List of Boilers~
This is the current list of supported boilers from Buderus, Nefit, Sieger, Junkers and Bosch:
- BK13/BK15/Smartline/GB1x2i
- GB125/GB135/MC10
- Cascade CM10
- Logamax Plus GB022
- Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3
- Topline/GB162
- Cascade MCM10
- Proline
- GBx72/Trendline/Cerapur/Greenstar Si
- GB212
- GC7000F
- Logano GB125/KB195i/Logamatic MC110
- Greenstar 30Ri Compact
- Cerapur Aero
- Hybrid Heatpump
- Logano GB212
- Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i
- Geo 5xx
- Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2
- Logamax U122/Cerapur
- Ecomline Excellent
- Logamax Plus/GB192/Condens GC9000/Greenstar ErP
- Cascade MC400
- EasyControl Adapter
- Greenstar HIU
- Logamax Plus GB122/Condense 2300
Device Entities~
Notice
The boiler commands below will vary depending on boiler type/brand and system configuration Some commands will not work because they are overwritten by controller or thermostat. In this case there are thermostat commands for this setting.
this list is not complete and subject to change between versions
command | data | id | comments |
---|---|---|---|
comfort | <hot \|eco \| intelligent> | ||
flowtemp | <degrees> | Limited to heatingtemp, set by thermostat if present | |
wwsettemp | <degrees> | Only if thermostat does not manage it | |
boilhyston | <degrees> | Start burner below flowtemp (negative value), allowed range depends on boiler type | |
boilhystoff | <degrees> | Stop burner above flowtemp (positive value), allowed range depends on boiler type | |
burnperiod | <minutes> | ||
burnminpower | <%> | Changeable only for modulated burners | |
burnmaxpower | <%> | Changeable only for modulated burners | |
pumpdelay | <minutes> | ||
wwactivated | <off \| on> | ||
wwtapactivated | <off \| on> | Special function working in boiler test-mode | |
wwonetime | <off \| on> | Overwritten by some thermostats, see thermostat commands | |
wwcircpump | <off \| on> | ||
wwcirc | <off \| on> | Overwritten by some thermostats, see thermostat commands | |
wwcircmode | <n> | (1=1x3min, .. 6=6x3min, 7=on) | |
wwflowtempoffset | <degrees> | Offset to boiler temperature while preparing warm water | |
wwmaxpower | <%> | Maximum power for warm water heating | |
heatingactivated | <off \| on> | Not changeable for some systems. i.g. Set by MC10 rotary control | |
heatingtemp | <degrees> | Upper limit for flowtemp, not changeable for some systems or overwritten (MC10) | |
maintenance | <off \| <hours> \| <dd.mm.yyyy> \| reset> | set maintenance to date or time or reset message | |
pumpmodmin | <%> | Changeable only for modulated pumps | |
pumpmodmax | <%> | Changeable only for modulated pumps | |
reset | <error \| maintenance> | Use reset error only if there is an active error! |