | sensor.boiler_reset | |
Cascade MC400 | boiler | 210 | heatingoff | force heating off | boolean | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
Cascade MC400 | boiler | 210 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
Cascade MC400 | boiler | 210 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
Cascade MC400 | boiler | 210 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
Cascade MC400 | boiler | 210 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
Cascade MC400 | boiler | 210 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
Cascade MC400 | boiler | 210 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
Cascade MC400 | boiler | 210 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
Cascade MC400 | boiler | 210 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
Cascade MC400 | boiler | 210 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
Cascade MC400 | boiler | 210 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
Cascade MC400 | boiler | 210 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
Cascade MC400 | boiler | 210 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
Cascade MC400 | boiler | 210 | burngas | gas | boolean | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
Cascade MC400 | boiler | 210 | burngas2 | gas stage 2 | boolean | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
Cascade MC400 | boiler | 210 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr |
Cascade MC400 | boiler | 210 | fanwork | fan | boolean | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
Cascade MC400 | boiler | 210 | ignwork | ignition | boolean | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
Cascade MC400 | boiler | 210 | oilpreheat | oil preheating | boolean | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
Cascade MC400 | boiler | 210 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower |
Cascade MC400 | boiler | 210 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower |
Cascade MC400 | boiler | 210 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod |
Cascade MC400 | boiler | 210 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
Cascade MC400 | boiler | 210 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock |
Cascade MC400 | boiler | 210 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
Cascade MC400 | boiler | 210 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
Cascade MC400 | boiler | 210 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
Cascade MC400 | boiler | 210 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
Cascade MC400 | boiler | 210 | curveon | heatingcurve on | boolean | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | |
Cascade MC400 | boiler | 210 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase |
Cascade MC400 | boiler | 210 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend |
Cascade MC400 | boiler | 210 | summertemp | summer temperature | uint8 (>=0<=30) | C | True | number.boiler_summer_temperature | number.boiler_summertemp |
Cascade MC400 | boiler | 210 | nofrostmode | nofrost mode | boolean | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | |
Cascade MC400 | boiler | 210 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp |
Cascade MC400 | boiler | 210 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
Cascade MC400 | boiler | 210 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
Cascade MC400 | boiler | 210 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
Cascade MC400 | boiler | 210 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
Cascade MC400 | boiler | 210 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
Cascade MC400 | boiler | 210 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
Cascade MC400 | boiler | 210 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
Cascade MC400 | boiler | 210 | setflowtemp | set flow temperature | uint8 (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
Cascade MC400 | boiler | 210 | setburnpow | burner set power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
Cascade MC400 | boiler | 210 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
Cascade MC400 | boiler | 210 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
Cascade MC400 | boiler | 210 | burnstarts | burner starts | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
Cascade MC400 | boiler | 210 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
Cascade MC400 | boiler | 210 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
Cascade MC400 | boiler | 210 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
Cascade MC400 | boiler | 210 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
Cascade MC400 | boiler | 210 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
Cascade MC400 | boiler | 210 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
Cascade MC400 | boiler | 210 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
Cascade MC400 | boiler | 210 | servicecodenumber | service code number | uint16 (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
Cascade MC400 | boiler | 210 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
Cascade MC400 | boiler | 210 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
Cascade MC400 | boiler | 210 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
Cascade MC400 | boiler | 210 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
Cascade MC400 | boiler | 210 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
Cascade MC400 | boiler | 210 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
Cascade MC400 | boiler | 210 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat |
Cascade MC400 | boiler | 210 | meterdhw | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meterdhw |
Cascade MC400 | boiler | 210 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat |
Cascade MC400 | boiler | 210 | gasmeterdhw | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeterdhw |
Cascade MC400 | boiler | 210 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 |
Cascade MC400 | boiler | 210 | nrgdhw2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrgdhw2 |
Cascade MC400 | boiler | 210 | tapactivated | turn on/off | boolean | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | |
Cascade MC400 | boiler | 210 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp |
Cascade MC400 | boiler | 210 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp |
Cascade MC400 | boiler | 210 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow |
Cascade MC400 | boiler | 210 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus |
Cascade MC400 | boiler | 210 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff |
Cascade MC400 | boiler | 210 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle |
Cascade MC400 | boiler | 210 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp |
Cascade MC400 | boiler | 210 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | |
Cascade MC400 | boiler | 210 | comfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | |
Cascade MC400 | boiler | 210 | comfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | |
Cascade MC400 | boiler | 210 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset |
Cascade MC400 | boiler | 210 | chargeoptimization | charge optimization | boolean | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | |
Cascade MC400 | boiler | 210 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower |
Cascade MC400 | boiler | 210 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp |
Cascade MC400 | boiler | 210 | circpump | circulation pump available | boolean | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | |
Cascade MC400 | boiler | 210 | chargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | |
Cascade MC400 | boiler | 210 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston |
Cascade MC400 | boiler | 210 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff |
Cascade MC400 | boiler | 210 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp |
Cascade MC400 | boiler | 210 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | |
Cascade MC400 | boiler | 210 | circ | circulation active | boolean | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | |
Cascade MC400 | boiler | 210 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp |
Cascade MC400 | boiler | 210 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 |
Cascade MC400 | boiler | 210 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow |
Cascade MC400 | boiler | 210 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 |
Cascade MC400 | boiler | 210 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 |
Cascade MC400 | boiler | 210 | activated | activated | boolean | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | |
Cascade MC400 | boiler | 210 | onetime | one time charging | boolean | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | |
Cascade MC400 | boiler | 210 | disinfecting | disinfecting | boolean | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | |
Cascade MC400 | boiler | 210 | charging | charging | boolean | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | |
Cascade MC400 | boiler | 210 | recharging | recharging | boolean | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | |
Cascade MC400 | boiler | 210 | tempok | temperature ok | boolean | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | |
Cascade MC400 | boiler | 210 | active | active | boolean | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | |
Cascade MC400 | boiler | 210 | 3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | |
Cascade MC400 | boiler | 210 | setpumppower | set pump power | uint8 (>=0<=100) | % | False | sensor.boiler_dhw_set_pump_power | sensor.boiler_dhw_setpumppower |
Cascade MC400 | boiler | 210 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp |
Cascade MC400 | boiler | 210 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp |
Cascade MC400 | boiler | 210 | starts | starts | uint24 (>=0<=16777213) | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | |
Cascade MC400 | boiler | 210 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm |
Cascade MC400 | boiler | 210 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower |
Cascade MC400 | boiler | 210 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
Cascade MC400 | boiler | 210 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat |
Cascade MC400 | boiler | 210 | nrgdhw | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrgdhw |
EasyControl Adapter | boiler | 211 | reset | reset | cmd [-|maintenance|error|history|message] | True | sensor.boiler_reset | sensor.boiler_reset | |
EasyControl Adapter | boiler | 211 | heatingoff | force heating off | boolean | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
EasyControl Adapter | boiler | 211 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
EasyControl Adapter | boiler | 211 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
EasyControl Adapter | boiler | 211 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
EasyControl Adapter | boiler | 211 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
EasyControl Adapter | boiler | 211 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
EasyControl Adapter | boiler | 211 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
EasyControl Adapter | boiler | 211 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
EasyControl Adapter | boiler | 211 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
EasyControl Adapter | boiler | 211 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
EasyControl Adapter | boiler | 211 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
EasyControl Adapter | boiler | 211 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
EasyControl Adapter | boiler | 211 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
EasyControl Adapter | boiler | 211 | burngas | gas | boolean | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
EasyControl Adapter | boiler | 211 | burngas2 | gas stage 2 | boolean | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
EasyControl Adapter | boiler | 211 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr |
EasyControl Adapter | boiler | 211 | fanwork | fan | boolean | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
EasyControl Adapter | boiler | 211 | ignwork | ignition | boolean | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
EasyControl Adapter | boiler | 211 | oilpreheat | oil preheating | boolean | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
EasyControl Adapter | boiler | 211 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower |
EasyControl Adapter | boiler | 211 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower |
EasyControl Adapter | boiler | 211 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod |
EasyControl Adapter | boiler | 211 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
EasyControl Adapter | boiler | 211 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock |
EasyControl Adapter | boiler | 211 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
EasyControl Adapter | boiler | 211 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
EasyControl Adapter | boiler | 211 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
EasyControl Adapter | boiler | 211 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
EasyControl Adapter | boiler | 211 | curveon | heatingcurve on | boolean | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | |
EasyControl Adapter | boiler | 211 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase |
EasyControl Adapter | boiler | 211 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend |
EasyControl Adapter | boiler | 211 | summertemp | summer temperature | uint8 (>=0<=30) | C | True | number.boiler_summer_temperature | number.boiler_summertemp |
EasyControl Adapter | boiler | 211 | nofrostmode | nofrost mode | boolean | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | |
EasyControl Adapter | boiler | 211 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp |
EasyControl Adapter | boiler | 211 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
EasyControl Adapter | boiler | 211 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
EasyControl Adapter | boiler | 211 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
EasyControl Adapter | boiler | 211 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
EasyControl Adapter | boiler | 211 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
EasyControl Adapter | boiler | 211 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
EasyControl Adapter | boiler | 211 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
EasyControl Adapter | boiler | 211 | setflowtemp | set flow temperature | uint8 (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
EasyControl Adapter | boiler | 211 | setburnpow | burner set power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
EasyControl Adapter | boiler | 211 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
EasyControl Adapter | boiler | 211 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
EasyControl Adapter | boiler | 211 | burnstarts | burner starts | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
EasyControl Adapter | boiler | 211 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
EasyControl Adapter | boiler | 211 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
EasyControl Adapter | boiler | 211 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
EasyControl Adapter | boiler | 211 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
EasyControl Adapter | boiler | 211 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
EasyControl Adapter | boiler | 211 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
EasyControl Adapter | boiler | 211 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
EasyControl Adapter | boiler | 211 | servicecodenumber | service code number | uint16 (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
EasyControl Adapter | boiler | 211 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
EasyControl Adapter | boiler | 211 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
EasyControl Adapter | boiler | 211 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
EasyControl Adapter | boiler | 211 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
EasyControl Adapter | boiler | 211 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
EasyControl Adapter | boiler | 211 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
EasyControl Adapter | boiler | 211 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat |
EasyControl Adapter | boiler | 211 | meterdhw | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meterdhw |
EasyControl Adapter | boiler | 211 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat |
EasyControl Adapter | boiler | 211 | gasmeterdhw | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeterdhw |
EasyControl Adapter | boiler | 211 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 |
EasyControl Adapter | boiler | 211 | nrgdhw2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrgdhw2 |
EasyControl Adapter | boiler | 211 | tapactivated | turn on/off | boolean | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | |
EasyControl Adapter | boiler | 211 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp |
EasyControl Adapter | boiler | 211 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp |
EasyControl Adapter | boiler | 211 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow |
EasyControl Adapter | boiler | 211 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus |
EasyControl Adapter | boiler | 211 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff |
EasyControl Adapter | boiler | 211 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle |
EasyControl Adapter | boiler | 211 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp |
EasyControl Adapter | boiler | 211 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | |
EasyControl Adapter | boiler | 211 | comfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | |
EasyControl Adapter | boiler | 211 | comfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | |
EasyControl Adapter | boiler | 211 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset |
EasyControl Adapter | boiler | 211 | chargeoptimization | charge optimization | boolean | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | |
EasyControl Adapter | boiler | 211 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower |
EasyControl Adapter | boiler | 211 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp |
EasyControl Adapter | boiler | 211 | circpump | circulation pump available | boolean | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | |
EasyControl Adapter | boiler | 211 | chargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | |
EasyControl Adapter | boiler | 211 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston |
EasyControl Adapter | boiler | 211 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff |
EasyControl Adapter | boiler | 211 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp |
EasyControl Adapter | boiler | 211 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | |
EasyControl Adapter | boiler | 211 | circ | circulation active | boolean | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | |
EasyControl Adapter | boiler | 211 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp |
EasyControl Adapter | boiler | 211 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 |
EasyControl Adapter | boiler | 211 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow |
EasyControl Adapter | boiler | 211 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 |
EasyControl Adapter | boiler | 211 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 |
EasyControl Adapter | boiler | 211 | activated | activated | boolean | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | |
EasyControl Adapter | boiler | 211 | onetime | one time charging | boolean | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | |
EasyControl Adapter | boiler | 211 | disinfecting | disinfecting | boolean | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | |
EasyControl Adapter | boiler | 211 | charging | charging | boolean | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | |
EasyControl Adapter | boiler | 211 | recharging | recharging | boolean | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | |
EasyControl Adapter | boiler | 211 | tempok | temperature ok | boolean | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | |
EasyControl Adapter | boiler | 211 | active | active | boolean | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | |
EasyControl Adapter | boiler | 211 | 3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | |
EasyControl Adapter | boiler | 211 | setpumppower | set pump power | uint8 (>=0<=100) | % | False | sensor.boiler_dhw_set_pump_power | sensor.boiler_dhw_setpumppower |
EasyControl Adapter | boiler | 211 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp |
EasyControl Adapter | boiler | 211 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp |
EasyControl Adapter | boiler | 211 | starts | starts | uint24 (>=0<=16777213) | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | |
EasyControl Adapter | boiler | 211 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm |
EasyControl Adapter | boiler | 211 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower |
EasyControl Adapter | boiler | 211 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
EasyControl Adapter | boiler | 211 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat |
EasyControl Adapter | boiler | 211 | nrgdhw | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrgdhw |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | netflowtemp | heat network flow temp | uint16 (>=0<=3199) | C | False | sensor.boiler_heat_network_flow_temp | sensor.boiler_netflowtemp |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | heatvalve | heating valve | uint8 (>=0<=100) | % | False | sensor.boiler_heating_valve | sensor.boiler_heatvalve |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | dhwvalve | valve | uint8 (>=0<=100) | % | False | sensor.boiler_dhw_valve | sensor.boiler_dhw_dhwvalve |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | keepwarmtemp | keep warm temperature | uint8 (>=0<=254) | C | True | number.boiler_keep_warm_temperature | number.boiler_keepwarmtemp |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | setreturntemp | set temp return | uint8 (>=0<=254) | C | True | number.boiler_set_temp_return | number.boiler_setreturntemp |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | heating | heating | boolean | False | binary_sensor.boiler_heating | binary_sensor.boiler_heating | |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | reset | reset | cmd [-|maintenance|error|history|message] | True | sensor.boiler_reset | sensor.boiler_reset | |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | heatingoff | force heating off | boolean | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | setflowtemp | set flow temperature | uint8 (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | setburnpow | burner set power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | burnstarts | burner starts | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | servicecodenumber | service code number | uint16 (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | meterdhw | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meterdhw |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | gasmeterdhw | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeterdhw |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | nrgdhw2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrgdhw2 |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | tapactivated | turn on/off | boolean | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | comfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | comfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | chargeoptimization | charge optimization | boolean | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | circpump | circulation pump available | boolean | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | chargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | circ | circulation active | boolean | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | activated | activated | boolean | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | onetime | one time charging | boolean | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | disinfecting | disinfecting | boolean | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | charging | charging | boolean | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | recharging | recharging | boolean | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | tempok | temperature ok | boolean | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | active | active | boolean | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | 3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | setpumppower | set pump power | uint8 (>=0<=100) | % | False | sensor.boiler_dhw_set_pump_power | sensor.boiler_dhw_setpumppower |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | starts | starts | uint24 (>=0<=16777213) | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | |
Greenstar HIU/Logamax kompakt WS170 | boiler | 219 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm |
Logamax Plus GB122/Condense 2300 | boiler | 234 | reset | reset | cmd [-|maintenance|error|history|message] | True | sensor.boiler_reset | sensor.boiler_reset | |
Logamax Plus GB122/Condense 2300 | boiler | 234 | heatingoff | force heating off | boolean | True | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
Logamax Plus GB122/Condense 2300 | boiler | 234 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
Logamax Plus GB122/Condense 2300 | boiler | 234 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
Logamax Plus GB122/Condense 2300 | boiler | 234 | selflowtemp | selected flow temperature | uint8 (>=0<=90) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
Logamax Plus GB122/Condense 2300 | boiler | 234 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
Logamax Plus GB122/Condense 2300 | boiler | 234 | outdoortemp | outside temperature | int16 (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
Logamax Plus GB122/Condense 2300 | boiler | 234 | curflowtemp | current flow temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
Logamax Plus GB122/Condense 2300 | boiler | 234 | rettemp | return temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
Logamax Plus GB122/Condense 2300 | boiler | 234 | switchtemp | mixing switch temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
Logamax Plus GB122/Condense 2300 | boiler | 234 | syspress | system pressure | uint8 (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
Logamax Plus GB122/Condense 2300 | boiler | 234 | boiltemp | actual boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
Logamax Plus GB122/Condense 2300 | boiler | 234 | headertemp | low loss header | uint16 (>=0<=3199) | C | False | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
Logamax Plus GB122/Condense 2300 | boiler | 234 | exhausttemp | exhaust temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
Logamax Plus GB122/Condense 2300 | boiler | 234 | burngas | gas | boolean | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
Logamax Plus GB122/Condense 2300 | boiler | 234 | burngas2 | gas stage 2 | boolean | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
Logamax Plus GB122/Condense 2300 | boiler | 234 | flamecurr | flame current | uint16 (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr |
Logamax Plus GB122/Condense 2300 | boiler | 234 | fanwork | fan | boolean | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
Logamax Plus GB122/Condense 2300 | boiler | 234 | ignwork | ignition | boolean | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
Logamax Plus GB122/Condense 2300 | boiler | 234 | oilpreheat | oil preheating | boolean | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
Logamax Plus GB122/Condense 2300 | boiler | 234 | burnminpower | burner min power | uint8 (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower |
Logamax Plus GB122/Condense 2300 | boiler | 234 | burnmaxpower | burner max power | uint8 (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower |
Logamax Plus GB122/Condense 2300 | boiler | 234 | burnminperiod | burner min period | uint8 (>=0<=120) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod |
Logamax Plus GB122/Condense 2300 | boiler | 234 | absburnpow | burner current power (absolute) | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
Logamax Plus GB122/Condense 2300 | boiler | 234 | heatblock | heating block | uint16 (>=0<=3199) | C | False | sensor.boiler_heating_block | sensor.boiler_heatblock |
Logamax Plus GB122/Condense 2300 | boiler | 234 | boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
Logamax Plus GB122/Condense 2300 | boiler | 234 | boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
Logamax Plus GB122/Condense 2300 | boiler | 234 | boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
Logamax Plus GB122/Condense 2300 | boiler | 234 | boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
Logamax Plus GB122/Condense 2300 | boiler | 234 | curveon | heatingcurve on | boolean | True | switch.boiler_heatingcurve_on | switch.boiler_curveon | |
Logamax Plus GB122/Condense 2300 | boiler | 234 | curvebase | heatingcurve base | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_base | number.boiler_curvebase |
Logamax Plus GB122/Condense 2300 | boiler | 234 | curveend | heatingcurve end | uint8 (>=20<=90) | C | True | number.boiler_heatingcurve_end | number.boiler_curveend |
Logamax Plus GB122/Condense 2300 | boiler | 234 | summertemp | summer temperature | uint8 (>=0<=30) | C | True | number.boiler_summer_temperature | number.boiler_summertemp |
Logamax Plus GB122/Condense 2300 | boiler | 234 | nofrostmode | nofrost mode | boolean | True | switch.boiler_nofrost_mode | switch.boiler_nofrostmode | |
Logamax Plus GB122/Condense 2300 | boiler | 234 | nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | True | number.boiler_nofrost_temperature | number.boiler_nofrosttemp |
Logamax Plus GB122/Condense 2300 | boiler | 234 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
Logamax Plus GB122/Condense 2300 | boiler | 234 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
Logamax Plus GB122/Condense 2300 | boiler | 234 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
Logamax Plus GB122/Condense 2300 | boiler | 234 | pumpmodmax | boiler pump max power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
Logamax Plus GB122/Condense 2300 | boiler | 234 | pumpmodmin | boiler pump min power | uint8 (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
Logamax Plus GB122/Condense 2300 | boiler | 234 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
Logamax Plus GB122/Condense 2300 | boiler | 234 | pumpdelay | pump delay | uint8 (>=0<=60) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
Logamax Plus GB122/Condense 2300 | boiler | 234 | setflowtemp | set flow temperature | uint8 (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
Logamax Plus GB122/Condense 2300 | boiler | 234 | setburnpow | burner set power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
Logamax Plus GB122/Condense 2300 | boiler | 234 | selburnpow | burner selected max power | uint8 (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
Logamax Plus GB122/Condense 2300 | boiler | 234 | curburnpow | burner current power | uint8 (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
Logamax Plus GB122/Condense 2300 | boiler | 234 | burnstarts | burner starts | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
Logamax Plus GB122/Condense 2300 | boiler | 234 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
Logamax Plus GB122/Condense 2300 | boiler | 234 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
Logamax Plus GB122/Condense 2300 | boiler | 234 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
Logamax Plus GB122/Condense 2300 | boiler | 234 | heatstarts | burner starts heating | uint24 (>=0<=16777213) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
Logamax Plus GB122/Condense 2300 | boiler | 234 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
Logamax Plus GB122/Condense 2300 | boiler | 234 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
Logamax Plus GB122/Condense 2300 | boiler | 234 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
Logamax Plus GB122/Condense 2300 | boiler | 234 | servicecodenumber | service code number | uint16 (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
Logamax Plus GB122/Condense 2300 | boiler | 234 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
Logamax Plus GB122/Condense 2300 | boiler | 234 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
Logamax Plus GB122/Condense 2300 | boiler | 234 | maintenancetime | time to next maintenance | uint16 (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
Logamax Plus GB122/Condense 2300 | boiler | 234 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
Logamax Plus GB122/Condense 2300 | boiler | 234 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
Logamax Plus GB122/Condense 2300 | boiler | 234 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
Logamax Plus GB122/Condense 2300 | boiler | 234 | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_meter_heating | sensor.boiler_meterheat |
Logamax Plus GB122/Condense 2300 | boiler | 234 | meterdhw | meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_meter | sensor.boiler_dhw_meterdhw |
Logamax Plus GB122/Condense 2300 | boiler | 234 | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_gas_meter_heating | sensor.boiler_gasmeterheat |
Logamax Plus GB122/Condense 2300 | boiler | 234 | gasmeterdhw | gas meter | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_gas_meter | sensor.boiler_dhw_gasmeterdhw |
Logamax Plus GB122/Condense 2300 | boiler | 234 | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_energy_heating_2 | sensor.boiler_nrgheat2 |
Logamax Plus GB122/Condense 2300 | boiler | 234 | nrgdhw2 | energy 2 | uint24 (>=0<=1677721) | kWh | False | sensor.boiler_dhw_energy_2 | sensor.boiler_dhw_nrgdhw2 |
Logamax Plus GB122/Condense 2300 | boiler | 234 | tapactivated | turn on/off | boolean | True | switch.boiler_dhw_turn_on/off | switch.boiler_dhw_tapactivated | |
Logamax Plus GB122/Condense 2300 | boiler | 234 | settemp | set temperature | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_set_temperature | sensor.boiler_dhw_settemp |
Logamax Plus GB122/Condense 2300 | boiler | 234 | seltemp | selected temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_temperature | number.boiler_dhw_seltemp |
Logamax Plus GB122/Condense 2300 | boiler | 234 | seltemplow | selected lower temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_lower_temperature | number.boiler_dhw_seltemplow |
Logamax Plus GB122/Condense 2300 | boiler | 234 | tempecoplus | selected eco+ temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_selected_eco+_temperature | number.boiler_dhw_tempecoplus |
Logamax Plus GB122/Condense 2300 | boiler | 234 | seltempoff | selected temperature for off | uint8 (>=0<=254) | C | False | sensor.boiler_dhw_selected_temperature_for_off | sensor.boiler_dhw_seltempoff |
Logamax Plus GB122/Condense 2300 | boiler | 234 | seltempsingle | single charge temperature | uint8 (>=0<=254) | C | True | number.boiler_dhw_single_charge_temperature | number.boiler_dhw_seltempsingle |
Logamax Plus GB122/Condense 2300 | boiler | 234 | solartemp | solar boiler temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_solar_boiler_temperature | sensor.boiler_dhw_solartemp |
Logamax Plus GB122/Condense 2300 | boiler | 234 | type | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_dhw_type | sensor.boiler_dhw_type | |
Logamax Plus GB122/Condense 2300 | boiler | 234 | comfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_dhw_comfort | select.boiler_dhw_comfort | |
Logamax Plus GB122/Condense 2300 | boiler | 234 | comfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_dhw_comfort_mode | select.boiler_dhw_comfort1 | |
Logamax Plus GB122/Condense 2300 | boiler | 234 | flowtempoffset | flow temperature offset | uint8 (>=0<=100) | C | True | number.boiler_dhw_flow_temperature_offset | number.boiler_dhw_flowtempoffset |
Logamax Plus GB122/Condense 2300 | boiler | 234 | chargeoptimization | charge optimization | boolean | True | switch.boiler_dhw_charge_optimization | switch.boiler_dhw_chargeoptimization | |
Logamax Plus GB122/Condense 2300 | boiler | 234 | maxpower | max power | uint8 (>=0<=254) | % | True | number.boiler_dhw_max_power | number.boiler_dhw_maxpower |
Logamax Plus GB122/Condense 2300 | boiler | 234 | maxtemp | maximum temperature | uint8 (>=0<=80) | C | True | number.boiler_dhw_maximum_temperature | number.boiler_dhw_maxtemp |
Logamax Plus GB122/Condense 2300 | boiler | 234 | circpump | circulation pump available | boolean | True | switch.boiler_dhw_circulation_pump_available | switch.boiler_dhw_circpump | |
Logamax Plus GB122/Condense 2300 | boiler | 234 | chargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_dhw_charging_type | sensor.boiler_dhw_chargetype | |
Logamax Plus GB122/Condense 2300 | boiler | 234 | hyston | hysteresis on temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_on_temperature | number.boiler_dhw_hyston |
Logamax Plus GB122/Condense 2300 | boiler | 234 | hystoff | hysteresis off temperature | int8 (>=-126<=126) | C | True | number.boiler_dhw_hysteresis_off_temperature | number.boiler_dhw_hystoff |
Logamax Plus GB122/Condense 2300 | boiler | 234 | disinfectiontemp | disinfection temperature | uint8 (>=60<=80) | C | True | number.boiler_dhw_disinfection_temperature | number.boiler_dhw_disinfectiontemp |
Logamax Plus GB122/Condense 2300 | boiler | 234 | circmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_dhw_circulation_pump_mode | select.boiler_dhw_circmode | |
Logamax Plus GB122/Condense 2300 | boiler | 234 | circ | circulation active | boolean | True | switch.boiler_dhw_circulation_active | switch.boiler_dhw_circ | |
Logamax Plus GB122/Condense 2300 | boiler | 234 | curtemp | current intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_intern_temperature | sensor.boiler_dhw_curtemp |
Logamax Plus GB122/Condense 2300 | boiler | 234 | curtemp2 | current extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_current_extern_temperature | sensor.boiler_dhw_curtemp2 |
Logamax Plus GB122/Condense 2300 | boiler | 234 | curflow | current tap water flow | uint8 (>=0<=25) | l/min | False | sensor.boiler_dhw_current_tap_water_flow | sensor.boiler_dhw_curflow |
Logamax Plus GB122/Condense 2300 | boiler | 234 | storagetemp1 | storage intern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_intern_temperature | sensor.boiler_dhw_storagetemp1 |
Logamax Plus GB122/Condense 2300 | boiler | 234 | storagetemp2 | storage extern temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_storage_extern_temperature | sensor.boiler_dhw_storagetemp2 |
Logamax Plus GB122/Condense 2300 | boiler | 234 | activated | activated | boolean | True | switch.boiler_dhw_activated | switch.boiler_dhw_activated | |
Logamax Plus GB122/Condense 2300 | boiler | 234 | onetime | one time charging | boolean | True | switch.boiler_dhw_one_time_charging | switch.boiler_dhw_onetime | |
Logamax Plus GB122/Condense 2300 | boiler | 234 | disinfecting | disinfecting | boolean | True | switch.boiler_dhw_disinfecting | switch.boiler_dhw_disinfecting | |
Logamax Plus GB122/Condense 2300 | boiler | 234 | charging | charging | boolean | False | binary_sensor.boiler_dhw_charging | binary_sensor.boiler_dhw_charging | |
Logamax Plus GB122/Condense 2300 | boiler | 234 | recharging | recharging | boolean | False | binary_sensor.boiler_dhw_recharging | binary_sensor.boiler_dhw_recharging | |
Logamax Plus GB122/Condense 2300 | boiler | 234 | tempok | temperature ok | boolean | False | binary_sensor.boiler_dhw_temperature_ok | binary_sensor.boiler_dhw_tempok | |
Logamax Plus GB122/Condense 2300 | boiler | 234 | active | active | boolean | False | binary_sensor.boiler_dhw_active | binary_sensor.boiler_dhw_active | |
Logamax Plus GB122/Condense 2300 | boiler | 234 | 3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_dhw_3-way_valve_active | binary_sensor.boiler_dhw_3wayvalve | |
Logamax Plus GB122/Condense 2300 | boiler | 234 | setpumppower | set pump power | uint8 (>=0<=100) | % | False | sensor.boiler_dhw_set_pump_power | sensor.boiler_dhw_setpumppower |
Logamax Plus GB122/Condense 2300 | boiler | 234 | mixertemp | mixer temperature | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_mixer_temperature | sensor.boiler_dhw_mixertemp |
Logamax Plus GB122/Condense 2300 | boiler | 234 | cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | False | sensor.boiler_dhw_cylinder_middle_temperature_(TS3) | sensor.boiler_dhw_cylmiddletemp |
Logamax Plus GB122/Condense 2300 | boiler | 234 | starts | starts | uint24 (>=0<=16777213) | False | sensor.boiler_dhw_starts | sensor.boiler_dhw_starts | |
Logamax Plus GB122/Condense 2300 | boiler | 234 | workm | active time | time (>=0<=16777213) | minutes | False | sensor.boiler_dhw_active_time | sensor.boiler_dhw_workm |
Logamax Plus GB122/Condense 2300 | boiler | 234 | nompower | nominal Power | uint8 (>=0<=254) | kW | True | number.boiler_nominal_Power | number.boiler_nompower |
Logamax Plus GB122/Condense 2300 | boiler | 234 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
Logamax Plus GB122/Condense 2300 | boiler | 234 | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | True | number.boiler_energy_heating | number.boiler_nrgheat |
Logamax Plus GB122/Condense 2300 | boiler | 234 | nrgdhw | energy | uint24 (>=0<=10000000) | kWh | True | number.boiler_dhw_energy | number.boiler_dhw_nrgdhw |
Logamatic TC100/Moduline Easy | thermostat | 202 | errorcode | error code | string | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | |
Logamatic TC100/Moduline Easy | thermostat | 202 | lastcode | last error code | string | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | |
Logamatic TC100/Moduline Easy | thermostat | 202 | datetime | date/time | string | False | sensor.thermostat_date/time | sensor.thermostat_datetime | |
Logamatic TC100/Moduline Easy | thermostat | 202 | seltemp | selected room temperature | int16 (>=-319<=319) | C | False | sensor.thermostat_hc1_selected_room_temperature | sensor.thermostat_hc1_seltemp |
Logamatic TC100/Moduline Easy | thermostat | 202 | currtemp | current room temperature | int16 (>=-319<=319) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp |
Logamatic TC100/Moduline Easy | thermostat | 202 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | |
EasyControl/CT200 | thermostat | 203 | errorcode | error code | string | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | |
EasyControl/CT200 | thermostat | 203 | lastcode | last error code | string | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | |
EasyControl/CT200 | thermostat | 203 | datetime | date/time | string | False | sensor.thermostat_date/time | sensor.thermostat_datetime | |
EasyControl/CT200 | thermostat | 203 | seltemp | selected room temperature | int16 (>=-319<=319) | C | False | sensor.thermostat_hc1_selected_room_temperature | sensor.thermostat_hc1_seltemp |
EasyControl/CT200 | thermostat | 203 | currtemp | current room temperature | int16 (>=-319<=319) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp |
EasyControl/CT200 | thermostat | 203 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | |
UI800/BC400 | thermostat | 4 | errorcode | error code | string | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | |
UI800/BC400 | thermostat | 4 | lastcode | last error code | string | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | |
UI800/BC400 | thermostat | 4 | datetime | date/time | string | True | sensor.thermostat_date/time | sensor.thermostat_datetime | |
UI800/BC400 | thermostat | 4 | intoffset | internal temperature offset | int8 (>=-12<=12) | C | True | number.thermostat_internal_temperature_offset | number.thermostat_intoffset |
UI800/BC400 | thermostat | 4 | floordry | floor drying | enum [off|start|heat|hold|cool|end] | False | sensor.thermostat_floor_drying | sensor.thermostat_floordry | |
UI800/BC400 | thermostat | 4 | dampedoutdoortemp | damped outdoor temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_damped_outdoor_temperature | sensor.thermostat_dampedoutdoortemp |
UI800/BC400 | thermostat | 4 | floordrytemp | floor drying temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_floor_drying_temperature | sensor.thermostat_floordrytemp |
UI800/BC400 | thermostat | 4 | building | building type | enum [light|medium|heavy] | True | select.thermostat_building_type | select.thermostat_building | |
UI800/BC400 | thermostat | 4 | minexttemp | minimal external temperature | int8 (>=-126<=126) | C | True | number.thermostat_minimal_external_temperature | number.thermostat_minexttemp |
UI800/BC400 | thermostat | 4 | damping | damping outdoor temperature | boolean | True | switch.thermostat_damping_outdoor_temperature | switch.thermostat_damping | |
UI800/BC400 | thermostat | 4 | hybridstrategy | hybrid control strategy | enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] | True | select.thermostat_hybrid_control_strategy | select.thermostat_hybridstrategy | |
UI800/BC400 | thermostat | 4 | switchovertemp | outside switchover temperature | int8 (>=-20<=20) | C | True | number.thermostat_outside_switchover_temperature | number.thermostat_switchovertemp |
UI800/BC400 | thermostat | 4 | energycostratio | energy cost ratio | uint8 (>=0<=20) | True | number.thermostat_energy_cost_ratio | number.thermostat_energycostratio | |
UI800/BC400 | thermostat | 4 | fossilefactor | fossile energy factor | uint8 (>=0<=5) | True | number.thermostat_fossile_energy_factor | number.thermostat_fossilefactor | |
UI800/BC400 | thermostat | 4 | electricfactor | electric energy factor | uint8 (>=0<=5) | True | number.thermostat_electric_energy_factor | number.thermostat_electricfactor | |
UI800/BC400 | thermostat | 4 | delayboiler | delay boiler support | uint8 (>=5<=120) | minutes | True | number.thermostat_delay_boiler_support | number.thermostat_delayboiler |
UI800/BC400 | thermostat | 4 | tempdiffboiler | temp diff boiler support | uint8 (>=1<=99) | C | True | number.thermostat_temp_diff_boiler_support | number.thermostat_tempdiffboiler |
UI800/BC400 | thermostat | 4 | pvenabledhw | enable raise dhw | boolean | True | switch.thermostat_enable_raise_dhw | switch.thermostat_pvenabledhw | |
UI800/BC400 | thermostat | 4 | pvraiseheat | raise heating with PV | int8 (>=0<=5) | K | True | number.thermostat_raise_heating_with_PV | number.thermostat_pvraiseheat |
UI800/BC400 | thermostat | 4 | pvlowercool | lower cooling with PV | int8 (>=-5<=0) | K | True | number.thermostat_lower_cooling_with_PV | number.thermostat_pvlowercool |
UI800/BC400 | thermostat | 4 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp |
UI800/BC400 | thermostat | 4 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp |
UI800/BC400 | thermostat | 4 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | |
UI800/BC400 | thermostat | 4 | mode | mode | enum [off|manual|auto] | True | select.thermostat_hc1_mode | select.thermostat_hc1_mode | |
UI800/BC400 | thermostat | 4 | modetype | mode type | enum [eco|comfort] | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | |
UI800/BC400 | thermostat | 4 | ecotemp | eco temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_eco_temperature | number.thermostat_hc1_ecotemp |
UI800/BC400 | thermostat | 4 | manualtemp | manual temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_manual_temperature | number.thermostat_hc1_manualtemp |
UI800/BC400 | thermostat | 4 | comforttemp | comfort temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_comfort_temperature | number.thermostat_hc1_comforttemp |
UI800/BC400 | thermostat | 4 | summertemp | summer temperature | uint8 (>=10<=30) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp |
UI800/BC400 | thermostat | 4 | designtemp | design temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_design_temperature | number.thermostat_hc1_designtemp |
UI800/BC400 | thermostat | 4 | offsettemp | offset temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_offset_temperature | number.thermostat_hc1_offsettemp |
UI800/BC400 | thermostat | 4 | minflowtemp | min flow temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp |
UI800/BC400 | thermostat | 4 | maxflowtemp | max flow temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp |
UI800/BC400 | thermostat | 4 | roominfluence | room influence | uint8 (>=0<=254) | C | True | number.thermostat_hc1_room_influence | number.thermostat_hc1_roominfluence |
UI800/BC400 | thermostat | 4 | roominflfactor | room influence factor | uint8 (>=0<=25) | True | number.thermostat_hc1_room_influence_factor | number.thermostat_hc1_roominflfactor | |
UI800/BC400 | thermostat | 4 | curroominfl | current room influence | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_influence | sensor.thermostat_hc1_curroominfl |
UI800/BC400 | thermostat | 4 | nofrostmode | nofrost mode | enum [room|outdoor|room outdoor] | True | select.thermostat_hc1_nofrost_mode | select.thermostat_hc1_nofrostmode | |
UI800/BC400 | thermostat | 4 | nofrosttemp | nofrost temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_nofrost_temperature | number.thermostat_hc1_nofrosttemp |
UI800/BC400 | thermostat | 4 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp |
UI800/BC400 | thermostat | 4 | heatingtype | heating type | enum [off|radiator|convector|floor] | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | |
UI800/BC400 | thermostat | 4 | summersetmode | set summer mode | enum [summer|auto|winter] | True | select.thermostat_hc1_set_summer_mode | select.thermostat_hc1_summersetmode | |
UI800/BC400 | thermostat | 4 | hpoperatingmode | heatpump operating mode | enum [off|auto|heating|cooling] | True | select.thermostat_hc1_heatpump_operating_mode | select.thermostat_hc1_hpoperatingmode | |
UI800/BC400 | thermostat | 4 | summermode | summer mode | enum [winter|summer] | False | sensor.thermostat_hc1_summer_mode | sensor.thermostat_hc1_summermode | |
UI800/BC400 | thermostat | 4 | hpoperatingstate | heatpump operating state | enum [heating|off|cooling] | False | sensor.thermostat_hc1_heatpump_operating_state | sensor.thermostat_hc1_hpoperatingstate | |
UI800/BC400 | thermostat | 4 | controlmode | control mode | enum [weather compensated|outside basepoint|n/a|room|power|constant] | True | select.thermostat_hc1_control_mode | select.thermostat_hc1_controlmode | |
UI800/BC400 | thermostat | 4 | program | program | enum [prog 1|prog 2] | True | select.thermostat_hc1_program | select.thermostat_hc1_program | |
UI800/BC400 | thermostat | 4 | tempautotemp | temporary set temperature automode | int8 (>=-1<=30) | C | True | number.thermostat_hc1_temporary_set_temperature_automode | number.thermostat_hc1_tempautotemp |
UI800/BC400 | thermostat | 4 | remoteseltemp | temporary set temperature from remote | int8 (>=-63<=63) | C | False | sensor.thermostat_hc1_temporary_set_temperature_from_remote | sensor.thermostat_hc1_remoteseltemp |
UI800/BC400 | thermostat | 4 | fastheatup | fast heatup | uint8 (>=0<=100) | % | True | number.thermostat_hc1_fast_heatup | number.thermostat_hc1_fastheatup |
UI800/BC400 | thermostat | 4 | switchonoptimization | switch-on optimization | boolean | True | switch.thermostat_hc1_switch-on_optimization | switch.thermostat_hc1_switchonoptimization | |
UI800/BC400 | thermostat | 4 | reducemode | reduce mode | enum [outdoor|room|reduce] | True | select.thermostat_hc1_reduce_mode | select.thermostat_hc1_reducemode | |
UI800/BC400 | thermostat | 4 | noreducetemp | no reduce below temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_no_reduce_below_temperature | number.thermostat_hc1_noreducetemp |
UI800/BC400 | thermostat | 4 | reducetemp | off/reduce switch temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_off/reduce_switch_temperature | number.thermostat_hc1_reducetemp |
UI800/BC400 | thermostat | 4 | dhwprio | dhw priority | boolean | True | switch.thermostat_hc1_dhw_priority | switch.thermostat_hc1_dhwprio | |
UI800/BC400 | thermostat | 4 | cooling | cooling | boolean | True | switch.thermostat_hc1_cooling | switch.thermostat_hc1_cooling | |
UI800/BC400 | thermostat | 4 | coolingon | cooling | boolean | False | binary_sensor.thermostat_hc1_cooling | binary_sensor.thermostat_hc1_coolingon | |
UI800/BC400 | thermostat | 4 | hpmode | HP Mode | enum [heating|cooling|heating&cooling] | True | select.thermostat_hc1_HP_Mode | select.thermostat_hc1_hpmode | |
UI800/BC400 | thermostat | 4 | dewoffset | dew point offset | uint8 (>=2<=10) | K | True | number.thermostat_hc1_dew_point_offset | number.thermostat_hc1_dewoffset |
UI800/BC400 | thermostat | 4 | roomtempdiff | room temp difference | uint8 (>=0<=254) | K | True | number.thermostat_hc1_room_temp_difference | number.thermostat_hc1_roomtempdiff |
UI800/BC400 | thermostat | 4 | hpminflowtemp | HP min. flow temp. | uint8 (>=0<=254) | C | True | number.thermostat_hc1_HP_min._flow_temp. | number.thermostat_hc1_hpminflowtemp |
UI800/BC400 | thermostat | 4 | control | control device | enum [RC310|RC200|RC100|RC100H|TC100] | True | select.thermostat_hc1_control_device | select.thermostat_hc1_control | |
UI800/BC400 | thermostat | 4 | remotetemp | room temperature from remote | int16 (>=-1<=101) | C | True | number.thermostat_hc1_room_temperature_from_remote | number.thermostat_hc1_remotetemp |
UI800/BC400 | thermostat | 4 | remotehum | room humidity from remote | uint8 (>=-1<=101) | % | True | number.thermostat_hc1_room_humidity_from_remote | number.thermostat_hc1_remotehum |
UI800/BC400 | thermostat | 4 | heatondelay | heat-on delay | uint8 (>=1<=48) | hours | True | number.thermostat_hc1_heat-on_delay | number.thermostat_hc1_heatondelay |
UI800/BC400 | thermostat | 4 | heatoffdelay | heat-off delay | uint8 (>=1<=48) | hours | True | number.thermostat_hc1_heat-off_delay | number.thermostat_hc1_heatoffdelay |
UI800/BC400 | thermostat | 4 | instantstart | instant start | uint8 (>=1<=10) | K | True | number.thermostat_hc1_instant_start | number.thermostat_hc1_instantstart |
UI800/BC400 | thermostat | 4 | boost | boost mode | boolean | True | switch.thermostat_hc1_boost_mode | switch.thermostat_hc1_boost | |
UI800/BC400 | thermostat | 4 | boosttime | boost time | uint8 (>=0<=254) | hours | True | number.thermostat_hc1_boost_time | number.thermostat_hc1_boosttime |
UI800/BC400 | thermostat | 4 | mode | mode | enum [off|eco+|eco|comfort|auto] | True | select.thermostat_dhw_mode | select.thermostat_dhw_mode | |
UI800/BC400 | thermostat | 4 | settemp | set temperature | uint8 (>=0<=254) | C | True | number.thermostat_dhw_set_temperature | number.thermostat_dhw_settemp |
UI800/BC400 | thermostat | 4 | settemplow | set low temperature | uint8 (>=0<=254) | C | True | number.thermostat_dhw_set_low_temperature | number.thermostat_dhw_settemplow |
UI800/BC400 | thermostat | 4 | circmode | circulation pump mode | enum [off|on|auto|own prog] | True | select.thermostat_dhw_circulation_pump_mode | select.thermostat_dhw_circmode | |
UI800/BC400 | thermostat | 4 | chargeduration | charge duration | uint8 (>=0<=3810) | minutes | True | number.thermostat_dhw_charge_duration | number.thermostat_dhw_chargeduration |
UI800/BC400 | thermostat | 4 | charge | charge | boolean | True | switch.thermostat_dhw_charge | switch.thermostat_dhw_charge | |
UI800/BC400 | thermostat | 4 | extra | extra | uint8 (>=0<=254) | C | False | sensor.thermostat_dhw_extra | sensor.thermostat_dhw_extra |
UI800/BC400 | thermostat | 4 | disinfecting | disinfecting | boolean | True | switch.thermostat_dhw_disinfecting | switch.thermostat_dhw_disinfecting | |
UI800/BC400 | thermostat | 4 | disinfectday | disinfection day | enum [mo|tu|we|th|fr|sa|su|all] | True | select.thermostat_dhw_disinfection_day | select.thermostat_dhw_disinfectday | |
UI800/BC400 | thermostat | 4 | disinfecttime | disinfection time | uint8 (>=0<=1431) | minutes | True | number.thermostat_dhw_disinfection_time | number.thermostat_dhw_disinfecttime |
UI800/BC400 | thermostat | 4 | dailyheating | daily heating | boolean | True | switch.thermostat_dhw_daily_heating | switch.thermostat_dhw_dailyheating | |
UI800/BC400 | thermostat | 4 | dailyheattime | daily heating time | uint8 (>=0<=1431) | minutes | True | number.thermostat_dhw_daily_heating_time | number.thermostat_dhw_dailyheattime |
RC10 | thermostat | 65 | errorcode | error code | string | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | |
RC10 | thermostat | 65 | lastcode | last error code | string | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | |
RC10 | thermostat | 65 | datetime | date/time | string | False | sensor.thermostat_date/time | sensor.thermostat_datetime | |
RC10 | thermostat | 65 | minexttemp | minimal external temperature | int8 (>=-126<=126) | C | True | number.thermostat_minimal_external_temperature | number.thermostat_minexttemp |
RC10 | thermostat | 65 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp |
RC10 | thermostat | 65 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp |
RC10 | thermostat | 65 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | |
RC10 | thermostat | 65 | mode | mode | enum [night|day|auto] | True | select.thermostat_hc1_mode | select.thermostat_hc1_mode | |
RC10 | thermostat | 65 | modetype | mode type | enum [night|day] | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | |
RC10 | thermostat | 65 | daytemp | day temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_day_temperature | number.thermostat_hc1_daytemp |
RC10 | thermostat | 65 | nighttemp | night temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_night_temperature | number.thermostat_hc1_nighttemp |
RC10 | thermostat | 65 | program | program | enum [family|morning|evening|am|pm|midday|singles|seniors] | True | select.thermostat_hc1_program | select.thermostat_hc1_program | |
RC10 | thermostat | 65 | minflowtemp | min flow temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp |
RC10 | thermostat | 65 | maxflowtemp | max flow temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp |
RC10 | thermostat | 65 | tempautotemp | temporary set temperature automode | uint8 (>=0<=127) | C | True | number.thermostat_hc1_temporary_set_temperature_automode | number.thermostat_hc1_tempautotemp |
RC10 | thermostat | 65 | heatingtype | heating type | enum [off|radiator|convector|floor] | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | |
RC10 | thermostat | 65 | summertemp | summer temperature | uint8 (>=10<=30) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp |
RC10 | thermostat | 65 | summermode | summer mode | enum [winter|summer] | False | sensor.thermostat_hc1_summer_mode | sensor.thermostat_hc1_summermode | |
RC10 | thermostat | 65 | remotetemp | room temperature from remote | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_room_temperature_from_remote | sensor.thermostat_hc1_remotetemp |
RC30 | thermostat | 67 | errorcode | error code | string | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | |
RC30 | thermostat | 67 | lastcode | last error code | string | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | |
RC30 | thermostat | 67 | datetime | date/time | string | False | sensor.thermostat_date/time | sensor.thermostat_datetime | |
RC30 | thermostat | 67 | display | display | enum [internal temperature|internal setpoint|external temperature|burner temperature|dhw temperature|functioning mode|time|date|smoke temperature] | True | select.thermostat_display | select.thermostat_display | |
RC30 | thermostat | 67 | language | language | enum [german|dutch|french|italian] | False | sensor.thermostat_language | sensor.thermostat_language | |
RC30 | thermostat | 67 | clockoffset | clock offset | int8 (>=-126<=126) | seconds | True | number.thermostat_clock_offset | number.thermostat_clockoffset |
RC30 | thermostat | 67 | intoffset | internal temperature offset | int8 (>=-12<=12) | C | True | number.thermostat_internal_temperature_offset | number.thermostat_intoffset |
RC30 | thermostat | 67 | minexttemp | minimal external temperature | int8 (>=-126<=126) | C | True | number.thermostat_minimal_external_temperature | number.thermostat_minexttemp |
RC30 | thermostat | 67 | inttemp1 | temperature sensor 1 | int16 (>=-3199<=3199) | C | False | sensor.thermostat_temperature_sensor_1 | sensor.thermostat_inttemp1 |
RC30 | thermostat | 67 | inttemp2 | temperature sensor 2 | int16 (>=-3199<=3199) | C | False | sensor.thermostat_temperature_sensor_2 | sensor.thermostat_inttemp2 |
RC30 | thermostat | 67 | damping | damping outdoor temperature | boolean | True | switch.thermostat_damping_outdoor_temperature | switch.thermostat_damping | |
RC30 | thermostat | 67 | dampedoutdoortemp | damped outdoor temperature | int8 (>=-126<=126) | C | False | sensor.thermostat_damped_outdoor_temperature | sensor.thermostat_dampedoutdoortemp |
RC30 | thermostat | 67 | building | building type | enum [light|medium|heavy] | True | select.thermostat_building_type | select.thermostat_building | |
RC30 | thermostat | 67 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp |
RC30 | thermostat | 67 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp |
RC30 | thermostat | 67 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | |
RC30 | thermostat | 67 | mode | mode | enum [night|day|auto] | True | select.thermostat_hc1_mode | select.thermostat_hc1_mode | |
RC30 | thermostat | 67 | modetype | mode type | enum [night|day] | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | |
RC30 | thermostat | 67 | daytemp | day temperature | uint8 (>=10<=30) | C | True | number.thermostat_hc1_day_temperature | number.thermostat_hc1_daytemp |
RC30 | thermostat | 67 | nighttemp | night temperature | uint8 (>=10<=30) | C | True | number.thermostat_hc1_night_temperature | number.thermostat_hc1_nighttemp |
RC30 | thermostat | 67 | designtemp | design temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_design_temperature | number.thermostat_hc1_designtemp |
RC30 | thermostat | 67 | offsettemp | offset temperature | int8 (>=-5<=5) | C | True | number.thermostat_hc1_offset_temperature | number.thermostat_hc1_offsettemp |
RC30 | thermostat | 67 | holidaytemp | holiday temperature | uint8 (>=5<=30) | C | True | number.thermostat_hc1_holiday_temperature | number.thermostat_hc1_holidaytemp |
RC30 | thermostat | 67 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp |
RC30 | thermostat | 67 | summertemp | summer temperature | uint8 (>=9<=25) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp |
RC30 | thermostat | 67 | summermode | summer mode | enum [winter|summer] | False | sensor.thermostat_hc1_summer_mode | sensor.thermostat_hc1_summermode | |
RC30 | thermostat | 67 | holidaymode | holiday mode | boolean | False | binary_sensor.thermostat_hc1_holiday_mode | binary_sensor.thermostat_hc1_holidaymode | |
RC30 | thermostat | 67 | nofrosttemp | nofrost temperature | int8 (>=-20<=10) | C | True | number.thermostat_hc1_nofrost_temperature | number.thermostat_hc1_nofrosttemp |
RC30 | thermostat | 67 | nofrostmode | nofrost mode | enum [off|outdoor|room] | True | select.thermostat_hc1_nofrost_mode | select.thermostat_hc1_nofrostmode | |
RC30 | thermostat | 67 | roominfluence | room influence | uint8 (>=0<=10) | C | True | number.thermostat_hc1_room_influence | number.thermostat_hc1_roominfluence |
RC30 | thermostat | 67 | minflowtemp | min flow temperature | uint8 (>=5<=70) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp |
RC30 | thermostat | 67 | maxflowtemp | max flow temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp |
RC30 | thermostat | 67 | flowtempoffset | flow temperature offset for mixer | uint8 (>=0<=20) | C | True | number.thermostat_hc1_flow_temperature_offset_for_mixer | number.thermostat_hc1_flowtempoffset |
RC30 | thermostat | 67 | heatingtype | heating type | enum [off|radiator|convector|floor] | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | |
RC30 | thermostat | 67 | reducemode | reduce mode | enum [nofrost|reduce|room|outdoor] | True | select.thermostat_hc1_reduce_mode | select.thermostat_hc1_reducemode | |
RC30 | thermostat | 67 | controlmode | control mode | enum [outdoor|room] | True | select.thermostat_hc1_control_mode | select.thermostat_hc1_controlmode | |
RC30 | thermostat | 67 | control | control device | enum [off|RC20|RC3x] | True | select.thermostat_hc1_control_device | select.thermostat_hc1_control | |
RC30 | thermostat | 67 | holidays | holiday dates | string | True | sensor.thermostat_hc1_holiday_dates | sensor.thermostat_hc1_holidays | |
RC30 | thermostat | 67 | vacations | vacation dates | string | True | sensor.thermostat_hc1_vacation_dates | sensor.thermostat_hc1_vacations | |
RC30 | thermostat | 67 | program | program | enum [own 1|family|morning|evening|am|pm|midday|singles|seniors|new|own 2] | True | select.thermostat_hc1_program | select.thermostat_hc1_program | |
RC30 | thermostat | 67 | pause | pause time | uint8 (>=0<=99) | hours | True | number.thermostat_hc1_pause_time | number.thermostat_hc1_pause |
RC30 | thermostat | 67 | party | party time | uint8 (>=0<=99) | hours | True | number.thermostat_hc1_party_time | number.thermostat_hc1_party |
RC30 | thermostat | 67 | tempautotemp | temporary set temperature automode | uint8 (>=0<=30) | C | True | number.thermostat_hc1_temporary_set_temperature_automode | number.thermostat_hc1_tempautotemp |
RC30 | thermostat | 67 | noreducetemp | no reduce below temperature | int8 (>=-31<=10) | C | True | number.thermostat_hc1_no_reduce_below_temperature | number.thermostat_hc1_noreducetemp |
RC30 | thermostat | 67 | reducetemp | off/reduce switch temperature | int8 (>=-20<=10) | C | True | number.thermostat_hc1_off/reduce_switch_temperature | number.thermostat_hc1_reducetemp |
RC30 | thermostat | 67 | vacreducetemp | vacations off/reduce switch temperature | int8 (>=-20<=10) | C | True | number.thermostat_hc1_vacations_off/reduce_switch_temperature | number.thermostat_hc1_vacreducetemp |
RC30 | thermostat | 67 | vacreducemode | vacations reduce mode | enum [nofrost|reduce|room|outdoor] | True | select.thermostat_hc1_vacations_reduce_mode | select.thermostat_hc1_vacreducemode | |
RC30 | thermostat | 67 | remotetemp | room temperature from remote | int16 (>=-1<=101) | C | True | number.thermostat_hc1_room_temperature_from_remote | number.thermostat_hc1_remotetemp |
RC30 | thermostat | 67 | dhwprio | dhw priority | boolean | True | switch.thermostat_hc1_dhw_priority | switch.thermostat_hc1_dhwprio | |
RC30 | thermostat | 67 | switchonoptimization | switch-on optimization | boolean | True | switch.thermostat_hc1_switch-on_optimization | switch.thermostat_hc1_switchonoptimization | |
RC30 | thermostat | 67 | switchtime1 | own1 program switchtime | string | True | sensor.thermostat_hc1_own1_program_switchtime | sensor.thermostat_hc1_switchtime1 | |
RC30 | thermostat | 67 | switchtime2 | own2 program switchtime | string | True | sensor.thermostat_hc1_own2_program_switchtime | sensor.thermostat_hc1_switchtime2 | |
RC30 | thermostat | 67 | mode | mode | enum [off|on|auto] | True | select.thermostat_dhw_mode | select.thermostat_dhw_mode | |
RC30 | thermostat | 67 | circmode | circulation pump mode | enum [off|on|auto] | True | select.thermostat_dhw_circulation_pump_mode | select.thermostat_dhw_circmode | |
RC30 | thermostat | 67 | progmode | program | enum [std prog|own prog] | True | select.thermostat_dhw_program | select.thermostat_dhw_progmode | |
RC30 | thermostat | 67 | circprog | circulation program | enum [std prog|own prog] | True | select.thermostat_dhw_circulation_program | select.thermostat_dhw_circprog | |
RC30 | thermostat | 67 | disinfecting | disinfecting | boolean | True | switch.thermostat_dhw_disinfecting | switch.thermostat_dhw_disinfecting | |
RC30 | thermostat | 67 | disinfectday | disinfection day | enum [mo|tu|we|th|fr|sa|su|all] | True | select.thermostat_dhw_disinfection_day | select.thermostat_dhw_disinfectday | |
RC30 | thermostat | 67 | disinfecthour | disinfection hour | uint8 (>=0<=23) | True | number.thermostat_dhw_disinfection_hour | number.thermostat_dhw_disinfecthour | |
RC30 | thermostat | 67 | maxtemp | maximum temperature | uint8 (>=0<=254) | C | True | number.thermostat_dhw_maximum_temperature | number.thermostat_dhw_maxtemp |
RC30 | thermostat | 67 | onetimekey | one time key function | boolean | True | switch.thermostat_dhw_one_time_key_function | switch.thermostat_dhw_onetimekey | |
RC30 | thermostat | 67 | switchtime | program switchtime | string | True | sensor.thermostat_dhw_program_switchtime | sensor.thermostat_dhw_switchtime | |
RC30 | thermostat | 67 | circswitchtime | circulation program switchtime | string | True | sensor.thermostat_dhw_circulation_program_switchtime | sensor.thermostat_dhw_circswitchtime | |
RC30 | thermostat | 67 | holidays | holiday dates | string | True | sensor.thermostat_dhw_holiday_dates | sensor.thermostat_dhw_holidays | |
RC30 | thermostat | 67 | vacations | vacation dates | string | True | sensor.thermostat_dhw_vacation_dates | sensor.thermostat_dhw_vacations | |
RC20/Moduline 300 | thermostat | 77 | errorcode | error code | string | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | |
RC20/Moduline 300 | thermostat | 77 | lastcode | last error code | string | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | |
RC20/Moduline 300 | thermostat | 77 | datetime | date/time | string | False | sensor.thermostat_date/time | sensor.thermostat_datetime | |
RC20/Moduline 300 | thermostat | 77 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp |
RC20/Moduline 300 | thermostat | 77 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp |
RC20/Moduline 300 | thermostat | 77 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | |
RC20/Moduline 300 | thermostat | 77 | mode | mode | enum [off|manual|auto] | True | select.thermostat_hc1_mode | select.thermostat_hc1_mode | |
RC20/Moduline 300 | thermostat | 77 | manualtemp | manual temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_manual_temperature | number.thermostat_hc1_manualtemp |
RC20/Moduline 300 | thermostat | 77 | offtemp | temperature when mode is off | uint8 (>=0<=127) | C | True | number.thermostat_hc1_temperature_when_mode_is_off | number.thermostat_hc1_offtemp |
RC20/Moduline 300 | thermostat | 77 | daytemp2 | day temperature T2 | uint8 (>=0<=127) | C | True | number.thermostat_hc1_day_temperature_T2 | number.thermostat_hc1_daytemp2 |
RC20/Moduline 300 | thermostat | 77 | daytemp3 | day temperature T3 | uint8 (>=0<=127) | C | True | number.thermostat_hc1_day_temperature_T3 | number.thermostat_hc1_daytemp3 |
RC20/Moduline 300 | thermostat | 77 | daytemp4 | day temperature T4 | uint8 (>=0<=127) | C | True | number.thermostat_hc1_day_temperature_T4 | number.thermostat_hc1_daytemp4 |
RC20/Moduline 300 | thermostat | 77 | nighttemp | night temperature T1 | uint8 (>=0<=127) | C | True | number.thermostat_hc1_night_temperature_T1 | number.thermostat_hc1_nighttemp |
RC20/Moduline 300 | thermostat | 77 | switchtime | program switchtime | string | True | sensor.thermostat_hc1_program_switchtime | sensor.thermostat_hc1_switchtime | |
Moduline 400 | thermostat | 78 | errorcode | error code | string | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | |
Moduline 400 | thermostat | 78 | lastcode | last error code | string | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | |
Moduline 400 | thermostat | 78 | datetime | date/time | string | False | sensor.thermostat_date/time | sensor.thermostat_datetime | |
Moduline 400 | thermostat | 78 | clockoffset | clock offset | int8 (>=-126<=126) | seconds | True | number.thermostat_clock_offset | number.thermostat_clockoffset |
Moduline 400 | thermostat | 78 | autodst | automatic change daylight saving time | boolean | True | switch.thermostat_automatic_change_daylight_saving_time | switch.thermostat_autodst | |
Moduline 400 | thermostat | 78 | language | language | enum [german|dutch] | True | select.thermostat_language | select.thermostat_language | |
Moduline 400 | thermostat | 78 | backlight | key backlight | boolean | True | switch.thermostat_key_backlight | switch.thermostat_backlight | |
Moduline 400 | thermostat | 78 | brightness | screen brightness | int8 (>=-15<=15) | True | number.thermostat_screen_brightness | number.thermostat_brightness | |
Moduline 400 | thermostat | 78 | mixingvalves | mixing valves | uint8 (>=0<=2) | True | number.thermostat_mixing_valves | number.thermostat_mixingvalves | |
Moduline 400 | thermostat | 78 | building | building type | enum [light|medium|heavy] | True | select.thermostat_building_type | select.thermostat_building | |
Moduline 400 | thermostat | 78 | heatingpid | heating PID | enum [fast|medium|slow] | True | select.thermostat_heating_PID | select.thermostat_heatingpid | |
Moduline 400 | thermostat | 78 | preheating | preheating in the clock program | boolean | True | switch.thermostat_preheating_in_the_clock_program | switch.thermostat_preheating | |
Moduline 400 | thermostat | 78 | intoffset | internal temperature offset | int8 (>=-12<=12) | C | True | number.thermostat_internal_temperature_offset | number.thermostat_intoffset |
Moduline 400 | thermostat | 78 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp |
Moduline 400 | thermostat | 78 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp |
Moduline 400 | thermostat | 78 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | |
Moduline 400 | thermostat | 78 | mode | mode | enum [off|manual|auto] | True | select.thermostat_hc1_mode | select.thermostat_hc1_mode | |
Moduline 400 | thermostat | 78 | holidays | holiday dates | string | True | sensor.thermostat_hc1_holiday_dates | sensor.thermostat_hc1_holidays | |
Moduline 400 | thermostat | 78 | vacations | vacation dates | string | True | sensor.thermostat_hc1_vacation_dates | sensor.thermostat_hc1_vacations | |
Moduline 400 | thermostat | 78 | program | program | enum [own 1|family|morning|evening|am|pm|midday|singles|seniors|new|own 2] | True | select.thermostat_hc1_program | select.thermostat_hc1_program | |
Moduline 400 | thermostat | 78 | pause | pause time | uint8 (>=0<=254) | hours | True | number.thermostat_hc1_pause_time | number.thermostat_hc1_pause |
Moduline 400 | thermostat | 78 | party | party time | uint8 (>=0<=254) | hours | True | number.thermostat_hc1_party_time | number.thermostat_hc1_party |
Moduline 400 | thermostat | 78 | switchtime1 | own1 program switchtime | string | True | sensor.thermostat_hc1_own1_program_switchtime | sensor.thermostat_hc1_switchtime1 | |
Moduline 400 | thermostat | 78 | heatingtype | heating type | enum [off|radiator|convector|floor] | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | |
Moduline 400 | thermostat | 78 | controlmode | control mode | enum [outdoor|room] | True | select.thermostat_hc1_control_mode | select.thermostat_hc1_controlmode | |
Moduline 400 | thermostat | 78 | holidaytemp | holiday temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_holiday_temperature | number.thermostat_hc1_holidaytemp |
Moduline 400 | thermostat | 78 | nighttemp | night temperature T1 | uint8 (>=0<=127) | C | True | number.thermostat_hc1_night_temperature_T1 | number.thermostat_hc1_nighttemp |
Moduline 400 | thermostat | 78 | daytemp2 | day temperature T2 | uint8 (>=0<=127) | C | True | number.thermostat_hc1_day_temperature_T2 | number.thermostat_hc1_daytemp2 |
Moduline 400 | thermostat | 78 | daytemp3 | day temperature T3 | uint8 (>=0<=127) | C | True | number.thermostat_hc1_day_temperature_T3 | number.thermostat_hc1_daytemp3 |
Moduline 400 | thermostat | 78 | daytemp4 | day temperature T4 | uint8 (>=0<=127) | C | True | number.thermostat_hc1_day_temperature_T4 | number.thermostat_hc1_daytemp4 |
Moduline 400 | thermostat | 78 | manualtemp | manual temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_manual_temperature | number.thermostat_hc1_manualtemp |
Moduline 400 | thermostat | 78 | offtemp | temperature when mode is off | uint8 (>=0<=127) | C | True | number.thermostat_hc1_temperature_when_mode_is_off | number.thermostat_hc1_offtemp |
Moduline 400 | thermostat | 78 | mode | mode | enum [on|off|auto] | True | select.thermostat_dhw_mode | select.thermostat_dhw_mode | |
Moduline 400 | thermostat | 78 | whenmodeoff | when thermostat mode off | boolean | True | switch.thermostat_dhw_when_thermostat_mode_off | switch.thermostat_dhw_whenmodeoff | |
Moduline 400 | thermostat | 78 | disinfecting | disinfecting | boolean | True | switch.thermostat_dhw_disinfecting | switch.thermostat_dhw_disinfecting | |
Moduline 400 | thermostat | 78 | disinfectday | disinfection day | enum [mo|tu|we|th|fr|sa|su|all] | True | select.thermostat_dhw_disinfection_day | select.thermostat_dhw_disinfectday | |
Moduline 400 | thermostat | 78 | disinfecthour | disinfection hour | uint8 (>=0<=23) | True | number.thermostat_dhw_disinfection_hour | number.thermostat_dhw_disinfecthour | |
Moduline 400 | thermostat | 78 | holidays | holiday dates | string | True | sensor.thermostat_dhw_holiday_dates | sensor.thermostat_dhw_holidays | |
Moduline 400 | thermostat | 78 | vacations | vacation dates | string | True | sensor.thermostat_dhw_vacation_dates | sensor.thermostat_dhw_vacations | |
RC10/Moduline 100 | thermostat | 79 | errorcode | error code | string | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | |
RC10/Moduline 100 | thermostat | 79 | lastcode | last error code | string | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | |
RC10/Moduline 100 | thermostat | 79 | intoffset | internal temperature offset | int8 (>=-12<=12) | C | True | number.thermostat_internal_temperature_offset | number.thermostat_intoffset |
RC10/Moduline 100 | thermostat | 79 | heatingpid | heating PID | enum [fast|medium|slow] | True | select.thermostat_heating_PID | select.thermostat_heatingpid | |
RC10/Moduline 100 | thermostat | 79 | backlight | key backlight | boolean | True | switch.thermostat_key_backlight | switch.thermostat_backlight | |
RC10/Moduline 100 | thermostat | 79 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp |
RC10/Moduline 100 | thermostat | 79 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp |
RC10/Moduline 100 | thermostat | 79 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | |
RC10/Moduline 100 | thermostat | 79 | mode | mode | enum [nofrost|night|day] | True | select.thermostat_hc1_mode | select.thermostat_hc1_mode | |
RC10/Moduline 100 | thermostat | 79 | daytemp | day temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_day_temperature | number.thermostat_hc1_daytemp |
RC10/Moduline 100 | thermostat | 79 | nighttemp | night temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_night_temperature | number.thermostat_hc1_nighttemp |
RC10/Moduline 100 | thermostat | 79 | reducehours | duration for nighttemp | uint8 (>=0<=254) | hours | True | number.thermostat_hc1_duration_for_nighttemp | number.thermostat_hc1_reducehours |
RC10/Moduline 100 | thermostat | 79 | reduceminutes | remaining time for nightmode | uint16 (>=0<=31999) | minutes | False | sensor.thermostat_hc1_remaining_time_for_nightmode | sensor.thermostat_hc1_reduceminutes |
RC10/Moduline 100 | thermostat | 79 | mode | mode | enum [on|off|auto] | True | select.thermostat_dhw_mode | select.thermostat_dhw_mode | |
Moduline 200 | thermostat | 80 | errorcode | error code | string | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | |
Moduline 200 | thermostat | 80 | lastcode | last error code | string | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | |
Moduline 200 | thermostat | 80 | intoffset | internal temperature offset | int8 (>=-12<=12) | C | True | number.thermostat_internal_temperature_offset | number.thermostat_intoffset |
Moduline 200 | thermostat | 80 | heatingpid | heating PID | enum [fast|medium|slow] | True | select.thermostat_heating_PID | select.thermostat_heatingpid | |
Moduline 200 | thermostat | 80 | backlight | key backlight | boolean | True | switch.thermostat_key_backlight | switch.thermostat_backlight | |
Moduline 200 | thermostat | 80 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp |
Moduline 200 | thermostat | 80 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp |
Moduline 200 | thermostat | 80 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | |
Moduline 200 | thermostat | 80 | mode | mode | enum [nofrost|night|day] | True | select.thermostat_hc1_mode | select.thermostat_hc1_mode | |
Moduline 200 | thermostat | 80 | daytemp | day temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_day_temperature | number.thermostat_hc1_daytemp |
Moduline 200 | thermostat | 80 | nighttemp | night temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_night_temperature | number.thermostat_hc1_nighttemp |
Moduline 200 | thermostat | 80 | reducehours | duration for nighttemp | uint8 (>=0<=254) | hours | True | number.thermostat_hc1_duration_for_nighttemp | number.thermostat_hc1_reducehours |
Moduline 200 | thermostat | 80 | reduceminutes | remaining time for nightmode | uint16 (>=0<=31999) | minutes | False | sensor.thermostat_hc1_remaining_time_for_nightmode | sensor.thermostat_hc1_reduceminutes |
Moduline 200 | thermostat | 80 | mode | mode | enum [on|off|auto] | True | select.thermostat_dhw_mode | select.thermostat_dhw_mode | |
RC35 | thermostat | 86 | errorcode | error code | string | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | |
RC35 | thermostat | 86 | lastcode | last error code | string | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | |
RC35 | thermostat | 86 | datetime | date/time | string | True | sensor.thermostat_date/time | sensor.thermostat_datetime | |
RC35 | thermostat | 86 | intoffset | internal temperature offset | int8 (>=-5<=5) | C | True | number.thermostat_internal_temperature_offset | number.thermostat_intoffset |
RC35 | thermostat | 86 | minexttemp | minimal external temperature | int8 (>=-30<=0) | C | True | number.thermostat_minimal_external_temperature | number.thermostat_minexttemp |
RC35 | thermostat | 86 | inttemp1 | temperature sensor 1 | int16 (>=-3199<=3199) | C | False | sensor.thermostat_temperature_sensor_1 | sensor.thermostat_inttemp1 |
RC35 | thermostat | 86 | inttemp2 | temperature sensor 2 | int16 (>=-3199<=3199) | C | False | sensor.thermostat_temperature_sensor_2 | sensor.thermostat_inttemp2 |
RC35 | thermostat | 86 | damping | damping outdoor temperature | boolean | True | switch.thermostat_damping_outdoor_temperature | switch.thermostat_damping | |
RC35 | thermostat | 86 | dampedoutdoortemp | damped outdoor temperature | int8 (>=-126<=126) | C | False | sensor.thermostat_damped_outdoor_temperature | sensor.thermostat_dampedoutdoortemp |
RC35 | thermostat | 86 | building | building type | enum [light|medium|heavy] | True | select.thermostat_building_type | select.thermostat_building | |
RC35 | thermostat | 86 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp |
RC35 | thermostat | 86 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp |
RC35 | thermostat | 86 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | |
RC35 | thermostat | 86 | mode | mode | enum [night|day|auto] | True | select.thermostat_hc1_mode | select.thermostat_hc1_mode | |
RC35 | thermostat | 86 | modetype | mode type | enum [night|day] | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | |
RC35 | thermostat | 86 | daytemp | day temperature | uint8 (>=10<=30) | C | True | number.thermostat_hc1_day_temperature | number.thermostat_hc1_daytemp |
RC35 | thermostat | 86 | nighttemp | night temperature | uint8 (>=10<=30) | C | True | number.thermostat_hc1_night_temperature | number.thermostat_hc1_nighttemp |
RC35 | thermostat | 86 | designtemp | design temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_design_temperature | number.thermostat_hc1_designtemp |
RC35 | thermostat | 86 | offsettemp | offset temperature | int8 (>=-5<=5) | C | True | number.thermostat_hc1_offset_temperature | number.thermostat_hc1_offsettemp |
RC35 | thermostat | 86 | holidaytemp | holiday temperature | uint8 (>=5<=30) | C | True | number.thermostat_hc1_holiday_temperature | number.thermostat_hc1_holidaytemp |
RC35 | thermostat | 86 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp |
RC35 | thermostat | 86 | summertemp | summer temperature | uint8 (>=9<=25) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp |
RC35 | thermostat | 86 | summermode | summer mode | enum [winter|summer] | False | sensor.thermostat_hc1_summer_mode | sensor.thermostat_hc1_summermode | |
RC35 | thermostat | 86 | holidaymode | holiday mode | boolean | False | binary_sensor.thermostat_hc1_holiday_mode | binary_sensor.thermostat_hc1_holidaymode | |
RC35 | thermostat | 86 | nofrosttemp | nofrost temperature | int8 (>=-20<=10) | C | True | number.thermostat_hc1_nofrost_temperature | number.thermostat_hc1_nofrosttemp |
RC35 | thermostat | 86 | nofrostmode | nofrost mode | enum [off|outdoor|room] | True | select.thermostat_hc1_nofrost_mode | select.thermostat_hc1_nofrostmode | |
RC35 | thermostat | 86 | roominfluence | room influence | uint8 (>=0<=10) | C | True | number.thermostat_hc1_room_influence | number.thermostat_hc1_roominfluence |
RC35 | thermostat | 86 | minflowtemp | min flow temperature | uint8 (>=5<=70) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp |
RC35 | thermostat | 86 | maxflowtemp | max flow temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp |
RC35 | thermostat | 86 | flowtempoffset | flow temperature offset for mixer | uint8 (>=0<=20) | C | True | number.thermostat_hc1_flow_temperature_offset_for_mixer | number.thermostat_hc1_flowtempoffset |
RC35 | thermostat | 86 | heatingtype | heating type | enum [off|radiator|convector|floor] | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | |
RC35 | thermostat | 86 | reducemode | reduce mode | enum [nofrost|reduce|room|outdoor] | True | select.thermostat_hc1_reduce_mode | select.thermostat_hc1_reducemode | |
RC35 | thermostat | 86 | controlmode | control mode | enum [outdoor|room] | True | select.thermostat_hc1_control_mode | select.thermostat_hc1_controlmode | |
RC35 | thermostat | 86 | control | control device | enum [off|RC20|RC3x] | True | select.thermostat_hc1_control_device | select.thermostat_hc1_control | |
RC35 | thermostat | 86 | holidays | holiday dates | string | True | sensor.thermostat_hc1_holiday_dates | sensor.thermostat_hc1_holidays | |
RC35 | thermostat | 86 | vacations | vacation dates | string | True | sensor.thermostat_hc1_vacation_dates | sensor.thermostat_hc1_vacations | |
RC35 | thermostat | 86 | program | program | enum [own 1|family|morning|evening|am|pm|midday|singles|seniors|new|own 2] | True | select.thermostat_hc1_program | select.thermostat_hc1_program | |
RC35 | thermostat | 86 | pause | pause time | uint8 (>=0<=99) | hours | True | number.thermostat_hc1_pause_time | number.thermostat_hc1_pause |
RC35 | thermostat | 86 | party | party time | uint8 (>=0<=99) | hours | True | number.thermostat_hc1_party_time | number.thermostat_hc1_party |
RC35 | thermostat | 86 | tempautotemp | temporary set temperature automode | uint8 (>=0<=30) | C | True | number.thermostat_hc1_temporary_set_temperature_automode | number.thermostat_hc1_tempautotemp |
RC35 | thermostat | 86 | noreducetemp | no reduce below temperature | int8 (>=-31<=10) | C | True | number.thermostat_hc1_no_reduce_below_temperature | number.thermostat_hc1_noreducetemp |
RC35 | thermostat | 86 | reducetemp | off/reduce switch temperature | int8 (>=-20<=10) | C | True | number.thermostat_hc1_off/reduce_switch_temperature | number.thermostat_hc1_reducetemp |
RC35 | thermostat | 86 | vacreducetemp | vacations off/reduce switch temperature | int8 (>=-20<=10) | C | True | number.thermostat_hc1_vacations_off/reduce_switch_temperature | number.thermostat_hc1_vacreducetemp |
RC35 | thermostat | 86 | vacreducemode | vacations reduce mode | enum [nofrost|reduce|room|outdoor] | True | select.thermostat_hc1_vacations_reduce_mode | select.thermostat_hc1_vacreducemode | |
RC35 | thermostat | 86 | remotetemp | room temperature from remote | int16 (>=-1<=101) | C | True | number.thermostat_hc1_room_temperature_from_remote | number.thermostat_hc1_remotetemp |
RC35 | thermostat | 86 | dhwprio | dhw priority | boolean | True | switch.thermostat_hc1_dhw_priority | switch.thermostat_hc1_dhwprio | |
RC35 | thermostat | 86 | switchonoptimization | switch-on optimization | boolean | True | switch.thermostat_hc1_switch-on_optimization | switch.thermostat_hc1_switchonoptimization | |
RC35 | thermostat | 86 | switchtime1 | own1 program switchtime | string | True | sensor.thermostat_hc1_own1_program_switchtime | sensor.thermostat_hc1_switchtime1 | |
RC35 | thermostat | 86 | switchtime2 | own2 program switchtime | string | True | sensor.thermostat_hc1_own2_program_switchtime | sensor.thermostat_hc1_switchtime2 | |
RC35 | thermostat | 86 | mode | mode | enum [off|on|auto] | True | select.thermostat_dhw_mode | select.thermostat_dhw_mode | |
RC35 | thermostat | 86 | circmode | circulation pump mode | enum [off|on|auto] | True | select.thermostat_dhw_circulation_pump_mode | select.thermostat_dhw_circmode | |
RC35 | thermostat | 86 | progmode | program | enum [std prog|own prog] | True | select.thermostat_dhw_program | select.thermostat_dhw_progmode | |
RC35 | thermostat | 86 | circprog | circulation program | enum [std prog|own prog] | True | select.thermostat_dhw_circulation_program | select.thermostat_dhw_circprog | |
RC35 | thermostat | 86 | disinfecting | disinfecting | boolean | True | switch.thermostat_dhw_disinfecting | switch.thermostat_dhw_disinfecting | |
RC35 | thermostat | 86 | disinfectday | disinfection day | enum [mo|tu|we|th|fr|sa|su|all] | True | select.thermostat_dhw_disinfection_day | select.thermostat_dhw_disinfectday | |
RC35 | thermostat | 86 | disinfecthour | disinfection hour | uint8 (>=0<=23) | True | number.thermostat_dhw_disinfection_hour | number.thermostat_dhw_disinfecthour | |
RC35 | thermostat | 86 | maxtemp | maximum temperature | uint8 (>=60<=80) | C | True | number.thermostat_dhw_maximum_temperature | number.thermostat_dhw_maxtemp |
RC35 | thermostat | 86 | onetimekey | one time key function | boolean | True | switch.thermostat_dhw_one_time_key_function | switch.thermostat_dhw_onetimekey | |
RC35 | thermostat | 86 | switchtime | program switchtime | string | True | sensor.thermostat_dhw_program_switchtime | sensor.thermostat_dhw_switchtime | |
RC35 | thermostat | 86 | circswitchtime | circulation program switchtime | string | True | sensor.thermostat_dhw_circulation_program_switchtime | sensor.thermostat_dhw_circswitchtime | |
RC35 | thermostat | 86 | holidays | holiday dates | string | True | sensor.thermostat_dhw_holiday_dates | sensor.thermostat_dhw_holidays | |
RC35 | thermostat | 86 | vacations | vacation dates | string | True | sensor.thermostat_dhw_vacation_dates | sensor.thermostat_dhw_vacations | |
RC10/Moduline 100 | thermostat | 90 | errorcode | error code | string | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | |
RC10/Moduline 100 | thermostat | 90 | lastcode | last error code | string | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | |
RC10/Moduline 100 | thermostat | 90 | datetime | date/time | string | False | sensor.thermostat_date/time | sensor.thermostat_datetime | |
RC10/Moduline 100 | thermostat | 90 | minexttemp | minimal external temperature | int8 (>=-126<=126) | C | True | number.thermostat_minimal_external_temperature | number.thermostat_minexttemp |
RC10/Moduline 100 | thermostat | 90 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp |
RC10/Moduline 100 | thermostat | 90 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp |
RC10/Moduline 100 | thermostat | 90 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | |
RC10/Moduline 100 | thermostat | 90 | mode | mode | enum [night|day|auto] | True | select.thermostat_hc1_mode | select.thermostat_hc1_mode | |
RC10/Moduline 100 | thermostat | 90 | modetype | mode type | enum [night|day] | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | |
RC10/Moduline 100 | thermostat | 90 | daytemp | day temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_day_temperature | number.thermostat_hc1_daytemp |
RC10/Moduline 100 | thermostat | 90 | nighttemp | night temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_night_temperature | number.thermostat_hc1_nighttemp |
RC10/Moduline 100 | thermostat | 90 | program | program | enum [family|morning|evening|am|pm|midday|singles|seniors] | True | select.thermostat_hc1_program | select.thermostat_hc1_program | |
RC10/Moduline 100 | thermostat | 90 | minflowtemp | min flow temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp |
RC10/Moduline 100 | thermostat | 90 | maxflowtemp | max flow temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp |
RC10/Moduline 100 | thermostat | 90 | tempautotemp | temporary set temperature automode | uint8 (>=0<=127) | C | True | number.thermostat_hc1_temporary_set_temperature_automode | number.thermostat_hc1_tempautotemp |
RC10/Moduline 100 | thermostat | 90 | heatingtype | heating type | enum [off|radiator|convector|floor] | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | |
RC10/Moduline 100 | thermostat | 90 | summertemp | summer temperature | uint8 (>=10<=30) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp |
RC10/Moduline 100 | thermostat | 90 | summermode | summer mode | enum [winter|summer] | False | sensor.thermostat_hc1_summer_mode | sensor.thermostat_hc1_summermode | |
RC10/Moduline 100 | thermostat | 90 | remotetemp | room temperature from remote | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_room_temperature_from_remote | sensor.thermostat_hc1_remotetemp |
RC20RF | thermostat | 93 | errorcode | error code | string | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | |
RC20RF | thermostat | 93 | lastcode | last error code | string | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | |
RC20RF | thermostat | 93 | datetime | date/time | string | False | sensor.thermostat_date/time | sensor.thermostat_datetime | |
RC20RF | thermostat | 93 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp |
RC20RF | thermostat | 93 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp |
RC20RF | thermostat | 93 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | |
RC20RF | thermostat | 93 | mode | mode | enum [off|manual|auto] | True | select.thermostat_hc1_mode | select.thermostat_hc1_mode | |
RC20RF | thermostat | 93 | manualtemp | manual temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_manual_temperature | number.thermostat_hc1_manualtemp |
RC20RF | thermostat | 93 | offtemp | temperature when mode is off | uint8 (>=0<=127) | C | True | number.thermostat_hc1_temperature_when_mode_is_off | number.thermostat_hc1_offtemp |
RC20RF | thermostat | 93 | daytemp2 | day temperature T2 | uint8 (>=0<=127) | C | True | number.thermostat_hc1_day_temperature_T2 | number.thermostat_hc1_daytemp2 |
RC20RF | thermostat | 93 | daytemp3 | day temperature T3 | uint8 (>=0<=127) | C | True | number.thermostat_hc1_day_temperature_T3 | number.thermostat_hc1_daytemp3 |
RC20RF | thermostat | 93 | daytemp4 | day temperature T4 | uint8 (>=0<=127) | C | True | number.thermostat_hc1_day_temperature_T4 | number.thermostat_hc1_daytemp4 |
RC20RF | thermostat | 93 | nighttemp | night temperature T1 | uint8 (>=0<=127) | C | True | number.thermostat_hc1_night_temperature_T1 | number.thermostat_hc1_nighttemp |
RC20RF | thermostat | 93 | switchtime | program switchtime | string | True | sensor.thermostat_hc1_program_switchtime | sensor.thermostat_hc1_switchtime | |
RFM20 Remote | thermostat | 94 | errorcode | error code | string | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | |
RFM20 Remote | thermostat | 94 | lastcode | last error code | string | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | |
RFM20 Remote | thermostat | 94 | datetime | date/time | string | False | sensor.thermostat_date/time | sensor.thermostat_datetime | |
RFM20 Remote | thermostat | 94 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp |
RFM20 Remote | thermostat | 94 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp |
RFM20 Remote | thermostat | 94 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | |
RC25 | thermostat | 151 | errorcode | error code | string | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | |
RC25 | thermostat | 151 | lastcode | last error code | string | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | |
RC25 | thermostat | 151 | datetime | date/time | string | False | sensor.thermostat_date/time | sensor.thermostat_datetime | |
RC25 | thermostat | 151 | minexttemp | minimal external temperature | int8 (>=-126<=126) | C | True | number.thermostat_minimal_external_temperature | number.thermostat_minexttemp |
RC25 | thermostat | 151 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp |
RC25 | thermostat | 151 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp |
RC25 | thermostat | 151 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | |
RC25 | thermostat | 151 | mode | mode | enum [night|day|auto] | True | select.thermostat_hc1_mode | select.thermostat_hc1_mode | |
RC25 | thermostat | 151 | modetype | mode type | enum [night|day] | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | |
RC25 | thermostat | 151 | daytemp | day temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_day_temperature | number.thermostat_hc1_daytemp |
RC25 | thermostat | 151 | nighttemp | night temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_night_temperature | number.thermostat_hc1_nighttemp |
RC25 | thermostat | 151 | program | program | enum [family|morning|evening|am|pm|midday|singles|seniors] | True | select.thermostat_hc1_program | select.thermostat_hc1_program | |
RC25 | thermostat | 151 | minflowtemp | min flow temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp |
RC25 | thermostat | 151 | maxflowtemp | max flow temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp |
RC25 | thermostat | 151 | tempautotemp | temporary set temperature automode | uint8 (>=0<=127) | C | True | number.thermostat_hc1_temporary_set_temperature_automode | number.thermostat_hc1_tempautotemp |
RC25 | thermostat | 151 | heatingtype | heating type | enum [off|radiator|convector|floor] | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | |
RC25 | thermostat | 151 | summertemp | summer temperature | uint8 (>=9<=25) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp |
RC25 | thermostat | 151 | summermode | summer mode | enum [winter|summer] | False | sensor.thermostat_hc1_summer_mode | sensor.thermostat_hc1_summermode | |
RC200/CW100 | thermostat | 157 | errorcode | error code | string | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | |
RC200/CW100 | thermostat | 157 | lastcode | last error code | string | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | |
RC200/CW100 | thermostat | 157 | datetime | date/time | string | True | sensor.thermostat_date/time | sensor.thermostat_datetime | |
RC200/CW100 | thermostat | 157 | intoffset | internal temperature offset | int8 (>=-12<=12) | C | True | number.thermostat_internal_temperature_offset | number.thermostat_intoffset |
RC200/CW100 | thermostat | 157 | floordry | floor drying | enum [off|start|heat|hold|cool|end] | False | sensor.thermostat_floor_drying | sensor.thermostat_floordry | |
RC200/CW100 | thermostat | 157 | dampedoutdoortemp | damped outdoor temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_damped_outdoor_temperature | sensor.thermostat_dampedoutdoortemp |
RC200/CW100 | thermostat | 157 | floordrytemp | floor drying temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_floor_drying_temperature | sensor.thermostat_floordrytemp |
RC200/CW100 | thermostat | 157 | building | building type | enum [light|medium|heavy] | True | select.thermostat_building_type | select.thermostat_building | |
RC200/CW100 | thermostat | 157 | minexttemp | minimal external temperature | int8 (>=-126<=126) | C | True | number.thermostat_minimal_external_temperature | number.thermostat_minexttemp |
RC200/CW100 | thermostat | 157 | damping | damping outdoor temperature | boolean | True | switch.thermostat_damping_outdoor_temperature | switch.thermostat_damping | |
RC200/CW100 | thermostat | 157 | hybridstrategy | hybrid control strategy | enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] | True | select.thermostat_hybrid_control_strategy | select.thermostat_hybridstrategy | |
RC200/CW100 | thermostat | 157 | switchovertemp | outside switchover temperature | int8 (>=-20<=20) | C | True | number.thermostat_outside_switchover_temperature | number.thermostat_switchovertemp |
RC200/CW100 | thermostat | 157 | energycostratio | energy cost ratio | uint8 (>=0<=20) | True | number.thermostat_energy_cost_ratio | number.thermostat_energycostratio | |
RC200/CW100 | thermostat | 157 | fossilefactor | fossile energy factor | uint8 (>=0<=5) | True | number.thermostat_fossile_energy_factor | number.thermostat_fossilefactor | |
RC200/CW100 | thermostat | 157 | electricfactor | electric energy factor | uint8 (>=0<=5) | True | number.thermostat_electric_energy_factor | number.thermostat_electricfactor | |
RC200/CW100 | thermostat | 157 | delayboiler | delay boiler support | uint8 (>=5<=120) | minutes | True | number.thermostat_delay_boiler_support | number.thermostat_delayboiler |
RC200/CW100 | thermostat | 157 | tempdiffboiler | temp diff boiler support | uint8 (>=1<=99) | C | True | number.thermostat_temp_diff_boiler_support | number.thermostat_tempdiffboiler |
RC200/CW100 | thermostat | 157 | pvenabledhw | enable raise dhw | boolean | True | switch.thermostat_enable_raise_dhw | switch.thermostat_pvenabledhw | |
RC200/CW100 | thermostat | 157 | pvraiseheat | raise heating with PV | int8 (>=0<=5) | K | True | number.thermostat_raise_heating_with_PV | number.thermostat_pvraiseheat |
RC200/CW100 | thermostat | 157 | pvlowercool | lower cooling with PV | int8 (>=-5<=0) | K | True | number.thermostat_lower_cooling_with_PV | number.thermostat_pvlowercool |
RC200/CW100 | thermostat | 157 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp |
RC200/CW100 | thermostat | 157 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp |
RC200/CW100 | thermostat | 157 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | |
RC200/CW100 | thermostat | 157 | mode | mode | enum [manual|auto] | True | select.thermostat_hc1_mode | select.thermostat_hc1_mode | |
RC200/CW100 | thermostat | 157 | modetype | mode type | enum [eco|comfort] | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | |
RC200/CW100 | thermostat | 157 | ecotemp | eco temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_eco_temperature | number.thermostat_hc1_ecotemp |
RC200/CW100 | thermostat | 157 | manualtemp | manual temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_manual_temperature | number.thermostat_hc1_manualtemp |
RC200/CW100 | thermostat | 157 | comforttemp | comfort temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_comfort_temperature | number.thermostat_hc1_comforttemp |
RC200/CW100 | thermostat | 157 | summertemp | summer temperature | uint8 (>=10<=30) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp |
RC200/CW100 | thermostat | 157 | designtemp | design temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_design_temperature | number.thermostat_hc1_designtemp |
RC200/CW100 | thermostat | 157 | offsettemp | offset temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_offset_temperature | number.thermostat_hc1_offsettemp |
RC200/CW100 | thermostat | 157 | minflowtemp | min flow temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp |
RC200/CW100 | thermostat | 157 | maxflowtemp | max flow temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp |
RC200/CW100 | thermostat | 157 | roominfluence | room influence | uint8 (>=0<=254) | C | True | number.thermostat_hc1_room_influence | number.thermostat_hc1_roominfluence |
RC200/CW100 | thermostat | 157 | roominflfactor | room influence factor | uint8 (>=0<=25) | True | number.thermostat_hc1_room_influence_factor | number.thermostat_hc1_roominflfactor | |
RC200/CW100 | thermostat | 157 | curroominfl | current room influence | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_influence | sensor.thermostat_hc1_curroominfl |
RC200/CW100 | thermostat | 157 | nofrostmode | nofrost mode | enum [room|outdoor|room outdoor] | True | select.thermostat_hc1_nofrost_mode | select.thermostat_hc1_nofrostmode | |
RC200/CW100 | thermostat | 157 | nofrosttemp | nofrost temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_nofrost_temperature | number.thermostat_hc1_nofrosttemp |
RC200/CW100 | thermostat | 157 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp |
RC200/CW100 | thermostat | 157 | heatingtype | heating type | enum [off|radiator|convector|floor] | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | |
RC200/CW100 | thermostat | 157 | summersetmode | set summer mode | enum [summer|auto|winter] | True | select.thermostat_hc1_set_summer_mode | select.thermostat_hc1_summersetmode | |
RC200/CW100 | thermostat | 157 | hpoperatingmode | heatpump operating mode | enum [off|auto|heating|cooling] | True | select.thermostat_hc1_heatpump_operating_mode | select.thermostat_hc1_hpoperatingmode | |
RC200/CW100 | thermostat | 157 | summermode | summer mode | enum [winter|summer] | False | sensor.thermostat_hc1_summer_mode | sensor.thermostat_hc1_summermode | |
RC200/CW100 | thermostat | 157 | hpoperatingstate | heatpump operating state | enum [heating|off|cooling] | False | sensor.thermostat_hc1_heatpump_operating_state | sensor.thermostat_hc1_hpoperatingstate | |
RC200/CW100 | thermostat | 157 | controlmode | control mode | enum [optimized|simple|n/a|room|power] | True | select.thermostat_hc1_control_mode | select.thermostat_hc1_controlmode | |
RC200/CW100 | thermostat | 157 | program | program | enum [prog 1|prog 2] | True | select.thermostat_hc1_program | select.thermostat_hc1_program | |
RC200/CW100 | thermostat | 157 | tempautotemp | temporary set temperature automode | int8 (>=-1<=30) | C | True | number.thermostat_hc1_temporary_set_temperature_automode | number.thermostat_hc1_tempautotemp |
RC200/CW100 | thermostat | 157 | remoteseltemp | temporary set temperature from remote | int8 (>=-63<=63) | C | False | sensor.thermostat_hc1_temporary_set_temperature_from_remote | sensor.thermostat_hc1_remoteseltemp |
RC200/CW100 | thermostat | 157 | fastheatup | fast heatup | uint8 (>=0<=100) | % | True | number.thermostat_hc1_fast_heatup | number.thermostat_hc1_fastheatup |
RC200/CW100 | thermostat | 157 | switchonoptimization | switch-on optimization | boolean | True | switch.thermostat_hc1_switch-on_optimization | switch.thermostat_hc1_switchonoptimization | |
RC200/CW100 | thermostat | 157 | reducemode | reduce mode | enum [outdoor|room|reduce] | True | select.thermostat_hc1_reduce_mode | select.thermostat_hc1_reducemode | |
RC200/CW100 | thermostat | 157 | noreducetemp | no reduce below temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_no_reduce_below_temperature | number.thermostat_hc1_noreducetemp |
RC200/CW100 | thermostat | 157 | reducetemp | off/reduce switch temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_off/reduce_switch_temperature | number.thermostat_hc1_reducetemp |
RC200/CW100 | thermostat | 157 | dhwprio | dhw priority | boolean | True | switch.thermostat_hc1_dhw_priority | switch.thermostat_hc1_dhwprio | |
RC200/CW100 | thermostat | 157 | cooling | cooling | boolean | True | switch.thermostat_hc1_cooling | switch.thermostat_hc1_cooling | |
RC200/CW100 | thermostat | 157 | coolingon | cooling | boolean | False | binary_sensor.thermostat_hc1_cooling | binary_sensor.thermostat_hc1_coolingon | |
RC200/CW100 | thermostat | 157 | hpmode | HP Mode | enum [heating|cooling|heating&cooling] | True | select.thermostat_hc1_HP_Mode | select.thermostat_hc1_hpmode | |
RC200/CW100 | thermostat | 157 | dewoffset | dew point offset | uint8 (>=2<=10) | K | True | number.thermostat_hc1_dew_point_offset | number.thermostat_hc1_dewoffset |
RC200/CW100 | thermostat | 157 | roomtempdiff | room temp difference | uint8 (>=0<=254) | K | True | number.thermostat_hc1_room_temp_difference | number.thermostat_hc1_roomtempdiff |
RC200/CW100 | thermostat | 157 | hpminflowtemp | HP min. flow temp. | uint8 (>=0<=254) | C | True | number.thermostat_hc1_HP_min._flow_temp. | number.thermostat_hc1_hpminflowtemp |
RC200/CW100 | thermostat | 157 | control | control device | enum [RC310|RC200|RC100|RC100H|TC100] | True | select.thermostat_hc1_control_device | select.thermostat_hc1_control | |
RC200/CW100 | thermostat | 157 | remotetemp | room temperature from remote | int16 (>=-1<=101) | C | True | number.thermostat_hc1_room_temperature_from_remote | number.thermostat_hc1_remotetemp |
RC200/CW100 | thermostat | 157 | remotehum | room humidity from remote | uint8 (>=-1<=101) | % | True | number.thermostat_hc1_room_humidity_from_remote | number.thermostat_hc1_remotehum |
RC200/CW100 | thermostat | 157 | heatondelay | heat-on delay | uint8 (>=1<=48) | hours | True | number.thermostat_hc1_heat-on_delay | number.thermostat_hc1_heatondelay |
RC200/CW100 | thermostat | 157 | heatoffdelay | heat-off delay | uint8 (>=1<=48) | hours | True | number.thermostat_hc1_heat-off_delay | number.thermostat_hc1_heatoffdelay |
RC200/CW100 | thermostat | 157 | instantstart | instant start | uint8 (>=1<=10) | K | True | number.thermostat_hc1_instant_start | number.thermostat_hc1_instantstart |
RC200/CW100 | thermostat | 157 | boost | boost mode | boolean | True | switch.thermostat_hc1_boost_mode | switch.thermostat_hc1_boost | |
RC200/CW100 | thermostat | 157 | boosttime | boost time | uint8 (>=0<=254) | hours | True | number.thermostat_hc1_boost_time | number.thermostat_hc1_boosttime |
RC200/CW100 | thermostat | 157 | mode | mode | enum [off|normal|comfort|auto|own prog] | True | select.thermostat_dhw_mode | select.thermostat_dhw_mode | |
RC200/CW100 | thermostat | 157 | settemp | set temperature | uint8 (>=0<=254) | C | True | number.thermostat_dhw_set_temperature | number.thermostat_dhw_settemp |
RC200/CW100 | thermostat | 157 | settemplow | set low temperature | uint8 (>=0<=254) | C | True | number.thermostat_dhw_set_low_temperature | number.thermostat_dhw_settemplow |
RC200/CW100 | thermostat | 157 | circmode | circulation pump mode | enum [off|on|auto|own prog] | True | select.thermostat_dhw_circulation_pump_mode | select.thermostat_dhw_circmode | |
RC200/CW100 | thermostat | 157 | chargeduration | charge duration | uint8 (>=0<=3810) | minutes | True | number.thermostat_dhw_charge_duration | number.thermostat_dhw_chargeduration |
RC200/CW100 | thermostat | 157 | charge | charge | boolean | True | switch.thermostat_dhw_charge | switch.thermostat_dhw_charge | |
RC200/CW100 | thermostat | 157 | extra | extra | uint8 (>=0<=254) | C | False | sensor.thermostat_dhw_extra | sensor.thermostat_dhw_extra |
RC200/CW100 | thermostat | 157 | disinfecting | disinfecting | boolean | True | switch.thermostat_dhw_disinfecting | switch.thermostat_dhw_disinfecting | |
RC200/CW100 | thermostat | 157 | disinfectday | disinfection day | enum [mo|tu|we|th|fr|sa|su|all] | True | select.thermostat_dhw_disinfection_day | select.thermostat_dhw_disinfectday | |
RC200/CW100 | thermostat | 157 | disinfecttime | disinfection time | uint8 (>=0<=1431) | minutes | True | number.thermostat_dhw_disinfection_time | number.thermostat_dhw_disinfecttime |
RC200/CW100 | thermostat | 157 | dailyheating | daily heating | boolean | True | switch.thermostat_dhw_daily_heating | switch.thermostat_dhw_dailyheating | |
RC200/CW100 | thermostat | 157 | dailyheattime | daily heating time | uint8 (>=0<=1431) | minutes | True | number.thermostat_dhw_daily_heating_time | number.thermostat_dhw_dailyheattime |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | errorcode | error code | string | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | lastcode | last error code | string | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | datetime | date/time | string | True | sensor.thermostat_date/time | sensor.thermostat_datetime | |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | intoffset | internal temperature offset | int8 (>=-12<=12) | C | True | number.thermostat_internal_temperature_offset | number.thermostat_intoffset |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | floordry | floor drying | enum [off|start|heat|hold|cool|end] | False | sensor.thermostat_floor_drying | sensor.thermostat_floordry | |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | dampedoutdoortemp | damped outdoor temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_damped_outdoor_temperature | sensor.thermostat_dampedoutdoortemp |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | floordrytemp | floor drying temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_floor_drying_temperature | sensor.thermostat_floordrytemp |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | building | building type | enum [light|medium|heavy] | True | select.thermostat_building_type | select.thermostat_building | |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | minexttemp | minimal external temperature | int8 (>=-126<=126) | C | True | number.thermostat_minimal_external_temperature | number.thermostat_minexttemp |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | damping | damping outdoor temperature | boolean | True | switch.thermostat_damping_outdoor_temperature | switch.thermostat_damping | |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | hybridstrategy | hybrid control strategy | enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] | True | select.thermostat_hybrid_control_strategy | select.thermostat_hybridstrategy | |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | switchovertemp | outside switchover temperature | int8 (>=-20<=20) | C | True | number.thermostat_outside_switchover_temperature | number.thermostat_switchovertemp |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | energycostratio | energy cost ratio | uint8 (>=0<=20) | True | number.thermostat_energy_cost_ratio | number.thermostat_energycostratio | |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | fossilefactor | fossile energy factor | uint8 (>=0<=5) | True | number.thermostat_fossile_energy_factor | number.thermostat_fossilefactor | |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | electricfactor | electric energy factor | uint8 (>=0<=5) | True | number.thermostat_electric_energy_factor | number.thermostat_electricfactor | |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | delayboiler | delay boiler support | uint8 (>=5<=120) | minutes | True | number.thermostat_delay_boiler_support | number.thermostat_delayboiler |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | tempdiffboiler | temp diff boiler support | uint8 (>=1<=99) | C | True | number.thermostat_temp_diff_boiler_support | number.thermostat_tempdiffboiler |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | pvenabledhw | enable raise dhw | boolean | True | switch.thermostat_enable_raise_dhw | switch.thermostat_pvenabledhw | |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | pvraiseheat | raise heating with PV | int8 (>=0<=5) | K | True | number.thermostat_raise_heating_with_PV | number.thermostat_pvraiseheat |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | pvlowercool | lower cooling with PV | int8 (>=-5<=0) | K | True | number.thermostat_lower_cooling_with_PV | number.thermostat_pvlowercool |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | mode | mode | enum [manual|auto] | True | select.thermostat_hc1_mode | select.thermostat_hc1_mode | |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | modetype | mode type | enum [eco|comfort] | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | ecotemp | eco temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_eco_temperature | number.thermostat_hc1_ecotemp |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | manualtemp | manual temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_manual_temperature | number.thermostat_hc1_manualtemp |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | comforttemp | comfort temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_comfort_temperature | number.thermostat_hc1_comforttemp |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | summertemp | summer temperature | uint8 (>=10<=30) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | designtemp | design temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_design_temperature | number.thermostat_hc1_designtemp |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | offsettemp | offset temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_offset_temperature | number.thermostat_hc1_offsettemp |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | minflowtemp | min flow temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | maxflowtemp | max flow temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | roominfluence | room influence | uint8 (>=0<=254) | C | True | number.thermostat_hc1_room_influence | number.thermostat_hc1_roominfluence |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | roominflfactor | room influence factor | uint8 (>=0<=25) | True | number.thermostat_hc1_room_influence_factor | number.thermostat_hc1_roominflfactor | |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | curroominfl | current room influence | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_influence | sensor.thermostat_hc1_curroominfl |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | nofrostmode | nofrost mode | enum [room|outdoor|room outdoor] | True | select.thermostat_hc1_nofrost_mode | select.thermostat_hc1_nofrostmode | |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | nofrosttemp | nofrost temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_nofrost_temperature | number.thermostat_hc1_nofrosttemp |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | heatingtype | heating type | enum [off|radiator|convector|floor] | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | summersetmode | set summer mode | enum [summer|auto|winter] | True | select.thermostat_hc1_set_summer_mode | select.thermostat_hc1_summersetmode | |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | hpoperatingmode | heatpump operating mode | enum [off|auto|heating|cooling] | True | select.thermostat_hc1_heatpump_operating_mode | select.thermostat_hc1_hpoperatingmode | |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | summermode | summer mode | enum [winter|summer] | False | sensor.thermostat_hc1_summer_mode | sensor.thermostat_hc1_summermode | |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | hpoperatingstate | heatpump operating state | enum [heating|off|cooling] | False | sensor.thermostat_hc1_heatpump_operating_state | sensor.thermostat_hc1_hpoperatingstate | |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | controlmode | control mode | enum [weather compensated|outside basepoint|n/a|room|power|constant] | True | select.thermostat_hc1_control_mode | select.thermostat_hc1_controlmode | |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | program | program | enum [prog 1|prog 2] | True | select.thermostat_hc1_program | select.thermostat_hc1_program | |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | tempautotemp | temporary set temperature automode | int8 (>=-1<=30) | C | True | number.thermostat_hc1_temporary_set_temperature_automode | number.thermostat_hc1_tempautotemp |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | remoteseltemp | temporary set temperature from remote | int8 (>=-63<=63) | C | False | sensor.thermostat_hc1_temporary_set_temperature_from_remote | sensor.thermostat_hc1_remoteseltemp |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | fastheatup | fast heatup | uint8 (>=0<=100) | % | True | number.thermostat_hc1_fast_heatup | number.thermostat_hc1_fastheatup |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | switchonoptimization | switch-on optimization | boolean | True | switch.thermostat_hc1_switch-on_optimization | switch.thermostat_hc1_switchonoptimization | |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | reducemode | reduce mode | enum [outdoor|room|reduce] | True | select.thermostat_hc1_reduce_mode | select.thermostat_hc1_reducemode | |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | noreducetemp | no reduce below temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_no_reduce_below_temperature | number.thermostat_hc1_noreducetemp |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | reducetemp | off/reduce switch temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_off/reduce_switch_temperature | number.thermostat_hc1_reducetemp |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | dhwprio | dhw priority | boolean | True | switch.thermostat_hc1_dhw_priority | switch.thermostat_hc1_dhwprio | |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | cooling | cooling | boolean | True | switch.thermostat_hc1_cooling | switch.thermostat_hc1_cooling | |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | coolingon | cooling | boolean | False | binary_sensor.thermostat_hc1_cooling | binary_sensor.thermostat_hc1_coolingon | |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | hpmode | HP Mode | enum [heating|cooling|heating&cooling] | True | select.thermostat_hc1_HP_Mode | select.thermostat_hc1_hpmode | |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | dewoffset | dew point offset | uint8 (>=2<=10) | K | True | number.thermostat_hc1_dew_point_offset | number.thermostat_hc1_dewoffset |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | roomtempdiff | room temp difference | uint8 (>=0<=254) | K | True | number.thermostat_hc1_room_temp_difference | number.thermostat_hc1_roomtempdiff |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | hpminflowtemp | HP min. flow temp. | uint8 (>=0<=254) | C | True | number.thermostat_hc1_HP_min._flow_temp. | number.thermostat_hc1_hpminflowtemp |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | control | control device | enum [RC310|RC200|RC100|RC100H|TC100] | True | select.thermostat_hc1_control_device | select.thermostat_hc1_control | |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | remotetemp | room temperature from remote | int16 (>=-1<=101) | C | True | number.thermostat_hc1_room_temperature_from_remote | number.thermostat_hc1_remotetemp |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | remotehum | room humidity from remote | uint8 (>=-1<=101) | % | True | number.thermostat_hc1_room_humidity_from_remote | number.thermostat_hc1_remotehum |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | heatondelay | heat-on delay | uint8 (>=1<=48) | hours | True | number.thermostat_hc1_heat-on_delay | number.thermostat_hc1_heatondelay |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | heatoffdelay | heat-off delay | uint8 (>=1<=48) | hours | True | number.thermostat_hc1_heat-off_delay | number.thermostat_hc1_heatoffdelay |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | instantstart | instant start | uint8 (>=1<=10) | K | True | number.thermostat_hc1_instant_start | number.thermostat_hc1_instantstart |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | boost | boost mode | boolean | True | switch.thermostat_hc1_boost_mode | switch.thermostat_hc1_boost | |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | boosttime | boost time | uint8 (>=0<=254) | hours | True | number.thermostat_hc1_boost_time | number.thermostat_hc1_boosttime |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | mode | mode | enum [off|normal|comfort|auto|own prog] | True | select.thermostat_dhw_mode | select.thermostat_dhw_mode | |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | settemp | set temperature | uint8 (>=0<=254) | C | True | number.thermostat_dhw_set_temperature | number.thermostat_dhw_settemp |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | settemplow | set low temperature | uint8 (>=0<=254) | C | True | number.thermostat_dhw_set_low_temperature | number.thermostat_dhw_settemplow |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | circmode | circulation pump mode | enum [off|on|auto|own prog] | True | select.thermostat_dhw_circulation_pump_mode | select.thermostat_dhw_circmode | |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | chargeduration | charge duration | uint8 (>=0<=3810) | minutes | True | number.thermostat_dhw_charge_duration | number.thermostat_dhw_chargeduration |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | charge | charge | boolean | True | switch.thermostat_dhw_charge | switch.thermostat_dhw_charge | |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | extra | extra | uint8 (>=0<=254) | C | False | sensor.thermostat_dhw_extra | sensor.thermostat_dhw_extra |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | disinfecting | disinfecting | boolean | True | switch.thermostat_dhw_disinfecting | switch.thermostat_dhw_disinfecting | |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | disinfectday | disinfection day | enum [mo|tu|we|th|fr|sa|su|all] | True | select.thermostat_dhw_disinfection_day | select.thermostat_dhw_disinfectday | |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | disinfecttime | disinfection time | uint8 (>=0<=1431) | minutes | True | number.thermostat_dhw_disinfection_time | number.thermostat_dhw_disinfecttime |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | dailyheating | daily heating | boolean | True | switch.thermostat_dhw_daily_heating | switch.thermostat_dhw_dailyheating | |
RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 | thermostat | 158 | dailyheattime | daily heating time | uint8 (>=0<=1431) | minutes | True | number.thermostat_dhw_daily_heating_time | number.thermostat_dhw_dailyheattime |
RC100/Moduline 1000/1010 | thermostat | 165 | errorcode | error code | string | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | |
RC100/Moduline 1000/1010 | thermostat | 165 | lastcode | last error code | string | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | |
RC100/Moduline 1000/1010 | thermostat | 165 | datetime | date/time | string | True | sensor.thermostat_date/time | sensor.thermostat_datetime | |
RC100/Moduline 1000/1010 | thermostat | 165 | intoffset | internal temperature offset | int8 (>=-12<=12) | C | True | number.thermostat_internal_temperature_offset | number.thermostat_intoffset |
RC100/Moduline 1000/1010 | thermostat | 165 | floordry | floor drying | enum [off|start|heat|hold|cool|end] | False | sensor.thermostat_floor_drying | sensor.thermostat_floordry | |
RC100/Moduline 1000/1010 | thermostat | 165 | dampedoutdoortemp | damped outdoor temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_damped_outdoor_temperature | sensor.thermostat_dampedoutdoortemp |
RC100/Moduline 1000/1010 | thermostat | 165 | floordrytemp | floor drying temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_floor_drying_temperature | sensor.thermostat_floordrytemp |
RC100/Moduline 1000/1010 | thermostat | 165 | building | building type | enum [light|medium|heavy] | True | select.thermostat_building_type | select.thermostat_building | |
RC100/Moduline 1000/1010 | thermostat | 165 | minexttemp | minimal external temperature | int8 (>=-126<=126) | C | True | number.thermostat_minimal_external_temperature | number.thermostat_minexttemp |
RC100/Moduline 1000/1010 | thermostat | 165 | damping | damping outdoor temperature | boolean | True | switch.thermostat_damping_outdoor_temperature | switch.thermostat_damping | |
RC100/Moduline 1000/1010 | thermostat | 165 | hybridstrategy | hybrid control strategy | enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] | True | select.thermostat_hybrid_control_strategy | select.thermostat_hybridstrategy | |
RC100/Moduline 1000/1010 | thermostat | 165 | switchovertemp | outside switchover temperature | int8 (>=-20<=20) | C | True | number.thermostat_outside_switchover_temperature | number.thermostat_switchovertemp |
RC100/Moduline 1000/1010 | thermostat | 165 | energycostratio | energy cost ratio | uint8 (>=0<=20) | True | number.thermostat_energy_cost_ratio | number.thermostat_energycostratio | |
RC100/Moduline 1000/1010 | thermostat | 165 | fossilefactor | fossile energy factor | uint8 (>=0<=5) | True | number.thermostat_fossile_energy_factor | number.thermostat_fossilefactor | |
RC100/Moduline 1000/1010 | thermostat | 165 | electricfactor | electric energy factor | uint8 (>=0<=5) | True | number.thermostat_electric_energy_factor | number.thermostat_electricfactor | |
RC100/Moduline 1000/1010 | thermostat | 165 | delayboiler | delay boiler support | uint8 (>=5<=120) | minutes | True | number.thermostat_delay_boiler_support | number.thermostat_delayboiler |
RC100/Moduline 1000/1010 | thermostat | 165 | tempdiffboiler | temp diff boiler support | uint8 (>=1<=99) | C | True | number.thermostat_temp_diff_boiler_support | number.thermostat_tempdiffboiler |
RC100/Moduline 1000/1010 | thermostat | 165 | pvenabledhw | enable raise dhw | boolean | True | switch.thermostat_enable_raise_dhw | switch.thermostat_pvenabledhw | |
RC100/Moduline 1000/1010 | thermostat | 165 | pvraiseheat | raise heating with PV | int8 (>=0<=5) | K | True | number.thermostat_raise_heating_with_PV | number.thermostat_pvraiseheat |
RC100/Moduline 1000/1010 | thermostat | 165 | pvlowercool | lower cooling with PV | int8 (>=-5<=0) | K | True | number.thermostat_lower_cooling_with_PV | number.thermostat_pvlowercool |
RC100/Moduline 1000/1010 | thermostat | 165 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp |
RC100/Moduline 1000/1010 | thermostat | 165 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp |
RC100/Moduline 1000/1010 | thermostat | 165 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | |
RC100/Moduline 1000/1010 | thermostat | 165 | mode | mode | enum [manual|auto] | True | select.thermostat_hc1_mode | select.thermostat_hc1_mode | |
RC100/Moduline 1000/1010 | thermostat | 165 | modetype | mode type | enum [eco|comfort] | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | |
RC100/Moduline 1000/1010 | thermostat | 165 | ecotemp | eco temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_eco_temperature | number.thermostat_hc1_ecotemp |
RC100/Moduline 1000/1010 | thermostat | 165 | manualtemp | manual temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_manual_temperature | number.thermostat_hc1_manualtemp |
RC100/Moduline 1000/1010 | thermostat | 165 | comforttemp | comfort temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_comfort_temperature | number.thermostat_hc1_comforttemp |
RC100/Moduline 1000/1010 | thermostat | 165 | summertemp | summer temperature | uint8 (>=10<=30) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp |
RC100/Moduline 1000/1010 | thermostat | 165 | designtemp | design temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_design_temperature | number.thermostat_hc1_designtemp |
RC100/Moduline 1000/1010 | thermostat | 165 | offsettemp | offset temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_offset_temperature | number.thermostat_hc1_offsettemp |
RC100/Moduline 1000/1010 | thermostat | 165 | minflowtemp | min flow temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp |
RC100/Moduline 1000/1010 | thermostat | 165 | maxflowtemp | max flow temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp |
RC100/Moduline 1000/1010 | thermostat | 165 | roominfluence | room influence | uint8 (>=0<=254) | C | True | number.thermostat_hc1_room_influence | number.thermostat_hc1_roominfluence |
RC100/Moduline 1000/1010 | thermostat | 165 | roominflfactor | room influence factor | uint8 (>=0<=25) | True | number.thermostat_hc1_room_influence_factor | number.thermostat_hc1_roominflfactor | |
RC100/Moduline 1000/1010 | thermostat | 165 | curroominfl | current room influence | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_influence | sensor.thermostat_hc1_curroominfl |
RC100/Moduline 1000/1010 | thermostat | 165 | nofrostmode | nofrost mode | enum [room|outdoor|room outdoor] | True | select.thermostat_hc1_nofrost_mode | select.thermostat_hc1_nofrostmode | |
RC100/Moduline 1000/1010 | thermostat | 165 | nofrosttemp | nofrost temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_nofrost_temperature | number.thermostat_hc1_nofrosttemp |
RC100/Moduline 1000/1010 | thermostat | 165 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp |
RC100/Moduline 1000/1010 | thermostat | 165 | heatingtype | heating type | enum [off|radiator|convector|floor] | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | |
RC100/Moduline 1000/1010 | thermostat | 165 | summersetmode | set summer mode | enum [summer|auto|winter] | True | select.thermostat_hc1_set_summer_mode | select.thermostat_hc1_summersetmode | |
RC100/Moduline 1000/1010 | thermostat | 165 | hpoperatingmode | heatpump operating mode | enum [off|auto|heating|cooling] | True | select.thermostat_hc1_heatpump_operating_mode | select.thermostat_hc1_hpoperatingmode | |
RC100/Moduline 1000/1010 | thermostat | 165 | summermode | summer mode | enum [winter|summer] | False | sensor.thermostat_hc1_summer_mode | sensor.thermostat_hc1_summermode | |
RC100/Moduline 1000/1010 | thermostat | 165 | hpoperatingstate | heatpump operating state | enum [heating|off|cooling] | False | sensor.thermostat_hc1_heatpump_operating_state | sensor.thermostat_hc1_hpoperatingstate | |
RC100/Moduline 1000/1010 | thermostat | 165 | controlmode | control mode | enum [optimized|simple|n/a|room|power] | True | select.thermostat_hc1_control_mode | select.thermostat_hc1_controlmode | |
RC100/Moduline 1000/1010 | thermostat | 165 | program | program | enum [prog 1|prog 2] | True | select.thermostat_hc1_program | select.thermostat_hc1_program | |
RC100/Moduline 1000/1010 | thermostat | 165 | tempautotemp | temporary set temperature automode | int8 (>=-1<=30) | C | True | number.thermostat_hc1_temporary_set_temperature_automode | number.thermostat_hc1_tempautotemp |
RC100/Moduline 1000/1010 | thermostat | 165 | remoteseltemp | temporary set temperature from remote | int8 (>=-63<=63) | C | False | sensor.thermostat_hc1_temporary_set_temperature_from_remote | sensor.thermostat_hc1_remoteseltemp |
RC100/Moduline 1000/1010 | thermostat | 165 | fastheatup | fast heatup | uint8 (>=0<=100) | % | True | number.thermostat_hc1_fast_heatup | number.thermostat_hc1_fastheatup |
RC100/Moduline 1000/1010 | thermostat | 165 | switchonoptimization | switch-on optimization | boolean | True | switch.thermostat_hc1_switch-on_optimization | switch.thermostat_hc1_switchonoptimization | |
RC100/Moduline 1000/1010 | thermostat | 165 | reducemode | reduce mode | enum [outdoor|room|reduce] | True | select.thermostat_hc1_reduce_mode | select.thermostat_hc1_reducemode | |
RC100/Moduline 1000/1010 | thermostat | 165 | noreducetemp | no reduce below temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_no_reduce_below_temperature | number.thermostat_hc1_noreducetemp |
RC100/Moduline 1000/1010 | thermostat | 165 | reducetemp | off/reduce switch temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_off/reduce_switch_temperature | number.thermostat_hc1_reducetemp |
RC100/Moduline 1000/1010 | thermostat | 165 | dhwprio | dhw priority | boolean | True | switch.thermostat_hc1_dhw_priority | switch.thermostat_hc1_dhwprio | |
RC100/Moduline 1000/1010 | thermostat | 165 | cooling | cooling | boolean | True | switch.thermostat_hc1_cooling | switch.thermostat_hc1_cooling | |
RC100/Moduline 1000/1010 | thermostat | 165 | coolingon | cooling | boolean | False | binary_sensor.thermostat_hc1_cooling | binary_sensor.thermostat_hc1_coolingon | |
RC100/Moduline 1000/1010 | thermostat | 165 | hpmode | HP Mode | enum [heating|cooling|heating&cooling] | True | select.thermostat_hc1_HP_Mode | select.thermostat_hc1_hpmode | |
RC100/Moduline 1000/1010 | thermostat | 165 | dewoffset | dew point offset | uint8 (>=2<=10) | K | True | number.thermostat_hc1_dew_point_offset | number.thermostat_hc1_dewoffset |
RC100/Moduline 1000/1010 | thermostat | 165 | roomtempdiff | room temp difference | uint8 (>=0<=254) | K | True | number.thermostat_hc1_room_temp_difference | number.thermostat_hc1_roomtempdiff |
RC100/Moduline 1000/1010 | thermostat | 165 | hpminflowtemp | HP min. flow temp. | uint8 (>=0<=254) | C | True | number.thermostat_hc1_HP_min._flow_temp. | number.thermostat_hc1_hpminflowtemp |
RC100/Moduline 1000/1010 | thermostat | 165 | control | control device | enum [RC310|RC200|RC100|RC100H|TC100] | True | select.thermostat_hc1_control_device | select.thermostat_hc1_control | |
RC100/Moduline 1000/1010 | thermostat | 165 | remotetemp | room temperature from remote | int16 (>=-1<=101) | C | True | number.thermostat_hc1_room_temperature_from_remote | number.thermostat_hc1_remotetemp |
RC100/Moduline 1000/1010 | thermostat | 165 | remotehum | room humidity from remote | uint8 (>=-1<=101) | % | True | number.thermostat_hc1_room_humidity_from_remote | number.thermostat_hc1_remotehum |
RC100/Moduline 1000/1010 | thermostat | 165 | heatondelay | heat-on delay | uint8 (>=1<=48) | hours | True | number.thermostat_hc1_heat-on_delay | number.thermostat_hc1_heatondelay |
RC100/Moduline 1000/1010 | thermostat | 165 | heatoffdelay | heat-off delay | uint8 (>=1<=48) | hours | True | number.thermostat_hc1_heat-off_delay | number.thermostat_hc1_heatoffdelay |
RC100/Moduline 1000/1010 | thermostat | 165 | instantstart | instant start | uint8 (>=1<=10) | K | True | number.thermostat_hc1_instant_start | number.thermostat_hc1_instantstart |
RC100/Moduline 1000/1010 | thermostat | 165 | boost | boost mode | boolean | True | switch.thermostat_hc1_boost_mode | switch.thermostat_hc1_boost | |
RC100/Moduline 1000/1010 | thermostat | 165 | boosttime | boost time | uint8 (>=0<=254) | hours | True | number.thermostat_hc1_boost_time | number.thermostat_hc1_boosttime |
RC100/Moduline 1000/1010 | thermostat | 165 | mode | mode | enum [off|normal|comfort|auto|own prog] | True | select.thermostat_dhw_mode | select.thermostat_dhw_mode | |
RC100/Moduline 1000/1010 | thermostat | 165 | settemp | set temperature | uint8 (>=0<=254) | C | True | number.thermostat_dhw_set_temperature | number.thermostat_dhw_settemp |
RC100/Moduline 1000/1010 | thermostat | 165 | settemplow | set low temperature | uint8 (>=0<=254) | C | True | number.thermostat_dhw_set_low_temperature | number.thermostat_dhw_settemplow |
RC100/Moduline 1000/1010 | thermostat | 165 | circmode | circulation pump mode | enum [off|on|auto|own prog] | True | select.thermostat_dhw_circulation_pump_mode | select.thermostat_dhw_circmode | |
RC100/Moduline 1000/1010 | thermostat | 165 | chargeduration | charge duration | uint8 (>=0<=3810) | minutes | True | number.thermostat_dhw_charge_duration | number.thermostat_dhw_chargeduration |
RC100/Moduline 1000/1010 | thermostat | 165 | charge | charge | boolean | True | switch.thermostat_dhw_charge | switch.thermostat_dhw_charge | |
RC100/Moduline 1000/1010 | thermostat | 165 | extra | extra | uint8 (>=0<=254) | C | False | sensor.thermostat_dhw_extra | sensor.thermostat_dhw_extra |
RC100/Moduline 1000/1010 | thermostat | 165 | disinfecting | disinfecting | boolean | True | switch.thermostat_dhw_disinfecting | switch.thermostat_dhw_disinfecting | |
RC100/Moduline 1000/1010 | thermostat | 165 | disinfectday | disinfection day | enum [mo|tu|we|th|fr|sa|su|all] | True | select.thermostat_dhw_disinfection_day | select.thermostat_dhw_disinfectday | |
RC100/Moduline 1000/1010 | thermostat | 165 | disinfecttime | disinfection time | uint8 (>=0<=1431) | minutes | True | number.thermostat_dhw_disinfection_time | number.thermostat_dhw_disinfecttime |
RC100/Moduline 1000/1010 | thermostat | 165 | dailyheating | daily heating | boolean | True | switch.thermostat_dhw_daily_heating | switch.thermostat_dhw_dailyheating | |
RC100/Moduline 1000/1010 | thermostat | 165 | dailyheattime | daily heating time | uint8 (>=0<=1431) | minutes | True | number.thermostat_dhw_daily_heating_time | number.thermostat_dhw_dailyheattime |
Rego 2000/3000 | thermostat | 172 | errorcode | error code | string | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | |
Rego 2000/3000 | thermostat | 172 | lastcode | last error code | string | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | |
Rego 2000/3000 | thermostat | 172 | datetime | date/time | string | True | sensor.thermostat_date/time | sensor.thermostat_datetime | |
Rego 2000/3000 | thermostat | 172 | intoffset | internal temperature offset | int8 (>=-12<=12) | C | True | number.thermostat_internal_temperature_offset | number.thermostat_intoffset |
Rego 2000/3000 | thermostat | 172 | floordry | floor drying | enum [off|start|heat|hold|cool|end] | False | sensor.thermostat_floor_drying | sensor.thermostat_floordry | |
Rego 2000/3000 | thermostat | 172 | dampedoutdoortemp | damped outdoor temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_damped_outdoor_temperature | sensor.thermostat_dampedoutdoortemp |
Rego 2000/3000 | thermostat | 172 | floordrytemp | floor drying temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_floor_drying_temperature | sensor.thermostat_floordrytemp |
Rego 2000/3000 | thermostat | 172 | building | building type | enum [light|medium|heavy] | True | select.thermostat_building_type | select.thermostat_building | |
Rego 2000/3000 | thermostat | 172 | minexttemp | minimal external temperature | int8 (>=-126<=126) | C | True | number.thermostat_minimal_external_temperature | number.thermostat_minexttemp |
Rego 2000/3000 | thermostat | 172 | damping | damping outdoor temperature | boolean | True | switch.thermostat_damping_outdoor_temperature | switch.thermostat_damping | |
Rego 2000/3000 | thermostat | 172 | hybridstrategy | hybrid control strategy | enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] | True | select.thermostat_hybrid_control_strategy | select.thermostat_hybridstrategy | |
Rego 2000/3000 | thermostat | 172 | switchovertemp | outside switchover temperature | int8 (>=-20<=20) | C | True | number.thermostat_outside_switchover_temperature | number.thermostat_switchovertemp |
Rego 2000/3000 | thermostat | 172 | energycostratio | energy cost ratio | uint8 (>=0<=20) | True | number.thermostat_energy_cost_ratio | number.thermostat_energycostratio | |
Rego 2000/3000 | thermostat | 172 | fossilefactor | fossile energy factor | uint8 (>=0<=5) | True | number.thermostat_fossile_energy_factor | number.thermostat_fossilefactor | |
Rego 2000/3000 | thermostat | 172 | electricfactor | electric energy factor | uint8 (>=0<=5) | True | number.thermostat_electric_energy_factor | number.thermostat_electricfactor | |
Rego 2000/3000 | thermostat | 172 | delayboiler | delay boiler support | uint8 (>=5<=120) | minutes | True | number.thermostat_delay_boiler_support | number.thermostat_delayboiler |
Rego 2000/3000 | thermostat | 172 | tempdiffboiler | temp diff boiler support | uint8 (>=1<=99) | C | True | number.thermostat_temp_diff_boiler_support | number.thermostat_tempdiffboiler |
Rego 2000/3000 | thermostat | 172 | pvenabledhw | enable raise dhw | boolean | True | switch.thermostat_enable_raise_dhw | switch.thermostat_pvenabledhw | |
Rego 2000/3000 | thermostat | 172 | pvraiseheat | raise heating with PV | int8 (>=0<=5) | K | True | number.thermostat_raise_heating_with_PV | number.thermostat_pvraiseheat |
Rego 2000/3000 | thermostat | 172 | pvlowercool | lower cooling with PV | int8 (>=-5<=0) | K | True | number.thermostat_lower_cooling_with_PV | number.thermostat_pvlowercool |
Rego 2000/3000 | thermostat | 172 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp |
Rego 2000/3000 | thermostat | 172 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp |
Rego 2000/3000 | thermostat | 172 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | |
Rego 2000/3000 | thermostat | 172 | mode | mode | enum [manual|auto] | True | select.thermostat_hc1_mode | select.thermostat_hc1_mode | |
Rego 2000/3000 | thermostat | 172 | modetype | mode type | enum [eco|comfort] | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | |
Rego 2000/3000 | thermostat | 172 | ecotemp | eco temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_eco_temperature | number.thermostat_hc1_ecotemp |
Rego 2000/3000 | thermostat | 172 | manualtemp | manual temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_manual_temperature | number.thermostat_hc1_manualtemp |
Rego 2000/3000 | thermostat | 172 | comforttemp | comfort temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_comfort_temperature | number.thermostat_hc1_comforttemp |
Rego 2000/3000 | thermostat | 172 | summertemp | summer temperature | uint8 (>=10<=30) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp |
Rego 2000/3000 | thermostat | 172 | designtemp | design temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_design_temperature | number.thermostat_hc1_designtemp |
Rego 2000/3000 | thermostat | 172 | offsettemp | offset temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_offset_temperature | number.thermostat_hc1_offsettemp |
Rego 2000/3000 | thermostat | 172 | minflowtemp | min flow temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp |
Rego 2000/3000 | thermostat | 172 | maxflowtemp | max flow temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp |
Rego 2000/3000 | thermostat | 172 | roominfluence | room influence | uint8 (>=0<=254) | C | True | number.thermostat_hc1_room_influence | number.thermostat_hc1_roominfluence |
Rego 2000/3000 | thermostat | 172 | roominflfactor | room influence factor | uint8 (>=0<=25) | True | number.thermostat_hc1_room_influence_factor | number.thermostat_hc1_roominflfactor | |
Rego 2000/3000 | thermostat | 172 | curroominfl | current room influence | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_influence | sensor.thermostat_hc1_curroominfl |
Rego 2000/3000 | thermostat | 172 | nofrostmode | nofrost mode | enum [room|outdoor|room outdoor] | True | select.thermostat_hc1_nofrost_mode | select.thermostat_hc1_nofrostmode | |
Rego 2000/3000 | thermostat | 172 | nofrosttemp | nofrost temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_nofrost_temperature | number.thermostat_hc1_nofrosttemp |
Rego 2000/3000 | thermostat | 172 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp |
Rego 2000/3000 | thermostat | 172 | heatingtype | heating type | enum [off|radiator|convector|floor] | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | |
Rego 2000/3000 | thermostat | 172 | summersetmode | set summer mode | enum [summer|auto|winter] | True | select.thermostat_hc1_set_summer_mode | select.thermostat_hc1_summersetmode | |
Rego 2000/3000 | thermostat | 172 | hpoperatingmode | heatpump operating mode | enum [off|auto|heating|cooling] | True | select.thermostat_hc1_heatpump_operating_mode | select.thermostat_hc1_hpoperatingmode | |
Rego 2000/3000 | thermostat | 172 | summermode | summer mode | enum [winter|summer] | False | sensor.thermostat_hc1_summer_mode | sensor.thermostat_hc1_summermode | |
Rego 2000/3000 | thermostat | 172 | hpoperatingstate | heatpump operating state | enum [heating|off|cooling] | False | sensor.thermostat_hc1_heatpump_operating_state | sensor.thermostat_hc1_hpoperatingstate | |
Rego 2000/3000 | thermostat | 172 | controlmode | control mode | enum [weather compensated|outside basepoint|n/a|room|power|constant] | True | select.thermostat_hc1_control_mode | select.thermostat_hc1_controlmode | |
Rego 2000/3000 | thermostat | 172 | program | program | enum [prog 1|prog 2] | True | select.thermostat_hc1_program | select.thermostat_hc1_program | |
Rego 2000/3000 | thermostat | 172 | tempautotemp | temporary set temperature automode | int8 (>=-1<=30) | C | True | number.thermostat_hc1_temporary_set_temperature_automode | number.thermostat_hc1_tempautotemp |
Rego 2000/3000 | thermostat | 172 | remoteseltemp | temporary set temperature from remote | int8 (>=-63<=63) | C | False | sensor.thermostat_hc1_temporary_set_temperature_from_remote | sensor.thermostat_hc1_remoteseltemp |
Rego 2000/3000 | thermostat | 172 | fastheatup | fast heatup | uint8 (>=0<=100) | % | True | number.thermostat_hc1_fast_heatup | number.thermostat_hc1_fastheatup |
Rego 2000/3000 | thermostat | 172 | switchonoptimization | switch-on optimization | boolean | True | switch.thermostat_hc1_switch-on_optimization | switch.thermostat_hc1_switchonoptimization | |
Rego 2000/3000 | thermostat | 172 | reducemode | reduce mode | enum [outdoor|room|reduce] | True | select.thermostat_hc1_reduce_mode | select.thermostat_hc1_reducemode | |
Rego 2000/3000 | thermostat | 172 | noreducetemp | no reduce below temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_no_reduce_below_temperature | number.thermostat_hc1_noreducetemp |
Rego 2000/3000 | thermostat | 172 | reducetemp | off/reduce switch temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_off/reduce_switch_temperature | number.thermostat_hc1_reducetemp |
Rego 2000/3000 | thermostat | 172 | dhwprio | dhw priority | boolean | True | switch.thermostat_hc1_dhw_priority | switch.thermostat_hc1_dhwprio | |
Rego 2000/3000 | thermostat | 172 | cooling | cooling | boolean | True | switch.thermostat_hc1_cooling | switch.thermostat_hc1_cooling | |
Rego 2000/3000 | thermostat | 172 | coolingon | cooling | boolean | False | binary_sensor.thermostat_hc1_cooling | binary_sensor.thermostat_hc1_coolingon | |
Rego 2000/3000 | thermostat | 172 | hpmode | HP Mode | enum [heating|cooling|heating&cooling] | True | select.thermostat_hc1_HP_Mode | select.thermostat_hc1_hpmode | |
Rego 2000/3000 | thermostat | 172 | dewoffset | dew point offset | uint8 (>=2<=10) | K | True | number.thermostat_hc1_dew_point_offset | number.thermostat_hc1_dewoffset |
Rego 2000/3000 | thermostat | 172 | roomtempdiff | room temp difference | uint8 (>=0<=254) | K | True | number.thermostat_hc1_room_temp_difference | number.thermostat_hc1_roomtempdiff |
Rego 2000/3000 | thermostat | 172 | hpminflowtemp | HP min. flow temp. | uint8 (>=0<=254) | C | True | number.thermostat_hc1_HP_min._flow_temp. | number.thermostat_hc1_hpminflowtemp |
Rego 2000/3000 | thermostat | 172 | control | control device | enum [RC310|RC200|RC100|RC100H|TC100] | True | select.thermostat_hc1_control_device | select.thermostat_hc1_control | |
Rego 2000/3000 | thermostat | 172 | remotetemp | room temperature from remote | int16 (>=-1<=101) | C | True | number.thermostat_hc1_room_temperature_from_remote | number.thermostat_hc1_remotetemp |
Rego 2000/3000 | thermostat | 172 | remotehum | room humidity from remote | uint8 (>=-1<=101) | % | True | number.thermostat_hc1_room_humidity_from_remote | number.thermostat_hc1_remotehum |
Rego 2000/3000 | thermostat | 172 | heatondelay | heat-on delay | uint8 (>=1<=48) | hours | True | number.thermostat_hc1_heat-on_delay | number.thermostat_hc1_heatondelay |
Rego 2000/3000 | thermostat | 172 | heatoffdelay | heat-off delay | uint8 (>=1<=48) | hours | True | number.thermostat_hc1_heat-off_delay | number.thermostat_hc1_heatoffdelay |
Rego 2000/3000 | thermostat | 172 | instantstart | instant start | uint8 (>=1<=10) | K | True | number.thermostat_hc1_instant_start | number.thermostat_hc1_instantstart |
Rego 2000/3000 | thermostat | 172 | boost | boost mode | boolean | True | switch.thermostat_hc1_boost_mode | switch.thermostat_hc1_boost | |
Rego 2000/3000 | thermostat | 172 | boosttime | boost time | uint8 (>=0<=254) | hours | True | number.thermostat_hc1_boost_time | number.thermostat_hc1_boosttime |
Rego 2000/3000 | thermostat | 172 | mode | mode | enum [normal|comfort|eco+] | True | select.thermostat_dhw_mode | select.thermostat_dhw_mode | |
Rego 2000/3000 | thermostat | 172 | settemp | set temperature | uint8 (>=0<=254) | C | True | number.thermostat_dhw_set_temperature | number.thermostat_dhw_settemp |
Rego 2000/3000 | thermostat | 172 | settemplow | set low temperature | uint8 (>=0<=254) | C | True | number.thermostat_dhw_set_low_temperature | number.thermostat_dhw_settemplow |
Rego 2000/3000 | thermostat | 172 | circmode | circulation pump mode | enum [off|on|auto|own prog] | True | select.thermostat_dhw_circulation_pump_mode | select.thermostat_dhw_circmode | |
Rego 2000/3000 | thermostat | 172 | chargeduration | charge duration | uint8 (>=0<=3810) | minutes | True | number.thermostat_dhw_charge_duration | number.thermostat_dhw_chargeduration |
Rego 2000/3000 | thermostat | 172 | charge | charge | boolean | True | switch.thermostat_dhw_charge | switch.thermostat_dhw_charge | |
Rego 2000/3000 | thermostat | 172 | extra | extra | uint8 (>=0<=254) | C | False | sensor.thermostat_dhw_extra | sensor.thermostat_dhw_extra |
Rego 2000/3000 | thermostat | 172 | disinfecting | disinfecting | boolean | True | switch.thermostat_dhw_disinfecting | switch.thermostat_dhw_disinfecting | |
Rego 2000/3000 | thermostat | 172 | disinfectday | disinfection day | enum [mo|tu|we|th|fr|sa|su|all] | True | select.thermostat_dhw_disinfection_day | select.thermostat_dhw_disinfectday | |
Rego 2000/3000 | thermostat | 172 | disinfecttime | disinfection time | uint8 (>=0<=1431) | minutes | True | number.thermostat_dhw_disinfection_time | number.thermostat_dhw_disinfecttime |
Rego 2000/3000 | thermostat | 172 | dailyheating | daily heating | boolean | True | switch.thermostat_dhw_daily_heating | switch.thermostat_dhw_dailyheating | |
Rego 2000/3000 | thermostat | 172 | dailyheattime | daily heating time | uint8 (>=0<=1431) | minutes | True | number.thermostat_dhw_daily_heating_time | number.thermostat_dhw_dailyheattime |
Comfort RF | thermostat | 215 | errorcode | error code | string | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | |
Comfort RF | thermostat | 215 | lastcode | last error code | string | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | |
Comfort RF | thermostat | 215 | datetime | date/time | string | False | sensor.thermostat_date/time | sensor.thermostat_datetime | |
Comfort RF | thermostat | 215 | seltemp | selected room temperature | int16 (>=-15999<=15999) | C | False | sensor.thermostat_hc1_selected_room_temperature | sensor.thermostat_hc1_seltemp |
Comfort RF | thermostat | 215 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp |
Comfort RF | thermostat | 215 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | |
Comfort RF | thermostat | 215 | mode | mode | enum [auto|off] | False | sensor.thermostat_hc1_mode | sensor.thermostat_hc1_mode | |
Comfort RF | thermostat | 215 | modetype | mode type | enum [off|on] | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | |
Comfort RF | thermostat | 215 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp |
CRF200S | thermostat | 216 | errorcode | error code | string | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | |
CRF200S | thermostat | 216 | lastcode | last error code | string | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | |
CRF200S | thermostat | 216 | datetime | date/time | string | False | sensor.thermostat_date/time | sensor.thermostat_datetime | |
CRF200S | thermostat | 216 | seltemp | selected room temperature | int16 (>=-15999<=15999) | C | False | sensor.thermostat_hc1_selected_room_temperature | sensor.thermostat_hc1_seltemp |
CRF200S | thermostat | 216 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp |
CRF200S | thermostat | 216 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | |
CRF200S | thermostat | 216 | mode | mode | enum [auto|off] | False | sensor.thermostat_hc1_mode | sensor.thermostat_hc1_mode | |
CRF200S | thermostat | 216 | modetype | mode type | enum [off|on] | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | |
CRF200S | thermostat | 216 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp |
Comfort+2RF | thermostat | 246 | errorcode | error code | string | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | |
Comfort+2RF | thermostat | 246 | lastcode | last error code | string | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | |
Comfort+2RF | thermostat | 246 | datetime | date/time | string | False | sensor.thermostat_date/time | sensor.thermostat_datetime | |
Comfort+2RF | thermostat | 246 | seltemp | selected room temperature | int16 (>=-15999<=15999) | C | False | sensor.thermostat_hc1_selected_room_temperature | sensor.thermostat_hc1_seltemp |
Comfort+2RF | thermostat | 246 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp |
Comfort+2RF | thermostat | 246 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | |
Comfort+2RF | thermostat | 246 | mode | mode | enum [auto|off] | False | sensor.thermostat_hc1_mode | sensor.thermostat_hc1_mode | |
Comfort+2RF | thermostat | 246 | modetype | mode type | enum [off|on] | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | |
Comfort+2RF | thermostat | 246 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | errorcode | error code | string | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | lastcode | last error code | string | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | datetime | date/time | string | True | sensor.thermostat_date/time | sensor.thermostat_datetime | |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | intoffset | internal temperature offset | int8 (>=-12<=12) | C | True | number.thermostat_internal_temperature_offset | number.thermostat_intoffset |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | floordry | floor drying | enum [off|start|heat|hold|cool|end] | False | sensor.thermostat_floor_drying | sensor.thermostat_floordry | |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | dampedoutdoortemp | damped outdoor temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_damped_outdoor_temperature | sensor.thermostat_dampedoutdoortemp |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | floordrytemp | floor drying temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_floor_drying_temperature | sensor.thermostat_floordrytemp |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | building | building type | enum [light|medium|heavy] | True | select.thermostat_building_type | select.thermostat_building | |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | minexttemp | minimal external temperature | int8 (>=-126<=126) | C | True | number.thermostat_minimal_external_temperature | number.thermostat_minexttemp |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | damping | damping outdoor temperature | boolean | True | switch.thermostat_damping_outdoor_temperature | switch.thermostat_damping | |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | hybridstrategy | hybrid control strategy | enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] | True | select.thermostat_hybrid_control_strategy | select.thermostat_hybridstrategy | |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | switchovertemp | outside switchover temperature | int8 (>=-20<=20) | C | True | number.thermostat_outside_switchover_temperature | number.thermostat_switchovertemp |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | energycostratio | energy cost ratio | uint8 (>=0<=20) | True | number.thermostat_energy_cost_ratio | number.thermostat_energycostratio | |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | fossilefactor | fossile energy factor | uint8 (>=0<=5) | True | number.thermostat_fossile_energy_factor | number.thermostat_fossilefactor | |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | electricfactor | electric energy factor | uint8 (>=0<=5) | True | number.thermostat_electric_energy_factor | number.thermostat_electricfactor | |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | delayboiler | delay boiler support | uint8 (>=5<=120) | minutes | True | number.thermostat_delay_boiler_support | number.thermostat_delayboiler |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | tempdiffboiler | temp diff boiler support | uint8 (>=1<=99) | C | True | number.thermostat_temp_diff_boiler_support | number.thermostat_tempdiffboiler |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | pvenabledhw | enable raise dhw | boolean | True | switch.thermostat_enable_raise_dhw | switch.thermostat_pvenabledhw | |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | pvraiseheat | raise heating with PV | int8 (>=0<=5) | K | True | number.thermostat_raise_heating_with_PV | number.thermostat_pvraiseheat |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | pvlowercool | lower cooling with PV | int8 (>=-5<=0) | K | True | number.thermostat_lower_cooling_with_PV | number.thermostat_pvlowercool |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | mode | mode | enum [off|manual|auto] | True | select.thermostat_hc1_mode | select.thermostat_hc1_mode | |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | modetype | mode type | enum [eco|comfort] | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | ecotemp | eco temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_eco_temperature | number.thermostat_hc1_ecotemp |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | manualtemp | manual temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_manual_temperature | number.thermostat_hc1_manualtemp |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | comforttemp | comfort temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_comfort_temperature | number.thermostat_hc1_comforttemp |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | summertemp | summer temperature | uint8 (>=10<=30) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | designtemp | design temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_design_temperature | number.thermostat_hc1_designtemp |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | offsettemp | offset temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_offset_temperature | number.thermostat_hc1_offsettemp |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | minflowtemp | min flow temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | maxflowtemp | max flow temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | roominfluence | room influence | uint8 (>=0<=254) | C | True | number.thermostat_hc1_room_influence | number.thermostat_hc1_roominfluence |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | roominflfactor | room influence factor | uint8 (>=0<=25) | True | number.thermostat_hc1_room_influence_factor | number.thermostat_hc1_roominflfactor | |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | curroominfl | current room influence | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_influence | sensor.thermostat_hc1_curroominfl |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | nofrostmode | nofrost mode | enum [room|outdoor|room outdoor] | True | select.thermostat_hc1_nofrost_mode | select.thermostat_hc1_nofrostmode | |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | nofrosttemp | nofrost temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_nofrost_temperature | number.thermostat_hc1_nofrosttemp |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | heatingtype | heating type | enum [off|radiator|convector|floor] | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | summersetmode | set summer mode | enum [summer|auto|winter] | True | select.thermostat_hc1_set_summer_mode | select.thermostat_hc1_summersetmode | |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | hpoperatingmode | heatpump operating mode | enum [off|auto|heating|cooling] | True | select.thermostat_hc1_heatpump_operating_mode | select.thermostat_hc1_hpoperatingmode | |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | summermode | summer mode | enum [winter|summer] | False | sensor.thermostat_hc1_summer_mode | sensor.thermostat_hc1_summermode | |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | hpoperatingstate | heatpump operating state | enum [heating|off|cooling] | False | sensor.thermostat_hc1_heatpump_operating_state | sensor.thermostat_hc1_hpoperatingstate | |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | controlmode | control mode | enum [weather compensated|outside basepoint|n/a|room|power|constant] | True | select.thermostat_hc1_control_mode | select.thermostat_hc1_controlmode | |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | program | program | enum [prog 1|prog 2] | True | select.thermostat_hc1_program | select.thermostat_hc1_program | |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | tempautotemp | temporary set temperature automode | int8 (>=-1<=30) | C | True | number.thermostat_hc1_temporary_set_temperature_automode | number.thermostat_hc1_tempautotemp |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | remoteseltemp | temporary set temperature from remote | int8 (>=-63<=63) | C | False | sensor.thermostat_hc1_temporary_set_temperature_from_remote | sensor.thermostat_hc1_remoteseltemp |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | fastheatup | fast heatup | uint8 (>=0<=100) | % | True | number.thermostat_hc1_fast_heatup | number.thermostat_hc1_fastheatup |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | switchonoptimization | switch-on optimization | boolean | True | switch.thermostat_hc1_switch-on_optimization | switch.thermostat_hc1_switchonoptimization | |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | reducemode | reduce mode | enum [outdoor|room|reduce] | True | select.thermostat_hc1_reduce_mode | select.thermostat_hc1_reducemode | |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | noreducetemp | no reduce below temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_no_reduce_below_temperature | number.thermostat_hc1_noreducetemp |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | reducetemp | off/reduce switch temperature | int8 (>=-126<=126) | C | True | number.thermostat_hc1_off/reduce_switch_temperature | number.thermostat_hc1_reducetemp |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | dhwprio | dhw priority | boolean | True | switch.thermostat_hc1_dhw_priority | switch.thermostat_hc1_dhwprio | |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | cooling | cooling | boolean | True | switch.thermostat_hc1_cooling | switch.thermostat_hc1_cooling | |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | coolingon | cooling | boolean | False | binary_sensor.thermostat_hc1_cooling | binary_sensor.thermostat_hc1_coolingon | |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | hpmode | HP Mode | enum [heating|cooling|heating&cooling] | True | select.thermostat_hc1_HP_Mode | select.thermostat_hc1_hpmode | |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | dewoffset | dew point offset | uint8 (>=2<=10) | K | True | number.thermostat_hc1_dew_point_offset | number.thermostat_hc1_dewoffset |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | roomtempdiff | room temp difference | uint8 (>=0<=254) | K | True | number.thermostat_hc1_room_temp_difference | number.thermostat_hc1_roomtempdiff |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | hpminflowtemp | HP min. flow temp. | uint8 (>=0<=254) | C | True | number.thermostat_hc1_HP_min._flow_temp. | number.thermostat_hc1_hpminflowtemp |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | control | control device | enum [RC310|RC200|RC100|RC100H|TC100] | True | select.thermostat_hc1_control_device | select.thermostat_hc1_control | |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | remotetemp | room temperature from remote | int16 (>=-1<=101) | C | True | number.thermostat_hc1_room_temperature_from_remote | number.thermostat_hc1_remotetemp |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | remotehum | room humidity from remote | uint8 (>=-1<=101) | % | True | number.thermostat_hc1_room_humidity_from_remote | number.thermostat_hc1_remotehum |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | heatondelay | heat-on delay | uint8 (>=1<=48) | hours | True | number.thermostat_hc1_heat-on_delay | number.thermostat_hc1_heatondelay |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | heatoffdelay | heat-off delay | uint8 (>=1<=48) | hours | True | number.thermostat_hc1_heat-off_delay | number.thermostat_hc1_heatoffdelay |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | instantstart | instant start | uint8 (>=1<=10) | K | True | number.thermostat_hc1_instant_start | number.thermostat_hc1_instantstart |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | boost | boost mode | boolean | True | switch.thermostat_hc1_boost_mode | switch.thermostat_hc1_boost | |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | boosttime | boost time | uint8 (>=0<=254) | hours | True | number.thermostat_hc1_boost_time | number.thermostat_hc1_boosttime |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | mode | mode | enum [off|eco+|eco|comfort|auto] | True | select.thermostat_dhw_mode | select.thermostat_dhw_mode | |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | settemp | set temperature | uint8 (>=0<=254) | C | True | number.thermostat_dhw_set_temperature | number.thermostat_dhw_settemp |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | settemplow | set low temperature | uint8 (>=0<=254) | C | True | number.thermostat_dhw_set_low_temperature | number.thermostat_dhw_settemplow |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | circmode | circulation pump mode | enum [off|on|auto|own prog] | True | select.thermostat_dhw_circulation_pump_mode | select.thermostat_dhw_circmode | |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | chargeduration | charge duration | uint8 (>=0<=3810) | minutes | True | number.thermostat_dhw_charge_duration | number.thermostat_dhw_chargeduration |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | charge | charge | boolean | True | switch.thermostat_dhw_charge | switch.thermostat_dhw_charge | |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | extra | extra | uint8 (>=0<=254) | C | False | sensor.thermostat_dhw_extra | sensor.thermostat_dhw_extra |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | disinfecting | disinfecting | boolean | True | switch.thermostat_dhw_disinfecting | switch.thermostat_dhw_disinfecting | |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | disinfectday | disinfection day | enum [mo|tu|we|th|fr|sa|su|all] | True | select.thermostat_dhw_disinfection_day | select.thermostat_dhw_disinfectday | |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | disinfecttime | disinfection time | uint8 (>=0<=1431) | minutes | True | number.thermostat_dhw_disinfection_time | number.thermostat_dhw_disinfecttime |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | dailyheating | daily heating | boolean | True | switch.thermostat_dhw_daily_heating | switch.thermostat_dhw_dailyheating | |
Rego 3000/UI800/WSW196i/BC400 | thermostat | 253 | dailyheattime | daily heating time | uint8 (>=0<=1431) | minutes | True | number.thermostat_dhw_daily_heating_time | number.thermostat_dhw_dailyheattime |
ES72/RC20 | thermostat | 66 | errorcode | error code | string | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | |
ES72/RC20 | thermostat | 66 | lastcode | last error code | string | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | |
ES72/RC20 | thermostat | 66 | datetime | date/time | string | False | sensor.thermostat_date/time | sensor.thermostat_datetime | |
ES72/RC20 | thermostat | 66 | minexttemp | minimal external temperature | int8 (>=-126<=126) | C | True | number.thermostat_minimal_external_temperature | number.thermostat_minexttemp |
ES72/RC20 | thermostat | 66 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp |
ES72/RC20 | thermostat | 66 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp |
ES72/RC20 | thermostat | 66 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | |
ES72/RC20 | thermostat | 66 | mode | mode | enum [night|day|auto] | True | select.thermostat_hc1_mode | select.thermostat_hc1_mode | |
ES72/RC20 | thermostat | 66 | modetype | mode type | enum [night|day] | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | |
ES72/RC20 | thermostat | 66 | daytemp | day temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_day_temperature | number.thermostat_hc1_daytemp |
ES72/RC20 | thermostat | 66 | nighttemp | night temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_night_temperature | number.thermostat_hc1_nighttemp |
ES72/RC20 | thermostat | 66 | program | program | enum [family|morning|evening|am|pm|midday|singles|seniors] | True | select.thermostat_hc1_program | select.thermostat_hc1_program | |
ES72/RC20 | thermostat | 66 | minflowtemp | min flow temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp |
ES72/RC20 | thermostat | 66 | maxflowtemp | max flow temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp |
ES72/RC20 | thermostat | 66 | tempautotemp | temporary set temperature automode | uint8 (>=0<=127) | C | True | number.thermostat_hc1_temporary_set_temperature_automode | number.thermostat_hc1_tempautotemp |
ES72/RC20 | thermostat | 66 | heatingtype | heating type | enum [off|radiator|convector|floor] | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | |
ES72/RC20 | thermostat | 66 | summertemp | summer temperature | uint8 (>=10<=30) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp |
ES72/RC20 | thermostat | 66 | summermode | summer mode | enum [winter|summer] | False | sensor.thermostat_hc1_summer_mode | sensor.thermostat_hc1_summermode | |
ES72/RC20 | thermostat | 66 | remotetemp | room temperature from remote | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_room_temperature_from_remote | sensor.thermostat_hc1_remotetemp |
ES73 | thermostat | 76 | errorcode | error code | string | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | |
ES73 | thermostat | 76 | lastcode | last error code | string | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | |
ES73 | thermostat | 76 | datetime | date/time | string | False | sensor.thermostat_date/time | sensor.thermostat_datetime | |
ES73 | thermostat | 76 | display | display | enum [internal temperature|internal setpoint|external temperature|burner temperature|dhw temperature|functioning mode|time|date|smoke temperature] | True | select.thermostat_display | select.thermostat_display | |
ES73 | thermostat | 76 | language | language | enum [german|dutch|french|italian] | False | sensor.thermostat_language | sensor.thermostat_language | |
ES73 | thermostat | 76 | clockoffset | clock offset | int8 (>=-126<=126) | seconds | True | number.thermostat_clock_offset | number.thermostat_clockoffset |
ES73 | thermostat | 76 | intoffset | internal temperature offset | int8 (>=-12<=12) | C | True | number.thermostat_internal_temperature_offset | number.thermostat_intoffset |
ES73 | thermostat | 76 | minexttemp | minimal external temperature | int8 (>=-126<=126) | C | True | number.thermostat_minimal_external_temperature | number.thermostat_minexttemp |
ES73 | thermostat | 76 | inttemp1 | temperature sensor 1 | int16 (>=-3199<=3199) | C | False | sensor.thermostat_temperature_sensor_1 | sensor.thermostat_inttemp1 |
ES73 | thermostat | 76 | inttemp2 | temperature sensor 2 | int16 (>=-3199<=3199) | C | False | sensor.thermostat_temperature_sensor_2 | sensor.thermostat_inttemp2 |
ES73 | thermostat | 76 | damping | damping outdoor temperature | boolean | True | switch.thermostat_damping_outdoor_temperature | switch.thermostat_damping | |
ES73 | thermostat | 76 | dampedoutdoortemp | damped outdoor temperature | int8 (>=-126<=126) | C | False | sensor.thermostat_damped_outdoor_temperature | sensor.thermostat_dampedoutdoortemp |
ES73 | thermostat | 76 | building | building type | enum [light|medium|heavy] | True | select.thermostat_building_type | select.thermostat_building | |
ES73 | thermostat | 76 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp |
ES73 | thermostat | 76 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp |
ES73 | thermostat | 76 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | |
ES73 | thermostat | 76 | mode | mode | enum [night|day|auto] | True | select.thermostat_hc1_mode | select.thermostat_hc1_mode | |
ES73 | thermostat | 76 | modetype | mode type | enum [night|day] | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | |
ES73 | thermostat | 76 | daytemp | day temperature | uint8 (>=10<=30) | C | True | number.thermostat_hc1_day_temperature | number.thermostat_hc1_daytemp |
ES73 | thermostat | 76 | nighttemp | night temperature | uint8 (>=10<=30) | C | True | number.thermostat_hc1_night_temperature | number.thermostat_hc1_nighttemp |
ES73 | thermostat | 76 | designtemp | design temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_design_temperature | number.thermostat_hc1_designtemp |
ES73 | thermostat | 76 | offsettemp | offset temperature | int8 (>=-5<=5) | C | True | number.thermostat_hc1_offset_temperature | number.thermostat_hc1_offsettemp |
ES73 | thermostat | 76 | holidaytemp | holiday temperature | uint8 (>=5<=30) | C | True | number.thermostat_hc1_holiday_temperature | number.thermostat_hc1_holidaytemp |
ES73 | thermostat | 76 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp |
ES73 | thermostat | 76 | summertemp | summer temperature | uint8 (>=9<=25) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp |
ES73 | thermostat | 76 | summermode | summer mode | enum [winter|summer] | False | sensor.thermostat_hc1_summer_mode | sensor.thermostat_hc1_summermode | |
ES73 | thermostat | 76 | holidaymode | holiday mode | boolean | False | binary_sensor.thermostat_hc1_holiday_mode | binary_sensor.thermostat_hc1_holidaymode | |
ES73 | thermostat | 76 | nofrosttemp | nofrost temperature | int8 (>=-20<=10) | C | True | number.thermostat_hc1_nofrost_temperature | number.thermostat_hc1_nofrosttemp |
ES73 | thermostat | 76 | nofrostmode | nofrost mode | enum [off|outdoor|room] | True | select.thermostat_hc1_nofrost_mode | select.thermostat_hc1_nofrostmode | |
ES73 | thermostat | 76 | roominfluence | room influence | uint8 (>=0<=10) | C | True | number.thermostat_hc1_room_influence | number.thermostat_hc1_roominfluence |
ES73 | thermostat | 76 | minflowtemp | min flow temperature | uint8 (>=5<=70) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp |
ES73 | thermostat | 76 | maxflowtemp | max flow temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp |
ES73 | thermostat | 76 | flowtempoffset | flow temperature offset for mixer | uint8 (>=0<=20) | C | True | number.thermostat_hc1_flow_temperature_offset_for_mixer | number.thermostat_hc1_flowtempoffset |
ES73 | thermostat | 76 | heatingtype | heating type | enum [off|radiator|convector|floor] | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | |
ES73 | thermostat | 76 | reducemode | reduce mode | enum [nofrost|reduce|room|outdoor] | True | select.thermostat_hc1_reduce_mode | select.thermostat_hc1_reducemode | |
ES73 | thermostat | 76 | controlmode | control mode | enum [outdoor|room] | True | select.thermostat_hc1_control_mode | select.thermostat_hc1_controlmode | |
ES73 | thermostat | 76 | control | control device | enum [off|RC20|RC3x] | True | select.thermostat_hc1_control_device | select.thermostat_hc1_control | |
ES73 | thermostat | 76 | holidays | holiday dates | string | True | sensor.thermostat_hc1_holiday_dates | sensor.thermostat_hc1_holidays | |
ES73 | thermostat | 76 | vacations | vacation dates | string | True | sensor.thermostat_hc1_vacation_dates | sensor.thermostat_hc1_vacations | |
ES73 | thermostat | 76 | program | program | enum [own 1|family|morning|evening|am|pm|midday|singles|seniors|new|own 2] | True | select.thermostat_hc1_program | select.thermostat_hc1_program | |
ES73 | thermostat | 76 | pause | pause time | uint8 (>=0<=99) | hours | True | number.thermostat_hc1_pause_time | number.thermostat_hc1_pause |
ES73 | thermostat | 76 | party | party time | uint8 (>=0<=99) | hours | True | number.thermostat_hc1_party_time | number.thermostat_hc1_party |
ES73 | thermostat | 76 | tempautotemp | temporary set temperature automode | uint8 (>=0<=30) | C | True | number.thermostat_hc1_temporary_set_temperature_automode | number.thermostat_hc1_tempautotemp |
ES73 | thermostat | 76 | noreducetemp | no reduce below temperature | int8 (>=-31<=10) | C | True | number.thermostat_hc1_no_reduce_below_temperature | number.thermostat_hc1_noreducetemp |
ES73 | thermostat | 76 | reducetemp | off/reduce switch temperature | int8 (>=-20<=10) | C | True | number.thermostat_hc1_off/reduce_switch_temperature | number.thermostat_hc1_reducetemp |
ES73 | thermostat | 76 | vacreducetemp | vacations off/reduce switch temperature | int8 (>=-20<=10) | C | True | number.thermostat_hc1_vacations_off/reduce_switch_temperature | number.thermostat_hc1_vacreducetemp |
ES73 | thermostat | 76 | vacreducemode | vacations reduce mode | enum [nofrost|reduce|room|outdoor] | True | select.thermostat_hc1_vacations_reduce_mode | select.thermostat_hc1_vacreducemode | |
ES73 | thermostat | 76 | remotetemp | room temperature from remote | int16 (>=-1<=101) | C | True | number.thermostat_hc1_room_temperature_from_remote | number.thermostat_hc1_remotetemp |
ES73 | thermostat | 76 | dhwprio | dhw priority | boolean | True | switch.thermostat_hc1_dhw_priority | switch.thermostat_hc1_dhwprio | |
ES73 | thermostat | 76 | switchonoptimization | switch-on optimization | boolean | True | switch.thermostat_hc1_switch-on_optimization | switch.thermostat_hc1_switchonoptimization | |
ES73 | thermostat | 76 | switchtime1 | own1 program switchtime | string | True | sensor.thermostat_hc1_own1_program_switchtime | sensor.thermostat_hc1_switchtime1 | |
ES73 | thermostat | 76 | switchtime2 | own2 program switchtime | string | True | sensor.thermostat_hc1_own2_program_switchtime | sensor.thermostat_hc1_switchtime2 | |
ES73 | thermostat | 76 | mode | mode | enum [off|on|auto] | True | select.thermostat_dhw_mode | select.thermostat_dhw_mode | |
ES73 | thermostat | 76 | circmode | circulation pump mode | enum [off|on|auto] | True | select.thermostat_dhw_circulation_pump_mode | select.thermostat_dhw_circmode | |
ES73 | thermostat | 76 | progmode | program | enum [std prog|own prog] | True | select.thermostat_dhw_program | select.thermostat_dhw_progmode | |
ES73 | thermostat | 76 | circprog | circulation program | enum [std prog|own prog] | True | select.thermostat_dhw_circulation_program | select.thermostat_dhw_circprog | |
ES73 | thermostat | 76 | disinfecting | disinfecting | boolean | True | switch.thermostat_dhw_disinfecting | switch.thermostat_dhw_disinfecting | |
ES73 | thermostat | 76 | disinfectday | disinfection day | enum [mo|tu|we|th|fr|sa|su|all] | True | select.thermostat_dhw_disinfection_day | select.thermostat_dhw_disinfectday | |
ES73 | thermostat | 76 | disinfecthour | disinfection hour | uint8 (>=0<=23) | True | number.thermostat_dhw_disinfection_hour | number.thermostat_dhw_disinfecthour | |
ES73 | thermostat | 76 | maxtemp | maximum temperature | uint8 (>=0<=254) | C | True | number.thermostat_dhw_maximum_temperature | number.thermostat_dhw_maxtemp |
ES73 | thermostat | 76 | onetimekey | one time key function | boolean | True | switch.thermostat_dhw_one_time_key_function | switch.thermostat_dhw_onetimekey | |
ES73 | thermostat | 76 | switchtime | program switchtime | string | True | sensor.thermostat_dhw_program_switchtime | sensor.thermostat_dhw_switchtime | |
ES73 | thermostat | 76 | circswitchtime | circulation program switchtime | string | True | sensor.thermostat_dhw_circulation_program_switchtime | sensor.thermostat_dhw_circswitchtime | |
ES73 | thermostat | 76 | holidays | holiday dates | string | True | sensor.thermostat_dhw_holiday_dates | sensor.thermostat_dhw_holidays | |
ES73 | thermostat | 76 | vacations | vacation dates | string | True | sensor.thermostat_dhw_vacation_dates | sensor.thermostat_dhw_vacations | |
ES72/RC20 | thermostat | 113 | errorcode | error code | string | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | |
ES72/RC20 | thermostat | 113 | lastcode | last error code | string | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | |
ES72/RC20 | thermostat | 113 | datetime | date/time | string | False | sensor.thermostat_date/time | sensor.thermostat_datetime | |
ES72/RC20 | thermostat | 113 | minexttemp | minimal external temperature | int8 (>=-126<=126) | C | True | number.thermostat_minimal_external_temperature | number.thermostat_minexttemp |
ES72/RC20 | thermostat | 113 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp |
ES72/RC20 | thermostat | 113 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp |
ES72/RC20 | thermostat | 113 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | |
ES72/RC20 | thermostat | 113 | mode | mode | enum [night|day|auto] | True | select.thermostat_hc1_mode | select.thermostat_hc1_mode | |
ES72/RC20 | thermostat | 113 | modetype | mode type | enum [night|day] | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | |
ES72/RC20 | thermostat | 113 | daytemp | day temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_day_temperature | number.thermostat_hc1_daytemp |
ES72/RC20 | thermostat | 113 | nighttemp | night temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_night_temperature | number.thermostat_hc1_nighttemp |
ES72/RC20 | thermostat | 113 | program | program | enum [family|morning|evening|am|pm|midday|singles|seniors] | True | select.thermostat_hc1_program | select.thermostat_hc1_program | |
ES72/RC20 | thermostat | 113 | minflowtemp | min flow temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp |
ES72/RC20 | thermostat | 113 | maxflowtemp | max flow temperature | uint8 (>=0<=254) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp |
ES72/RC20 | thermostat | 113 | tempautotemp | temporary set temperature automode | uint8 (>=0<=127) | C | True | number.thermostat_hc1_temporary_set_temperature_automode | number.thermostat_hc1_tempautotemp |
ES72/RC20 | thermostat | 113 | heatingtype | heating type | enum [off|radiator|convector|floor] | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | |
ES72/RC20 | thermostat | 113 | summertemp | summer temperature | uint8 (>=10<=30) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp |
ES72/RC20 | thermostat | 113 | summermode | summer mode | enum [winter|summer] | False | sensor.thermostat_hc1_summer_mode | sensor.thermostat_hc1_summermode | |
ES72/RC20 | thermostat | 113 | remotetemp | room temperature from remote | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_room_temperature_from_remote | sensor.thermostat_hc1_remotetemp |
ES79 | thermostat | 156 | errorcode | error code | string | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | |
ES79 | thermostat | 156 | lastcode | last error code | string | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | |
ES79 | thermostat | 156 | datetime | date/time | string | True | sensor.thermostat_date/time | sensor.thermostat_datetime | |
ES79 | thermostat | 156 | intoffset | internal temperature offset | int8 (>=-5<=5) | C | True | number.thermostat_internal_temperature_offset | number.thermostat_intoffset |
ES79 | thermostat | 156 | minexttemp | minimal external temperature | int8 (>=-30<=0) | C | True | number.thermostat_minimal_external_temperature | number.thermostat_minexttemp |
ES79 | thermostat | 156 | inttemp1 | temperature sensor 1 | int16 (>=-3199<=3199) | C | False | sensor.thermostat_temperature_sensor_1 | sensor.thermostat_inttemp1 |
ES79 | thermostat | 156 | inttemp2 | temperature sensor 2 | int16 (>=-3199<=3199) | C | False | sensor.thermostat_temperature_sensor_2 | sensor.thermostat_inttemp2 |
ES79 | thermostat | 156 | damping | damping outdoor temperature | boolean | True | switch.thermostat_damping_outdoor_temperature | switch.thermostat_damping | |
ES79 | thermostat | 156 | dampedoutdoortemp | damped outdoor temperature | int8 (>=-126<=126) | C | False | sensor.thermostat_damped_outdoor_temperature | sensor.thermostat_dampedoutdoortemp |
ES79 | thermostat | 156 | building | building type | enum [light|medium|heavy] | True | select.thermostat_building_type | select.thermostat_building | |
ES79 | thermostat | 156 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp |
ES79 | thermostat | 156 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp |
ES79 | thermostat | 156 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | |
ES79 | thermostat | 156 | mode | mode | enum [night|day|auto] | True | select.thermostat_hc1_mode | select.thermostat_hc1_mode | |
ES79 | thermostat | 156 | modetype | mode type | enum [night|day] | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | |
ES79 | thermostat | 156 | daytemp | day temperature | uint8 (>=10<=30) | C | True | number.thermostat_hc1_day_temperature | number.thermostat_hc1_daytemp |
ES79 | thermostat | 156 | nighttemp | night temperature | uint8 (>=10<=30) | C | True | number.thermostat_hc1_night_temperature | number.thermostat_hc1_nighttemp |
ES79 | thermostat | 156 | designtemp | design temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_design_temperature | number.thermostat_hc1_designtemp |
ES79 | thermostat | 156 | offsettemp | offset temperature | int8 (>=-5<=5) | C | True | number.thermostat_hc1_offset_temperature | number.thermostat_hc1_offsettemp |
ES79 | thermostat | 156 | holidaytemp | holiday temperature | uint8 (>=5<=30) | C | True | number.thermostat_hc1_holiday_temperature | number.thermostat_hc1_holidaytemp |
ES79 | thermostat | 156 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp |
ES79 | thermostat | 156 | summertemp | summer temperature | uint8 (>=9<=25) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp |
ES79 | thermostat | 156 | summermode | summer mode | enum [winter|summer] | False | sensor.thermostat_hc1_summer_mode | sensor.thermostat_hc1_summermode | |
ES79 | thermostat | 156 | holidaymode | holiday mode | boolean | False | binary_sensor.thermostat_hc1_holiday_mode | binary_sensor.thermostat_hc1_holidaymode | |
ES79 | thermostat | 156 | nofrosttemp | nofrost temperature | int8 (>=-20<=10) | C | True | number.thermostat_hc1_nofrost_temperature | number.thermostat_hc1_nofrosttemp |
ES79 | thermostat | 156 | nofrostmode | nofrost mode | enum [off|outdoor|room] | True | select.thermostat_hc1_nofrost_mode | select.thermostat_hc1_nofrostmode | |
ES79 | thermostat | 156 | roominfluence | room influence | uint8 (>=0<=10) | C | True | number.thermostat_hc1_room_influence | number.thermostat_hc1_roominfluence |
ES79 | thermostat | 156 | minflowtemp | min flow temperature | uint8 (>=5<=70) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp |
ES79 | thermostat | 156 | maxflowtemp | max flow temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp |
ES79 | thermostat | 156 | flowtempoffset | flow temperature offset for mixer | uint8 (>=0<=20) | C | True | number.thermostat_hc1_flow_temperature_offset_for_mixer | number.thermostat_hc1_flowtempoffset |
ES79 | thermostat | 156 | heatingtype | heating type | enum [off|radiator|convector|floor] | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | |
ES79 | thermostat | 156 | reducemode | reduce mode | enum [nofrost|reduce|room|outdoor] | True | select.thermostat_hc1_reduce_mode | select.thermostat_hc1_reducemode | |
ES79 | thermostat | 156 | controlmode | control mode | enum [outdoor|room] | True | select.thermostat_hc1_control_mode | select.thermostat_hc1_controlmode | |
ES79 | thermostat | 156 | control | control device | enum [off|RC20|RC3x] | True | select.thermostat_hc1_control_device | select.thermostat_hc1_control | |
ES79 | thermostat | 156 | holidays | holiday dates | string | True | sensor.thermostat_hc1_holiday_dates | sensor.thermostat_hc1_holidays | |
ES79 | thermostat | 156 | vacations | vacation dates | string | True | sensor.thermostat_hc1_vacation_dates | sensor.thermostat_hc1_vacations | |
ES79 | thermostat | 156 | program | program | enum [own 1|family|morning|evening|am|pm|midday|singles|seniors|new|own 2] | True | select.thermostat_hc1_program | select.thermostat_hc1_program | |
ES79 | thermostat | 156 | pause | pause time | uint8 (>=0<=99) | hours | True | number.thermostat_hc1_pause_time | number.thermostat_hc1_pause |
ES79 | thermostat | 156 | party | party time | uint8 (>=0<=99) | hours | True | number.thermostat_hc1_party_time | number.thermostat_hc1_party |
ES79 | thermostat | 156 | tempautotemp | temporary set temperature automode | uint8 (>=0<=30) | C | True | number.thermostat_hc1_temporary_set_temperature_automode | number.thermostat_hc1_tempautotemp |
ES79 | thermostat | 156 | noreducetemp | no reduce below temperature | int8 (>=-31<=10) | C | True | number.thermostat_hc1_no_reduce_below_temperature | number.thermostat_hc1_noreducetemp |
ES79 | thermostat | 156 | reducetemp | off/reduce switch temperature | int8 (>=-20<=10) | C | True | number.thermostat_hc1_off/reduce_switch_temperature | number.thermostat_hc1_reducetemp |
ES79 | thermostat | 156 | vacreducetemp | vacations off/reduce switch temperature | int8 (>=-20<=10) | C | True | number.thermostat_hc1_vacations_off/reduce_switch_temperature | number.thermostat_hc1_vacreducetemp |
ES79 | thermostat | 156 | vacreducemode | vacations reduce mode | enum [nofrost|reduce|room|outdoor] | True | select.thermostat_hc1_vacations_reduce_mode | select.thermostat_hc1_vacreducemode | |
ES79 | thermostat | 156 | remotetemp | room temperature from remote | int16 (>=-1<=101) | C | True | number.thermostat_hc1_room_temperature_from_remote | number.thermostat_hc1_remotetemp |
ES79 | thermostat | 156 | dhwprio | dhw priority | boolean | True | switch.thermostat_hc1_dhw_priority | switch.thermostat_hc1_dhwprio | |
ES79 | thermostat | 156 | switchonoptimization | switch-on optimization | boolean | True | switch.thermostat_hc1_switch-on_optimization | switch.thermostat_hc1_switchonoptimization | |
ES79 | thermostat | 156 | switchtime1 | own1 program switchtime | string | True | sensor.thermostat_hc1_own1_program_switchtime | sensor.thermostat_hc1_switchtime1 | |
ES79 | thermostat | 156 | switchtime2 | own2 program switchtime | string | True | sensor.thermostat_hc1_own2_program_switchtime | sensor.thermostat_hc1_switchtime2 | |
ES79 | thermostat | 156 | mode | mode | enum [off|on|auto] | True | select.thermostat_dhw_mode | select.thermostat_dhw_mode | |
ES79 | thermostat | 156 | circmode | circulation pump mode | enum [off|on|auto] | True | select.thermostat_dhw_circulation_pump_mode | select.thermostat_dhw_circmode | |
ES79 | thermostat | 156 | progmode | program | enum [std prog|own prog] | True | select.thermostat_dhw_program | select.thermostat_dhw_progmode | |
ES79 | thermostat | 156 | circprog | circulation program | enum [std prog|own prog] | True | select.thermostat_dhw_circulation_program | select.thermostat_dhw_circprog | |
ES79 | thermostat | 156 | disinfecting | disinfecting | boolean | True | switch.thermostat_dhw_disinfecting | switch.thermostat_dhw_disinfecting | |
ES79 | thermostat | 156 | disinfectday | disinfection day | enum [mo|tu|we|th|fr|sa|su|all] | True | select.thermostat_dhw_disinfection_day | select.thermostat_dhw_disinfectday | |
ES79 | thermostat | 156 | disinfecthour | disinfection hour | uint8 (>=0<=23) | True | number.thermostat_dhw_disinfection_hour | number.thermostat_dhw_disinfecthour | |
ES79 | thermostat | 156 | maxtemp | maximum temperature | uint8 (>=60<=80) | C | True | number.thermostat_dhw_maximum_temperature | number.thermostat_dhw_maxtemp |
ES79 | thermostat | 156 | onetimekey | one time key function | boolean | True | switch.thermostat_dhw_one_time_key_function | switch.thermostat_dhw_onetimekey | |
ES79 | thermostat | 156 | switchtime | program switchtime | string | True | sensor.thermostat_dhw_program_switchtime | sensor.thermostat_dhw_switchtime | |
ES79 | thermostat | 156 | circswitchtime | circulation program switchtime | string | True | sensor.thermostat_dhw_circulation_program_switchtime | sensor.thermostat_dhw_circswitchtime | |
ES79 | thermostat | 156 | holidays | holiday dates | string | True | sensor.thermostat_dhw_holiday_dates | sensor.thermostat_dhw_holidays | |
ES79 | thermostat | 156 | vacations | vacation dates | string | True | sensor.thermostat_dhw_vacation_dates | sensor.thermostat_dhw_vacations | |
FW100 | thermostat | 105 | errorcode | error code | string | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | |
FW100 | thermostat | 105 | lastcode | last error code | string | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | |
FW100 | thermostat | 105 | datetime | date/time | string | True | sensor.thermostat_date/time | sensor.thermostat_datetime | |
FW100 | thermostat | 105 | hybridstrategy | hybrid control strategy | enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] | True | select.thermostat_hybrid_control_strategy | select.thermostat_hybridstrategy | |
FW100 | thermostat | 105 | switchovertemp | outside switchover temperature | int8 (>=-20<=20) | C | True | number.thermostat_outside_switchover_temperature | number.thermostat_switchovertemp |
FW100 | thermostat | 105 | energycostratio | energy cost ratio | uint8 (>=0<=20) | True | number.thermostat_energy_cost_ratio | number.thermostat_energycostratio | |
FW100 | thermostat | 105 | fossilefactor | fossile energy factor | uint8 (>=0<=5) | True | number.thermostat_fossile_energy_factor | number.thermostat_fossilefactor | |
FW100 | thermostat | 105 | electricfactor | electric energy factor | uint8 (>=0<=5) | True | number.thermostat_electric_energy_factor | number.thermostat_electricfactor | |
FW100 | thermostat | 105 | delayboiler | delay boiler support | uint8 (>=5<=120) | minutes | True | number.thermostat_delay_boiler_support | number.thermostat_delayboiler |
FW100 | thermostat | 105 | tempdiffboiler | temp diff boiler support | uint8 (>=1<=99) | C | True | number.thermostat_temp_diff_boiler_support | number.thermostat_tempdiffboiler |
FW100 | thermostat | 105 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp |
FW100 | thermostat | 105 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp |
FW100 | thermostat | 105 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | |
FW100 | thermostat | 105 | mode | mode | enum [nofrost|eco|heat|auto] | True | select.thermostat_hc1_mode | select.thermostat_hc1_mode | |
FW100 | thermostat | 105 | modetype | mode type | enum [nofrost|eco|heat] | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | |
FW100 | thermostat | 105 | heattemp | heat temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_heat_temperature | number.thermostat_hc1_heattemp |
FW100 | thermostat | 105 | ecotemp | eco temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_eco_temperature | number.thermostat_hc1_ecotemp |
FW100 | thermostat | 105 | nofrosttemp | nofrost temperature | int8 (>=-63<=63) | C | True | number.thermostat_hc1_nofrost_temperature | number.thermostat_hc1_nofrosttemp |
FW100 | thermostat | 105 | control | control device | enum [off|FB10|FB100] | True | select.thermostat_hc1_control_device | select.thermostat_hc1_control | |
FW100 | thermostat | 105 | program | program | enum [prog a|prog b|prog c|prog d|prog e|prog f] | True | select.thermostat_hc1_program | select.thermostat_hc1_program | |
FW100 | thermostat | 105 | remotetemp | room temperature from remote | int16 (>=-1<=101) | C | True | number.thermostat_hc1_room_temperature_from_remote | number.thermostat_hc1_remotetemp |
FW100 | thermostat | 105 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp |
FW100 | thermostat | 105 | summertemp | summer temperature | uint8 (>=9<=25) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp |
FW100 | thermostat | 105 | roomsensor | room sensor | enum [extern|intern|auto] | True | select.thermostat_hc1_room_sensor | select.thermostat_hc1_roomsensor | |
FW100 | thermostat | 105 | holidaymode | holiday mode | enum [nofrost|eco|heat|auto] | True | select.thermostat_hc1_holiday_mode | select.thermostat_hc1_holidaymode | |
FW100 | thermostat | 105 | switchonoptimization | switch-on optimization | boolean | True | switch.thermostat_hc1_switch-on_optimization | switch.thermostat_hc1_switchonoptimization | |
FW100 | thermostat | 105 | heatup | heatup | enum [slow|medium|fast] | True | select.thermostat_hc1_heatup | select.thermostat_hc1_heatup | |
FW100 | thermostat | 105 | minflowtemp | min flow temperature | uint8 (>=5<=70) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp |
FW100 | thermostat | 105 | maxflowtemp | max flow temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp |
FW100 | thermostat | 105 | designtemp | design temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_design_temperature | number.thermostat_hc1_designtemp |
FW100 | thermostat | 105 | roominfluence | room influence | enum [off|intern|extern|auto] | True | select.thermostat_hc1_room_influence | select.thermostat_hc1_roominfluence | |
FW100 | thermostat | 105 | roominflfactor | room influence factor | uint8 (>=0<=100) | % | True | number.thermostat_hc1_room_influence_factor | number.thermostat_hc1_roominflfactor |
FW100 | thermostat | 105 | heatingtype | heating type | enum [off|heatingcurve|radiator|convector|floor] | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | |
FW100 | thermostat | 105 | controlmode | control mode | enum [off|unmixed|unmixed IPM|mixed IPM] | True | select.thermostat_hc1_control_mode | select.thermostat_hc1_controlmode | |
FW100 | thermostat | 105 | charge | charge | boolean | True | switch.thermostat_dhw_charge | switch.thermostat_dhw_charge | |
FW200 | thermostat | 106 | errorcode | error code | string | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | |
FW200 | thermostat | 106 | lastcode | last error code | string | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | |
FW200 | thermostat | 106 | datetime | date/time | string | True | sensor.thermostat_date/time | sensor.thermostat_datetime | |
FW200 | thermostat | 106 | hybridstrategy | hybrid control strategy | enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] | True | select.thermostat_hybrid_control_strategy | select.thermostat_hybridstrategy | |
FW200 | thermostat | 106 | switchovertemp | outside switchover temperature | int8 (>=-20<=20) | C | True | number.thermostat_outside_switchover_temperature | number.thermostat_switchovertemp |
FW200 | thermostat | 106 | energycostratio | energy cost ratio | uint8 (>=0<=20) | True | number.thermostat_energy_cost_ratio | number.thermostat_energycostratio | |
FW200 | thermostat | 106 | fossilefactor | fossile energy factor | uint8 (>=0<=5) | True | number.thermostat_fossile_energy_factor | number.thermostat_fossilefactor | |
FW200 | thermostat | 106 | electricfactor | electric energy factor | uint8 (>=0<=5) | True | number.thermostat_electric_energy_factor | number.thermostat_electricfactor | |
FW200 | thermostat | 106 | delayboiler | delay boiler support | uint8 (>=5<=120) | minutes | True | number.thermostat_delay_boiler_support | number.thermostat_delayboiler |
FW200 | thermostat | 106 | tempdiffboiler | temp diff boiler support | uint8 (>=1<=99) | C | True | number.thermostat_temp_diff_boiler_support | number.thermostat_tempdiffboiler |
FW200 | thermostat | 106 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp |
FW200 | thermostat | 106 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp |
FW200 | thermostat | 106 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | |
FW200 | thermostat | 106 | mode | mode | enum [nofrost|eco|heat|auto] | True | select.thermostat_hc1_mode | select.thermostat_hc1_mode | |
FW200 | thermostat | 106 | modetype | mode type | enum [nofrost|eco|heat] | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | |
FW200 | thermostat | 106 | heattemp | heat temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_heat_temperature | number.thermostat_hc1_heattemp |
FW200 | thermostat | 106 | ecotemp | eco temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_eco_temperature | number.thermostat_hc1_ecotemp |
FW200 | thermostat | 106 | nofrosttemp | nofrost temperature | int8 (>=-63<=63) | C | True | number.thermostat_hc1_nofrost_temperature | number.thermostat_hc1_nofrosttemp |
FW200 | thermostat | 106 | control | control device | enum [off|FB10|FB100] | True | select.thermostat_hc1_control_device | select.thermostat_hc1_control | |
FW200 | thermostat | 106 | program | program | enum [prog a|prog b|prog c|prog d|prog e|prog f] | True | select.thermostat_hc1_program | select.thermostat_hc1_program | |
FW200 | thermostat | 106 | remotetemp | room temperature from remote | int16 (>=-1<=101) | C | True | number.thermostat_hc1_room_temperature_from_remote | number.thermostat_hc1_remotetemp |
FW200 | thermostat | 106 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp |
FW200 | thermostat | 106 | summertemp | summer temperature | uint8 (>=9<=25) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp |
FW200 | thermostat | 106 | roomsensor | room sensor | enum [extern|intern|auto] | True | select.thermostat_hc1_room_sensor | select.thermostat_hc1_roomsensor | |
FW200 | thermostat | 106 | holidaymode | holiday mode | enum [nofrost|eco|heat|auto] | True | select.thermostat_hc1_holiday_mode | select.thermostat_hc1_holidaymode | |
FW200 | thermostat | 106 | switchonoptimization | switch-on optimization | boolean | True | switch.thermostat_hc1_switch-on_optimization | switch.thermostat_hc1_switchonoptimization | |
FW200 | thermostat | 106 | heatup | heatup | enum [slow|medium|fast] | True | select.thermostat_hc1_heatup | select.thermostat_hc1_heatup | |
FW200 | thermostat | 106 | minflowtemp | min flow temperature | uint8 (>=5<=70) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp |
FW200 | thermostat | 106 | maxflowtemp | max flow temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp |
FW200 | thermostat | 106 | designtemp | design temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_design_temperature | number.thermostat_hc1_designtemp |
FW200 | thermostat | 106 | roominfluence | room influence | enum [off|intern|extern|auto] | True | select.thermostat_hc1_room_influence | select.thermostat_hc1_roominfluence | |
FW200 | thermostat | 106 | roominflfactor | room influence factor | uint8 (>=0<=100) | % | True | number.thermostat_hc1_room_influence_factor | number.thermostat_hc1_roominflfactor |
FW200 | thermostat | 106 | heatingtype | heating type | enum [off|heatingcurve|radiator|convector|floor] | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | |
FW200 | thermostat | 106 | controlmode | control mode | enum [off|unmixed|unmixed IPM|mixed IPM] | True | select.thermostat_hc1_control_mode | select.thermostat_hc1_controlmode | |
FW200 | thermostat | 106 | charge | charge | boolean | True | switch.thermostat_dhw_charge | switch.thermostat_dhw_charge | |
FR100 | thermostat | 107 | errorcode | error code | string | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | |
FR100 | thermostat | 107 | lastcode | last error code | string | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | |
FR100 | thermostat | 107 | datetime | date/time | string | False | sensor.thermostat_date/time | sensor.thermostat_datetime | |
FR100 | thermostat | 107 | hybridstrategy | hybrid control strategy | enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] | True | select.thermostat_hybrid_control_strategy | select.thermostat_hybridstrategy | |
FR100 | thermostat | 107 | switchovertemp | outside switchover temperature | int8 (>=-20<=20) | C | True | number.thermostat_outside_switchover_temperature | number.thermostat_switchovertemp |
FR100 | thermostat | 107 | energycostratio | energy cost ratio | uint8 (>=0<=20) | True | number.thermostat_energy_cost_ratio | number.thermostat_energycostratio | |
FR100 | thermostat | 107 | fossilefactor | fossile energy factor | uint8 (>=0<=5) | True | number.thermostat_fossile_energy_factor | number.thermostat_fossilefactor | |
FR100 | thermostat | 107 | electricfactor | electric energy factor | uint8 (>=0<=5) | True | number.thermostat_electric_energy_factor | number.thermostat_electricfactor | |
FR100 | thermostat | 107 | delayboiler | delay boiler support | uint8 (>=5<=120) | minutes | True | number.thermostat_delay_boiler_support | number.thermostat_delayboiler |
FR100 | thermostat | 107 | tempdiffboiler | temp diff boiler support | uint8 (>=1<=99) | C | True | number.thermostat_temp_diff_boiler_support | number.thermostat_tempdiffboiler |
FR100 | thermostat | 107 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp |
FR100 | thermostat | 107 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp |
FR100 | thermostat | 107 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | |
FR100 | thermostat | 107 | mode | mode | enum [nofrost|eco|heat|auto] | True | select.thermostat_hc1_mode | select.thermostat_hc1_mode | |
FR100 | thermostat | 107 | modetype | mode type | enum [nofrost|eco|heat] | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | |
FR100 | thermostat | 107 | heattemp | heat temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_heat_temperature | number.thermostat_hc1_heattemp |
FR100 | thermostat | 107 | ecotemp | eco temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_eco_temperature | number.thermostat_hc1_ecotemp |
FR100 | thermostat | 107 | nofrosttemp | nofrost temperature | int8 (>=-63<=63) | C | True | number.thermostat_hc1_nofrost_temperature | number.thermostat_hc1_nofrosttemp |
FR100 | thermostat | 107 | control | control device | enum [off|FB10|FB100] | True | select.thermostat_hc1_control_device | select.thermostat_hc1_control | |
FR100 | thermostat | 107 | program | program | enum [prog a|prog b|prog c|prog d|prog e|prog f] | True | select.thermostat_hc1_program | select.thermostat_hc1_program | |
FR100 | thermostat | 107 | remotetemp | room temperature from remote | int16 (>=-1<=101) | C | True | number.thermostat_hc1_room_temperature_from_remote | number.thermostat_hc1_remotetemp |
FR100 | thermostat | 107 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp |
FR100 | thermostat | 107 | summertemp | summer temperature | uint8 (>=9<=25) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp |
FR100 | thermostat | 107 | roomsensor | room sensor | enum [extern|intern|auto] | True | select.thermostat_hc1_room_sensor | select.thermostat_hc1_roomsensor | |
FR100 | thermostat | 107 | holidaymode | holiday mode | enum [nofrost|eco|heat|auto] | True | select.thermostat_hc1_holiday_mode | select.thermostat_hc1_holidaymode | |
FR100 | thermostat | 107 | switchonoptimization | switch-on optimization | boolean | True | switch.thermostat_hc1_switch-on_optimization | switch.thermostat_hc1_switchonoptimization | |
FR100 | thermostat | 107 | heatup | heatup | enum [slow|medium|fast] | True | select.thermostat_hc1_heatup | select.thermostat_hc1_heatup | |
FR100 | thermostat | 107 | minflowtemp | min flow temperature | uint8 (>=5<=70) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp |
FR100 | thermostat | 107 | maxflowtemp | max flow temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp |
FR100 | thermostat | 107 | designtemp | design temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_design_temperature | number.thermostat_hc1_designtemp |
FR100 | thermostat | 107 | roominfluence | room influence | enum [off|intern|extern|auto] | True | select.thermostat_hc1_room_influence | select.thermostat_hc1_roominfluence | |
FR100 | thermostat | 107 | roominflfactor | room influence factor | uint8 (>=0<=100) | % | True | number.thermostat_hc1_room_influence_factor | number.thermostat_hc1_roominflfactor |
FR100 | thermostat | 107 | heatingtype | heating type | enum [off|heatingcurve|radiator|convector|floor] | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | |
FR100 | thermostat | 107 | controlmode | control mode | enum [off|unmixed|unmixed IPM|mixed IPM] | True | select.thermostat_hc1_control_mode | select.thermostat_hc1_controlmode | |
FR100 | thermostat | 107 | charge | charge | boolean | True | switch.thermostat_dhw_charge | switch.thermostat_dhw_charge | |
FR110 | thermostat | 108 | errorcode | error code | string | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | |
FR110 | thermostat | 108 | lastcode | last error code | string | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | |
FR110 | thermostat | 108 | datetime | date/time | string | False | sensor.thermostat_date/time | sensor.thermostat_datetime | |
FR110 | thermostat | 108 | hybridstrategy | hybrid control strategy | enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] | True | select.thermostat_hybrid_control_strategy | select.thermostat_hybridstrategy | |
FR110 | thermostat | 108 | switchovertemp | outside switchover temperature | int8 (>=-20<=20) | C | True | number.thermostat_outside_switchover_temperature | number.thermostat_switchovertemp |
FR110 | thermostat | 108 | energycostratio | energy cost ratio | uint8 (>=0<=20) | True | number.thermostat_energy_cost_ratio | number.thermostat_energycostratio | |
FR110 | thermostat | 108 | fossilefactor | fossile energy factor | uint8 (>=0<=5) | True | number.thermostat_fossile_energy_factor | number.thermostat_fossilefactor | |
FR110 | thermostat | 108 | electricfactor | electric energy factor | uint8 (>=0<=5) | True | number.thermostat_electric_energy_factor | number.thermostat_electricfactor | |
FR110 | thermostat | 108 | delayboiler | delay boiler support | uint8 (>=5<=120) | minutes | True | number.thermostat_delay_boiler_support | number.thermostat_delayboiler |
FR110 | thermostat | 108 | tempdiffboiler | temp diff boiler support | uint8 (>=1<=99) | C | True | number.thermostat_temp_diff_boiler_support | number.thermostat_tempdiffboiler |
FR110 | thermostat | 108 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp |
FR110 | thermostat | 108 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp |
FR110 | thermostat | 108 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | |
FR110 | thermostat | 108 | mode | mode | enum [nofrost|eco|heat|auto] | True | select.thermostat_hc1_mode | select.thermostat_hc1_mode | |
FR110 | thermostat | 108 | modetype | mode type | enum [nofrost|eco|heat] | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | |
FR110 | thermostat | 108 | heattemp | heat temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_heat_temperature | number.thermostat_hc1_heattemp |
FR110 | thermostat | 108 | ecotemp | eco temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_eco_temperature | number.thermostat_hc1_ecotemp |
FR110 | thermostat | 108 | nofrosttemp | nofrost temperature | int8 (>=-63<=63) | C | True | number.thermostat_hc1_nofrost_temperature | number.thermostat_hc1_nofrosttemp |
FR110 | thermostat | 108 | control | control device | enum [off|FB10|FB100] | True | select.thermostat_hc1_control_device | select.thermostat_hc1_control | |
FR110 | thermostat | 108 | program | program | enum [prog a|prog b|prog c|prog d|prog e|prog f] | True | select.thermostat_hc1_program | select.thermostat_hc1_program | |
FR110 | thermostat | 108 | remotetemp | room temperature from remote | int16 (>=-1<=101) | C | True | number.thermostat_hc1_room_temperature_from_remote | number.thermostat_hc1_remotetemp |
FR110 | thermostat | 108 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp |
FR110 | thermostat | 108 | summertemp | summer temperature | uint8 (>=9<=25) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp |
FR110 | thermostat | 108 | roomsensor | room sensor | enum [extern|intern|auto] | True | select.thermostat_hc1_room_sensor | select.thermostat_hc1_roomsensor | |
FR110 | thermostat | 108 | holidaymode | holiday mode | enum [nofrost|eco|heat|auto] | True | select.thermostat_hc1_holiday_mode | select.thermostat_hc1_holidaymode | |
FR110 | thermostat | 108 | switchonoptimization | switch-on optimization | boolean | True | switch.thermostat_hc1_switch-on_optimization | switch.thermostat_hc1_switchonoptimization | |
FR110 | thermostat | 108 | heatup | heatup | enum [slow|medium|fast] | True | select.thermostat_hc1_heatup | select.thermostat_hc1_heatup | |
FR110 | thermostat | 108 | minflowtemp | min flow temperature | uint8 (>=5<=70) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp |
FR110 | thermostat | 108 | maxflowtemp | max flow temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp |
FR110 | thermostat | 108 | designtemp | design temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_design_temperature | number.thermostat_hc1_designtemp |
FR110 | thermostat | 108 | roominfluence | room influence | enum [off|intern|extern|auto] | True | select.thermostat_hc1_room_influence | select.thermostat_hc1_roominfluence | |
FR110 | thermostat | 108 | roominflfactor | room influence factor | uint8 (>=0<=100) | % | True | number.thermostat_hc1_room_influence_factor | number.thermostat_hc1_roominflfactor |
FR110 | thermostat | 108 | heatingtype | heating type | enum [off|heatingcurve|radiator|convector|floor] | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | |
FR110 | thermostat | 108 | controlmode | control mode | enum [off|unmixed|unmixed IPM|mixed IPM] | True | select.thermostat_hc1_control_mode | select.thermostat_hc1_controlmode | |
FR110 | thermostat | 108 | charge | charge | boolean | True | switch.thermostat_dhw_charge | switch.thermostat_dhw_charge | |
FB10 | thermostat | 109 | errorcode | error code | string | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | |
FB10 | thermostat | 109 | lastcode | last error code | string | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | |
FB10 | thermostat | 109 | datetime | date/time | string | True | sensor.thermostat_date/time | sensor.thermostat_datetime | |
FB10 | thermostat | 109 | hybridstrategy | hybrid control strategy | enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] | True | select.thermostat_hybrid_control_strategy | select.thermostat_hybridstrategy | |
FB10 | thermostat | 109 | switchovertemp | outside switchover temperature | int8 (>=-20<=20) | C | True | number.thermostat_outside_switchover_temperature | number.thermostat_switchovertemp |
FB10 | thermostat | 109 | energycostratio | energy cost ratio | uint8 (>=0<=20) | True | number.thermostat_energy_cost_ratio | number.thermostat_energycostratio | |
FB10 | thermostat | 109 | fossilefactor | fossile energy factor | uint8 (>=0<=5) | True | number.thermostat_fossile_energy_factor | number.thermostat_fossilefactor | |
FB10 | thermostat | 109 | electricfactor | electric energy factor | uint8 (>=0<=5) | True | number.thermostat_electric_energy_factor | number.thermostat_electricfactor | |
FB10 | thermostat | 109 | delayboiler | delay boiler support | uint8 (>=5<=120) | minutes | True | number.thermostat_delay_boiler_support | number.thermostat_delayboiler |
FB10 | thermostat | 109 | tempdiffboiler | temp diff boiler support | uint8 (>=1<=99) | C | True | number.thermostat_temp_diff_boiler_support | number.thermostat_tempdiffboiler |
FB10 | thermostat | 109 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp |
FB10 | thermostat | 109 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp |
FB10 | thermostat | 109 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | |
FB10 | thermostat | 109 | mode | mode | enum [nofrost|eco|heat|auto] | True | select.thermostat_hc1_mode | select.thermostat_hc1_mode | |
FB10 | thermostat | 109 | modetype | mode type | enum [nofrost|eco|heat] | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | |
FB10 | thermostat | 109 | heattemp | heat temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_heat_temperature | number.thermostat_hc1_heattemp |
FB10 | thermostat | 109 | ecotemp | eco temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_eco_temperature | number.thermostat_hc1_ecotemp |
FB10 | thermostat | 109 | nofrosttemp | nofrost temperature | int8 (>=-63<=63) | C | True | number.thermostat_hc1_nofrost_temperature | number.thermostat_hc1_nofrosttemp |
FB10 | thermostat | 109 | control | control device | enum [off|FB10|FB100] | True | select.thermostat_hc1_control_device | select.thermostat_hc1_control | |
FB10 | thermostat | 109 | program | program | enum [prog a|prog b|prog c|prog d|prog e|prog f] | True | select.thermostat_hc1_program | select.thermostat_hc1_program | |
FB10 | thermostat | 109 | remotetemp | room temperature from remote | int16 (>=-1<=101) | C | True | number.thermostat_hc1_room_temperature_from_remote | number.thermostat_hc1_remotetemp |
FB10 | thermostat | 109 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp |
FB10 | thermostat | 109 | summertemp | summer temperature | uint8 (>=9<=25) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp |
FB10 | thermostat | 109 | roomsensor | room sensor | enum [extern|intern|auto] | True | select.thermostat_hc1_room_sensor | select.thermostat_hc1_roomsensor | |
FB10 | thermostat | 109 | holidaymode | holiday mode | enum [nofrost|eco|heat|auto] | True | select.thermostat_hc1_holiday_mode | select.thermostat_hc1_holidaymode | |
FB10 | thermostat | 109 | switchonoptimization | switch-on optimization | boolean | True | switch.thermostat_hc1_switch-on_optimization | switch.thermostat_hc1_switchonoptimization | |
FB10 | thermostat | 109 | heatup | heatup | enum [slow|medium|fast] | True | select.thermostat_hc1_heatup | select.thermostat_hc1_heatup | |
FB10 | thermostat | 109 | minflowtemp | min flow temperature | uint8 (>=5<=70) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp |
FB10 | thermostat | 109 | maxflowtemp | max flow temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp |
FB10 | thermostat | 109 | designtemp | design temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_design_temperature | number.thermostat_hc1_designtemp |
FB10 | thermostat | 109 | roominfluence | room influence | enum [off|intern|extern|auto] | True | select.thermostat_hc1_room_influence | select.thermostat_hc1_roominfluence | |
FB10 | thermostat | 109 | roominflfactor | room influence factor | uint8 (>=0<=100) | % | True | number.thermostat_hc1_room_influence_factor | number.thermostat_hc1_roominflfactor |
FB10 | thermostat | 109 | heatingtype | heating type | enum [off|heatingcurve|radiator|convector|floor] | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | |
FB10 | thermostat | 109 | controlmode | control mode | enum [off|unmixed|unmixed IPM|mixed IPM] | True | select.thermostat_hc1_control_mode | select.thermostat_hc1_controlmode | |
FB10 | thermostat | 109 | charge | charge | boolean | True | switch.thermostat_dhw_charge | switch.thermostat_dhw_charge | |
FB100 | thermostat | 110 | errorcode | error code | string | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | |
FB100 | thermostat | 110 | lastcode | last error code | string | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | |
FB100 | thermostat | 110 | datetime | date/time | string | True | sensor.thermostat_date/time | sensor.thermostat_datetime | |
FB100 | thermostat | 110 | hybridstrategy | hybrid control strategy | enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] | True | select.thermostat_hybrid_control_strategy | select.thermostat_hybridstrategy | |
FB100 | thermostat | 110 | switchovertemp | outside switchover temperature | int8 (>=-20<=20) | C | True | number.thermostat_outside_switchover_temperature | number.thermostat_switchovertemp |
FB100 | thermostat | 110 | energycostratio | energy cost ratio | uint8 (>=0<=20) | True | number.thermostat_energy_cost_ratio | number.thermostat_energycostratio | |
FB100 | thermostat | 110 | fossilefactor | fossile energy factor | uint8 (>=0<=5) | True | number.thermostat_fossile_energy_factor | number.thermostat_fossilefactor | |
FB100 | thermostat | 110 | electricfactor | electric energy factor | uint8 (>=0<=5) | True | number.thermostat_electric_energy_factor | number.thermostat_electricfactor | |
FB100 | thermostat | 110 | delayboiler | delay boiler support | uint8 (>=5<=120) | minutes | True | number.thermostat_delay_boiler_support | number.thermostat_delayboiler |
FB100 | thermostat | 110 | tempdiffboiler | temp diff boiler support | uint8 (>=1<=99) | C | True | number.thermostat_temp_diff_boiler_support | number.thermostat_tempdiffboiler |
FB100 | thermostat | 110 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp |
FB100 | thermostat | 110 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp |
FB100 | thermostat | 110 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | |
FB100 | thermostat | 110 | mode | mode | enum [nofrost|eco|heat|auto] | True | select.thermostat_hc1_mode | select.thermostat_hc1_mode | |
FB100 | thermostat | 110 | modetype | mode type | enum [nofrost|eco|heat] | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | |
FB100 | thermostat | 110 | heattemp | heat temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_heat_temperature | number.thermostat_hc1_heattemp |
FB100 | thermostat | 110 | ecotemp | eco temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_eco_temperature | number.thermostat_hc1_ecotemp |
FB100 | thermostat | 110 | nofrosttemp | nofrost temperature | int8 (>=-63<=63) | C | True | number.thermostat_hc1_nofrost_temperature | number.thermostat_hc1_nofrosttemp |
FB100 | thermostat | 110 | control | control device | enum [off|FB10|FB100] | True | select.thermostat_hc1_control_device | select.thermostat_hc1_control | |
FB100 | thermostat | 110 | program | program | enum [prog a|prog b|prog c|prog d|prog e|prog f] | True | select.thermostat_hc1_program | select.thermostat_hc1_program | |
FB100 | thermostat | 110 | remotetemp | room temperature from remote | int16 (>=-1<=101) | C | True | number.thermostat_hc1_room_temperature_from_remote | number.thermostat_hc1_remotetemp |
FB100 | thermostat | 110 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp |
FB100 | thermostat | 110 | summertemp | summer temperature | uint8 (>=9<=25) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp |
FB100 | thermostat | 110 | roomsensor | room sensor | enum [extern|intern|auto] | True | select.thermostat_hc1_room_sensor | select.thermostat_hc1_roomsensor | |
FB100 | thermostat | 110 | holidaymode | holiday mode | enum [nofrost|eco|heat|auto] | True | select.thermostat_hc1_holiday_mode | select.thermostat_hc1_holidaymode | |
FB100 | thermostat | 110 | switchonoptimization | switch-on optimization | boolean | True | switch.thermostat_hc1_switch-on_optimization | switch.thermostat_hc1_switchonoptimization | |
FB100 | thermostat | 110 | heatup | heatup | enum [slow|medium|fast] | True | select.thermostat_hc1_heatup | select.thermostat_hc1_heatup | |
FB100 | thermostat | 110 | minflowtemp | min flow temperature | uint8 (>=5<=70) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp |
FB100 | thermostat | 110 | maxflowtemp | max flow temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp |
FB100 | thermostat | 110 | designtemp | design temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_design_temperature | number.thermostat_hc1_designtemp |
FB100 | thermostat | 110 | roominfluence | room influence | enum [off|intern|extern|auto] | True | select.thermostat_hc1_room_influence | select.thermostat_hc1_roominfluence | |
FB100 | thermostat | 110 | roominflfactor | room influence factor | uint8 (>=0<=100) | % | True | number.thermostat_hc1_room_influence_factor | number.thermostat_hc1_roominflfactor |
FB100 | thermostat | 110 | heatingtype | heating type | enum [off|heatingcurve|radiator|convector|floor] | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | |
FB100 | thermostat | 110 | controlmode | control mode | enum [off|unmixed|unmixed IPM|mixed IPM] | True | select.thermostat_hc1_control_mode | select.thermostat_hc1_controlmode | |
FB100 | thermostat | 110 | charge | charge | boolean | True | switch.thermostat_dhw_charge | switch.thermostat_dhw_charge | |
FR10 | thermostat | 111 | errorcode | error code | string | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | |
FR10 | thermostat | 111 | lastcode | last error code | string | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | |
FR10 | thermostat | 111 | datetime | date/time | string | False | sensor.thermostat_date/time | sensor.thermostat_datetime | |
FR10 | thermostat | 111 | hybridstrategy | hybrid control strategy | enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] | True | select.thermostat_hybrid_control_strategy | select.thermostat_hybridstrategy | |
FR10 | thermostat | 111 | switchovertemp | outside switchover temperature | int8 (>=-20<=20) | C | True | number.thermostat_outside_switchover_temperature | number.thermostat_switchovertemp |
FR10 | thermostat | 111 | energycostratio | energy cost ratio | uint8 (>=0<=20) | True | number.thermostat_energy_cost_ratio | number.thermostat_energycostratio | |
FR10 | thermostat | 111 | fossilefactor | fossile energy factor | uint8 (>=0<=5) | True | number.thermostat_fossile_energy_factor | number.thermostat_fossilefactor | |
FR10 | thermostat | 111 | electricfactor | electric energy factor | uint8 (>=0<=5) | True | number.thermostat_electric_energy_factor | number.thermostat_electricfactor | |
FR10 | thermostat | 111 | delayboiler | delay boiler support | uint8 (>=5<=120) | minutes | True | number.thermostat_delay_boiler_support | number.thermostat_delayboiler |
FR10 | thermostat | 111 | tempdiffboiler | temp diff boiler support | uint8 (>=1<=99) | C | True | number.thermostat_temp_diff_boiler_support | number.thermostat_tempdiffboiler |
FR10 | thermostat | 111 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp |
FR10 | thermostat | 111 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp |
FR10 | thermostat | 111 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | |
FR10 | thermostat | 111 | mode | mode | enum [nofrost|eco|heat|auto] | True | select.thermostat_hc1_mode | select.thermostat_hc1_mode | |
FR10 | thermostat | 111 | modetype | mode type | enum [nofrost|eco|heat] | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | |
FR10 | thermostat | 111 | heattemp | heat temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_heat_temperature | number.thermostat_hc1_heattemp |
FR10 | thermostat | 111 | ecotemp | eco temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_eco_temperature | number.thermostat_hc1_ecotemp |
FR10 | thermostat | 111 | nofrosttemp | nofrost temperature | int8 (>=-63<=63) | C | True | number.thermostat_hc1_nofrost_temperature | number.thermostat_hc1_nofrosttemp |
FR10 | thermostat | 111 | control | control device | enum [off|FB10|FB100] | True | select.thermostat_hc1_control_device | select.thermostat_hc1_control | |
FR10 | thermostat | 111 | program | program | enum [prog a|prog b|prog c|prog d|prog e|prog f] | True | select.thermostat_hc1_program | select.thermostat_hc1_program | |
FR10 | thermostat | 111 | remotetemp | room temperature from remote | int16 (>=-1<=101) | C | True | number.thermostat_hc1_room_temperature_from_remote | number.thermostat_hc1_remotetemp |
FR10 | thermostat | 111 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp |
FR10 | thermostat | 111 | summertemp | summer temperature | uint8 (>=9<=25) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp |
FR10 | thermostat | 111 | roomsensor | room sensor | enum [extern|intern|auto] | True | select.thermostat_hc1_room_sensor | select.thermostat_hc1_roomsensor | |
FR10 | thermostat | 111 | holidaymode | holiday mode | enum [nofrost|eco|heat|auto] | True | select.thermostat_hc1_holiday_mode | select.thermostat_hc1_holidaymode | |
FR10 | thermostat | 111 | switchonoptimization | switch-on optimization | boolean | True | switch.thermostat_hc1_switch-on_optimization | switch.thermostat_hc1_switchonoptimization | |
FR10 | thermostat | 111 | heatup | heatup | enum [slow|medium|fast] | True | select.thermostat_hc1_heatup | select.thermostat_hc1_heatup | |
FR10 | thermostat | 111 | minflowtemp | min flow temperature | uint8 (>=5<=70) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp |
FR10 | thermostat | 111 | maxflowtemp | max flow temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp |
FR10 | thermostat | 111 | designtemp | design temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_design_temperature | number.thermostat_hc1_designtemp |
FR10 | thermostat | 111 | roominfluence | room influence | enum [off|intern|extern|auto] | True | select.thermostat_hc1_room_influence | select.thermostat_hc1_roominfluence | |
FR10 | thermostat | 111 | roominflfactor | room influence factor | uint8 (>=0<=100) | % | True | number.thermostat_hc1_room_influence_factor | number.thermostat_hc1_roominflfactor |
FR10 | thermostat | 111 | heatingtype | heating type | enum [off|heatingcurve|radiator|convector|floor] | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | |
FR10 | thermostat | 111 | controlmode | control mode | enum [off|unmixed|unmixed IPM|mixed IPM] | True | select.thermostat_hc1_control_mode | select.thermostat_hc1_controlmode | |
FR10 | thermostat | 111 | charge | charge | boolean | True | switch.thermostat_dhw_charge | switch.thermostat_dhw_charge | |
FW500 | thermostat | 116 | errorcode | error code | string | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | |
FW500 | thermostat | 116 | lastcode | last error code | string | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | |
FW500 | thermostat | 116 | datetime | date/time | string | True | sensor.thermostat_date/time | sensor.thermostat_datetime | |
FW500 | thermostat | 116 | hybridstrategy | hybrid control strategy | enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] | True | select.thermostat_hybrid_control_strategy | select.thermostat_hybridstrategy | |
FW500 | thermostat | 116 | switchovertemp | outside switchover temperature | int8 (>=-20<=20) | C | True | number.thermostat_outside_switchover_temperature | number.thermostat_switchovertemp |
FW500 | thermostat | 116 | energycostratio | energy cost ratio | uint8 (>=0<=20) | True | number.thermostat_energy_cost_ratio | number.thermostat_energycostratio | |
FW500 | thermostat | 116 | fossilefactor | fossile energy factor | uint8 (>=0<=5) | True | number.thermostat_fossile_energy_factor | number.thermostat_fossilefactor | |
FW500 | thermostat | 116 | electricfactor | electric energy factor | uint8 (>=0<=5) | True | number.thermostat_electric_energy_factor | number.thermostat_electricfactor | |
FW500 | thermostat | 116 | delayboiler | delay boiler support | uint8 (>=5<=120) | minutes | True | number.thermostat_delay_boiler_support | number.thermostat_delayboiler |
FW500 | thermostat | 116 | tempdiffboiler | temp diff boiler support | uint8 (>=1<=99) | C | True | number.thermostat_temp_diff_boiler_support | number.thermostat_tempdiffboiler |
FW500 | thermostat | 116 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp |
FW500 | thermostat | 116 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp |
FW500 | thermostat | 116 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | |
FW500 | thermostat | 116 | mode | mode | enum [nofrost|eco|heat|auto] | True | select.thermostat_hc1_mode | select.thermostat_hc1_mode | |
FW500 | thermostat | 116 | modetype | mode type | enum [nofrost|eco|heat] | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | |
FW500 | thermostat | 116 | heattemp | heat temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_heat_temperature | number.thermostat_hc1_heattemp |
FW500 | thermostat | 116 | ecotemp | eco temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_eco_temperature | number.thermostat_hc1_ecotemp |
FW500 | thermostat | 116 | nofrosttemp | nofrost temperature | int8 (>=-63<=63) | C | True | number.thermostat_hc1_nofrost_temperature | number.thermostat_hc1_nofrosttemp |
FW500 | thermostat | 116 | control | control device | enum [off|FB10|FB100] | True | select.thermostat_hc1_control_device | select.thermostat_hc1_control | |
FW500 | thermostat | 116 | program | program | enum [prog a|prog b|prog c|prog d|prog e|prog f] | True | select.thermostat_hc1_program | select.thermostat_hc1_program | |
FW500 | thermostat | 116 | remotetemp | room temperature from remote | int16 (>=-1<=101) | C | True | number.thermostat_hc1_room_temperature_from_remote | number.thermostat_hc1_remotetemp |
FW500 | thermostat | 116 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp |
FW500 | thermostat | 116 | summertemp | summer temperature | uint8 (>=9<=25) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp |
FW500 | thermostat | 116 | roomsensor | room sensor | enum [extern|intern|auto] | True | select.thermostat_hc1_room_sensor | select.thermostat_hc1_roomsensor | |
FW500 | thermostat | 116 | holidaymode | holiday mode | enum [nofrost|eco|heat|auto] | True | select.thermostat_hc1_holiday_mode | select.thermostat_hc1_holidaymode | |
FW500 | thermostat | 116 | switchonoptimization | switch-on optimization | boolean | True | switch.thermostat_hc1_switch-on_optimization | switch.thermostat_hc1_switchonoptimization | |
FW500 | thermostat | 116 | heatup | heatup | enum [slow|medium|fast] | True | select.thermostat_hc1_heatup | select.thermostat_hc1_heatup | |
FW500 | thermostat | 116 | minflowtemp | min flow temperature | uint8 (>=5<=70) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp |
FW500 | thermostat | 116 | maxflowtemp | max flow temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp |
FW500 | thermostat | 116 | designtemp | design temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_design_temperature | number.thermostat_hc1_designtemp |
FW500 | thermostat | 116 | roominfluence | room influence | enum [off|intern|extern|auto] | True | select.thermostat_hc1_room_influence | select.thermostat_hc1_roominfluence | |
FW500 | thermostat | 116 | roominflfactor | room influence factor | uint8 (>=0<=100) | % | True | number.thermostat_hc1_room_influence_factor | number.thermostat_hc1_roominflfactor |
FW500 | thermostat | 116 | heatingtype | heating type | enum [off|heatingcurve|radiator|convector|floor] | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | |
FW500 | thermostat | 116 | controlmode | control mode | enum [off|unmixed|unmixed IPM|mixed IPM] | True | select.thermostat_hc1_control_mode | select.thermostat_hc1_controlmode | |
FW500 | thermostat | 116 | charge | charge | boolean | True | switch.thermostat_dhw_charge | switch.thermostat_dhw_charge | |
FR50 | thermostat | 147 | errorcode | error code | string | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | |
FR50 | thermostat | 147 | lastcode | last error code | string | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | |
FR50 | thermostat | 147 | datetime | date/time | string | False | sensor.thermostat_date/time | sensor.thermostat_datetime | |
FR50 | thermostat | 147 | hybridstrategy | hybrid control strategy | enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] | True | select.thermostat_hybrid_control_strategy | select.thermostat_hybridstrategy | |
FR50 | thermostat | 147 | switchovertemp | outside switchover temperature | int8 (>=-20<=20) | C | True | number.thermostat_outside_switchover_temperature | number.thermostat_switchovertemp |
FR50 | thermostat | 147 | energycostratio | energy cost ratio | uint8 (>=0<=20) | True | number.thermostat_energy_cost_ratio | number.thermostat_energycostratio | |
FR50 | thermostat | 147 | fossilefactor | fossile energy factor | uint8 (>=0<=5) | True | number.thermostat_fossile_energy_factor | number.thermostat_fossilefactor | |
FR50 | thermostat | 147 | electricfactor | electric energy factor | uint8 (>=0<=5) | True | number.thermostat_electric_energy_factor | number.thermostat_electricfactor | |
FR50 | thermostat | 147 | delayboiler | delay boiler support | uint8 (>=5<=120) | minutes | True | number.thermostat_delay_boiler_support | number.thermostat_delayboiler |
FR50 | thermostat | 147 | tempdiffboiler | temp diff boiler support | uint8 (>=1<=99) | C | True | number.thermostat_temp_diff_boiler_support | number.thermostat_tempdiffboiler |
FR50 | thermostat | 147 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp |
FR50 | thermostat | 147 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp |
FR50 | thermostat | 147 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | |
FR50 | thermostat | 147 | mode | mode | enum [nofrost|eco|heat|auto] | True | select.thermostat_hc1_mode | select.thermostat_hc1_mode | |
FR50 | thermostat | 147 | modetype | mode type | enum [nofrost|eco|heat] | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | |
FR50 | thermostat | 147 | heattemp | heat temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_heat_temperature | number.thermostat_hc1_heattemp |
FR50 | thermostat | 147 | ecotemp | eco temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_eco_temperature | number.thermostat_hc1_ecotemp |
FR50 | thermostat | 147 | nofrosttemp | nofrost temperature | int8 (>=-63<=63) | C | True | number.thermostat_hc1_nofrost_temperature | number.thermostat_hc1_nofrosttemp |
FR50 | thermostat | 147 | control | control device | enum [off|FB10|FB100] | True | select.thermostat_hc1_control_device | select.thermostat_hc1_control | |
FR50 | thermostat | 147 | program | program | enum [prog a|prog b|prog c|prog d|prog e|prog f] | True | select.thermostat_hc1_program | select.thermostat_hc1_program | |
FR50 | thermostat | 147 | remotetemp | room temperature from remote | int16 (>=-1<=101) | C | True | number.thermostat_hc1_room_temperature_from_remote | number.thermostat_hc1_remotetemp |
FR50 | thermostat | 147 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp |
FR50 | thermostat | 147 | summertemp | summer temperature | uint8 (>=9<=25) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp |
FR50 | thermostat | 147 | roomsensor | room sensor | enum [extern|intern|auto] | True | select.thermostat_hc1_room_sensor | select.thermostat_hc1_roomsensor | |
FR50 | thermostat | 147 | holidaymode | holiday mode | enum [nofrost|eco|heat|auto] | True | select.thermostat_hc1_holiday_mode | select.thermostat_hc1_holidaymode | |
FR50 | thermostat | 147 | switchonoptimization | switch-on optimization | boolean | True | switch.thermostat_hc1_switch-on_optimization | switch.thermostat_hc1_switchonoptimization | |
FR50 | thermostat | 147 | heatup | heatup | enum [slow|medium|fast] | True | select.thermostat_hc1_heatup | select.thermostat_hc1_heatup | |
FR50 | thermostat | 147 | minflowtemp | min flow temperature | uint8 (>=5<=70) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp |
FR50 | thermostat | 147 | maxflowtemp | max flow temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp |
FR50 | thermostat | 147 | designtemp | design temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_design_temperature | number.thermostat_hc1_designtemp |
FR50 | thermostat | 147 | roominfluence | room influence | enum [off|intern|extern|auto] | True | select.thermostat_hc1_room_influence | select.thermostat_hc1_roominfluence | |
FR50 | thermostat | 147 | roominflfactor | room influence factor | uint8 (>=0<=100) | % | True | number.thermostat_hc1_room_influence_factor | number.thermostat_hc1_roominflfactor |
FR50 | thermostat | 147 | heatingtype | heating type | enum [off|heatingcurve|radiator|convector|floor] | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | |
FR50 | thermostat | 147 | controlmode | control mode | enum [off|unmixed|unmixed IPM|mixed IPM] | True | select.thermostat_hc1_control_mode | select.thermostat_hc1_controlmode | |
FR50 | thermostat | 147 | charge | charge | boolean | True | switch.thermostat_dhw_charge | switch.thermostat_dhw_charge | |
FR120 | thermostat | 191 | errorcode | error code | string | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | |
FR120 | thermostat | 191 | lastcode | last error code | string | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | |
FR120 | thermostat | 191 | datetime | date/time | string | False | sensor.thermostat_date/time | sensor.thermostat_datetime | |
FR120 | thermostat | 191 | hybridstrategy | hybrid control strategy | enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] | True | select.thermostat_hybrid_control_strategy | select.thermostat_hybridstrategy | |
FR120 | thermostat | 191 | switchovertemp | outside switchover temperature | int8 (>=-20<=20) | C | True | number.thermostat_outside_switchover_temperature | number.thermostat_switchovertemp |
FR120 | thermostat | 191 | energycostratio | energy cost ratio | uint8 (>=0<=20) | True | number.thermostat_energy_cost_ratio | number.thermostat_energycostratio | |
FR120 | thermostat | 191 | fossilefactor | fossile energy factor | uint8 (>=0<=5) | True | number.thermostat_fossile_energy_factor | number.thermostat_fossilefactor | |
FR120 | thermostat | 191 | electricfactor | electric energy factor | uint8 (>=0<=5) | True | number.thermostat_electric_energy_factor | number.thermostat_electricfactor | |
FR120 | thermostat | 191 | delayboiler | delay boiler support | uint8 (>=5<=120) | minutes | True | number.thermostat_delay_boiler_support | number.thermostat_delayboiler |
FR120 | thermostat | 191 | tempdiffboiler | temp diff boiler support | uint8 (>=1<=99) | C | True | number.thermostat_temp_diff_boiler_support | number.thermostat_tempdiffboiler |
FR120 | thermostat | 191 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp |
FR120 | thermostat | 191 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp |
FR120 | thermostat | 191 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | |
FR120 | thermostat | 191 | mode | mode | enum [nofrost|eco|heat|auto] | True | select.thermostat_hc1_mode | select.thermostat_hc1_mode | |
FR120 | thermostat | 191 | modetype | mode type | enum [nofrost|eco|heat] | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | |
FR120 | thermostat | 191 | heattemp | heat temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_heat_temperature | number.thermostat_hc1_heattemp |
FR120 | thermostat | 191 | ecotemp | eco temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_eco_temperature | number.thermostat_hc1_ecotemp |
FR120 | thermostat | 191 | nofrosttemp | nofrost temperature | int8 (>=-63<=63) | C | True | number.thermostat_hc1_nofrost_temperature | number.thermostat_hc1_nofrosttemp |
FR120 | thermostat | 191 | control | control device | enum [off|FB10|FB100] | True | select.thermostat_hc1_control_device | select.thermostat_hc1_control | |
FR120 | thermostat | 191 | program | program | enum [prog a|prog b|prog c|prog d|prog e|prog f] | True | select.thermostat_hc1_program | select.thermostat_hc1_program | |
FR120 | thermostat | 191 | remotetemp | room temperature from remote | int16 (>=-1<=101) | C | True | number.thermostat_hc1_room_temperature_from_remote | number.thermostat_hc1_remotetemp |
FR120 | thermostat | 191 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp |
FR120 | thermostat | 191 | summertemp | summer temperature | uint8 (>=9<=25) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp |
FR120 | thermostat | 191 | roomsensor | room sensor | enum [extern|intern|auto] | True | select.thermostat_hc1_room_sensor | select.thermostat_hc1_roomsensor | |
FR120 | thermostat | 191 | holidaymode | holiday mode | enum [nofrost|eco|heat|auto] | True | select.thermostat_hc1_holiday_mode | select.thermostat_hc1_holidaymode | |
FR120 | thermostat | 191 | switchonoptimization | switch-on optimization | boolean | True | switch.thermostat_hc1_switch-on_optimization | switch.thermostat_hc1_switchonoptimization | |
FR120 | thermostat | 191 | heatup | heatup | enum [slow|medium|fast] | True | select.thermostat_hc1_heatup | select.thermostat_hc1_heatup | |
FR120 | thermostat | 191 | minflowtemp | min flow temperature | uint8 (>=5<=70) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp |
FR120 | thermostat | 191 | maxflowtemp | max flow temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp |
FR120 | thermostat | 191 | designtemp | design temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_design_temperature | number.thermostat_hc1_designtemp |
FR120 | thermostat | 191 | roominfluence | room influence | enum [off|intern|extern|auto] | True | select.thermostat_hc1_room_influence | select.thermostat_hc1_roominfluence | |
FR120 | thermostat | 191 | roominflfactor | room influence factor | uint8 (>=0<=100) | % | True | number.thermostat_hc1_room_influence_factor | number.thermostat_hc1_roominflfactor |
FR120 | thermostat | 191 | heatingtype | heating type | enum [off|heatingcurve|radiator|convector|floor] | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | |
FR120 | thermostat | 191 | controlmode | control mode | enum [off|unmixed|unmixed IPM|mixed IPM] | True | select.thermostat_hc1_control_mode | select.thermostat_hc1_controlmode | |
FR120 | thermostat | 191 | charge | charge | boolean | True | switch.thermostat_dhw_charge | switch.thermostat_dhw_charge | |
FW120 | thermostat | 192 | errorcode | error code | string | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | |
FW120 | thermostat | 192 | lastcode | last error code | string | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | |
FW120 | thermostat | 192 | datetime | date/time | string | True | sensor.thermostat_date/time | sensor.thermostat_datetime | |
FW120 | thermostat | 192 | hybridstrategy | hybrid control strategy | enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] | True | select.thermostat_hybrid_control_strategy | select.thermostat_hybridstrategy | |
FW120 | thermostat | 192 | switchovertemp | outside switchover temperature | int8 (>=-20<=20) | C | True | number.thermostat_outside_switchover_temperature | number.thermostat_switchovertemp |
FW120 | thermostat | 192 | energycostratio | energy cost ratio | uint8 (>=0<=20) | True | number.thermostat_energy_cost_ratio | number.thermostat_energycostratio | |
FW120 | thermostat | 192 | fossilefactor | fossile energy factor | uint8 (>=0<=5) | True | number.thermostat_fossile_energy_factor | number.thermostat_fossilefactor | |
FW120 | thermostat | 192 | electricfactor | electric energy factor | uint8 (>=0<=5) | True | number.thermostat_electric_energy_factor | number.thermostat_electricfactor | |
FW120 | thermostat | 192 | delayboiler | delay boiler support | uint8 (>=5<=120) | minutes | True | number.thermostat_delay_boiler_support | number.thermostat_delayboiler |
FW120 | thermostat | 192 | tempdiffboiler | temp diff boiler support | uint8 (>=1<=99) | C | True | number.thermostat_temp_diff_boiler_support | number.thermostat_tempdiffboiler |
FW120 | thermostat | 192 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp |
FW120 | thermostat | 192 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp |
FW120 | thermostat | 192 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | |
FW120 | thermostat | 192 | mode | mode | enum [nofrost|eco|heat|auto] | True | select.thermostat_hc1_mode | select.thermostat_hc1_mode | |
FW120 | thermostat | 192 | modetype | mode type | enum [nofrost|eco|heat] | False | sensor.thermostat_hc1_mode_type | sensor.thermostat_hc1_modetype | |
FW120 | thermostat | 192 | heattemp | heat temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_heat_temperature | number.thermostat_hc1_heattemp |
FW120 | thermostat | 192 | ecotemp | eco temperature | uint8 (>=0<=127) | C | True | number.thermostat_hc1_eco_temperature | number.thermostat_hc1_ecotemp |
FW120 | thermostat | 192 | nofrosttemp | nofrost temperature | int8 (>=-63<=63) | C | True | number.thermostat_hc1_nofrost_temperature | number.thermostat_hc1_nofrosttemp |
FW120 | thermostat | 192 | control | control device | enum [off|FB10|FB100] | True | select.thermostat_hc1_control_device | select.thermostat_hc1_control | |
FW120 | thermostat | 192 | program | program | enum [prog a|prog b|prog c|prog d|prog e|prog f] | True | select.thermostat_hc1_program | select.thermostat_hc1_program | |
FW120 | thermostat | 192 | remotetemp | room temperature from remote | int16 (>=-1<=101) | C | True | number.thermostat_hc1_room_temperature_from_remote | number.thermostat_hc1_remotetemp |
FW120 | thermostat | 192 | targetflowtemp | target flow temperature | uint8 (>=0<=254) | C | False | sensor.thermostat_hc1_target_flow_temperature | sensor.thermostat_hc1_targetflowtemp |
FW120 | thermostat | 192 | summertemp | summer temperature | uint8 (>=9<=25) | C | True | number.thermostat_hc1_summer_temperature | number.thermostat_hc1_summertemp |
FW120 | thermostat | 192 | roomsensor | room sensor | enum [extern|intern|auto] | True | select.thermostat_hc1_room_sensor | select.thermostat_hc1_roomsensor | |
FW120 | thermostat | 192 | holidaymode | holiday mode | enum [nofrost|eco|heat|auto] | True | select.thermostat_hc1_holiday_mode | select.thermostat_hc1_holidaymode | |
FW120 | thermostat | 192 | switchonoptimization | switch-on optimization | boolean | True | switch.thermostat_hc1_switch-on_optimization | switch.thermostat_hc1_switchonoptimization | |
FW120 | thermostat | 192 | heatup | heatup | enum [slow|medium|fast] | True | select.thermostat_hc1_heatup | select.thermostat_hc1_heatup | |
FW120 | thermostat | 192 | minflowtemp | min flow temperature | uint8 (>=5<=70) | C | True | number.thermostat_hc1_min_flow_temperature | number.thermostat_hc1_minflowtemp |
FW120 | thermostat | 192 | maxflowtemp | max flow temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_max_flow_temperature | number.thermostat_hc1_maxflowtemp |
FW120 | thermostat | 192 | designtemp | design temperature | uint8 (>=30<=90) | C | True | number.thermostat_hc1_design_temperature | number.thermostat_hc1_designtemp |
FW120 | thermostat | 192 | roominfluence | room influence | enum [off|intern|extern|auto] | True | select.thermostat_hc1_room_influence | select.thermostat_hc1_roominfluence | |
FW120 | thermostat | 192 | roominflfactor | room influence factor | uint8 (>=0<=100) | % | True | number.thermostat_hc1_room_influence_factor | number.thermostat_hc1_roominflfactor |
FW120 | thermostat | 192 | heatingtype | heating type | enum [off|heatingcurve|radiator|convector|floor] | True | select.thermostat_hc1_heating_type | select.thermostat_hc1_heatingtype | |
FW120 | thermostat | 192 | controlmode | control mode | enum [off|unmixed|unmixed IPM|mixed IPM] | True | select.thermostat_hc1_control_mode | select.thermostat_hc1_controlmode | |
FW120 | thermostat | 192 | charge | charge | boolean | True | switch.thermostat_dhw_charge | switch.thermostat_dhw_charge | |
RT800 | thermostat | 3 | errorcode | error code | string | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | |
RT800 | thermostat | 3 | lastcode | last error code | string | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | |
RT800 | thermostat | 3 | datetime | date/time | string | False | sensor.thermostat_date/time | sensor.thermostat_datetime | |
RT800 | thermostat | 3 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp |
RT800 | thermostat | 3 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp |
RT800 | thermostat | 3 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | |
RC100H | thermostat | 200 | errorcode | error code | string | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | |
RC100H | thermostat | 200 | lastcode | last error code | string | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | |
RC100H | thermostat | 200 | datetime | date/time | string | False | sensor.thermostat_date/time | sensor.thermostat_datetime | |
RC100H | thermostat | 200 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp |
RC100H | thermostat | 200 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp |
RC100H | thermostat | 200 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | |
TR120RF/CR20RF | thermostat | 249 | errorcode | error code | string | False | sensor.thermostat_error_code | sensor.thermostat_errorcode | |
TR120RF/CR20RF | thermostat | 249 | lastcode | last error code | string | False | sensor.thermostat_last_error_code | sensor.thermostat_lastcode | |
TR120RF/CR20RF | thermostat | 249 | datetime | date/time | string | False | sensor.thermostat_date/time | sensor.thermostat_datetime | |
TR120RF/CR20RF | thermostat | 249 | seltemp | selected room temperature | int16 (>=0<=30) | C | True | number.thermostat_hc1_selected_room_temperature | number.thermostat_hc1_seltemp |
TR120RF/CR20RF | thermostat | 249 | currtemp | current room temperature | int16 (>=-3199<=3199) | C | False | sensor.thermostat_hc1_current_room_temperature | sensor.thermostat_hc1_currtemp |
TR120RF/CR20RF | thermostat | 249 | haclimate | mqtt discovery current room temperature | enum [selTemp|roomTemp] (>=5<=30) | False | sensor.thermostat_hc1_mqtt_discovery_current_room_temperature | sensor.thermostat_hc1_haclimate | |
MM10 | mixer | 69 | flowtemphc | flow temperature (TC1) | uint16 (>=0<=3199) | C | False | sensor.mixer_hc1_flow_temperature_(TC1) | sensor.mixer_hc1_flowtemphc |
MM10 | mixer | 69 | valvestatus | mixing valve actuator (VC1) | int8 (>=-100<=100) | % | False | sensor.mixer_hc1_mixing_valve_actuator_(VC1) | sensor.mixer_hc1_valvestatus |
MM10 | mixer | 69 | flowsettemp | setpoint flow temperature | uint8 (>=0<=254) | C | True | number.mixer_hc1_setpoint_flow_temperature | number.mixer_hc1_flowsettemp |
MM10 | mixer | 69 | pumpstatus | pump status (PC1) | boolean | True | switch.mixer_hc1_pump_status_(PC1) | switch.mixer_hc1_pumpstatus | |
MM10 | mixer | 69 | activated | activated | boolean | True | switch.mixer_hc1_activated | switch.mixer_hc1_activated | |
MM10 | mixer | 69 | valvesettime | time to set valve | uint8 (>=10<=120) | seconds | True | number.mixer_hc1_time_to_set_valve | number.mixer_hc1_valvesettime |
IPM | mixer | 100 | flowtemphc | flow temperature (TC1) | uint16 (>=0<=3199) | C | False | sensor.mixer_hc1_flow_temperature_(TC1) | sensor.mixer_hc1_flowtemphc |
IPM | mixer | 100 | valvestatus | mixing valve actuator (VC1) | uint8 (>=0<=100) | % | False | sensor.mixer_hc1_mixing_valve_actuator_(VC1) | sensor.mixer_hc1_valvestatus |
IPM | mixer | 100 | flowsettemp | setpoint flow temperature | uint8 (>=0<=254) | C | True | number.mixer_hc1_setpoint_flow_temperature | number.mixer_hc1_flowsettemp |
IPM | mixer | 100 | pumpstatus | pump status (PC1) | boolean | True | switch.mixer_hc1_pump_status_(PC1) | switch.mixer_hc1_pumpstatus | |
IPM | mixer | 100 | flowtempvf | flow temperature in header (T0/Vf) | uint16 (>=0<=3199) | C | False | sensor.mixer_hc1_flow_temperature_in_header_(T0/Vf) | sensor.mixer_hc1_flowtempvf |
IPM | mixer | 102 | flowtemphc | flow temperature (TC1) | uint16 (>=0<=3199) | C | False | sensor.mixer_hc1_flow_temperature_(TC1) | sensor.mixer_hc1_flowtemphc |
IPM | mixer | 102 | valvestatus | mixing valve actuator (VC1) | uint8 (>=0<=100) | % | False | sensor.mixer_hc1_mixing_valve_actuator_(VC1) | sensor.mixer_hc1_valvestatus |
IPM | mixer | 102 | flowsettemp | setpoint flow temperature | uint8 (>=0<=254) | C | True | number.mixer_hc1_setpoint_flow_temperature | number.mixer_hc1_flowsettemp |
IPM | mixer | 102 | pumpstatus | pump status (PC1) | boolean | True | switch.mixer_hc1_pump_status_(PC1) | switch.mixer_hc1_pumpstatus | |
IPM | mixer | 102 | flowtempvf | flow temperature in header (T0/Vf) | uint16 (>=0<=3199) | C | False | sensor.mixer_hc1_flow_temperature_in_header_(T0/Vf) | sensor.mixer_hc1_flowtempvf |
MM50 | mixer | 159 | flowtemphc | flow temperature (TC1) | uint16 (>=0<=3199) | C | False | sensor.mixer_hc1_flow_temperature_(TC1) | sensor.mixer_hc1_flowtemphc |
MM50 | mixer | 159 | valvestatus | mixing valve actuator (VC1) | uint8 (>=0<=100) | % | False | sensor.mixer_hc1_mixing_valve_actuator_(VC1) | sensor.mixer_hc1_valvestatus |
MM50 | mixer | 159 | flowsettemp | setpoint flow temperature | uint8 (>=0<=254) | C | True | number.mixer_hc1_setpoint_flow_temperature | number.mixer_hc1_flowsettemp |
MM50 | mixer | 159 | pumpstatus | pump status (PC1) | boolean | True | switch.mixer_hc1_pump_status_(PC1) | switch.mixer_hc1_pumpstatus | |
MM50 | mixer | 159 | activated | activated | boolean | True | switch.mixer_hc1_activated | switch.mixer_hc1_activated | |
MM50 | mixer | 159 | valvesettime | time to set valve | uint8 (>=10<=600) | seconds | True | number.mixer_hc1_time_to_set_valve | number.mixer_hc1_valvesettime |
MM50 | mixer | 159 | flowtempoffset | flow temperature offset for mixer | uint8 (>=0<=20) | K | True | number.mixer_hc1_flow_temperature_offset_for_mixer | number.mixer_hc1_flowtempoffset |
MM100 | mixer | 160 | flowtemphc | flow temperature (TC1) | uint16 (>=0<=3199) | C | False | sensor.mixer_dhw_flow_temperature_(TC1) | sensor.mixer_dhw_flowtemphc |
MM100 | mixer | 160 | valvestatus | mixing valve actuator (VC1) | uint8 (>=0<=100) | % | False | sensor.mixer_dhw_mixing_valve_actuator_(VC1) | sensor.mixer_dhw_valvestatus |
MM100 | mixer | 160 | flowsettemp | setpoint flow temperature | uint8 (>=0<=254) | C | True | number.mixer_dhw_setpoint_flow_temperature | number.mixer_dhw_flowsettemp |
MM100 | mixer | 160 | pumpstatus | pump status (PC1) | boolean | True | switch.mixer_dhw_pump_status_(PC1) | switch.mixer_dhw_pumpstatus | |
MM100 | mixer | 160 | activated | activated | boolean | True | switch.mixer_dhw_activated | switch.mixer_dhw_activated | |
MM100 | mixer | 160 | valvesettime | time to set valve | uint8 (>=10<=600) | seconds | True | number.mixer_dhw_time_to_set_valve | number.mixer_dhw_valvesettime |
MM100 | mixer | 160 | flowtempoffset | flow temperature offset for mixer | uint8 (>=0<=20) | K | True | number.mixer_dhw_flow_temperature_offset_for_mixer | number.mixer_dhw_flowtempoffset |
MM200 | mixer | 161 | flowtemphc | flow temperature (TC1) | uint16 (>=0<=3199) | C | False | sensor.mixer_hc1_flow_temperature_(TC1) | sensor.mixer_hc1_flowtemphc |
MM200 | mixer | 161 | valvestatus | mixing valve actuator (VC1) | uint8 (>=0<=100) | % | False | sensor.mixer_hc1_mixing_valve_actuator_(VC1) | sensor.mixer_hc1_valvestatus |
MM200 | mixer | 161 | flowsettemp | setpoint flow temperature | uint8 (>=0<=254) | C | True | number.mixer_hc1_setpoint_flow_temperature | number.mixer_hc1_flowsettemp |
MM200 | mixer | 161 | pumpstatus | pump status (PC1) | boolean | True | switch.mixer_hc1_pump_status_(PC1) | switch.mixer_hc1_pumpstatus | |
MM200 | mixer | 161 | activated | activated | boolean | True | switch.mixer_hc1_activated | switch.mixer_hc1_activated | |
MM200 | mixer | 161 | valvesettime | time to set valve | uint8 (>=10<=600) | seconds | True | number.mixer_hc1_time_to_set_valve | number.mixer_hc1_valvesettime |
MM200 | mixer | 161 | flowtempoffset | flow temperature offset for mixer | uint8 (>=0<=20) | K | True | number.mixer_hc1_flow_temperature_offset_for_mixer | number.mixer_hc1_flowtempoffset |
MZ100 | mixer | 193 | flowtemphc | flow temperature (TC1) | uint16 (>=0<=3199) | C | False | sensor.mixer_hc1_flow_temperature_(TC1) | sensor.mixer_hc1_flowtemphc |
MZ100 | mixer | 193 | valvestatus | mixing valve actuator (VC1) | uint8 (>=0<=100) | % | False | sensor.mixer_hc1_mixing_valve_actuator_(VC1) | sensor.mixer_hc1_valvestatus |
MZ100 | mixer | 193 | flowsettemp | setpoint flow temperature | uint8 (>=0<=254) | C | True | number.mixer_hc1_setpoint_flow_temperature | number.mixer_hc1_flowsettemp |
MZ100 | mixer | 193 | pumpstatus | pump status (PC1) | boolean | True | switch.mixer_hc1_pump_status_(PC1) | switch.mixer_hc1_pumpstatus | |
MZ100 | mixer | 193 | activated | activated | boolean | True | switch.mixer_hc1_activated | switch.mixer_hc1_activated | |
MZ100 | mixer | 193 | valvesettime | time to set valve | uint8 (>=10<=600) | seconds | True | number.mixer_hc1_time_to_set_valve | number.mixer_hc1_valvesettime |
MZ100 | mixer | 193 | flowtempoffset | flow temperature offset for mixer | uint8 (>=0<=20) | K | True | number.mixer_hc1_flow_temperature_offset_for_mixer | number.mixer_hc1_flowtempoffset |
SM10 | solar | 73 | collectortemp | collector temperature (TS1) | int16 (>=-3199<=3199) | C | False | sensor.solar_collector_temperature_(TS1) | sensor.solar_collectortemp |
SM10 | solar | 73 | cylbottomtemp | cylinder bottom temperature (TS2) | int16 (>=-3199<=3199) | C | False | sensor.solar_cylinder_bottom_temperature_(TS2) | sensor.solar_cylbottomtemp |
SM10 | solar | 73 | solarpump | pump (PS1) | boolean | False | binary_sensor.solar_pump_(PS1) | binary_sensor.solar_solarpump | |
SM10 | solar | 73 | pumpworktime | pump working time | time (>=0<=16777213) | minutes | False | sensor.solar_pump_working_time | sensor.solar_pumpworktime |
SM10 | solar | 73 | cylmaxtemp | maximum cylinder temperature | uint8 (>=0<=254) | C | True | number.solar_maximum_cylinder_temperature | number.solar_cylmaxtemp |
SM10 | solar | 73 | collectorshutdown | collector shutdown | boolean | False | binary_sensor.solar_collector_shutdown | binary_sensor.solar_collectorshutdown | |
SM10 | solar | 73 | cylheated | cyl heated | boolean | False | binary_sensor.solar_cyl_heated | binary_sensor.solar_cylheated | |
SM10 | solar | 73 | solarpumpmod | pump modulation (PS1) | uint8 (>=0<=100) | % | False | sensor.solar_pump_modulation_(PS1) | sensor.solar_solarpumpmod |
SM10 | solar | 73 | pumpminmod | minimum pump modulation | uint8 (>=0<=100) | % | True | number.solar_minimum_pump_modulation | number.solar_pumpminmod |
SM10 | solar | 73 | turnondiff | pump turn on difference | uint8 (>=0<=254) | C | True | number.solar_pump_turn_on_difference | number.solar_turnondiff |
SM10 | solar | 73 | turnoffdiff | pump turn off difference | uint8 (>=0<=254) | C | True | number.solar_pump_turn_off_difference | number.solar_turnoffdiff |
SM10 | solar | 73 | solarpower | actual solar power | int16 (>=-31999<=31999) | W | False | sensor.solar_actual_solar_power | sensor.solar_solarpower |
SM10 | solar | 73 | energylasthour | energy last hour | uint24 (>=0<=1677721) | Wh | False | sensor.solar_energy_last_hour | sensor.solar_energylasthour |
SM10 | solar | 73 | maxflow | maximum solar flow | uint8 (>=0<=25) | l/min | True | number.solar_maximum_solar_flow | number.solar_maxflow |
SM10 | solar | 73 | mintemp | minimum temperature | uint8 (>=0<=254) | C | True | number.solar_dhw_minimum_temperature | number.solar_dhw_mintemp |
SM10 | solar | 73 | solarenabled | solarmodule enabled | boolean | True | switch.solar_solarmodule_enabled | switch.solar_solarenabled | |
ISM1 | solar | 101 | collectortemp | collector temperature (TS1) | int16 (>=-3199<=3199) | C | False | sensor.solar_collector_temperature_(TS1) | sensor.solar_collectortemp |
ISM1 | solar | 101 | cylbottomtemp | cylinder bottom temperature (TS2) | int16 (>=-3199<=3199) | C | False | sensor.solar_cylinder_bottom_temperature_(TS2) | sensor.solar_cylbottomtemp |
ISM1 | solar | 101 | solarpump | pump (PS1) | boolean | False | binary_sensor.solar_pump_(PS1) | binary_sensor.solar_solarpump | |
ISM1 | solar | 101 | pumpworktime | pump working time | time (>=0<=16777213) | minutes | False | sensor.solar_pump_working_time | sensor.solar_pumpworktime |
ISM1 | solar | 101 | cylmaxtemp | maximum cylinder temperature | uint8 (>=0<=254) | C | True | number.solar_maximum_cylinder_temperature | number.solar_cylmaxtemp |
ISM1 | solar | 101 | collectorshutdown | collector shutdown | boolean | False | binary_sensor.solar_collector_shutdown | binary_sensor.solar_collectorshutdown | |
ISM1 | solar | 101 | cylheated | cyl heated | boolean | False | binary_sensor.solar_cyl_heated | binary_sensor.solar_cylheated | |
ISM1 | solar | 101 | cylmiddletemp | cylinder middle temperature (TS3) | int16 (>=-3199<=3199) | C | False | sensor.solar_cylinder_middle_temperature_(TS3) | sensor.solar_cylmiddletemp |
ISM1 | solar | 101 | retheatassist | return temperature heat assistance (TS4) | int16 (>=-3199<=3199) | C | False | sensor.solar_return_temperature_heat_assistance_(TS4) | sensor.solar_retheatassist |
ISM1 | solar | 101 | heatassistvalve | heat assistance valve (M1) | boolean | False | binary_sensor.solar_heat_assistance_valve_(M1) | binary_sensor.solar_heatassistvalve | |
ISM1 | solar | 101 | energylasthour | energy last hour | uint24 (>=0<=1677721) | Wh | False | sensor.solar_energy_last_hour | sensor.solar_energylasthour |
ISM2 | solar | 103 | collectortemp | collector temperature (TS1) | int16 (>=-3199<=3199) | C | False | sensor.solar_collector_temperature_(TS1) | sensor.solar_collectortemp |
ISM2 | solar | 103 | cylbottomtemp | cylinder bottom temperature (TS2) | int16 (>=-3199<=3199) | C | False | sensor.solar_cylinder_bottom_temperature_(TS2) | sensor.solar_cylbottomtemp |
ISM2 | solar | 103 | solarpump | pump (PS1) | boolean | False | binary_sensor.solar_pump_(PS1) | binary_sensor.solar_solarpump | |
ISM2 | solar | 103 | pumpworktime | pump working time | time (>=0<=16777213) | minutes | False | sensor.solar_pump_working_time | sensor.solar_pumpworktime |
ISM2 | solar | 103 | cylmaxtemp | maximum cylinder temperature | uint8 (>=0<=254) | C | True | number.solar_maximum_cylinder_temperature | number.solar_cylmaxtemp |
ISM2 | solar | 103 | collectorshutdown | collector shutdown | boolean | False | binary_sensor.solar_collector_shutdown | binary_sensor.solar_collectorshutdown | |
ISM2 | solar | 103 | cylheated | cyl heated | boolean | False | binary_sensor.solar_cyl_heated | binary_sensor.solar_cylheated | |
ISM2 | solar | 103 | cylmiddletemp | cylinder middle temperature (TS3) | int16 (>=-3199<=3199) | C | False | sensor.solar_cylinder_middle_temperature_(TS3) | sensor.solar_cylmiddletemp |
ISM2 | solar | 103 | retheatassist | return temperature heat assistance (TS4) | int16 (>=-3199<=3199) | C | False | sensor.solar_return_temperature_heat_assistance_(TS4) | sensor.solar_retheatassist |
ISM2 | solar | 103 | heatassistvalve | heat assistance valve (M1) | boolean | False | binary_sensor.solar_heat_assistance_valve_(M1) | binary_sensor.solar_heatassistvalve | |
ISM2 | solar | 103 | energylasthour | energy last hour | uint24 (>=0<=1677721) | Wh | False | sensor.solar_energy_last_hour | sensor.solar_energylasthour |
SM50 | solar | 162 | collectortemp | collector temperature (TS1) | int16 (>=-3199<=3199) | C | False | sensor.solar_collector_temperature_(TS1) | sensor.solar_collectortemp |
SM50 | solar | 162 | cylbottomtemp | cylinder bottom temperature (TS2) | int16 (>=-3199<=3199) | C | False | sensor.solar_cylinder_bottom_temperature_(TS2) | sensor.solar_cylbottomtemp |
SM50 | solar | 162 | solarpump | pump (PS1) | boolean | False | binary_sensor.solar_pump_(PS1) | binary_sensor.solar_solarpump | |
SM50 | solar | 162 | pumpworktime | pump working time | time (>=0<=16777213) | minutes | False | sensor.solar_pump_working_time | sensor.solar_pumpworktime |
SM50 | solar | 162 | cylmaxtemp | maximum cylinder temperature | uint8 (>=0<=254) | C | True | number.solar_maximum_cylinder_temperature | number.solar_cylmaxtemp |
SM50 | solar | 162 | collectorshutdown | collector shutdown | boolean | False | binary_sensor.solar_collector_shutdown | binary_sensor.solar_collectorshutdown | |
SM50 | solar | 162 | cylheated | cyl heated | boolean | False | binary_sensor.solar_cyl_heated | binary_sensor.solar_cylheated | |
SM50 | solar | 162 | solarpumpmod | pump modulation (PS1) | uint8 (>=0<=100) | % | False | sensor.solar_pump_modulation_(PS1) | sensor.solar_solarpumpmod |
SM50 | solar | 162 | pumpminmod | minimum pump modulation | uint8 (>=0<=100) | % | True | number.solar_minimum_pump_modulation | number.solar_pumpminmod |
SM50 | solar | 162 | turnondiff | pump turn on difference | uint8 (>=0<=25) | C | True | number.solar_pump_turn_on_difference | number.solar_turnondiff |
SM50 | solar | 162 | turnoffdiff | pump turn off difference | uint8 (>=0<=25) | C | True | number.solar_pump_turn_off_difference | number.solar_turnoffdiff |
SM50 | solar | 162 | collector2temp | collector 2 temperature (TS7) | int16 (>=-3199<=3199) | C | False | sensor.solar_collector_2_temperature_(TS7) | sensor.solar_collector2temp |
SM50 | solar | 162 | cylmiddletemp | cylinder middle temperature (TS3) | int16 (>=-3199<=3199) | C | False | sensor.solar_cylinder_middle_temperature_(TS3) | sensor.solar_cylmiddletemp |
SM50 | solar | 162 | retheatassist | return temperature heat assistance (TS4) | int16 (>=-3199<=3199) | C | False | sensor.solar_return_temperature_heat_assistance_(TS4) | sensor.solar_retheatassist |
SM50 | solar | 162 | heatassistvalve | heat assistance valve (M1) | boolean | False | binary_sensor.solar_heat_assistance_valve_(M1) | binary_sensor.solar_heatassistvalve | |
SM50 | solar | 162 | heatassistpower | heat assistance valve power (M1) | uint8 (>=0<=100) | % | False | sensor.solar_heat_assistance_valve_power_(M1) | sensor.solar_heatassistpower |
SM50 | solar | 162 | solarpump2 | pump 2 (PS4) | boolean | False | binary_sensor.solar_pump_2_(PS4) | binary_sensor.solar_solarpump2 | |
SM50 | solar | 162 | solarpump2mod | pump 2 modulation (PS4) | uint8 (>=0<=100) | % | False | sensor.solar_pump_2_modulation_(PS4) | sensor.solar_solarpump2mod |
SM50 | solar | 162 | cyl2bottomtemp | second cylinder bottom temperature (TS5) | int16 (>=-3199<=3199) | C | False | sensor.solar_second_cylinder_bottom_temperature_(TS5) | sensor.solar_cyl2bottomtemp |
SM50 | solar | 162 | heatexchangertemp | heat exchanger temperature (TS6) | int16 (>=-3199<=3199) | C | False | sensor.solar_heat_exchanger_temperature_(TS6) | sensor.solar_heatexchangertemp |
SM50 | solar | 162 | cylpumpmod | cylinder pump modulation (PS5) | uint8 (>=0<=100) | % | False | sensor.solar_cylinder_pump_modulation_(PS5) | sensor.solar_cylpumpmod |
SM50 | solar | 162 | valvestatus | valve status | boolean | False | binary_sensor.solar_valve_status | binary_sensor.solar_valvestatus | |
SM50 | solar | 162 | vs1status | valve status VS1 | boolean | False | binary_sensor.solar_valve_status_VS1 | binary_sensor.solar_vs1status | |
SM50 | solar | 162 | collectormaxtemp | maximum collector temperature | uint8 (>=0<=254) | C | True | number.solar_maximum_collector_temperature | number.solar_collectormaxtemp |
SM50 | solar | 162 | collectormintemp | minimum collector temperature | uint8 (>=0<=254) | C | True | number.solar_minimum_collector_temperature | number.solar_collectormintemp |
SM50 | solar | 162 | energylasthour | energy last hour | uint24 (>=0<=1677721) | Wh | False | sensor.solar_energy_last_hour | sensor.solar_energylasthour |
SM50 | solar | 162 | energytoday | total energy today | uint24 (>=0<=16777213) | Wh | False | sensor.solar_total_energy_today | sensor.solar_energytoday |
SM50 | solar | 162 | energytotal | total energy | uint24 (>=0<=1677721) | kWh | False | sensor.solar_total_energy | sensor.solar_energytotal |
SM50 | solar | 162 | pump2worktime | pump 2 working time | time (>=0<=16777213) | minutes | False | sensor.solar_pump_2_working_time | sensor.solar_pump2worktime |
SM50 | solar | 162 | m1worktime | differential control working time | time (>=0<=16777213) | minutes | False | sensor.solar_differential_control_working_time | sensor.solar_m1worktime |
SM50 | solar | 162 | heattransfersystem | heattransfer system | boolean | True | switch.solar_heattransfer_system | switch.solar_heattransfersystem | |
SM50 | solar | 162 | externalcyl | external cylinder | boolean | True | switch.solar_external_cylinder | switch.solar_externalcyl | |
SM50 | solar | 162 | thermaldisinfect | thermal disinfection | boolean | True | switch.solar_thermal_disinfection | switch.solar_thermaldisinfect | |
SM50 | solar | 162 | heatmetering | heatmetering | boolean | True | switch.solar_heatmetering | switch.solar_heatmetering | |
SM50 | solar | 162 | activated | activated | boolean | True | switch.solar_activated | switch.solar_activated | |
SM50 | solar | 162 | solarpumpmode | pump mode | enum [constant|pwm|analog] | True | select.solar_pump_mode | select.solar_solarpumpmode | |
SM50 | solar | 162 | pumpkick | pump kick | boolean | True | switch.solar_pump_kick | switch.solar_pumpkick | |
SM50 | solar | 162 | plainwatermode | plain water mode | boolean | True | switch.solar_plain_water_mode | switch.solar_plainwatermode | |
SM50 | solar | 162 | doublematchflow | doublematchflow | boolean | True | switch.solar_doublematchflow | switch.solar_doublematchflow | |
SM50 | solar | 162 | pump2minmod | minimum pump 2 modulation | uint8 (>=0<=100) | % | True | number.solar_minimum_pump_2_modulation | number.solar_pump2minmod |
SM50 | solar | 162 | turnondiff2 | pump 2 turn on difference | uint8 (>=0<=25) | C | True | number.solar_pump_2_turn_on_difference | number.solar_turnondiff2 |
SM50 | solar | 162 | turnoffdiff2 | pump 2 turn off difference | uint8 (>=0<=25) | C | True | number.solar_pump_2_turn_off_difference | number.solar_turnoffdiff2 |
SM50 | solar | 162 | pump2kick | pump kick 2 | boolean | True | switch.solar_pump_kick_2 | switch.solar_pump2kick | |
SM50 | solar | 162 | climatezone | climate zone | uint8 (>=0<=254) | True | number.solar_climate_zone | number.solar_climatezone | |
SM50 | solar | 162 | collector1area | collector 1 area | uint16 (>=0<=3199) | m² | True | number.solar_collector_1_area | number.solar_collector1area |
SM50 | solar | 162 | collector1type | collector 1 type | enum [flat|vacuum] | True | select.solar_collector_1_type | select.solar_collector1type | |
SM50 | solar | 162 | collector2area | collector 2 area | uint16 (>=0<=3199) | m² | True | number.solar_collector_2_area | number.solar_collector2area |
SM50 | solar | 162 | collector2type | collector 2 type | enum [flat|vacuum] | True | select.solar_collector_2_type | select.solar_collector2type | |
SM50 | solar | 162 | cylpriority | cylinder priority | enum [cyl 1|cyl 2] | True | select.solar_cylinder_priority | select.solar_cylpriority | |
SM50 | solar | 162 | heatcntflowtemp | heat counter flow temperature | uint16 (>=0<=3199) | C | False | sensor.solar_heat_counter_flow_temperature | sensor.solar_heatcntflowtemp |
SM50 | solar | 162 | heatcntrettemp | heat counter return temperature | uint16 (>=0<=3199) | C | False | sensor.solar_heat_counter_return_temperature | sensor.solar_heatcntrettemp |
SM50 | solar | 162 | heatcnt | heat counter impulses | uint8 (>=0<=254) | False | sensor.solar_heat_counter_impulses | sensor.solar_heatcnt | |
SM50 | solar | 162 | swapflowtemp | swap flow temperature (TS14) | uint16 (>=0<=3199) | C | False | sensor.solar_swap_flow_temperature_(TS14) | sensor.solar_swapflowtemp |
SM50 | solar | 162 | swaprettemp | swap return temperature (TS15) | uint16 (>=0<=3199) | C | False | sensor.solar_swap_return_temperature_(TS15) | sensor.solar_swaprettemp |
SM100/MS100 | solar | 163 | collectortemp | collector temperature (TS1) | int16 (>=-3199<=3199) | C | False | sensor.solar_collector_temperature_(TS1) | sensor.solar_collectortemp |
SM100/MS100 | solar | 163 | cylbottomtemp | cylinder bottom temperature (TS2) | int16 (>=-3199<=3199) | C | False | sensor.solar_cylinder_bottom_temperature_(TS2) | sensor.solar_cylbottomtemp |
SM100/MS100 | solar | 163 | solarpump | pump (PS1) | boolean | False | binary_sensor.solar_pump_(PS1) | binary_sensor.solar_solarpump | |
SM100/MS100 | solar | 163 | pumpworktime | pump working time | time (>=0<=16777213) | minutes | False | sensor.solar_pump_working_time | sensor.solar_pumpworktime |
SM100/MS100 | solar | 163 | cylmaxtemp | maximum cylinder temperature | uint8 (>=0<=254) | C | True | number.solar_maximum_cylinder_temperature | number.solar_cylmaxtemp |
SM100/MS100 | solar | 163 | collectorshutdown | collector shutdown | boolean | False | binary_sensor.solar_collector_shutdown | binary_sensor.solar_collectorshutdown | |
SM100/MS100 | solar | 163 | cylheated | cyl heated | boolean | False | binary_sensor.solar_cyl_heated | binary_sensor.solar_cylheated | |
SM100/MS100 | solar | 163 | solarpumpmod | pump modulation (PS1) | uint8 (>=0<=100) | % | False | sensor.solar_pump_modulation_(PS1) | sensor.solar_solarpumpmod |
SM100/MS100 | solar | 163 | pumpminmod | minimum pump modulation | uint8 (>=0<=100) | % | True | number.solar_minimum_pump_modulation | number.solar_pumpminmod |
SM100/MS100 | solar | 163 | turnondiff | pump turn on difference | uint8 (>=0<=25) | C | True | number.solar_pump_turn_on_difference | number.solar_turnondiff |
SM100/MS100 | solar | 163 | turnoffdiff | pump turn off difference | uint8 (>=0<=25) | C | True | number.solar_pump_turn_off_difference | number.solar_turnoffdiff |
SM100/MS100 | solar | 163 | collector2temp | collector 2 temperature (TS7) | int16 (>=-3199<=3199) | C | False | sensor.solar_collector_2_temperature_(TS7) | sensor.solar_collector2temp |
SM100/MS100 | solar | 163 | cylmiddletemp | cylinder middle temperature (TS3) | int16 (>=-3199<=3199) | C | False | sensor.solar_cylinder_middle_temperature_(TS3) | sensor.solar_cylmiddletemp |
SM100/MS100 | solar | 163 | retheatassist | return temperature heat assistance (TS4) | int16 (>=-3199<=3199) | C | False | sensor.solar_return_temperature_heat_assistance_(TS4) | sensor.solar_retheatassist |
SM100/MS100 | solar | 163 | heatassistvalve | heat assistance valve (M1) | boolean | False | binary_sensor.solar_heat_assistance_valve_(M1) | binary_sensor.solar_heatassistvalve | |
SM100/MS100 | solar | 163 | heatassistpower | heat assistance valve power (M1) | uint8 (>=0<=100) | % | False | sensor.solar_heat_assistance_valve_power_(M1) | sensor.solar_heatassistpower |
SM100/MS100 | solar | 163 | solarpump2 | pump 2 (PS4) | boolean | False | binary_sensor.solar_pump_2_(PS4) | binary_sensor.solar_solarpump2 | |
SM100/MS100 | solar | 163 | solarpump2mod | pump 2 modulation (PS4) | uint8 (>=0<=100) | % | False | sensor.solar_pump_2_modulation_(PS4) | sensor.solar_solarpump2mod |
SM100/MS100 | solar | 163 | cyl2bottomtemp | second cylinder bottom temperature (TS5) | int16 (>=-3199<=3199) | C | False | sensor.solar_second_cylinder_bottom_temperature_(TS5) | sensor.solar_cyl2bottomtemp |
SM100/MS100 | solar | 163 | heatexchangertemp | heat exchanger temperature (TS6) | int16 (>=-3199<=3199) | C | False | sensor.solar_heat_exchanger_temperature_(TS6) | sensor.solar_heatexchangertemp |
SM100/MS100 | solar | 163 | cylpumpmod | cylinder pump modulation (PS5) | uint8 (>=0<=100) | % | False | sensor.solar_cylinder_pump_modulation_(PS5) | sensor.solar_cylpumpmod |
SM100/MS100 | solar | 163 | valvestatus | valve status | boolean | False | binary_sensor.solar_valve_status | binary_sensor.solar_valvestatus | |
SM100/MS100 | solar | 163 | vs1status | valve status VS1 | boolean | False | binary_sensor.solar_valve_status_VS1 | binary_sensor.solar_vs1status | |
SM100/MS100 | solar | 163 | collectormaxtemp | maximum collector temperature | uint8 (>=0<=254) | C | True | number.solar_maximum_collector_temperature | number.solar_collectormaxtemp |
SM100/MS100 | solar | 163 | collectormintemp | minimum collector temperature | uint8 (>=0<=254) | C | True | number.solar_minimum_collector_temperature | number.solar_collectormintemp |
SM100/MS100 | solar | 163 | energylasthour | energy last hour | uint24 (>=0<=1677721) | Wh | False | sensor.solar_energy_last_hour | sensor.solar_energylasthour |
SM100/MS100 | solar | 163 | energytoday | total energy today | uint24 (>=0<=16777213) | Wh | False | sensor.solar_total_energy_today | sensor.solar_energytoday |
SM100/MS100 | solar | 163 | energytotal | total energy | uint24 (>=0<=1677721) | kWh | False | sensor.solar_total_energy | sensor.solar_energytotal |
SM100/MS100 | solar | 163 | pump2worktime | pump 2 working time | time (>=0<=16777213) | minutes | False | sensor.solar_pump_2_working_time | sensor.solar_pump2worktime |
SM100/MS100 | solar | 163 | m1worktime | differential control working time | time (>=0<=16777213) | minutes | False | sensor.solar_differential_control_working_time | sensor.solar_m1worktime |
SM100/MS100 | solar | 163 | heattransfersystem | heattransfer system | boolean | True | switch.solar_heattransfer_system | switch.solar_heattransfersystem | |
SM100/MS100 | solar | 163 | externalcyl | external cylinder | boolean | True | switch.solar_external_cylinder | switch.solar_externalcyl | |
SM100/MS100 | solar | 163 | thermaldisinfect | thermal disinfection | boolean | True | switch.solar_thermal_disinfection | switch.solar_thermaldisinfect | |
SM100/MS100 | solar | 163 | heatmetering | heatmetering | boolean | True | switch.solar_heatmetering | switch.solar_heatmetering | |
SM100/MS100 | solar | 163 | activated | activated | boolean | True | switch.solar_activated | switch.solar_activated | |
SM100/MS100 | solar | 163 | solarpumpmode | pump mode | enum [constant|pwm|analog] | True | select.solar_pump_mode | select.solar_solarpumpmode | |
SM100/MS100 | solar | 163 | pumpkick | pump kick | boolean | True | switch.solar_pump_kick | switch.solar_pumpkick | |
SM100/MS100 | solar | 163 | plainwatermode | plain water mode | boolean | True | switch.solar_plain_water_mode | switch.solar_plainwatermode | |
SM100/MS100 | solar | 163 | doublematchflow | doublematchflow | boolean | True | switch.solar_doublematchflow | switch.solar_doublematchflow | |
SM100/MS100 | solar | 163 | pump2minmod | minimum pump 2 modulation | uint8 (>=0<=100) | % | True | number.solar_minimum_pump_2_modulation | number.solar_pump2minmod |
SM100/MS100 | solar | 163 | turnondiff2 | pump 2 turn on difference | uint8 (>=0<=25) | C | True | number.solar_pump_2_turn_on_difference | number.solar_turnondiff2 |
SM100/MS100 | solar | 163 | turnoffdiff2 | pump 2 turn off difference | uint8 (>=0<=25) | C | True | number.solar_pump_2_turn_off_difference | number.solar_turnoffdiff2 |
SM100/MS100 | solar | 163 | pump2kick | pump kick 2 | boolean | True | switch.solar_pump_kick_2 | switch.solar_pump2kick | |
SM100/MS100 | solar | 163 | climatezone | climate zone | uint8 (>=0<=254) | True | number.solar_climate_zone | number.solar_climatezone | |
SM100/MS100 | solar | 163 | collector1area | collector 1 area | uint16 (>=0<=3199) | m² | True | number.solar_collector_1_area | number.solar_collector1area |
SM100/MS100 | solar | 163 | collector1type | collector 1 type | enum [flat|vacuum] | True | select.solar_collector_1_type | select.solar_collector1type | |
SM100/MS100 | solar | 163 | collector2area | collector 2 area | uint16 (>=0<=3199) | m² | True | number.solar_collector_2_area | number.solar_collector2area |
SM100/MS100 | solar | 163 | collector2type | collector 2 type | enum [flat|vacuum] | True | select.solar_collector_2_type | select.solar_collector2type | |
SM100/MS100 | solar | 163 | cylpriority | cylinder priority | enum [cyl 1|cyl 2] | True | select.solar_cylinder_priority | select.solar_cylpriority | |
SM100/MS100 | solar | 163 | heatcntflowtemp | heat counter flow temperature | uint16 (>=0<=3199) | C | False | sensor.solar_heat_counter_flow_temperature | sensor.solar_heatcntflowtemp |
SM100/MS100 | solar | 163 | heatcntrettemp | heat counter return temperature | uint16 (>=0<=3199) | C | False | sensor.solar_heat_counter_return_temperature | sensor.solar_heatcntrettemp |
SM100/MS100 | solar | 163 | heatcnt | heat counter impulses | uint8 (>=0<=254) | False | sensor.solar_heat_counter_impulses | sensor.solar_heatcnt | |
SM100/MS100 | solar | 163 | swapflowtemp | swap flow temperature (TS14) | uint16 (>=0<=3199) | C | False | sensor.solar_swap_flow_temperature_(TS14) | sensor.solar_swapflowtemp |
SM100/MS100 | solar | 163 | swaprettemp | swap return temperature (TS15) | uint16 (>=0<=3199) | C | False | sensor.solar_swap_return_temperature_(TS15) | sensor.solar_swaprettemp |
SM200/MS200 | solar | 164 | collectortemp | collector temperature (TS1) | int16 (>=-3199<=3199) | C | False | sensor.solar_collector_temperature_(TS1) | sensor.solar_collectortemp |
SM200/MS200 | solar | 164 | cylbottomtemp | cylinder bottom temperature (TS2) | int16 (>=-3199<=3199) | C | False | sensor.solar_cylinder_bottom_temperature_(TS2) | sensor.solar_cylbottomtemp |
SM200/MS200 | solar | 164 | solarpump | pump (PS1) | boolean | False | binary_sensor.solar_pump_(PS1) | binary_sensor.solar_solarpump | |
SM200/MS200 | solar | 164 | pumpworktime | pump working time | time (>=0<=16777213) | minutes | False | sensor.solar_pump_working_time | sensor.solar_pumpworktime |
SM200/MS200 | solar | 164 | cylmaxtemp | maximum cylinder temperature | uint8 (>=0<=254) | C | True | number.solar_maximum_cylinder_temperature | number.solar_cylmaxtemp |
SM200/MS200 | solar | 164 | collectorshutdown | collector shutdown | boolean | False | binary_sensor.solar_collector_shutdown | binary_sensor.solar_collectorshutdown | |
SM200/MS200 | solar | 164 | cylheated | cyl heated | boolean | False | binary_sensor.solar_cyl_heated | binary_sensor.solar_cylheated | |
SM200/MS200 | solar | 164 | solarpumpmod | pump modulation (PS1) | uint8 (>=0<=100) | % | False | sensor.solar_pump_modulation_(PS1) | sensor.solar_solarpumpmod |
SM200/MS200 | solar | 164 | pumpminmod | minimum pump modulation | uint8 (>=0<=100) | % | True | number.solar_minimum_pump_modulation | number.solar_pumpminmod |
SM200/MS200 | solar | 164 | turnondiff | pump turn on difference | uint8 (>=0<=25) | C | True | number.solar_pump_turn_on_difference | number.solar_turnondiff |
SM200/MS200 | solar | 164 | turnoffdiff | pump turn off difference | uint8 (>=0<=25) | C | True | number.solar_pump_turn_off_difference | number.solar_turnoffdiff |
SM200/MS200 | solar | 164 | collector2temp | collector 2 temperature (TS7) | int16 (>=-3199<=3199) | C | False | sensor.solar_collector_2_temperature_(TS7) | sensor.solar_collector2temp |
SM200/MS200 | solar | 164 | cylmiddletemp | cylinder middle temperature (TS3) | int16 (>=-3199<=3199) | C | False | sensor.solar_cylinder_middle_temperature_(TS3) | sensor.solar_cylmiddletemp |
SM200/MS200 | solar | 164 | retheatassist | return temperature heat assistance (TS4) | int16 (>=-3199<=3199) | C | False | sensor.solar_return_temperature_heat_assistance_(TS4) | sensor.solar_retheatassist |
SM200/MS200 | solar | 164 | heatassistvalve | heat assistance valve (M1) | boolean | False | binary_sensor.solar_heat_assistance_valve_(M1) | binary_sensor.solar_heatassistvalve | |
SM200/MS200 | solar | 164 | heatassistpower | heat assistance valve power (M1) | uint8 (>=0<=100) | % | False | sensor.solar_heat_assistance_valve_power_(M1) | sensor.solar_heatassistpower |
SM200/MS200 | solar | 164 | solarpump2 | pump 2 (PS4) | boolean | False | binary_sensor.solar_pump_2_(PS4) | binary_sensor.solar_solarpump2 | |
SM200/MS200 | solar | 164 | solarpump2mod | pump 2 modulation (PS4) | uint8 (>=0<=100) | % | False | sensor.solar_pump_2_modulation_(PS4) | sensor.solar_solarpump2mod |
SM200/MS200 | solar | 164 | cyl2bottomtemp | second cylinder bottom temperature (TS5) | int16 (>=-3199<=3199) | C | False | sensor.solar_second_cylinder_bottom_temperature_(TS5) | sensor.solar_cyl2bottomtemp |
SM200/MS200 | solar | 164 | heatexchangertemp | heat exchanger temperature (TS6) | int16 (>=-3199<=3199) | C | False | sensor.solar_heat_exchanger_temperature_(TS6) | sensor.solar_heatexchangertemp |
SM200/MS200 | solar | 164 | cylpumpmod | cylinder pump modulation (PS5) | uint8 (>=0<=100) | % | False | sensor.solar_cylinder_pump_modulation_(PS5) | sensor.solar_cylpumpmod |
SM200/MS200 | solar | 164 | valvestatus | valve status | boolean | False | binary_sensor.solar_valve_status | binary_sensor.solar_valvestatus | |
SM200/MS200 | solar | 164 | vs1status | valve status VS1 | boolean | False | binary_sensor.solar_valve_status_VS1 | binary_sensor.solar_vs1status | |
SM200/MS200 | solar | 164 | collectormaxtemp | maximum collector temperature | uint8 (>=0<=254) | C | True | number.solar_maximum_collector_temperature | number.solar_collectormaxtemp |
SM200/MS200 | solar | 164 | collectormintemp | minimum collector temperature | uint8 (>=0<=254) | C | True | number.solar_minimum_collector_temperature | number.solar_collectormintemp |
SM200/MS200 | solar | 164 | energylasthour | energy last hour | uint24 (>=0<=1677721) | Wh | False | sensor.solar_energy_last_hour | sensor.solar_energylasthour |
SM200/MS200 | solar | 164 | energytoday | total energy today | uint24 (>=0<=16777213) | Wh | False | sensor.solar_total_energy_today | sensor.solar_energytoday |
SM200/MS200 | solar | 164 | energytotal | total energy | uint24 (>=0<=1677721) | kWh | False | sensor.solar_total_energy | sensor.solar_energytotal |
SM200/MS200 | solar | 164 | pump2worktime | pump 2 working time | time (>=0<=16777213) | minutes | False | sensor.solar_pump_2_working_time | sensor.solar_pump2worktime |
SM200/MS200 | solar | 164 | m1worktime | differential control working time | time (>=0<=16777213) | minutes | False | sensor.solar_differential_control_working_time | sensor.solar_m1worktime |
SM200/MS200 | solar | 164 | heattransfersystem | heattransfer system | boolean | True | switch.solar_heattransfer_system | switch.solar_heattransfersystem | |
SM200/MS200 | solar | 164 | externalcyl | external cylinder | boolean | True | switch.solar_external_cylinder | switch.solar_externalcyl | |
SM200/MS200 | solar | 164 | thermaldisinfect | thermal disinfection | boolean | True | switch.solar_thermal_disinfection | switch.solar_thermaldisinfect | |
SM200/MS200 | solar | 164 | heatmetering | heatmetering | boolean | True | switch.solar_heatmetering | switch.solar_heatmetering | |
SM200/MS200 | solar | 164 | activated | activated | boolean | True | switch.solar_activated | switch.solar_activated | |
SM200/MS200 | solar | 164 | solarpumpmode | pump mode | enum [constant|pwm|analog] | True | select.solar_pump_mode | select.solar_solarpumpmode | |
SM200/MS200 | solar | 164 | pumpkick | pump kick | boolean | True | switch.solar_pump_kick | switch.solar_pumpkick | |
SM200/MS200 | solar | 164 | plainwatermode | plain water mode | boolean | True | switch.solar_plain_water_mode | switch.solar_plainwatermode | |
SM200/MS200 | solar | 164 | doublematchflow | doublematchflow | boolean | True | switch.solar_doublematchflow | switch.solar_doublematchflow | |
SM200/MS200 | solar | 164 | pump2minmod | minimum pump 2 modulation | uint8 (>=0<=100) | % | True | number.solar_minimum_pump_2_modulation | number.solar_pump2minmod |
SM200/MS200 | solar | 164 | turnondiff2 | pump 2 turn on difference | uint8 (>=0<=25) | C | True | number.solar_pump_2_turn_on_difference | number.solar_turnondiff2 |
SM200/MS200 | solar | 164 | turnoffdiff2 | pump 2 turn off difference | uint8 (>=0<=25) | C | True | number.solar_pump_2_turn_off_difference | number.solar_turnoffdiff2 |
SM200/MS200 | solar | 164 | pump2kick | pump kick 2 | boolean | True | switch.solar_pump_kick_2 | switch.solar_pump2kick | |
SM200/MS200 | solar | 164 | climatezone | climate zone | uint8 (>=0<=254) | True | number.solar_climate_zone | number.solar_climatezone | |
SM200/MS200 | solar | 164 | collector1area | collector 1 area | uint16 (>=0<=3199) | m² | True | number.solar_collector_1_area | number.solar_collector1area |
SM200/MS200 | solar | 164 | collector1type | collector 1 type | enum [flat|vacuum] | True | select.solar_collector_1_type | select.solar_collector1type | |
SM200/MS200 | solar | 164 | collector2area | collector 2 area | uint16 (>=0<=3199) | m² | True | number.solar_collector_2_area | number.solar_collector2area |
SM200/MS200 | solar | 164 | collector2type | collector 2 type | enum [flat|vacuum] | True | select.solar_collector_2_type | select.solar_collector2type | |
SM200/MS200 | solar | 164 | cylpriority | cylinder priority | enum [cyl 1|cyl 2] | True | select.solar_cylinder_priority | select.solar_cylpriority | |
SM200/MS200 | solar | 164 | heatcntflowtemp | heat counter flow temperature | uint16 (>=0<=3199) | C | False | sensor.solar_heat_counter_flow_temperature | sensor.solar_heatcntflowtemp |
SM200/MS200 | solar | 164 | heatcntrettemp | heat counter return temperature | uint16 (>=0<=3199) | C | False | sensor.solar_heat_counter_return_temperature | sensor.solar_heatcntrettemp |
SM200/MS200 | solar | 164 | heatcnt | heat counter impulses | uint8 (>=0<=254) | False | sensor.solar_heat_counter_impulses | sensor.solar_heatcnt | |
SM200/MS200 | solar | 164 | swapflowtemp | swap flow temperature (TS14) | uint16 (>=0<=3199) | C | False | sensor.solar_swap_flow_temperature_(TS14) | sensor.solar_swapflowtemp |
SM200/MS200 | solar | 164 | swaprettemp | swap return temperature (TS15) | uint16 (>=0<=3199) | C | False | sensor.solar_swap_return_temperature_(TS15) | sensor.solar_swaprettemp |
HP Module | heatpump | 252 | airhumidity | relative air humidity | uint8 (>=0<=100) | % | False | sensor.heatpump_relative_air_humidity | sensor.heatpump_airhumidity |
HP Module | heatpump | 252 | dewtemperature | dew point temperature | uint8 (>=0<=254) | C | False | sensor.heatpump_dew_point_temperature | sensor.heatpump_dewtemperature |
HP Module | heatpump | 252 | curflowtemp | current flow temperature | int16 (>=-3199<=3199) | C | False | sensor.heatpump_current_flow_temperature | sensor.heatpump_curflowtemp |
HP Module | heatpump | 252 | rettemp | return temperature | int16 (>=-3199<=3199) | C | False | sensor.heatpump_return_temperature | sensor.heatpump_rettemp |
HP Module | heatpump | 252 | sysrettemp | system return temperature | int16 (>=-3199<=3199) | C | False | sensor.heatpump_system_return_temperature | sensor.heatpump_sysrettemp |
HP Module | heatpump | 252 | hpta4 | drain pan temp (TA4) | int16 (>=-3199<=3199) | C | False | sensor.heatpump_drain_pan_temp_(TA4) | sensor.heatpump_hpta4 |
HP Module | heatpump | 252 | hptr1 | compressor temperature (TR1) | int16 (>=-3199<=3199) | C | False | sensor.heatpump_compressor_temperature_(TR1) | sensor.heatpump_hptr1 |
HP Module | heatpump | 252 | hptr3 | refrigerant temperature liquid side (condenser output) (TR3) | int16 (>=-3199<=3199) | C | False | sensor.heatpump_refrigerant_temperature_liquid_side_(condenser_output)_(TR3) | sensor.heatpump_hptr3 |
HP Module | heatpump | 252 | hptr4 | evaporator inlet temperature (TR4) | int16 (>=-3199<=3199) | C | False | sensor.heatpump_evaporator_inlet_temperature_(TR4) | sensor.heatpump_hptr4 |
HP Module | heatpump | 252 | hptr5 | compressor inlet temperature (TR5) | int16 (>=-3199<=3199) | C | False | sensor.heatpump_compressor_inlet_temperature_(TR5) | sensor.heatpump_hptr5 |
HP Module | heatpump | 252 | hptr6 | compressor outlet temperature (TR6) | int16 (>=-3199<=3199) | C | False | sensor.heatpump_compressor_outlet_temperature_(TR6) | sensor.heatpump_hptr6 |
HP Module | heatpump | 252 | hptl2 | air inlet temperature (TL2) | int16 (>=-3199<=3199) | C | False | sensor.heatpump_air_inlet_temperature_(TL2) | sensor.heatpump_hptl2 |
HP Module | heatpump | 252 | hppl1 | low pressure side temperature (PL1) | int16 (>=-3199<=3199) | C | False | sensor.heatpump_low_pressure_side_temperature_(PL1) | sensor.heatpump_hppl1 |
HP Module | heatpump | 252 | hpph1 | high pressure side temperature (PH1) | int16 (>=-3199<=3199) | C | False | sensor.heatpump_high_pressure_side_temperature_(PH1) | sensor.heatpump_hpph1 |
HP Module | heatpump | 252 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.heatpump_heating_pump_modulation | sensor.heatpump_heatingpumpmod |
HP Module | heatpump | 252 | hpcompspd | compressor speed | uint8 (>=0<=100) | % | False | sensor.heatpump_compressor_speed | sensor.heatpump_hpcompspd |
HP Module | heatpump | 252 | hybridstrategy | hybrid control strategy | enum [cost optimized|co2 optimized|outside temperature alt.|outside temperature parallel|heatpump prefered|boiler only] | True | select.heatpump_hybrid_control_strategy | select.heatpump_hybridstrategy | |
HP Module | heatpump | 252 | lownoisemode | low noise mode | enum [off|reduced output|switch off hp|perm. reduced] | True | select.heatpump_low_noise_mode | select.heatpump_lownoisemode | |
HP Module | heatpump | 252 | lownoisestart | low noise starttime | uint8 (>=0<=23) | True | number.heatpump_low_noise_starttime | number.heatpump_lownoisestart | |
HP Module | heatpump | 252 | lownoisestop | low noise stoptime | uint8 (>=0<=23) | True | number.heatpump_low_noise_stoptime | number.heatpump_lownoisestop | |
HP Module | heatpump | 252 | hybriddhw | hybrid DHW | enum [eco|high comfort] | True | select.heatpump_hybrid_DHW | select.heatpump_hybriddhw | |
HP Module | heatpump | 252 | energypricegas | energy price gas | uint8 (>=0<=254) | True | number.heatpump_energy_price_gas | number.heatpump_energypricegas | |
HP Module | heatpump | 252 | energypriceel | energy price electric | uint8 (>=0<=254) | True | number.heatpump_energy_price_electric | number.heatpump_energypriceel | |
HP Module | heatpump | 252 | energyfeedpv | feed in PV | uint8 (>=0<=254) | True | number.heatpump_feed_in_PV | number.heatpump_energyfeedpv | |
HP Module | heatpump | 252 | switchovertemp | outside switchover temperature | int8 (>=-126<=126) | True | number.heatpump_outside_switchover_temperature | number.heatpump_switchovertemp | |
HP Module | heatpump | 252 | airpurgemode | air purge mode | boolean | True | switch.heatpump_air_purge_mode | switch.heatpump_airpurgemode | |
HP Module | heatpump | 252 | heatpumpoutput | heatpump output | uint8 (>=0<=100) | % | True | number.heatpump_heatpump_output | number.heatpump_heatpumpoutput |
HP Module | heatpump | 252 | coolingcircuit | cooling circuit | boolean | True | switch.heatpump_cooling_circuit | switch.heatpump_coolingcircuit | |
HP Module | heatpump | 252 | compstartmod | compressor start modulation | uint8 (>=0<=100) | % | True | number.heatpump_compressor_start_modulation | number.heatpump_compstartmod |
HP Module | heatpump | 252 | heatdrainpan | heat drain pan | boolean | True | switch.heatpump_heat_drain_pan | switch.heatpump_heatdrainpan | |
HP Module | heatpump | 252 | heatcable | heating cable | boolean | True | switch.heatpump_heating_cable | switch.heatpump_heatcable | |
HP Module | heatpump | 252 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.heatpump_total_energy | sensor.heatpump_nrgtotal |
HP Module | heatpump | 252 | nrgdhw | energy | uint24 (>=0<=167772) | kWh | False | sensor.heatpump_dhw_energy | sensor.heatpump_dhw_nrgdhw |
HP Module | heatpump | 252 | nrgheat | energy heating | uint24 (>=0<=167772) | kWh | False | sensor.heatpump_energy_heating | sensor.heatpump_nrgheat |
HP Module | heatpump | 252 | metertotal | meter total | uint24 (>=0<=167772) | kWh | False | sensor.heatpump_meter_total | sensor.heatpump_metertotal |
HP Module | heatpump | 252 | metercomp | meter compressor | uint24 (>=0<=167772) | kWh | False | sensor.heatpump_meter_compressor | sensor.heatpump_metercomp |
HP Module | heatpump | 252 | metereheat | meter e-heater | uint24 (>=0<=167772) | kWh | False | sensor.heatpump_meter_e-heater | sensor.heatpump_metereheat |
HP Module | heatpump | 252 | meterheat | meter heating | uint24 (>=0<=167772) | kWh | False | sensor.heatpump_meter_heating | sensor.heatpump_meterheat |
HP Module | heatpump | 252 | meterdhw | meter | uint24 (>=0<=167772) | kWh | False | sensor.heatpump_dhw_meter | sensor.heatpump_dhw_meterdhw |
Hybrid Manager HM200 | heatpump | 248 | airhumidity | relative air humidity | uint8 (>=0<=100) | % | False | sensor.heatpump_relative_air_humidity | sensor.heatpump_airhumidity |
Hybrid Manager HM200 | heatpump | 248 | dewtemperature | dew point temperature | uint8 (>=0<=254) | C | False | sensor.heatpump_dew_point_temperature | sensor.heatpump_dewtemperature |
Hybrid Manager HM200 | heatpump | 248 | curflowtemp | current flow temperature | int16 (>=-3199<=3199) | C | False | sensor.heatpump_current_flow_temperature | sensor.heatpump_curflowtemp |
Hybrid Manager HM200 | heatpump | 248 | rettemp | return temperature | int16 (>=-3199<=3199) | C | False | sensor.heatpump_return_temperature | sensor.heatpump_rettemp |
Hybrid Manager HM200 | heatpump | 248 | sysrettemp | system return temperature | int16 (>=-3199<=3199) | C | False | sensor.heatpump_system_return_temperature | sensor.heatpump_sysrettemp |
Hybrid Manager HM200 | heatpump | 248 | hpta4 | drain pan temp (TA4) | int16 (>=-3199<=3199) | C | False | sensor.heatpump_drain_pan_temp_(TA4) | sensor.heatpump_hpta4 |
Hybrid Manager HM200 | heatpump | 248 | hptr1 | compressor temperature (TR1) | int16 (>=-3199<=3199) | C | False | sensor.heatpump_compressor_temperature_(TR1) | sensor.heatpump_hptr1 |
Hybrid Manager HM200 | heatpump | 248 | hptr3 | refrigerant temperature liquid side (condenser output) (TR3) | int16 (>=-3199<=3199) | C | False | sensor.heatpump_refrigerant_temperature_liquid_side_(condenser_output)_(TR3) | sensor.heatpump_hptr3 |
Hybrid Manager HM200 | heatpump | 248 | hptr4 | evaporator inlet temperature (TR4) | int16 (>=-3199<=3199) | C | False | sensor.heatpump_evaporator_inlet_temperature_(TR4) | sensor.heatpump_hptr4 |
Hybrid Manager HM200 | heatpump | 248 | hptr5 | compressor inlet temperature (TR5) | int16 (>=-3199<=3199) | C | False | sensor.heatpump_compressor_inlet_temperature_(TR5) | sensor.heatpump_hptr5 |
Hybrid Manager HM200 | heatpump | 248 | hptr6 | compressor outlet temperature (TR6) | int16 (>=-3199<=3199) | C | False | sensor.heatpump_compressor_outlet_temperature_(TR6) | sensor.heatpump_hptr6 |
Hybrid Manager HM200 | heatpump | 248 | hptl2 | air inlet temperature (TL2) | int16 (>=-3199<=3199) | C | False | sensor.heatpump_air_inlet_temperature_(TL2) | sensor.heatpump_hptl2 |
Hybrid Manager HM200 | heatpump | 248 | hppl1 | low pressure side temperature (PL1) | int16 (>=-3199<=3199) | C | False | sensor.heatpump_low_pressure_side_temperature_(PL1) | sensor.heatpump_hppl1 |
Hybrid Manager HM200 | heatpump | 248 | hpph1 | high pressure side temperature (PH1) | int16 (>=-3199<=3199) | C | False | sensor.heatpump_high_pressure_side_temperature_(PH1) | sensor.heatpump_hpph1 |
Hybrid Manager HM200 | heatpump | 248 | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | False | sensor.heatpump_heating_pump_modulation | sensor.heatpump_heatingpumpmod |
Hybrid Manager HM200 | heatpump | 248 | hpcompspd | compressor speed | uint8 (>=0<=100) | % | False | sensor.heatpump_compressor_speed | sensor.heatpump_hpcompspd |
Hybrid Manager HM200 | heatpump | 248 | hybridstrategy | hybrid control strategy | enum [cost optimized|co2 optimized|outside temperature alt.|outside temperature parallel|heatpump prefered|boiler only] | True | select.heatpump_hybrid_control_strategy | select.heatpump_hybridstrategy | |
Hybrid Manager HM200 | heatpump | 248 | lownoisemode | low noise mode | enum [off|reduced output|switch off hp|perm. reduced] | True | select.heatpump_low_noise_mode | select.heatpump_lownoisemode | |
Hybrid Manager HM200 | heatpump | 248 | lownoisestart | low noise starttime | uint8 (>=0<=23) | True | number.heatpump_low_noise_starttime | number.heatpump_lownoisestart | |
Hybrid Manager HM200 | heatpump | 248 | lownoisestop | low noise stoptime | uint8 (>=0<=23) | True | number.heatpump_low_noise_stoptime | number.heatpump_lownoisestop | |
Hybrid Manager HM200 | heatpump | 248 | hybriddhw | hybrid DHW | enum [eco|high comfort] | True | select.heatpump_hybrid_DHW | select.heatpump_hybriddhw | |
Hybrid Manager HM200 | heatpump | 248 | energypricegas | energy price gas | uint8 (>=0<=254) | True | number.heatpump_energy_price_gas | number.heatpump_energypricegas | |
Hybrid Manager HM200 | heatpump | 248 | energypriceel | energy price electric | uint8 (>=0<=254) | True | number.heatpump_energy_price_electric | number.heatpump_energypriceel | |
Hybrid Manager HM200 | heatpump | 248 | energyfeedpv | feed in PV | uint8 (>=0<=254) | True | number.heatpump_feed_in_PV | number.heatpump_energyfeedpv | |
Hybrid Manager HM200 | heatpump | 248 | switchovertemp | outside switchover temperature | int8 (>=-126<=126) | True | number.heatpump_outside_switchover_temperature | number.heatpump_switchovertemp | |
Hybrid Manager HM200 | heatpump | 248 | airpurgemode | air purge mode | boolean | True | switch.heatpump_air_purge_mode | switch.heatpump_airpurgemode | |
Hybrid Manager HM200 | heatpump | 248 | heatpumpoutput | heatpump output | uint8 (>=0<=100) | % | True | number.heatpump_heatpump_output | number.heatpump_heatpumpoutput |
Hybrid Manager HM200 | heatpump | 248 | coolingcircuit | cooling circuit | boolean | True | switch.heatpump_cooling_circuit | switch.heatpump_coolingcircuit | |
Hybrid Manager HM200 | heatpump | 248 | compstartmod | compressor start modulation | uint8 (>=0<=100) | % | True | number.heatpump_compressor_start_modulation | number.heatpump_compstartmod |
Hybrid Manager HM200 | heatpump | 248 | heatdrainpan | heat drain pan | boolean | True | switch.heatpump_heat_drain_pan | switch.heatpump_heatdrainpan | |
Hybrid Manager HM200 | heatpump | 248 | heatcable | heating cable | boolean | True | switch.heatpump_heating_cable | switch.heatpump_heatcable | |
Hybrid Manager HM200 | heatpump | 248 | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | False | sensor.heatpump_total_energy | sensor.heatpump_nrgtotal |
Hybrid Manager HM200 | heatpump | 248 | nrgdhw | energy | uint24 (>=0<=167772) | kWh | False | sensor.heatpump_dhw_energy | sensor.heatpump_dhw_nrgdhw |
Hybrid Manager HM200 | heatpump | 248 | nrgheat | energy heating | uint24 (>=0<=167772) | kWh | False | sensor.heatpump_energy_heating | sensor.heatpump_nrgheat |
Hybrid Manager HM200 | heatpump | 248 | metertotal | meter total | uint24 (>=0<=167772) | kWh | False | sensor.heatpump_meter_total | sensor.heatpump_metertotal |
Hybrid Manager HM200 | heatpump | 248 | metercomp | meter compressor | uint24 (>=0<=167772) | kWh | False | sensor.heatpump_meter_compressor | sensor.heatpump_metercomp |
Hybrid Manager HM200 | heatpump | 248 | metereheat | meter e-heater | uint24 (>=0<=167772) | kWh | False | sensor.heatpump_meter_e-heater | sensor.heatpump_metereheat |
Hybrid Manager HM200 | heatpump | 248 | meterheat | meter heating | uint24 (>=0<=167772) | kWh | False | sensor.heatpump_meter_heating | sensor.heatpump_meterheat |
Hybrid Manager HM200 | heatpump | 248 | meterdhw | meter | uint24 (>=0<=167772) | kWh | False | sensor.heatpump_dhw_meter | sensor.heatpump_dhw_meterdhw |
WM10 | switch | 71 | activated | activated | boolean | False | binary_sensor.switch_activated | binary_sensor.switch_activated | |
WM10 | switch | 71 | flowtemphc | flow temperature (TC1) | uint16 (>=0<=3199) | C | False | sensor.switch_flow_temperature_(TC1) | sensor.switch_flowtemphc |
WM10 | switch | 71 | status | status | int8 (>=-126<=126) | False | sensor.switch_status | sensor.switch_status | |
Rego 3000 | controller | 240 | datetime | date/time | string | False | sensor.controller_date/time | sensor.controller_datetime | |
EM10 | alert | 74 | setflowtemp | set flow temperature | uint8 (>=0<=254) | C | False | sensor.alert_set_flow_temperature | sensor.alert_setflowtemp |
EM10 | alert | 74 | setburnpow | burner set power | uint8 (>=0<=100) | % | False | sensor.alert_burner_set_power | sensor.alert_setburnpow |
EM10/EM100 | extension | 243 | flowtempvf | flow temperature in header (T0/Vf) | int16 (>=-3199<=3199) | C | False | sensor.extension_flow_temperature_in_header_(T0/Vf) | sensor.extension_flowtempvf |
EM10/EM100 | extension | 243 | input | input | uint8 (>=0<=25) | V | False | sensor.extension_input | sensor.extension_input |
EM10/EM100 | extension | 243 | outpow | output IO1 | uint8 (>=0<=100) | % | False | sensor.extension_output_IO1 | sensor.extension_outpow |
EM10/EM100 | extension | 243 | setpower | request power | uint8 (>=0<=100) | % | False | sensor.extension_request_power | sensor.extension_setpower |
EM10/EM100 | extension | 243 | setpoint | set temp. | uint8 (>=0<=254) | C | False | sensor.extension_set_temp. | sensor.extension_setpoint |
EM10/EM100 | extension | 243 | minv | min volt. | uint8 (>=0<=25) | V | True | number.extension_min_volt. | number.extension_minv |
EM10/EM100 | extension | 243 | maxv | max volt. | uint8 (>=0<=25) | V | True | number.extension_max_volt. | number.extension_maxv |
EM10/EM100 | extension | 243 | mint | min temp. | uint8 (>=0<=254) | C | True | number.extension_min_temp. | number.extension_mint |
EM10/EM100 | extension | 243 | maxt | max temp. | uint8 (>=0<=254) | C | True | number.extension_max_temp. | number.extension_maxt |
EM10/EM100 | extension | 243 | mode | mode | uint8 (>=0<=254) | False | sensor.extension_mode | sensor.extension_mode | |
T1RF | extension | 220 | flowtempvf | flow temperature in header (T0/Vf) | int16 (>=-3199<=3199) | C | False | sensor.extension_flow_temperature_in_header_(T0/Vf) | sensor.extension_flowtempvf |
T1RF | extension | 220 | input | input | uint8 (>=0<=25) | V | False | sensor.extension_input | sensor.extension_input |
T1RF | extension | 220 | outpow | output IO1 | uint8 (>=0<=100) | % | False | sensor.extension_output_IO1 | sensor.extension_outpow |
T1RF | extension | 220 | setpower | request power | uint8 (>=0<=100) | % | False | sensor.extension_request_power | sensor.extension_setpower |
T1RF | extension | 220 | setpoint | set temp. | uint8 (>=0<=254) | C | False | sensor.extension_set_temp. | sensor.extension_setpoint |
T1RF | extension | 220 | minv | min volt. | uint8 (>=0<=25) | V | True | number.extension_min_volt. | number.extension_minv |
T1RF | extension | 220 | maxv | max volt. | uint8 (>=0<=25) | V | True | number.extension_max_volt. | number.extension_maxv |
T1RF | extension | 220 | mint | min temp. | uint8 (>=0<=254) | C | True | number.extension_min_temp. | number.extension_mint |
T1RF | extension | 220 | maxt | max temp. | uint8 (>=0<=254) | C | True | number.extension_max_temp. | number.extension_maxt |
T1RF | extension | 220 | mode | mode | uint8 (>=0<=254) | False | sensor.extension_mode | sensor.extension_mode | |
Logavent HRV176 | ventilation | 231 | outfresh | outdoor fresh air | int16 (>=-3199<=3199) | C | False | sensor.ventilation_outdoor_fresh_air | sensor.ventilation_outfresh |
Logavent HRV176 | ventilation | 231 | infresh | indoor fresh air | int16 (>=-3199<=3199) | C | False | sensor.ventilation_indoor_fresh_air | sensor.ventilation_infresh |
Logavent HRV176 | ventilation | 231 | outexhaust | outdoor exhaust air | int16 (>=-3199<=3199) | C | False | sensor.ventilation_outdoor_exhaust_air | sensor.ventilation_outexhaust |
Logavent HRV176 | ventilation | 231 | inexhaust | indoor exhaust air | int16 (>=-3199<=3199) | C | False | sensor.ventilation_indoor_exhaust_air | sensor.ventilation_inexhaust |
Logavent HRV176 | ventilation | 231 | ventinspeed | in blower speed | uint8 (>=0<=100) | % | False | sensor.ventilation_in_blower_speed | sensor.ventilation_ventinspeed |
Logavent HRV176 | ventilation | 231 | ventoutspeed | out blower speed | uint8 (>=0<=100) | % | False | sensor.ventilation_out_blower_speed | sensor.ventilation_ventoutspeed |
Logavent HRV176 | ventilation | 231 | ventmode | ventilation mode | enum [auto|off|L1|L2|L3|L4|demand|sleep|intense|bypass|party|fireplace] | True | select.ventilation_ventilation_mode | select.ventilation_ventmode | |
Logavent HRV176 | ventilation | 231 | airquality | air quality (voc) | uint16 (>=0<=31999) | False | sensor.ventilation_air_quality_(voc) | sensor.ventilation_airquality | |
Logavent HRV176 | ventilation | 231 | airhumidity | relative air humidity | uint8 (>=0<=100) | % | False | sensor.ventilation_relative_air_humidity | sensor.ventilation_airhumidity |
MP100 | pool | 204 | pooltemp | pool temperature | int16 (>=-3199<=3199) | C | False | sensor.pool_pool_temperature | sensor.pool_pooltemp |
MP100 | pool | 204 | poolshuntstatus | pool shunt status opening/closing | enum [stopped|opening|closing|open|close] | False | sensor.pool_pool_shunt_status_opening/closing | sensor.pool_poolshuntstatus | |
MP100 | pool | 204 | poolshunt | pool shunt open/close (0% = pool / 100% = heat) | uint8 (>=0<=100) | % | False | sensor.pool_pool_shunt_open/close_(0%=_pool/100%=_heat) | sensor.pool_poolshunt |