All Devices and Entities
please read
Make sure you have read and understood the Disclaimer before sending ambiguous messages to your EMS bus as you could cause serious damage to your equipment.
Most Bosch branded boilers that support the Logamatic EMS bus protocols work with this design. This includes Nefit, Buderus, Worcester, Junkers and Sieger (all copyrighted).
EMS devices are being constantly added to the database on each new release.
The following device types are supported:
- boiler
- thermostat
- heatpump
- heatsource
- solar
- connect
- mixer
- controller
- switch
- gateway
- alert
- pump
All devices and entities~
device name | device type | product id | shortname | fullname | type [options...] | (min/max) | uom | writeable | discovery entityid v3.4 | discovery entityid |
---|---|---|---|---|---|---|---|---|---|
BK13/BK15/Smartline/GB1x2 | boiler | 64 | reset | Reset | cmd [-|maintenance|error] | True | sensor.boiler_Reset | sensor.boiler_reset | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | rettemp | return temperature | ushort (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | syspress | system pressure | uint (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | burngas | gas | boolean | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | burngas2 | gas stage 2 | boolean | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | flamecurr | flame current | ushort (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | fanwork | fan | boolean | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | ignwork | ignition | boolean | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | oilpreheat | oil preheating | boolean | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | heatingtemp | heating temperature | uint (>=0<=254) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | pumpdelay | pump delay | uint (>=0<=254) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | burnminperiod | burner min period | uint (>=0<=254) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | burnminpower | burner min power | uint (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | burnmaxpower | burner max power | uint (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | setflowtemp | set flow temperature | uint (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | setburnpow | burner set power | uint (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | selburnpow | burner selected max power | uint (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | curburnpow | burner current power | uint (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | burnstarts | burner starts | ulong (>=0<=65533) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | heatstarts | burner starts heating | ulong (>=0<=65533) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | servicecodenumber | service code number | ushort (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | emergencytemp | emergency temperature | uint (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwtapactivated | turn on/off | boolean | True | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwsettemp | set temperature | uint (>=0<=254) | C | False | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwseltemp | selected temperature | uint (>=0<=254) | C | True | number.boiler_selected_temperature | number.boiler_wwseltemp |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | True | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | False | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | True | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | False | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwtype | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_type | sensor.boiler_wwtype | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwcomfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_comfort | select.boiler_wwcomfort | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwcomfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | True | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwchargeoptimization | charge optimization | boolean | True | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwmaxpower | max power | uint (>=0<=254) | % | True | number.boiler_max_power | number.boiler_wwmaxpower |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwmaxtemp | maximum temperature | uint (>=0<=70) | C | True | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwcircpump | circulation pump available | boolean | True | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwchargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwdisinfectiontemp | disinfection temperature | uint (>=0<=254) | C | True | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwcircmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwcirc | circulation active | boolean | True | switch.boiler_circulation_active | switch.boiler_wwcirc | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | False | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwactivated | activated | boolean | True | switch.boiler_activated | switch.boiler_wwactivated | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwonetime | one time charging | boolean | True | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwdisinfecting | disinfecting | boolean | True | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwcharging | charging | boolean | False | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwrecharging | recharging | boolean | False | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwtempok | temperature ok | boolean | False | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwactive | active | boolean | False | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | ww3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwsetpumppower | set pump power | uint (>=0<=100) | % | False | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | False | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | False | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwstarts | starts | ulong (>=0<=65533) | False | sensor.boiler_starts | sensor.boiler_wwstarts | |
BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwworkm | active time | time (>=0<=65533) | minutes | False | sensor.boiler_active_time | sensor.boiler_wwworkm |
GB125/GB135/MC10 | boiler | 72 | reset | Reset | cmd [-|maintenance|error] | True | sensor.boiler_Reset | sensor.boiler_reset | |
GB125/GB135/MC10 | boiler | 72 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
GB125/GB135/MC10 | boiler | 72 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
GB125/GB135/MC10 | boiler | 72 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
GB125/GB135/MC10 | boiler | 72 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
GB125/GB135/MC10 | boiler | 72 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
GB125/GB135/MC10 | boiler | 72 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
GB125/GB135/MC10 | boiler | 72 | rettemp | return temperature | ushort (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
GB125/GB135/MC10 | boiler | 72 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
GB125/GB135/MC10 | boiler | 72 | syspress | system pressure | uint (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
GB125/GB135/MC10 | boiler | 72 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
GB125/GB135/MC10 | boiler | 72 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
GB125/GB135/MC10 | boiler | 72 | burngas | gas | boolean | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
GB125/GB135/MC10 | boiler | 72 | burngas2 | gas stage 2 | boolean | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
GB125/GB135/MC10 | boiler | 72 | flamecurr | flame current | ushort (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr |
GB125/GB135/MC10 | boiler | 72 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
GB125/GB135/MC10 | boiler | 72 | fanwork | fan | boolean | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
GB125/GB135/MC10 | boiler | 72 | ignwork | ignition | boolean | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
GB125/GB135/MC10 | boiler | 72 | oilpreheat | oil preheating | boolean | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
GB125/GB135/MC10 | boiler | 72 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
GB125/GB135/MC10 | boiler | 72 | heatingtemp | heating temperature | uint (>=0<=254) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
GB125/GB135/MC10 | boiler | 72 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
GB125/GB135/MC10 | boiler | 72 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
GB125/GB135/MC10 | boiler | 72 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
GB125/GB135/MC10 | boiler | 72 | pumpdelay | pump delay | uint (>=0<=254) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
GB125/GB135/MC10 | boiler | 72 | burnminperiod | burner min period | uint (>=0<=254) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod |
GB125/GB135/MC10 | boiler | 72 | burnminpower | burner min power | uint (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower |
GB125/GB135/MC10 | boiler | 72 | burnmaxpower | burner max power | uint (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower |
GB125/GB135/MC10 | boiler | 72 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
GB125/GB135/MC10 | boiler | 72 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
GB125/GB135/MC10 | boiler | 72 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
GB125/GB135/MC10 | boiler | 72 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
GB125/GB135/MC10 | boiler | 72 | setflowtemp | set flow temperature | uint (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
GB125/GB135/MC10 | boiler | 72 | setburnpow | burner set power | uint (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
GB125/GB135/MC10 | boiler | 72 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
GB125/GB135/MC10 | boiler | 72 | selburnpow | burner selected max power | uint (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
GB125/GB135/MC10 | boiler | 72 | curburnpow | burner current power | uint (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
GB125/GB135/MC10 | boiler | 72 | burnstarts | burner starts | ulong (>=0<=65533) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
GB125/GB135/MC10 | boiler | 72 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
GB125/GB135/MC10 | boiler | 72 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
GB125/GB135/MC10 | boiler | 72 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
GB125/GB135/MC10 | boiler | 72 | heatstarts | burner starts heating | ulong (>=0<=65533) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
GB125/GB135/MC10 | boiler | 72 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
GB125/GB135/MC10 | boiler | 72 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
GB125/GB135/MC10 | boiler | 72 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
GB125/GB135/MC10 | boiler | 72 | servicecodenumber | service code number | ushort (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
GB125/GB135/MC10 | boiler | 72 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
GB125/GB135/MC10 | boiler | 72 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
GB125/GB135/MC10 | boiler | 72 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
GB125/GB135/MC10 | boiler | 72 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
GB125/GB135/MC10 | boiler | 72 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
GB125/GB135/MC10 | boiler | 72 | emergencytemp | emergency temperature | uint (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
GB125/GB135/MC10 | boiler | 72 | wwtapactivated | turn on/off | boolean | True | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
GB125/GB135/MC10 | boiler | 72 | wwsettemp | set temperature | uint (>=0<=254) | C | False | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
GB125/GB135/MC10 | boiler | 72 | wwseltemp | selected temperature | uint (>=0<=254) | C | True | number.boiler_selected_temperature | number.boiler_wwseltemp |
GB125/GB135/MC10 | boiler | 72 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | True | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
GB125/GB135/MC10 | boiler | 72 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | False | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
GB125/GB135/MC10 | boiler | 72 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | True | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
GB125/GB135/MC10 | boiler | 72 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | False | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
GB125/GB135/MC10 | boiler | 72 | wwtype | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_type | sensor.boiler_wwtype | |
GB125/GB135/MC10 | boiler | 72 | wwcomfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_comfort | select.boiler_wwcomfort | |
GB125/GB135/MC10 | boiler | 72 | wwcomfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
GB125/GB135/MC10 | boiler | 72 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | True | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
GB125/GB135/MC10 | boiler | 72 | wwchargeoptimization | charge optimization | boolean | True | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
GB125/GB135/MC10 | boiler | 72 | wwmaxpower | max power | uint (>=0<=254) | % | True | number.boiler_max_power | number.boiler_wwmaxpower |
GB125/GB135/MC10 | boiler | 72 | wwmaxtemp | maximum temperature | uint (>=0<=70) | C | True | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
GB125/GB135/MC10 | boiler | 72 | wwcircpump | circulation pump available | boolean | True | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
GB125/GB135/MC10 | boiler | 72 | wwchargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
GB125/GB135/MC10 | boiler | 72 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
GB125/GB135/MC10 | boiler | 72 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
GB125/GB135/MC10 | boiler | 72 | wwdisinfectiontemp | disinfection temperature | uint (>=0<=254) | C | True | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
GB125/GB135/MC10 | boiler | 72 | wwcircmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
GB125/GB135/MC10 | boiler | 72 | wwcirc | circulation active | boolean | True | switch.boiler_circulation_active | switch.boiler_wwcirc | |
GB125/GB135/MC10 | boiler | 72 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
GB125/GB135/MC10 | boiler | 72 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
GB125/GB135/MC10 | boiler | 72 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | False | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
GB125/GB135/MC10 | boiler | 72 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
GB125/GB135/MC10 | boiler | 72 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
GB125/GB135/MC10 | boiler | 72 | wwactivated | activated | boolean | True | switch.boiler_activated | switch.boiler_wwactivated | |
GB125/GB135/MC10 | boiler | 72 | wwonetime | one time charging | boolean | True | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
GB125/GB135/MC10 | boiler | 72 | wwdisinfecting | disinfecting | boolean | True | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
GB125/GB135/MC10 | boiler | 72 | wwcharging | charging | boolean | False | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
GB125/GB135/MC10 | boiler | 72 | wwrecharging | recharging | boolean | False | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
GB125/GB135/MC10 | boiler | 72 | wwtempok | temperature ok | boolean | False | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
GB125/GB135/MC10 | boiler | 72 | wwactive | active | boolean | False | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
GB125/GB135/MC10 | boiler | 72 | ww3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
GB125/GB135/MC10 | boiler | 72 | wwsetpumppower | set pump power | uint (>=0<=100) | % | False | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
GB125/GB135/MC10 | boiler | 72 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | False | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
GB125/GB135/MC10 | boiler | 72 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | False | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
GB125/GB135/MC10 | boiler | 72 | wwstarts | starts | ulong (>=0<=65533) | False | sensor.boiler_starts | sensor.boiler_wwstarts | |
GB125/GB135/MC10 | boiler | 72 | wwworkm | active time | time (>=0<=65533) | minutes | False | sensor.boiler_active_time | sensor.boiler_wwworkm |
Cascade CM10 | boiler | 81 | reset | Reset | cmd [-|maintenance|error] | True | sensor.boiler_Reset | sensor.boiler_reset | |
Cascade CM10 | boiler | 81 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
Cascade CM10 | boiler | 81 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
Cascade CM10 | boiler | 81 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
Cascade CM10 | boiler | 81 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
Cascade CM10 | boiler | 81 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
Cascade CM10 | boiler | 81 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
Cascade CM10 | boiler | 81 | rettemp | return temperature | ushort (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
Cascade CM10 | boiler | 81 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
Cascade CM10 | boiler | 81 | syspress | system pressure | uint (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
Cascade CM10 | boiler | 81 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
Cascade CM10 | boiler | 81 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
Cascade CM10 | boiler | 81 | burngas | gas | boolean | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
Cascade CM10 | boiler | 81 | burngas2 | gas stage 2 | boolean | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
Cascade CM10 | boiler | 81 | flamecurr | flame current | ushort (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr |
Cascade CM10 | boiler | 81 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
Cascade CM10 | boiler | 81 | fanwork | fan | boolean | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
Cascade CM10 | boiler | 81 | ignwork | ignition | boolean | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
Cascade CM10 | boiler | 81 | oilpreheat | oil preheating | boolean | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
Cascade CM10 | boiler | 81 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
Cascade CM10 | boiler | 81 | heatingtemp | heating temperature | uint (>=0<=254) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
Cascade CM10 | boiler | 81 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
Cascade CM10 | boiler | 81 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
Cascade CM10 | boiler | 81 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
Cascade CM10 | boiler | 81 | pumpdelay | pump delay | uint (>=0<=254) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
Cascade CM10 | boiler | 81 | burnminperiod | burner min period | uint (>=0<=254) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod |
Cascade CM10 | boiler | 81 | burnminpower | burner min power | uint (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower |
Cascade CM10 | boiler | 81 | burnmaxpower | burner max power | uint (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower |
Cascade CM10 | boiler | 81 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
Cascade CM10 | boiler | 81 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
Cascade CM10 | boiler | 81 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
Cascade CM10 | boiler | 81 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
Cascade CM10 | boiler | 81 | setflowtemp | set flow temperature | uint (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
Cascade CM10 | boiler | 81 | setburnpow | burner set power | uint (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
Cascade CM10 | boiler | 81 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
Cascade CM10 | boiler | 81 | selburnpow | burner selected max power | uint (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
Cascade CM10 | boiler | 81 | curburnpow | burner current power | uint (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
Cascade CM10 | boiler | 81 | burnstarts | burner starts | ulong (>=0<=65533) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
Cascade CM10 | boiler | 81 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
Cascade CM10 | boiler | 81 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
Cascade CM10 | boiler | 81 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
Cascade CM10 | boiler | 81 | heatstarts | burner starts heating | ulong (>=0<=65533) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
Cascade CM10 | boiler | 81 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
Cascade CM10 | boiler | 81 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
Cascade CM10 | boiler | 81 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
Cascade CM10 | boiler | 81 | servicecodenumber | service code number | ushort (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
Cascade CM10 | boiler | 81 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
Cascade CM10 | boiler | 81 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
Cascade CM10 | boiler | 81 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
Cascade CM10 | boiler | 81 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
Cascade CM10 | boiler | 81 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
Cascade CM10 | boiler | 81 | emergencytemp | emergency temperature | uint (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
Cascade CM10 | boiler | 81 | wwtapactivated | turn on/off | boolean | True | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
Cascade CM10 | boiler | 81 | wwsettemp | set temperature | uint (>=0<=254) | C | False | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
Cascade CM10 | boiler | 81 | wwseltemp | selected temperature | uint (>=0<=254) | C | True | number.boiler_selected_temperature | number.boiler_wwseltemp |
Cascade CM10 | boiler | 81 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | True | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
Cascade CM10 | boiler | 81 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | False | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
Cascade CM10 | boiler | 81 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | True | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
Cascade CM10 | boiler | 81 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | False | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
Cascade CM10 | boiler | 81 | wwtype | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_type | sensor.boiler_wwtype | |
Cascade CM10 | boiler | 81 | wwcomfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_comfort | select.boiler_wwcomfort | |
Cascade CM10 | boiler | 81 | wwcomfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
Cascade CM10 | boiler | 81 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | True | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
Cascade CM10 | boiler | 81 | wwchargeoptimization | charge optimization | boolean | True | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
Cascade CM10 | boiler | 81 | wwmaxpower | max power | uint (>=0<=254) | % | True | number.boiler_max_power | number.boiler_wwmaxpower |
Cascade CM10 | boiler | 81 | wwmaxtemp | maximum temperature | uint (>=0<=70) | C | True | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
Cascade CM10 | boiler | 81 | wwcircpump | circulation pump available | boolean | True | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
Cascade CM10 | boiler | 81 | wwchargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
Cascade CM10 | boiler | 81 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
Cascade CM10 | boiler | 81 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
Cascade CM10 | boiler | 81 | wwdisinfectiontemp | disinfection temperature | uint (>=0<=254) | C | True | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
Cascade CM10 | boiler | 81 | wwcircmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
Cascade CM10 | boiler | 81 | wwcirc | circulation active | boolean | True | switch.boiler_circulation_active | switch.boiler_wwcirc | |
Cascade CM10 | boiler | 81 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
Cascade CM10 | boiler | 81 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
Cascade CM10 | boiler | 81 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | False | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
Cascade CM10 | boiler | 81 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
Cascade CM10 | boiler | 81 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
Cascade CM10 | boiler | 81 | wwactivated | activated | boolean | True | switch.boiler_activated | switch.boiler_wwactivated | |
Cascade CM10 | boiler | 81 | wwonetime | one time charging | boolean | True | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
Cascade CM10 | boiler | 81 | wwdisinfecting | disinfecting | boolean | True | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
Cascade CM10 | boiler | 81 | wwcharging | charging | boolean | False | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
Cascade CM10 | boiler | 81 | wwrecharging | recharging | boolean | False | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
Cascade CM10 | boiler | 81 | wwtempok | temperature ok | boolean | False | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
Cascade CM10 | boiler | 81 | wwactive | active | boolean | False | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
Cascade CM10 | boiler | 81 | ww3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
Cascade CM10 | boiler | 81 | wwsetpumppower | set pump power | uint (>=0<=100) | % | False | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
Cascade CM10 | boiler | 81 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | False | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
Cascade CM10 | boiler | 81 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | False | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
Cascade CM10 | boiler | 81 | wwstarts | starts | ulong (>=0<=65533) | False | sensor.boiler_starts | sensor.boiler_wwstarts | |
Cascade CM10 | boiler | 81 | wwworkm | active time | time (>=0<=65533) | minutes | False | sensor.boiler_active_time | sensor.boiler_wwworkm |
Logamax Plus GB022 | boiler | 84 | reset | Reset | cmd [-|maintenance|error] | True | sensor.boiler_Reset | sensor.boiler_reset | |
Logamax Plus GB022 | boiler | 84 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
Logamax Plus GB022 | boiler | 84 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
Logamax Plus GB022 | boiler | 84 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
Logamax Plus GB022 | boiler | 84 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
Logamax Plus GB022 | boiler | 84 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
Logamax Plus GB022 | boiler | 84 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
Logamax Plus GB022 | boiler | 84 | rettemp | return temperature | ushort (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
Logamax Plus GB022 | boiler | 84 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
Logamax Plus GB022 | boiler | 84 | syspress | system pressure | uint (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
Logamax Plus GB022 | boiler | 84 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
Logamax Plus GB022 | boiler | 84 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
Logamax Plus GB022 | boiler | 84 | burngas | gas | boolean | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
Logamax Plus GB022 | boiler | 84 | burngas2 | gas stage 2 | boolean | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
Logamax Plus GB022 | boiler | 84 | flamecurr | flame current | ushort (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr |
Logamax Plus GB022 | boiler | 84 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
Logamax Plus GB022 | boiler | 84 | fanwork | fan | boolean | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
Logamax Plus GB022 | boiler | 84 | ignwork | ignition | boolean | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
Logamax Plus GB022 | boiler | 84 | oilpreheat | oil preheating | boolean | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
Logamax Plus GB022 | boiler | 84 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
Logamax Plus GB022 | boiler | 84 | heatingtemp | heating temperature | uint (>=0<=254) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
Logamax Plus GB022 | boiler | 84 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
Logamax Plus GB022 | boiler | 84 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
Logamax Plus GB022 | boiler | 84 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
Logamax Plus GB022 | boiler | 84 | pumpdelay | pump delay | uint (>=0<=254) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
Logamax Plus GB022 | boiler | 84 | burnminperiod | burner min period | uint (>=0<=254) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod |
Logamax Plus GB022 | boiler | 84 | burnminpower | burner min power | uint (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower |
Logamax Plus GB022 | boiler | 84 | burnmaxpower | burner max power | uint (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower |
Logamax Plus GB022 | boiler | 84 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
Logamax Plus GB022 | boiler | 84 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
Logamax Plus GB022 | boiler | 84 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
Logamax Plus GB022 | boiler | 84 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
Logamax Plus GB022 | boiler | 84 | setflowtemp | set flow temperature | uint (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
Logamax Plus GB022 | boiler | 84 | setburnpow | burner set power | uint (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
Logamax Plus GB022 | boiler | 84 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
Logamax Plus GB022 | boiler | 84 | selburnpow | burner selected max power | uint (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
Logamax Plus GB022 | boiler | 84 | curburnpow | burner current power | uint (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
Logamax Plus GB022 | boiler | 84 | burnstarts | burner starts | ulong (>=0<=65533) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
Logamax Plus GB022 | boiler | 84 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
Logamax Plus GB022 | boiler | 84 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
Logamax Plus GB022 | boiler | 84 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
Logamax Plus GB022 | boiler | 84 | heatstarts | burner starts heating | ulong (>=0<=65533) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
Logamax Plus GB022 | boiler | 84 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
Logamax Plus GB022 | boiler | 84 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
Logamax Plus GB022 | boiler | 84 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
Logamax Plus GB022 | boiler | 84 | servicecodenumber | service code number | ushort (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
Logamax Plus GB022 | boiler | 84 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
Logamax Plus GB022 | boiler | 84 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
Logamax Plus GB022 | boiler | 84 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
Logamax Plus GB022 | boiler | 84 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
Logamax Plus GB022 | boiler | 84 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
Logamax Plus GB022 | boiler | 84 | emergencytemp | emergency temperature | uint (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
Logamax Plus GB022 | boiler | 84 | wwtapactivated | turn on/off | boolean | True | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
Logamax Plus GB022 | boiler | 84 | wwsettemp | set temperature | uint (>=0<=254) | C | False | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
Logamax Plus GB022 | boiler | 84 | wwseltemp | selected temperature | uint (>=0<=254) | C | True | number.boiler_selected_temperature | number.boiler_wwseltemp |
Logamax Plus GB022 | boiler | 84 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | True | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
Logamax Plus GB022 | boiler | 84 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | False | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
Logamax Plus GB022 | boiler | 84 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | True | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
Logamax Plus GB022 | boiler | 84 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | False | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
Logamax Plus GB022 | boiler | 84 | wwtype | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_type | sensor.boiler_wwtype | |
Logamax Plus GB022 | boiler | 84 | wwcomfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_comfort | select.boiler_wwcomfort | |
Logamax Plus GB022 | boiler | 84 | wwcomfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
Logamax Plus GB022 | boiler | 84 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | True | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
Logamax Plus GB022 | boiler | 84 | wwchargeoptimization | charge optimization | boolean | True | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
Logamax Plus GB022 | boiler | 84 | wwmaxpower | max power | uint (>=0<=254) | % | True | number.boiler_max_power | number.boiler_wwmaxpower |
Logamax Plus GB022 | boiler | 84 | wwmaxtemp | maximum temperature | uint (>=0<=70) | C | True | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
Logamax Plus GB022 | boiler | 84 | wwcircpump | circulation pump available | boolean | True | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
Logamax Plus GB022 | boiler | 84 | wwchargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
Logamax Plus GB022 | boiler | 84 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
Logamax Plus GB022 | boiler | 84 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
Logamax Plus GB022 | boiler | 84 | wwdisinfectiontemp | disinfection temperature | uint (>=0<=254) | C | True | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
Logamax Plus GB022 | boiler | 84 | wwcircmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
Logamax Plus GB022 | boiler | 84 | wwcirc | circulation active | boolean | True | switch.boiler_circulation_active | switch.boiler_wwcirc | |
Logamax Plus GB022 | boiler | 84 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
Logamax Plus GB022 | boiler | 84 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
Logamax Plus GB022 | boiler | 84 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | False | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
Logamax Plus GB022 | boiler | 84 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
Logamax Plus GB022 | boiler | 84 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
Logamax Plus GB022 | boiler | 84 | wwactivated | activated | boolean | True | switch.boiler_activated | switch.boiler_wwactivated | |
Logamax Plus GB022 | boiler | 84 | wwonetime | one time charging | boolean | True | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
Logamax Plus GB022 | boiler | 84 | wwdisinfecting | disinfecting | boolean | True | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
Logamax Plus GB022 | boiler | 84 | wwcharging | charging | boolean | False | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
Logamax Plus GB022 | boiler | 84 | wwrecharging | recharging | boolean | False | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
Logamax Plus GB022 | boiler | 84 | wwtempok | temperature ok | boolean | False | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
Logamax Plus GB022 | boiler | 84 | wwactive | active | boolean | False | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
Logamax Plus GB022 | boiler | 84 | ww3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
Logamax Plus GB022 | boiler | 84 | wwsetpumppower | set pump power | uint (>=0<=100) | % | False | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
Logamax Plus GB022 | boiler | 84 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | False | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
Logamax Plus GB022 | boiler | 84 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | False | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
Logamax Plus GB022 | boiler | 84 | wwstarts | starts | ulong (>=0<=65533) | False | sensor.boiler_starts | sensor.boiler_wwstarts | |
Logamax Plus GB022 | boiler | 84 | wwworkm | active time | time (>=0<=65533) | minutes | False | sensor.boiler_active_time | sensor.boiler_wwworkm |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | reset | Reset | cmd [-|maintenance|error] | True | sensor.boiler_Reset | sensor.boiler_reset | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | rettemp | return temperature | ushort (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | syspress | system pressure | uint (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | burngas | gas | boolean | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | burngas2 | gas stage 2 | boolean | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | flamecurr | flame current | ushort (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | fanwork | fan | boolean | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | ignwork | ignition | boolean | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | oilpreheat | oil preheating | boolean | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | heatingtemp | heating temperature | uint (>=0<=254) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | pumpdelay | pump delay | uint (>=0<=254) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | burnminperiod | burner min period | uint (>=0<=254) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | burnminpower | burner min power | uint (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | burnmaxpower | burner max power | uint (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | setflowtemp | set flow temperature | uint (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | setburnpow | burner set power | uint (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | selburnpow | burner selected max power | uint (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | curburnpow | burner current power | uint (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | burnstarts | burner starts | ulong (>=0<=65533) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | heatstarts | burner starts heating | ulong (>=0<=65533) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | servicecodenumber | service code number | ushort (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | emergencytemp | emergency temperature | uint (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwtapactivated | turn on/off | boolean | True | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwsettemp | set temperature | uint (>=0<=254) | C | False | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwseltemp | selected temperature | uint (>=0<=254) | C | True | number.boiler_selected_temperature | number.boiler_wwseltemp |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | True | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | False | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | True | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | False | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwtype | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_type | sensor.boiler_wwtype | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwcomfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_comfort | select.boiler_wwcomfort | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwcomfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | True | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwchargeoptimization | charge optimization | boolean | True | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwmaxpower | max power | uint (>=0<=254) | % | True | number.boiler_max_power | number.boiler_wwmaxpower |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwmaxtemp | maximum temperature | uint (>=0<=70) | C | True | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwcircpump | circulation pump available | boolean | True | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwchargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwdisinfectiontemp | disinfection temperature | uint (>=0<=254) | C | True | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwcircmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwcirc | circulation active | boolean | True | switch.boiler_circulation_active | switch.boiler_wwcirc | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | False | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwactivated | activated | boolean | True | switch.boiler_activated | switch.boiler_wwactivated | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwonetime | one time charging | boolean | True | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwdisinfecting | disinfecting | boolean | True | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwcharging | charging | boolean | False | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwrecharging | recharging | boolean | False | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwtempok | temperature ok | boolean | False | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwactive | active | boolean | False | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | ww3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwsetpumppower | set pump power | uint (>=0<=100) | % | False | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | False | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | False | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwstarts | starts | ulong (>=0<=65533) | False | sensor.boiler_starts | sensor.boiler_wwstarts | |
Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwworkm | active time | time (>=0<=65533) | minutes | False | sensor.boiler_active_time | sensor.boiler_wwworkm |
Topline/GB162 | boiler | 115 | reset | Reset | cmd [-|maintenance|error] | True | sensor.boiler_Reset | sensor.boiler_reset | |
Topline/GB162 | boiler | 115 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
Topline/GB162 | boiler | 115 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
Topline/GB162 | boiler | 115 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
Topline/GB162 | boiler | 115 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
Topline/GB162 | boiler | 115 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
Topline/GB162 | boiler | 115 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
Topline/GB162 | boiler | 115 | rettemp | return temperature | ushort (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
Topline/GB162 | boiler | 115 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
Topline/GB162 | boiler | 115 | syspress | system pressure | uint (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
Topline/GB162 | boiler | 115 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
Topline/GB162 | boiler | 115 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
Topline/GB162 | boiler | 115 | burngas | gas | boolean | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
Topline/GB162 | boiler | 115 | burngas2 | gas stage 2 | boolean | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
Topline/GB162 | boiler | 115 | flamecurr | flame current | ushort (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr |
Topline/GB162 | boiler | 115 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
Topline/GB162 | boiler | 115 | fanwork | fan | boolean | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
Topline/GB162 | boiler | 115 | ignwork | ignition | boolean | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
Topline/GB162 | boiler | 115 | oilpreheat | oil preheating | boolean | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
Topline/GB162 | boiler | 115 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
Topline/GB162 | boiler | 115 | heatingtemp | heating temperature | uint (>=0<=254) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
Topline/GB162 | boiler | 115 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
Topline/GB162 | boiler | 115 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
Topline/GB162 | boiler | 115 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
Topline/GB162 | boiler | 115 | pumpdelay | pump delay | uint (>=0<=254) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
Topline/GB162 | boiler | 115 | burnminperiod | burner min period | uint (>=0<=254) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod |
Topline/GB162 | boiler | 115 | burnminpower | burner min power | uint (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower |
Topline/GB162 | boiler | 115 | burnmaxpower | burner max power | uint (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower |
Topline/GB162 | boiler | 115 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
Topline/GB162 | boiler | 115 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
Topline/GB162 | boiler | 115 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
Topline/GB162 | boiler | 115 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
Topline/GB162 | boiler | 115 | setflowtemp | set flow temperature | uint (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
Topline/GB162 | boiler | 115 | setburnpow | burner set power | uint (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
Topline/GB162 | boiler | 115 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
Topline/GB162 | boiler | 115 | selburnpow | burner selected max power | uint (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
Topline/GB162 | boiler | 115 | curburnpow | burner current power | uint (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
Topline/GB162 | boiler | 115 | burnstarts | burner starts | ulong (>=0<=65533) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
Topline/GB162 | boiler | 115 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
Topline/GB162 | boiler | 115 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
Topline/GB162 | boiler | 115 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
Topline/GB162 | boiler | 115 | heatstarts | burner starts heating | ulong (>=0<=65533) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
Topline/GB162 | boiler | 115 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
Topline/GB162 | boiler | 115 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
Topline/GB162 | boiler | 115 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
Topline/GB162 | boiler | 115 | servicecodenumber | service code number | ushort (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
Topline/GB162 | boiler | 115 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
Topline/GB162 | boiler | 115 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
Topline/GB162 | boiler | 115 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
Topline/GB162 | boiler | 115 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
Topline/GB162 | boiler | 115 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
Topline/GB162 | boiler | 115 | emergencytemp | emergency temperature | uint (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
Topline/GB162 | boiler | 115 | wwtapactivated | turn on/off | boolean | True | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
Topline/GB162 | boiler | 115 | wwsettemp | set temperature | uint (>=0<=254) | C | False | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
Topline/GB162 | boiler | 115 | wwseltemp | selected temperature | uint (>=0<=254) | C | True | number.boiler_selected_temperature | number.boiler_wwseltemp |
Topline/GB162 | boiler | 115 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | True | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
Topline/GB162 | boiler | 115 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | False | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
Topline/GB162 | boiler | 115 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | True | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
Topline/GB162 | boiler | 115 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | False | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
Topline/GB162 | boiler | 115 | wwtype | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_type | sensor.boiler_wwtype | |
Topline/GB162 | boiler | 115 | wwcomfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_comfort | select.boiler_wwcomfort | |
Topline/GB162 | boiler | 115 | wwcomfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
Topline/GB162 | boiler | 115 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | True | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
Topline/GB162 | boiler | 115 | wwchargeoptimization | charge optimization | boolean | True | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
Topline/GB162 | boiler | 115 | wwmaxpower | max power | uint (>=0<=254) | % | True | number.boiler_max_power | number.boiler_wwmaxpower |
Topline/GB162 | boiler | 115 | wwmaxtemp | maximum temperature | uint (>=0<=70) | C | True | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
Topline/GB162 | boiler | 115 | wwcircpump | circulation pump available | boolean | True | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
Topline/GB162 | boiler | 115 | wwchargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
Topline/GB162 | boiler | 115 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
Topline/GB162 | boiler | 115 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
Topline/GB162 | boiler | 115 | wwdisinfectiontemp | disinfection temperature | uint (>=0<=254) | C | True | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
Topline/GB162 | boiler | 115 | wwcircmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
Topline/GB162 | boiler | 115 | wwcirc | circulation active | boolean | True | switch.boiler_circulation_active | switch.boiler_wwcirc | |
Topline/GB162 | boiler | 115 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
Topline/GB162 | boiler | 115 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
Topline/GB162 | boiler | 115 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | False | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
Topline/GB162 | boiler | 115 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
Topline/GB162 | boiler | 115 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
Topline/GB162 | boiler | 115 | wwactivated | activated | boolean | True | switch.boiler_activated | switch.boiler_wwactivated | |
Topline/GB162 | boiler | 115 | wwonetime | one time charging | boolean | True | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
Topline/GB162 | boiler | 115 | wwdisinfecting | disinfecting | boolean | True | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
Topline/GB162 | boiler | 115 | wwcharging | charging | boolean | False | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
Topline/GB162 | boiler | 115 | wwrecharging | recharging | boolean | False | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
Topline/GB162 | boiler | 115 | wwtempok | temperature ok | boolean | False | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
Topline/GB162 | boiler | 115 | wwactive | active | boolean | False | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
Topline/GB162 | boiler | 115 | ww3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
Topline/GB162 | boiler | 115 | wwsetpumppower | set pump power | uint (>=0<=100) | % | False | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
Topline/GB162 | boiler | 115 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | False | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
Topline/GB162 | boiler | 115 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | False | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
Topline/GB162 | boiler | 115 | wwstarts | starts | ulong (>=0<=65533) | False | sensor.boiler_starts | sensor.boiler_wwstarts | |
Topline/GB162 | boiler | 115 | wwworkm | active time | time (>=0<=65533) | minutes | False | sensor.boiler_active_time | sensor.boiler_wwworkm |
Cascade MCM10 | boiler | 121 | reset | Reset | cmd [-|maintenance|error] | True | sensor.boiler_Reset | sensor.boiler_reset | |
Cascade MCM10 | boiler | 121 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
Cascade MCM10 | boiler | 121 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
Cascade MCM10 | boiler | 121 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
Cascade MCM10 | boiler | 121 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
Cascade MCM10 | boiler | 121 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
Cascade MCM10 | boiler | 121 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
Cascade MCM10 | boiler | 121 | rettemp | return temperature | ushort (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
Cascade MCM10 | boiler | 121 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
Cascade MCM10 | boiler | 121 | syspress | system pressure | uint (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
Cascade MCM10 | boiler | 121 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
Cascade MCM10 | boiler | 121 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
Cascade MCM10 | boiler | 121 | burngas | gas | boolean | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
Cascade MCM10 | boiler | 121 | burngas2 | gas stage 2 | boolean | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
Cascade MCM10 | boiler | 121 | flamecurr | flame current | ushort (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr |
Cascade MCM10 | boiler | 121 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
Cascade MCM10 | boiler | 121 | fanwork | fan | boolean | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
Cascade MCM10 | boiler | 121 | ignwork | ignition | boolean | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
Cascade MCM10 | boiler | 121 | oilpreheat | oil preheating | boolean | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
Cascade MCM10 | boiler | 121 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
Cascade MCM10 | boiler | 121 | heatingtemp | heating temperature | uint (>=0<=254) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
Cascade MCM10 | boiler | 121 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
Cascade MCM10 | boiler | 121 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
Cascade MCM10 | boiler | 121 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
Cascade MCM10 | boiler | 121 | pumpdelay | pump delay | uint (>=0<=254) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
Cascade MCM10 | boiler | 121 | burnminperiod | burner min period | uint (>=0<=254) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod |
Cascade MCM10 | boiler | 121 | burnminpower | burner min power | uint (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower |
Cascade MCM10 | boiler | 121 | burnmaxpower | burner max power | uint (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower |
Cascade MCM10 | boiler | 121 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
Cascade MCM10 | boiler | 121 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
Cascade MCM10 | boiler | 121 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
Cascade MCM10 | boiler | 121 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
Cascade MCM10 | boiler | 121 | setflowtemp | set flow temperature | uint (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
Cascade MCM10 | boiler | 121 | setburnpow | burner set power | uint (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
Cascade MCM10 | boiler | 121 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
Cascade MCM10 | boiler | 121 | selburnpow | burner selected max power | uint (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
Cascade MCM10 | boiler | 121 | curburnpow | burner current power | uint (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
Cascade MCM10 | boiler | 121 | burnstarts | burner starts | ulong (>=0<=65533) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
Cascade MCM10 | boiler | 121 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
Cascade MCM10 | boiler | 121 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
Cascade MCM10 | boiler | 121 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
Cascade MCM10 | boiler | 121 | heatstarts | burner starts heating | ulong (>=0<=65533) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
Cascade MCM10 | boiler | 121 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
Cascade MCM10 | boiler | 121 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
Cascade MCM10 | boiler | 121 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
Cascade MCM10 | boiler | 121 | servicecodenumber | service code number | ushort (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
Cascade MCM10 | boiler | 121 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
Cascade MCM10 | boiler | 121 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
Cascade MCM10 | boiler | 121 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
Cascade MCM10 | boiler | 121 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
Cascade MCM10 | boiler | 121 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
Cascade MCM10 | boiler | 121 | emergencytemp | emergency temperature | uint (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
Cascade MCM10 | boiler | 121 | wwtapactivated | turn on/off | boolean | True | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
Cascade MCM10 | boiler | 121 | wwsettemp | set temperature | uint (>=0<=254) | C | False | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
Cascade MCM10 | boiler | 121 | wwseltemp | selected temperature | uint (>=0<=254) | C | True | number.boiler_selected_temperature | number.boiler_wwseltemp |
Cascade MCM10 | boiler | 121 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | True | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
Cascade MCM10 | boiler | 121 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | False | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
Cascade MCM10 | boiler | 121 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | True | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
Cascade MCM10 | boiler | 121 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | False | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
Cascade MCM10 | boiler | 121 | wwtype | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_type | sensor.boiler_wwtype | |
Cascade MCM10 | boiler | 121 | wwcomfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_comfort | select.boiler_wwcomfort | |
Cascade MCM10 | boiler | 121 | wwcomfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
Cascade MCM10 | boiler | 121 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | True | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
Cascade MCM10 | boiler | 121 | wwchargeoptimization | charge optimization | boolean | True | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
Cascade MCM10 | boiler | 121 | wwmaxpower | max power | uint (>=0<=254) | % | True | number.boiler_max_power | number.boiler_wwmaxpower |
Cascade MCM10 | boiler | 121 | wwmaxtemp | maximum temperature | uint (>=0<=70) | C | True | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
Cascade MCM10 | boiler | 121 | wwcircpump | circulation pump available | boolean | True | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
Cascade MCM10 | boiler | 121 | wwchargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
Cascade MCM10 | boiler | 121 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
Cascade MCM10 | boiler | 121 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
Cascade MCM10 | boiler | 121 | wwdisinfectiontemp | disinfection temperature | uint (>=0<=254) | C | True | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
Cascade MCM10 | boiler | 121 | wwcircmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
Cascade MCM10 | boiler | 121 | wwcirc | circulation active | boolean | True | switch.boiler_circulation_active | switch.boiler_wwcirc | |
Cascade MCM10 | boiler | 121 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
Cascade MCM10 | boiler | 121 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
Cascade MCM10 | boiler | 121 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | False | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
Cascade MCM10 | boiler | 121 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
Cascade MCM10 | boiler | 121 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
Cascade MCM10 | boiler | 121 | wwactivated | activated | boolean | True | switch.boiler_activated | switch.boiler_wwactivated | |
Cascade MCM10 | boiler | 121 | wwonetime | one time charging | boolean | True | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
Cascade MCM10 | boiler | 121 | wwdisinfecting | disinfecting | boolean | True | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
Cascade MCM10 | boiler | 121 | wwcharging | charging | boolean | False | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
Cascade MCM10 | boiler | 121 | wwrecharging | recharging | boolean | False | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
Cascade MCM10 | boiler | 121 | wwtempok | temperature ok | boolean | False | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
Cascade MCM10 | boiler | 121 | wwactive | active | boolean | False | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
Cascade MCM10 | boiler | 121 | ww3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
Cascade MCM10 | boiler | 121 | wwsetpumppower | set pump power | uint (>=0<=100) | % | False | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
Cascade MCM10 | boiler | 121 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | False | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
Cascade MCM10 | boiler | 121 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | False | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
Cascade MCM10 | boiler | 121 | wwstarts | starts | ulong (>=0<=65533) | False | sensor.boiler_starts | sensor.boiler_wwstarts | |
Cascade MCM10 | boiler | 121 | wwworkm | active time | time (>=0<=65533) | minutes | False | sensor.boiler_active_time | sensor.boiler_wwworkm |
Proline | boiler | 122 | reset | Reset | cmd [-|maintenance|error] | True | sensor.boiler_Reset | sensor.boiler_reset | |
Proline | boiler | 122 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
Proline | boiler | 122 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
Proline | boiler | 122 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
Proline | boiler | 122 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
Proline | boiler | 122 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
Proline | boiler | 122 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
Proline | boiler | 122 | rettemp | return temperature | ushort (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
Proline | boiler | 122 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
Proline | boiler | 122 | syspress | system pressure | uint (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
Proline | boiler | 122 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
Proline | boiler | 122 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
Proline | boiler | 122 | burngas | gas | boolean | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
Proline | boiler | 122 | burngas2 | gas stage 2 | boolean | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
Proline | boiler | 122 | flamecurr | flame current | ushort (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr |
Proline | boiler | 122 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
Proline | boiler | 122 | fanwork | fan | boolean | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
Proline | boiler | 122 | ignwork | ignition | boolean | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
Proline | boiler | 122 | oilpreheat | oil preheating | boolean | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
Proline | boiler | 122 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
Proline | boiler | 122 | heatingtemp | heating temperature | uint (>=0<=254) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
Proline | boiler | 122 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
Proline | boiler | 122 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
Proline | boiler | 122 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
Proline | boiler | 122 | pumpdelay | pump delay | uint (>=0<=254) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
Proline | boiler | 122 | burnminperiod | burner min period | uint (>=0<=254) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod |
Proline | boiler | 122 | burnminpower | burner min power | uint (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower |
Proline | boiler | 122 | burnmaxpower | burner max power | uint (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower |
Proline | boiler | 122 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
Proline | boiler | 122 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
Proline | boiler | 122 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
Proline | boiler | 122 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
Proline | boiler | 122 | setflowtemp | set flow temperature | uint (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
Proline | boiler | 122 | setburnpow | burner set power | uint (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
Proline | boiler | 122 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
Proline | boiler | 122 | selburnpow | burner selected max power | uint (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
Proline | boiler | 122 | curburnpow | burner current power | uint (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
Proline | boiler | 122 | burnstarts | burner starts | ulong (>=0<=65533) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
Proline | boiler | 122 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
Proline | boiler | 122 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
Proline | boiler | 122 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
Proline | boiler | 122 | heatstarts | burner starts heating | ulong (>=0<=65533) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
Proline | boiler | 122 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
Proline | boiler | 122 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
Proline | boiler | 122 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
Proline | boiler | 122 | servicecodenumber | service code number | ushort (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
Proline | boiler | 122 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
Proline | boiler | 122 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
Proline | boiler | 122 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
Proline | boiler | 122 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
Proline | boiler | 122 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
Proline | boiler | 122 | emergencytemp | emergency temperature | uint (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
Proline | boiler | 122 | wwtapactivated | turn on/off | boolean | True | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
Proline | boiler | 122 | wwsettemp | set temperature | uint (>=0<=254) | C | False | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
Proline | boiler | 122 | wwseltemp | selected temperature | uint (>=0<=254) | C | True | number.boiler_selected_temperature | number.boiler_wwseltemp |
Proline | boiler | 122 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | True | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
Proline | boiler | 122 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | False | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
Proline | boiler | 122 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | True | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
Proline | boiler | 122 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | False | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
Proline | boiler | 122 | wwtype | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_type | sensor.boiler_wwtype | |
Proline | boiler | 122 | wwcomfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_comfort | select.boiler_wwcomfort | |
Proline | boiler | 122 | wwcomfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
Proline | boiler | 122 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | True | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
Proline | boiler | 122 | wwchargeoptimization | charge optimization | boolean | True | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
Proline | boiler | 122 | wwmaxpower | max power | uint (>=0<=254) | % | True | number.boiler_max_power | number.boiler_wwmaxpower |
Proline | boiler | 122 | wwmaxtemp | maximum temperature | uint (>=0<=70) | C | True | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
Proline | boiler | 122 | wwcircpump | circulation pump available | boolean | True | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
Proline | boiler | 122 | wwchargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
Proline | boiler | 122 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
Proline | boiler | 122 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
Proline | boiler | 122 | wwdisinfectiontemp | disinfection temperature | uint (>=0<=254) | C | True | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
Proline | boiler | 122 | wwcircmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
Proline | boiler | 122 | wwcirc | circulation active | boolean | True | switch.boiler_circulation_active | switch.boiler_wwcirc | |
Proline | boiler | 122 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
Proline | boiler | 122 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
Proline | boiler | 122 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | False | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
Proline | boiler | 122 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
Proline | boiler | 122 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
Proline | boiler | 122 | wwactivated | activated | boolean | True | switch.boiler_activated | switch.boiler_wwactivated | |
Proline | boiler | 122 | wwonetime | one time charging | boolean | True | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
Proline | boiler | 122 | wwdisinfecting | disinfecting | boolean | True | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
Proline | boiler | 122 | wwcharging | charging | boolean | False | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
Proline | boiler | 122 | wwrecharging | recharging | boolean | False | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
Proline | boiler | 122 | wwtempok | temperature ok | boolean | False | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
Proline | boiler | 122 | wwactive | active | boolean | False | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
Proline | boiler | 122 | ww3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
Proline | boiler | 122 | wwsetpumppower | set pump power | uint (>=0<=100) | % | False | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
Proline | boiler | 122 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | False | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
Proline | boiler | 122 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | False | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
Proline | boiler | 122 | wwstarts | starts | ulong (>=0<=65533) | False | sensor.boiler_starts | sensor.boiler_wwstarts | |
Proline | boiler | 122 | wwworkm | active time | time (>=0<=65533) | minutes | False | sensor.boiler_active_time | sensor.boiler_wwworkm |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | reset | Reset | cmd [-|maintenance|error] | True | sensor.boiler_Reset | sensor.boiler_reset | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | rettemp | return temperature | ushort (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | syspress | system pressure | uint (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | burngas | gas | boolean | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | burngas2 | gas stage 2 | boolean | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | flamecurr | flame current | ushort (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | fanwork | fan | boolean | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | ignwork | ignition | boolean | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | oilpreheat | oil preheating | boolean | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | heatingtemp | heating temperature | uint (>=0<=254) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | pumpdelay | pump delay | uint (>=0<=254) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | burnminperiod | burner min period | uint (>=0<=254) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | burnminpower | burner min power | uint (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | burnmaxpower | burner max power | uint (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | setflowtemp | set flow temperature | uint (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | setburnpow | burner set power | uint (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | selburnpow | burner selected max power | uint (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | curburnpow | burner current power | uint (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | burnstarts | burner starts | ulong (>=0<=65533) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | heatstarts | burner starts heating | ulong (>=0<=65533) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | servicecodenumber | service code number | ushort (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | emergencytemp | emergency temperature | uint (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwtapactivated | turn on/off | boolean | True | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwsettemp | set temperature | uint (>=0<=254) | C | False | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwseltemp | selected temperature | uint (>=0<=254) | C | True | number.boiler_selected_temperature | number.boiler_wwseltemp |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | True | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | False | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | True | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | False | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwtype | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_type | sensor.boiler_wwtype | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwcomfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_comfort | select.boiler_wwcomfort | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwcomfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | True | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwchargeoptimization | charge optimization | boolean | True | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwmaxpower | max power | uint (>=0<=254) | % | True | number.boiler_max_power | number.boiler_wwmaxpower |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwmaxtemp | maximum temperature | uint (>=0<=70) | C | True | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwcircpump | circulation pump available | boolean | True | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwchargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwdisinfectiontemp | disinfection temperature | uint (>=0<=254) | C | True | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwcircmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwcirc | circulation active | boolean | True | switch.boiler_circulation_active | switch.boiler_wwcirc | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | False | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwactivated | activated | boolean | True | switch.boiler_activated | switch.boiler_wwactivated | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwonetime | one time charging | boolean | True | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwdisinfecting | disinfecting | boolean | True | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwcharging | charging | boolean | False | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwrecharging | recharging | boolean | False | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwtempok | temperature ok | boolean | False | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwactive | active | boolean | False | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | ww3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwsetpumppower | set pump power | uint (>=0<=100) | % | False | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | False | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | False | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwstarts | starts | ulong (>=0<=65533) | False | sensor.boiler_starts | sensor.boiler_wwstarts | |
GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwworkm | active time | time (>=0<=65533) | minutes | False | sensor.boiler_active_time | sensor.boiler_wwworkm |
GB212 | boiler | 131 | reset | Reset | cmd [-|maintenance|error] | True | sensor.boiler_Reset | sensor.boiler_reset | |
GB212 | boiler | 131 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
GB212 | boiler | 131 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
GB212 | boiler | 131 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
GB212 | boiler | 131 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
GB212 | boiler | 131 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
GB212 | boiler | 131 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
GB212 | boiler | 131 | rettemp | return temperature | ushort (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
GB212 | boiler | 131 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
GB212 | boiler | 131 | syspress | system pressure | uint (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
GB212 | boiler | 131 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
GB212 | boiler | 131 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
GB212 | boiler | 131 | burngas | gas | boolean | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
GB212 | boiler | 131 | burngas2 | gas stage 2 | boolean | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
GB212 | boiler | 131 | flamecurr | flame current | ushort (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr |
GB212 | boiler | 131 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
GB212 | boiler | 131 | fanwork | fan | boolean | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
GB212 | boiler | 131 | ignwork | ignition | boolean | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
GB212 | boiler | 131 | oilpreheat | oil preheating | boolean | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
GB212 | boiler | 131 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
GB212 | boiler | 131 | heatingtemp | heating temperature | uint (>=0<=254) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
GB212 | boiler | 131 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
GB212 | boiler | 131 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
GB212 | boiler | 131 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
GB212 | boiler | 131 | pumpdelay | pump delay | uint (>=0<=254) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
GB212 | boiler | 131 | burnminperiod | burner min period | uint (>=0<=254) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod |
GB212 | boiler | 131 | burnminpower | burner min power | uint (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower |
GB212 | boiler | 131 | burnmaxpower | burner max power | uint (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower |
GB212 | boiler | 131 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
GB212 | boiler | 131 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
GB212 | boiler | 131 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
GB212 | boiler | 131 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
GB212 | boiler | 131 | setflowtemp | set flow temperature | uint (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
GB212 | boiler | 131 | setburnpow | burner set power | uint (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
GB212 | boiler | 131 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
GB212 | boiler | 131 | selburnpow | burner selected max power | uint (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
GB212 | boiler | 131 | curburnpow | burner current power | uint (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
GB212 | boiler | 131 | burnstarts | burner starts | ulong (>=0<=65533) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
GB212 | boiler | 131 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
GB212 | boiler | 131 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
GB212 | boiler | 131 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
GB212 | boiler | 131 | heatstarts | burner starts heating | ulong (>=0<=65533) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
GB212 | boiler | 131 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
GB212 | boiler | 131 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
GB212 | boiler | 131 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
GB212 | boiler | 131 | servicecodenumber | service code number | ushort (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
GB212 | boiler | 131 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
GB212 | boiler | 131 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
GB212 | boiler | 131 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
GB212 | boiler | 131 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
GB212 | boiler | 131 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
GB212 | boiler | 131 | emergencytemp | emergency temperature | uint (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
GB212 | boiler | 131 | wwtapactivated | turn on/off | boolean | True | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
GB212 | boiler | 131 | wwsettemp | set temperature | uint (>=0<=254) | C | False | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
GB212 | boiler | 131 | wwseltemp | selected temperature | uint (>=0<=254) | C | True | number.boiler_selected_temperature | number.boiler_wwseltemp |
GB212 | boiler | 131 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | True | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
GB212 | boiler | 131 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | False | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
GB212 | boiler | 131 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | True | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
GB212 | boiler | 131 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | False | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
GB212 | boiler | 131 | wwtype | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_type | sensor.boiler_wwtype | |
GB212 | boiler | 131 | wwcomfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_comfort | select.boiler_wwcomfort | |
GB212 | boiler | 131 | wwcomfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
GB212 | boiler | 131 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | True | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
GB212 | boiler | 131 | wwchargeoptimization | charge optimization | boolean | True | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
GB212 | boiler | 131 | wwmaxpower | max power | uint (>=0<=254) | % | True | number.boiler_max_power | number.boiler_wwmaxpower |
GB212 | boiler | 131 | wwmaxtemp | maximum temperature | uint (>=0<=70) | C | True | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
GB212 | boiler | 131 | wwcircpump | circulation pump available | boolean | True | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
GB212 | boiler | 131 | wwchargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
GB212 | boiler | 131 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
GB212 | boiler | 131 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
GB212 | boiler | 131 | wwdisinfectiontemp | disinfection temperature | uint (>=0<=254) | C | True | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
GB212 | boiler | 131 | wwcircmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
GB212 | boiler | 131 | wwcirc | circulation active | boolean | True | switch.boiler_circulation_active | switch.boiler_wwcirc | |
GB212 | boiler | 131 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
GB212 | boiler | 131 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
GB212 | boiler | 131 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | False | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
GB212 | boiler | 131 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
GB212 | boiler | 131 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
GB212 | boiler | 131 | wwactivated | activated | boolean | True | switch.boiler_activated | switch.boiler_wwactivated | |
GB212 | boiler | 131 | wwonetime | one time charging | boolean | True | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
GB212 | boiler | 131 | wwdisinfecting | disinfecting | boolean | True | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
GB212 | boiler | 131 | wwcharging | charging | boolean | False | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
GB212 | boiler | 131 | wwrecharging | recharging | boolean | False | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
GB212 | boiler | 131 | wwtempok | temperature ok | boolean | False | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
GB212 | boiler | 131 | wwactive | active | boolean | False | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
GB212 | boiler | 131 | ww3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
GB212 | boiler | 131 | wwsetpumppower | set pump power | uint (>=0<=100) | % | False | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
GB212 | boiler | 131 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | False | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
GB212 | boiler | 131 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | False | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
GB212 | boiler | 131 | wwstarts | starts | ulong (>=0<=65533) | False | sensor.boiler_starts | sensor.boiler_wwstarts | |
GB212 | boiler | 131 | wwworkm | active time | time (>=0<=65533) | minutes | False | sensor.boiler_active_time | sensor.boiler_wwworkm |
GC7000F | boiler | 132 | reset | Reset | cmd [-|maintenance|error] | True | sensor.boiler_Reset | sensor.boiler_reset | |
GC7000F | boiler | 132 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
GC7000F | boiler | 132 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
GC7000F | boiler | 132 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
GC7000F | boiler | 132 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
GC7000F | boiler | 132 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
GC7000F | boiler | 132 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
GC7000F | boiler | 132 | rettemp | return temperature | ushort (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
GC7000F | boiler | 132 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
GC7000F | boiler | 132 | syspress | system pressure | uint (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
GC7000F | boiler | 132 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
GC7000F | boiler | 132 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
GC7000F | boiler | 132 | burngas | gas | boolean | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
GC7000F | boiler | 132 | burngas2 | gas stage 2 | boolean | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
GC7000F | boiler | 132 | flamecurr | flame current | ushort (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr |
GC7000F | boiler | 132 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
GC7000F | boiler | 132 | fanwork | fan | boolean | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
GC7000F | boiler | 132 | ignwork | ignition | boolean | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
GC7000F | boiler | 132 | oilpreheat | oil preheating | boolean | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
GC7000F | boiler | 132 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
GC7000F | boiler | 132 | heatingtemp | heating temperature | uint (>=0<=254) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
GC7000F | boiler | 132 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
GC7000F | boiler | 132 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
GC7000F | boiler | 132 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
GC7000F | boiler | 132 | pumpdelay | pump delay | uint (>=0<=254) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
GC7000F | boiler | 132 | burnminperiod | burner min period | uint (>=0<=254) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod |
GC7000F | boiler | 132 | burnminpower | burner min power | uint (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower |
GC7000F | boiler | 132 | burnmaxpower | burner max power | uint (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower |
GC7000F | boiler | 132 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
GC7000F | boiler | 132 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
GC7000F | boiler | 132 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
GC7000F | boiler | 132 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
GC7000F | boiler | 132 | setflowtemp | set flow temperature | uint (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
GC7000F | boiler | 132 | setburnpow | burner set power | uint (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
GC7000F | boiler | 132 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
GC7000F | boiler | 132 | selburnpow | burner selected max power | uint (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
GC7000F | boiler | 132 | curburnpow | burner current power | uint (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
GC7000F | boiler | 132 | burnstarts | burner starts | ulong (>=0<=65533) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
GC7000F | boiler | 132 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
GC7000F | boiler | 132 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
GC7000F | boiler | 132 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
GC7000F | boiler | 132 | heatstarts | burner starts heating | ulong (>=0<=65533) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
GC7000F | boiler | 132 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
GC7000F | boiler | 132 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
GC7000F | boiler | 132 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
GC7000F | boiler | 132 | servicecodenumber | service code number | ushort (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
GC7000F | boiler | 132 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
GC7000F | boiler | 132 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
GC7000F | boiler | 132 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
GC7000F | boiler | 132 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
GC7000F | boiler | 132 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
GC7000F | boiler | 132 | emergencytemp | emergency temperature | uint (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
GC7000F | boiler | 132 | wwtapactivated | turn on/off | boolean | True | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
GC7000F | boiler | 132 | wwsettemp | set temperature | uint (>=0<=254) | C | False | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
GC7000F | boiler | 132 | wwseltemp | selected temperature | uint (>=0<=254) | C | True | number.boiler_selected_temperature | number.boiler_wwseltemp |
GC7000F | boiler | 132 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | True | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
GC7000F | boiler | 132 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | False | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
GC7000F | boiler | 132 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | True | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
GC7000F | boiler | 132 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | False | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
GC7000F | boiler | 132 | wwtype | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_type | sensor.boiler_wwtype | |
GC7000F | boiler | 132 | wwcomfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_comfort | select.boiler_wwcomfort | |
GC7000F | boiler | 132 | wwcomfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
GC7000F | boiler | 132 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | True | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
GC7000F | boiler | 132 | wwchargeoptimization | charge optimization | boolean | True | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
GC7000F | boiler | 132 | wwmaxpower | max power | uint (>=0<=254) | % | True | number.boiler_max_power | number.boiler_wwmaxpower |
GC7000F | boiler | 132 | wwmaxtemp | maximum temperature | uint (>=0<=70) | C | True | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
GC7000F | boiler | 132 | wwcircpump | circulation pump available | boolean | True | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
GC7000F | boiler | 132 | wwchargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
GC7000F | boiler | 132 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
GC7000F | boiler | 132 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
GC7000F | boiler | 132 | wwdisinfectiontemp | disinfection temperature | uint (>=0<=254) | C | True | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
GC7000F | boiler | 132 | wwcircmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
GC7000F | boiler | 132 | wwcirc | circulation active | boolean | True | switch.boiler_circulation_active | switch.boiler_wwcirc | |
GC7000F | boiler | 132 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
GC7000F | boiler | 132 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
GC7000F | boiler | 132 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | False | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
GC7000F | boiler | 132 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
GC7000F | boiler | 132 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
GC7000F | boiler | 132 | wwactivated | activated | boolean | True | switch.boiler_activated | switch.boiler_wwactivated | |
GC7000F | boiler | 132 | wwonetime | one time charging | boolean | True | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
GC7000F | boiler | 132 | wwdisinfecting | disinfecting | boolean | True | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
GC7000F | boiler | 132 | wwcharging | charging | boolean | False | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
GC7000F | boiler | 132 | wwrecharging | recharging | boolean | False | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
GC7000F | boiler | 132 | wwtempok | temperature ok | boolean | False | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
GC7000F | boiler | 132 | wwactive | active | boolean | False | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
GC7000F | boiler | 132 | ww3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
GC7000F | boiler | 132 | wwsetpumppower | set pump power | uint (>=0<=100) | % | False | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
GC7000F | boiler | 132 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | False | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
GC7000F | boiler | 132 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | False | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
GC7000F | boiler | 132 | wwstarts | starts | ulong (>=0<=65533) | False | sensor.boiler_starts | sensor.boiler_wwstarts | |
GC7000F | boiler | 132 | wwworkm | active time | time (>=0<=65533) | minutes | False | sensor.boiler_active_time | sensor.boiler_wwworkm |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | reset | Reset | cmd [-|maintenance|error] | True | sensor.boiler_Reset | sensor.boiler_reset | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | rettemp | return temperature | ushort (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | syspress | system pressure | uint (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | burngas | gas | boolean | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | burngas2 | gas stage 2 | boolean | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | flamecurr | flame current | ushort (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | fanwork | fan | boolean | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | ignwork | ignition | boolean | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | oilpreheat | oil preheating | boolean | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | heatingtemp | heating temperature | uint (>=0<=254) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | pumpdelay | pump delay | uint (>=0<=254) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | burnminperiod | burner min period | uint (>=0<=254) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | burnminpower | burner min power | uint (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | burnmaxpower | burner max power | uint (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | setflowtemp | set flow temperature | uint (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | setburnpow | burner set power | uint (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | selburnpow | burner selected max power | uint (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | curburnpow | burner current power | uint (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | burnstarts | burner starts | ulong (>=0<=65533) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | heatstarts | burner starts heating | ulong (>=0<=65533) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | servicecodenumber | service code number | ushort (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | emergencytemp | emergency temperature | uint (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwtapactivated | turn on/off | boolean | True | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwsettemp | set temperature | uint (>=0<=254) | C | False | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwseltemp | selected temperature | uint (>=0<=254) | C | True | number.boiler_selected_temperature | number.boiler_wwseltemp |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | True | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | False | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | True | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | False | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwtype | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_type | sensor.boiler_wwtype | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwcomfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_comfort | select.boiler_wwcomfort | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwcomfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | True | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwchargeoptimization | charge optimization | boolean | True | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwmaxpower | max power | uint (>=0<=254) | % | True | number.boiler_max_power | number.boiler_wwmaxpower |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwmaxtemp | maximum temperature | uint (>=0<=70) | C | True | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwcircpump | circulation pump available | boolean | True | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwchargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwdisinfectiontemp | disinfection temperature | uint (>=0<=254) | C | True | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwcircmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwcirc | circulation active | boolean | True | switch.boiler_circulation_active | switch.boiler_wwcirc | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | False | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwactivated | activated | boolean | True | switch.boiler_activated | switch.boiler_wwactivated | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwonetime | one time charging | boolean | True | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwdisinfecting | disinfecting | boolean | True | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwcharging | charging | boolean | False | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwrecharging | recharging | boolean | False | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwtempok | temperature ok | boolean | False | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwactive | active | boolean | False | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | ww3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwsetpumppower | set pump power | uint (>=0<=100) | % | False | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | False | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | False | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwstarts | starts | ulong (>=0<=65533) | False | sensor.boiler_starts | sensor.boiler_wwstarts | |
Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwworkm | active time | time (>=0<=65533) | minutes | False | sensor.boiler_active_time | sensor.boiler_wwworkm |
Greenstar 30Ri Compact | boiler | 154 | reset | Reset | cmd [-|maintenance|error] | True | sensor.boiler_Reset | sensor.boiler_reset | |
Greenstar 30Ri Compact | boiler | 154 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
Greenstar 30Ri Compact | boiler | 154 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
Greenstar 30Ri Compact | boiler | 154 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
Greenstar 30Ri Compact | boiler | 154 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
Greenstar 30Ri Compact | boiler | 154 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
Greenstar 30Ri Compact | boiler | 154 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
Greenstar 30Ri Compact | boiler | 154 | rettemp | return temperature | ushort (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
Greenstar 30Ri Compact | boiler | 154 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
Greenstar 30Ri Compact | boiler | 154 | syspress | system pressure | uint (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
Greenstar 30Ri Compact | boiler | 154 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
Greenstar 30Ri Compact | boiler | 154 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
Greenstar 30Ri Compact | boiler | 154 | burngas | gas | boolean | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
Greenstar 30Ri Compact | boiler | 154 | burngas2 | gas stage 2 | boolean | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
Greenstar 30Ri Compact | boiler | 154 | flamecurr | flame current | ushort (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr |
Greenstar 30Ri Compact | boiler | 154 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
Greenstar 30Ri Compact | boiler | 154 | fanwork | fan | boolean | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
Greenstar 30Ri Compact | boiler | 154 | ignwork | ignition | boolean | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
Greenstar 30Ri Compact | boiler | 154 | oilpreheat | oil preheating | boolean | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
Greenstar 30Ri Compact | boiler | 154 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
Greenstar 30Ri Compact | boiler | 154 | heatingtemp | heating temperature | uint (>=0<=254) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
Greenstar 30Ri Compact | boiler | 154 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
Greenstar 30Ri Compact | boiler | 154 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
Greenstar 30Ri Compact | boiler | 154 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
Greenstar 30Ri Compact | boiler | 154 | pumpdelay | pump delay | uint (>=0<=254) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
Greenstar 30Ri Compact | boiler | 154 | burnminperiod | burner min period | uint (>=0<=254) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod |
Greenstar 30Ri Compact | boiler | 154 | burnminpower | burner min power | uint (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower |
Greenstar 30Ri Compact | boiler | 154 | burnmaxpower | burner max power | uint (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower |
Greenstar 30Ri Compact | boiler | 154 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
Greenstar 30Ri Compact | boiler | 154 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
Greenstar 30Ri Compact | boiler | 154 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
Greenstar 30Ri Compact | boiler | 154 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
Greenstar 30Ri Compact | boiler | 154 | setflowtemp | set flow temperature | uint (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
Greenstar 30Ri Compact | boiler | 154 | setburnpow | burner set power | uint (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
Greenstar 30Ri Compact | boiler | 154 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
Greenstar 30Ri Compact | boiler | 154 | selburnpow | burner selected max power | uint (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
Greenstar 30Ri Compact | boiler | 154 | curburnpow | burner current power | uint (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
Greenstar 30Ri Compact | boiler | 154 | burnstarts | burner starts | ulong (>=0<=65533) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
Greenstar 30Ri Compact | boiler | 154 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
Greenstar 30Ri Compact | boiler | 154 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
Greenstar 30Ri Compact | boiler | 154 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
Greenstar 30Ri Compact | boiler | 154 | heatstarts | burner starts heating | ulong (>=0<=65533) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
Greenstar 30Ri Compact | boiler | 154 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
Greenstar 30Ri Compact | boiler | 154 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
Greenstar 30Ri Compact | boiler | 154 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
Greenstar 30Ri Compact | boiler | 154 | servicecodenumber | service code number | ushort (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
Greenstar 30Ri Compact | boiler | 154 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
Greenstar 30Ri Compact | boiler | 154 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
Greenstar 30Ri Compact | boiler | 154 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
Greenstar 30Ri Compact | boiler | 154 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
Greenstar 30Ri Compact | boiler | 154 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
Greenstar 30Ri Compact | boiler | 154 | emergencytemp | emergency temperature | uint (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
Greenstar 30Ri Compact | boiler | 154 | wwtapactivated | turn on/off | boolean | True | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
Greenstar 30Ri Compact | boiler | 154 | wwsettemp | set temperature | uint (>=0<=254) | C | False | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
Greenstar 30Ri Compact | boiler | 154 | wwseltemp | selected temperature | uint (>=0<=254) | C | True | number.boiler_selected_temperature | number.boiler_wwseltemp |
Greenstar 30Ri Compact | boiler | 154 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | True | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
Greenstar 30Ri Compact | boiler | 154 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | False | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
Greenstar 30Ri Compact | boiler | 154 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | True | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
Greenstar 30Ri Compact | boiler | 154 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | False | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
Greenstar 30Ri Compact | boiler | 154 | wwtype | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_type | sensor.boiler_wwtype | |
Greenstar 30Ri Compact | boiler | 154 | wwcomfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_comfort | select.boiler_wwcomfort | |
Greenstar 30Ri Compact | boiler | 154 | wwcomfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
Greenstar 30Ri Compact | boiler | 154 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | True | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
Greenstar 30Ri Compact | boiler | 154 | wwchargeoptimization | charge optimization | boolean | True | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
Greenstar 30Ri Compact | boiler | 154 | wwmaxpower | max power | uint (>=0<=254) | % | True | number.boiler_max_power | number.boiler_wwmaxpower |
Greenstar 30Ri Compact | boiler | 154 | wwmaxtemp | maximum temperature | uint (>=0<=70) | C | True | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
Greenstar 30Ri Compact | boiler | 154 | wwcircpump | circulation pump available | boolean | True | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
Greenstar 30Ri Compact | boiler | 154 | wwchargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
Greenstar 30Ri Compact | boiler | 154 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
Greenstar 30Ri Compact | boiler | 154 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
Greenstar 30Ri Compact | boiler | 154 | wwdisinfectiontemp | disinfection temperature | uint (>=0<=254) | C | True | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
Greenstar 30Ri Compact | boiler | 154 | wwcircmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
Greenstar 30Ri Compact | boiler | 154 | wwcirc | circulation active | boolean | True | switch.boiler_circulation_active | switch.boiler_wwcirc | |
Greenstar 30Ri Compact | boiler | 154 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
Greenstar 30Ri Compact | boiler | 154 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
Greenstar 30Ri Compact | boiler | 154 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | False | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
Greenstar 30Ri Compact | boiler | 154 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
Greenstar 30Ri Compact | boiler | 154 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
Greenstar 30Ri Compact | boiler | 154 | wwactivated | activated | boolean | True | switch.boiler_activated | switch.boiler_wwactivated | |
Greenstar 30Ri Compact | boiler | 154 | wwonetime | one time charging | boolean | True | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
Greenstar 30Ri Compact | boiler | 154 | wwdisinfecting | disinfecting | boolean | True | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
Greenstar 30Ri Compact | boiler | 154 | wwcharging | charging | boolean | False | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
Greenstar 30Ri Compact | boiler | 154 | wwrecharging | recharging | boolean | False | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
Greenstar 30Ri Compact | boiler | 154 | wwtempok | temperature ok | boolean | False | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
Greenstar 30Ri Compact | boiler | 154 | wwactive | active | boolean | False | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
Greenstar 30Ri Compact | boiler | 154 | ww3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
Greenstar 30Ri Compact | boiler | 154 | wwsetpumppower | set pump power | uint (>=0<=100) | % | False | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
Greenstar 30Ri Compact | boiler | 154 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | False | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
Greenstar 30Ri Compact | boiler | 154 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | False | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
Greenstar 30Ri Compact | boiler | 154 | wwstarts | starts | ulong (>=0<=65533) | False | sensor.boiler_starts | sensor.boiler_wwstarts | |
Greenstar 30Ri Compact | boiler | 154 | wwworkm | active time | time (>=0<=65533) | minutes | False | sensor.boiler_active_time | sensor.boiler_wwworkm |
Cerapur Aero | boiler | 167 | reset | Reset | cmd [-|maintenance|error] | True | sensor.boiler_Reset | sensor.boiler_reset | |
Cerapur Aero | boiler | 167 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
Cerapur Aero | boiler | 167 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
Cerapur Aero | boiler | 167 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
Cerapur Aero | boiler | 167 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
Cerapur Aero | boiler | 167 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
Cerapur Aero | boiler | 167 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
Cerapur Aero | boiler | 167 | rettemp | return temperature | ushort (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
Cerapur Aero | boiler | 167 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
Cerapur Aero | boiler | 167 | syspress | system pressure | uint (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
Cerapur Aero | boiler | 167 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
Cerapur Aero | boiler | 167 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
Cerapur Aero | boiler | 167 | burngas | gas | boolean | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
Cerapur Aero | boiler | 167 | burngas2 | gas stage 2 | boolean | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
Cerapur Aero | boiler | 167 | flamecurr | flame current | ushort (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr |
Cerapur Aero | boiler | 167 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
Cerapur Aero | boiler | 167 | fanwork | fan | boolean | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
Cerapur Aero | boiler | 167 | ignwork | ignition | boolean | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
Cerapur Aero | boiler | 167 | oilpreheat | oil preheating | boolean | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
Cerapur Aero | boiler | 167 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
Cerapur Aero | boiler | 167 | heatingtemp | heating temperature | uint (>=0<=254) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
Cerapur Aero | boiler | 167 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
Cerapur Aero | boiler | 167 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
Cerapur Aero | boiler | 167 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
Cerapur Aero | boiler | 167 | pumpdelay | pump delay | uint (>=0<=254) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
Cerapur Aero | boiler | 167 | burnminperiod | burner min period | uint (>=0<=254) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod |
Cerapur Aero | boiler | 167 | burnminpower | burner min power | uint (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower |
Cerapur Aero | boiler | 167 | burnmaxpower | burner max power | uint (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower |
Cerapur Aero | boiler | 167 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
Cerapur Aero | boiler | 167 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
Cerapur Aero | boiler | 167 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
Cerapur Aero | boiler | 167 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
Cerapur Aero | boiler | 167 | setflowtemp | set flow temperature | uint (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
Cerapur Aero | boiler | 167 | setburnpow | burner set power | uint (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
Cerapur Aero | boiler | 167 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
Cerapur Aero | boiler | 167 | selburnpow | burner selected max power | uint (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
Cerapur Aero | boiler | 167 | curburnpow | burner current power | uint (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
Cerapur Aero | boiler | 167 | burnstarts | burner starts | ulong (>=0<=65533) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
Cerapur Aero | boiler | 167 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
Cerapur Aero | boiler | 167 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
Cerapur Aero | boiler | 167 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
Cerapur Aero | boiler | 167 | heatstarts | burner starts heating | ulong (>=0<=65533) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
Cerapur Aero | boiler | 167 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
Cerapur Aero | boiler | 167 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
Cerapur Aero | boiler | 167 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
Cerapur Aero | boiler | 167 | servicecodenumber | service code number | ushort (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
Cerapur Aero | boiler | 167 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
Cerapur Aero | boiler | 167 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
Cerapur Aero | boiler | 167 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
Cerapur Aero | boiler | 167 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
Cerapur Aero | boiler | 167 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
Cerapur Aero | boiler | 167 | emergencytemp | emergency temperature | uint (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
Cerapur Aero | boiler | 167 | wwtapactivated | turn on/off | boolean | True | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
Cerapur Aero | boiler | 167 | wwsettemp | set temperature | uint (>=0<=254) | C | False | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
Cerapur Aero | boiler | 167 | wwseltemp | selected temperature | uint (>=0<=254) | C | True | number.boiler_selected_temperature | number.boiler_wwseltemp |
Cerapur Aero | boiler | 167 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | True | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
Cerapur Aero | boiler | 167 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | False | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
Cerapur Aero | boiler | 167 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | True | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
Cerapur Aero | boiler | 167 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | False | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
Cerapur Aero | boiler | 167 | wwtype | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_type | sensor.boiler_wwtype | |
Cerapur Aero | boiler | 167 | wwcomfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_comfort | select.boiler_wwcomfort | |
Cerapur Aero | boiler | 167 | wwcomfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
Cerapur Aero | boiler | 167 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | True | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
Cerapur Aero | boiler | 167 | wwchargeoptimization | charge optimization | boolean | True | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
Cerapur Aero | boiler | 167 | wwmaxpower | max power | uint (>=0<=254) | % | True | number.boiler_max_power | number.boiler_wwmaxpower |
Cerapur Aero | boiler | 167 | wwmaxtemp | maximum temperature | uint (>=0<=70) | C | True | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
Cerapur Aero | boiler | 167 | wwcircpump | circulation pump available | boolean | True | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
Cerapur Aero | boiler | 167 | wwchargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
Cerapur Aero | boiler | 167 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
Cerapur Aero | boiler | 167 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
Cerapur Aero | boiler | 167 | wwdisinfectiontemp | disinfection temperature | uint (>=0<=254) | C | True | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
Cerapur Aero | boiler | 167 | wwcircmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
Cerapur Aero | boiler | 167 | wwcirc | circulation active | boolean | True | switch.boiler_circulation_active | switch.boiler_wwcirc | |
Cerapur Aero | boiler | 167 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
Cerapur Aero | boiler | 167 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
Cerapur Aero | boiler | 167 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | False | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
Cerapur Aero | boiler | 167 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
Cerapur Aero | boiler | 167 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
Cerapur Aero | boiler | 167 | wwactivated | activated | boolean | True | switch.boiler_activated | switch.boiler_wwactivated | |
Cerapur Aero | boiler | 167 | wwonetime | one time charging | boolean | True | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
Cerapur Aero | boiler | 167 | wwdisinfecting | disinfecting | boolean | True | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
Cerapur Aero | boiler | 167 | wwcharging | charging | boolean | False | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
Cerapur Aero | boiler | 167 | wwrecharging | recharging | boolean | False | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
Cerapur Aero | boiler | 167 | wwtempok | temperature ok | boolean | False | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
Cerapur Aero | boiler | 167 | wwactive | active | boolean | False | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
Cerapur Aero | boiler | 167 | ww3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
Cerapur Aero | boiler | 167 | wwsetpumppower | set pump power | uint (>=0<=100) | % | False | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
Cerapur Aero | boiler | 167 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | False | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
Cerapur Aero | boiler | 167 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | False | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
Cerapur Aero | boiler | 167 | wwstarts | starts | ulong (>=0<=65533) | False | sensor.boiler_starts | sensor.boiler_wwstarts | |
Cerapur Aero | boiler | 167 | wwworkm | active time | time (>=0<=65533) | minutes | False | sensor.boiler_active_time | sensor.boiler_wwworkm |
Hybrid Heatpump | boiler | 168 | reset | Reset | cmd [-|maintenance|error] | True | sensor.boiler_Reset | sensor.boiler_reset | |
Hybrid Heatpump | boiler | 168 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
Hybrid Heatpump | boiler | 168 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
Hybrid Heatpump | boiler | 168 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
Hybrid Heatpump | boiler | 168 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
Hybrid Heatpump | boiler | 168 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
Hybrid Heatpump | boiler | 168 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
Hybrid Heatpump | boiler | 168 | rettemp | return temperature | ushort (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
Hybrid Heatpump | boiler | 168 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
Hybrid Heatpump | boiler | 168 | syspress | system pressure | uint (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
Hybrid Heatpump | boiler | 168 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
Hybrid Heatpump | boiler | 168 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
Hybrid Heatpump | boiler | 168 | burngas | gas | boolean | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
Hybrid Heatpump | boiler | 168 | burngas2 | gas stage 2 | boolean | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
Hybrid Heatpump | boiler | 168 | flamecurr | flame current | ushort (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr |
Hybrid Heatpump | boiler | 168 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
Hybrid Heatpump | boiler | 168 | fanwork | fan | boolean | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
Hybrid Heatpump | boiler | 168 | ignwork | ignition | boolean | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
Hybrid Heatpump | boiler | 168 | oilpreheat | oil preheating | boolean | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
Hybrid Heatpump | boiler | 168 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
Hybrid Heatpump | boiler | 168 | heatingtemp | heating temperature | uint (>=0<=254) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
Hybrid Heatpump | boiler | 168 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
Hybrid Heatpump | boiler | 168 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
Hybrid Heatpump | boiler | 168 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
Hybrid Heatpump | boiler | 168 | pumpdelay | pump delay | uint (>=0<=254) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
Hybrid Heatpump | boiler | 168 | burnminperiod | burner min period | uint (>=0<=254) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod |
Hybrid Heatpump | boiler | 168 | burnminpower | burner min power | uint (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower |
Hybrid Heatpump | boiler | 168 | burnmaxpower | burner max power | uint (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower |
Hybrid Heatpump | boiler | 168 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
Hybrid Heatpump | boiler | 168 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
Hybrid Heatpump | boiler | 168 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
Hybrid Heatpump | boiler | 168 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
Hybrid Heatpump | boiler | 168 | setflowtemp | set flow temperature | uint (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
Hybrid Heatpump | boiler | 168 | setburnpow | burner set power | uint (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
Hybrid Heatpump | boiler | 168 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
Hybrid Heatpump | boiler | 168 | selburnpow | burner selected max power | uint (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
Hybrid Heatpump | boiler | 168 | curburnpow | burner current power | uint (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
Hybrid Heatpump | boiler | 168 | burnstarts | burner starts | ulong (>=0<=65533) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
Hybrid Heatpump | boiler | 168 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
Hybrid Heatpump | boiler | 168 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
Hybrid Heatpump | boiler | 168 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
Hybrid Heatpump | boiler | 168 | heatstarts | burner starts heating | ulong (>=0<=65533) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
Hybrid Heatpump | boiler | 168 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
Hybrid Heatpump | boiler | 168 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
Hybrid Heatpump | boiler | 168 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
Hybrid Heatpump | boiler | 168 | servicecodenumber | service code number | ushort (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
Hybrid Heatpump | boiler | 168 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
Hybrid Heatpump | boiler | 168 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
Hybrid Heatpump | boiler | 168 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
Hybrid Heatpump | boiler | 168 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
Hybrid Heatpump | boiler | 168 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
Hybrid Heatpump | boiler | 168 | emergencytemp | emergency temperature | uint (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
Hybrid Heatpump | boiler | 168 | wwtapactivated | turn on/off | boolean | True | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
Hybrid Heatpump | boiler | 168 | wwsettemp | set temperature | uint (>=0<=254) | C | False | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
Hybrid Heatpump | boiler | 168 | wwseltemp | selected temperature | uint (>=0<=254) | C | True | number.boiler_selected_temperature | number.boiler_wwseltemp |
Hybrid Heatpump | boiler | 168 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | True | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
Hybrid Heatpump | boiler | 168 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | False | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
Hybrid Heatpump | boiler | 168 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | True | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
Hybrid Heatpump | boiler | 168 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | False | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
Hybrid Heatpump | boiler | 168 | wwtype | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_type | sensor.boiler_wwtype | |
Hybrid Heatpump | boiler | 168 | wwcomfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_comfort | select.boiler_wwcomfort | |
Hybrid Heatpump | boiler | 168 | wwcomfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
Hybrid Heatpump | boiler | 168 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | True | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
Hybrid Heatpump | boiler | 168 | wwchargeoptimization | charge optimization | boolean | True | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
Hybrid Heatpump | boiler | 168 | wwmaxpower | max power | uint (>=0<=254) | % | True | number.boiler_max_power | number.boiler_wwmaxpower |
Hybrid Heatpump | boiler | 168 | wwmaxtemp | maximum temperature | uint (>=0<=70) | C | True | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
Hybrid Heatpump | boiler | 168 | wwcircpump | circulation pump available | boolean | True | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
Hybrid Heatpump | boiler | 168 | wwchargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
Hybrid Heatpump | boiler | 168 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
Hybrid Heatpump | boiler | 168 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
Hybrid Heatpump | boiler | 168 | wwdisinfectiontemp | disinfection temperature | uint (>=0<=254) | C | True | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
Hybrid Heatpump | boiler | 168 | wwcircmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
Hybrid Heatpump | boiler | 168 | wwcirc | circulation active | boolean | True | switch.boiler_circulation_active | switch.boiler_wwcirc | |
Hybrid Heatpump | boiler | 168 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
Hybrid Heatpump | boiler | 168 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
Hybrid Heatpump | boiler | 168 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | False | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
Hybrid Heatpump | boiler | 168 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
Hybrid Heatpump | boiler | 168 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
Hybrid Heatpump | boiler | 168 | wwactivated | activated | boolean | True | switch.boiler_activated | switch.boiler_wwactivated | |
Hybrid Heatpump | boiler | 168 | wwonetime | one time charging | boolean | True | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
Hybrid Heatpump | boiler | 168 | wwdisinfecting | disinfecting | boolean | True | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
Hybrid Heatpump | boiler | 168 | wwcharging | charging | boolean | False | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
Hybrid Heatpump | boiler | 168 | wwrecharging | recharging | boolean | False | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
Hybrid Heatpump | boiler | 168 | wwtempok | temperature ok | boolean | False | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
Hybrid Heatpump | boiler | 168 | wwactive | active | boolean | False | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
Hybrid Heatpump | boiler | 168 | ww3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
Hybrid Heatpump | boiler | 168 | wwsetpumppower | set pump power | uint (>=0<=100) | % | False | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
Hybrid Heatpump | boiler | 168 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | False | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
Hybrid Heatpump | boiler | 168 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | False | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
Hybrid Heatpump | boiler | 168 | wwstarts | starts | ulong (>=0<=65533) | False | sensor.boiler_starts | sensor.boiler_wwstarts | |
Hybrid Heatpump | boiler | 168 | wwworkm | active time | time (>=0<=65533) | minutes | False | sensor.boiler_active_time | sensor.boiler_wwworkm |
Logano GB212 | boiler | 170 | reset | Reset | cmd [-|maintenance|error] | True | sensor.boiler_Reset | sensor.boiler_reset | |
Logano GB212 | boiler | 170 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
Logano GB212 | boiler | 170 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
Logano GB212 | boiler | 170 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
Logano GB212 | boiler | 170 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
Logano GB212 | boiler | 170 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
Logano GB212 | boiler | 170 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
Logano GB212 | boiler | 170 | rettemp | return temperature | ushort (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
Logano GB212 | boiler | 170 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
Logano GB212 | boiler | 170 | syspress | system pressure | uint (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
Logano GB212 | boiler | 170 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
Logano GB212 | boiler | 170 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
Logano GB212 | boiler | 170 | burngas | gas | boolean | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
Logano GB212 | boiler | 170 | burngas2 | gas stage 2 | boolean | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
Logano GB212 | boiler | 170 | flamecurr | flame current | ushort (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr |
Logano GB212 | boiler | 170 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
Logano GB212 | boiler | 170 | fanwork | fan | boolean | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
Logano GB212 | boiler | 170 | ignwork | ignition | boolean | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
Logano GB212 | boiler | 170 | oilpreheat | oil preheating | boolean | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
Logano GB212 | boiler | 170 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
Logano GB212 | boiler | 170 | heatingtemp | heating temperature | uint (>=0<=254) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
Logano GB212 | boiler | 170 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
Logano GB212 | boiler | 170 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
Logano GB212 | boiler | 170 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
Logano GB212 | boiler | 170 | pumpdelay | pump delay | uint (>=0<=254) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
Logano GB212 | boiler | 170 | burnminperiod | burner min period | uint (>=0<=254) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod |
Logano GB212 | boiler | 170 | burnminpower | burner min power | uint (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower |
Logano GB212 | boiler | 170 | burnmaxpower | burner max power | uint (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower |
Logano GB212 | boiler | 170 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
Logano GB212 | boiler | 170 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
Logano GB212 | boiler | 170 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
Logano GB212 | boiler | 170 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
Logano GB212 | boiler | 170 | setflowtemp | set flow temperature | uint (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
Logano GB212 | boiler | 170 | setburnpow | burner set power | uint (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
Logano GB212 | boiler | 170 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
Logano GB212 | boiler | 170 | selburnpow | burner selected max power | uint (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
Logano GB212 | boiler | 170 | curburnpow | burner current power | uint (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
Logano GB212 | boiler | 170 | burnstarts | burner starts | ulong (>=0<=65533) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
Logano GB212 | boiler | 170 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
Logano GB212 | boiler | 170 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
Logano GB212 | boiler | 170 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
Logano GB212 | boiler | 170 | heatstarts | burner starts heating | ulong (>=0<=65533) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
Logano GB212 | boiler | 170 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
Logano GB212 | boiler | 170 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
Logano GB212 | boiler | 170 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
Logano GB212 | boiler | 170 | servicecodenumber | service code number | ushort (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
Logano GB212 | boiler | 170 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
Logano GB212 | boiler | 170 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
Logano GB212 | boiler | 170 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
Logano GB212 | boiler | 170 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
Logano GB212 | boiler | 170 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
Logano GB212 | boiler | 170 | emergencytemp | emergency temperature | uint (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
Logano GB212 | boiler | 170 | wwtapactivated | turn on/off | boolean | True | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
Logano GB212 | boiler | 170 | wwsettemp | set temperature | uint (>=0<=254) | C | False | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
Logano GB212 | boiler | 170 | wwseltemp | selected temperature | uint (>=0<=254) | C | True | number.boiler_selected_temperature | number.boiler_wwseltemp |
Logano GB212 | boiler | 170 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | True | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
Logano GB212 | boiler | 170 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | False | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
Logano GB212 | boiler | 170 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | True | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
Logano GB212 | boiler | 170 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | False | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
Logano GB212 | boiler | 170 | wwtype | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_type | sensor.boiler_wwtype | |
Logano GB212 | boiler | 170 | wwcomfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_comfort | select.boiler_wwcomfort | |
Logano GB212 | boiler | 170 | wwcomfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
Logano GB212 | boiler | 170 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | True | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
Logano GB212 | boiler | 170 | wwchargeoptimization | charge optimization | boolean | True | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
Logano GB212 | boiler | 170 | wwmaxpower | max power | uint (>=0<=254) | % | True | number.boiler_max_power | number.boiler_wwmaxpower |
Logano GB212 | boiler | 170 | wwmaxtemp | maximum temperature | uint (>=0<=70) | C | True | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
Logano GB212 | boiler | 170 | wwcircpump | circulation pump available | boolean | True | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
Logano GB212 | boiler | 170 | wwchargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
Logano GB212 | boiler | 170 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
Logano GB212 | boiler | 170 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
Logano GB212 | boiler | 170 | wwdisinfectiontemp | disinfection temperature | uint (>=0<=254) | C | True | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
Logano GB212 | boiler | 170 | wwcircmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
Logano GB212 | boiler | 170 | wwcirc | circulation active | boolean | True | switch.boiler_circulation_active | switch.boiler_wwcirc | |
Logano GB212 | boiler | 170 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
Logano GB212 | boiler | 170 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
Logano GB212 | boiler | 170 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | False | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
Logano GB212 | boiler | 170 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
Logano GB212 | boiler | 170 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
Logano GB212 | boiler | 170 | wwactivated | activated | boolean | True | switch.boiler_activated | switch.boiler_wwactivated | |
Logano GB212 | boiler | 170 | wwonetime | one time charging | boolean | True | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
Logano GB212 | boiler | 170 | wwdisinfecting | disinfecting | boolean | True | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
Logano GB212 | boiler | 170 | wwcharging | charging | boolean | False | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
Logano GB212 | boiler | 170 | wwrecharging | recharging | boolean | False | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
Logano GB212 | boiler | 170 | wwtempok | temperature ok | boolean | False | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
Logano GB212 | boiler | 170 | wwactive | active | boolean | False | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
Logano GB212 | boiler | 170 | ww3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
Logano GB212 | boiler | 170 | wwsetpumppower | set pump power | uint (>=0<=100) | % | False | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
Logano GB212 | boiler | 170 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | False | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
Logano GB212 | boiler | 170 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | False | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
Logano GB212 | boiler | 170 | wwstarts | starts | ulong (>=0<=65533) | False | sensor.boiler_starts | sensor.boiler_wwstarts | |
Logano GB212 | boiler | 170 | wwworkm | active time | time (>=0<=65533) | minutes | False | sensor.boiler_active_time | sensor.boiler_wwworkm |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | reset | Reset | cmd [-|maintenance|error] | True | sensor.boiler_Reset | sensor.boiler_reset | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | rettemp | return temperature | ushort (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | syspress | system pressure | uint (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | burngas | gas | boolean | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | burngas2 | gas stage 2 | boolean | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | flamecurr | flame current | ushort (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | fanwork | fan | boolean | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | ignwork | ignition | boolean | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | oilpreheat | oil preheating | boolean | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | heatingtemp | heating temperature | uint (>=0<=254) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | pumpdelay | pump delay | uint (>=0<=254) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | burnminperiod | burner min period | uint (>=0<=254) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | burnminpower | burner min power | uint (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | burnmaxpower | burner max power | uint (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | setflowtemp | set flow temperature | uint (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | setburnpow | burner set power | uint (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | selburnpow | burner selected max power | uint (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | curburnpow | burner current power | uint (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | burnstarts | burner starts | ulong (>=0<=65533) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | heatstarts | burner starts heating | ulong (>=0<=65533) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | servicecodenumber | service code number | ushort (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | emergencytemp | emergency temperature | uint (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | uptimecontrol | total operating time heat | time (>=0<=17476) | minutes | False | sensor.boiler_total_operating_time_heat | sensor.boiler_uptimecontrol |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | uptimecompheating | operating time compressor heating | time (>=0<=17476) | minutes | False | sensor.boiler_operating_time_compressor_heating | sensor.boiler_uptimecompheating |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | uptimecompcooling | operating time compressor cooling | time (>=0<=17476) | minutes | False | sensor.boiler_operating_time_compressor_cooling | sensor.boiler_uptimecompcooling |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | uptimecompww | operating time compressor dhw | time (>=0<=17476) | minutes | False | sensor.boiler_operating_time_compressor_dhw | sensor.boiler_uptimecompww |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | uptimecomppool | operating time compressor pool | time (>=0<=17476) | minutes | False | sensor.boiler_operating_time_compressor_pool | sensor.boiler_uptimecomppool |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | totalcompstarts | total compressor control starts | ulong (>=0<=65533) | False | sensor.boiler_total_compressor_control_starts | sensor.boiler_totalcompstarts | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | heatingstarts | heating control starts | ulong (>=0<=65533) | False | sensor.boiler_heating_control_starts | sensor.boiler_heatingstarts | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | coolingstarts | cooling control starts | ulong (>=0<=65533) | False | sensor.boiler_cooling_control_starts | sensor.boiler_coolingstarts | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwstarts2 | control starts2 | ulong (>=0<=65533) | False | sensor.boiler_control_starts2 | sensor.boiler_wwstarts2 | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | poolstarts | pool control starts | ulong (>=0<=65533) | False | sensor.boiler_pool_control_starts | sensor.boiler_poolstarts | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgconstotal | total energy consumption | ulong (>=0<=65533) | kWh | False | sensor.boiler_total_energy_consumption | sensor.boiler_nrgconstotal |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgconscomptotal | total energy consumption compressor | ulong (>=0<=65533) | kWh | False | sensor.boiler_total_energy_consumption_compressor | sensor.boiler_nrgconscomptotal |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgconscompheating | energy consumption compressor heating | ulong (>=0<=65533) | kWh | False | sensor.boiler_energy_consumption_compressor_heating | sensor.boiler_nrgconscompheating |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgconscompww | energy consumption compressor dhw | ulong (>=0<=65533) | kWh | False | sensor.boiler_energy_consumption_compressor_dhw | sensor.boiler_nrgconscompww |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgconscompcooling | energy consumption compressor cooling | ulong (>=0<=65533) | kWh | False | sensor.boiler_energy_consumption_compressor_cooling | sensor.boiler_nrgconscompcooling |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgconscomppool | energy consumption compressor pool | ulong (>=0<=65533) | kWh | False | sensor.boiler_energy_consumption_compressor_pool | sensor.boiler_nrgconscomppool |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxelecheatnrgconstotal | total aux elec. heater energy consumption | ulong (>=0<=65533) | kWh | False | sensor.boiler_total_aux_elec._heater_energy_consumption | sensor.boiler_auxelecheatnrgconstotal |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxelecheatnrgconsheating | aux elec. heater energy consumption heating | ulong (>=0<=65533) | kWh | False | sensor.boiler_aux_elec._heater_energy_consumption_heating | sensor.boiler_auxelecheatnrgconsheating |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxelecheatnrgconsww | aux elec. heater energy consumption dhw | ulong (>=0<=65533) | kWh | False | sensor.boiler_aux_elec._heater_energy_consumption_dhw | sensor.boiler_auxelecheatnrgconsww |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxelecheatnrgconspool | aux elec. heater energy consumption pool | ulong (>=0<=65533) | kWh | False | sensor.boiler_aux_elec._heater_energy_consumption_pool | sensor.boiler_auxelecheatnrgconspool |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgsupptotal | total energy supplied | ulong (>=0<=65533) | kWh | False | sensor.boiler_total_energy_supplied | sensor.boiler_nrgsupptotal |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgsuppheating | total energy supplied heating | ulong (>=0<=65533) | kWh | False | sensor.boiler_total_energy_supplied_heating | sensor.boiler_nrgsuppheating |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgsuppww | total energy warm supplied dhw | ulong (>=0<=65533) | kWh | False | sensor.boiler_total_energy_warm_supplied_dhw | sensor.boiler_nrgsuppww |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgsuppcooling | total energy supplied cooling | ulong (>=0<=65533) | kWh | False | sensor.boiler_total_energy_supplied_cooling | sensor.boiler_nrgsuppcooling |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgsupppool | total energy supplied pool | ulong (>=0<=65533) | kWh | False | sensor.boiler_total_energy_supplied_pool | sensor.boiler_nrgsupppool |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hppower | compressor power output | uint (>=0<=25) | kW | False | sensor.boiler_compressor_power_output | sensor.boiler_hppower |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpcompon | hp compressor | boolean | False | binary_sensor.boiler_hp_compressor | binary_sensor.boiler_hpcompon | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpactivity | compressor activity | enum [none|heating|cooling|hot water|pool|unknown|defrost] | False | sensor.boiler_compressor_activity | sensor.boiler_hpactivity | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpheatingon | hp heating | boolean | False | binary_sensor.boiler_hp_heating | binary_sensor.boiler_hpheatingon | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpcoolingon | hp cooling | boolean | False | binary_sensor.boiler_hp_cooling | binary_sensor.boiler_hpcoolingon | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpwwon | hp dhw | boolean | False | binary_sensor.boiler_hp_dhw | binary_sensor.boiler_hpwwon | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hppoolon | hp pool | boolean | False | binary_sensor.boiler_hp_pool | binary_sensor.boiler_hppoolon | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpbrinepumpspd | brine pump speed | uint (>=0<=100) | % | False | sensor.boiler_brine_pump_speed | sensor.boiler_hpbrinepumpspd |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpswitchvalve | switch valve | boolean | False | binary_sensor.boiler_switch_valve | binary_sensor.boiler_hpswitchvalve | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpcompspd | compressor speed | uint (>=0<=100) | % | False | sensor.boiler_compressor_speed | sensor.boiler_hpcompspd |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpcircspd | circulation pump speed | uint (>=0<=100) | % | False | sensor.boiler_circulation_pump_speed | sensor.boiler_hpcircspd |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpbrinein | brine in/evaporator | short (>=-3199<=3199) | C | False | sensor.boiler_brine_in/evaporator | sensor.boiler_hpbrinein |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpbrineout | brine out/condenser | short (>=-3199<=3199) | C | False | sensor.boiler_brine_out/condenser | sensor.boiler_hpbrineout |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hptc0 | heat carrier return (TC0) | short (>=-3199<=3199) | C | False | sensor.boiler_heat_carrier_return_(TC0) | sensor.boiler_hptc0 |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hptc1 | heat carrier forward (TC1) | short (>=-3199<=3199) | C | False | sensor.boiler_heat_carrier_forward_(TC1) | sensor.boiler_hptc1 |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hptc3 | condenser temperature (TC3) | short (>=-3199<=3199) | C | False | sensor.boiler_condenser_temperature_(TC3) | sensor.boiler_hptc3 |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hptr1 | compressor temperature (TR1) | short (>=-3199<=3199) | C | False | sensor.boiler_compressor_temperature_(TR1) | sensor.boiler_hptr1 |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hptr3 | refrigerant temperature liquid side (condenser output) (TR3) | short (>=-3199<=3199) | C | False | sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3) | sensor.boiler_hptr3 |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hptr4 | evaporator inlet temperature (TR4) | short (>=-3199<=3199) | C | False | sensor.boiler_evaporator_inlet_temperature_(TR4) | sensor.boiler_hptr4 |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hptr5 | compressor inlet temperature (TR5) | short (>=-3199<=3199) | C | False | sensor.boiler_compressor_inlet_temperature_(TR5) | sensor.boiler_hptr5 |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hptr6 | compressor outlet temperature (TR6) | short (>=-3199<=3199) | C | False | sensor.boiler_compressor_outlet_temperature_(TR6) | sensor.boiler_hptr6 |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hptr7 | refrigerant temperature gas side (condenser input) (TR7) | short (>=-3199<=3199) | C | False | sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7) | sensor.boiler_hptr7 |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hptl2 | air inlet temperature (TL2) | short (>=-3199<=3199) | C | False | sensor.boiler_air_inlet_temperature_(TL2) | sensor.boiler_hptl2 |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hppl1 | low pressure side temperature (PL1) | short (>=-3199<=3199) | C | False | sensor.boiler_low_pressure_side_temperature_(PL1) | sensor.boiler_hppl1 |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpph1 | high pressure side temperature (PH1) | short (>=-3199<=3199) | C | False | sensor.boiler_high_pressure_side_temperature_(PH1) | sensor.boiler_hpph1 |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | poolsettemp | pool set temperature | uint (>=0<=127) | C | True | number.boiler_pool_set_temperature | number.boiler_poolsettemp |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpin1opt | input 1 options | string | True | sensor.boiler_input_1_options | sensor.boiler_hpin1opt | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpin2opt | input 2 options | string | True | sensor.boiler_input_2_options | sensor.boiler_hpin2opt | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpin3opt | input 3 options | string | True | sensor.boiler_input_3_options | sensor.boiler_hpin3opt | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpin4opt | input 4 options | string | True | sensor.boiler_input_4_options | sensor.boiler_hpin4opt | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | maxheatcomp | heat limit compressor | enum [0 kW|2 kW|3 kW|4 kW|6 kW|9 kW] | True | select.boiler_heat_limit_compressor | select.boiler_maxheatcomp | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | maxheatheat | heat limit heating | enum [0 kW|2 kW|3 kW|4 kW|6 kW|9 kW] | True | select.boiler_heat_limit_heating | select.boiler_maxheatheat | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | maxheatdhw | heat limit dhw | enum [0 kW|2 kW|3 kW|4 kW|6 kW|9 kW] | True | select.boiler_heat_limit_dhw | select.boiler_maxheatdhw | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | mandefrost | manual defrost | boolean | True | switch.boiler_manual_defrost | switch.boiler_mandefrost | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | pvcooling | Cooling only with PV | boolean | True | switch.boiler_Cooling_only_with_PV | switch.boiler_pvcooling | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxheateronly | aux heater only | boolean | True | switch.boiler_aux_heater_only | switch.boiler_auxheateronly | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxheateroff | disable aux heater | boolean | True | switch.boiler_disable_aux_heater | switch.boiler_auxheateroff | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxheaterstatus | aux heater status | boolean | False | binary_sensor.boiler_aux_heater_status | binary_sensor.boiler_auxheaterstatus | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxheaterdelay | aux heater on delay | ushort (>=10<=1000) | K*min | True | number.boiler_aux_heater_on_delay | number.boiler_auxheaterdelay |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxmaxlimit | aux heater max limit | uint (>=0<=10) | K | True | number.boiler_aux_heater_max_limit | number.boiler_auxmaxlimit |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxlimitstart | aux heater limit start | uint (>=0<=10) | K | True | number.boiler_aux_heater_limit_start | number.boiler_auxlimitstart |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxheatrmode | aux heater mode | enum [eco|comfort] | True | select.boiler_aux_heater_mode | select.boiler_auxheatrmode | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hphystheat | on/off hyst heat | ushort (>=50<=1500) | K*min | True | number.boiler_on/off_hyst_heat | number.boiler_hphystheat |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hphystcool | on/off hyst cool | ushort (>=50<=1500) | K*min | True | number.boiler_on/off_hyst_cool | number.boiler_hphystcool |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hphystpool | on/off hyst pool | ushort (>=50<=1500) | K*min | True | number.boiler_on/off_hyst_pool | number.boiler_hphystpool |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | silentmode | silent mode | enum [off|auto|on] | True | select.boiler_silent_mode | select.boiler_silentmode | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | silentfrom | silent mode from | uint (>=0<=3810) | minutes | True | number.boiler_silent_mode_from | number.boiler_silentfrom |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | silentto | silent mode to | uint (>=0<=3810) | minutes | True | number.boiler_silent_mode_to | number.boiler_silentto |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | mintempsilent | min outside temp for silent mode | int (>=-126<=126) | C | True | number.boiler_min_outside_temp_for_silent_mode | number.boiler_mintempsilent |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | tempparmode | outside temp parallel mode | int (>=-126<=126) | C | True | number.boiler_outside_temp_parallel_mode | number.boiler_tempparmode |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxheatmix | aux heater mixing valve | int (>=-100<=100) | % | False | sensor.boiler_aux_heater_mixing_valve | sensor.boiler_auxheatmix |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | tempdiffheat | temp diff TC3/TC0 heat | uint (>=2<=10) | K | True | number.boiler_temp_diff_TC3/TC0_heat | number.boiler_tempdiffheat |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | tempdiffcool | temp diff TC3/TC0 cool | uint (>=2<=10) | K | True | number.boiler_temp_diff_TC3/TC0_cool | number.boiler_tempdiffcool |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | vpcooling | valve/pump cooling | boolean | True | switch.boiler_valve/pump_cooling | switch.boiler_vpcooling | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | heatcable | heating cable | boolean | True | switch.boiler_heating_cable | switch.boiler_heatcable | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | vc0valve | VC0 valve | boolean | True | switch.boiler_VC0_valve | switch.boiler_vc0valve | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | primepump | primary heatpump | boolean | True | switch.boiler_primary_heatpump | switch.boiler_primepump | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | primepumpmod | primary heatpump modulation | uint (>=0<=100) | % | True | number.boiler_primary_heatpump_modulation | number.boiler_primepumpmod |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hp3way | 3-way valve | boolean | True | switch.boiler_3-way_valve | switch.boiler_hp3way | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | elheatstep1 | el. heater step 1 | boolean | True | switch.boiler_el._heater_step_1 | switch.boiler_elheatstep1 | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | elheatstep2 | el. heater step 2 | boolean | True | switch.boiler_el._heater_step_2 | switch.boiler_elheatstep2 | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | elheatstep3 | el. heater step 3 | boolean | True | switch.boiler_el._heater_step_3 | switch.boiler_elheatstep3 | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwalternatingop | alternating operation | boolean | True | switch.boiler_alternating_operation | switch.boiler_wwalternatingop | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwaltopprioheat | prioritise heating during dhw | uint (>=20<=120) | minutes | True | number.boiler_prioritise_heating_during_dhw | number.boiler_wwaltopprioheat |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwaltopprioww | prioritise dhw during heating | uint (>=30<=120) | minutes | True | number.boiler_prioritise_dhw_during_heating | number.boiler_wwaltopprioww |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwcomfoff | comfort switch off | uint (>=15<=65) | C | True | number.boiler_comfort_switch_off | number.boiler_wwcomfoff |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwecooff | eco switch off | uint (>=15<=65) | C | True | number.boiler_eco_switch_off | number.boiler_wwecooff |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwecoplusoff | eco+ switch off | uint (>=48<=63) | C | True | number.boiler_eco+_switch_off | number.boiler_wwecoplusoff |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpcircpumpww | circulation pump available during dhw | boolean | True | switch.boiler_circulation_pump_available_during_dhw | switch.boiler_hpcircpumpww | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwtapactivated | turn on/off | boolean | True | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwsettemp | set temperature | uint (>=0<=254) | C | False | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwseltemp | selected temperature | uint (>=0<=254) | C | True | number.boiler_selected_temperature | number.boiler_wwseltemp |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | True | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | False | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | True | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | False | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwtype | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_type | sensor.boiler_wwtype | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwcomfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_comfort | select.boiler_wwcomfort | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwcomfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | True | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwchargeoptimization | charge optimization | boolean | True | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwmaxpower | max power | uint (>=0<=254) | % | True | number.boiler_max_power | number.boiler_wwmaxpower |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwmaxtemp | maximum temperature | uint (>=0<=70) | C | True | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwcircpump | circulation pump available | boolean | True | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwchargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwdisinfectiontemp | disinfection temperature | uint (>=0<=254) | C | True | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwcircmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwcirc | circulation active | boolean | True | switch.boiler_circulation_active | switch.boiler_wwcirc | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | False | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwactivated | activated | boolean | True | switch.boiler_activated | switch.boiler_wwactivated | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwonetime | one time charging | boolean | True | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwdisinfecting | disinfecting | boolean | True | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwcharging | charging | boolean | False | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwrecharging | recharging | boolean | False | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwtempok | temperature ok | boolean | False | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwactive | active | boolean | False | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | ww3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwsetpumppower | set pump power | uint (>=0<=100) | % | False | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | False | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | False | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwstarts | starts | ulong (>=0<=65533) | False | sensor.boiler_starts | sensor.boiler_wwstarts | |
Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwworkm | active time | time (>=0<=65533) | minutes | False | sensor.boiler_active_time | sensor.boiler_wwworkm |
Geo 5xx | boiler | 173 | reset | Reset | cmd [-|maintenance|error] | True | sensor.boiler_Reset | sensor.boiler_reset | |
Geo 5xx | boiler | 173 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
Geo 5xx | boiler | 173 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
Geo 5xx | boiler | 173 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
Geo 5xx | boiler | 173 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
Geo 5xx | boiler | 173 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
Geo 5xx | boiler | 173 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
Geo 5xx | boiler | 173 | rettemp | return temperature | ushort (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
Geo 5xx | boiler | 173 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
Geo 5xx | boiler | 173 | syspress | system pressure | uint (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
Geo 5xx | boiler | 173 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
Geo 5xx | boiler | 173 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
Geo 5xx | boiler | 173 | burngas | gas | boolean | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
Geo 5xx | boiler | 173 | burngas2 | gas stage 2 | boolean | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
Geo 5xx | boiler | 173 | flamecurr | flame current | ushort (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr |
Geo 5xx | boiler | 173 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
Geo 5xx | boiler | 173 | fanwork | fan | boolean | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
Geo 5xx | boiler | 173 | ignwork | ignition | boolean | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
Geo 5xx | boiler | 173 | oilpreheat | oil preheating | boolean | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
Geo 5xx | boiler | 173 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
Geo 5xx | boiler | 173 | heatingtemp | heating temperature | uint (>=0<=254) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
Geo 5xx | boiler | 173 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
Geo 5xx | boiler | 173 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
Geo 5xx | boiler | 173 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
Geo 5xx | boiler | 173 | pumpdelay | pump delay | uint (>=0<=254) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
Geo 5xx | boiler | 173 | burnminperiod | burner min period | uint (>=0<=254) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod |
Geo 5xx | boiler | 173 | burnminpower | burner min power | uint (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower |
Geo 5xx | boiler | 173 | burnmaxpower | burner max power | uint (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower |
Geo 5xx | boiler | 173 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
Geo 5xx | boiler | 173 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
Geo 5xx | boiler | 173 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
Geo 5xx | boiler | 173 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
Geo 5xx | boiler | 173 | setflowtemp | set flow temperature | uint (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
Geo 5xx | boiler | 173 | setburnpow | burner set power | uint (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
Geo 5xx | boiler | 173 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
Geo 5xx | boiler | 173 | selburnpow | burner selected max power | uint (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
Geo 5xx | boiler | 173 | curburnpow | burner current power | uint (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
Geo 5xx | boiler | 173 | burnstarts | burner starts | ulong (>=0<=65533) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
Geo 5xx | boiler | 173 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
Geo 5xx | boiler | 173 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
Geo 5xx | boiler | 173 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
Geo 5xx | boiler | 173 | heatstarts | burner starts heating | ulong (>=0<=65533) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
Geo 5xx | boiler | 173 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
Geo 5xx | boiler | 173 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
Geo 5xx | boiler | 173 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
Geo 5xx | boiler | 173 | servicecodenumber | service code number | ushort (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
Geo 5xx | boiler | 173 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
Geo 5xx | boiler | 173 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
Geo 5xx | boiler | 173 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
Geo 5xx | boiler | 173 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
Geo 5xx | boiler | 173 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
Geo 5xx | boiler | 173 | emergencytemp | emergency temperature | uint (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
Geo 5xx | boiler | 173 | uptimecontrol | total operating time heat | time (>=0<=17476) | minutes | False | sensor.boiler_total_operating_time_heat | sensor.boiler_uptimecontrol |
Geo 5xx | boiler | 173 | uptimecompheating | operating time compressor heating | time (>=0<=17476) | minutes | False | sensor.boiler_operating_time_compressor_heating | sensor.boiler_uptimecompheating |
Geo 5xx | boiler | 173 | uptimecompcooling | operating time compressor cooling | time (>=0<=17476) | minutes | False | sensor.boiler_operating_time_compressor_cooling | sensor.boiler_uptimecompcooling |
Geo 5xx | boiler | 173 | uptimecompww | operating time compressor dhw | time (>=0<=17476) | minutes | False | sensor.boiler_operating_time_compressor_dhw | sensor.boiler_uptimecompww |
Geo 5xx | boiler | 173 | uptimecomppool | operating time compressor pool | time (>=0<=17476) | minutes | False | sensor.boiler_operating_time_compressor_pool | sensor.boiler_uptimecomppool |
Geo 5xx | boiler | 173 | totalcompstarts | total compressor control starts | ulong (>=0<=65533) | False | sensor.boiler_total_compressor_control_starts | sensor.boiler_totalcompstarts | |
Geo 5xx | boiler | 173 | heatingstarts | heating control starts | ulong (>=0<=65533) | False | sensor.boiler_heating_control_starts | sensor.boiler_heatingstarts | |
Geo 5xx | boiler | 173 | coolingstarts | cooling control starts | ulong (>=0<=65533) | False | sensor.boiler_cooling_control_starts | sensor.boiler_coolingstarts | |
Geo 5xx | boiler | 173 | wwstarts2 | control starts2 | ulong (>=0<=65533) | False | sensor.boiler_control_starts2 | sensor.boiler_wwstarts2 | |
Geo 5xx | boiler | 173 | poolstarts | pool control starts | ulong (>=0<=65533) | False | sensor.boiler_pool_control_starts | sensor.boiler_poolstarts | |
Geo 5xx | boiler | 173 | nrgconstotal | total energy consumption | ulong (>=0<=65533) | kWh | False | sensor.boiler_total_energy_consumption | sensor.boiler_nrgconstotal |
Geo 5xx | boiler | 173 | nrgconscomptotal | total energy consumption compressor | ulong (>=0<=65533) | kWh | False | sensor.boiler_total_energy_consumption_compressor | sensor.boiler_nrgconscomptotal |
Geo 5xx | boiler | 173 | nrgconscompheating | energy consumption compressor heating | ulong (>=0<=65533) | kWh | False | sensor.boiler_energy_consumption_compressor_heating | sensor.boiler_nrgconscompheating |
Geo 5xx | boiler | 173 | nrgconscompww | energy consumption compressor dhw | ulong (>=0<=65533) | kWh | False | sensor.boiler_energy_consumption_compressor_dhw | sensor.boiler_nrgconscompww |
Geo 5xx | boiler | 173 | nrgconscompcooling | energy consumption compressor cooling | ulong (>=0<=65533) | kWh | False | sensor.boiler_energy_consumption_compressor_cooling | sensor.boiler_nrgconscompcooling |
Geo 5xx | boiler | 173 | nrgconscomppool | energy consumption compressor pool | ulong (>=0<=65533) | kWh | False | sensor.boiler_energy_consumption_compressor_pool | sensor.boiler_nrgconscomppool |
Geo 5xx | boiler | 173 | auxelecheatnrgconstotal | total aux elec. heater energy consumption | ulong (>=0<=65533) | kWh | False | sensor.boiler_total_aux_elec._heater_energy_consumption | sensor.boiler_auxelecheatnrgconstotal |
Geo 5xx | boiler | 173 | auxelecheatnrgconsheating | aux elec. heater energy consumption heating | ulong (>=0<=65533) | kWh | False | sensor.boiler_aux_elec._heater_energy_consumption_heating | sensor.boiler_auxelecheatnrgconsheating |
Geo 5xx | boiler | 173 | auxelecheatnrgconsww | aux elec. heater energy consumption dhw | ulong (>=0<=65533) | kWh | False | sensor.boiler_aux_elec._heater_energy_consumption_dhw | sensor.boiler_auxelecheatnrgconsww |
Geo 5xx | boiler | 173 | auxelecheatnrgconspool | aux elec. heater energy consumption pool | ulong (>=0<=65533) | kWh | False | sensor.boiler_aux_elec._heater_energy_consumption_pool | sensor.boiler_auxelecheatnrgconspool |
Geo 5xx | boiler | 173 | nrgsupptotal | total energy supplied | ulong (>=0<=65533) | kWh | False | sensor.boiler_total_energy_supplied | sensor.boiler_nrgsupptotal |
Geo 5xx | boiler | 173 | nrgsuppheating | total energy supplied heating | ulong (>=0<=65533) | kWh | False | sensor.boiler_total_energy_supplied_heating | sensor.boiler_nrgsuppheating |
Geo 5xx | boiler | 173 | nrgsuppww | total energy warm supplied dhw | ulong (>=0<=65533) | kWh | False | sensor.boiler_total_energy_warm_supplied_dhw | sensor.boiler_nrgsuppww |
Geo 5xx | boiler | 173 | nrgsuppcooling | total energy supplied cooling | ulong (>=0<=65533) | kWh | False | sensor.boiler_total_energy_supplied_cooling | sensor.boiler_nrgsuppcooling |
Geo 5xx | boiler | 173 | nrgsupppool | total energy supplied pool | ulong (>=0<=65533) | kWh | False | sensor.boiler_total_energy_supplied_pool | sensor.boiler_nrgsupppool |
Geo 5xx | boiler | 173 | hppower | compressor power output | uint (>=0<=25) | kW | False | sensor.boiler_compressor_power_output | sensor.boiler_hppower |
Geo 5xx | boiler | 173 | hpcompon | hp compressor | boolean | False | binary_sensor.boiler_hp_compressor | binary_sensor.boiler_hpcompon | |
Geo 5xx | boiler | 173 | hpactivity | compressor activity | enum [none|heating|cooling|hot water|pool|unknown|defrost] | False | sensor.boiler_compressor_activity | sensor.boiler_hpactivity | |
Geo 5xx | boiler | 173 | hpheatingon | hp heating | boolean | False | binary_sensor.boiler_hp_heating | binary_sensor.boiler_hpheatingon | |
Geo 5xx | boiler | 173 | hpcoolingon | hp cooling | boolean | False | binary_sensor.boiler_hp_cooling | binary_sensor.boiler_hpcoolingon | |
Geo 5xx | boiler | 173 | hpwwon | hp dhw | boolean | False | binary_sensor.boiler_hp_dhw | binary_sensor.boiler_hpwwon | |
Geo 5xx | boiler | 173 | hppoolon | hp pool | boolean | False | binary_sensor.boiler_hp_pool | binary_sensor.boiler_hppoolon | |
Geo 5xx | boiler | 173 | hpbrinepumpspd | brine pump speed | uint (>=0<=100) | % | False | sensor.boiler_brine_pump_speed | sensor.boiler_hpbrinepumpspd |
Geo 5xx | boiler | 173 | hpswitchvalve | switch valve | boolean | False | binary_sensor.boiler_switch_valve | binary_sensor.boiler_hpswitchvalve | |
Geo 5xx | boiler | 173 | hpcompspd | compressor speed | uint (>=0<=100) | % | False | sensor.boiler_compressor_speed | sensor.boiler_hpcompspd |
Geo 5xx | boiler | 173 | hpcircspd | circulation pump speed | uint (>=0<=100) | % | False | sensor.boiler_circulation_pump_speed | sensor.boiler_hpcircspd |
Geo 5xx | boiler | 173 | hpbrinein | brine in/evaporator | short (>=-3199<=3199) | C | False | sensor.boiler_brine_in/evaporator | sensor.boiler_hpbrinein |
Geo 5xx | boiler | 173 | hpbrineout | brine out/condenser | short (>=-3199<=3199) | C | False | sensor.boiler_brine_out/condenser | sensor.boiler_hpbrineout |
Geo 5xx | boiler | 173 | hptc0 | heat carrier return (TC0) | short (>=-3199<=3199) | C | False | sensor.boiler_heat_carrier_return_(TC0) | sensor.boiler_hptc0 |
Geo 5xx | boiler | 173 | hptc1 | heat carrier forward (TC1) | short (>=-3199<=3199) | C | False | sensor.boiler_heat_carrier_forward_(TC1) | sensor.boiler_hptc1 |
Geo 5xx | boiler | 173 | hptc3 | condenser temperature (TC3) | short (>=-3199<=3199) | C | False | sensor.boiler_condenser_temperature_(TC3) | sensor.boiler_hptc3 |
Geo 5xx | boiler | 173 | hptr1 | compressor temperature (TR1) | short (>=-3199<=3199) | C | False | sensor.boiler_compressor_temperature_(TR1) | sensor.boiler_hptr1 |
Geo 5xx | boiler | 173 | hptr3 | refrigerant temperature liquid side (condenser output) (TR3) | short (>=-3199<=3199) | C | False | sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3) | sensor.boiler_hptr3 |
Geo 5xx | boiler | 173 | hptr4 | evaporator inlet temperature (TR4) | short (>=-3199<=3199) | C | False | sensor.boiler_evaporator_inlet_temperature_(TR4) | sensor.boiler_hptr4 |
Geo 5xx | boiler | 173 | hptr5 | compressor inlet temperature (TR5) | short (>=-3199<=3199) | C | False | sensor.boiler_compressor_inlet_temperature_(TR5) | sensor.boiler_hptr5 |
Geo 5xx | boiler | 173 | hptr6 | compressor outlet temperature (TR6) | short (>=-3199<=3199) | C | False | sensor.boiler_compressor_outlet_temperature_(TR6) | sensor.boiler_hptr6 |
Geo 5xx | boiler | 173 | hptr7 | refrigerant temperature gas side (condenser input) (TR7) | short (>=-3199<=3199) | C | False | sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7) | sensor.boiler_hptr7 |
Geo 5xx | boiler | 173 | hptl2 | air inlet temperature (TL2) | short (>=-3199<=3199) | C | False | sensor.boiler_air_inlet_temperature_(TL2) | sensor.boiler_hptl2 |
Geo 5xx | boiler | 173 | hppl1 | low pressure side temperature (PL1) | short (>=-3199<=3199) | C | False | sensor.boiler_low_pressure_side_temperature_(PL1) | sensor.boiler_hppl1 |
Geo 5xx | boiler | 173 | hpph1 | high pressure side temperature (PH1) | short (>=-3199<=3199) | C | False | sensor.boiler_high_pressure_side_temperature_(PH1) | sensor.boiler_hpph1 |
Geo 5xx | boiler | 173 | poolsettemp | pool set temperature | uint (>=0<=127) | C | True | number.boiler_pool_set_temperature | number.boiler_poolsettemp |
Geo 5xx | boiler | 173 | hpin1opt | input 1 options | string | True | sensor.boiler_input_1_options | sensor.boiler_hpin1opt | |
Geo 5xx | boiler | 173 | hpin2opt | input 2 options | string | True | sensor.boiler_input_2_options | sensor.boiler_hpin2opt | |
Geo 5xx | boiler | 173 | hpin3opt | input 3 options | string | True | sensor.boiler_input_3_options | sensor.boiler_hpin3opt | |
Geo 5xx | boiler | 173 | hpin4opt | input 4 options | string | True | sensor.boiler_input_4_options | sensor.boiler_hpin4opt | |
Geo 5xx | boiler | 173 | maxheatcomp | heat limit compressor | enum [0 kW|2 kW|3 kW|4 kW|6 kW|9 kW] | True | select.boiler_heat_limit_compressor | select.boiler_maxheatcomp | |
Geo 5xx | boiler | 173 | maxheatheat | heat limit heating | enum [0 kW|2 kW|3 kW|4 kW|6 kW|9 kW] | True | select.boiler_heat_limit_heating | select.boiler_maxheatheat | |
Geo 5xx | boiler | 173 | maxheatdhw | heat limit dhw | enum [0 kW|2 kW|3 kW|4 kW|6 kW|9 kW] | True | select.boiler_heat_limit_dhw | select.boiler_maxheatdhw | |
Geo 5xx | boiler | 173 | mandefrost | manual defrost | boolean | True | switch.boiler_manual_defrost | switch.boiler_mandefrost | |
Geo 5xx | boiler | 173 | pvcooling | Cooling only with PV | boolean | True | switch.boiler_Cooling_only_with_PV | switch.boiler_pvcooling | |
Geo 5xx | boiler | 173 | auxheateronly | aux heater only | boolean | True | switch.boiler_aux_heater_only | switch.boiler_auxheateronly | |
Geo 5xx | boiler | 173 | auxheateroff | disable aux heater | boolean | True | switch.boiler_disable_aux_heater | switch.boiler_auxheateroff | |
Geo 5xx | boiler | 173 | auxheaterstatus | aux heater status | boolean | False | binary_sensor.boiler_aux_heater_status | binary_sensor.boiler_auxheaterstatus | |
Geo 5xx | boiler | 173 | auxheaterdelay | aux heater on delay | ushort (>=10<=1000) | K*min | True | number.boiler_aux_heater_on_delay | number.boiler_auxheaterdelay |
Geo 5xx | boiler | 173 | auxmaxlimit | aux heater max limit | uint (>=0<=10) | K | True | number.boiler_aux_heater_max_limit | number.boiler_auxmaxlimit |
Geo 5xx | boiler | 173 | auxlimitstart | aux heater limit start | uint (>=0<=10) | K | True | number.boiler_aux_heater_limit_start | number.boiler_auxlimitstart |
Geo 5xx | boiler | 173 | auxheatrmode | aux heater mode | enum [eco|comfort] | True | select.boiler_aux_heater_mode | select.boiler_auxheatrmode | |
Geo 5xx | boiler | 173 | hphystheat | on/off hyst heat | ushort (>=50<=1500) | K*min | True | number.boiler_on/off_hyst_heat | number.boiler_hphystheat |
Geo 5xx | boiler | 173 | hphystcool | on/off hyst cool | ushort (>=50<=1500) | K*min | True | number.boiler_on/off_hyst_cool | number.boiler_hphystcool |
Geo 5xx | boiler | 173 | hphystpool | on/off hyst pool | ushort (>=50<=1500) | K*min | True | number.boiler_on/off_hyst_pool | number.boiler_hphystpool |
Geo 5xx | boiler | 173 | silentmode | silent mode | enum [off|auto|on] | True | select.boiler_silent_mode | select.boiler_silentmode | |
Geo 5xx | boiler | 173 | silentfrom | silent mode from | uint (>=0<=3810) | minutes | True | number.boiler_silent_mode_from | number.boiler_silentfrom |
Geo 5xx | boiler | 173 | silentto | silent mode to | uint (>=0<=3810) | minutes | True | number.boiler_silent_mode_to | number.boiler_silentto |
Geo 5xx | boiler | 173 | mintempsilent | min outside temp for silent mode | int (>=-126<=126) | C | True | number.boiler_min_outside_temp_for_silent_mode | number.boiler_mintempsilent |
Geo 5xx | boiler | 173 | tempparmode | outside temp parallel mode | int (>=-126<=126) | C | True | number.boiler_outside_temp_parallel_mode | number.boiler_tempparmode |
Geo 5xx | boiler | 173 | auxheatmix | aux heater mixing valve | int (>=-100<=100) | % | False | sensor.boiler_aux_heater_mixing_valve | sensor.boiler_auxheatmix |
Geo 5xx | boiler | 173 | tempdiffheat | temp diff TC3/TC0 heat | uint (>=2<=10) | K | True | number.boiler_temp_diff_TC3/TC0_heat | number.boiler_tempdiffheat |
Geo 5xx | boiler | 173 | tempdiffcool | temp diff TC3/TC0 cool | uint (>=2<=10) | K | True | number.boiler_temp_diff_TC3/TC0_cool | number.boiler_tempdiffcool |
Geo 5xx | boiler | 173 | vpcooling | valve/pump cooling | boolean | True | switch.boiler_valve/pump_cooling | switch.boiler_vpcooling | |
Geo 5xx | boiler | 173 | heatcable | heating cable | boolean | True | switch.boiler_heating_cable | switch.boiler_heatcable | |
Geo 5xx | boiler | 173 | vc0valve | VC0 valve | boolean | True | switch.boiler_VC0_valve | switch.boiler_vc0valve | |
Geo 5xx | boiler | 173 | primepump | primary heatpump | boolean | True | switch.boiler_primary_heatpump | switch.boiler_primepump | |
Geo 5xx | boiler | 173 | primepumpmod | primary heatpump modulation | uint (>=0<=100) | % | True | number.boiler_primary_heatpump_modulation | number.boiler_primepumpmod |
Geo 5xx | boiler | 173 | hp3way | 3-way valve | boolean | True | switch.boiler_3-way_valve | switch.boiler_hp3way | |
Geo 5xx | boiler | 173 | elheatstep1 | el. heater step 1 | boolean | True | switch.boiler_el._heater_step_1 | switch.boiler_elheatstep1 | |
Geo 5xx | boiler | 173 | elheatstep2 | el. heater step 2 | boolean | True | switch.boiler_el._heater_step_2 | switch.boiler_elheatstep2 | |
Geo 5xx | boiler | 173 | elheatstep3 | el. heater step 3 | boolean | True | switch.boiler_el._heater_step_3 | switch.boiler_elheatstep3 | |
Geo 5xx | boiler | 173 | wwalternatingop | alternating operation | boolean | True | switch.boiler_alternating_operation | switch.boiler_wwalternatingop | |
Geo 5xx | boiler | 173 | wwaltopprioheat | prioritise heating during dhw | uint (>=20<=120) | minutes | True | number.boiler_prioritise_heating_during_dhw | number.boiler_wwaltopprioheat |
Geo 5xx | boiler | 173 | wwaltopprioww | prioritise dhw during heating | uint (>=30<=120) | minutes | True | number.boiler_prioritise_dhw_during_heating | number.boiler_wwaltopprioww |
Geo 5xx | boiler | 173 | wwcomfoff | comfort switch off | uint (>=15<=65) | C | True | number.boiler_comfort_switch_off | number.boiler_wwcomfoff |
Geo 5xx | boiler | 173 | wwecooff | eco switch off | uint (>=15<=65) | C | True | number.boiler_eco_switch_off | number.boiler_wwecooff |
Geo 5xx | boiler | 173 | wwecoplusoff | eco+ switch off | uint (>=48<=63) | C | True | number.boiler_eco+_switch_off | number.boiler_wwecoplusoff |
Geo 5xx | boiler | 173 | hpcircpumpww | circulation pump available during dhw | boolean | True | switch.boiler_circulation_pump_available_during_dhw | switch.boiler_hpcircpumpww | |
Geo 5xx | boiler | 173 | wwtapactivated | turn on/off | boolean | True | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
Geo 5xx | boiler | 173 | wwsettemp | set temperature | uint (>=0<=254) | C | False | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
Geo 5xx | boiler | 173 | wwseltemp | selected temperature | uint (>=0<=254) | C | True | number.boiler_selected_temperature | number.boiler_wwseltemp |
Geo 5xx | boiler | 173 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | True | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
Geo 5xx | boiler | 173 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | False | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
Geo 5xx | boiler | 173 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | True | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
Geo 5xx | boiler | 173 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | False | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
Geo 5xx | boiler | 173 | wwtype | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_type | sensor.boiler_wwtype | |
Geo 5xx | boiler | 173 | wwcomfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_comfort | select.boiler_wwcomfort | |
Geo 5xx | boiler | 173 | wwcomfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
Geo 5xx | boiler | 173 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | True | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
Geo 5xx | boiler | 173 | wwchargeoptimization | charge optimization | boolean | True | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
Geo 5xx | boiler | 173 | wwmaxpower | max power | uint (>=0<=254) | % | True | number.boiler_max_power | number.boiler_wwmaxpower |
Geo 5xx | boiler | 173 | wwmaxtemp | maximum temperature | uint (>=0<=70) | C | True | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
Geo 5xx | boiler | 173 | wwcircpump | circulation pump available | boolean | True | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
Geo 5xx | boiler | 173 | wwchargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
Geo 5xx | boiler | 173 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
Geo 5xx | boiler | 173 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
Geo 5xx | boiler | 173 | wwdisinfectiontemp | disinfection temperature | uint (>=0<=254) | C | True | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
Geo 5xx | boiler | 173 | wwcircmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
Geo 5xx | boiler | 173 | wwcirc | circulation active | boolean | True | switch.boiler_circulation_active | switch.boiler_wwcirc | |
Geo 5xx | boiler | 173 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
Geo 5xx | boiler | 173 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
Geo 5xx | boiler | 173 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | False | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
Geo 5xx | boiler | 173 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
Geo 5xx | boiler | 173 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
Geo 5xx | boiler | 173 | wwactivated | activated | boolean | True | switch.boiler_activated | switch.boiler_wwactivated | |
Geo 5xx | boiler | 173 | wwonetime | one time charging | boolean | True | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
Geo 5xx | boiler | 173 | wwdisinfecting | disinfecting | boolean | True | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
Geo 5xx | boiler | 173 | wwcharging | charging | boolean | False | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
Geo 5xx | boiler | 173 | wwrecharging | recharging | boolean | False | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
Geo 5xx | boiler | 173 | wwtempok | temperature ok | boolean | False | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
Geo 5xx | boiler | 173 | wwactive | active | boolean | False | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
Geo 5xx | boiler | 173 | ww3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
Geo 5xx | boiler | 173 | wwsetpumppower | set pump power | uint (>=0<=100) | % | False | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
Geo 5xx | boiler | 173 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | False | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
Geo 5xx | boiler | 173 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | False | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
Geo 5xx | boiler | 173 | wwstarts | starts | ulong (>=0<=65533) | False | sensor.boiler_starts | sensor.boiler_wwstarts | |
Geo 5xx | boiler | 173 | wwworkm | active time | time (>=0<=65533) | minutes | False | sensor.boiler_active_time | sensor.boiler_wwworkm |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | reset | Reset | cmd [-|maintenance|error] | True | sensor.boiler_Reset | sensor.boiler_reset | |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | rettemp | return temperature | ushort (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | syspress | system pressure | uint (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | burngas | gas | boolean | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | burngas2 | gas stage 2 | boolean | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | flamecurr | flame current | ushort (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | fanwork | fan | boolean | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | ignwork | ignition | boolean | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | oilpreheat | oil preheating | boolean | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | heatingtemp | heating temperature | uint (>=0<=254) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | pumpdelay | pump delay | uint (>=0<=254) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | burnminperiod | burner min period | uint (>=0<=254) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | burnminpower | burner min power | uint (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | burnmaxpower | burner max power | uint (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | setflowtemp | set flow temperature | uint (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | setburnpow | burner set power | uint (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | selburnpow | burner selected max power | uint (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | curburnpow | burner current power | uint (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | burnstarts | burner starts | ulong (>=0<=65533) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | heatstarts | burner starts heating | ulong (>=0<=65533) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | servicecodenumber | service code number | ushort (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | emergencytemp | emergency temperature | uint (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwtapactivated | turn on/off | boolean | True | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwsettemp | set temperature | uint (>=0<=254) | C | False | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwseltemp | selected temperature | uint (>=0<=254) | C | True | number.boiler_selected_temperature | number.boiler_wwseltemp |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | True | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | False | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | True | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | False | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwtype | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_type | sensor.boiler_wwtype | |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwcomfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_comfort | select.boiler_wwcomfort | |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwcomfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | True | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwchargeoptimization | charge optimization | boolean | True | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwmaxpower | max power | uint (>=0<=254) | % | True | number.boiler_max_power | number.boiler_wwmaxpower |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwmaxtemp | maximum temperature | uint (>=0<=70) | C | True | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwcircpump | circulation pump available | boolean | True | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwchargetype | charging type | enum [chargepump|3-way valve] | False | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwdisinfectiontemp | disinfection temperature | uint (>=0<=254) | C | True | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwcircmode | circulation pump mode | enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] | True | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwcirc | circulation active | boolean | True | switch.boiler_circulation_active | switch.boiler_wwcirc | |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | False | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | False | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwactivated | activated | boolean | True | switch.boiler_activated | switch.boiler_wwactivated | |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwonetime | one time charging | boolean | True | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwdisinfecting | disinfecting | boolean | True | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwcharging | charging | boolean | False | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwrecharging | recharging | boolean | False | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwtempok | temperature ok | boolean | False | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwactive | active | boolean | False | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | ww3wayvalve | 3-way valve active | boolean | False | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwsetpumppower | set pump power | uint (>=0<=100) | % | False | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | False | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | False | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwstarts | starts | ulong (>=0<=65533) | False | sensor.boiler_starts | sensor.boiler_wwstarts | |
Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwworkm | active time | time (>=0<=65533) | minutes | False | sensor.boiler_active_time | sensor.boiler_wwworkm |
Logamax U122/Cerapur | boiler | 203 | reset | Reset | cmd [-|maintenance|error] | True | sensor.boiler_Reset | sensor.boiler_reset | |
Logamax U122/Cerapur | boiler | 203 | heatingactive | heating active | boolean | False | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
Logamax U122/Cerapur | boiler | 203 | tapwateractive | tapwater active | boolean | False | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
Logamax U122/Cerapur | boiler | 203 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | True | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
Logamax U122/Cerapur | boiler | 203 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | False | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
Logamax U122/Cerapur | boiler | 203 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | False | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
Logamax U122/Cerapur | boiler | 203 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | False | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
Logamax U122/Cerapur | boiler | 203 | rettemp | return temperature | ushort (>=0<=3199) | C | False | sensor.boiler_return_temperature | sensor.boiler_rettemp |
Logamax U122/Cerapur | boiler | 203 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | False | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
Logamax U122/Cerapur | boiler | 203 | syspress | system pressure | uint (>=0<=25) | bar | False | sensor.boiler_system_pressure | sensor.boiler_syspress |
Logamax U122/Cerapur | boiler | 203 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | False | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
Logamax U122/Cerapur | boiler | 203 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | False | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
Logamax U122/Cerapur | boiler | 203 | burngas | gas | boolean | False | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
Logamax U122/Cerapur | boiler | 203 | burngas2 | gas stage 2 | boolean | False | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
Logamax U122/Cerapur | boiler | 203 | flamecurr | flame current | ushort (>=0<=3199) | µA | False | sensor.boiler_flame_current | sensor.boiler_flamecurr |
Logamax U122/Cerapur | boiler | 203 | heatingpump | heating pump | boolean | False | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
Logamax U122/Cerapur | boiler | 203 | fanwork | fan | boolean | False | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
Logamax U122/Cerapur | boiler | 203 | ignwork | ignition | boolean | False | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
Logamax U122/Cerapur | boiler | 203 | oilpreheat | oil preheating | boolean | False | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
Logamax U122/Cerapur | boiler | 203 | heatingactivated | heating activated | boolean | True | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
Logamax U122/Cerapur | boiler | 203 | heatingtemp | heating temperature | uint (>=0<=254) | C | True | number.boiler_heating_temperature | number.boiler_heatingtemp |
Logamax U122/Cerapur | boiler | 203 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | True | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
Logamax U122/Cerapur | boiler | 203 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | True | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
Logamax U122/Cerapur | boiler | 203 | pumpmode | boiler pump mode | enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] | True | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
Logamax U122/Cerapur | boiler | 203 | pumpdelay | pump delay | uint (>=0<=254) | minutes | True | number.boiler_pump_delay | number.boiler_pumpdelay |
Logamax U122/Cerapur | boiler | 203 | burnminperiod | burner min period | uint (>=0<=254) | minutes | True | number.boiler_burner_min_period | number.boiler_burnminperiod |
Logamax U122/Cerapur | boiler | 203 | burnminpower | burner min power | uint (>=0<=100) | % | True | number.boiler_burner_min_power | number.boiler_burnminpower |
Logamax U122/Cerapur | boiler | 203 | burnmaxpower | burner max power | uint (>=0<=254) | % | True | number.boiler_burner_max_power | number.boiler_burnmaxpower |
Logamax U122/Cerapur | boiler | 203 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
Logamax U122/Cerapur | boiler | 203 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | True | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
Logamax U122/Cerapur | boiler | 203 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | True | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
Logamax U122/Cerapur | boiler | 203 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | True | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
Logamax U122/Cerapur | boiler | 203 | setflowtemp | set flow temperature | uint (>=0<=254) | C | False | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
Logamax U122/Cerapur | boiler | 203 | setburnpow | burner set power | uint (>=0<=100) | % | False | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
Logamax U122/Cerapur | boiler | 203 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | False | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
Logamax U122/Cerapur | boiler | 203 | selburnpow | burner selected max power | uint (>=0<=254) | % | True | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
Logamax U122/Cerapur | boiler | 203 | curburnpow | burner current power | uint (>=0<=100) | % | False | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
Logamax U122/Cerapur | boiler | 203 | burnstarts | burner starts | ulong (>=0<=65533) | False | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
Logamax U122/Cerapur | boiler | 203 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
Logamax U122/Cerapur | boiler | 203 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | False | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
Logamax U122/Cerapur | boiler | 203 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
Logamax U122/Cerapur | boiler | 203 | heatstarts | burner starts heating | ulong (>=0<=65533) | False | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
Logamax U122/Cerapur | boiler | 203 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | False | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
Logamax U122/Cerapur | boiler | 203 | lastcode | last error code | string | False | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
Logamax U122/Cerapur | boiler | 203 | servicecode | service code | string | False | sensor.boiler_service_code | sensor.boiler_servicecode | |
Logamax U122/Cerapur | boiler | 203 | servicecodenumber | service code number | ushort (>=0<=31999) | False | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
Logamax U122/Cerapur | boiler | 203 | maintenancemessage | maintenance message | string | False | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
Logamax U122/Cerapur | boiler | 203 | maintenance | maintenance scheduled | enum [off|time|date|manual] | True | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
Logamax U122/Cerapur | boiler | 203 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | True | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
Logamax U122/Cerapur | boiler | 203 | maintenancedate | next maintenance date | string | True | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
Logamax U122/Cerapur | boiler | 203 | emergencyops | emergency operation | boolean | True | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
Logamax U122/Cerapur | boiler | 203 | emergencytemp | emergency temperature | uint (>=15<=70) | C | True | number.boiler_emergency_temperature | number.boiler_emergencytemp |
Logamax U122/Cerapur | boiler | 203 | wwtapactivated | turn on/off | boolean | True | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
Logamax U122/Cerapur | boiler | 203 | wwsettemp | set temperature | uint (>=0<=254) | C | False | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
Logamax U122/Cerapur | boiler | 203 | wwseltemp | selected temperature | uint (>=0<=254) | C | True | number.boiler_selected_temperature | number.boiler_wwseltemp |
Logamax U122/Cerapur | boiler | 203 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | True | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
Logamax U122/Cerapur | boiler | 203 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | False | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
Logamax U122/Cerapur | boiler | 203 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | True | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
Logamax U122/Cerapur | boiler | 203 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | False | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
Logamax U122/Cerapur | boiler | 203 | wwtype | type | enum [off|flow|buffered flow|buffer|layered buffer] | False | sensor.boiler_type | sensor.boiler_wwtype | |
Logamax U122/Cerapur | boiler | 203 | wwcomfort | comfort | enum [hot|eco|intelligent] | True | select.boiler_comfort | select.boiler_wwcomfort | |
Logamax U122/Cerapur | boiler | 203 | wwcomfort1 | comfort mode | enum [high comfort|eco] | True | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
Logamax U122/Cerapur | boiler | 203 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | True | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
Logamax U122/Cerapur |