Skip to content

FAQ

How to Hardware Reset~

If you have a GPIO Button configured (enabled by default on all BBQKees boards) pressing this has different actions:

  • single press: does nothing
  • double press: re-connects the WiFi
  • hold for 10 seconds: performs a factory reset. EMS-ESP will restart in Access Point mode

Decoding EMS Telegrams~

Written by @MichaelDvP in this article:

Best overview of known telegrams is from Norberts1 and the EMS-Wiki. In general we can say:

  • measurement values are broadcasted periodical 10 sec / 1 min
  • settings are only broadcasted after a change
  • changing a setting of a device via the UI of thermostat results in a message thermostat -w-> device with only this value
  • some devices broadcast fast changing values as single values
  • measured temperatures are normally 2 bytes (SHORT) with factor 0.1 (e.g. 01 23 -> 0x0123 -> dez 291 -> 29.1°C)
  • air temperature settings are often factor 0.5 as single byte (INT) (e.g. 0x2D -> dez 45 -> 22.5°C)
  • water temperature settings are typically single byte (UINT) (e.g. 0x3C -> 60°C), differential values (hysteresis in Kelvin) are signed (INT)
  • percent settings are single byte (UINT) (0x64 -> 100%)
  • on/off states or settings can be single byte with on/off 0xFF/0x00, or 0x01/0x00 or a single bit in a byte together with 7 other states
  • times and energy is typically 3 or 4 bytes with or without factor

For different brands/devices Bosch sometimes use different expressions for the same value, Maybe changing developers or they like to make reverse engineering difficult!

If you search a setting, log the telegrams for the device (log all or watch ) and change the setting on the thermostat to different states/values. Then search for these values in the log. If you search for a measurement, log the device and view the value on the thermostat and wait for changes, note old/new values and time. Then check the log for this time stamp (or 10 sec / 1 min later) and the value within a telegram. Best to have more changes/values to be sure.

Can EMS-ESP simulate a Thermostat?~

No, but in theory it could.

As MichaelDvP points out "a thermostat is a clever electronic device. You can put in the desired room temperature and it calculates from some parameters and measurements the required flowtemp for this room temperature and sends it to the boiler. This happens in a control loop and is updated often."

And mtc716 said "A thermostat creates a heat curve that is constantly adapted to the surrounding temperatures and used to estimate which water temperature is necessary in order to bring the room temperature up. There are some good articles in the net about how to setup the heat curve correctly. The main parameters you need are "design temp" which is the heating water temp at minimal outside temp. Furthermore you need the "comfort temp" like explained before and the "temp offset" which causes a parallel shift in the heating curve."

See Smart control a heating system with HA? and thermostat emulation.